win-i16h56j2l01cps公共盘报告组王一璐word 511...

10
TEST REPORT No. : SH151100059C09 Report Date: 2015/11/10 Approved by Salvia Hu Reviewed by Leo Liu Redact by Luciana Wang Page 1 of 10 This Test Report is issued by the Company subject to its General Conditions of Service printed overleaf or available on request. Attention is drawn to the limitations of liability, indemnification and jurisdictional policies defined therein. The results shown in this Test report refer only to the sample(s) tested unless otherwise stated This test report shall not be reproduced, except in full, without written approval of the Company. 本报告按本公司所制定之通用服务条款所编制发放。请注意本报告首页背面之此条款,本公司之义务、免责、管辖权均有明确规定,该条 款也可向本公司索取。除非另有说明,本报告仅对来样负责,未经许可,不得部分复制本报告。 优联(上海)检测有限公司 United (Shanghai) Testing ServicesCo.Ltd. 地址:上海市外高桥保税区富特东三路7632栋西3200131 3/F., Building32,No.76 , Fute East 3 Road., Waigaoqiao Free Trade Zone, Shanghai, 200131 电话(Tel):+86(0)21-68902737 Fax):+86(0)21-68392552 ---------- www.uts.com.cn ---------- Applicant : Nantong Fujitsu Microelectronic Co., Ltd Address : No.288, Chongchuan Road, Nantong, Jiangsu, China The following sample(s) was/were submitted and identified by/on behalf of the applicant as: Sample Name : SOP20 Receiving Date : Nov. 05, 2015 Testing Period : Nov. 05, 2015- Nov. 10, 2015 Test Requested : Please refer to next page(s). Test Method : Please refer to next page(s). Test Results : Please refer to next page(s).

Upload: haduong

Post on 20-Aug-2018

220 views

Category:

Documents


0 download

TRANSCRIPT

TEST REPORT

No. : SH151100059C09 Report Date: 2015/11/10

Approved by Salvia Hu Reviewed by Leo Liu Redact by Luciana WangPage 1 of 10

This Test Report is issued by the Company subject to its General Conditions of Service printed overleaf or available on request. Attention is drawn to the limitations of liability, indemnificationand jurisdictional policies defined therein. The results shown in this Test report refer only to the sample(s) tested unless otherwise stated This test report shall not be reproduced, except in full,without written approval of the Company. 本报告按本公司所制定之通用服务条款所编制发放。请注意本报告首页背面之此条款,本公司之义务、免责、管辖权均有明确规定,该条

款也可向本公司索取。除非另有说明,本报告仅对来样负责,未经许可,不得部分复制本报告。

优联(上海)检测有限公司 United (Shanghai) Testing ServicesCo.Ltd.地址:上海市外高桥保税区富特东三路76号32栋西3楼 200131 3/F., Building32,No.76 , Fute East 3 Road., Waigaoqiao Free Trade Zone, Shanghai, 200131电话(Tel):+86(0)21-68902737 (Fax):+86(0)21-68392552

---------- www.uts.com.cn ----------

Applicant : Nantong Fujitsu Microelectronic Co., LtdAddress : No.288, Chongchuan Road, Nantong, Jiangsu, China

The following sample(s) was/were submitted and identified by/on behalf of the applicant as:

Sample Name : SOP20

Receiving Date : Nov. 05, 2015

Testing Period : Nov. 05, 2015- Nov. 10, 2015

Test Requested : Please refer to next page(s).

Test Method : Please refer to next page(s).

Test Results : Please refer to next page(s).

TEST REPORT

No. : SH151100059C09 Report Date: 2015/11/10

Page 2 of 10---------- www.uts.com.cn ----------

TEST RESULTS:

Test Items Unit Methods MDLResults Limited

Value1# 2#

Pb mg/kgM1

2 N.D. N.D. 1000

Cd mg/kg 2 N.D. N.D. 100

Hg mg/kg M2 2 N.D. N.D. 1000

Cr (VI) mg/kg M3a/M3--- Negative --- ---(metal)

2 --- N.D. 1000(nonmetal)

Monobromobiphenyl (MonoBB) mg/kg

M4

5 --- N.D. ---Dibromobiphenyl (DiBB) mg/kg 5 --- N.D. ---Tribromobiphenyl (TriBB) mg/kg 5 --- N.D. ---Tetrabromobiphenyl (TetraBB) mg/kg 5 --- N.D. ---Pentabromobiphenyl (PentaBB) mg/kg 5 --- N.D. ---Hexabromobiphenyl (HexaBB) mg/kg 5 --- N.D. ---Heptabromobiphenyl (HeptaBB) mg/kg 5 --- N.D. ---Octabromobiphenyl (OctaBB) mg/kg 5 --- N.D. ---Nonabromobiphenyl (NonaBB) mg/kg 5 --- N.D. ---Decabromobiphenyl (DecaBB) mg/kg 5 --- N.D. ---Total PBBs / sum of above mg/kg --- --- N.D. 1000Monobromodiphenyl ether (MonoBDE) mg/kg 5 --- N.D. ---Dibromodiphenyl ether (DiBDE) mg/kg 5 --- N.D. ---Tribromodiphenyl ether (TriBDE) mg/kg 5 --- N.D. ---Tetrabromodiphenyl ether (TetraBDE) mg/kg 5 --- N.D. ---Pentabromodiphenyl ether (PentaBDE) mg/kg 5 --- N.D. ---Hexabromodiphenyl ether (HexaBDE) mg/kg 5 --- N.D. ---Heptabromodiphenyl ether (HeptaBDE) mg/kg 5 --- N.D. ---Octabromodiphenyl ether (OctaBDE) mg/kg 5 --- N.D. ---Nonabromodiphenyl ether (NonaBDE) mg/kg 5 --- N.D. ---Decabromodiphenyl ether (DecaBDE) mg/kg 5 --- N.D. ---Total PBDEs / sum of above mg/kg --- --- N.D. 1000

TEST REPORT

No. : SH151100059C09 Report Date: 2015/11/10

Page 3 of 10---------- www.uts.com.cn ----------

Test Items Unit Methods MDLResults Limited

Value1# 2#

Beryllium mg/kg

M5

2 N.D. N.D. ---

Beryllium oxide* mg/kg --- N.D. N.D. ---

Beryllium copper* mg/kg --- N.D. N.D. ---

Sb mg/kg 10 N.D. N.D. ---

Perfluorooctane Sulfonates (PFOS) mg/kgM6

0.001 N.D. N.D. 0.1

PFOA mg/kg 0.001 N.D. N.D. ---

HBCDD mg/kg M7 5 --- N.D. 1000

Diarsenic trioxide mg/kg

M5

50 --- N.D. ---

Diarsenic pentaoxide mg/kg 50 --- N.D. ---

Boric acid mg/kg 50 --- N.D. ---

Specific sodium borates mg/kg 50 --- N.D. ---

Polychlorinated biphenyls (PCB) mg/kg

M7

5 --- N.D. ---

Polychlorinated naphthalenes (PCN) mg/kg 5 --- N.D. ---

Polychlorinated terphenyls (PCT) mg/kg 5 --- N.D. ---

Other chlorinated organic compounds mg/kg M8 5 --- N.D. ---

Short-chain chlorinated paraffins (SCCP) mg/kgM7

5 --- N.D. 1000

Tris(2-chloroethyl) phosphate (TCEP) mg/kg 5 --- N.D. 1000

Other brominated organic compounds mg/kg

M8

5 --- N.D. ---

Hydrofluorocarbon (HFC) mg/kg 5 --- N.D. ---

Perfluorocarbon (PFC) mg/kg 5 --- N.D. ---

TEST REPORT

No. : SH151100059C09 Report Date: 2015/11/10

Page 4 of 10---------- www.uts.com.cn ----------

Test Items Unit Methods MDLResults Limited

Value2#Asbestos

Amosite %

M9

1 Negative ---

Chrysotile % 1 Negative ---

Crocidolite % 1 Negative ---

Anthophyllite % 1 Negative ---

Tremolite % 1 Negative ---

Actinolite % 1 Negative ---

Formaldehyde mg/L M10 0.02 N.D. ---

TBT mg/kg

M11

5 N.D. ---

TPT mg/kg 5 N.D. ---

DBT mg/kg 5 N.D. ---

DOT mg/kg 5 N.D. ---

Di-iso-nonyl phthalate (DINP) mg/kg

M7

50 N.D. ---

Di-n-octyl phthalate (DNOP) mg/kg 10 N.D. ---Di (2-ethyl hexyl)-phthalate (DEHP)(DOP)

mg/kg 10 N.D. ---

Diisodecyl phthalate (DIDP) mg/kg 50 N.D. ---

Butylbenzyl phthalate (BBP) mg/kg 10 N.D. ---

Diisobuty phthalate (DIBP) mg/kg 10 N.D. ---

Dibutuyl phthalate (DBP) mg/kg 10 N.D. ---

Di-n-hexyl phthalate (DNHP) mg/kg 10 N.D. ---

Dimethyl fumarate (DMF) mg/kg 0.1 N.D. ---

Specific benzotriazole mg/kg 5 N.D. ---1,2-Benzenedicarboxylic acid,di-C6-8-branched alkyl esters, C7-rich mg/kg 10 N.D. ---

1,2-Benzenedicarboxylic acid, ihexylester,branched and linear

mg/kg 10 N.D. ---

Bis(2-methoxyethyl) phthalate(DMEP) mg/kg 10 N.D. ---

Diisopentylphthalate (DIPP) mg/kg 10 N.D. ---

Dipentyl phthalate (DPP) mg/kg 10 N.D. ---

N-pentyl-isopentylphtalate mg/kg 10 N.D. ---

TEST REPORT

No. : SH151100059C09 Report Date: 2015/11/10

Page 5 of 10---------- www.uts.com.cn ----------

Test Items Unit Methods MDLResults Limited

Value2#Cobalt mg/kg

M52 N.D. ---

Cobalt dichloride** mg/kg --- N.D. ---

PolyvinylChloride (PVC)*** --- M12 --- Not detected ---

PVC Spectra

Asbestos Spectra

TEST REPORT

No. : SH151100059C09 Report Date: 2015/11/10

Page 6 of 10---------- www.uts.com.cn ----------

Test ItemsUnit Methods MDL

Results LimitedValueAmines Substances 2#

4-Aminobiphenyl mg/kg

M13

30 N.D. ---

Benzidine mg/kg 30 N.D. ---

4-Chloro-2-methylaniline mg/kg 30 N.D. ---

2-Aminonaphthalene mg/kg 30 N.D. ---

4-Amino-2’-3-dimethylazobenzene mg/kg 30 N.D. ---

5-nitro-o-toluidine mg/kg 30 N.D. ---

4-Chloroaniline mg/kg 30 N.D. ---

4-Methoxy-1, 3-phenylenediamine mg/kg 30 N.D. ---

Bis- (4-aminophenyl) methane mg/kg 30 N.D. ---

3,3'-Dichlorobenzidine mg/kg 30 N.D. ---

3,3'-Dimethoxybenzidine mg/kg 30 N.D. ---

3,3’-Dimethylbenzidine mg/kg 30 N.D. ---

4, 4’-Diamino-3, 3’-dimethyldiphenyl methane mg/kg 30 N.D. ---

2-Methoxy-5-methylaniline (Cresidine) mg/kg 30 N.D. ---

4,4'-Methylenebis(2-chloroaniline) mg/kg 30 N.D. ---

4,4’-Oxydianiline mg/kg 30 N.D. ---

4-Aminophenylthioether mg/kg 30 N.D. ---

o-Toluidine mg/kg 30 N.D. ---

2,4-Diaminotoluene mg/kg 30 N.D. ---

2,4,5-Trimethylaniline mg/kg 30 N.D. ---

2-Methoxyaniline mg/kg 30 N.D. ---

4-Aminoazobenzene mg/kg 30 N.D. ---

TEST REPORT

No. : SH151100059C09 Report Date: 2015/11/10

Page 7 of 10---------- www.uts.com.cn ----------

Test Items Unit Methods MDLResults Limited

Value2#

Methylene chloride (Dichloromethane) mg/kg

M8

1 N.D. ---

Carbon tetrachloride mg/kg 1 N.D. ---

Methyl chloroform=1,1,1-Trichloroethane mg/kg 1 N.D. ---

Halons

Halon-1211 mg/kg

M8

1 N.D. ---

Halon-1301 mg/kg 1 N.D. ---

Halon-2402 mg/kg 1 N.D. ---

CFC’s (Chlorofluorocarbons)

Group Ⅰ

Chlorofluorocarbon-11 mg/kg

M8

1 N.D. ---

Chlorofluorocarbon-12 mg/kg 1 N.D. ---

Chlorofluorocarbon-113 mg/kg 1 N.D. ---

Chlorofluorocarbon-114 mg/kg 1 N.D. ---

Chlorofluorocarbon-115 mg/kg 1 N.D. ---

Group Ⅱ

Chlorofluorocarbon-13 mg/kg

M8

1 N.D. ---

Chlorofluorocarbon-111 mg/kg 1 N.D. ---

Chlorofluorocarbon-112 mg/kg 1 N.D. ---

Chlorofluorocarbon-211 mg/kg 1 N.D. ---

Chlorofluorocarbon-212 mg/kg 1 N.D. ---

Chlorofluorocarbon-213 mg/kg 1 N.D. ---

Chlorofluorocarbon-214 mg/kg 1 N.D. ---

Chlorofluorocarbon-215 mg/kg 1 N.D. ---

Chlorofluorocarbon-216 mg/kg 1 N.D. ---

Chlorofluorocarbon-217 mg/kg 1 N.D. ---

TEST REPORT

No. : SH151100059C09 Report Date: 2015/11/10

Page 8 of 10---------- www.uts.com.cn ----------

Test Items Unit Methods MDLResults Limited

Value2#

HCFC’s (Hydrogenated chlorofluorocarbons)Hydrogenated chlorofluorocarbons-21 mg/kg

M8

1 N.D. ---Hydrogenated chlorofluorocarbons-22 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-31 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-121 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-122 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-123 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-124 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-131 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-131b mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-133a mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-141b mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-221 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-222 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-223 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-224 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-225ca mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-225cb mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-226 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-231 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-232 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-233 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-234 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-235 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-241 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-242 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-243 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-244 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-251 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-252 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-253 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-261 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-262 mg/kg 1 N.D. ---Hydrogenated chlorofluorocarbons-271 mg/kg 1 N.D. ---

TEST REPORT

No. : SH151100059C09 Report Date: 2015/11/10

Page 9 of 10---------- www.uts.com.cn ----------

Test Items Unit Methods MDLResults Limited

Value2#

Ethanol, dimethyl ether %

M5

0.01 N.D. ---

4 - (1,1,3,3 - methyl butyl) phenol % 0.01 N.D. ---

N, N - dimethyl acetamide(DMAC) % 0.01 N.D. ---

Ethylene glycol dimethyl ether(EGDME) % 0.01 N.D. ---

Perchlorate % 0.01 N.D. ---

Remark : 1) *Beryllium oxide and Beryllium copper test results are based on samples of Beryllium contentof a conversion.

2) ***The substance is calculated by using the test results of element (Cobalt) respectively (testinginstrument: ICP-OES)). If the sample contains total Cobalt, it needs further test the Chlorine(testing instrument: IC) content to make sure whether it includes Cobalt dichloride or not.

3) ***Infrared spectrogram of test sample and standard infrared spectrogram are included.

Note : 1) “---” = Not Regulated.2) MDL = Method Detection Limit.3) N.D. = Not detected, less than MDL.4) M1: With reference to IEC 62321-5: 2013, analysis was performed by ICP-OES.5) M2: With reference to IEC 62321-4: 2013, analysis was performed by ICP-OES.6) M3: With reference to IEC 62321: 2008, analysis was performed by UV-Vis.

M3a:With reference to IEC 62321-7-1: 2015, analysis was performed by UV-Vis ColorimetricDetermination.

7) M4: With reference to IEC 62321: 2008, analysis was performed by GC-MS.8) Spot test: Negative=Not detected Cr(VI) in plating; Positive=Detected Cr(VI) in plating.

(If you are not sure about the result of the Spot test, use the boiling water extraction methodto confirm the result)Boiling water extraction method:Negative:The Cr(VI) concentration of plating detected is blow 0.1μg/cm2;Positive:The Cr(VI) concentration of plating detected is above 0.13μg/cm2 ;Inconclusive:The Cr(VI) concentration of plating detected is between 0.1μg/cm2 and 0.13μg/cm2 .

9) M5: With reference to EPA 3052-1996 & EPA 6010C-2007, analysis was performed by ICP-OES.10) M6: With reference to EPA 3550C:2007 and EPA 8321B:2007 Detection of non-volatile material

that can be solvent extraction by high-performance liquid chromatography with thermal ionizationmass spectrometry.

11) M7: With reference to EPA 3550C-2007&EPA 8270D-2007, analysis was performed by GC-MS.12) M8: With reference to EPA 5021A, analysis was performed by HS-GC-MS.13) M9: With reference to NIOSH 9000 method, analysis was performed by XRD.

TEST REPORT

No. : SH151100059C09 Report Date: 2015/11/10

Page 10 of 10---------- www.uts.com.cn ----------

14) M10: With reference to JIS A 5905 analysis was performed by UV-VIS.15) M11: With reference to DIN EN ISO 17353:2005 , analysis was performed by GC-MS.16) M12: With reference to ASTM D2124-99 , analysis was performed by FTIR.17) M13: With reference to EN 14362-1: 2012, analysis was performed by GC-MS.18) Reference information: Directive (EU) No 757/201019) -(i) May not be placed on the market or used as a substance or constituent of preparations in a

concentration equal to or higher than 0.001% by mass.-(ii) May not be placed on the market in semi-finished products or articles, or parts thereof, if theconcentration of PFOS isequal to or higher than 0.1% by mass calculated with reference to the massof structurally or microstructurally distinct partsthat contain PFOS or, for textiles or other coatedmaterials, if the amount of PFOS is equal to or higher than 1μg/m2 of the coated material.- Specimens, which requested to determine Cadmium, Mercury, Lead, Beryllium, Cobalt Content,have been dissolved completely.

TEST PART DESCRIPTION: 1# Metallic pin 2# Black main body

SAMPLE PHOTO

…………… End of Report……………

1#2#