READ AND SAVE THESE INSTRUCTIONS Operator's Manual ® WHOLE HOUSE HUMIDIFIER 12 Gallon Output with Innovative Twin Fan Technology Model 758.144162 CAUTION: Before using this product, read this manual and follow all its Safety Rules and Operating Instructions. Safety Assembly Operation Maintenance Parts Espahol, p. 17 Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. www.sears.com Part No. SP6595 Printed in U.S.A.

Upload: others

Post on 02-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

READ AND SAVE THESE INSTRUCTIONSOperator's Manual

®

WHOLE HOUSE HUMIDIFIER12 Gallon Output withInnovative Twin Fan TechnologyModel 758.144162

CAUTION: Before using this

product, read this manual and

follow all its Safety Rules and

Operating Instructions.

• Safety• Assembly

• Operation• Maintenance

• Parts

• Espahol, p. 17

Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.www.sears.com

Part No. SP6595 Printed in U.S.A.

Page 2: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER

If any part of this humidifier fails due to a defect in material or workmanshipwithin one year from the date of purchase, or it the humidifier motor fails dueto a defect in material or workmanship during the second year from the dateof purchase, RETURN THE HUMIDIFIER TO THE NEAREST SEARS PARTS &REPAIR CENTER, and it will be repaired free of charge. This warranty doesnot include humidifier filters, which are expendable parts that can wear outfrom normal use in less than one year. This warranty gives you specific legalrights, and you may also have other rights which vary from state to state.

Sears Roebuck and Co. Dept. 817WA, Hoffman Estates IL 60179

GENERAL SAFETY INSTRUCTIONSSafety Signal WordsDANGER: means if the safetyinformation is not followed someone will

be seriously injured or killed.

WARNING: means if the safetyinformation is not followed someone

could be seriously injured or killed.

CAUTION: means if the safetyinformation is not followed someone maybe injured.

1. To reduce the risk of fire or shock

hazard, plug humidifier directly into a120V, A.C. electrical outlet. Do not useextension cords.

2. Keep the electric cord out of trafficareas. To reduce the risk of fire

hazard, never put the electric cordunder rugs, near heat registers,radiators, stoves or heaters.

3. Always unplug the humidifier beforemoving it, before cleaning, orwhenever the humidifier is not in

4. Keep the humidifier clean.5. Do not put foreign objects inside the

humidifier.

6. Do not allow to be used as a toy.Close attention is necessary whenused by or near children.

7. Never use your humidifier while anypart is missing or damaged in anymanner.

8. To reduce the risk of electrical

hazard or damage to humidifier, donot tilt, jolt or tip humidifier while unitis running.

9. To reduce the risk of damage tohumidifier, unplug when not in use.

10. To reduce the risk of accidental

electrical shock, do not touch thecord or controls with wet hands.

11. Note the warning label shown below.

WARNING: To reduce risk of fire,electric shock, or injury always unplugbefore servicing or cleaning.

service.

Table of ContentsWarranty Information ............................... 2General Safety Instructions .................... 2To Save A Service Call ........................... 3Know Your Humidifier ............................. 3How Your Humidifier Works .................... 4

Assembly ................................................ 4Location Instructions .............................. 5

Electrical Hook-Up .................................. 5

Water Fill ................................................. 6

Operating Humidifier Controls ............... 7Using Your Humidifier ............................. 8Operating Tips for Best Performance .....8Replacement and Care of Filters ....... 9-10Cleaning and Maintenance .............. 11-12Troubleshooting ................................... 13Repair Parts ..................................... 14-15

Page 3: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

To Save A Service CallCheck the following if your humidifier isnot operating.1. Is power cord attached to outlet?

2. Is there electrical power to outlet?

Know Your Humidifier

Controls_

3. Is airflow control in operating position?

4. Is humidity control set high enough?

5. Is there enough water in the humidifiercabinet?

j Fan Assembly

Splash Guard

FilterHousing...

Filters:ReplacementFilter 32-14912

Pivoting Lid

Pivoting Lid Removed For Clarity

Description

Gallon Output/24 hrs

Capacity of Bottles

Sq. Ft. Coverage

Fan SpeedsFilters

758.144162

12

4.75 Gallons

2500

3

4 Pack(32-14912)Water Level Indicator

Fill Indicator

Auto Shut Off

Auto Humidistat

Controls

ETL Listed

Volts

Hertz

AmpsWatts

Yes

Yes

Yes

Yes

RotaryYes

120 A.C.

6O

2.28

130

Based on an area with average insulation and an 8 footceiling height.

Page 4: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

How Your Humidifier WorksYour new Kenmore humidifier is designedto satisfy home humidity requirementsthrough the principle of evaporation ofwater in the air.

After water is added to the bottle, the

filters begin to soak up the water andbecome totally saturated in approxi-mately 30 minutes. Air is drawn in fromthe rear of the humidifier and through the

filters by means of circulation fans. As airpasses through the filters, moisture isabsorbed into the air and then released

in the form of vapor. No water dropletswilt enter the home. All evaporation intothe air takes place in the humidifier,

which means that the residue left byevaporating water is not passed into thehome, but remains in the filter.

CAUTION: Use only 32-14900 EPARegistered Bacteriostat availablefrom Sears Retail store. Under no

circumstances should you use watertreatment products designed forRoto belt or Ultrasonic humidifiers.

Humidified Air is ThenReleased Through the Top

Dry Air _i!EntersThroughthe Rear '

i II

I

CAUTION: Keep your humidifierclean. While humidifiers do not causecolds, some studies suggest that dirtyhumidifier can cause cold-likesymptoms in some people. To reducethe risk of this, we recommend youclean your humidifier weekly withHumidifier Cleaner 32-14713 and useBacteriostat 32-14900. These areavailable at your local Sears store.

AssemblyYour new Sears Kenmore humidifier is

completely assembled for you to use.Remove the packaging material frominside your humidifier and follow theinstructions of this operatorlt manual forproper usage. The packaging material islocated under the fan assembly. Removethe packaging material and discard.

NOTE: The filters may have shiftedduring shipping. Ensure that they areproperly seated in the bottom of thecabinet below the top filter housingsbefore filling. Refer to "Replacement andCare of Filters" section on page 9.

Page 5: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

Location Instructions

WARNING: For your own safety, do Inot use humidifier if any parts are Idamaged or missing.

Step 1:Place humidifier on a fiat level surface inan area of your house where humidity isneeded most, or in an area which wouldlikely result in moist air being circulatedthroughout the house, such as near acold air return.

Placing the unit level is very important ifthe humidifier is located on carpeting.

Moist air (humidity) produced wiltdisperse into the whole house, but areaclosest to the unit wilt have the highesthumidity. If the unit is positioned close toa window, condensation may form on thewindow pane. If this is not appropriatethe unit should be repositioned in anotherlocation.

NOTE: Due to release of cool, moist airfrom humidifier, it is best to direct airaway from home thermostat and hot airregisters. It is best to position humidifiernext to an inside wall. Hot air registersand cold air from outside walls can affectthe efficiencies of the controls. Unitshould not be placed where warm airfrom a hot air register blows directly onunit.

Step 2:

The humidifier should be positioned withthe back (cord exit side), at least 2inches away from the walt. Air needs toenter through the louvers in the rearpanel in order for the humidifier tooperate at peak efficiency.

At Least 2" From Wall

Electrical Hook-UpLocate nearest 120V A.C. walt socket in

the location desired, preferably on insidewalt. With the humidifier in the desired

location, route the electrical cord safelyso no one will trip or upset the humidifier.Plug in the electrical cord.

WARNING: To reduce the risk of fireor shock hazard, humidifier shouldbe plugged into a 120VA.C. outlet.Do not use extension cords.

To reduce the risk of electrical shock, this

humidifier has a polarized plug (oneblade is wider than the other). This plugwill fit in a polarized outlet only one way.

If the plug does not fit fully in the outlet,reverse plug. If it still does not fit, contacta qualified electrician to install the properoutlet. Do not change the plug in any way.

Page 6: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

Water Fill

WARNING: To reduce the risk ofshock, always unplug humidifierbefore cleaning or servicing.

WARNING: To reduce the risk of fireor shock hazard, do not pour or spillwater into control or motor area.

If controls get wet, let them drycompletely and have unit checked byauthorized service personnel beforeplugging in.

This humidifier is designed to be filledusing a bucket fill method. The unitshould be positioned where it will beoperating. To fill the humidifier, close thecontrol cover and open the pivoting lid.Notice the splash guard inside thecabinet of the humidifier.

Use recommended mixture of cold water

and if necessary Sears Bacteriostat #32-14900 only. Pour the water slowly from abucket into the cabinet onto the center ofsplash guard.

NOTE: Deflect water off center of splashguard when filling. The water deflects offthe splash guard and drops into thebottom of the cabinet. Do not pour wateronto top of unit or control area.

Standing in front of the humidifier, noticethe "FULL" labels positioned to the leftand right at the bottom inside of thecabinet. These labels indicate themaximum amount of water that can bepoured into the humidifier.

Do not fill water in the cabinet abovethis line. If you do, water will leak outof the cabinet and onto the floor.

Pivoting Lid

Cabinet_

Front of Humidifier

Page 7: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

Operating Humidifier ControlsThe operating controls of your KenmoreQuiet Comfort whole house humidifier are

located on the top center of thehumidifier. The controls are found under

the smoked control cover, located

between the air circulating fans.

Fill Indicator:

When the unit has a small amount of

water left in it, the small window next toFill on the control panel wilt appearorange and the unit will automaticallyshut off.

Lift the control cover by placing yourfinger in the round cutout and lifting. Thecover will stay open. Now you can clearlysee the controls area. Familiarize yourselfwith the controls and reference the

diagram of the control area for the correctnaming used in this manual.

To Operate the Controls

Humidity Control: OAdjust the amount of humidity dependingon your needs. The humidifier wilt turn onthe off as required to maintain level ofhumidity selected. A medium setting isrecommended, but there are times whenlow or high amount of humidity may bepreferred. For constant operation ofhumidifier, rotate humidity knob all theway clockwise. This allows for themaximum amount of humidity to beevaporated into the air continuously.

IMPORTANT: Water damage may resultif condensation starts to form on windows

or walls. Humidity Control setting shouldbe lowered until condensation no longerforms.

Speed Control: OYour Kenmore humidifier has a three

speed rotary fan control. The higher theair flow speed, the more water isevaporated and released into the air.Low speed "." is the quietest and isprovided for conditions that may notrequire as high an evaporation rate.

Water Level Indicator:

This humidifier is equipped with a waterlevel gauge located in the center of thecontrol panel. When the cabinet is full ofwater the large window opposite thescale wilt show green. As water isdepleted the amount of green willdecrease to correspond with the scale.

NOTE: The cabinet may have a smallamount of water in it once unit shuts off.

Indicator

Manual Dryout:

At the end of the humidification season or

if you do not plan to run the humidifier forone week or more, you can override theautomatic shutoff function to completelydry the humidifier cabinet out.

To do this, simply slide the float retainerlocated at the back of the humidifier

cabinet to the top position of the slot it islocated in. This wilt hold the float in an

upward position and the fans will run untilyou turn the power off.

NOTE: Be sure to position float retainerto the normal operating mode (lowestposition in slot) for humidifier operation.

The following diagram is of the slot thefloat retainer is located in at the back ofthe cabinet.

Top PositionBack of Cabinet is for Manual

_ Dryout

Bottom Positionis for Normal

Operation Mode

Link ArmAssemblyRetainer Slot

Page 8: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

Using Your HumidifierStep 1:Be sure humidifier is full of water and

plugged in.

Step 2:Set Speed Control " I_ " to lowestspeed ".".

Step 3:

Set Humidity Control " _ " to mediumposition.

NOTE: Humidifier should operate withhumidity control on the recommendedmedium setting. If it does not, thehumidity is at a relatively high level.

To test the unit under this condition, turnHumidity Control all the way to clockwiseand unit should begin to operate. Afterthe unit has been tested, set HumidityControl to medium or desired level.

Allow 24 hours for humidifier to adjust.

If humidity level in home is sufficient, thehumidifier will only operate with HumidityControl turned all the way clockwise.

IMPORTANT: Water damage may resultif condensation starts to form on windows

or walls. Humidity Control setting shouldbe lowered until condensation no longerforms.

Step 4:If humidifier stops running and the unit isnot empty, the humidity level is at thenormal requirements for that setting or it

is adjusting to the home conditions. Thetable below shows recommended indoor

humidity levels. The figure showsapproximate relative humiditypercentages which correspond to thevarious settings of the Humidity Control.

When Outdoor

Temperature is:

-10°F0°F10°F20°F

Recommended Indoor

Relative Humidity is:

20%25%30%35%

ReZ,!,

'-)_a

Operating Tips for Best Performance1. Position the humidifier at least 2 inches

from any wall and away from any heatregisters.

2. Do not restrict airflow from entering orexiting the humidifier.

3. Use Sears recommended bacteriostat

32-14900 to retard bacteria growththat may cause odors and may beharmful to your health.

4. Perform regular cleaning as instructedin "Cleaning and Maintenance" sectionof this manual.

5. Replace the evaporative wicking filtersat least once per humidificationseason or more depending on waterconditions in your area.

Page 9: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

Replacement and Care of FiltersWARNING: To reduce the risk ofshock or injury from moving parts,always unplug humidifier beforeremoving or replacing any parts.

\ Lid

Fan Assembly/

/

CAUTION: To help retard bacteriagrowth and keep maximum efficiency,the filter should be replaced at leastonce per season, or more oftenunder hard water conditions. UseKenmore 32-14912 recommendedreplacement filter.

All filters may be rinsed periodically inclear water only. Take care not to damagepaper. To replace evaporative wickingfilters in your Kenmore Quiet ComfortWhole House humidifier, follow theseinstructions.

1. Unplug humidifier and proceed toclean. Before removing the filters, werecommend moving the humidifier toan area where floor coverings are notsusceptible to water damage, i.e.kitchen or bath areas.

2. To remove parts: Remove the fanassembly by opening the pivoting lid.Grasp the fan assembly front centerand rear center. Lift off and set asideon a clean flat surface. The filterhousings are now accessible.

NOTE: There are two filter housingassemblies. Each assembly consists ofa top filter housing and a front filterhousing. The front filter housing containstabs that secure the top filter housing.Do not remove the front filter housings.

3. To remove top filter housing, deflectthe two vertical tabs on top of frontfilter housing and lift up and out ofcabinet. With a soft, absorbent clothremove any remaining water or loosemineral deposits not trapped in thefilter from the filter housingassemblies.

4. Remove the two filters and dispose ofproperly. Repeat for other top filterhousing. Clean internal parts ofhumidifier per the'Cleaning andMaintenance" section of this operatorl_manual.

Humidifier

//

Top Filter Link ArmHousings Assembly

,......................Retainer/

Tab on FrontFilter Housing

FloatAssembly

Front of Humidifier(Top View)

Link ArmAssembhRetainer

Float Pivot/ Arm

/Float

Exploded View of Float Assembly

Page 10: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

Replacement and Care of Filters (cont'd.)

5. a. Install new filter (32-14912)in thebottom of the cabinet.

NOTE: The new filters wilt only fit into thecabinet one way. Take note of the innercabinet detail where the filters sit. Eachpair of filters must be positioned so theglue beads face out from each other.Refer to Figure 5a.

b. Place the filters into the bottom ofthe cabinet so the open pleats slipover the tabs in the bottom of thecabinet. Repeat for other side.

c. Reposition top filter housings on topof filters and snap into front filterhousings.

d. Position fan assembly onto thecabinet. Make sure the fan venturi

(lowest cylinder section below thefan) is placed inside the top filterhousings.

e. Close the pivoting lid on the fanassembly.

f. The unit is ready for use or to bestored away for next season.

Front Filter HousingFront of Humidifier

Figure 5a - Filter Locations Marked X

Top Filter Link ArmHousings Assembly......................Retainer

/

Tab on FrontFilter Housing

FloatAssembly

Front of Humidifier(Top View)

10

Page 11: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

Cleaning and MaintenanceWARNING: To reduce the risk of injury,fire or damage to humidifier, use onlycleaners specifically recommended forhumidifiers. Never use flammable,combustible or poisonous materials toclean your humidifier. To reduce therisk of scalds and damage tohumidifier, never put hot water inhumidifier.

CAUTION: Local water purity variesfrom area to area and under certainconditions water impurities andairborne bacteria may promote thegrowth of microorganisms in thereservoir of the humidifier.

To retard bacteria growth that maycause odors and be harmful to yourhealth, use only Sears replacementfilters. We also recommend using EPAapproved bacteriostat, 32-14900 andhumidifier cleaner, 32-14713, availableat your local Sears store.

NOTE: If it is necessary to use approvedbacteriostat, follow directions correctly.The cabinet of the whole house

humidifier will hold 4-3/4 gallons of water.

Step 1:

To make cleaning easier, the humidifiercabinet should be empty and completelydried out. To accomplish this, use thefollowing method:a. On the back side of the humidifier

cabinet, find the float retainer. In

normal operating mode, the retainerwilt be positioned in the bottom of theslot in the cabinet. Push the retainer

up to the top slot position in thecabinet until it locks in place. (See"Manual Dryout" section on page 8.)

b. Allow the humidifier to run until there isno water left in the cabinet.

c. Unplug humidifier.

WARNING: To reduce the risk of shock,always unplug humidifier beforecleaning or servicing. If humidifier is notunplugged, fan could start afterhousing is removed.

Step 2:To Remove Partsa. Remove the fan assembly by opening

the pivoting lid. Grasp the fanassembly front center and rear center.Lift off and set aside on a clean flatsurface.

b. Before removing the internal parts ofthe humidifier cabinet, we recommendmoving the humidifier to an areawhere floor covers are not susceptibleto water damage, i.e.; kitchen or batharea.

c. Deflect the two vertical tabs on top ofthe front filter housing to release thetop filter housing. Lift top filter housingstraight up and out of cabinet. Repeatfor other top filter housing.

d. Remove old filters and dispose ofproperly.

e. Remove the water level float from thehumidifier cabinet by pinching the floatretainer to release it from the cabinet.The cabinet should be empty beforecleaning. The cabinet consists of thelower areas of the humidifier wherethe filters are during normal operationtime.

f. Empty cabinet of any remaining water.g. Proceed to "Bi-Weekly Maintenance"

or "End of Season Maintenance" andthen continue as described below.

Step 3:Install new filters (Kenmore 32-14912Replacement Filters) into the locationwhere the old filters were positioned.Reinstall the water level float assemblyinto the cabinet.

NOTE: Link arm assembly retainershould be positioned in normal operatingmode. Assure that it is positioned in thebottom of the slot in the back of thecabinet (See page 7 for diagram of slot).Reposition top filter housing on top of thefilters and snap onto front filter housings.Position the fan assembly on top of thecabinet and return the humidifier to thedesired location for use.Refill humidifier cabinet with fresh coolwater. Plug the unit into a 120 vott A.C.power outlet and set the controls per the"Operating Humidifier Controls" section ofthis manual.

11

Page 12: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

Cleaning and Maintenance (cont'd.)Bi-Weekly Maintenance End of Season Maintenance

Removing Scale1. Fill the humidifier base with one 8

oz. cup of undiluted white vinegar.Let solution stay 20 minutes.

2. Clean all interior surfaces with asoft brush. Dampen a soft clothwith undiluted white vinegar andwipe out the base to remove scale.

3. Rinse thoroughly with clean warmwater to remove scale and cleaningsolution before disinfecting cabinet.

4. Dust the fan assembly and outsidesurfaces with a soft cloth only.

1. Foltow"Bi-Weekly Maintenance"instructions at end of humidificationseason.

2. Remove and throw away filters.

3. Let humidifier dry completely beforestoring. Do not store with water insidecabinet.

4. Store in coot, dry location.

5. Install a new filters in clean humidifier

before next season begins.

6. "Bi-Weekly Maintenance" procedure isalso recommended if you do not planto run the humidifier for one week or

Disinfecting HumidifierCabinet

more.

1. Fill humidifier cabinet with 1

teaspoon chlorine bleach in 1gallon of water. Let solution stay for20 minutes, carefully swishingevery few minutes. Wet all surfacesnormally exposed to water.

2. Empty humidifier cabinet after 20minutes. Rinse with water untilbleach smell is gone. Allow unit todry out completely..

12

Page 13: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

Troubleshooting

Trouble Probable Cause Remedy

Unit will not run. • Selected humidity level has • Raise humidistat setting ifbeen established, desired.

• No Power. • Check 120 volt source for

power.

Unit will not shut off.

Unit will not dry out completely.

• Float retainer is positioned in •"Manual Dryout" position.

• Float is not free.

• A small amount of waterremains in cabinet whenwater level indicator readsFILL.

Slide link arm assemblyretainer to lowest position inslot at back of cabinet. (Seepage 7).Free float from obstruction.

Position float assembly in"Manual Dryout" position.(See page 7).

Unit is not emptying during • Dirty filters. • Change to fresh new filters.use.

Water runts out of rear of unit. • Water splashing during filling. •

Water level gauge notfunctioning properly.

• Filters interfering with float. •

Deflect fill water off the center

of the splash guard.Do not overfill past "Full" labelin cabinet.

Be sure filters are positionedproperly in bottom of cabinet.(See page 9).

CAUTION: Use only 32-14900 EPA Registered Bacteriostat available from Sears Retail store.Use of other water treatment products may damage the filter elements.Under no circumstances should you use water treatment products designed for Roto belt orUltrasonic humidifiers.

13

Page 14: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

Repair PartsParts List for Kenmore Humidifier

Model No. 144162

J2

I_ _

i

j4

7

14

Page 15: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

Repair PartsParts List for Kenmore Humidifier

Model No. 144162Always order by part number - Not by key number

KeyNo Part No. Description

1 828741-2 Lid,Stationary

2 828742-0 Lid, Pivoting

3 832308-0 Control Assembly4 828199-8 Cabinet

5 823726 Rail, Kick

6 STD601107 * Screw, Pan Hd. Ty "AB" #10 x 3/4

7 828515 Caster, Twin Wheel

8 828195-0 Support, Filter Front

9 32-14912 t Filter,Evaporative

10 828534-0 Support, Motor

11 828115-0 Motor

12 822406-1 Fan

13 828194-0 Support, Upper Filter

14 824101-0 Retainer,Float

15 828200-3 Float,Water Level

-- SP6595 Operator's Manual (not illustrated)

NOTE: Any attempt to repair the control assembly or motormay create a hazard unless repair is done by a qualifiedservice technician. Repair service is available at your nearestSears store.

* Standard Hardware Item - May be purchased locally

1- Stock item - May be secured through the HardwareDepartment of most Sears retail stores.

15

Page 16: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

Notes

16

Page 17: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

LEAY GUARDEESTASINSTRUCCIONESManualdelusuario

®

HUMIDIFICADORPARATODALACASAProducci6nde 12 galonescontecnologiainnovadorade ventiladoresgemelosmodelo758.144162

PRECAUCION:Antesdeutilizareste

producto,lea estemanualy sigatodaslasnormasde seguridadeinstruccionesdeutilizaci6n.

• Seguridad

• Ensamblaje• Utilizaci6n• Mantenimiento• Piezas

Sears,RoebuckandCo.,HoffmanEstates,IL60179 U.S.A.www.sears.com

No. de piezaSP6595 Impreso en U.S.A.

Page 18: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

GARANTJACOIVlPLETADE UNA_IOPARAEL HUIVlIDIFICADORKENIVlORE

Sicualquierpiezadeestehumidificadorfalladebidoa nndefectodematerialodefabricaci6ndentrodelplazodeunafioa partirdelafechadecompra,osiel motordelhumidificadorfalladebidoa undefectode materialo de fabricaci6nduranteel segundoafioa partirde la fechade compra,DEVUELVAELHUMIDIFICADORALCENTRODEPIEZASYREPARACIONDESEARSMASCERCANOy ser_reparadosin ning_ncargo.Estagarantiano incluyelosfiltrosdelhumidificador,quesonpiezasperecederasquesepuedendesgastarpor causadelusonormalenmenosdeun afio.Estagarantialeconfiereaustedderechoslegalesespecificosy esposiblequeustedtambi6ntengaotrosderechosquevariandeunestadoa otro.

Sears RoebuckandCo. Dept.817WA,HoffmanEstatesIL60179

INSTRUCCIONESGENERALESDESEGURIDADPalabrasdeserialdeseguridadPELIGRO: Significa que si no se sigue lainformaci6n de seguridad, alguien resultar_lesionadogravementeo morir&

ADVERTENCIA:Significa que si no se sigue lainformaci6n de seguridad,alguien podriaresultarlesionadogravementeo morir.

PRECAUCION:Significa que si no se sigue lainformaci6n de seguridad, alguien pudieraresultar lesionado.

1. Parareducir el riesgo depeligrode incendioodescargas el_ctricas, enchufe el humidi-ficador directamenteen un tomacorriente de120 V C.A. No usecordonesde extensi6n.

2. Mantenga el cable el6ctrico alejado de laszonas de tr_.fico. Para reducir el riesgo depeligro de incendio, no ponga nunca elcord6n el_ctrico debajodealfombras ni cercade salidas de calor, radiadores de calor,estufas de cocinao calentadores.

3. Desenchufe siempre el humidificador antesde trasladarlo, antes de limpiarlo o siempreque noest6 enservicio.

4. Mantengalimpio el humidificador.

5. No ponga objetos extra_os dentro delhumidificador.

6. Nodeje queel humidificador se use como unjuguete. Es necesarioprestar muchaatenci6ncuando el humidificador seausado por ni_oso cerca deellos.

7. No utilice nunca el humidificador mientrasalguna piezafalte o est6da_ada de cualquiermanera.

8. Para reducir el riesgo de peligro el6ctrico oda_os al humidificador, no incline, sacuda nivuelque el humidificador mientras la unidadest_ en marcha.

9. Para reducir el riesgo de da_os al humi-dificador, desenchQfelo cuando no est6 enUSO.

10. Parareducir el riesgo de descargasel6ctricasaccidentales, no toque el cable de alimenta-ci6n ni los controles con las manos mojadas.

11. Fijese en la etiqueta de advertencia que semuestraa continuaci6n.

ADVERTENCIA:Parareducirel riesgodeincendio,descargas el6ctricas o lesiones, desenchufesiempreel humidificadorantesdehacerleserviciodeajustesy reparacioneso limpiarlo.

Informaci6ndegarantia...............................18Instruccionesgeneralesdeseguridad.........18ParaahorrarseunaIlamadadeservicio.......19Familiaricesecon elhumidificador..............1906mofuncionael humidificador.................20Ensamblaje......................................................4Instruccionesde ubicaci6n..........................21Conexi6nel_ctrica......................................21Llenadocon agua ........................................22

Utilizaci6n de los controlesdel humidificador .....................................23

Utilizaci6n del humidificador .........................24

Consejos de utilizaci6n para Iograrel mejor rendimiento .................................24

Reemplazoy cuidado de los filtros ........25-26Limpieza y mantenimiento ......................27-28Resoluci6n de problemas ............................29Piezasde repuesto .................................30-31

18

Page 19: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

ParaahorrarseunaIlamadadeservicioCompruebe Io siguiente si el humidificador nofunciona.1. 6Est,. el cable de alimentaci6n conectado a

un tomacorriente?

2. 6Hay alimentaci6n el6ctrica altomacorriente?

3. 6Est,. el control del flujo de aire en laposici6n de funcionamiento?

4. 6Est,. el control de humedad ajustado a unnivel Io suficientemente alto?

5. 6Hay suficiente agua en el gabinete delhumidificador?

Familiariceseconel humidificador

Controles.Conjuntodelventilador

f Protectorcontrasalpicaduras

Carcasadelfiltro

Filtro:No.derepuesto32-14912 Tapapivotante

Sehaquitadolatapapivotanteparamayorclaridad

Descripci6n

Producci6n en galones/24 h

Capacidadde las botellasCobertura en pies cuadradosVelocidades del ventiladorFiltros

758.144162

12

4,75 galones2500

3

Paquete de4 (32-14912)Indicador del nivel de aguaIndicador de Ilenado

Apagadoautom_.tico

Higrostato autom_.ticoOontroles

Catalogadopor ETL

VoltajeFrecuencia

Intensidad (alta velocidad)

Potencia (alta velocidad)

SiSiSiSi

GiratoriosSi

120V C.A.60 Hz2,28A130W

Basada en una zona con aislamiento promedio y una altura dehabitaciOnde 2,44 m (8 pies).

19

Page 20: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

C6mofuncionae/humidificadorSu nuevo humidificador Kenmoreest,. dise_ado

para satisfacer los requisitos de humedad delhogar a trav_s del principio de laevaporaci6ndel

agua enel aire.

Despu_s de a_adir agua a la botella, los filtroscomienzan a absorber el agua y se saturantotalmente enaproximadamente30 minutos. Se

hace entrar aire de la parte trasera del humidi-ficador y a trav_s de los filtros por medio de losventiladoresdecirculaci6n. A medidaque el airepasaa trav_s de losfiltros, absorbehumedad,lacual se libera a continuaci6nen forma de vapor.No entrar_.ngotitas de agua en la casa. Todala

evaporaci6n al aire tiene lugar en el humidi-ficador, Io cual significaque los residuosdejadospor elagua quese evaporano se pasana lacasa,sino que permanecenen elfiltro.

PRECAUCION:Utilice _nicamenteunbacterios-

tato registrado por EPA 32-14900, el cualse puede obtener en una tienda minoristaSears. En ninguna circunstancia debe ustedusar productos de tratamiento de aguadise_ados para humidificadoresde rotocorreao ultras6nicos.

Luego,seexpulsaairehumidificadoatrav6sdela partesuperior

Elaireseco .."//.."_r;t:..;;_"entraa trav6s .; :: ."delaparte "'"';' "_"_trasera

i

I

PRECAUCION:Mantenga limpio el humidifi-cador.Aunque los humidificadores no causanresfriados, algunos estudios sugieren que unhumidificador sucio puede causar sintomas_arecidosa los de los resfriados en algunas_ersonas.Para reducir este riesgo, recomen-damos que limpie el humidificador semanal-mente con el limpiador de humidificador32-14713 y utilize el bacteriostato 32-14900.Estos se pueden conseguir en la tiendaminorista Searsm_.scercana.

EnsamblajeSu nuevo humidificador Sears Kenmore viene

completamenteensambladolisto paraque ustedIo use. Saque el material de empaquetamiento

del interior del humidificador y siga lasinstrucciones contenidas en este manual del

usuario para utilizar correctamente elhumidificador. El material de empaquetamientoest,. ubicado debajo del conjunto de losventiladores. Saque el material de

empaquetamientoy des@helo.

NOTA: Los filtros pueden haber cambiado deposicidn duranteeltransporte. Aseg_resedequeest_n asentadoscorrectamente en el fondo del

gabinete, debajo de las carcasassuperiores delos filtros, antes de Ilenar la unidad. Consulte la

secci6n "Reemplazoy cuidado de los filtros" enla p_.gina25.

2O

Page 21: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

Instruccionesdeubicaci6n

ADVERTENCIA:Para su propia seguridad, no

utilice el humidificador si alguna pieza est,.da_adao falta.

Paso1:

Coloqueel humidificador enuna superficie planay nivelada,en un _.reade su casadonde m_.ssenecesite la humedad o en un _.reaen la queprobablementese har_.circular aire hQmedoportoda la casa, como por ejemplo cerca de unretorno de airefrio.

La colocaci6n de la unidad de modo que est_nivelada es muy importante si el humidificadorest,. ubicadosobre unaalfombra.

El aire hQmedo(la humedad)que se producesedispersar_,por toda la casa, pero el _.ream_.spr6xima a la unidadtendr_,la humedadm_.salta.Si la unidad est,. posicionadacerca de unaven-tana,es posibleque seforme condensaci6nenelvidrio de la ventana.Si esto no es apropiado, sedebe reposicionar la unidaden otra ubicaci6n.

NOTA:Debidoa que el humidificadorexpulsaairefrio y hQmedo, Io mejor es dirigir el aire alej_.n-dolo del termostato de la casay las salidas deaire caliente. Lo mejor es posicionar el humidifi-

cador junto a una pared interior. Las salidas deaire caliente y el aire frio procedente de lasparedesexteriorespuedenafectar las eficienciasde los controles. Launidadno sedebe colocar en

lugares donde el aire templado de una salida deaire calientesople directamentehaciaella.

Paso2:

El humidificador se debe posicionar con la partetrasera (el lado de salida del cable de alimenta-ci6n) al menos a 2 pulgadas (5 cm) de la pared.Es necesarioque entreaire a trav_s de las rejillasubicadas en el panel trasero para que elhumidificador funcione con la m_ima eficiencia.

AI menosa 5 cm (2 pulg.) de la pared

Conexi6ne/ ctricaLocaliceel tomacorrientede paredde 120 V C.A.m_.scercanoen la ubicaci6n deseada,preferible-mente en una pared interior. Con el humi-dificador en la ubicaci6n deseada, dirija elcord6n el@trico demodo seguro paraque nadietropiece con _1 ni desajuste el humidificador.Enchufeel cord6n el@trico.

Si el enchufe no entra completamente en eltomacorriente, invierta el enchufe. Si sigue sinentrar, p6ngase en contacto con un electricistacalificado paraqueinstaleel tomacorrienteapro-piado. Nocambie el enchufe de ningQnmodo.

ADVERTENCIA:Para reducir el riesgo depeligro de incendio o descargasel@tricas, elhumidificador debe enchufarse en un toma-corrientede 120 V C.A. No utilice cordonesdeextensi6n.

Para reducir el riesgo de descargas el@tricas,este humidificador tiene un enchufe polarizado(un terminal es m_.sancho que el otro). Esteenchufe entrar_,de un solo modo en un toma-

corriente polarizado.

21

Page 22: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

LlenadoconaguaADVERTENCIA:Para reducir el riesgo dedescargas el_ctricas, desenchufe siempre elhumidificador antes de limpiarlo o hacerleserviciode ajustesy reparaciones.

ADVERTENCIA:Para reducir el riesgo depeligro de incendio o descargasel_ctricas, noeche ni derrame agua en el _.rea de loscontroles o del motor. Si los controles se

mojan, deje que se sequen completamente yhaga que la unidad sea revisadapor personaldeservicio autorizadoantes deenchufarla.

Este humidificador est,. dise_ado para Ilenarseutilizando un m_todo de Ilenado con cubo. La

unidad se debe posicionar en el lugar donde sevayaa utilizar.ParaIlenarel humidificador, pongala cubierta de los controles enposici6n cerradayponga latapa pivotanteenposici6nabierta. Fijeseen el protector contra salpicadurasubicadoen elinterior del gabinetedel humidificador.

Use la mezcla recomendadadeagua fria y, si esnecesario, bacteriostato Sears No. 32-14900solamente. Eche el agua lentamente en elgabinete con un cubo, sobre el centro delprotector contra salpicaduras.

NOTA:Echeel agua demodo que se desvie enelcentro del protector contra salpicadurascuando

Ilene la unidad. Elagua se desviaen el protectorcontra salpicadurasy caeal fondo del gabinete.No echeagua en la partesuperior de la unidad nien el_.reade los controles.

SitQesedelante del humidificador y fijese en las

etiquetas de "FULL" (LLENO) ubicadas a laizquierday a la derechadel fondo enel interior delgabinete. Estas etiquetas indican la cantidadm_ima de agua que se puede echar en elhumidificador.

No Ileneel gabineteconaguaporencimadeestalinea.Si Iohace,el aguaseescapar_delgabinetey caer_al piso.

Tapa pivotante

Gabinete

Parle delanteradel humidificador

22

Page 23: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

Uti/izaci6nde loscontrolesde/humidificadorLos controles de utilizaci6n del humidificador

para toda la casa KenmoreQuiet Comfort est_.nubicados en la parte superior central del humi-dificador. Los controles se encuentrandebajo dela cubierta ahumada de los controles, ubicadaentre los ventiladoresdecirculacidn deaire.

Levantelacubierta de los controles colocandoun

dedo en laabertura redonday tirando con _1haciaarriba. La cubierta permanecer_,en posici6nabierta.Unavezhecho esto,podr_,verclaramenteel _.reade los controles. Familiaricesecon los

controles y consulte el diagramadel _.reade loscontroles para obtener los nombres correctosque se utilizanen estemanual.

Indicadorde Ilenado:

Cuandoa la unidad le quede una peque5acan-tidad deagua en su interior, la ventana peque5aque est,. junto al indicador de Ilenadoenel panelde controles se pondr_,naranja y la unidad se

apagar_,autom_.ticamente.

NOTA:Elgabinete puedetener una peque5acan-

tidad de agua unavez que la unidadse apague.

Parautilizarlos controlesControldehumedad:_)

Ajuste la cantidadde humedadseg_n sus nece-sidades.El humidificador se encender_,y apagar_.segQn se requiera para mantener el nivel dehumedadseleccionado.Se recomiendaunajusteintermedio, pero hayocasionesen que se puedepreferir una cantidad de humedad baja o alta.Para que el humidificador funcione constante-mente, gire el bot6n giratorio de humedadcompletamente en el sentido de las agujas delreloj. Estopermite quese evaporecontinuamenteal aire la m_ima cantidad dehumedad.

IMPORTANTE:Se pueden producir da_os causa-dos por agua si se empiezaa formar condensa-ci6n en las ventanas o en las paredes. Elajustedel control de humedad debe bajarsehasta queya no se forme condensaci6n.

Controldevelocidad:

Este humidificador Kenmoretiene un control deventilador giratorio de tres velocidades. Cuantom_.salta sea la velocidad del flujo de aire, m_.sagua se evaporar_,y se liberar_, al aire. Lavelocidad baja "o" es la m_.s silenciosa y seproporciona para condiciones que no requieranunatasa de evaporaci6ntan alta.

Indicadordel nivelde agua:

Estehumidificadorest,.equipadocon un medidordel nivel deagua ubicadoenelcentro del paneldecontroles. Cuandoel gabineteest_Ileno deagua,la ventana grandeopuesta a la escalase pondr_.verde. A medida que el agua se vaya con-sumiendo, la cantidad de verde disminuir_,paracorrespondercon la escala.

\

Ivledidorde agua / _ Indicadorde Ilenado

Resecaci6nmanual:

AI final de la temporada de humidificaci6n o siusted no tiene planeadoutilizar el humidificadordurante unasemana o m_.s,puedeanular lafun-ci6n de apagadoautom_.ticopara secar comple-tamenteel gabinetedel humidificador.

Parahaceresto,simplementedesliceel retenedordel flotador, ubicado en la partetrasera del gabi-nete del humidificador, hasta laposici6n superiorde la ranuraen laque est,. ubicado.Estosujetar_.el flotador en posici6n haciaarriba y los ventila-dores funcionar_.nhasta que usted apague launidad.

NOTA:AsegQresede posicionar el retenedor delflotador enel modo de funcionamientonormal (laposici6n m_.sbaja de la ranura) para el funcio-namientodel humidificador.

Eldiagrama siguientecorrespondea la ranura enla que el retenedordelflotador est,. ubicadoen lapartetrasera del gabinete.

Parte trasera del gabinete La posici6n superior

espararesecaci6n

I manUal

J J La posici6n inferior( I,_ es para el modo deL--," lnncionamientonormal

Rannraparael retenedordel conjnnto del brazoarticnlado

23

Page 24: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

Uti/izaci6nde/humidificadorPaso1:

Aseg_resede que el humidificador est_ Ileno deaguay enchufado.

Paso2:

Ajuste el control de velocidad "_" a lavelocidad m&sbaja"o"

Paso3:

Ajuste el control de humedad "_1_" en laposici6n intermedia.

NOTA:El humidificador deberiafuncionar con el

control de humedadenel ajusteintermedio reco-mendado. Si no se pone en funcionamiento, lahumedadest,.aun nivel relativamentealto.

Paraprobar la unidad en estascondiciones, gireel control de humedad completamente en elsentido de las agujas del reloj. Launidad deberiacomenzara funcionar.Despu_sdehaber probadola unidad,ajusteelcontrol de humedadenel nivelintermedio o enel nivel deseado.

Deje que transcurran 24 horas para que elhumidificador seajuste.

Si el nivel dehumedadde la casaes suficiente,elhumidificador funcionar_, solamente con el

control de humedadgirado completamenteen elsentido de las agujasdel reloj.

IIVlPORTANTE:Se pueden producir da_oscausados por agua si se empiezaa formar con-densaci6n en las ventanas o en las paredes. Elajustedel control de humedaddebebajarsehastaque ya no se forme condensaci6n.

Paso 4:

Si el humidificador deja de funcionar y la unidadno est,. vacia, el nivel de humedad est,. en losrequisitos normales para ese ajuste o se est,.ajustando alas condiciones de la casa. La tablaque aparecem_.sadelantemuestra los nivelesdehumedad interior recomendados. La figuramuestra los porcentajes de humedad relativaaproximados que corresponden a los diversosajustesdel control de humedad.

Cuandolatemperaturaexteriores:

-10°F -24°C0°F -18o0

10°F -12°C20° F -6°C

Lahnmedadrelativainterior

recomendadaes:

20%25%30%35%

/%

Consejosdeutilizaci6nparaIograrel mejorrendimiento1. Posicione el humidificador al menosa 2 pul-

gadas (5 cm) de cualquier paredy alejado detodas las salidasde calor.

2. No restrinja la entradani la salidadel flujo deaire del humidificador.

3. UseelbacteriostatoSears32-14900 recomen-

dado pararetardarel crecimientode bacteriasque podria causar olores y podria ser perju-dicial parasu salud.

4. Limpie regularmente el humidificadorsiguiendo las instrucciones de la secci6n"Limpieza y mantenimiento" de estemanual.

5. Reemplacelos filtros de mecha evaporativosal menos una vez por temporada dehumidificaci6n o m_.s, dependiendo de lascondicionesdel agua desu zona.

24

Page 25: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

Reemp/azoy cuidadode losfi/trosADVERTENCIA:Para reducirel riesgo dedescar-gasel6ctricaso lesionescausadaspor laspiezasm6viles, desenchufesiempre el humidificadorantesdequitaro reemplazarcualquierpieza.

_,% TapapivotanteConjunto delosventiladores

//

PRECAUCION: Para ayudar a retardar el creci-miento de bacterias y mantener la m_.ximaeficiencia, se debe reemplazar el filtro al menosuna vez por estaci6n, o m_.sa menudo en condi-clones de agua dura. Use el filtro de repuestorecomendado Kenmore 32-14912.

Gabineledelhumidilicador

JY

Todos los filtros se pueden enjuagar peri6dica-mente pero s61ocon agua limpia. Tengacuidadode no da_ar el papel, Para reemplazar los filtrosde mecha evaporativos del humidificador paratoda la casaKenmore Quiet Comfort, siga estasinstrucciones,

1, Desenchufe el humidificador y proceda alimpiarlo,Antes de quitar los filtros, recomen-damos trasladar el humidificador a un _.readonde los revestimientos del piso no seanpropensosa sufrir da_os por causadel agua,como por ejemplo_,reasde cocinao de ba_o,

2. Paraquitar las piezas:Quiteel conjunto de losventiladores levantandolatapa pivotanteparaabrir la unidad, Agarre la parte delanteracentral y la partetrasera central del conjuntode los ventiladores, Levantedicho conjuntoyp6ngalo a un lado en una superficie plana ylimpia. Unavez hecho esto, se tendr_,accesoalas carcasasde los filtros,

NOTA: Hay dos conjuntos de carcasa de losfiltros. Cada conjunto consiste en una carcasasuperior del filtro y una carcasa delantera delfiltro. La carcasadelanteradel filtro contiene len-g0etas que sujetan la carcasasuperior del filtro,No quite las carcasasdelanterasde los filtros,

3, Paraquitar la carcasasuperior delfiltro, desvielas dos leng0etas verticales ubicadas en lapartesuperiorde lacarcasadelanteradel filtroy levante la carcasahaciaarriba y haciafueradel gabinete.Con un pa_o absorbentesuave,quite de los conjuntosde carcasade losfiltrostoda el agua que quedeo todos los dep6sitosminerales sueltos que no est_n atrapados enel filtro,

4, Saque los dos filtros y des_chelos. Repitaelprocedimiento para la otra carcasasuperiordel filtro, Limpie las piezas internas delhumidificador siguiendo las instrucciones dela secci6n "Limpieza y mantenimiento" deeste manualdel usuario,

25

Carcasassuperiores Retenedordeldelosfiltros conjuntodel

brazoarticuladoY

Lengiietade la carcasadelanteradel filtro

Conjuntodelflotador

Partedelanteradelhumidificador

(vistadesdearriba)

Brazo de

_ empuje X

Brazo pivote

del llotador

Retenedor del )

¢onjunto delbrazoarticulado

_ Flotador

Vista despiezadadel conjunto del flotador

Page 26: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

Reemp/azoy cuidadode los fi/tros(continuaci6n)5. a. Instale un filtro nuevo (32-14912) en el

fondo del gabinete. /_ Lengiietas

NOTA: Los filtros nuevos cabr_.nsolamente deuna maneraenel gabinete.Fijeseen los detallesdel interior del gabinete donde los filtros seasientan. Cadapar de filtros se debe posicionarde modo que las gotas de adhesivo est_n

orientadas hacia fuera unas respecto a otras. _ /Consultela Figura5a. Carcasadelanteradelfiltro

b. Coloque los filtros en el fondo del gabinetede modo que los pliegues abiertos sedeslicensobre las lengiJetasubicadasen elfondo del gabinete.Repitael procedimientoparael otro lado.

c. Reposicione las carcasassuperiores de losfiltros sobre la partede arriba de los filtrosy ac6plelas a presi6n en las carcasasdelanterasde los filtros.

d. Posicione el conjunto de los ventiladoressobre elgabinete.AsegQresedequeel tuboVenturi de los ventiladores (la secci6ncilindrica m_.sbaja ubicada debajo de losventiladores) est_ colocado dentro de lascarcasassuperiores de los filtros.

e. Pongalatapa pivotante enposici6n cerradasobreel conjunto de los ventiladores.

f. La unidad est,. lista para utilizarse o paraalmacenarsepara la pr6xima temporada.

Parte delantera del humidificador

Figura 5a. Las ubicacionesde los filtros est_n marcadascon una X

Carcasassuperiores Retenedordeldelosfiltros conjuntodel

..........brazoarticulado/

Lengiietade la carcasadelanteradel filtro

Conjuntodelflotador

Partedelanteradelhumidificador(vistadesdearriba)

26

Page 27: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

Limpiezay mantenimientoADVERTENCIA:Para reducir el riesgo delesiones, incendio o da_os al humidificador,utilice _nicamente limpiadores recomendadosespecificamente para humidificadores. Noutilice nunca materiales inflamables,combustibles o t6xicos para limpiar elhumidificador. Para reducir el riesgo dequemarse y de da_ar el humidificador, noponganunca agua calienteen el humidificador.

PRECAUCION:La purezadel agualocal variadeuna zona a otra y en ciertas condiciones lasimpurezascontenidasenelagua y las bacteriassuspendidas en el aire pueden fomentar elcrecimiento de microorganismos en eldep6sitodel humidificador.

Para retardar el crecimiento de bacterias quepuedencausarolores y ser perjudicialespara lasalud, utilice _nicamente filtros de repuestoKenmore. Tambi_n recomendamos utilizar elbacteriostato32-14900 aprobado por la EPAyel limpiador para humidificadores21-1473, loscualesse puedenconseguir en su tienda localSears.

NOTA:Si es necesario utilizar un bacteriostatoaprobado, siga correctamente lasinstrucciones.

El gabinete del humidificador para toda la casatiene capacidad para4-3/4 galones de agua.

Paso1:

Para facilitar la limpieza, el gabinete del humi-dificador se debe vaciar y secar completa-mente. Para Iograr esto, use el m_todosiguiente:

a. En el lado trasero del gabinete del humidifi-cador, Iocaliceel retenedor del flotador. En elmodo de funcionamiento normal, elretenedor estar_, posicionado en la parteinferior de la ranura ubicada en el gabinete.Empuje el retenedor hacia arriba hasta laposici6n superior de la ranura del gabinete,

ADVERTENCIA:Para reducir el riesgo de des-cargas el@tricas, desenchufe siempre elhumidificador antes de limpiarlo o hacerleservicio de ajustes y reparaciones. Si elhumidificador no est,. desenchufado, elventilador podria ponerse en marcha despu_sdequitar la carcasa.

hasta que quede bloqueado en esaposici6n.(Consulte la secci6n "Resecaci6n manual"en la p_.gina23.)

b. Dejeque el humidificador funcione hasta queno quedeagua en el gabinete.

c. Desenchufeel humidificador.

Paso2:

Paraquitarlaspiezasa. Quite el conjunto de los ventiladores levan-

tando la tapa pivotante para abrir la unidad.Agarre la parte delantera central y la partetrasera central del conjunto de los ventila-dores. Levante dicho conjunto y p6ngalo aun lado en una superficie plana y limpia.

b. Antes de quitar las piezas internas delgabinete del humidificador, recomendamostrasladar el humidificador a un _.readondelos revestimientos del piso no seanpropensos a sufrir daSos por causa delagua,como por ejemplo un_.readecocina ode ba_o.

c. Desvielas dos lengi.ietasverticales ubicadasen la parte superior de la carcasa delanteradel filtro para soltar la carcasa superior delfiltro. Levante la carcasa superior del filtrodirectamente hacia arriba y hacia fuera delgabinete. Repita el procedimiento para laotra carcasasuperior del filtro.

d. Saque los filtros viejos y des_chelosapropiadamente.

e. Saque el flotador del nivel de agua delgabinete del humidificador comprimiendo elretenedor del flotador para soltarlo delgabinete. El gabinete debe estar vacio antesde limpiarlo. El gabinete consiste en las_.reas inferiores del humidificador dondeest_.n los filtros durante el tiempo defuncionamiento normal.

f. Vacie el gabinete hasta que no quede nadade agua.

g. Vaya a "Mantenimiento cada dos semanas"o "Mantenimiento de final de temporada" yluego contin@ tal como se describe acontinuaci6n.

Paso3:

Instale los filtros nuevos (filtros de repuestoKenmore 32-14912) en la ubicaci6n dondeestaban posicionados los filtros viejos.Reinstale el conjunto del flotador del nivel deagua en el gabinete.NOTA: El retenedor del conjunto del brazoarticulado debe estar posicionado en el modo

27

Page 28: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

Limpiezay mantenimientode funcionamiento normal. Aseg_rese de queest_ posicionado en la parte inferior de laranura ubicada en la parte trasera del gabinete(vea el diagrama de la ranura que apareceen lap_.gina23).Reposicione la carcasa superior de los filtrossobre la parte superior de los filtros y ac6plelaa presi6n sobre las carcasas delanteras de losfiltros. Posicione el conjunto de los ventiladoressobre la parte superior del gabinete y devuelvael humidificador a la ubicaci6n deseada parautilizarlo.

Rellene el gabinete del humidificador con agualimpia y fria. Enchufe la unidad en untomacorriente de 120 V C.A. y ajuste loscontroles siguiendo las instrucciones de lasecci6n "Utilizaci6n de los controles delhumidificador" de este manual.

MantenimientocadadossemanasRemociOndecostra

1. Llene la base del humidificador con una

tazade240 ml (8 onzas)devinagre blancosin diluir. Dejeque la soluci6n permanezcaen la basedurante 20 minutos.

2. Limpie todas las superficies interiores conun cepillo blando. Humedezca un patiosuave con vinagre blanco sin diluir ylimpie la base con el patio para quitar lacostra.

3. Enjuague a fondo con agua templada ylimpia para quitar la costra y la soluci6nlimpiadora antes de desinfectar elgabinete.

4. Quite el polvo del conjunto de los ventila-dores y las superficies exteriores con unpatio suave solamente.

(continuaci6n)Mantenimientodefinalde temporada1. Siga las instrucciones de "Mantenimiento

cada dos semanas" al final de la temporadade humidificaci6n.

2. Saque y tire los filtros.

3. Deje que el humidificador se sequecompletamente antes de guardarlo. Noalmacene la unidad con agua dentro delgabinete.

4. Guarde el humidificador en un lugar frescoy seco.

5. Instale un filtro nuevo en el humidificador

limpio antes de que comience la pr6ximatemporada.

6. El procedimiento de "Mantenimiento cadados semanas" tambi_n se recomienda siusted no piensa utilizar el humidificadordurante una semana o m_.s.

DesinfecciOn del gabinetedel humidificador

1. Llene el gabinete del humidificador con 1cucharadita de blanqueador de cloro en1 gal6n de agua. Deje que la soluci6npermanezca en la base durante 20 minu-tos, agit_.ndola cuidadosamente cadapocos minutos. Moje todas las superficiesque normalmente est_n expuestas a agua.

2. Vacie el gabinete del humidificadordespu_s de 20 minutos. Enju_.gueloconagua hasta que el olor a blanqueador hayadesaparecido. Dejeque la unidad se sequecompletamente. 28

Page 29: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

Resoluci6ndeproblemas

Problema

La unidad no funciona.

La unidad no se apaga.

La unidad no se seca

completamente.

Causaprobable

• Se ha establecido el nivel dehumedad seleccionado.

• No hayalimentaci6n el_ctrica.

• El retenedor del flotador estA

ubicado en la posiciOnde"ResecaciOnmanual".

• El flotador no est_ libre.

• Una peque_acantidad de aguapermanece en el gabinete cuandoel indicador del nivel de aguaindica FILL (LLENAR).

Remedio

Subael ajuste del higrostatosi Io desea.

Compruebesi lafuente dealimentaci6nde 120 V suministracorriente.

• Deslice el retenedor del conjuntodel brazo articulado hasta la

posiciOn m_s baja en la ranuraubicada en la parte trasera delgabinete (consulte la p_gina 23).

• Libere el flotador de laobstrucci6n.

Posicione el conjunto del flotadoren la posici6n de "Resecaci6nmanual" (consulte la p_gina 23).

La unidad no se vacia durante • Filtros sucios. • Cambie los filtros usando filtrosel uso. totalmente nuevos.

Sale agua por la parte traserade la unidad.

• Se salpica agua durante elIlenado.

• Los filtros interfieren con elflotador.

El medidor del nivel de agua nofunciona correctamente.

Eche el agua de Ilenado de modoque se desvie en el centro delprotector contra salpicaduras.No Ileneexcesivamente la unidad,pasada la etiqueta de "Full"(Lleno) del gabinete.

AsegQrese de que los filtros est_nposicionados correctamente en elfondo del gabinete (consulte lap_gina 25).

PRECAUCION:Utilice t_nicamenteun bacteriostato registrado por EPA32-14900, que se puede obtener en unatienda minorista Sears.

La utilizaci6n de otros productos de tratamiento de agua podria da_ar los elementos del filtro.En ninguna circunstancia debe usted usar productos de tratamiento de agua dise_ados para humidificadoresde rotocorrea o ultras6nicos.

29

Page 30: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

PiezasderepuestoListade piezasdel humidificadorKenmore

No. de modelo144162

J2

I_ _

i

j4

7

30

Page 31: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

PiezasderepuestoListade piezasdel humidificadorKenmore

No. de modelo144162Pidasiempreporn_merodepieza,noporn_merodeclave

No. de No. de

clave pieza Descripci6n

1 828741-2 Tapaestacionaria

2 828742-0 Tapa pivotante

3 832308-0 Conjunto de controles

4 828199-8 Gabinete

5 823726 Riel protector

6 STD601107 * Tornillo de cabeza troncoc6nica tipo"AB" No. 10 x 3/4

7 828515 Ruedecilla doble

8 828195-0 Soporte del filtro inferior

9 32-14912 1-Filtro evaporativo

10 828534-0 Soporte del motor

11 828115-0 Motor

12 822406-1 Ventilador

13 828194-0 Soporte del filtro superior

14 824101-0 Retenedor del flotador

15 828200-3 Flotador del nivel de agua

-- SP6595 Manual del usuario (no ilustrado)

NOTA:Todo intento de reparar el conjunto de los controles o el motorpuedecrear un peligro, a menos que la reparaci6n searealizadapor un t_cnico de servicio calificado. El servicio dereparacionesest,. disponible en latienda Searsm_.scercana.

* Articulo de herrajes est_.ndar.Se puede comprar Iocalmente.

1 Articulo de existencias. Se puede conseguir a trav_s deldepartamento de ferreteria de la mayoria de las tiendas minoristasSears.

31

Page 32: WHOLE HOUSE HUMIDIFIER - Sears Parts DirectSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Part No. SP6595 Printed in U.S.A. ONE YEAR FULL WARRANTY ON KENMORE HUMIDIFIER If

Your HomeFor expert troubleshooting and home solutions advice:

manage homewww.m anagemyhome.com

For repair - in your home - of all major brand appliances,lawn and garden equipment, or heating and cooling systems,

no matter who made it, no matter who sold it!

For the replacement parts, accessories andowner's manuals that you need to do-it-yourself.

For Sears professional installation of home appliancesand items like garage door openers and water heaters.

1-800-4-MY-HOME @ Call anytime, day or night

(1-800-469-4663) (USA and Canada)

wry.sears.corn www.sears.ca

Our Home

For repair of carry-in items like vacuums, lawn equipment,and electronics, call anytime for the location of the nearest

Sears Parts & Repair Service Center

1-800-488-1222 (USA) %800-469-4663 (Canada)www.sears.corn www.sears.ca

To purchase a protectionagreement on a productserviced by Sears:

1-800-827-6655 (USA) 1-800-361-6665 (Canada)

Para pedirser,_iciode reparaci6n Au Canada pourserviceen francis:a domicilio,y paraordenarpiezas: 1.800.LE.FOYERMC

1-888-SU-HOGAR® (I-800-533-6937)(1_88-7844S427) www sears ca

© SearsBrands, LLC

® Registered Trademark/TMTrademark/sM Service M ark of Sears Brands, LLC

_SMarca Registrada / T_aMarca de Fabrica / SMMarca de Sewicio de Sears Brands, LLC

MCMarque de commerce/M_ Marque deposee de Sears Brands, LLC

Part No. SP6595 Form No. SP6595-1 Printed in U.S.A. 12/09