which radio is about to fail due to reactive maintenance?€¦ · with the diagnostx ota waveform...

15
Which radio is about to fail due to Reactive Maintenance?

Upload: others

Post on 04-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Which radio is about to fail due to Reactive Maintenance?€¦ · with the DiagnostX OTA Waveform Analyzer . Next Generation DiagnostX US Patents: 8565096, 8948022, 9282482, 8600371,

Which radio is about to fail due to

Reactive Maintenance?

Page 2: Which radio is about to fail due to Reactive Maintenance?€¦ · with the DiagnostX OTA Waveform Analyzer . Next Generation DiagnostX US Patents: 8565096, 8948022, 9282482, 8600371,

Proactive preventative maintenance can tell

with the DiagnostX OTA Waveform Analyzer

Page 3: Which radio is about to fail due to Reactive Maintenance?€¦ · with the DiagnostX OTA Waveform Analyzer . Next Generation DiagnostX US Patents: 8565096, 8948022, 9282482, 8600371,

Next Generation DiagnostX

US Patents: 8565096, 8948022, 9282482, 8600371, 8825042, 9432866. Other patents pending.

TM

Page 4: Which radio is about to fail due to Reactive Maintenance?€¦ · with the DiagnostX OTA Waveform Analyzer . Next Generation DiagnostX US Patents: 8565096, 8948022, 9282482, 8600371,

DiagnostX is an over-the-air radio analyzer – the only one on the market. DiagnostX monitors the base station RECEIVE frequency, analyzing all control channel transmissions from the subscriber radios on the system.

4

Page 5: Which radio is about to fail due to Reactive Maintenance?€¦ · with the DiagnostX OTA Waveform Analyzer . Next Generation DiagnostX US Patents: 8565096, 8948022, 9282482, 8600371,

Operation

• Connect to an AC power source (100-240V, 50-60 Hz)

• Connect to an antenna: RX antenna at the multi-coupler or stand-alone antenna

• Enter Control Channel frequencies

• Define Thresholds

5

Registration

Group Affiliation

PTT

DiagnostX Viewer Console

Page 6: Which radio is about to fail due to Reactive Maintenance?€¦ · with the DiagnostX OTA Waveform Analyzer . Next Generation DiagnostX US Patents: 8565096, 8948022, 9282482, 8600371,

Stand-alone or System-wide Coverage

• DiagnostX DX-2002 can be used as a stand-alone unit, or it can be extended with up to three NX-200 remote receivers

• Data from the NX-200 units are sent to the DX-2002 via IP connectivity

6

Page 7: Which radio is about to fail due to Reactive Maintenance?€¦ · with the DiagnostX OTA Waveform Analyzer . Next Generation DiagnostX US Patents: 8565096, 8948022, 9282482, 8600371,

System-wide Coverage

7

NX-200

NX-200

IP Backhaul

NX-200

NX-200

DiagnostX Viewer Console

Page 8: Which radio is about to fail due to Reactive Maintenance?€¦ · with the DiagnostX OTA Waveform Analyzer . Next Generation DiagnostX US Patents: 8565096, 8948022, 9282482, 8600371,

DiagnostX is Protocol and Frequency Band Specific

Available Protocols: • P25 Trunked • P25 Conventional • SmartNet™/SmartZone™ • MOTOTRBO • EDACS • NXDN

Available Frequencies: • VHF (136-174)

• UHF (380-430 or 450-470 or 470-512)

• 700 MHz • 800 MHz • 900 MHz

8

Page 9: Which radio is about to fail due to Reactive Maintenance?€¦ · with the DiagnostX OTA Waveform Analyzer . Next Generation DiagnostX US Patents: 8565096, 8948022, 9282482, 8600371,

P25 Metrics and Measurements

1. Frequency Error

2. Symbol Error 600, Symbol Error 1800

3. Maximum Frequency Deviation

4. Modulation Fidelity

5. BER (on a per transmission basis, %)

6. RSSI (on a per transmission basis, dBm)

7. SNR (on a per transmission basis)

8. Reserve Gain at the multi-coupler (dBm)

9

Page 10: Which radio is about to fail due to Reactive Maintenance?€¦ · with the DiagnostX OTA Waveform Analyzer . Next Generation DiagnostX US Patents: 8565096, 8948022, 9282482, 8600371,

Failed Evaluation List

10

Page 11: Which radio is about to fail due to Reactive Maintenance?€¦ · with the DiagnostX OTA Waveform Analyzer . Next Generation DiagnostX US Patents: 8565096, 8948022, 9282482, 8600371,

Transmissions

11

Page 12: Which radio is about to fail due to Reactive Maintenance?€¦ · with the DiagnostX OTA Waveform Analyzer . Next Generation DiagnostX US Patents: 8565096, 8948022, 9282482, 8600371,

Reports

12

Page 13: Which radio is about to fail due to Reactive Maintenance?€¦ · with the DiagnostX OTA Waveform Analyzer . Next Generation DiagnostX US Patents: 8565096, 8948022, 9282482, 8600371,

Waveform Visualization

13

Page 14: Which radio is about to fail due to Reactive Maintenance?€¦ · with the DiagnostX OTA Waveform Analyzer . Next Generation DiagnostX US Patents: 8565096, 8948022, 9282482, 8600371,

Benefits of DiagnostX 1. Ensures operational readiness - measures radio alignment

constantly

2. Reduces maintenance costs by addressing only radios out of specification

3. The ideal complement to an auto-tune service monitor

4. Indispensible P25 migration tool

5. Completely autonomous from the radio system

14

Page 15: Which radio is about to fail due to Reactive Maintenance?€¦ · with the DiagnostX OTA Waveform Analyzer . Next Generation DiagnostX US Patents: 8565096, 8948022, 9282482, 8600371,

Proactive Efficient Proven

15

More information available by calling LocusUSA 321-727-3077

www.locususa.com/products/diagnostx