I. Lightning Protection System
II. Surge Protection Device
III. Grounding System
IV. Obstruction & Signal Lights
V. Energy- saving Fluorescent
Lamp
VI. Product Selection Guide
WHAT’S INSIDE…
Lightning Protection
This lightning conductor is based on the principle of the spreading of
electromagnetic waves. Lightning conductor consists of capturing end, ion
generators, lightning conductor crown, electrodes, triggering circuit,
grounding cable connector and the pole connector components. These
components have been manufactured using the best materials defined by
the standards. Except for the grounding cable connector (which is made of
copper, and coated with chromium) all other components are made of
stainless material resistant to atmospheric corrosion. The ion generator and
the triggering circuit have been frozen with a special material inside the
cone-like stainless crown, thus protected against humidity.
2
Detakom-A5
Early Streamer Emission
(ESE)
Lightning Protection
7
LOCAL COMPANIES USING DETAKOM-A5
COMPANY LOCATION
1. PARKLANE INTERNATIONAL HOTEL Cebu City
2. NESTLE PHILIPPINES Lipa City
3. PRES. ESTRADA RESIDENCES AND LIBRARY Tanay, Rizal
4. CITYWALK 2 Libis, QC
5. AT & E TECHNICAL Pampanga
6. NORTH TRIANGLE CENTER Quezon City
7. TROPICAL HUT MALL Bulacan
8. HOLY FAMILY SCHOOL UP Village, Quezon City
9. ASSUMPTION COLLEGE San Lorenzo Village, Makati City
10. UNIVERSITY OF CORDILLERA Cordillera
11. RUSTY LOPEZ BLDG. Marikina City
12. HARDROCKS AGGREGATES Makati City
13. SAUDI EMBASSY Makati City
14. MACAPAGAL HOME DEPOT Pasay City
15. SHELL STATION Macapagal, Pasay City
16. PUREGOLD Baliwag
17. MERALCO Substation Baliwag
18. MERALCO Substation Gaya-gaya
19. MERALCO Substation Marikina
20. MERALCO Repeater Banoy
21. MERALCO Substation Plaridel
22. SOGO HOTEL Banawe, Quezon City
23. ZUBIRI RESIDENCE Dasmarinas, Village
24. LUSTER MFG. CORP Lima, Batangas
25. MITSUBA MFG. Dasmarinas, Cavite
26. ST. JAMES HOSPITAL Sta. Rosa, Laguna
27. ST. JOSEPH HIGHSCHOOL Paranaque
28. RTG URBAN BUILDERS Quezon City
Lightning Protection
8
LOCAL COMPANIES USING DETAKOM-A5
COMPANY LOCATION
29. AYALA GROVE Silang, Cavite
30. THE PRESIDENT TOWER Timog, QC
31. NAGA APARTELLE Naga City
32. PUREGOLD Taytay, Rizal
33. SOGO HOTEL Quezon Avenue, QC
34. CEBU BOARDWALK Cebu City
35. PUREGOLD Agora, San Juan
36. NAGA COLLEGE Naga City
37. SUPREME STEEL Bulacan
38. FRANCESCA ROYALLE Novaliches, Quezon City
39. PAGADIAN MALL Pagadian City
40. SOLID CEMENT Theresa, Rizal
41. TAGAYTAY RESIDENCE Tagaytay City
42. WORLDTRADE CENTER Pasay City
43. SAN MIGUEL CORP. Cabuyao, Laguna
44. CLARET SCHOOL Quezon City
45. PREMIUM BANK OF ASIA San Juan
46. MERALCO Substation GMA Cavite
47. CAPITOL BLDG. Catarman, Northern Samar
48. WORLD PRECISION GAS CORP Sariaya, Quezon
49. SILANG MUNICIPAL HALL Silang, Cavite
50. NEW BACOLOD CITY GOVERNMENT CENTER Bacolod City
51. VICTORIA TOWER Edsa, Quezon City
52. QUEZON CITY GENERAL HOSPITAL Quezon City
53. ABSOLUT CHEMICAL Lian, Batangas
54. MANILA NORTH TOLLWAYS CORPORATION Malinta, Meycauayan & Bocaue, Bulacan
55. BISCOM Binalbagan, Negros
56. ONE MIHO PLACE Binondo, Manila
Surge Protection
9
MAINS SURGE DIVERTER
ULTIMATE PERFORMANCE IN SURGE SUPPRESSION FOR
MAIN AND BRANCH PANELS.
All mode protection – LEPS MSD series surge diverters provide state-of-the-art protection
for main or branch panels using any power distribution systems such as TT, TN-C, or TN-S, etc.
It offers L-N, L-E, and N-E, repeated protection in lightning intense environment by rapidly
diverts excess transient surges to ground, away from your sensitive equipment.
Highest safety standard design – It has been engineered to the industry’s safest criteria
for full compliance with UL1449 Edition2 by using a specially designed metallic enclosure. Also
with its patented thermal and short circuit fusing included, it ensures safe isolation during
sustained abnormal over-voltage events and component failure.
Exceptional high surge handling capability up to 140ka per line (280ka per
phase) – Its 200ka to 560ka unit total unparalleled surge handling capability makes MSD series
protector the ultimate choice for total facility protection.
Staged LED status indication – all models have two LED indicators per phase to monitor
the integrity of protection. This pre-failure warning indication design means you will never be
unprotected.
Remote monitoring – all models features voltage free contacts with normal open/normal
close contacts which change state to indicate a fault. It can be interfacing with intelligent
building management systems for remote indication.
Redundant protection segments – Each phase employs two independent fused and
thermal overload protection elements to provide back-up protection for continued equipment
survival despite a fault condition. This means that in the event of a fault situation, you are
never left unprotected.
Remote monitoring panel (RMP) – Apart from the built-in LED status indication and
voltage free change over alarm, an optional Remote Monitoring Panel can be chosen which
offers both visual and audible alarm at remote location from the protector.
Surge Protection
10
DESCRIPTION PARAMETER
Nominal Voltage 220vms(1ph), 380vrms(3ph)
Operating Voltage 180-220vrms(1ph), 300-480vrms(3ph)
Frequency 40-60hz
Earth Leakage Current 10µa
Max. Surge rating per phase:
MSD1-50M
MSD1-80M
MSD1-140M
MSD3-50M
MSD3-80M
MSD3-140M
50ka(8/20µs)(100ka per phase)
80ka(8/20µs)(160ka per phase)
14ka0(8/20µs)(280ka per phase)
50ka(8/20µs)(200ka per phase)
80ka(8/20µs)(320ka per phase)
140ka(8/20µs)(560ka per phase)
Let through voltage <750v for 3ka Cat B
Protection Mode L-N, L-E, N-E
Response Time <5ns
Standards Compliance
BS6651-1999 cat A.B.C
AS1768-2003 cat A.B.C
IEEE C62.41 cat A.B.C
CP33-1999 cat A.B.C
IEC 1000-4-5 1995
UL1449 second edition
Alarm Isolation 4kv
Status Indicator LED (Green=OK)
Optional Remote Alarm Siren sound, OK and FAILED
Alarm (volt free contact) N/O, N/C(2A@250vac)
Alarm Conductor Size 2.5mm²
Conductor Size 16mm²
Operating Temperature -40-85ºC
Humidity 0-95%(r.h.)
Mounting 35mm DIN rail (DIN 43880) or panel screw mount
Enclosure Material Galvanized steel alloy
Specifications
MAINS SURGE DIVERTER
Surge Protection
9
MAINS DINRAIL DIVERTER GOOD PERFORMANCE IN SURGE SUPPRESSION
FOR BRANCH PANELS IN INDUSTRIAL AND
COMMERCIAL ENVIRONMENTS LOCATED IN
LOW TO MEDIUM EXPOSURE AREAS.
All mode protection – LEPS MDD series surge diverters provides state-of-the-art protection
for branch panels using any power distribution systems such as TT, TN-C or TN-S etc. It offers
L-N, L-E, and N-E, repeated protection in lightning intense environment by rapidly diverts
excess transient surges to ground, away from your sensitive equipment.
Highest safety standard design – It has been engineered to the industry’s safest criteria
for full compliance with ULI1449 Edition2 by using a specially designed aluminum enclosure.
Also with its patented thermal and short circuit fusing included, it ensures safe isolation during
sustained abnormal over-voltage events and component failure.
High surge handling capability up to 120ka per line (240ka per phase) -120ka
per line (240ka per phase) surge handling capability makes MDD series protectors an economical
choice for total facility protection.
LED status indication – All models have LED indicators per phase to monitor the integrity
of protection.
Remote monitoring – All models features voltage free contacts with normal open/normal
close contacts which change state to indicate a fault. It can be interfacing with intelligent
building management systems for remote indication.
Redundant protection segment – 80ka or above models employs two to three
independent fused and thermal overload protection elements to provide back-up protection for
continued equipment survival despite a fault condition. This means you are never left
unprotected.
Remote monitoring panel (RMP) – Apart from the built-in LED status indication and
voltage free change over alarm, an optional Remote Monitoring Panel can be chosen which
offers both visual and audible alarm at remote location.
Fits into most switching box – its compact design match the profile of most common
MCBs at used which makes it ideal for inclusion in distribution or switchboard by mounting on
the DIN43880 DIN rail.
Surge Protection
10
DESCRIPTION PARAMETER
Nominal Voltage 220v (1ph), 380v (3ph)
Operating Voltage 180-280v (1ph), 300-480v (3ph)
Frequency 40 to 60hz
Earth Leakage Current 10µa
Max Surge Rating per Line & Weight
MDD1-25m (single-phase)
MDD1-40m
MDD1-80m
MDD1-120m
MDD3-25m (three-phase)
MDD3-40m
MDD3-80m
MDD3-120m
1ph, 25ka
1ph, 40ka
1ph, 80ka
1ph, 120ka
3ph, 25ka per line, 50ka per phase
3ph, 40ka per line, 80ka per phase
3ph, 80ka per line, 160ka per phase
3ph, 120ka per line, 240ka per phase
Let Through Voltage <850v for 3ka Cat B
Protection Mode L-N, L-E, N-E
Response Time <5ns
Standard Compliance
BS6651-1999 cat A.B.C
AS1768-2003 cat A.B.C
IEEE C62.41 cat A.B.C
CP33-1999 cat A.B.C
IEC 1000-4-5 1995
UL1449 second edition
Alarm Isolation 4kv
Status Indicator LED (Green = OK)
Optional Remote Alarm Siren sound, OK and FAILED
Alarm (Volt Free Contact) N/O, N/C(2A@250vac)
Alarm Conductor Size 2.5mm²
Conductor Size 16mm²
Operating Temperature -40 to 85ºc
Humidity 0 to 95% (relative humidity)
Mounting 35mm DIN rail (DIN 43880) or panel screw mount
Enclosure Material Anodized aluminum
Specifications
MAINS DINRAIL DIVERTER
Surge Protection
11
COAXIAL LAN/CCTV PROTECTOR PROTECTS COAXIAL LAN, SECURITY & TRAFFIC
CAMERAS, VIDEO RECORDERS AND BROADCAST
EQUIPMENT IN THE FIELD FROM LIGHTNING
TRANSIENTS AND SURGES
Multi-stage design for better protection – CLP series coaxial protectors use multi-
stage design by employing a combination of high energy gas discharge tube, ultra fast diodes
and SAD which ensures excellent protections without impairing system performance.
High sure rating and bandwidth – with its 20ka surge handling capability and 20mhz
high bandwidth, it can provide the safest protection lightning intense environment and also
ensures a smooth signal traffic.
All mode protection – transients appear between the inner conductor of a coaxial cable
and its screen, and also between the cable’s screen and the terminal’s frame ground can lead
to the damage of the semiconductors and integrated circuits of the sensitive equipment. CLP
protectors offer both transverse and common mode protection which ensures all the risks are
eliminated.
Very low let-through voltage – the semiconductor and ICs inside the LAN terminals and
video equipment are particularly vulnerable to surge and transients overvoltage that introduced
by nearby lightning activities and heavy load switching events. With CLP protector, 14v low let-
through voltage is achieved which ensures the safety of the equipment whilst maintaining high
quality signals.
Safety current fusing design – a safety series current fuse was purposely incorporates to
ensure the surge arresting elements can absorb maximum energy while in the event of failures
will automatically open to isolate the damaged parts.
Full range connectors – a wide range of connector types are available including BNC, F,
TNC, N-type SMA, SMB and UHF to suit all application requirements.
Surge Protection
12
DESCRIPTION PARAMETER
Max. Working Voltage 8v
Max. Operating Current 300ma
Max. Surge Current 20ka(8/20µs)
Let through voltage
(at 5kv, 10/700µs)
14v (signal to screen)
320v (signal/screen to earth)
VSWR ≤1.1:1
Insertion Loss (dc) ≤1 db at 20mhz
Response Time <5ns
Bandwidth:
(-3db 75Ω system) ≥20mhz
In-line Resistance 3.9Ω
Cable Impedance Suitable for 50 and 75Ω
Standards Compliance
BS6651-1999 Cat A.B.C
AS1768-2003 Cat A.B.C
IEC 61643-21
ITU (CCITT) 1X K17
CP33-1996 Cat A.B.C
UL497B
EMC Compliance BS EN 60950:1992
BS EN 61000-6-2:1999
Earth Connection Flying ground lead
Mounting Via optional bracket or DIN clip
Enclosure Material Anodized aluminum
Operating Temperature -40-85ºC
Humidity 0-95%(R.H.)
Altitude 0-3650m
Specifications
COAXIAL LAN/CCTV PROTECTOR
Surge Protection
COMPUTER NETWORK PROTECTOR
PROTECTS SENSITIVE COMPUTER NETWORKS
LIKE ROUTER, HUBS, SWITCHES, PC
WORKSTATIONS USING 10/100/1000 BASET,
CCDI, ATM155 AGAINST LIGHTNING INDUCED
SURGES, AC POWER INTERFERENCE AND
GROUND LOOP ENERGIES.
Single-port or multi-port protection – LPP series of computer network protectors
offers a flexible surge protection solution that can grow with your requirements. It is available
for single port computer terminal protection and multiport protection with maximum of 24
port, 19” rack mounting applications such as hubs, routers, switches, ATMs using RJ45
connectors.
Versatile Ethernet system protection(CAT5, CAT5e, CAT6, Power-over-
Ethernet) – LPP series are designed to protect all widely used computer network system using
Ethernet twisted pairs technology like 10/100/1000 BaseT, CDDI, ATM155 and also other Power-
over-Ethernet.
All mode protection – Transient overvoltage due to lightning induced surges, AC power
interference and ground loop energies appearing between any signal pair and/or its ground can
damage the sensitive network equipment, LPP series protector are uniquely designed to protect
both common and differential mode in all the 8 pins of the RJ45 port and its ground lead.
State-of-the-art avalanche diode technology – The sophisticated hybrid circuitry
using Silicon Avalanche diode ensures very fast response time and exceptional low let-through
voltage which results in maximum system reliability and up-time.
Low shunt capacitance and in-line resistance to reduce signal loss – With only
5pF shunt capacitance and negligible in-line resistance, even the most demanding high speed
gigabit multimedia signal can be passed without much signal degradation.
Simple plug-in installation – The compact, in-line and simple plug-in design enables it to
be easily located near to the protected equipment. When multiport protection is required, the
19” rack-mounting models can be used which can hold up to 24 ports and only occupying 2U
space.
Surge Protection
14
DESCRIPTION PARAMETER
Max. Working Voltage 5v
Max. Operating Current 300ma
Protection Modes Common and transverse
Lines Protected All pairs
Response Time 5ns
Max. Surge Rating 100a(8/20µs)
Max. Data Rate 100mb/s (C5, PoE models)
1000mb/s (C6 models)
Let through Voltage 23v (at 5kv 10/700µs)
Shunt Capacitance 5pf (single port models)
25pf (rack-mount models)
In Line Resistance ~0Ω
Standards Compliance
100BaseT
1000BaseT
CAT5
CAT5e
CAT6
Connector Type RJ45
Earth Connection Flying lead (single port models)
Earth stud (rack-mount models)
Specifications
COMPUTER NETWORK PROTECTOR
Surge Protection
15
TELECOM LINE PROTECTOR PROVIDES SUPERIOR LIGHTNING AND SURGE
PROTECTION FOR TELECOMMUNICATION
LINES LIKE PSTN, ISDN, DDN AND DSL USING
TWISTED PAIR
Single-port or multi-port protection – TLP series of telecommunication lines protectors
offers a flexible surge protection solution that can grow with your requirements. It is available
for single port telecom terminal protection and multiport protection with maximum of 24 port,
19” rack mounting applications using RJ45 or RJ11 connectors.
Versatile telecom lines protection – TLP series are designed to protect all widely used
telecommunication lines like PSTN, ISDN, DDN and xDSL system using twisted pairs. Different
connectors like RJ45, RJ11 and British plug/socket are available.
All mode protection – Transient overvoltage due to lightning induced surges, AC power
interference and ground loop energies appearing between any signal pair and/or its ground can
damage the sensitive telecommunication equipment. TLP series protector are uniquely designed
to protect both common and differential mode in all the connected pins of the RJ45 port orRJ
11port and its ground lead.
Multi-stage protection offers exceptional safety – TLP series are multi-stage design
which employed sophisticated hybrid circuitry by using a combination of high energy gas
discharge tube, ultra fast diodes and SAD which results in maximum system reliability and up-
time.
High surge rating & bandwidth – With its 20ka surge handling capability and 20mhz high
bandwidth, it can provide the safest protection in lightning intense environment and also
ensures a smooth data traffic.
Simple plug-in installation – The compact, in-line and simple plug-in design enables it to
be easily located near to the protected equipment. When multiport protection is required, the
19” rack-mounting models can be chosen which can hold up to 24 ports and only occupying 2U
space.
Surge Protection
16
DESCRIPTION PARAMETER
Max. Working Voltage
(Line to line)
190v (PSTN)
60v (ISDN)
68v (DDN)
50v (Xdsl)
Max. Operating Current 150ma
Protection Modes Common and transverse
Lines Protected 2 wires(RJ11-pins 3&4, RJ45-pins 45)
4wires(RJ11-pins 3&4, RJ45-pins 4&5, 3&6)
Response Time <5ns
Max. Surge Rating 20ka(8/20µs)
Max. Data Rate 20mb/s
Let through Voltage
(at 5kv 10/700µs)
220v (PSTN)
80v (ISDN)
78v (DDN)
60v (xDSL)
Shunt Capacitance <150pf
Insertion Loss
(at 144khz) <0.2db
In Line Resistance 3.9Ω
Standards Compliance
BS6651-1999
AS1768-2003
IEC61643-21
ITU(CCITT) 1x K17
Connector Type RJ45 or RJ11
Earth Connection Flying lead (single port models)
Earth stud (rack-mount models)
Specifications
TELECOM LINE PROTECTOR
Grounding System
15
EARTH RESISTANCE TESTING
What you don’t know can hurt you.
3 MAIN PURPOSES OF GROUNDING SYSTEM
1. Overvoltage Protection
Lightning, line surges or unintentional contact with higher voltage lines can cause dangerously
high voltages to the electrical distribution system wires. Grounding provides an alternative
path around the electrical system of your home or workplace minimizes damage from such
occurrences.
2. Voltage Stabilization
There are many sources of electricity. Every transformer can be considered a separate source.
If there were not a common reference point for all these voltage sources it would be
extremely difficult to calculate their relationships to each other. The earth is the most
omnipresent conductive surface, and so it was adopted in the very beginnings of electrical
distribution systems as a nearly universal standard for all electric systems.
3. Current path in order to facilitate the operation of overcurrent devices
This purpose of grounding is the most important one to understand. Grounding system provides
certain level of safety to humans and property in case of equipment damages.
All of these will never work if you don’t have a passing
earth resistance value!
When was the
last time you checked
your Grounding
System?
Specifications
DESCRIPTION PARAMETER
Ambient Temperature -20˚C ~ +55˚C
Weight 5.5 kg
Rectifier Weight 6.9 kg (for 400W high voltage sodium lamp)
Ingress Protection IP66
17
• BUILT-IN TUBE USES DOUBLE FRAME, SPRING-MOUNT
SUPPORTED SHOCKPROOF STRUCTURE.
• PATENTED INTERNAL SHOCK AND IMPACT RESISTANT DESIGN
PROTECTS LIGHT TUBE FROM DAMAGE OR BREAKING.
• HIGH POWER AND COMPACT SIZE, EASY TO INSTALL AND USE.
• BULB INTERIOR CONTAINS COMPRESSED FOAM RUBBER AT
POSITIVE POLES.
• 3MM SILVER PORCELAIN CABLING IMPROVES THE STRENGTH
OF THE SEALING SURFACE.
LF101 Shock-Resistance
Flood Light
Rectifier for 400W high voltage
sodium lamp
DESCRIPTION PARAMETER
Voltage AC200v ~ AC240v
Starting Current 6a
Working Current 4.6a
Power Factor 0.85
Trigger CD-2
DESCRIPTION PARAMETER
Luminous Flux 36,000lm ~ 44,000lm
Average Life 20 ,000h
Luminous Efficiency 100 lm/w
Color Rendering Index Ra25
Specific Power 32kw/m
400W high voltage sodium lamp
tube
Obstruction Light
Specifications
DESCRIPTION PARAMETER
Supply voltage 110-240vac, 20-60vdc(Optional)
Frequency 50hz ~ 60hz
IP Protection IP65
Lamp wattage <5w
Working Steady burning or flashing type
Illumination of each LED 100mcd
Horizontal divergence 360°
LED lifetime ≧100,000 hrs
Ambient temperature -30 ~ +70
Weight 1.25kg
Size 118mm (D) * 275mm(H)
Visual distance >3.5Km (AT=0.85)
18
Model: ABC-7L (Low Intensity)
LIGHTWEIGHT, CORROSION RESISTANT LM6 ALUMINUM BASE. PC
LAMP COVERING FOR EVEN LIGHT DISTRIBUTION, IMPACT
RESISTANCE AND THERMAL STABILITY. THE LAMP HOUSING, WITH
BIRD SPIKE, CONSTRUCTED OF HIGH-TRANSPARENCY GLASS (PC
MATERIAL) AND IS SEALED WITH STRUCTURAL GLUE FOR ADDED
WATER RESISTANCE.
Specifications
DESCRIPTION PARAMETER
Light source 8 ultra-high intensity LEDs
Intensity >10cd (flashing)
Horizontal divergence 360°
Vertical divergence 10°
LED lifetime 100,000 hrs
Flash settings 20 ~ 60 times/min (user-adjustable)
On/off level 70/100 Lux
Solar module type Monocrystalline
Battery capacity 3.6V/10AH (maintenance-free) NIMH
Output 1.8W
Ambient temperature -20~ +80
IP Protection IP65
Automony >200 hrs
Visible distance >3.6Km (atmospheric transparency=0.85)
9
•AVIATION RED LED LIGHTING.
• LM6 DIE-CAST ALUMINUM BASE
• UV RESISTANT POLYCARBONATE LAMP HOUSING.
• BIRD SPIKE. BUILT-IN PHOTOCELL.
• BASE-TO-HOUSING STEEL WIRE PROTECTS AGAINST
FALLING DURING OPERATION AND MAINTENANCE
• BUILT-IN, REPLACEABLE NIMH BATTERY.
• NO RF-RADIATION, EMC COMPLIANT.
• SHOCKPROOF AND CORROSION RESISTANT.
• LOW POWER CONSUMPTION – LOW ENERGY COST.
LT101 Solar Aviation Obstruction Light
Obstruction Light
PRODUCT SELECTION GUIDE
1
APPLICATION P R O D U C T S
ADVANCE (ESE) DISSIPATION
CONVENTIONAL
LIGHTNING
EVENT & SURGE
COUNTER
SURGE DIVERTER
for Main & Branch
Panels
TELECOM LINE
PROTECTOR
COMPUTER
NETWORK
PROTECTOR
CHEMICAL
GROUND ROD
GROUND
ENHANCEMENT
SOLUTION
EQUIPOTENTIAL
PROTECTOR
EARTH
RESISTANCE TEST
LOW INTENSITY
(LED) IP65, 5W
Visual Dist: 3.5km
LOW INTENSITY
(LED) IP65, 5W
Visual Dist: 3.5km
MEDIUM INTENSITY
(LED) IP65, 60W
Visual Dist: 14.5km
CONVENTIONAL
(INCANDESCENT)
LT101 Solar Aviation
Obstruction Light
COAXIAL
LAN/CCTV
PROTECTOR
LIGHTNING
PROTECTION
SYSTEM
SURGE
PROTECTION
DEVICE
GROUNDING
SYSTEM
OBSTRUCTION
LIGHT