Hong Kong Wetland ParkBuilding Technolog 301
Group members:
CHAN Ying Lam, Zara
LAU Sze Mun, Don
LEE Chi Hang, Chris
TANG Pui Shan, Sandy
-
8/3/2019 Wetland Park Stage 1
2/19
Content
Introducon of Wetland Part
Project Data
Concept
Plan
Elevaon and Secon
Secon
Structural systemModular system
Materials
Circulaon system
Lighng system
Drainage system
Conclusion
Reference
-
8/3/2019 Wetland Park Stage 1
3/19
Project Data
Concept
Locaon:
Building Type:
Compleon Year:
Client:
Site Area:
Gross Floor Area (GFA):
Project Manager:
Building Services Engineer:
Quanty Surveyer:
Structural Engineer:Main Contractor:
The concept of the building is to be green with low technology input, which include the following:
1 Green roof with high energy performance
2 Geothermal heat pump hybrid air for condioning system
3 Natural lighng with skylight4 Circulaon ramps instead of lis
5 Collecng water for flushing
6 Using recycled Brick
7 Sustainable mber from idenfied renewable source
8 Concrete having 75% reuse of aggregate
9 Protecng exisng plant
10 Using predominantly nature plant species for planng
Tin Shui Wai, N.T., Hong Kong
Park
2005
Agriculture, Fisheries and Conservaon Department, HKSAR
610,000 sq. m.
10,000 sq. m.
Architectural Services Department, HKSAR
Architectural Services Department, HKSAR
Architectural Services Department, HKSAR
Architectural Services Department, HKSARChevalier (Construcon) Co. Ltd.
About Hong Kong Wetland Park...
Hong Kong Wetland Park is a theme park which was completed in 2005. With the rapid development
of Tin Shui Wai, it is designed to compensate the omit of fish ponds, educang urban cizens the
importance of wetland in our daily living and how to protect the ecology system.
-
8/3/2019 Wetland Park Stage 1
4/19
Site
1:5000
N
-
8/3/2019 Wetland Park Stage 1
5/19
Plan - Ground Floor
1:500 N
-
8/3/2019 Wetland Park Stage 1
6/19
Plan - First Floor
1:500 N
-
8/3/2019 Wetland Park Stage 1
7/19
Plan - Roof
1:500 N
-
8/3/2019 Wetland Park Stage 1
8/19
Elevation and Section
Elevaon 1:500
1:500
1:500
Secon
Secon
-
8/3/2019 Wetland Park Stage 1
9/19
Section
Secon 1:500
1:500
1:5001:500
Secon
Secon Secon
-
8/3/2019 Wetland Park Stage 1
10/19
Section
Secon
Secon 1:500
1:500
-
8/3/2019 Wetland Park Stage 1
11/19
Stctral System
Primary Structure
Secondary Structure
Terary Structure
Secondary Structure
Terary Structure
-
8/3/2019 Wetland Park Stage 1
12/19
Modular System
Structure
-
8/3/2019 Wetland Park Stage 1
13/19
Circulation System
Ramps
Staircase
Circulaon is maily by ramps which minimize the use of li.
-
8/3/2019 Wetland Park Stage 1
14/19
Materials
CONCRETE
VEGETATION
STEEL
WOOD
GLASS
-
8/3/2019 Wetland Park Stage 1
15/19
Why the building is composed of two kind of structural materials (steel & concrete)?
1 For Funcon
2 For accessibility and planng of the roof
For the whole building, only the central part is made of steel, other parts are in concrete structure. This may be related to
the funonal arrangement of the building. The central part is the atrium which welcome all the visitors. Therefore, it is needed
to be bright. Steel structure with glass can achieve this. But for other parts, mostly are the exhibion area, which too much light
will result from glare.
Another reason maybe because the architect wanted to achieve the green roof. As soil and vegetaon are heavy and needed to be
relavely more water-proofed, so concrete is a beer c hoice in this case.
-
8/3/2019 Wetland Park Stage 1
16/19
Conclusion
Reference
From the above analysis, we can see that all the systems that the architect trying to use is ulmately achieving the concept. Also, all the systems are inter-related. Therefore, when we are to choose a system for the building, it is
always not only the system alone. It must be fit to the concept, and it should be well considered with all the other systems.
Architectural Services Department
-
8/3/2019 Wetland Park Stage 1
17/19
Drainage System (Atium)
1
2
3
Rainwater will first run into the horizontal guer (2) through
the inclined surface of the roof (1). As the roof is defined as
certain rows, the rain water in each row will be gathered and
finally drained away by the largest guer placed perpendicularly
to (2). The large guer is 800mm in width.
Rainwater will first run into the horizontal guer (2) through
the inclined surface of the roof (1). As the roof is defined as
certain rows, the rain water in each row will be gathered and
finally drained away by the largest guer placed perpendicularly
to (2). The large guer is 800mm in width.
-
8/3/2019 Wetland Park Stage 1
18/19
Lighting System
As menoned before, the lighng in different zones are different so as to fit the funcon. As the buildings lighng system is mainly deal with natural light,
material is very important in controlling light. The lake in front also contribute to light reflecon.
For the central atrium, the skylight is facing north-east, which can allow the building receive daylight more than sunlight. This can avoid the building being
over-heated and to avoid glare.
Although the parts that made of concrete do not have skylight, it is lighten up by the light through the curtain wall.
Direct light
Reflected light
-
8/3/2019 Wetland Park Stage 1
19/19
From plan and elevaon, we can see that the whole building is made up of module. For the plan, the distance between columns is almost set to 9000mm.
This can ease the construcon, producon of material, as well as minimizing waste