  • 8/8/2019 Wesco Safety in Electricity Distbn

    1/15

    PRESENTATIONPRESENTATION

    ONON

    ENSURING SAFETY INENSURING SAFETY IN

    ELECTRICITY DISTRIBUTIONELECTRICITY DISTRIBUTION

    02 MAY 200902 MAY 2009

    WESCOWESCO

  • 8/8/2019 Wesco Safety in Electricity Distbn

    2/15

    ACCIDENTS AND REASONSACCIDENTS AND REASONSTHEREOFTHEREOF

    UnauthorisedUnauthorised personspersons workingworking onon line/equipmentsline/equipments WorkingWorking withoutwithout obtainingobtaining properproper lineline clearanceclearance WorkingWorking withoutwithout usingusing safetysafety appliancesappliances

    WorkingWorking withoutwithout properproper instructionsinstructions ofof superiorssuperiors WrongWrong feedbackfeedback fromfrom personspersons whowho receivereceive thethe

    lineline clearanceclearance

    Negligence,Negligence, carelessness,carelessness, hastehaste andandoverconfidenceoverconfidence IntoxicationIntoxication whilewhile workingsworkings onon livelive lines,lines, lacklack ofof

    knowledgeknowledge ofof systemsystem networknetwork

  • 8/8/2019 Wesco Safety in Electricity Distbn

    3/15

    ImproperImproper coordinationcoordination LowLow clearanceclearance arisingarising outout ofof roadroad wideningwidening andand

    heighteningheightening

    ExcessiveExcessive sagsag ofof lineline conductorconductor ConstructionConstruction ofof buildingbuilding inin closeclose vicinityvicinity ofof highhigh

    voltagevoltage && lowlow voltagevoltage lineslines

    AttemptAttempt toto stealsteal electricityelectricity (hooking(hooking ))

    LongLong serviceservice connectionconnection lineslines withoutwithout properpropersupportssupports

    IgnoranceIgnorance ofof consumerconsumer andand publicpublic DownDown endend // snapsnap conductorsconductors notnot dealtdealt properlyproperly

    ACCIDENTS AND REASONS THEREOFACCIDENTS AND REASONS THEREOFContd..Contd..

  • 8/8/2019 Wesco Safety in Electricity Distbn

    4/15

    PRECAUTIONS TO BE OBSERVED FORPRECAUTIONS TO BE OBSERVED FORAVOIDING ACCIDENTSAVOIDING ACCIDENTS

    Till LC is received from all sources every line or equipmentshall be treated as live Relay coordination should be ensured with OPTCL & other

    CPPs for clearance of faulty feeder at shortest possible time All consumers irrespective of category should be instructed

    not to connect Generators, Inverters etc. without any expresspermission from the utility company Hang danger board at all strategic places to ensure safety at

    work spot Enforcing safety rules and procedures

    No compromise / second thought on using safety appliances

    State own authorities like PWD, NH, roads and buildings andother agencies should take approprite approval beforeexecuting their projects

    Safety rules and procedures should be displayed atconspicious places, print and electronic media for awarenessof the consumer and general public

  • 8/8/2019 Wesco Safety in Electricity Distbn

    5/15

    Barbed/ wall fencing should be mandatory for theexisting sub-stations and new sub-stations includinggrid sub-stations

    Anti climbing fencing is to be mandatory in allsupports carring live as well as dead HV & LV lines

    Constuction of building beneath / close to thevicinity of HV and LV lines is to prohibited Pamphlets / Guide book should be distributed

    among employees as a ready reckoner.

    Enforcing provisions contained in IE rules and actsshould be stringent Periodical checking and assessment of safety rules

    and procedures should be enforced by appropriateauthority

    PRECAUTIONS TO BE OBSERVED FORPRECAUTIONS TO BE OBSERVED FORAVOIDING ACCIDENTS Contd..AVOIDING ACCIDENTS Contd..

  • 8/8/2019 Wesco Safety in Electricity Distbn

    6/15

    Workmen shall be properly trained Proper dress for workmen Solitary execution of works by workmen should not

    be encouraged.

    For new lines and substations proper clearance anddistance should be maintained

    For temporary earthing should be enhforced before

    taking on the works Procedure of line clearance both at the time ofobtaining the LC and returning the LC should beadhered to.

    Check list before working on line should be prepared

    PRECAUTIONS TO BE OBSERVED FORPRECAUTIONS TO BE OBSERVED FORAVOIDING ACCIDENTS Contd..AVOIDING ACCIDENTS Contd..

  • 8/8/2019 Wesco Safety in Electricity Distbn

    7/15

    SAFETY SLOGANS

    THE FOLLOWING SLOGANS SHOULD BE DISPLAYEDAT EVERY SUB-STATIONS AND GRID SUB-STATIONSAND ALSO SELECTED PLACES ALONG THE LINE:

    No job is so urgent or no service is so

    important that it prevents you taking time todo safely

    Accidents do not happen, they are caused

    Work safe today-Be back tomorrow

    Monkey business has no business in anybusiness

    Learn first aid, you may save several lives

  • 8/8/2019 Wesco Safety in Electricity Distbn

    8/15

    Men who knows Electricity best Respect it Bright people use right tools Safety is everybodys job Employing ELCBs at service connections is

    mandatory

    Do not locateplug points close to floor level-children may play with them

    Do not locate operating rods below vent pipesof DTRs Always be alert . Nobody will be hurt Do not expect your subordinate working atop

    to greet you when you arrive

    SAFETY SLOGANSContd.

  • 8/8/2019 Wesco Safety in Electricity Distbn

    9/15

    SAFETY PRECAUTIONS FOR PROTECTIONAGAINST ELECTRIC SHOCK

    Unauthorised persons shall not attempt replacementof transformer fuses

    Other than utility employees shall not try to replace

    street lights or set right service wires Inform nearest utility office if loose or hanging wiresare noticed

    While drilling bore wells ensure that the casing pipes

    do not touch live wires while they are being lifted up Do not touch low lying or snapped conductor Do not lean against electric poles Do not stand beneath overhead lines while heavy

    winds are blowing

  • 8/8/2019 Wesco Safety in Electricity Distbn

    10/15

    WHAT IS NECESSARY TO IMPROVE SAFETY?

    Attitude to achieve safety Proper use of safety devices Proper training for all

    Proper up-keeping of safety tools Constant improvement upon the safe

    working practices

    Analyse the cause of accidents and preventre-occurance

    Strictly follow the safety rules

  • 8/8/2019 Wesco Safety in Electricity Distbn

    11/15

    RESPONSIBILITY OF EMPLOYEES

    Report : Potential Hazards

    Observe : Safety rules procedures andother code of practice

    Use : with all care of the tools,equipment, safety equipment and

    protective clothing provided by thecompany.

    Participate : In safety training courses whencalled upon to do so

    Make use : Of the knowledge imparted duringthe safety training

    Take : An active and personals intrest inpromoting consiousness for health

    and safety

  • 8/8/2019 Wesco Safety in Electricity Distbn

    12/15

    REPORTED ACCIDENT CASES AS PER

    PUBLICATION IN PRAGATIBADIDATED 17/4/09

    Human Animal Human Animal

    2003-04 27 26 - 12 13

    2004-05 30 28 9 17 18

    2005-06 45 42 6 9 15

    2006-07 45 35 20 18 20

    2007-08 51 39 35 20 33

    Year No of Accident

    Case

    sFatal Accidents

    As per WESCO

    Record

  • 8/8/2019 Wesco Safety in Electricity Distbn

    13/15

    MAINTENANCE OF DISTRIBUTIONSYSTEM AND REDUCTION OF

    ACCIDENTS THEREOFItem Item details Action taken as on 30/3/09 Remarks with programme for

    periodic rectification action

    Inspection of HT/LT lines, cutting of tree

    branches touching the lines

    This is a continuous process. Prunning of tree

    braches are taken up in a planned way toensure minimum load shedding.

    Replacement of damaged stays Whenever such cases are noticed, it is being

    replaced.

    Repairing of tilted poles if any On priority it is being done.

    Restringing of conductors where there

    is inadequate clearance as per I.E. rules

    Restringing of conductors are being taken up

    to increase the clearance. There are also very

    old lines with long span and due sagging the

    clearance becomes inadequate. In order to

    avoid this we are in process to replace such

    conductors with new conductors and to set

    clearance we are putting intermitant poles.

    Maintenance

  • 8/8/2019 Wesco Safety in Electricity Distbn

    14/15

    Item Item details Action taken as on 30/3/09 Remarks with programme for

    periodic rectification action

    Replacement of damaged stays. Whenever such cases are noticed, it is being

    replaced.

    Repairing /Replacement of damaged

    A.B. switches.

    All Damaged AB switches are being

    replaced/repaired. Maintenance of AB

    Switches is now done on regular basis

    Checking/ replacement of jumpers Done Periodically.

    Operation of breakers at 33/11Kv S/S HT Maintenance team has taken up the job

    of maintaining Breakers as well as

    installation of new Breakers at 33/11kv s/s

    and as of now 75% s/s are with Breakers.

    Work still on Progress

    Maintenance of S/S

    (both 11/0.4 KV and

    33/11KV

  • 8/8/2019 Wesco Safety in Electricity Distbn

    15/15

    Item Item details Action taken as on 30/3/09 Remarks with programme for

    periodic rectification action

    Proper up keeping of maintenance of

    registers of 33/11Kv s/s

    It is being done. However to maitain

    uniformity common formats are prepared

    and will be supplied as registers to all s/s byend of May-2009

    A time schedule for periodical

    inspection of distribution lines and S/S

    Every year the JE & SDO make their shedule

    for checking lines & s/s synchrinising with

    the shut down taken by Gridco/OPTCL as well

    as DISCOM, so that there will not be any

    additional shutdowns.

    General