webinar control the forgotten option in retrofitting energy led retrofitting of dwellings 04...

24
Webinar Webinar Control The forgotten option in retrofitting Energy led retrofitting of dwellings 04 september2013 Wouter Borsboom*, Leo Bakker*, Ivo Opstelten (Platform31), Wim Kornaat*, Bas Knoll*, Piet Jacobs* *TNO

Upload: bernardo-bethany

Post on 01-Apr-2015

215 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Webinar Control The forgotten option in retrofitting Energy led retrofitting of dwellings 04 september2013 Wouter Borsboom*, Leo Bakker*, Ivo Opstelten

WebinarWebinar

ControlThe forgotten option in retrofitting

Energy led retrofitting of dwellings

04 september2013

Wouter Borsboom*, Leo Bakker*, Ivo Opstelten (Platform31),

Wim Kornaat*, Bas Knoll*, Piet Jacobs*

*TNO

Page 11: Webinar Control The forgotten option in retrofitting Energy led retrofitting of dwellings 04 september2013 Wouter Borsboom*, Leo Bakker*, Ivo Opstelten

Webinar

Out of a selection of 21 projects in het Netherlands toward nearly zero energy how many houses use control?

11

Ventilation: 3 controlled airflow inlet (passive) and 5 CO2 controlled ventilation systems

Shading: None

Heating/cooling: Most projects have central thermostat

Page 16: Webinar Control The forgotten option in retrofitting Energy led retrofitting of dwellings 04 september2013 Wouter Borsboom*, Leo Bakker*, Ivo Opstelten

Webinar

Improved comfort by shading

16

0

10

20

30

40

50

60

70

80

90

100

16 18 20 22 24 26

% t

ime

per

cen

tag

e b

elo

w g

iven

val

ue

temp (C)

Tliving

Control of external shadingsolar load (W/m2) n/a/ (no shading) > 300 > 200

Tinside (°C) n/a/ (no shading) n/a > 22

Page 17: Webinar Control The forgotten option in retrofitting Energy led retrofitting of dwellings 04 september2013 Wouter Borsboom*, Leo Bakker*, Ivo Opstelten

Webinar

Energy saving by shading

17

0

2000

4000

6000

8000

10000

12000

14000

16000

18000

20000

0

200

400

600

800

1000

1200

1400

1600

1800

2000

hea

t d

eman

d (

MJ/

year

)

coo

l dem

and

(M

J/ye

ar)

Qcool(MJ) Qheat(MJ)

Control of external shading

solar load (W/m2) n/a (no shading) > 300 > 200

Tinside (°C) n/a (no shading) n/a > 22

Page 18: Webinar Control The forgotten option in retrofitting Energy led retrofitting of dwellings 04 september2013 Wouter Borsboom*, Leo Bakker*, Ivo Opstelten

Webinar

Saving potential by zone heating

18

5,5

16,3

10,6

0,0

2,0

4,0

6,0

8,0

10,0

12,0

14,0

16,0

18,0

20,0

local control bedrooms single person working athome

2 working partners

savi

ng

on

hea

tin

g (

%)

Vrijstaand K-peil 45

Page 19: Webinar Control The forgotten option in retrofitting Energy led retrofitting of dwellings 04 september2013 Wouter Borsboom*, Leo Bakker*, Ivo Opstelten

Webinar

How do people use their windows

19

Molensingel 1 - 64

0

50

100

150

200

250

-6 -4 -2 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30

buitentemperatuur [oC]

tota

al a

an

tal o

pe

n r

am

en

dinsdag zondag Linear (dinsdag) Linear (zondag)

Depending on outside temperature

Page 20: Webinar Control The forgotten option in retrofitting Energy led retrofitting of dwellings 04 september2013 Wouter Borsboom*, Leo Bakker*, Ivo Opstelten

Webinar

20

Molensingel 1 - 64

0

50

100

150

200

250

-6 -4 -2 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30

buitentemperatuur [oC]

tota

al a

an

tal o

pe

n r

am

en

dinsdag zondag Linear (dinsdag) Linear (zondag)

Outside Temperature

Nu

mb

er o

f o

pen

win

do

ws

How can we save energy in heating and cooling

Page 21: Webinar Control The forgotten option in retrofitting Energy led retrofitting of dwellings 04 september2013 Wouter Borsboom*, Leo Bakker*, Ivo Opstelten

Webinar

When a warm period / overheating is expected:

Additional ventilation to cool building mass

utilize solar shading to reduce solar gain

Development of a innovative control in the Herb Project