We will blow you away with our fantastic range of
BLOWERS AND FANS
Economy VLL (Very Long Life)Standard Brushless
DIMENSIONS
Single Blowers
Twin Blowers
Grayson Reference: HP3HB0300324S
Single Blower Unit - Standard RangeDimensions:A: 119mmB: 113mmC: 127mm
Grayson Reference: HP3HB0300324S
Single Blower Unit - Standard RangeDimensions:A: 119mmB: 113mmC: 127mm
Grayson Reference: HP3HB0400324S
Single Blower Unit - Standard RangeDimensions:A: 139mmB: 146mmC: 163.9mm
Grayson Reference: HP3HB0400324S
Single Blower Unit - Standard RangeDimensions:A: 139mmB: 146mmC: 163.9mm
Grayson Reference: HP3HB057524AC
Single Blower Unit - Anti-Clockwise StandardDimensions:A: 131mmB: 198mmC: 205mm
Grayson Reference: HP3HB057524C
Single Blower Unit - Clockwise StandardDimensions:A: 131mmB: 198mmC: 205mm
Grayson Reference: HP3HB0500324S
Twin Blower Unit - Standard RangeDimensions:A: 350mmB: 110mmC: 100mm
Grayson Reference: HP3HB0370324s
Twin Blower Unit - Standard RangeDimensions:A: 246mmB: 102mmC: 95mm
Grayson Reference: HP3HB0600324S
Twin Blower Unit - Standard RangeDimensions:A: 335mmB: 146mmC: 163.9mm
Grayson Reference: HP3HB0601124T
Twin Blower Unit - Interal Thermal CutoutDimensions:A: 335mmB: 145mmC: 100mm
Voltage: 24VCFM: 300No. of Speeds: 3
Voltage: 24VCFM: 300No. of Speeds: 3
Voltage: 24VCFM: 400No. of Speeds: 3
Voltage: 24VCFM: 400No. of Speeds: 3
Voltage: 24VCFM: 575No. of Speeds: 3
Voltage: 24VCFM: 300No. of Speeds: 3
Use the diagram to the left as a reference to measure the dimensions of your blower. This will help you determine
which blower is suitable for your vehicle.
A: Length B: Width C: Height
The colour key below should assist you in identifying what range each blower belongs to:
Economy VLL (Very Long Life)Standard Brushless
WE HAVE CREATED A UNIQUE HARNESS TO CONTAIN THE BRUSHLESS
TECHNOLOGY
See this product and more on our website graysonts.com
OUR NEW BRUSHLESS BLOWER
Voltage: 24VCFM: 500No. of Speeds: 3
Voltage: 24VCFM: 370No. of Speeds: 3
Voltage: 24VCFM: 600No. of Speeds: 3
Voltage: 24VCFM: 600No. of Speeds: 1
Brushless
Twin Blowers
Grayson Reference: HP3HB0602424V
Twin Blower Unit - Very Long LifeDimensions:A: 340mmB: 148mmC: 168mm
Grayson Reference: HP3HB0610324S
Twin Blower Unit - Standard RangeDimensions:A: 334mmB: 103mmC: 113mm
Grayson Reference: HP3HB0603324S
Twin Blower Unit - Economy RangeDimensions:A: 337mmB: 151mmC: 168mm
Grayson Reference: HP3HB0730324S
Twin Blower Unit - Standard RangeDimensions:A: 350mmB: 133mmC: 156mm
Grayson Reference: HP3HB0810324S
Single Blower Unit - Economy RangeDimensions:A: 302.5mmB: 130mmC: 128mm
Grayson Reference: HP3HB0850324S
Single Blower Unit - Standard RangeDimensions:A: 351mmB: 139.8mmC: 167.5mm
Grayson Reference: HP3HB0851424V
Single Blower Unit - Very Long LifeDimensions:A: 351mmB: 140mmC: 156mm
Grayson Reference: HP3HB1000324S
Single Blower Unit - Economy RangeDimensions:A: 353mmB: 144mmC: 175mm
Grayson Reference: HP3HB0800124S
Twin Blower Unit - Standard/No ResistorDimensions:A: 310mmB: 113.1mmC: 127.5mm
Grayson Reference: HP3HB0800324S
Twin Blower Unit - Standard RangeDimensions:A: 310mmB: 113.1mmC: 127.5mm
Grayson Reference: HP3HB0801324S
Twin Blower Unit - Standard RangeDimensions:A: 310mmB: 113.5mmC: 128mm
Grayson Reference: HP3HB0802324S
Twin Blower Unit - Standard RangeDimensions:A: 310mmB: 113.5mmC: 128mm
Grayson Reference: HP3HB1010324S
Twin Blower Unit - Standard RangeDimensions:A: 428mmB: 152mmC: 115mm
Grayson Reference: HP3HB1001324S
Single Blower Unit - Standard RangeDimensions:A: 351mmB: 139.8mmC: 167.5mm
Grayson Reference: HP3HB1050124S
Twin Blower Unit - Standard RangeDimensions:A: 351mmB: 167.5mmC: 139.8mm
Grayson Reference: HP3HB1050324S
Twin Blower Unit - Standard RangeDimensions:A: 351mmB: 140mmC: 135mm
Voltage: 24VCFM: 800No. of Speeds: 3
Voltage: 24VCFM: 850No. of Speeds: 3
Voltage: 24VCFM: 850No. of Speeds: 4
Voltage: 24VCFM: 1000No. of Speeds: 3
Voltage: 24VCFM: 800No. of Speeds: 1
Voltage: 24VCFM: 800No. of Speeds: 3
Voltage: 24VCFM: 800No. of Speeds: 3
Voltage: 24VCFM: 850No. of Speeds: 3
Voltage: 24VCFM: 1000No. of Speeds: 3
Voltage: 24VCFM: 1000No. of Speeds: 3
Voltage: 24VCFM: 1050No. of Speeds: 1
Voltage: 24VCFM: 1050No. of Speeds: 3
OUR FANTASTIC RANGEOF BLOWERS AND FANS
Voltage: 24VCFM: 600No. of Speeds: 1
Voltage: 24VCFM: 600No. of Speeds: 3
Voltage: 24VCFM: 600No. of Speeds: 3
Voltage: 24VCFM: 730No. of Speeds: 3
Twin Blowers
Grayson Reference: HP3HB1300124T
Twin Blower Unit - Standard RangeDimensions:A: 350mmB: 140mmC: 135mm
Grayson Reference: HP3HB1300124T
Twin Blower Unit - Standard RangeDimensions:A: 350mmB: 140mmC: 135mm
Grayson Reference: HP3HB1300124T
Twin Blower Unit - Standard RangeDimensions:A: 350mmB: 140mmC: 135mm
Grayson Reference: HP3HB1051424V
Twin Blower Unit - Very Long LifeDimensions:A: 351mmB: 140mmC: 140mm
Grayson Reference: HP3HB1150124S
Twin Blower Unit - Standard/No ResistorDimensions:A: 351mmB: 139.8mmC: 167.5mm
Grayson Reference: HP3HB1150124S
Twin Blower Unit - Standard RangeDimensions:A: 351mmB: 139.8mmC: 167.5mm
Grayson Reference: HP3HB1200324S
Twin Blower Unit - Sub Plate SaloonDimensions:A: 376mmB: 180mmC: 174mm
Grayson Reference: HP3HB1202324V
Twin Blower Unit - Very Long LifeDimensions:A: 548mmB: 170mmC: 188mm
Grayson Reference: HP3HB1202324V
Twin Blower Unit - Very Long LifeDimensions:A: 548mmB: 170mmC: 188mm
Grayson Reference: HP3HB1202324V
Twin Blower Unit - Very Long LifeDimensions:A: 548mmB: 170mmC: 188mm
Grayson Reference: HP3HB1250124S
Twin Blower Unit - Standard RangeDimensions:A: 351mmB: 154.3mmC: 183.5mm
Grayson Reference: HP3HB1400124L
Twin Blower Unit - Brushless RangeDimensions:A: 350mmB: 140mmC: 135mm
Grayson Reference: HP3HB1401124L
Twin Blower Unit - Brushless RangeDimensions:A: 351mmB: 141mmC: 162mm
Voltage: 24VCFM: 1300No. of Speeds: 1
Voltage: 24VCFM: 1300No. of Speeds: 1
Voltage: 24VCFM: 1300No. of Speeds: 1
Voltage: 24VCFM: 1050No. of Speeds: 4
Voltage: 24VCFM: 1150No. of Speeds: 1
Voltage: 24VCFM: 1150No. of Speeds: 3
Voltage: 24VCFM: 1200No. of Speeds: 3
Voltage: 24VCFM: 1200No. of Speeds: 3
Voltage: 24VCFM: 1200No. of Speeds: 3
Voltage: 24VCFM: 1200No. of Speeds: 3
Voltage: 24VCFM: 1250No. of Speeds: 1
Voltage: 24VCFM: 1400No. of Speeds: 1
Voltage: 24VCFM: 1400No. of Speeds: 1
Visit www.graysonts.comfor more products
Can’t find the productyou’re looking for?
Come to us directly andlet us help you find it.
Excellence inproduct quality
and service
Grayson Reference:
HP3HF6080
Heater Fan, 166mm, Rimmed (Red) D-Shape - use with Motor HP3HM8100
Grayson Reference: HP-2809-000
Condenser Fan
Grayson Reference: HP-2498-001
Plastic Fan
Grayson Reference: HP-2498-002
Plastic Fan
Grayson Reference: HP-2608-000
Condenser Fan
Grayson Reference: HP3HF332A
Heater Fan, 160mm,Not Rimmed
Grayson Reference: HP3HB1250124S
Twin Blower Unit - Standard RangeDimensions:A: 351mmB: 154.3mmC: 183.5mm
Grayson Reference: HP-2811-000
Fan Voltage: 24VDiameter: 190mm Blowing/Pushing
Grayson Reference: HP-2812-000
Axial Motor FanVoltage: 24VDiameter: 96mmSucking/Pulling
Grayson Reference: HP3HF005/100
FanVoltage: 24VDiameter: 92.5mm Blowing/Pushing
Grayson Reference: MP-1020-026
FanVoltage: 24VDiameter: 305mm Blowing/Pushing
Grayson Reference: MP-1020-034
FanVoltage: 24VDiameter: 305mm Blowing/Pushing
Grayson Reference: MP-1020-059
FanVoltage: 24VDiameter: 305mm Blowing/Pushing
Grayson Reference: HP3HF005
Heater Fan Voltage: 24VDiameter: 140mm Sucking/Pulling
Grayson Reference: HP-2814-000
Condenser Fan
Voltage: 24VDiameter: 358.5mmBlowing/Pushing
Grayson Reference: HP-2815-000
Condenser Fan
Voltage: 24VDiameter: 305mm Sucking/Pulling
Grayson Reference: MP-1020-025
Condenser Fan
Voltage: 24VDiameter: 280mm Sucking/Pulling
Grayson Reference: HP-2810-000
Condenser Fan
Voltage: 24VDiameter: 280mm Sucking/Pulling
Grayson Reference: MP-1013-017
Condenser Fan
Voltage: 24VDiameter: 280mm Blowing/Pushing
Grayson Reference: VA11-BP12/C-29S-24V
Condenser Fan
Voltage: 24VDiameter: 280mmBlowing/Pushing
Grayson Reference: HP-2813-000
Condenser Fan
Voltage: 24VDiameter: 305mm Blowing/Pushing
Axial Motor Fans & Fan Blades
See back for our Tips
CREATING THE FUTURE OF THERMAL MANAGEMENTINTERNATIONAL SUPPLIERS OF COOLING, HEATING AND AIR CONDITIONING PRODUCTS.
GRAYSON THERMAL SYSTEMS UK
Wharfdale House257 Wharfdale RoadTyseley, Birmingham B11 2DP
t +44 (0)121 700 5600 f +44 (0)121 700 5601e [email protected] w graysonts.com
GRAYSON THERMAL SYSTEMS CORP USA
980 Hurricane RoadFranklin, IndianaIN 46131
t +1 (317) 739-3290 f +1 (317) 739-3281 e [email protected] graysonts-na.com
We are here to help
TIP 1 Making sure you have selected the correct blower is vital to the heating performance of your vehicle. Many blowers look the same but perform completely different in terms of airflow and back pressure. You must make sure the cost of the unit does not persuade you to buy the wrong blower.
TIP 2 Air side blockages also reduce the performance of your blower. When there is a blockage in your heater, the air that should be circulating through your blower is non existent. However, the blower will be performing at the same output as it would be with the airflow present, but without the air to cool the motor/bearings the unit will overheat, resulting in the failure of your blower.
TIP 3 It has also been shown that poorly fitted blowers reduce the overall efficiency of the system. As air leaves the vehicle via gaps between the mounting plate & the blower, this results in a loss of capacity and performance.
TIP 4 Finally, if your blower has a damaged scroll or wheel, the performance of the blower will again be reduced. The airflow will be affected along with the balance of the blower. When the balance of the blower wheels is affected, it can result in the damage of the motor and therefore ruin the blower.