We optimize performance.

We brave the weather.

2

TEKOPACKduo and TEKOPACKduo plus.

• Future-proof & eco-friendly • Conforms to F-gas regulations – use of R 134a, R 407F,

R 449A• Variable setup & fast installation• Reasonably priced• Short delivery times & good stock availability

Capacity ranges.

(Q0 at -10 °C / +45 °C)

• R 134a: 1,60...22,54 kW• R 407F: 2,75...35,88 kW• R 449A: 2,69...35,04 kW

Very easily controlled.

• Equipped with WURM Frigoentry DCC-XP V6.0• Multi compressor system control with integrated conden-

sation pressure regulation• Latest software release with integrated XLR2.0 capacity

control

Application areas.

Filling station shops, food shops, bakeries, butchers, restau-rants and many more. The TEKOPACK units suit also very well as retrofit systems.

TEKOPACKduo. Now available in two versions.

1. TEKOPACKduo. With Bitzer compressors – NEW also with 2 cylinder models.2. TEKOPACKduo plus. With Frascold compressors, including capacity control XLR2.0

Capacity control precisely adjustable. XLR2.0 makes it possible.

The capacity can be regulated in 8 steps from 12,5 % to 100 % (4 cylinders) respectively from 25 % to 100 % (2 cylin-ders). This makes the capacity range bigger than any other form of capacity adjustment known on the market. The inno-vative system offers an optimum performance and efficiency. A stable suction pressure and reduced switching cycles provide high reliability. An optimal solution.

The four-step capacity control for 4-cylinder compressors in combination with the two-compressor-rack unit makes a 8-step control from 12,5 – 25 – 37,5 – 50 – 62,5 – 75 – 87,5 – 100 % possible.

The capacity control for 2-cylinder compressors combined with the two-compressor-rack unit enables capacity control in 4 steps: 25 – 50 – 75 – 100 %.

Double your savings. Energy and investment costs.

• Less investment costs• Reduced oil carry-over• No need of shielded cables• No need of parametrization• High availability

Durability.

• Even use of all capacity controlled pistons• Smooth-running – as in full load operation

3

OUTDOORduo und OUTDOORplus.

You don’t have a machine room available or a lack of space?Then go for the OUTDOOR version.It combines machine and condenser technologies in a space-sa-ving housing – just Plug & Play.

Capacity ranges.

(t0 -10 °C / tLE +32 °C)

• R 134a: 7,17...24,14 kW• R 407F: 12,42...37,24 kW

Housing.

• Compact, “L” shaped construction• Aluminium fins with special „air intake“ profile, designed

for the use of new refrigerants. • Fin spacing 2.1 mm

OUTDOOR version for outdoor installation.

1. OUTDOORduo. Models with Bitzer.1. OUTDOORduo plus. Models with Frascold.

4

6...36kW

Scope of delivery. Rack unit, completely mounted and tubed.

• Frascold or Bitzer-reciprocating compressors (including electronic motor protection device and crankcase heater)• Frascold compressors: Capacity control XLR2.0.

- Type D (2-cylinder compressors) – mounted on each compressor for the purpose of base load switch-over - Type Q (4-cylinder compressors) –fi rst compressor equipped with a XLR2.0 head and a standard CC head

• Bitzer compressors: Capacity control LR. - Type 4FES-4CES – LR mounted on each compressor. 4 steps. - 2-cylinder compressors – no capacity control. 2 steps.• Frascold compressors: Rigid oil equalisation line including oil compensation adapter• Safety devices including adjustable LP limiter, HP limiter fi xed settings each compressor, LP pressure transducers• Refrigerant receiver of 15 or 30 litres• Liquid set (fi lter drier, sight glass, ball shutoff valve)• Insulation on suction side• Ball shutoff valves (discharge line, condensate line)• Antivibration pads

Optional:• Rack unit fi tted with an integrated wired switch cabinet, equipped with:

WURM rack unit controller DCC-XP, main switch 25, 32 or 63 ampere, common fault, control transformer, motor protection switch, load output of condenser 230/400V, up to max. 16A.

• Oil separator including oil equalisation• Additional fan for low temperature applications

5

Model Cooling capacity Switch- Receiver Max. DimensionsTEKOPACKduo t0 -10 °C / tC +45 °C cabinet size weight Length Depth Height

R 134a R 407F R 449AkW kW kW A Liters approx. kg mm mm mm

TPduo – 2EES-2Y 6,62 11,12 10,76 2515

265 (15 L*)

310 (30 L*)

1.460 (15 L*)

1.490 (30 L*)615 696

TPduo – 2DES-2Y 7,96 13,34 12,90 25TPduo – 2CES-3Y 9,90 16,52 15,96 32TPduo – 4FES-3Y 10,16 18,10 17,48 32 15 / 30*TPduo – 4EES-4Y 13,56 22,66 21,90 32

30TPduo – 4DES-5Y 15,64 26,62 25,74 63TPduo – 4CES-6Y 19,46 33,00 31,88 63

TEKOPACKduo. Bitzer compressors.

TEKOPACKduo plus. Frascold compressors. Capacity control XLR 2.0.

Performance data 50 Hz refer to a suction gas temperature of 20 °C, without liquid subcooling (according to EN 12900)* The receiver size depends on the refrigerant used (R 134a / R 407F / R 449A). Extension of the receiver size is possible as an option. If a 45-litres-receiver is required, it is possible to mount a TSSX45 model (horizontal version).

Model Cooling capacity Switch- Receiver Max. DimensionsTEKOPACKduo plus t0 -10 °C / tC +45 °C cabinet size weight Length Depth Height

R 134a R 407F R449AkW kW kW A Liters approx. kg mm mm mm

TPduo plus – D2.11.1Y 6,40 10,94 10,76 25

15 2651.460

(15 L*)

615 696

TPduo plus – D2.13.1Y 7,72 13,10 12,48 25TPduo plus – D3.15.1Y 8,76 15,18 14,87 32TPduo plus – D3.18.1Y 10,80 18,02 17,32 32TPduo plus – D4.18.1Y 11,00 17,88 17,67 32TPduo plus – Q4.20.1E 12,36 – – 25TPduo plus – Q4.20.1Y 12,08 19,04 18,20 32TPduo plus – Q4.24.1E 14,02 – – 25TPduo plus – Q4.24.1Y 13,14 23,68 21,52 32TPduo plus – Q5.28.1E 16,08 – – 32

30 3101.490

(30 L*)

TPduo plus – Q5.28.1Y 15,78 27,72 26,14 63TPduo plus – Q5.33.1E 19,24 – – 32TPduo plus – Q5.33.1Y 18,72 33,02 31,22 63TPduo plus – Q5.36.1Y 22,38 – – 32TPduo plus – Q7.36.1Y 22,54 35,88 35,04 63

6

Model Cooling capacity Sound Switch- Receiver Max. weight DimensionsOUTDOORduo t0 -10 °C / tLE +32 °C pressure total cabinet size R 134a R 407F Length Depth Max. Height

R 134a R 407F in 10 mkW kW dB(A) A Liters approx. kg approx. kg mm mm mm

ODduo – 2EES-2Y 7,39 12,69 47 2515

560594

2.152 1.035 1.500

ODduo – 2DES-2Y 8,71 14,98 47 25ODduo – 2CES-3Y 10,55 18,16 48 32ODduo – 4FES-3Y 10,87 19,77 49 32 15 / 30*

649ODduo – 4EES-4Y 15,11 23,93 51 32 30 649ODduo – 4DES-5Y 17,48 28,10 53 63

45 680 680ODduo – 4CES-6Y 21,25 33,66 53 63

Model Cooling capacity Sound Switch- Receiver Max. weight DimensionsOutdoorplus t0 -10 °C / tLE +32 °C pressure total cabinet size R 134a R 407F Length Depth Max. Height

R 134a R 407F in 10 mkW kW dB(A) A Liters approx. kg approx. kg mm mm mm

ODduo plus – D2.11.1Y 7,17 12,42 47 25

15560 594

2.152 1.035 1.500

ODduo plus – D2.13.1Y 8,48 14,69 48 25ODduo plus – D3.15.1Y 9,57 16,82 47 32ODduo plus – D3.18.1Y 11,35 19,51 49 32ODduo plus – D4.18.1Y 11,65 19,41 49 32

30

ODduo plus – Q4.20.1E 14,19 -- 49 25

649649

ODduo plus – Q4.20.1Y 13,52 20,63 49 32ODduo plus – Q4.24.1E 15,73 -- 49 25ODduo plus – Q4.24.1Y 14,78 24,90 49 32ODduo plus – Q5.28.1E 17,74 -- 51 32

680

ODduo plus – Q5.28.1Y 17,35 29,13 51 63ODduo plus – Q5.33.1E 21,06 -- 52 32

45 680ODduo plus – Q5.33.1Y 20,39 34,70 52 63ODduo plus – Q5.36.1Y 24,11 -- 50 32ODduo plus – Q7.36.1Y 24,14 37,24 50 63

Performance data 50 Hz refer to a suction gas temperature of 20 °C, without liquid subcooling (according to EN 12900)* The receiver size depends on the refrigerant used (R 134a / R 407F).

OUTDOORduo. Bitzer compressors.

OUTDOORduo plus. Frascold compressors. Capacity control XLR 2.0.

7

7...37kW

Scope of delivery.Rack unit, completely mounted, tubed and integrated in condenser housing.

• The rack unit’s equipment corresponds to the TEKOPACKduo and TEKOPACKduo plus standard scope of delivery. • Refrigerant receiver of 15, 30 or 45 litres• Vibration eliminators (discharge line, suction line, liquid line)• Maintenance-friendly housing with integrated condenser:

- 2 axial fans Ø 630 or 710 mm (depending on the model) - single-phase fan motor (230V/1pH/50-60Hz), with integrated start capacitor , insulation class B, internal temperature limiter

• Rack unit fi tted with an integrated wired switch cabinet (mounted on the inside of the housing door), equipped with: WURM rack unit controller DCC-XP, main switch 25, 32 or 63 ampere, common fault, control transformer, motor protection switch, condenser regulator with speed controller, Protection class IP 54.

Options.• Bigger receiver• Additional fan (please observe manufacturer’s criteria for use with diff erent refrigerants)• Protection of switch cabinet for extreme conditions (summer operation – ventilation, winter operation – heating)• Condensing pressure control • EC fans for condenser

TEKO Gesellschaft für Kältetechnik mbHCarl-Benz-Straße 1

63674 AltenstadtGermany

Tel.: +49 (0) 60 47 / 96 30- 0Fax: +49 (0) 60 47 / 96 30-100

[email protected]