we have always protected ourselves …
DESCRIPTION
WE HAVE ALWAYS PROTECTED OURSELVES …. Threats of Weapons of Mass Destruction are out there - are you protected?. PROTECT OR EVACUATE. You can increase your mobility - but many have to stand still - provide them with proper protection. DON’T FORGET PROTECTION. Shelter Technology. - PowerPoint PPT PresentationTRANSCRIPT
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
WE HAVE ALWAYS PROTECTED OURSELVES …WE HAVE ALWAYS PROTECTED OURSELVES …
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
PROTECT OR EVACUATEPROTECT OR EVACUATE
Threats of Weapons of Mass Destruction are out there - Threats of Weapons of Mass Destruction are out there - are you protected?are you protected?
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
DON’T FORGET PROTECTIONDON’T FORGET PROTECTION
•You can increase You can increase your mobility - but your mobility - but many have to stand many have to stand still still
- provide them with - provide them with proper protectionproper protection
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Shelter TechnologyShelter Technology
TemetTemet is the world-leading is the world-leading supplier of expert supplier of expert technology for shelters and technology for shelters and protective constructions. protective constructions.
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Protected shelter Protected shelter spacespace- blast protectedblast protected- gastightgastight
- shock protected- shock protected
- cleaned air- cleaned air
- overpressured- overpressured
Shelter technology applicationsShelter technology applications
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Shelter technology applicationsShelter technology applications
Protected shelter areaProtected shelter area
Blast valves at both Blast valves at both ends of the air tunnelends of the air tunnel
HVAC plant room housing HVAC plant room housing NBC Filtration and CWA NBC Filtration and CWA detection systemsdetection systems
Special wall sleeves for Special wall sleeves for penetrations of plumbing, penetrations of plumbing, piping and cables through piping and cables through blast resistant and gas tight blast resistant and gas tight wallswalls
Gas and air tight and Blast resistant doors at entrancesGas and air tight and Blast resistant doors at entrances
Shock isolation of Shock isolation of mechanical and mechanical and electrical installationselectrical installations
Gas tight shut-off valves at Gas tight shut-off valves at air ducts along gas tight air ducts along gas tight perimeterperimeter
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Product RangeProduct Range• Protective DoorsProtective Doors
– Blast Resistant Doors and Blast Resistant Doors and HatchesHatches
– Gastight Door and HatchesGastight Door and Hatches
• HVAC Protection productsHVAC Protection products– Blast ValvesBlast Valves– Gastight Closing ValvesGastight Closing Valves– Other valvesOther valves– NBC – Filters for buildingsNBC – Filters for buildings– NBC – Filtration SystemsNBC – Filtration Systems– Emergency Ventilation UnitsEmergency Ventilation Units
• Other productsOther products– NBC – Filters for mobile NBC – Filters for mobile
applicationsapplications– NBC – TentsNBC – Tents– Diesel Engine Blast ValvesDiesel Engine Blast Valves– Ground Shock IsolatorsGround Shock Isolators
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Protective DoorsProtective Doors
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
• TemetTemet Blast resistant doors, gas and Blast resistant doors, gas and airtight doors:airtight doors:
• Gastight Series:Gastight Series: Doors, Double Doors, Double Doors, Sliding Doors and HatchesDoors, Sliding Doors and Hatches
• Blast Series 2 bar:Blast Series 2 bar: Doors, Double Doors, Double Doors, Sliding Doors and HatchesDoors, Sliding Doors and Hatches
• Blast Series 6 to 9 bar:Blast Series 6 to 9 bar: Doors, Doors, Double Doors, Sliding Doors, Double Doors, Sliding Doors, Concrete Arch DoorsConcrete Arch Doors
• Blast Series 18 bar:Blast Series 18 bar: Doors, Double Doors, Double Doors, Sliding Doors, Concrete Arc Doors, Sliding Doors, Concrete Arc Doors Doors
• Custom Made Doors according Custom Made Doors according Client’s SpecificationsClient’s Specifications
Protective DoorsProtective Doors
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Protective DoorsProtective Doors
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Protective DoorsProtective Doors
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Protective DoorsProtective Doors
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Protective DoorsProtective Doors
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Protective DoorsProtective Doors
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Protective DoorsProtective Doors
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Protective DoorsProtective Doors
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Protective DoorsProtective Doors
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Testing and approvals of Testing and approvals of blast resistant doorsblast resistant doors
Due to the large size of the Due to the large size of the object, blast testing of the object, blast testing of the blast resistant doors is blast resistant doors is usually difficult and very usually difficult and very expensive. Therefore, the expensive. Therefore, the design is usually based on design is usually based on either static or dynamic either static or dynamic analysis, where the design analysis, where the design load application is given in load application is given in static pressure or pressure-static pressure or pressure-time load.time load.
New 3D-design and analysis New 3D-design and analysis tools are routinely used in tools are routinely used in blast resistant door design. blast resistant door design.
Protective DoorsProtective Doors
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
• The reinforcement of blast protective bulkheads and walls shall be The reinforcement of blast protective bulkheads and walls shall be made properly to ensure protection against blast effects. Temet can made properly to ensure protection against blast effects. Temet can provide the bulkhead reinforcement design.provide the bulkhead reinforcement design.
• The proper installation and alignment of protective doors shall always The proper installation and alignment of protective doors shall always be checked before casting. Temet can provide the installation be checked before casting. Temet can provide the installation supervision services.supervision services.
Protective DoorsProtective Doors
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Protective DoorsProtective Doors
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Protective DoorsProtective Doors
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
HVAC protectionHVAC protection
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Blast protection and gastight Blast protection and gastight closing of HVAC systemsclosing of HVAC systems
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Valve productsValve products
TemetTemet Blast Valves: Blast Valves: applications in:applications in:• blast barriers of air tunnelsblast barriers of air tunnels• passage way ventilationpassage way ventilation• diesel generator exhaust diesel generator exhaust
systemsystem
Temet Gastight Closing Valves:Temet Gastight Closing Valves: applications in:applications in:• air ducts along the gas air ducts along the gas
tight perimeter for tight perimeter for separation of toxic free and separation of toxic free and contaminated areas and for contaminated areas and for regulation of the internal regulation of the internal overpressureoverpressure
Temet Other Valves:Temet Other Valves:
• Overpressure valves for Overpressure valves for regulating the internal regulating the internal overpressureoverpressure
• Combined Combined blast/overpressure valvesblast/overpressure valves
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Blast Valves PSV-seriesBlast Valves PSV-series
Blast Protection up to 60 bar short Blast Protection up to 60 bar short duration blastduration blast
Maximum air flow:Maximum air flow:
• PSV-350 7200 mPSV-350 7200 m33/h (4240 cfm)/h (4240 cfm)• PSV-250 4000 mPSV-250 4000 m33/h (2350 cfm)/h (2350 cfm)• PSV-150 2500 mPSV-150 2500 m33/h (1470 cfm)/h (1470 cfm)
- Ease of installation in the wall - Ease of installation in the wall and between ductsand between ducts- Saves wall space - Saves wall space
Normal Normal ventilation ventilation positionposition
Blast pressure from Blast pressure from the outsidethe outsideValve closesValve closes
Negative pressure from Negative pressure from the outsidethe outsideValve closesValve closes
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Blast Valves PSV-seriesBlast Valves PSV-series
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Blast Valves PSV-seriesBlast Valves PSV-series
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
• PSV-series Blast PSV-series Blast Valves provide space Valves provide space saving bulkhead saving bulkhead solution. solution.
• The installation of the The installation of the valves is very simple.valves is very simple.
• The valve can be The valve can be provided with flanges provided with flanges at both ends for duct at both ends for duct connection. connection.
• The PSV-series blast The PSV-series blast valves combine high valves combine high protection level with protection level with high air flow capacity.high air flow capacity.
Alternative Alternative installationsinstallations
Blast Valves PSV-seriesBlast Valves PSV-series
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Blast Valves PV-KKBlast Valves PV-KK
Blast Protection up to 15 Blast Protection up to 15 bar short duration blastbar short duration blast
• Typical Air flow in one Typical Air flow in one block 720 mblock 720 m33/h (424 cfm)/h (424 cfm)
• Can be built into I-beam Can be built into I-beam wallshousing, hundreds wallshousing, hundreds of valve blocksof valve blocks
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Operation of PV-KK valvesOperation of PV-KK valves
Normal Normal ventilation ventilation positionposition
Blast pressure from Blast pressure from the outsidethe outsideValve closesValve closes
Negative pressure from Negative pressure from the outsidethe outsideValve closesValve closes
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
PV-KK Installation VersionsPV-KK Installation Versions
PV-KK PV-KK to be cast in to be cast in concrete wall. concrete wall.
PV-KK-SM for surface PV-KK-SM for surface mounting by anchor mounting by anchor bolts to concrete wall bolts to concrete wall or by welding or or by welding or bolting to steel wallbolting to steel wall
PV-KK-W to be PV-KK-W to be installed in an installed in an opening by welding opening by welding to subframe or steel to subframe or steel structure.structure.
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Gastight Closing Valves KS-seriesGastight Closing Valves KS-series
• Gastight valves with nominal Gastight valves with nominal diameter from 100 - 800 mmdiameter from 100 - 800 mm
• Leakage does not exceed (KS-Leakage does not exceed (KS-350) 0.001 l/s at pressure 350) 0.001 l/s at pressure differential of 1000 Pa. differential of 1000 Pa.
• Valves can be provided withValves can be provided with– electric,electric,– pneumatic or electro-mechanic pneumatic or electro-mechanic – fail-safe actuators. fail-safe actuators.
• Wide range of applications in Wide range of applications in protected buildings, protected buildings, petrochemical and nuclear petrochemical and nuclear power industrypower industry
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Overpressure blast valve YV-1Overpressure blast valve YV-1
• Blast Protection up to 3 bar Blast Protection up to 3 bar short duration blastshort duration blast
• Hand-wheel for adjusting Hand-wheel for adjusting overpressure in shelteroverpressure in shelter
• Gastight when closed manuallyGastight when closed manually
Normal ventilation
position
Blast pressure from the outside
damper closes
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
NBC Protection in SheltersNBC Protection in Shelters
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
TemetTemet NBC-Filters, NBC- NBC-Filters, NBC-filtration systems and filtration systems and Emergency Ventilation Units:Emergency Ventilation Units:Applications in:Applications in:
– Filtration of Nuclear Fallout, Filtration of Nuclear Fallout, Biological and Chemical Biological and Chemical Warfare Agents and Toxic Warfare Agents and Toxic Industrial ChemicalsIndustrial Chemicals
EnvironicsEnvironics Chemical Chemical Warfare Agent Detection and Warfare Agent Detection and Analyzing Systems:Analyzing Systems:Applications in:Applications in:
– Detection of CWA in intake Detection of CWA in intake air and downstream of filtersair and downstream of filters– Monitoring of contaminationMonitoring of contamination
NBC Protection in SheltersNBC Protection in Shelters
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
NBC Filtrations systemsNBC Filtrations systems
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
NBC FiltersNBC Filters
• Temet ES-600 NBC-filterTemet ES-600 NBC-filter– Filtration capacity 600 MFiltration capacity 600 M33/H /H
(353 cfm) at nominal pressure (353 cfm) at nominal pressure drop ~ 800Padrop ~ 800Pa
– Blast resistance of the filter 2 barBlast resistance of the filter 2 bar– Mechanical resistance 20g.Mechanical resistance 20g.
• Tested and Approved by: Tested and Approved by: – Technical Research Centre of Technical Research Centre of
Finland/VTT Building and Finland/VTT Building and Transport,Transport,
– Defence Forces Research CentreDefence Forces Research Centre
• New carbon available for wide New carbon available for wide spectrum removal of CWA, TIC’s spectrum removal of CWA, TIC’s and radioactive gasesand radioactive gases
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
• Temet ES-1250 NBC-filterTemet ES-1250 NBC-filter– Filtration capability 1250 mFiltration capability 1250 m33/h /h
(735 cfm) at nominal pressure (735 cfm) at nominal pressure >> 800Pa800Pa
– Blast resistance of the filter 2 barBlast resistance of the filter 2 bar– Mechanical resistance 20g.Mechanical resistance 20g.
• Tested and Approved by: Tested and Approved by: – Technical Research Centre of Technical Research Centre of
Finland/VTT Building and Finland/VTT Building and TransportTransport
– Defence Forces Research CentreDefence Forces Research Centre• NBC filter with the highest air NBC filter with the highest air
flow capacity available.flow capacity available.
NBC FiltersNBC Filters
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Emergency Ventilation UnitsEmergency Ventilation Units
• Temet VIL Emergency Units Temet VIL Emergency Units are designed for small and are designed for small and medium sized shelters.medium sized shelters.
• All units has in-build pre-All units has in-build pre-filters and optionally can be filters and optionally can be provided with intake air pre-provided with intake air pre-heater.heater.
• VIL-units occupies less VIL-units occupies less space than any other similar space than any other similar equipment.equipment.
• Each unit are provided with Each unit are provided with air flow meter.air flow meter.
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
NBC Filtration SystemsNBC Filtration Systems
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
TypeType MM33/H/H
ESL-1200ESL-1200 12001200
ESL-1800ESL-1800 18001800
ESL-2400ESL-2400 24002400
ESL-3000ESL-3000 30003000
ESL-3000-2ESL-3000-2 60006000
ESL-3000-3ESL-3000-3 90009000
ESL-3000-4ESL-3000-4 1200012000
ESL-3000-5ESL-3000-5 1500015000
ESL-1250ESL-1250 12501250
ESL-2500ESL-2500 25002500
ESL-3750ESL-3750 37503750
ESL-5000ESL-5000 50005000
ESL-5000-2ESL-5000-2 1000010000
ESL-5000-3ESL-5000-3 1500015000
ESL-5000-4ESL-5000-4 2000020000
ESL-xxxx-SDESL-xxxx-SD Model equipped with Special Shelter Model equipped with Special Shelter Diesel Engine. - VTV-ground shock Diesel Engine. - VTV-ground shock isolated and PVD-blast protected.isolated and PVD-blast protected.
NBC Filtration SystemsNBC Filtration Systems
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Automatic Modular Filtration Automatic Modular Filtration SystemsSystems
• Automatic NBC-filtration units are used for NBC- ventilation in Military Automatic NBC-filtration units are used for NBC- ventilation in Military Command Posts and Operational Shelters.Command Posts and Operational Shelters.
• Filtration system utilizes the data of NBC-detection system and changes to Filtration system utilizes the data of NBC-detection system and changes to close-up and filtrations modes without manual operation - increases the safety close-up and filtrations modes without manual operation - increases the safety of personnel inside the shelter.of personnel inside the shelter.
ESL-3000 ESL-3000 3000 M3000 M33/H /H (1765 CFM)(1765 CFM)CLEANED AIRCLEANED AIR
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
• The ESL-A-series provides an optional stand-by line that can be taken The ESL-A-series provides an optional stand-by line that can be taken into use at any time. into use at any time.
• The sophisticated control system monitors the performance of the The sophisticated control system monitors the performance of the NBC-filters, and automatically starts the operation of the stand-by line.NBC-filters, and automatically starts the operation of the stand-by line.
ESL-3000 ESL-3000 WITH STAND-BYWITH STAND-BYLINELINE2 x 3000 M2 x 3000 M33/H/H(2 x 1765 CFM)(2 x 1765 CFM)
Automatic Modular Filtration Automatic Modular Filtration SystemsSystems
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
• Sophisticated control system continuously balances the airflow within Sophisticated control system continuously balances the airflow within the NBC-filtration bank - maximizing the efficiency of NBC-filters. the NBC-filtration bank - maximizing the efficiency of NBC-filters.
• Filtration unit can be integrated to a building management system. Filtration unit can be integrated to a building management system.
Automatic Modular Filtration Automatic Modular Filtration SystemsSystems
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
• Main modules: Main modules: – NBC-blower module with main control valves and pre-NBC-blower module with main control valves and pre-
heating and pre-filtration system, heating and pre-filtration system, – NBC-filter modules with control and gastight closing NBC-filter modules with control and gastight closing
valves,valves,– Control panel. Control panel.
• The systems are completely ground shock isolatedThe systems are completely ground shock isolated
Automatic Modular Filtration Automatic Modular Filtration SystemsSystems
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Automatic modular systemsAutomatic modular systemsSimple installation at siteSimple installation at site
Installation requires only Installation requires only small amount of work, small amount of work, simply connect electrical simply connect electrical cables and ducts, and cables and ducts, and the unit is ready for the unit is ready for operation.operation.
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Temet ESL-CO2-230-B is fully Temet ESL-CO2-230-B is fully automatic Regenerative Carbon automatic Regenerative Carbon Dioxide Removal System.Dioxide Removal System.
The System is designed to be The System is designed to be used in any facility having a used in any facility having a gastight envelope that needs to gastight envelope that needs to be fully closed in dangerous be fully closed in dangerous situations. situations.
Removing carbon dioxide (CORemoving carbon dioxide (CO22 ) )
from the atmosphere is an from the atmosphere is an important function of a life important function of a life supporting system. supporting system.
COCO22 Regenerative Carbon Dioxide Regenerative Carbon Dioxide Removal SystemRemoval System
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
The ESL-CO2-230-B ensures safe stay The ESL-CO2-230-B ensures safe stay for persons duration a close-up mode, for persons duration a close-up mode, when no fresh, purified air is supplied when no fresh, purified air is supplied to the facilities.to the facilities.
This stand-alone system requires only This stand-alone system requires only connection to main power and existing connection to main power and existing ventilation ductwork and occupies less ventilation ductwork and occupies less space in the plant room than any other space in the plant room than any other corresponding system.corresponding system.
This is an important aspect especially in This is an important aspect especially in military hardened facilities where each military hardened facilities where each square meter of shelter space has square meter of shelter space has significant cost impact.significant cost impact.
COCO22 Regenerative Carbon Dioxide Regenerative Carbon Dioxide Removal SystemRemoval System
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Adsorption media Adsorption media reusable after reusable after regeneration cycleregeneration cycle• long button-up stay in long button-up stay in the shelter possiblethe shelter possible• based on solid amine based on solid amine materialmaterial - - no need for no need for stockpiling of stockpiling of adsorption material for adsorption material for refillrefill • less space neededless space needed
COCO22 Regenerative Carbon Dioxide Regenerative Carbon Dioxide Removal SystemRemoval System
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
TASCS TASCS Automatic Shelter Automatic Shelter Control SystemControl System
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
TASCS TASCS Automatic Shelter Control SystemAutomatic Shelter Control System
Cutting Edge Technology for NBC-Cutting Edge Technology for NBC-protective shelters:protective shelters:
•Automatic Control system for NBC-shelter Automatic Control system for NBC-shelter operation modes operation modes
•Smart NBC-filtration system integrated Smart NBC-filtration system integrated with CWA & N –detection systems with CWA & N –detection systems
•Control systems for Access & Passage Control systems for Access & Passage Ways Ways
•NBC-shelter testing features NBC-shelter testing features
•Training Modes for operating personnelTraining Modes for operating personnel
•Customised De-contamination cycles / Customised De-contamination cycles / procedures procedures
•Data-logging systems Data-logging systems
•Networking of TASCS SheltersNetworking of TASCS Shelters
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Other productsOther products
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Blast Valves PVD-seriesBlast Valves PVD-series
Diesel Engine Blast Diesel Engine Blast ValvesValves
•Maximum Gas flowMaximum Gas flow– PVD-50PVD-50 300 m300 m33/h/h– PVD-100 PVD-100 700 m700 m33/h/h– PVD-150 PVD-150 2000 m2000 m33/h/h– PVD-250 PVD-250 7000 m7000 m33/h /h
• Standard temperature models Standard temperature models up to 520 up to 520 ooC (968 F)C (968 F)
• High Temperature High Temperature applications up to 650 applications up to 650 ooC C (1202 F)(1202 F)
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
VTV-2G/35 Ground Shock IsolatorsVTV-2G/35 Ground Shock Isolators
- Floor & Wall mountingsFloor & Wall mountings- Ground Shock Isolation Ground Shock Isolation
factor more than 90%factor more than 90%- 50g ground shock 50g ground shock
isolated below 2gisolated below 2g
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
SJ-150 Cable and Tube PenetrationsSJ-150 Cable and Tube Penetrations
The SJ-150 wall sleeve system is designed The SJ-150 wall sleeve system is designed to make possible conduction of electric to make possible conduction of electric cables through blast resistant and gastight cables through blast resistant and gastight walls in hardened Civil Defence and Military walls in hardened Civil Defence and Military sheltersshelters
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Miscellaneous shelter equipmentMiscellaneous shelter equipment
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Soft NBC Soft NBC Airlocks for Airlocks for small shelterssmall shelters
Bed StretchersBed Stretchers
Miscellaneous shelter equipmentMiscellaneous shelter equipment
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Mobile ApplicationsMobile Applications
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
CV-90 FiltersCV-90 Filters
• For NBC filtration units in vehicles, navy For NBC filtration units in vehicles, navy vessels and collective protection tentsvessels and collective protection tents
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
• CV-90/50 30-50 mCV-90/50 30-50 m33/h/h• CV-90/170 100-170 mCV-90/170 100-170 m33/h/h
• Combined HEPA and Combined HEPA and activated carbon filtersactivated carbon filters
• Used in Sweden, Finland and Used in Sweden, Finland and Ireland among other Ireland among other countries countries
CV-90 FiltersCV-90 Filters
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
CCM - Contamination Screening ModuleCCM - Contamination Screening Module
• Used to rapidly screen Used to rapidly screen possible contamination and possible contamination and classify personsclassify persons
• Screening in 40 to 90 seconds, Screening in 40 to 90 seconds, possible to sort a large possible to sort a large number of people faster than number of people faster than by hand held monitorsby hand held monitors
• Used by Swedish Defense Used by Swedish Defense Forces, field proven in Forces, field proven in BalkansBalkans
• Consists of Consists of – cabincabin– IR heatingIR heating– detector unitdetector unit– closed loop ventilationclosed loop ventilation– CBRN filtration unitCBRN filtration unit
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
CCM - Contamination Screening ModuleCCM - Contamination Screening Module
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
FU-340-HAC UNITFU-340-HAC UNIT
• CBRN filtration, air CBRN filtration, air conditioning, heating conditioning, heating and ventilation and ventilation in in one mounting rackone mounting rack
• Applied in light Applied in light shelters, field shelters, field hospitals and hospitals and containerscontainers
• Used by Finnish and Used by Finnish and Swedish Defense Swedish Defense ForcesForces
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
FU-340, NAVAL CBRN FILTRATION SYSTEMFU-340, NAVAL CBRN FILTRATION SYSTEM
• Used by Swedish Navy in Used by Swedish Navy in minesweepers and missile minesweepers and missile boatsboats
• Fully non-magnetic Fully non-magnetic materials and for heavy-materials and for heavy-duty use duty use
• Two parallel Temet CV/90 Two parallel Temet CV/90 filters are used filters are used
• Air intake with water Air intake with water separator and air preheaterseparator and air preheater
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
FU-130 Portable Filtration UnitFU-130 Portable Filtration Unit
• Small portable Small portable CBRN filter unit for CBRN filter unit for up to 15 persons in up to 15 persons in small shelterssmall shelters
• Weight app. 20 kgWeight app. 20 kg
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Temet serviceTemet service
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
DESIGNER
OWNER
Living along projectLiving along project
MAIN CONTRACTOR
OPERATOR ORGANISATION
CONCEPTDEVELOPMENT
DESIGNING BIDDING CONSTRUCTION COMMISSIONING
DESIGNING SUPPORT•APPLICATION•OPERATION•FEATURES•DIMENSIONS•AVAILABLE VERSIONS•INSTALLATION DRAWINGS•BUDGETARY PRICING
PRODUCT SUBMITTALS•VERSION•APPLICATION•FEATURES•DIMENSIONS•TEST REPORTS•QUALITY REPORTS•INSPECTION PLANS•INSTALLATION DRAWINGS•INSTALLATIONINSTRUCTIONS
COMMISSIONING AND TRAINING•APPLICATION•FEATURES•QUALITY REPORTS•OPERATION INSTRUCTIONS•MAINTENANCEINSTRUCTIONS•SPARE PART LISTS
PROPOSAL•VERSION•FEATURES•DIMENSIONS•PRICE +•SUPPLIER DATA•REFERENCES•ETC.
CONCEPT•PRIMARY NEED •SECONDARY NEEDS•IS THIS POSSIBLE?•WHAT IS AVAILABLE?•WHICH ARE OPTIONS?•HOW IS IT DONEELSEWHERE?
VITAL LINKS TO OTHER AREAS OF DESIGING: LAYOUT, STRUCTURAL, VENTILATION, CABLING & DUCTING, ETC.
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Scope of Temet servicesScope of Temet services
• Temet R & D ServicesTemet R & D Services– Custom Product DesignCustom Product Design
• Temet ConsultingTemet Consulting– Assistance to Architects Assistance to Architects
and Engineers designing and Engineers designing shelters and protected shelters and protected buildingsbuildings
• Temet On-site ServicesTemet On-site Services– Installation SupervisionInstallation Supervision– Commissioning Commissioning
Supervision Supervision – Maintenance ServicesMaintenance Services– Shelter Testing ServicesShelter Testing Services
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Quality of Temet Shelter EquipmentQuality of Temet Shelter Equipment
• TemetTemet is the trademark for shelter is the trademark for shelter technology whenever high protection level technology whenever high protection level is required is required
• TemetTemet products are the result of intensive products are the result of intensive and continuous research, testing and and continuous research, testing and development work together with Civil development work together with Civil Defence and Military Authorities in Finland Defence and Military Authorities in Finland and abroad. and abroad.
• TemetTemet is ISO 9001:2000 certified and has is ISO 9001:2000 certified and has also product specific Quality Control also product specific Quality Control Agreements with the Technical Research Agreements with the Technical Research Centre of Finland/VTT Building and Centre of Finland/VTT Building and Transport, on all shelter products. The Transport, on all shelter products. The fabrication, testing and inspection can be fabrication, testing and inspection can be performed in accordance with Temet’s own performed in accordance with Temet’s own QA system, with Client’s specified QA QA system, with Client’s specified QA system or with the NATO AQAP-130 quality system or with the NATO AQAP-130 quality control procedures.control procedures.
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
ReferencesReferences
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
NON-CLASSIFIED REFERENCE PROJECTS NON-CLASSIFIED REFERENCE PROJECTS UNDERTAKEN BY TEMET IN 2003 - 04UNDERTAKEN BY TEMET IN 2003 - 04
PROJECT NAME OR CLIENT OR CONSIGNEE/ COUNTRY SCOPE OF SUPPLY OR CONTRACT PERIOD
IDENTIFICATION
Bantrel CP Knape associates / USA Blast Valves 2004
Underground Shelter SP Office / Hungary Sliding Blast Doors 2004
Ramstein Air Base Adisa Co. / Germany Blast Valves 2004
State Audit Bureau Boodai Trading / KuwaitComplete package of shelter
equipment 2004
OMIFCO Project CCC / Oman Blast Valves 2004
Project Bechtel / USA Blast Valves 2004
Sepangar Bay Navy Base / MalaysiaComplete package of shelter
equipment 2003-2004
HanWha-Project Hande Engineering / South Korea Heavy Duty Blast Doors 2003
Air Base Servicios y Proyectos Avanzados / Spain Blast Doors 2003
Nevada Test Site Bechtel / USA Blast Doors 2003
Security Facility Corus Bi-Steel / UK Special Blast Door 2003
Grane Indiana Mastercraft Mechanical Contractors / USA Blast Valves 2003
ULG-LSGO, Ruwais E.T.A. / UAE Blast Valves 2003
King Fahd HospitalMansouryah Est / Ministry of Health, Saudi
ArabiaComplete package of shelter
equipment 2002-2003
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
US Army Corps of Engineers Waterways Experiment Station
US Army Corps of Engineers European Division
US Army Corps of Engineers Middle East Division
US Army Corps of Engineers Far East Division
US Navy Facilities Engineer Command OICC Mediterranean
US Navy Facilities Engineer Command Atlantic Division
US Navy Civil Engineering Laboratory
US Air Force Europe
US Air Force Pacific
US Air Force Logistig Command
US Air Force Headquarters, Strategic Air Command
US Air Force Engineering Service Center
US Air Force Space Command
OTHER TEMET CUSTOMERSOTHER TEMET CUSTOMERS
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Department of Energy Pantex Nuclear Weapons Assembly Facility
Department of Energy Johnston Island Chemical Agent Disposal Facility
Lawrence Livermore National Laboratories
Los Alamos National Laboratories
Sandia National Laboratories
Hercules Aerospace Bacchu Works
Property Services Administration PSA (U.K)
Saudi Aramco
Kuwait National Petroleum Company
ADNOC, U.A.E
OTHER TEMET CUSTOMERSOTHER TEMET CUSTOMERS
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
MilestonesMilestones
1953 Temet Oy was established1953 Temet Oy was establishedwith production comprising gymwith production comprising gymequipment for primary schools and equipment for primary schools and subcontracting for the Finnishsubcontracting for the Finnishmetal industry.metal industry.
1958 Modern Civil Defense law1958 Modern Civil Defense lawincorporating obligations to build shelters incorporating obligations to build shelters was brought into effect inwas brought into effect inFinland.Finland.
1963 Shelter equipment were accountable 1963 Shelter equipment were accountable for 85% of the company’s turnover.for 85% of the company’s turnover.
1966 First export deliveries.1966 First export deliveries.
1980 Temet USA, Inc. was1980 Temet USA, Inc. wasestablished for marketing andestablished for marketing andPMI (Production Manufacturing,PMI (Production Manufacturing,Inc.) for manufacturing for theInc.) for manufacturing for theU.S. influenced market.U.S. influenced market.
1988 - 1991 High technology firms were 1988 - 1991 High technology firms were acquired.acquired.
1994 Strategic business units1994 Strategic business unitswere arranged as individualwere arranged as individualcompanies under the umbrellacompanies under the umbrellaof Finntemet Oy.of Finntemet Oy.
1994 - 2005 Period of heavy investment in 1994 - 2005 Period of heavy investment in R&D and marketing in all segments. R&D and marketing in all segments. Environics was consolidated in Temet Environics was consolidated in Temet Group 2003. Temet Instruments demerged Group 2003. Temet Instruments demerged by MBO arrangement in 2005.by MBO arrangement in 2005.
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Finntemet Oy Administration, Real estate, Finance
Temet Oy Shelter Technology
TVI Vision Oy Digital line scan cameras
Environics Oy Chemical Detection Technology
TEMET GROUPTEMET GROUP
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
CONTACTS IN TEMETCONTACTS IN TEMET
TEMET OYTEMET OYAsentajankatu 3Asentajankatu 3FIN-00880 HelsinkiFIN-00880 HelsinkiFINLANDFINLANDTel. Int. +358 9 759 001Tel. Int. +358 9 759 001Fax Int. +358 9 785 967Fax Int. +358 9 785 967
Internet: www.temet.com
Vice President, International Sales:Mr. Ilkka [email protected]
Regional Managers:
Asia Pacific RegionMr. Marko Nykä[email protected]
Middle East RegionMr. Ilkka [email protected]
EuropeMr. Antti [email protected]
North America Mr. Ilkka [email protected]
PROTECTIVE SOLUTIONSPROTECTIVE SOLUTIONS
Group