wcap-16182-np-a, revision 3, westinghouse bwr control rod bwr control rod cr 99 licensing report-...

Download WCAP-16182-NP-A, Revision 3, Westinghouse BWR Control Rod BWR Control Rod CR 99 Licensing Report- Update

Post on 25-Apr-2020

0 views

Category:

Documents

0 download

Embed Size (px)

TRANSCRIPT

  • Westinghouse Non-Proprietary Class 3

    WCAP-16182-NP-A November 2017 Revision 3

    Westinghouse BWR Control Rod CR 99 Licensing Report – Update to Mechanical Design Limits

    *** This record was final approved on 11/9/2017 3:13:35 AM. ( This statement was added by the PRIME system upon its validation)

  • Westinghouse Non-Proprietary Class 3

    *Electronically approved records are authenticated in the electronic document management system.

    Westinghouse Electric Company LLC 1000 Westinghouse Drive

    Cranberry Township, PA 16066, USA

    © 2017 Westinghouse Electric Company LLC All Rights Reserved

    WCAP-16182-NP-A Revision 3

    Westinghouse BWR Control Rod CR 99 Licensing Report – Update to Mechanical Design Limits

    Magnus Jinnestrand Flow Design, Loads and Structural Verification

    Björn Rebensdorff

    Nuclear Fuel, Global Product Management

    November 2017

    Technical Reviewer: Anghel Enica, Core Engineering *

    Licensing Reviewer: Bradley F. Maurer, Product Licensing *

    Approved: Sven E. Perzon, Manager * Flow Design, Loads and Structural Verification

    Edmond J. Mercier, Manager * Product Licensing

    *** This record was final approved on 11/9/2017 3:13:35 AM. ( This statement was added by the PRIME system upon its validation)

  • Westinghouse Non-Proprietary Class 3 ii

    WCAP-16182-NP-A November 2017 Revision 3

    TABLE OF CONTENTS

    Section Description

    A Final Safety Evaluation

    Letter from Dennis C. Morey (NRC) to J. A. Gresham (Westinghouse) , “Final Safety Evaluation for Westinghouse Electric Company (Westinghouse) Topical Report WCAP-16182-P/NP, Revision 3, “Westinghouse BWR Control Rod CR 99 Licensing Report – Update To Mechanical Design Limits” (TAC No. ME2630), with attachment “NRC Resolution Of Comments On Draft Safety Evaluation For Topical Report Safety Evaluation WCAP-16182-P/NP, Revision 3, “Westinghouse BWR Control Rod CR 99 Licensing Report – Update To Mechanical Design Limits” Westinghouse Electric Company. Project No. 700,” August 17, 2017.

    B Submittal of Topical Report

    Westinghouse Letter LTR-NRC-07-59, Revision 1, April 9, 2008, “Submittal of WCAP-16182-P-A Addendum 1 (P) / WCAP-16182-NP-A Addendum 1 (NP), "Westinghouse BWR Control Rod CR 99 Licensing Report- Addendum 1, Updated Design Limits,"

    Westinghouse Letter LTR-NRC-09-50, November 10, 2009, “Response to NRC Request for Additional Information Re: Westinghouse Electric Company Topical Report (TR) WCAP-16182-P-A, Addendum 1, Westinghouse BWR Control Rod CR 99 Licensing Report - Addendum 1, Updated Design Limits,” dated November 6, 2008 (TAC NO. MD7989) and Submittal of WCAP-16182-P-A/WCAP-16182-NP-A, Revision 1, “Westinghouse BWR Control Rod CR 99 Licensing Report - Update to Technical Design Limits,” dated October 2009.

    Westinghouse Letter LTR-NRC-10-18, March 24, 2010, “Request to withdraw Westinghouse Topical Report WCAP-16182-P-A Addendum 1 / WCAP-16182-NP-A Addendum 1, "Westinghouse BWR Control Rod CR 99 Licensing Report - Addendum 1, Updated Design Limits," (TAC No. MD7989).

    Westinghouse Letter LTR-NRC-15-89, November 3, 2015, “Submittal of WCAP-16182-P, Revision 2 and WCAP-16182-NP, Revision 2, "Westinghouse BWR Control Rod CR 99 Licensing Report - Update to Mechanical Design Limits."

    Westinghouse Letter LTR-NRC-16-42, June 27, 2016, “Submittal of WCAP-16182-P, Revision 3-Draft, and WCAP-16182-NP, Revision 3-Draft, "Westinghouse BWR Control Rod CR 99 Licensing Report- Update to Mechanical Design Limits."

    Westinghouse Letter LTR-NRC-16-60, August 16, 2016, “Submittal of WCAP-16182-P, Revision 3, and WCAP-16182-NP, Revision 3, "Westinghouse BWR Control Rod CR 99 Licensing Report- Update to Mechanical Design Limits."

    *** This record was final approved on 11/9/2017 3:13:35 AM. ( This statement was added by the PRIME system upon its validation)

  • Westinghouse Non-Proprietary Class 3 iii

    WCAP-16182-NP-A November 2017 Revision 3

    Section Description

    C Submittal of Responses to Requests for Additional Information

    Westinghouse Letter LTR-NRC-09-50, November 10, 2009, “Response to NRC Request for Additional Information Re: Westinghouse Electric Company Topical Report (TR) WCAP-16182-P-A, Addendum 1, Westinghouse BWR Control Rod CR 99 Licensing Report - Addendum 1, Updated Design Limits,” dated November 6, 2008 (TAC NO. MD7989) and Submittal of WCAP-16182-P-A/ WCAP-16182-NP-A, Revision 1, “Westinghouse BWR Control Rod CR 99 Licensing Report - Update to Technical Design Limits,” dated October 2009.

    Westinghouse Letter LTR-NRC-11-15, Revision 1, June 6, 2011, “Response to the NRCs Request for Additional Information RE: Westinghouse Electric Company Topical Report WCAP-16182-P-A, Revision 1, "Westinghouse BWR Control Rod CR 99 Licensing Report- Update to Mechanical Design Limits" (TAC No. ME2630).

    ` Westinghouse Letter LTR-NRC-12-48, June 21, 2012, “Response to the NRC's Request for Additional Information on WCAP-16182-P-A, Revision 1, "Westinghouse BWR Control Rod CR 99 Licensing Report- Update to Mechanical Design Limits."

    D Audits

    Westinghouse Letter LTR-NRC-12-67, September 16, 2012, “Resolution of Open Items from NRC Audit on WCAP-16182-P-A, Revision 1, "Westinghouse BWR Control Rod CR 99 Licensing Report- Update to Mechanical Design Limits."

    Westinghouse Letter LTR-NRC-12-76, October 17, 2012, Supplemental Information to Open Items from NRC Audit on WCAP-16182-P-A, Revision 1, "Westinghouse BWR Control Rod CR 99 Licensing Report- Update to Mechanical Design Limits."

    Westinghouse Letter LTR-NRC-16-40, June 15, 2016, “Meeting Minutes for the NRC Combined Audit of WCAP-16182-P, Rev. 2, "Westinghouse BWR Control Rod CR 99 Licensing Report - Update to Mechanical Design Limits," and WCAP-17769-P, Rev. 0, "Reference Fuel Design SVEA-96 Optima3."

    *** This record was final approved on 11/9/2017 3:13:35 AM. ( This statement was added by the PRIME system upon its validation)

  • Westinghouse Non-Proprietary Class 3

    WCAP-16182-NP-A November 2017 Revision 3

    Section A

    Final Safety Evaluation

    *** This record was final approved on 11/9/2017 3:13:35 AM. ( This statement was added by the PRIME system upon its validation)

  • OFFICIAL USE ONLY- PROPRIETARY INFORMATION

    OFFICIAL USE ONLY- PROPRIETARY INFORMATION

    August 17, 2017 Mr. James A. Gresham, Manager Regulatory Compliance and Plant Licensing Westinghouse Electric Company 1000 Westinghouse Drive Cranberry Township, PA 16066

    SUBJECT: FINAL SAFETY EVALUATION FOR WESTINGHOUSE ELECTRIC

    COMPANY (WESTINGHOUSE) TOPICAL REPORT WCAP-16182-P/NP, REVISION 3, “WESTINGHOUSE BWR CONTROL ROD CR 99 LICENSING REPORT – UPDATE TO MECHANICAL DESIGN LIMITS” (TAC NO. ME2630)

    Dear Mr. Gresham:

    By letter dated November 10, 2009 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML093240365), Westinghouse Electric Company (Westinghouse) submitted for U. S. Nuclear Regulatory Commission (NRC) staff review Topical Report (TR) WCAP-16182-P-A/WCAP-16182-NP-A, Revision 1, “Westinghouse BWR Control Rod CR 99 Licensing Report – Update to Mechanical Design Limits.” As a result of the NRC staff requests for additional information (RAIs) and audits, Westinghouse submitted WCAP-16182-P, Revision 2, and WCAP-16182-NP, Revision 2 of WCAP-16182-P-A/WCAP-16182-NP-A, Revision 1, “Westinghouse BWR Control Rod CR 99 Licensing Report – Update to Mechanical Design Limits,” by letter dated November 3, 2015 (ADAMS Accession No. ML15316A197). As a result of the NRC staff RAIs and audits, Westinghouse submitted Revision 3 of WCAP-16182- P/NP by letter dated August 16, 2016 (ADAMS Accession No. ML16235A107).

    The NRC staff has found that WCAP-16182-P/NP, Revision 3, “Westinghouse BWR Control Rod CR 99 Licensing Report – Update to Mechanical Design Limits” is acceptable for referencing in licensing applications provided that the surveillance plan stipulated in the Section 5.0 and applicability defined in Section 6.0 of the enclosed NRC final SE are met.

    NOTICE: Enclosure 2 transmitted herewith contains proprietary information. When separated from Enclosure 2, this document is decontrolled.

    WCAP-16182-NP-A _____________________________________________________________________________________

    November 2017 Revision 3

    *** This record was final approved on 11/9/2017 3:13:35 AM. ( This statement was added by the PRIME system upon its validation)

  • OFFICIAL USE ONLY- PROPRIETARY INFORMATION

    OFFICIAL USE ONLY- PROPRIETARY INFORMATION - 2 -

    Our acceptance applies only to material provided in the subject TRs. In accordance with the guidance provided on the NRC website, we request that Westinghouse publish accepted proprietary and non-proprietary versions of these TRs within three months of receipt of this letter. The accepted versions shall incorporate this letter and the enclosed final SE after the title page. Also, they must contain historical review information, including NRC requests for additional information (RAIs) and your responses. The accepted versions shall include an "-A" (designating accepted) following the TRs identification symbol.

    As an alternative to including the RAIs and RAI responses behind the title page, if changes to the TRs were provided to the NRC