WBEA Passive Sampler Validation Study for NH3 and HNO3 Compare Ogawa and Radiello PS with ADS Use the following specific adsorbing material: Sodium chloride and Nylon for HNO3 Citric and phosphorous acid for NH3 Assess DL, precision & accuracy at 2 sites: AMS01 Fort McKay (FMK), AMS06 Fort McMurray (FMM) Expose monthly for total 5 months Start on June 1 , 2011

Upload: malachi-marcon

Post on 31-Mar-2015

220 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: WBEA Passive Sampler Validation Study for NH3 and HNO3 Compare Ogawa and Radiello PS with ADS Use the following specific adsorbing material: Sodium chloride

WBEAPassive Sampler Validation Study

for NH3 and HNO3• Compare Ogawa and Radiello PS with ADS• Use the following specific adsorbing material:

• Sodium chloride and Nylon for HNO3• Citric and phosphorous acid for NH3

• Assess DL, precision & accuracy at 2 sites:• AMS01 Fort McKay (FMK),• AMS06 Fort McMurray (FMM)

• Expose monthly for total 5 months• Start on June 1 , 2011

Page 2: WBEA Passive Sampler Validation Study for NH3 and HNO3 Compare Ogawa and Radiello PS with ADS Use the following specific adsorbing material: Sodium chloride

Adsorbent Cartridge

Inlet Box

Samplers and Components

Filter Pack

Denuder Coupler /End-cap (shipping)

2/3 DenudersSCL - CA/PA

Impactor Coupler

Elutriator Acceleration Jet for PM2.5

Annular Denuder System (ADS)

Ogawa PSCA - SCL - NYL

Radiello PSPA

Left & Right Collection Pad analyzed together (composite)

Diff

user

Sample Flow

ADS inlet is positioned at same height above ground as all PS units !!

Page 3: WBEA Passive Sampler Validation Study for NH3 and HNO3 Compare Ogawa and Radiello PS with ADS Use the following specific adsorbing material: Sodium chloride

Coating solutions are 1% (w/w) in DI water: SCL …sodium chloride, CA …citric acid, PA …phosphorous acid; NYL …Nylon.

Sample Media Required for Months 1 - 2

Field Blank

ADSD

1-SC

L1D

2-SC

L1D

3-PA

1

FP1

EI1

D1-

SCL2

D2-

CA2

D3-

CA2

FP2

EI2 cap

D1-

SCL0

FD

2-CA

0FD

3-PA

0FFP0

D-S

CL0L

D-C

A0L

D-P

A0L

Lab Blank

Denuders, EI and FP are shipped separately and assembled in field prior to sampling. Field Blanks are treated like samples except that they remain unexposed. ADS inlets (EI1 and EI2) are positioned at exact same height above ground as the PS units. With each monthly shipment one set of Lab Blanks is prepared and stored in Lab until field media are being analyzed.

OgaCA0F OgaCA2OgaCA1

Passive Samplers (PS)

RadPA1 RadPA2RadPA0F

OgaSCL0F OgaSCL2OgaSCL1

OgaNYL1 OgaNYL2OgaNYL0F

Field Blank

Lab Blank DUP1 DUP2

OgaNYL0L

OgaSCL0L

OgaCA0L

RadPA0L

ship to each site (2x)

ship to each site (2x)keep stored (1x)

Page 4: WBEA Passive Sampler Validation Study for NH3 and HNO3 Compare Ogawa and Radiello PS with ADS Use the following specific adsorbing material: Sodium chloride

Coating solutions are 1% (w/w) in DI water: SCL …sodium chloride, CA …citric acid, PA …phosphorous acid; NYL …Nylon.

Sample Media Required for Months 3 - 5

Field Blank

ADSD

1-SC

L1D

2-PA

1

EI1

D1-

SCL2

D2-

CA2

EI2 cap

D1-

SCL0

FD

2-CA

0FD

3-PA

0FFP0

D-S

CL0L

D-C

A0L

D-P

A0L

Lab Blank

ADS denuders D2-SCL1 and D3-CA2 are omitted!

OgaCA0F OgaCA2OgaCA1

Passive Samplers (PS)

RadPA1 RadPA2RadPA0F

OgaSCL0F OgaSCL2OgaSCL1

OgaNYL1 OgaNYL2OgaNYL0F

Field Blank

Lab Blank DUP1 DUP2

OgaNYL0L

OgaSCL0L

OgaCA0L

RadPA0L

ship to each site (2x)

ship to each site (2x)keep stored (1x)

FP1 FP2