wave 1200 ip44 1180 - sg lighting · [email protected] sg leuchten gmbh nordstrasse 53...

2
SG Armaturen AS Skytterheia 25 N-4790 Lillesand Tel: +47 37 50 03 00 [email protected] www.sg-as.no SG Lighting LTD Tel: +47 37 50 03 00 [email protected] www.sglighting.co.uk SG Armaturen AB Tel: +46 31 81 71 10 [email protected] www.sg-ab.se SG Armaturen A/S Tel: +45 70 70 72 13 [email protected] www.sg-as.dk SG Lighting SA/NV Tel: +32(0) 15 20 72 71 [email protected] www.sglighting.net SG Lighting Co Ltd. Tel: +86 769 88 49 20 88 [email protected] www.sg-as.com SG Armaturen Oy info@sg-oy.fi www.sg-oy.fi SG Lighting SA/NV Tel: +33(0) 4 94 93 00 00 [email protected] www.sglighting.net SG Leuchten GmbH Tel: +49 40 23 99 44 59 [email protected] www.sg-leuchten.de NORWAY UNITED KINGDOM SWEDEN DENMARK BENELUX INTERNATIONAL FINLAND FRANCE GERMANY Rev: 18.12.2019 1215mm Wave 1200 230V, 50/60Hz (Sensor 50Hz) Dipswitch 1 2 ON 1 2 ON 1 2 ON 1 2 ON Standard mA 800 900 975 1050 lm 76% 85% 93% 100% 0,5 – 1,0 mm 2 8 mm 1,5 – 2,5 mm 2 12 mm ca. 10° (max. 20°) Max. 16A IP 44 Sensor No Sensor IP 20 ! 3 N N N L L N 1 L’ L 2 N’ NO: Kan kun installeres og vedlikeholdes av en registrert installasjonsvirksomhet. DK: Må kun installeres og vedligeholdes af uddannet elektriker. SE: Skall installeras och underhållas av behörig elektriker. EN: Only to be installed and maintained by an authorized electrician. FR: Doit être installé et maintenu par un électricien qualifié. NL: Mag alleen geïnstalleerd en onderhouden worden door een bevoegde elektricien. DE: Dieses Produkt darf nur durch autorisiertes Personal (z.B. Elektro- Installateur) angeschlossen, in Betrieb genommen und gewartet werden. FI: Asentaa ja huoltaa saa vain valtuutettu sähköasentaja NO: Skru av strømmen før montering. DK: Sluk for strømmen inden montering. SE: Stäng av strömmen innan montering. EN: Turn off power before installing. FR: Couper le courant avant l’installation. NL: Stroom uitschakelen voor u het toestel installeert. DE: Vor Installationsarbeiten den Strom abschalten. FI: Sammuta virta ennen kytkemistä IP44

Upload: others

Post on 19-May-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Wave 1200 IP44 1180 - SG Lighting · info.benelux@sglighting.net SG Leuchten GmbH Nordstrasse 53 59399 Olfen GERMANY Branch offi ce: Tlf:+49 2595 3870 725 info@sg-leuchten.de SG

SG Armaturen AS

Skytterheia 25N-4790 Lillesand

Tel: +47 37 50 03 00fi [email protected] SG Lighting LTD

Tel: +47 37 50 03 [email protected]

SG Armaturen ABTel: +46 31 81 71 [email protected]

SG Armaturen A/STel: +45 70 70 72 [email protected]

SG Lighting SA/NVTel: +32(0) 15 20 72 [email protected]

SG Lighting Co Ltd.Tel: +86 769 88 49 20 [email protected] www.sg-as.com

SG Armaturen [email protected] www.sg-oy.fi

SG Lighting SA/NVTel: +33(0) 4 94 93 00 [email protected]

SG Leuchten GmbHTel: +49 40 23 99 44 [email protected]

NORWAY

UNITED KINGDOM

SWEDEN DENMARK

BENELUX INTERNATIONALFINLAND

FRANCE GERMANY

Rev:

18.

12.2

019

1215mm

Wave 1200

230V, 50/60Hz (Sensor 50Hz)

Dipswitch

1 2

ON

1 2

ON

1 2

ON

1 2

ON

180 mA

205 mA

230 mA

255 mA

1 2

ON

1 2

ON

1 2

ON

1 2

ON

180 mA

205 mA

230 mA

255 mA

1 2

ON

1 2

ON

1 2

ON

1 2

ON

180 mA

205 mA

230 mA

255 mA

1 2

ON

1 2

ON

1 2

ON

1 2

ON

180 mA

205 mA

230 mA

255 mA

Standard

mA 800 900 975 1050

lm 76% 85% 93% 100%

0,5 – 1,0 mm2

8 mm

1,5 – 2,5 mm2

12 mm

ca. 10° (max. 20°)

Max. 16A

IP 44

Sensor No Sensor

IP 20

!

N 21

N 21

N LE

N 1 2 3

N L L` N`

N 1 - +

DA2

DA1

N 21 3

N L

N LE

N 21

N 21

N LE

N 1 2 3

N L L` N`

N 1 - +

DA2

DA1

N 21 3

N L

N LE

3N

N

NL

L N

1L’

L

2N’

151

,02

1180

151,02

52,

15

NO: Kan kun installeres og vedlikeholdes av en registrert installasjonsvirksomhet.DK: Må kun installeres og vedligeholdes af uddannet elektriker.SE: Skall installeras och underhållas av behörig elektriker.EN: Only to be installed and maintained by an authorized electrician.FR: Doit être installé et maintenu par un électricien qualifié.NL: Mag alleen geïnstalleerd en onderhouden worden door een bevoegde elektricien.DE: Dieses Produkt darf nur durch autorisiertes Personal (z.B. Elektro-Installateur) angeschlossen, in Betrieb genommen und gewartet werden.FI: Asentaa ja huoltaa saa vain valtuutettu sähköasentaja

NO: Skru av strømmen før montering.DK: Sluk for strømmen inden montering.SE: Stäng av strömmen innan montering.EN: Turn off power before installing.FR: Couper le courant avant l’installation.NL: Stroom uitschakelen voor u het toestel installeert.DE: Vor Installationsarbeiten den Strom abschalten.FI: Sammuta virta ennen kytkemistä

IP44

Page 2: Wave 1200 IP44 1180 - SG Lighting · info.benelux@sglighting.net SG Leuchten GmbH Nordstrasse 53 59399 Olfen GERMANY Branch offi ce: Tlf:+49 2595 3870 725 info@sg-leuchten.de SG

SG Armaturen ASSG Armaturen ASSvåbekk 15Svåbekk 154790 Lillesand4790 LillesandNORGENORGE

Corporate offi ce:Corporate offi ce:

www.sg-as.nowww.sg-as.no

Tlf:+47 37 50 03 00Tlf:+47 37 50 03 00fi [email protected] [email protected]

SG Lighting SA/NV73 rue de Saint Mandrier83140 Six Fours Les PlagesFRANCE

Branch offi ce:

www.sglighting.net

Tlf:+33(0) 4 94 93 00 [email protected]

Branch offi ce:

Tlf:+45 70 70 72 13

www.sg-as.dk

SG Armaturen A/SEgebakken 197400 Herning DANMARK

[email protected]

SG Lighting SA/NVBlokhuisstraat 472800 Mechelen Noord IBELGIQUE/BELGIË

Branch offi ce:

Tlf:+32(0) 15 20 72 71

www. [email protected]

SG Leuchten GmbHNordstrasse 5359399 OlfenGERMANY

Branch offi ce:

Tlf:+49 2595 3870 725

[email protected]

SG Armaturen ABAugust Barksg. 30B421 32 Västra FrölundaSVERIGE

Branch offi ce:

Tlf:+46 31 81 71 10

[email protected]

Rev

: 03.

05.2

017

NL

L

N

N’

L

N

L

N

Sensor Slave Slave

L

N N

Sensor

L’L

N’

L’

L

N

N’

L

N

L

N

Sensor Slave Slave

L

N

Sensor

L’

N

L

N’

L’

PE

40-60% 60-80%

Fe

0-10% 0% 80-90%

40-60% 60-80%

80-90% 0-10% 0%

100%

75%

50%

25%

10%

1 2 3

4

4

1030

Standby power < 0.5W

Microwave frequency 5.8GHz+/-75MHz

Microwave power < 0.2mW

Max 400W

Sensor + Basic light:

Sensor:

I I I I

I I I I I I I I I I I I I I

I I I I I I I I I I I I I I

100%

100%

0%

2W

HC009S sensor

230V, 50Hz