water requirement consumption domestic flushing...
TRANSCRIPT
Water Requirement
S.No Description No. of
occupants
Consumption
per head
(LPCD)
Domestic
(KLD)
Flushing
(KLD)
Total
(KLD)
1 Cottages 118
Rooms
236 320 65 11 76
2 Restaurant
60
240 70 13 4 17
3 Residential
staff
18 135 1.6 0.8 2.5
4 Non
residential
staff
42 45 1.2 0.6 2.0
5 Swimming
pool
- - 15 15
6 Spa and
other
facilities
- - 8 8
Total 536 104 24 128
Water Balance
Sewage Generated
(85% domestic & 100%
flushing) 113 KLD
STP Capacity 125 KLD
Total treated sewage
water (95%) 107 KLD
Green Belt (22536 Sq.m)
70 KLD
Raw water
104 KLD
Swimming pool
15 KLD
Toilet Flushing
24 KLD
Cooling Tower
13 KLD
132.67 A
S P
ER
S
IT
E
3.75M WIDE SERVICE ROAD 3.75M WIDE SERVICE ROAD
337.95 AS PER SITE
117.81 A
S P
ER
S
IT
E
RAINWATER HARVESTING TRENCHRAINWATER HARVESTING TRENCH
STAFF
ENTRY/EXIT
Gate & Compound wall Detail
( Not to Scale)
DWARF WALL DETAIL
6000
Section of
Compound wall
1000
200
SECTION - XX (SCALE 1:50)
ELEVATION (SCALE 1:50)
SECURITY PLAN
Finished ground level
2000
GRAVELS 5 TO 10MM
COARSE SAND 1.5 TO 2MM
BOULDERS
5 TO 20MM
2000
DT-103 DT-102 DT-101
LICENSED SURVEYOR'S SIGNATURE
STRUCTURAL ENGINEER'S SIGNATURE
OWNER'S SIGNATURE
ARCHITECT'S SIGNATURE
COLOR INDEX
PLOT BOUNDARY
ROAD
PROPOSED
DRAWING TITLE
SITE PLAN
N
SCALE - 1 :350
SPECIFICATION
SCHEDULE OF JOINERY
SHEET NO - 1/7
FOUNDATION:
R.C.C RAFT FOUNDATION OVER A BED OF 1:4:8 SAND FILLING.
SUPER STRUCTURE:
100 m THK. INTERNAL & 200 mm THK.EXTERNAL WALLS IN C.M 1:5
WITH PLASTER IN C.M 1:5
R.C.C WORK :
R.C COLUMNS,BEAMS,SLABS,LINTELS, AND SUNSHADES IN 1:2:4
MIX ADEQUATELY REINFORCED.
FLOORING : CERAMIC FLOORING.
WEATHERING COURSE :
ONE SET OF BRICK JELLY LIME CONCRETE MIXED WITH CRUDE
OIL POINTED AND LAID TO SLOPE.
LOCATION PLAN
SCALE : N.T.S.
COMPOUND WALL DETAILS SECURITY CABIN DETAILS RECHARGE PIT DETAILS
RAFT FOUNDATION DETAIL
TYPE
D1
D2
WIDTH HEIGHTDESCRIPTION
DOOR
DOOR
DOOR
1800
1500
1000
800
2100
2100
2100
2100
925
2100
750
2100
2000
1050
4000
1050
900 2100
1400 2100
2100
D3 1400
2100
DOOR
DOOR
DOOR
DOOR
DOOR
GLASS DOOR
GLASS DOOR
SWINGING DOOR
REFRIGERATOR DOOR
FIRE RESCUE DOOR
FIXED GLASS
D4 1200
D5
D6
D7
D8
GD1
GD2
SD
RD
FRD
FG
2100
2100
2100
2100
LICENSED SURVEYOR'S SIGNATURE
STRUCTURAL ENGINEER'S SIGNATURE
OWNER'S SIGNATURE
ARCHITECT'S SIGNATURE
COLOR INDEX
PLOT BOUNDARY
ROAD
PROPOSED
DRAWING TITLE
SECTION-A1, A2, A3
SCALE - 1 :200
SPECIFICATION
SCHEDULE OF JOINERY
SHEET NO - 7/7
FOUNDATION:
R.C.C RAFT FOUNDATION OVER A BED OF 1:4:8 SAND FILLING.
SUPER STRUCTURE:
100 m THK. INTERNAL & 200 mm THK.EXTERNAL WALLS IN C.M 1:5
WITH PLASTER IN C.M 1:5
R.C.C WORK :
R.C COLUMNS,BEAMS,SLABS,LINTELS, AND SUNSHADES IN 1:2:4
MIX ADEQUATELY REINFORCED.
FLOORING : CERAMIC FLOORING.
WEATHERING COURSE :
ONE SET OF BRICK JELLY LIME CONCRETE MIXED WITH CRUDE
OIL POINTED AND LAID TO SLOPE.
NOTE : UNDER GROUND SUMP AND OVER HEAD WATER TANK
ARE SCIENTIFICALLY CLOSED.
ELEVATIONS-A & B
TOPOGRAPHICAL SURVEY AT VADANENMELI,THIRUVIDANTHAI,KANCHIPURAM Dt..
M/s A.R.RESORTS INDIA PVT.LTD.,148, Dr.RADHAKRISHNAN SALAI,
4.SURVEY DONE-BOUNDARY AS IDENTIFIED BY THE CLIENT.
3. BENCH MARK IS BASED ON THE GATE PILLER
2. ALL DIMENSION ARE IN METER AND FEET.
AND ITS VALUE IS +100.000
1. SURVEY DONE DURING AUG-2015.
TOTAL AREA OF
THE SITE
SYMBOL DESCRIPTION
43067.336463572.947
10.642
RELIABLE CONSULTANTSS
1:750DATE:DRAWN:
27.08.2015K.Vinoth 01.DRG.NO:
SCALE:
A1
CHECKED: REV.
K.Saravanan 00
MYLAPORE,CHENNAI-600 004.