wall mounted j series introduction

16
WM-J Training WM-J Training Wall Mounted J series Wall Mounted J series Introduction Introduction

Upload: deliz

Post on 12-Jan-2016

48 views

Category:

Documents


0 download

DESCRIPTION

Wall Mounted J series Introduction. Air Filter. Bio AB + Titanium Apatite. Introduction. 1st Joint – Development project btw Daikin Japan & OYLM. * Stylish Flat Panel. *Higher Energy Efficiency Certified model in Eurovent Directory 5WM10JR – participate in Programme (AC1) - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Wall Mounted J series  Introduction

WM-J TrainingWM-J Training

Wall Mounted J series Wall Mounted J series

Introduction Introduction

Page 2: Wall Mounted J series  Introduction

WM-J TrainingWM-J Training

Introduction1st Joint – Development project btw Daikin Japan & OYLM

* 5 Selectable Fan Speeds New SCR Indoor fan motor

Given more choice on preferable fan speed.

New Handset G17/18Silent & Turbo function

*Better IAQ using Bio-Engineering IAQ solution which combines superior air purifying of bio filter with deodorizing features of titanium filter.

*Higher Energy EfficiencyCertified model in Eurovent Directory5WM10JR – participate in Programme (AC1)

European Energy Rating of A/A

* Stylish Flat Panel* Stylish Flat Panel

Bio AB + Titanium ApatiteBio AB + Titanium Apatite

Air FilterAir Filter

INTRODUCTIONINTRODUCTION

Page 3: Wall Mounted J series  Introduction

WM-J TrainingWM-J Training

EUROVENT www.eurovent-certification.com

OYL R&D participated: Comfort Air Conditioners up to 12 kW

(AC1) Fan Coil Unit (FC) Liquid Chilling Packages (LCP)

Page 4: Wall Mounted J series  Introduction

WM-J TrainingWM-J Training

CERTIFICATES: AC1 OYL RESEARCH Diploma 2007

Page 5: Wall Mounted J series  Introduction

WM-J TrainingWM-J Training

PRODUCT RANGE

kW

HP

2.5

1.0

3.5

1.5

5

2.0

6

2.5

R410A

R22

5WM10J(R)5LC10C(R)J

WM09J(R)LC09C(R)

5WM15J(R)5LC15C(R)J

WM15J(R)LC15C(R)

WM20J(R)MLC20C(R)

MWM25J(R)MLC25C(R)

AVAILABLE UNDER DEVELOPMENT

Introduction

Page 6: Wall Mounted J series  Introduction

WM-J TrainingWM-J Training

APPEARANCE DIFFERENTIATION

MCQUAY Grille

ACSON Grille

Page 7: Wall Mounted J series  Introduction

WM-J TrainingWM-J Training

FEATURES HIGHLIGHTS

BETTER INDOOR AIR QUALITY by using Bio-Engineering Technology

Photo Catalytic Deodorizing – Titanium Apatite Filter

A new material combining the absorption capability of apatite and the photo catalyst capability of titanium oxide Dissolves absorbed substance such as odors and harmful airborne particles into harmless Water (H2O) and Carbon Dioxide (CO2) by photo catalytic.

Anti-Virus – Bio Antibody Filter

A special moisture-retaining filter material contains with lgY antibody which obtain from Extraction Technique. Deactivates up to 99.99% various airborne infectious viruses within 1 minute.*Neutralization of virus as a result of natural antigen-antibody reaction.

* Proven through joint research with Waseda University (Japan) , Japanese Ministry of Health, Labour and Welfare and National Institute of Infectious Diseases (Japan).

1

PROTECTION 1

PROTECTION 2

Page 8: Wall Mounted J series  Introduction

WM-J TrainingWM-J Training

IgY Extraction Technique

Introduction

Page 9: Wall Mounted J series  Introduction

WM-J TrainingWM-J Training

PhotoCatalytic Mechanism by TITANIUM OXIDE

Introduction

Page 10: Wall Mounted J series  Introduction

WM-J TrainingWM-J Training

Absorption Power & Dissolution Efficiency is DOUBLED with APATITE

Introduction

Page 11: Wall Mounted J series  Introduction

WM-J TrainingWM-J Training

Bio Antibody Filter Storage period – 3 yearsEffectiveness period – 12 months after unpacking.

Titanium Apatite FilterEffectiveness period – 3 yearsMaintenance – wash with pure water every 6 months.

Bio AB Filter

Titanium Apatite Filter

Filter Frame

1. Bio AB filter is packed inside hermitically sealed bag.

2. Remove only prior to installation

3. Slip the filter in between filter frame and titanium apatite filter.

INSTALLATION PROCEDURE of Bio Antibody Filter & Titanium Apatite Filter

Introduction

Page 12: Wall Mounted J series  Introduction

WM-J TrainingWM-J Training

ENERGY EFFICIENCY

FEATURES HIGHLIGHTS

2

MODEL Indoor 5WM10J(R) 5WM10G(R) 5WM15J(R) 5WM15G(R)

Outdoor 5SL10C(R)J 5SL10C(R) 5SL15C(R)J 5SL15C(R)

RATED CAPACITY (W)

Cooling 2650 2780 3150 3520

Heating 2800 2780 3380 3520

ENERGY EFFICIENCY (W/W)

Cooling 3.21 (A) 3.02 (B) 2.88 (C) 2.93 (C)

Heating 3.61 (A) 3.60 (A) 3.42 (B) 3.23 (C)

DIMENSION H x W x D (mm)

Indoor 288 x 800 x 204 260 x 899 x 198 288 x 800 x 204 260 x 899 x 198

Outdoor 540 x 700 x 250 540 x 700 x 250 540 x 700 x 250 540 x 700 x 250

R410A

R22 MODEL Indoor WM09J(R) WM09G(R) WM15J(R) WM15G(R)

Outdoor SL09C(R) SL09C(R) SL15C(R) SL15C(R)

RATED CAPACITY (W)

Cooling 2462 2580 3458 3520

Heating 2638 2520 3810 3520

ENERGY EFFICIENCY (W/W)

Cooling 2.66 2.84 2.90 3.20

Heating 3.52 3.36 3.58 3.59

DIMENSION H x W x D (mm)

Indoor 288 x 800 x 204 260 x 899 x 198 288 x 800 x 204 260 x 899 x 198

Outdoor 540 x 700 x 250 540 x 700 x 250 540 x 700 x 250 540 x 700 x 250

Class A/A in European Energy Rating

Page 13: Wall Mounted J series  Introduction

WM-J TrainingWM-J Training

SOUND LEVEL PRESSURE IMPROVEMENT

FEATURES HIGHLIGHTS

3

NEW SCR Indoor Fan Motor Given more choice on preferable fan speed. Step-less change of fan speed resulting in smooth air flow

Silent Mode – SLP as low as 25BA Turbo Mode – run in 20 minutes given max air flow for quickly cool down

INDOOR 5WM10J(R) / WM09J(R)

(5)WM10G(R) (5)WM15J(R) (5)WM15G(R)

Air flow (cfm)

SLP (dBA)

Air flow (cfm)

SLP (dBA)

Air flow (cfm)

SLP (dBA)

Air flow (cfm)

SLP (dBA)

FAN SPEED

TURBO 357 39 - - 387 41 - -

HIGH 335 38 300 39 346 40 345 42

MED 279 33 250 34 293 35 285 36

LOW 222 27 200 28 240 29 220 29

SILENT 219 25 - - 237 27 - -

4 5 SELECTABLE FAN SPEED

Page 14: Wall Mounted J series  Introduction

WM-J TrainingWM-J Training

NEW LCD REMOTE CONTROLLER G17/18

FEATURES HIGHLIGHTS

5

Sleep Mode

Set temperature is increased / decreased gradually once sleep mode is activated to ensures a comfortable environment for restful sleep.

Turbo Mode

Indoor fan will running at TURBO speed (at HIGH speed in WM-G) for 20 minutes enables required set temperature achieved in a short time.

* Bigger LCD Display* Real Time Clock Display* 2 sets of Personalized Setting - Operating mode (Heat, Cool, Dry, Fan, Auto), ON/OFF Timer, Temperature & Fan Speed * Turbo Mode * Sleep Mode (WM-J series only)* Silent Mode (WM-J series only)* Ionizer (WM-G series only)

Page 15: Wall Mounted J series  Introduction

WM-J TrainingWM-J Training

WM-J vs WM-G

FEATURES WM-J SERIES WM-G SERIES

IAQ Bio Antibody FilterTitanium Apatite Filter

Negative Ion GeneratorNano PhotocatalystNano Silver

Controller (G17/18)

Sleep Mode -

Silent Button -

Ionizer Button -

Selectable Fan speed

5 fan speed (SH/H/M/L/SL) 3 fan speed (H/M/L)

Turbo Mode Turbo fan speed High fan speed

CONCLUSION

Page 16: Wall Mounted J series  Introduction

WM-J TrainingWM-J Training

THANK YOU