wall-hung condensing combination boilers with...
TRANSCRIPT
![Page 1: WALL-HUNG CONDENSING COMBINATION BOILERS WITH ...tulips.bg/wp-content/uploads/2017/02/ctc_itaca_kc... · Electric protection rating IPX5D IPX5D IPX5D Gas fitting Ø G 1/2 G 1/2 G](https://reader034.vdocuments.mx/reader034/viewer/2022052015/602c3c29708a8a2b156eec7a/html5/thumbnails/1.jpg)
ITACA KC
Pre-set to run on natural gas or LPG
Available heat outputs:
24kW
28kW
32kW
COND
ENSI
NG B
OIL
ERS
WALL-HUNG CONDENSING COMBINATION BOILERS WITH INSTANTANEOUS PRODUCTION OF HOT WATER
➲ Modulation range 1:9
➲ Touch screen user interface
➲ Modulating pump
➲
Control of 2 heating zones fitted as standard via two temperature probes (probes not supplied)
➲
Controls to manage three different types of solar thermal systems fitted as standard
GB
![Page 2: WALL-HUNG CONDENSING COMBINATION BOILERS WITH ...tulips.bg/wp-content/uploads/2017/02/ctc_itaca_kc... · Electric protection rating IPX5D IPX5D IPX5D Gas fitting Ø G 1/2 G 1/2 G](https://reader034.vdocuments.mx/reader034/viewer/2022052015/602c3c29708a8a2b156eec7a/html5/thumbnails/2.jpg)
ITACA KC
WARM COMFORT
• Thermopolymer-coveredstainlesssteelheatexchanger
• Fullypre-mixedburner
• Modulatinggasvalvewithconstanair-to-gasratio
• Variable-speedcombustionfan
• Modulatingpumpwithair-purgingdevice
• 10-litreexpansionvessel
• Domestichotwaterstainlesssteelplateexchangerwiththermal
insulation
• Pre-setforconnectiontoaGSMmodemforremoteswitchingonand
off and malfunction alarm (optional equipment)
• Multifunctional relay for connection to systems with zone valves or to
solar systems or to remote boiler shutdown alarms
• InstallationflexibilitythankstoIPX5Delectricalprotectiondegree
• NOxemissionclass(EN297/EN483):5
• Sedbuk%(2009): KC24(nat.gas)=88.1-KC24(LPG)=89,1 KC28(nat.gas)=88.3-KC28(LPG)=89.3 KC32(nat.gas)=89.7-KC32(LPG)=91.3
Pre-set ready for connection to (optional accessories):
•externalprobe
•remotecontrol
•PCBsforlow-temperaturezones
ThEBOIlErPaCKaGEINCluDES:standardhydraulickit,template,air-intakeblankingplate,isolationvalveskit
Modulating pumpheatexchangerandpre-mixingburner
Model Fuel Code heatoutputkWSaP2009annual
efficiencySaP2005seasonal
efficiencyGross weight
(kg)
ITaCaKC24NaT.GaS CITI22Cr24
24.988.1 89.4
39LPG CITI26Cr24 89.1 90.5
ITaCaKC28NaT.GaS CITI22Cr28
27.988.3 89.5
40.5LPG CITI26Cr28 89.3 90.6
ITaCaKC32NaT.GaS CITI22Cr32
32.388.8 89.7
41.5LPG CITI26Cr32 89.8 91.3
![Page 3: WALL-HUNG CONDENSING COMBINATION BOILERS WITH ...tulips.bg/wp-content/uploads/2017/02/ctc_itaca_kc... · Electric protection rating IPX5D IPX5D IPX5D Gas fitting Ø G 1/2 G 1/2 G](https://reader034.vdocuments.mx/reader034/viewer/2022052015/602c3c29708a8a2b156eec7a/html5/thumbnails/3.jpg)
aCCESSOrIES
Article Description Code
Ø100/60mm,0.75metrecoaxialkit
0CONDaSP00
Ø100/60mmcoaxialkit 0KITaTCO00
90°elbowandflangekitØ60/100
0KCurFla00
SplitpipekitØ80+80 0KITSDOP00
Remote control 0CrEMOTO04
Externalprobe 0SONDaES01
Electriczonekitwithexternalprobe
0KITZONE05
Fixingtemplate(metal) 0DIMMECO11
Pipes and taps cover 0COPETuB03
GSMkitcompletewithantenna,powersupply,interfaceboard,modem
0KITMGSM00
Article Description Code
Cockfittedwithfilterandcheckvalve
0KITFIlT01
Solarconnectionkit(for combi boilers)
0KITSOlC07
Connectionkitforcomplexsolar systems
0KITSOlC08
Baxi/Itacareplacementkit 0KITSOST08
Beretta/Itacareplacementkit 0KITSOST09
Immergas/Itacareplacementkit
0KITSOST10
Vaillant/Itacareplacementkit 0KITSOST11
ariston/Itacareplacementkit 0KITSOST12
Tahiti/Itacareplacementkit 0KITSOST13
DIMENSIONSaNDCONNECTIONCENTrEDISTaNCES75
0 m
m
420 mm 315 mm76 60 62 67 82 73
63 92 190
39
100
124
3123
1012
1
750
420 315
76 60 62 67 82 73
63 92 190
39
100
124
3123
1012
1
750
420 315
76 60 62 67 82 73
63 92 190
39
100
124
3123
1012
1
G Gasinlet(1/2”)F Chflow(3/4”)DhW DhWoutlet(1/2”)
CWI Coldwaterinlet(1/2”)r Chreturn(3/4”)S Condensatedrain
S
FDHW
CWI
R
G
WARM COMFORT
Wall-huNGCONDENSINGCOMBINaTIONBOIlErSWIThPrE-MIXEDBurNEr
top view (sizes in mm)
bottom view (sizes in mm)
![Page 4: WALL-HUNG CONDENSING COMBINATION BOILERS WITH ...tulips.bg/wp-content/uploads/2017/02/ctc_itaca_kc... · Electric protection rating IPX5D IPX5D IPX5D Gas fitting Ø G 1/2 G 1/2 G](https://reader034.vdocuments.mx/reader034/viewer/2022052015/602c3c29708a8a2b156eec7a/html5/thumbnails/4.jpg)
TECHNICAL SPECIFICATIONS KC 24 KC 28 KC 32
Gas category II2H3P II2H3P II2H3P
Nominalheatinput kW 23.7 26.4 30.4
Nominalheatoutput(80-60°C) kW 22.9 25.4 29.4
Nominalheatoutput(50-30°C) kW 24.9 27.9 32.3
Minimumheatoutput(80-60°C) kW 2.7 3.0 3.9
Minimumheatoutput(50-30°C) kW 3.22 3.58 4.4
SaP2005seasonalefficiency NaT.GaS % 89.4 89.5 89.7
SaP2005seasonalefficiency LPG % 90.5 90.6 91.3
SaP2009annualefficiency NaT.GaS % 88.1 88.3 88.8
SaP2009annualefficiency LPG % 89.1 89.3 89.8
NOxemissionclass(EN297/EN483) 5 5 5
Chmaximumworkingpressure bar 3.0 3.0 3.0
Chmaximumworkingtemperature °C 83 83 83
CH temperature range °C 20-78 20-78 20-78
Expansionvesselcapacity l 10 10 10
Consumption at nominal heat input (CH) NaT.GaS m3/h 2.51 2.79 3.22
Consumption at minimum heat input (CH) NaT.GaS m3/h 0.32 0.35 0.44
Consumption at nominal heat input (CH) LPG kg/h 1.84 2.05 2.36
Consumption at minimum heat input (CH) LPG kg/h 0.23 0.26 0.33
DhWnominalheatoutput kW 27.4 29.2 33.4
DhWminimumheatoutput kW 3.0 3.0 3.9
DhWnominalheatinput kW 27.3 30.4 34.5
DhWminimum heat input kW 3.0 3.3 4.2
DhWmaximumpressure bar 6.0 6.0 6.0
DhWminimumpressure bar 0.5 0.5 0.5
DhWnominalflowrate(∆T35°C) l/min 11.5 13.3 13.9
Chmaximumworkingtemperature °C 62 62 62
DhWtemperaturerange °C 35-57 35-57 35-57
Consumptionatnominalheatinput(DhW) NaT.GaS m3/h 2.89 3.22 3.65
Consumptionatminimumheatinput(DhW) NaT.GaS m3/h 0.32 0.35 0.44
Consumptionatnominalheatinput(DhW) LPG kg/h 2.12 2.26 2.68
Consumptionatminimumheatinput(DhW) LPG kg/h 0.23 0.26 0.33
air-flueΔTatnominalheatinput(ChandDhW) °C 61 60 60
air-flueΔTatminimumheatinput °C 33 45 40.5
Fluegasflowatnominalheatinput(DhW) g/s 12.43 13.93 15.81
Fluegasflowatmin.heatinput g/s 1.33 1.47 1.87
CO2contentatPmax NaT.GaS % 9.0 9.0 9.0
CO2contentatPmax LPG % 10.0 10.0 10.0
Residual available head at nominal heat input Pa 130 170 183
Residual available head at minimum heat input Pa 1.56 2.0 3.5
Maxsupplypressure NaT.GaS mbar 20 20 20
Maxsupplypressure LPG mbar 37 37 37
Min supply pressure NaT.GaS mbar 3.0 3.0 3.0
Min supply pressure LPG mbar 8.0 8.0 8.0
Powersupplyvoltage/frequency V/hz 230/50 230/50 230/50
Fuse on the power supply A 3.15 3.15 3.15
Power absorption W 121 121 121
Electric protection rating IPX5D IPX5D IPX5D
Gas fitting Ø G1/2 G1/2 G1/2
CH fittings Ø G3/4 G3/4 G3/4
DhWfittings Ø G1/2 G1/2 G1/2
lxhxD mm 420x750x315 420x750x315 420x750x315
Boilernetweight kg 36.9 38.4 39.4
Boilergrossweight kg 39 40.5 41.5
The
man
ufac
ture
r res
erve
s th
e rig
ht to
impl
emen
t mod
ifica
tions
with
out n
otic
e.uff.Pub
b.Fon
ditalC
TC03C368-01aprile2013(3.000-04/2013)
9PC
GB
03C