vuil- en rioolwaterpompen-export...• raw and waste water • mixed water • raw and digested...

68
waste water and sewage pumps technical data dp pumps

Upload: others

Post on 17-Oct-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

waste water and sewage pumps

technical data

dp pumps

Page 2: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

Experience wateron a different level

In the Dutch market DP-Pumps has years ofexperience to build on when it comes towater management/ the transport of water inthe broadest sense of the word: we are justas skilful at treating wastewater as we are atboosting drinking water, the business weonce began with. Whether it concerns wastewater or sewage: we control the dynamics ofwater in both segments. That's why we arenow also offering our expertise on wastewater to our customers abroad.

Treatment of waste water, a serious taskA correct treatment of waste water is just asimportant as the treatment of drinking water.The variety of pumps and the numerousprojects in the Netherlands, prove that wetake the treatment of waste water very seri-ously. All of our pumps, irrespective of thetype, contribute to the simple, but most of allthe reliable control of waste water. Safetyand environment are special points of interest: all of our waste water and sewagepumps meet the highest safety and environ-mental requirements.

A world of possibilitiesWaste water is an extensive concept. That iswhy we offer you a wide delivery programwith pumps that are applicable in many sec-tors. DP-Pumps offers pumps for thedrainage of waste water in the industry or inthe domestic situation. The possibilities for the processing ofsewage are just as wide. Our sewage (sub-mersible) pumps with free-flow impeller, sin-gle-vane impeller, non-clogging impeller or

INDEXGeneral information 02Selection charts 04Pump characteristics 06Model identification 07DVV 3 / DVV 4 08DVV 7 10DVV 7 VD 12DVV 7 K 14DVV 10 16DVV 27 18DRV 6 20DRV 8 22DRV 9 24DRV 11 26DRV 12 28DRV 13 30DRV 24 32DRV 27 34DRSK 21 36DRSK 31 38DRS 3 40DRS 4 42DRS 6 44DRK 23 46DRK 41 48DRK 87 50DRK 107 52DRK 145 54DRK 178 56DRK 220 58DRK 250 60FEKA UNIT 62Accessories 64Notes 65

For every applicationThe right high tech solution

02

DP-Pumps is an ISO-9001 and ISO-14001 certified company.

Page 3: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

management

cutter are available in different designsand capacities. All of them guaranteeingthe high reliability DP-Pumps stands for.

Personal adviceOur area managers and technical advi-sors will be glad to assist you in manag-ing the dynamics of (waste) water. Pleasefeel free to contact us whenever you havequestions or need more informationregarding the possibilities of our products.

03

Page 4: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

SELECTION CHARTS

04

0

5

10

15

20

25

30

0 5 10 15 20 25 30 35 40Q(l/s)

H (m)

27

3 10

4

0 20 40 60 80 100 120 140

Q(m3/h)

7

11

0

5

10

15

20

25

30

0 5 10 15 20 25 30 35 40 45Q(l/s)

H (m)

8

69

12

0 20 40 60 80 100 120 140 160

Q(m3/h)

13

24

27

0

5

10

15

20

25

30

35

40

45

50

55

0 1 2 3 4 5 6 7Q(l/s)

H (m)

4

3

6

0 5 10 15 20 25

Q(m3/h)

DVV

DRV

DRS

Page 5: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

dp pumps www.dp-pumps.com05

0

5

10

15

20

25

30

35

40

45

0 25 50 75 100 125 150 175 200 225 250 275 300 325Q(l/s)

H (m)

23

0 100 200 300 400 500 600 700 800 900 1000 1100

Q(m3/h)

41

87 107

145 178

220

DRK

0 20 40 60 80 100 120 140 160 180 Q(m3/h)

31

21

0

2

4

6

8

10

12

14

16

0 5 10 15 20 25 30 35 40 45 50 55Q(l/s)

H (m) DRSK

Page 6: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

PUMP CHARACTERISTICS

06

V impellerFree flow impeller for fluids containing larger solid and longfibrous stringy material or coarsesolids, as well as fluids with entrapped air or gas.• Raw waste water• Activated sludge• Circulated and heating sludge• Raw and digested sludge• Mixed water

S impellerCutter for domestic sewage water containing fibrous stringy material.• Domestic waste water• Raw water • Faeces

K impellerSingle- vane impeller for wastewater containing solid and fibrousstringy material.• Raw and waste water• Mixed water• Raw and digested sludge• Activated sludge• Circulated and heating sludge

SK impellerNon-clogging impeller for wastewater containing solid and fibrousstringy material or coarse solids.• Raw and waste water• Mixed water• Raw and digested sludge• Activated sludge• Circulated and heating sludge

Page 7: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

dp pumps www.dp-pumps.com07

MODEL IDENTIFICATION

DVV 711-2WS D V V 7 11 - 2 W S

DRV 2426-4 165 E D R V 24 26 - 4 165 E

D: DP-Pumps

V: Waste water

R: Sewage water

V: Free-flow impeller

S: Cutter

K: Vane impeller

SK: Non-clogging impeller

Nominal capacityin l/sec.Motor rating (P2) in kW (kW *10 > 1,1=11)Motor size2-pole : 2850 min-1

4-pole : 1425 min-1

1~ motor

Level controlS: float switchA: automatic switch

(Intelligent Control System)

Impeller diameter[mm]

Special modelsO: oil resistantIN: industryK: cooling jacketE: flame proofHT: high temperatureVD: enlarged free

passage

Page 8: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DVV 3DVV 4

08

Special versions'IN' version for more abrasive water such as salty, swimming pool or brackish water• Motor housing Stainless Steel 1.4571 instead of Stainless Steel 1.4301• Motor shaft Stainless Steel 1.4571 instead of chrome steel• Medium temperature max. 40 °C in stead of 35 °C

Flange [PN] 2,5

Pump casing PP-H

Shaft seal pump

side

2x seal ring

Shaft seal motor

side

seal ring

Elastomer

components

NBR

Connect Voltage [V] 1 * 230

Motor Voltage [V] 1 * 230

IP 68

Insulation Class F

Thermal Motor

Monitoring

Clixon

Electric connection Cable+plug

Nom. speed [min-1] 2850

Temp. Max pumped

liquid [°C]

35

Pump type Connection

[G]/[DN]

Impeller Shaft P2

[kW]

Rated

current

[A]

Electric

cable

n x [mm2]

Length

electric

cable [m]

Free

passage

[mm]

h x w x d

[mm]

Pump

control

Weight

[kg]

32 W(S) 5/4 PP 1.4021 0,15 1,40 3 x 1 10 10 321 x 332 x 190 No 5

32 WS 5/4 PP 1.4021 0,15 1,40 3 x 0,75 3 10 321 x 332 x 190 Floatswitch

rod

4

34 W(S) 5/4 PPO 1.4021 0,40 3,60 3 x 1 10 10 375 x 332 x 190 No 7

34 WS 5/4 PPO 1.4021 0,40 3,60 3 x 0,75 3 10 375 x 332 x 190 Floatswitch

rod

6

34 WS VD 5/4 PP 1.4028 0,40 2,80 3 x 1 10 24 410 x 395 x 190 Floatswitch

rod

6,7

43 WS 6/4 PA 1.4028 0,30 2,80 3 x 1 10 35 420 x 395 x 285 Floatswitch

rod

7,1

44 WS 6/4 PA 1.4028 0,40 3,60 3 x 1 10 35 420 x 395 x 285 Floatswitch

rod

7,1

w

Page 9: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

dp pumps www.dp-pumps.com09

DVV 32DVV 34

capacity

head

capacity

head

DVV 3 2850 min-1 50Hz

DVV 34 VD & DVV 4 2850 min-1 50Hz

Page 10: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DVV 7

10

Connection [G]/[DN] 6/4

Flange [PN] 2,5

Pump Casing 1.4301

Impeller PA

Shaft 1.4021

Shaft seal pump side SiC/SiC

Shaft seal motor side seal ring

Elastomer components NBR

IP 68

Insulation Class F

Length electric

cable [m] 10

Nom. speed [min-1] 2850

Free passage [mm] 10

h x w x d [mm] 440 x 300 x 280

Temp. Max

pumped liquid [°C] 40

Pump type P2

[kW]

Rated

current

[A]

Connect

Voltage

[V]

Motor

Voltage

[V]

Thermal

Motor

Monitoring

Electric

cable

n x [mm2]

Electric

connection

Pump

control

Weight

[kg]

76 0,55 1,70 3 * 400 3 * 400 Bi-metal 6 x 1 Cable No 13,3

76 S 0,55 1,70 3 * 400 3 * 400 Bi-metal 6 x 1 Cable+plug Floatswitch 15,1

76 W 0,55 4,10 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug No 12,2

76 WS 0,55 4,10 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug Floatswitch 12,7

78 0,75 1,90 3 * 400 3 * 400 Bi-metal 6 x 1 Cable No 13,3

78 S 0,75 1,90 3 * 400 3 * 400 Bi-metal 6 x 1 Cable+plug Floatswitch 15,1

78 W 0,75 5,50 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug No 12,2

78 WS 0,75 5,50 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug Floatswitch 12,7

711 1,10 2,50 3 * 400 3 * 400 Bi-metal 6 x 1 Cable No 13,3

711 S 1,10 2,50 3 * 400 3 * 400 Bi-metal 6 x 1 Cable+plug Floatswitch 15,1

711 W 1,10 6,55 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug No 14,5

711 WS 1,10 6,55 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug Floatswitch 15

715 1,50 3,60 3 * 400 3 * 400 Bi-metal 6 x 1 Cable No 15,6

715 S 1,50 3,60 3 * 400 3 * 400 Bi-metal 6 x 1 Cable+plug Floatswitch 17,5

715 W 1,50 8,95 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug No 14,5

715 WS 1,50 8,95 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug Floatswitch 15

722 2,20 4,80 3 * 400 3 * 400 Bi-metal 6 x 1 Cable No 15,7

722 S 2,20 4,80 3 * 400 3 * 400 Bi-metal 6 x 1 Cable+plug Floatswitch 17,6

w

Page 11: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

dp pumps www.dp-pumps.com 11

0 50 100 150 200 220US.gpm

0 50 100 150 180IM.gpm

0 2 4 6 8 10 12 13.5l/s

0 10 20 30 40 50m /h3

20

40

60

80

5

10

15

20

25

1

DVV 722

DVV 715DVV 711DVV 78DVV 76

Hm

Hft

capacity

head

DVV 7 2850 min-1 50Hz

Page 12: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DVV 7 VD

12

Special version'IN' version with stainless steel 1.4401 instead of stainless steel 1.4301suitable for more abrasive water such as salty, swimming pool or brackishwater

Connection [G]/[DN] 6/4

Flange [PN] 2,5

Pump casing 1.4301

Impeller PA

Shaft 1.4021

Shaft seal pump side SiC/SiC

Shaft seal motor side seal ring

Elastomer components NBR

IP 68

Insulation Class F

Length electric cable [m] 10

Nom. speed [min-1] 2850

Free passage [mm] 35

h x w x d [mm] 500 x 300 x 280

Temp. Max pumped

liquid [°C]

40

Pump type P2

[kW]

Rated

current

[A]

Connect

Voltage

[V]

Motor

Voltage

[V]

Thermal

Motor

Monitoring

Electric

cable

n x [mm2]

Electric

connection

Pump

control

Weight

[kg]

76 VD 0,55 1,70 3 * 400 3 * 400 Bi-metal 6 x 1 Cable No 14,4

76 S VD 0,55 1,70 3 * 400 3 * 400 Bi-metal 6 x 1 Cable+plug Floatswitch 16,1

76 W VD 0,55 4,10 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug No 13,2

76 WS VD 0,55 4,10 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug Floatswitch 13,7

711 VD 1,10 2,50 3 * 400 3 * 400 Bi-metal 6 x 1 Cable No 14,4

711 S VD 1,10 2,50 3 * 400 3 * 400 Bi-metal 6 x 1 Cable+plug Floatswitch 16,1

711 W VD 1,10 6,55 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug No 15,5

711 WS VD 1,10 6,55 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug Floatswitch 16

722 VD 2,20 4,80 3 * 400 3 * 400 Bi-metal 6 x 1 Cable No 16,9

722 S VD 2,20 4,80 3 * 400 3 * 400 Bi-metal 6 x 1 Cable+plug Floatswitch 18,7

Page 13: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

dp pumps www.dp-pumps.com13

K2331:506/1

0 50 100 150US.gpm

0 20 40 60 80 100 120IM.gpm

0 2 4 6 8 10l/s

0 5 10 15 20 25 30 35m /h3

10

20

30

40

50

60

ft

2

4

6

8

10

12

14

16

18

20

1

21

m

DVV 76 VD

DVV 711 VD

DVV 722 VD

capacity

head

DVV 7 VD 2850 min-1 50Hz

Page 14: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DVV 7 K

14

Special versions'IN' version with stainless steel 1.4401 in stead of stainless steel 1.4301 suitable

for more abrasive water such as salty, swimming pool or brackish water'O' version suitable for pumping water containing oil. Elastomers in Viton.

Connection [G]/[DN] 2

Flange [PN] 2,5

Pump casing 1.4301

Impeller PA

Shaft 1.4021

Shaft seal pump side SiC/SiC

Shaft seal motor side seal ring

Elastomer

components

NBR

IP 68

Insulation Class F

Length electric cable

[m]

10

Nom. speed [min-1] 2850

Free passage [mm] 10

h x w x d [mm] 440 x 300 x 280

Temp. Max pumped

liquid [°C]

40

Pump type P2

[kW]

Rated

current

[A]

Connect

Voltage

[V]

Motor

Voltage

[V]

Thermal

Motor

Monitoring

Electric

cable

n x [mm2]

Electric

connection

Pump

control

Weight

[kg]

76 K 0,55 1,70 3 * 400 3 * 400 Bi-metal 6 x 1 Cable No 15,3

76 S K 0,55 1,70 3 * 400 3 * 400 Bi-metal 6 x 1 Cable+plug Floatswitch 17,1

76 W K 0,55 4,10 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug No 14,2

76 WS K 0,55 4,10 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug Floatswitch 14,7

78 K 0,75 1,90 3 * 400 3 * 400 Bi-metal 6 x 1 Cable No 15,3

78 S K 0,75 1,90 3 * 400 3 * 400 Bi-metal 6 x 1 Cable+plug Floatswitch 17,1

78 W K 0,75 5,50 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug No 14,2

78 WS K 0,75 5,50 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug Floatswitch 14,7

711 K 1,10 2,50 3 * 400 3 * 400 Bi-metal 6 x 1 Cable No 15,3

711 S K 1,10 2,50 3 * 400 3 * 400 Bi-metal 6 x 1 Cable+plug Floatswitch 17,1

711 W K 1,10 6,55 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug No 16,5

711 WS K 1,10 6,55 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug Floatswitch 17

715 K 1,50 3,60 3 * 400 3 * 400 Bi-metal 6 x 1 Cable No 17,6

715 S K 1,50 3,60 3 * 400 3 * 400 Bi-metal 6 x 1 Cable+plug Floatswitch 19,5

715 W K 1,50 8,95 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug No 16,5

715 WS K 1,50 8,95 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug Floatswitch 17

722 K 2,20 4,80 3 * 400 3 * 400 Bi-metal 6 x 1 Cable No 17,7

722 S K 2,20 4,80 3 * 400 3 * 400 Bi-metal 6 x 1 Cable+plug Floatswitch 19,6

Page 15: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

dp pumps www.dp-pumps.com15

0 50 100 150 200 220US.gpm

0 50 100 150 180IM.gpm

0 2 4 6 8 10 12 13.5l/s

0 10 20 30 40 50m /h3

20

40

60

80

5

10

15

20

25

1

DVV 722

DVV 715DVV 711DVV 78DVV 76

Hm

Hft

capacity

head

DVV 7 K 2850 min-1 50Hz

Page 16: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DVV 10

16

Connection [G]/[DN] 2

Flange [PN] 2,5

Pump casing JL 1040

Impeller PA

Shaft 1.4021

Shaft seal pump side SiC/SiC

Shaft seal motor side seal ring

Elastomer components NBR

P2 [kW] 2,20

Rated current [A] 4,80

Connect Voltage [V] 3 * 400

Motor Voltage [V] 3 * 400

IP 68

Insulation Class F

Thermal Motor

Monitoring

Bi-metal

Electric cable

n x [mm2]

6 x 1

Length electric

cable [m]

10

Nom. speed [min-1] 2850

Free passage [mm] 11

h x w x d [mm] 480 x 340 x 240

Temp. Max

pumped liquid [°C]

40

Pump type Electric connection Pump control Weight [kg]

1022 Cable No 22,5

1022 S Cable+plug Floatswitch 24,5

w

Page 17: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

dp pumps www.dp-pumps.com17

0 50 100 150 200 220US.gpm

0 50 100 150 180IM.gpm

0 2 4 6 8 10 12 13.5l/s

0 10 20 30 40 50m /h3

20

40

60

80

5

10

15

20

25

1

DVV 1022

Hm

Hft

capacity

head

DVV 10 2850 min-1 50Hz

Page 18: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DVV 27

18

Flange [PN] 16

Pump Casing GG

Impeller cast iron

Shaft 1.4021

Shaft seal pump side TuC/TuC

Shaft seal motor sid TuC/TuC

Elastomer components NBR

Connect Voltage [V] 3 * 400

IP 68

Isulation Class F

Thermal Motor

Monitoring

Bi-metal

Length electric

cable [m]

10

Nom. speed [min-1] 2850

Free passage [mm] 12

Temp. Max pumped

liquid [°C]

50

Pump type Connection

[G]/[DN]

P2

[kW]

Rated

current

[A]

Motor

Voltage

[V]

Electric

cable

n x [mm2]

Electric

connection

h x w x d

[mm]

Pump

control

Weight

[kg]

2740 80 4,00 8,50 3 * 400 7 x 1,5 Cable+plug 556 x 511 x 356 No 60,5

2740 S 80 4,00 8,50 3 * 400 7 x 1,5 Cable+plug 556 x 511 x 356 Floatswitch 61

2775 100 7,50 15,40 400/692 11 x 1,5 Cable 628 x 578 x 416 No 94,5

2775 S 100 7,50 15,40 400/692 11 x 1,5 Cable 628 x 578 x 416 Floatswitch 96

Special version'IN' version for liquids containing sand

Material pump casing: rubber-lined cast ironImpeller option: Norihard

w

Page 19: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

dp pumps www.dp-pumps.com19

IM.gpm

DVV 2775

DVV 2740

capacity

head

DVV 27 2850 min-1 50Hz

Page 20: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DRV 6

20

Connection [G]/[DN] 50

Flange [PN] 6

Pump Casing JL 1030

Impeller JL 1030

Shaft 1.4021

Shaft seal pump side SiC/Ce

Shaft seal motor side seal ring

Elastomer components NBR

IP 68

Isulation Class F

Length electric

cable [m]

10

Nom. speed [min-1] 2850

Temp. Max

pumped liquid [°C]

40

Weight [kg] 22

Pump type P2

[kW]

Rated

current

[A]

Connect

Voltage

[V]

Motor

Voltage

[V]

Thermal

Motor

Monitoring

Electric

cable

n x

[mm2]

Electric

connection

Impeller

diam.

[mm]

Free

passage

[mm]

h x w x d

[mm]

Pump control

66-2 100 0,55 5,00 3 * 400 3 * 400 ~ 4 x 1 Cable 100 45 396 x 318 x 198 No

66-2A 100 0,55 2,30 3 * 400 3 * 400 ~ 4 x 1 Cable 100 45 398 x 328 x 198 Autom

66-2W 100 0,55 5,00 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug 100 45 396 x 318 x 198 No

66-2WA 100 0,55 5,00 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug 100 45 398 x 328 x 198 Autom

66-2WS 100 0,55 5,00 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug 100 45 396 x 318 x 198 Floatswitch

68-2 110 0,75 2,80 3 * 400 3 * 400 ~ 4 x 1 Cable 110 45 396 x 318 x 198 No

68-2A 110 0,75 2,80 3 * 400 3 * 400 ~ 4 x 1 Cable 110 45 398 x 328 x 198 Autom

68-2W 110 0,75 6,00 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug 110 45 396 x 318 x 198 No

68-2WA 110 0,75 6,00 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug 110 45 398 x 328 x 198 Autom

68-2WS 110 0,75 6,00 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug 110 45 396 x 318 x 198 Floatswitch

611-2 120 1,10 3,00 3 * 400 3 * 400 ~ 4 x 1 Cable 120 43 396 x 318 x 198 No

611-2A 120 1,10 3,00 3 * 400 3 * 400 ~ 4 x 1 Cable 120 43 398 x 328 x 198 Autom

611-2W 120 1,10 8,20 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug 120 43 396 x 318 x 198 No

611-2W 130 1,10 8,20 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug 130 41 396 x 318 x 198 No

611-2WA 120 1,10 8,20 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug 120 43 398 x 328 x 198 Autom

611-2WA 130 1,10 8,20 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug 130 41 398 x 328 x 198 Autom

611-2WS 120 1,10 8,20 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug 120 43 396 x 318 x 198 Floatswitch

611-2WS 130 1,10 8,20 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug 130 41 396 x 318 x 198 Floatswitch

615-2 130 1,50 3,50 3 * 400 3 * 400 ~ 4 x 1 Cable 130 41 396 x 318 x 198 No

615-2A 130 1,50 3,50 3 * 400 3 * 400 ~ 4 x 1 Cable 130 41 398 x 328 x 198 Autom

w

Page 21: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

dp pumps www.dp-pumps.com21

130

120110

100

capacity

head

DRV 6 2850 min-1 50Hz

Page 22: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DRV 8

22

Connection [G]/[DN] 65

Flange [PN] 16

Pump Casing JL 1030

Impeller JL 1030

Shaft 1.4021

Shaft seal pump side SiC/Ce

Shaft seal motor side seal ring

Elastomer components NBR

IP 68

Isulation Class F

Length electric

cable [m]

10

Nom. speed [min-1] 2850

Temp. Max

pumped liquid [°C]

40

Weight [kg] 25

Pump type P2 [kW] Rated

current

[A]

Connect

Voltage

[V]

Motor

Voltage

[V]

Thermal

Motor

Monitoring

Electric

cable n x

[mm2]

Electric

connection

Impeller

diam.

[mm]

Free

passage

[mm]

h x w x d [mm] Pump control

88-2 110 0,75 2,80 3 * 400 3 * 400 ~ 4 x 1 Cable 110 60 410 x 364 x 224 No

88-2A 110 0,75 2,80 3 * 400 3 * 400 ~ 4 x 1 Cable 110 60 412 x 374 x 223 Autom

88-2W 110 0,75 6,00 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug 110 60 410 x 364 x 224 No

88-2WA 110 0,75 6,00 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug 110 60 412 x 374 x 223 Autom

88-2WS 110 0,75 6,00 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug 110 60 410 x 364 x 224 Floatswitch

811-2 120 1,10 3,00 3 * 400 3 * 400 ~ 4 x 1 Cable 120 58 410 x 364 x 224 No

811-2A 120 1,10 3,00 3 * 400 3 * 400 ~ 4 x 1 Cable 120 58 412 x 374 x 223 Autom

811-2W 120 1,10 8,20 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug 120 58 410 x 364 x 224 No

811-2W 130 1,10 8,20 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug 130 56 410 x 364 x 224 No

811-2WA 120 1,10 8,20 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug 120 58 412 x 374 x 223 Autom

811-2WA 130 1,10 8,20 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug 130 56 412 x 374 x 223 Autom

811-2WS 120 1,10 8,20 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug 120 58 410 x 364 x 224 Floatswitch

811-2WS 130 1,10 8,20 1 * 230 1 * 230 Clixon 3 x 1 Cable+plug 130 56 410 x 364 x 224 Floatswitch

815-2 130 1,50 3,50 3 * 400 3 * 400 ~ 4 x 1 Cable 130 56 410 x 364 x 224 No

815-2A 130 1,50 3,50 3 * 400 3 * 400 ~ 4 x 1 Cable 130 56 412 x 374 x 223 Autom

w

Page 23: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

dp pumps www.dp-pumps.com23

130120

110

capacity

head

DRV 8 2850 min-1 50Hz

Page 24: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DRV 9

24

Special versions"E" Explosion proof according to Eex d IIB T4"HT" High temperature version for temperatures up to max. 60 °C.

Connection [G]/[DN] 50

Flange [PN] 16

Pump Casing JL 1040

Impeller JL 1040

Shaft 1.4021

Shaft seal pump side SiC/SiC

Shaft seal motor side Ca/Ce

Elastomer components NBR

Connect Voltage [V] 3 * 400

Motor Voltage [V] 3 * 400

IP 68

Insulation Class F

Thermal Motor

Monitoring Bi-metal

Electric cable

n x [mm2] 7 x 1,5

Electric connection Cable

Length electric

cable [m] 10

Nom. speed [min-1] 2850

Free passage [mm] 40

h x w x d [mm] 470 x 322 x 250

Temp. Max

pumped liquid [°C] 55

Pump control No

Pump type P2 [kW] Rated current [A] Impeller diam. [mm] Weight [kg]

913-2 90 1,30 3,56 90 41

913-2 107 1,30 3,56 107 41

919-2 120 1,90 4,50 120 42

923-2 130 2,30 5,10 130 42

w

Page 25: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

dp pumps www.dp-pumps.com25

� �� ��� ��� ��� �������

� �� ��� ��� ��� ���

� � � � � �� �� �������

� �� �� �� �� ��� ���

� �� �� �� �� ��� ���

��

��

��

��

��

��

��

��

��

��

��

���

���

���

���

��

η [%]

���

��

��

��

��

��

��

���

��

����

��

��

��

��

��

��

����

����

��

���

����

��

��

��

��

��

��

����

����

��

��

���

���

����

����

��

��

��

��

��

����

����

��

��

���

capacity

head

DRV 9 2850 min-1 50Hz

Page 26: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DRV 11

26

Special versions"E" Explosion proof according to Eex d IIB T4"HT" High temperature version for temperatures up to max. 60 °C.

Connection [G]/[DN] 50

Flange [PN] 16

Pump casing JL 1040

Impeller JL 1040

Shaft 1.4021

Shaft seal pump side SiC/SiC

Shaft seal motor side Ca/Ce

Elastomer components NBR

Connect Voltage [V] 3 * 400

Motor Voltage [V] 3 * 400

IP 68

Insulation Class F

Thermal Motor

Monitoring Bi-metal

Electric cable

n x [mm2] 7 x 1,5

Electric connection Cable

Length electric

cable [m] 10

Nom. speed [min-1] 2850

Free passage [mm] 40

h x w x d [mm] 532 x 336 x 254

Temp. Max pumped

liquid [°C] 55

Pump control No

Pump type P2 [kW] Rated current [A] Impeller diam. [mm] Weight [kg]

1131-2 130 3,10 7,00 130 52

1131-2 140 3,10 7,00 140 52

1142-2 150 4,20 8,80 150 53

w

Page 27: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

dp pumps www.dp-pumps.com27

� �� ��� ��� ��� �������

� �� ��� ��� ��� ���

� � �� �����

� �� �� �� �� �� ��� ���

� �� �� �� �� �� ��� ���

��

��

��

��

���

���

��

��

��

��

��

��

��

��

��

���

��

η [%]

���

� �

��

��

� � ����

����

��

��

���

���

����

����

��

� ��������

��

��

���

���

����

��

��

� �

����������

����

����

���

capacity

head

DRV 11 2850 min-1 50Hz

Page 28: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

28

DRV 12

Special versions"E" Explosion proof according to Eex d IIB T4"HT" High temperature version for temperatures up to max. 60 °C.

Connection [G]/[DN] 65

Flange [PN] 16

Pump casing JL 1040

Impeller JL 1040

Shaft 1.4021

Shaft seal pump side SiC/SiC

Shaft seal motor side Ca/Ce

Elastomer components NBR

Connect Voltage [V] 3 * 400

Motor Voltage [V] 3 * 400

IP 68

Insulation Class F

Thermal Motor

Monitoring

Bi-metal

Electric cable

n x [mm2]

7 x 1,5

Electric connection Cable

Length electric

cable [m]

10

Nom. speed [min-1] 1450

Free passage [mm] 65

h x w x d [mm] 518 x 353 x 265

Temp. Max pumped

liquid [°C]

55

Pump control No

Pump type P2 [kW] Rated current [A] Impeller diam. [mm] Weight [kg]

128-4 112 0,80 2,75 112 49

128-4 125 0,80 2,75 125 49

128-4 135 0,80 2,75 135 49

128-4 145 0,80 2,75 145 49

128-4 155 0,80 2,75 155 49

1213-4 165 1,30 3,54 165 50

1213-4 175 1,30 3,54 175 50

1218-4 185 1,80 4,25 185 51

1218-4 195 1,80 4,25 195 51

w

Page 29: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

dp pumps www.dp-pumps.com29

0 100 200 300US.gpm

0 50 100 150 200 250IM.gpm

0 5 10 15 20l/s

0 10 20 30 40 50 60 70m /h3

0 10 20 30 40 50 60 70m /h30

10

20

30

ft

0

2

4

6

8

10

11

m

1

2

hp

0.5

1.0

1.5

0.1

1.7

kW

ø112

38

20

32

32

ø112

ø125

44.2

20

32

32

42

42

ø125

ø135

45.5

20

32

32

42

42

ø135

ø145

52.1

20

32

42

42

49

49

ø145

ø155

55

20

3242

42

49

49

53

53

ø155

ø165

56

2032

42

42

49

49

53

53

55.5

55.5

ø165

ø175

57.2

2032

42

42

49

49

53

53

55.5

55.5

ø175

ø185

56.7

202032

42

42

49

49

53

53

55.5

55.5

ø185

ø195

56

20203232

42

42

49

49

53

53

55.5

55.5

ø195

capacity

head

DRV 12 1450 min-1 50Hz

Page 30: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DRV 13

30

Special versions"E" Explosion proof according to Eex d IIB T4"HT" High temperature version for temperatures up to max. 60 °C.

Connection [G]/[DN] 65

Flange [PN] 16

Pump casing JL 1040

Impeller JL 1040

Shaft 1.4021

Shaft seal pump side SiC/SiC

Shaft seal motor side Ca/Ce

Elastomer components NBR

Connect Voltage [V] 3 * 400

Motor Voltage [V] 3 * 400

IP 68

Insulation Class F

Thermal Motor

Monitoring

Bi-metal

Electric cable

n x [mm2]

7 x 1,5

Electric connection Cable

Length electric

cable [m]

10

Nom. speed [min-1] 2850

Free passage [mm] 65

h x w x d [mm] 578 x 367 x 251

Temp. Max

pumped liquid [°C]

55

Pump control No

Pump type P2 [kW] Rated current [A] Impeller diam. [mm] Weight [kg]

1331-2 120 3,10 7,00 120 58

1331-2 128 3,10 7,00 128 58

1331-2 136 3,10 7,00 136 59

1342-2 146 4,20 8,80 146 59

1342-2 152 4,20 8,80 152 60

w

Page 31: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

dp pumps www.dp-pumps.com31

� ��� ��� ��� �������

� ��� ��� ��� ���

� � �� �� �� �����

� �� �� �� �� �� �� �� ��� ���

� �� �� �� �� �� �� �� ��� ���

��

��

��

��

��

��

��

��

��

���

��

η [%]

���

���

����

��

��

���

��

���

��

��

��

��

����

����

��

���

����

��

��

��

��

����

����

���

���

����

��

��

��

��

����

����

���

���

��

��

��

��

��

����

����

����

����

���

���

���

capacity

head

DRV 13 2850 min-1 50Hz

Page 32: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DRV 24

32

Special versions"E" Explosion proof according to Eex d IIB T4"HT" High temperature version for temperatures up to max. 60 °C.

Connection [G]/[DN] 80

Flange [PN] 16

Pump casing JL 1040

Impeller JL 1040

Shaft 1.4021

Shaft seal pump side SiC/SiC

Shaft seal motor side Ca/Ce

Elastomer components NBR

Connect Voltage [V] 3 * 400

Motor Voltage [V] 3 * 400

IP 68

Insulation Class F

Thermal Motor

Monitoring

Bi-metal

Electric cable

n x [mm2]

7 x 1,5

Electric connection Cable

Length electric

cable [m]

10

Nom. speed [min-1] 1450

Free passage [mm] 76

h x w x d [mm] 582 x 392 x 322

Temp. Max

pumped liquid [°C]

55

Pump control No

Pump type P2 [kW] Rated current [A] Impeller diam. [mm] Weight [kg]

2419-4 120 1,90 5,87 120 63

2419-4 135 1,90 5,87 135 63

2419-4 150 1,90 5,87 150 63

2426-4 165 2,60 6,50 165 64

2437-4 180 3,70 8,40 180 65

2437-4 195 3,70 8,40 195 65

w

Page 33: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

33dp pumps www.dp-pumps.com

0 200 400 600US.gpm

0 100 200 300 400 500IM.gpm

0 10 20 30l/s

0 20 40 60 80 100 120 140m /h3

0 20 40 60 80 100 120 140m /h30

10

20

30

40

ft

0

2

4

6

8

10

12

13.5

m

2

4

hp

1

2

3

0.2

3.8

kW

ø120

47

20

40

40

ø120

ø135

62

2040

40

50

50

58

58

ø135

ø150

62.6

2040

50

50

58

58

62

62

ø150

ø165

63

20

4050

50

58

58

62

62

ø165

ø180

63

20

40

50

50

58

58

62

62

ø180

ø195

62.4

20

40

50

50

58

58

62

62

ø195

capacity

head

DRV 24 1450 min-1 50Hz

Page 34: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DRV 27

34

Connection [G]/[DN] 100

Flange [PN] 16

Pump casing JL 1040

Impeller JL 1040

Shaft 1.4021

Shaft seal pump side SiC/SiC

Shaft seal motor side Ca/Ce

Elastomer components NBR

Motor Voltage [V] 3 * 400

IP 68

Insulation Class F

Thermal Motor

Monitoring

Bi-metal

Electric cable

n x [mm2]

7 x 1,5

Electric connection Cable

Length electric

cable [m]

10

Nom. speed [min-1] 1450

Free passage [mm] 100

h x w x d [mm] 603 x 383 x 318

Temp. Max

pumped liquid [°C]

55

Pump control No

Pump type P2 [kW] Rated current [A] Connect Voltage [V] Impeller diam. [mm] Weight [kg]

2719-4 120 1,90 5,87 3 * 400 120 64

2719-4 135 1,90 5,87 3 * 400 135 64

2726-4 150 2,60 6,50 3 * 400 150 64

2737-4 165 3,70 8,40 3 * 400 165 65

2737-4 180 3,70 8,40 3 * 400 180 66

2737-4 195 3,70 8,40 3 * 400 195 67

Special versions"E" Explosion proof according to Eex d IIB T4"HT" High temperature version for temperatures up to max. 60 °C.

w

Page 35: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

35dp pumps www.dp-pumps.com

0 200 400 600US.gpm

0 200 400 600IM.gpm

0 10 20 30 40l/s

0 20 40 60 80 100 120 140 160m /h3

0 20 40 60 80 100 120 140 160m /h30

10

20

30

ft

0

2

4

6

8

10

11.5

m

2

4

hp

1

2

3

0.4

3.8

kW

ø120

38.1

20

20

30

30

36

36

ø120

ø135

45.1

2030

30

36

36

41

41

ø135

ø150

49.3

2030

36

36

41

41

46

46

ø150

ø165

51.1

202030

36

36

41

41

46

46

50

50

ø165

ø180

54

2030

36

36

41

41

46

46

50

50

52.5

52.5

ø180

ø195

55.2

20

303636

41

41

46

46

50

50

52.5

52.5

55

55

ø195

capacity

head

DRV 27 1450 min-1 50Hz

Page 36: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DRSK 21

36

Connection [G]/[DN] 80

Flange [PN] 16

Pump casing JL 1040

Impeller JL 1040

Shaft 1.4021

Shaft seal pump side SiC/SiC

Shaft seal motor side Ca/Ce

Elastomer components NBR

P2 [kW] 1,90

Rated current [A] 5,87

Motor Voltage [V] 3 * 400

IP 68

Insulation Class F

Thermal Motor

Monitoring

Bi-metal

Electric cable

n x [mm2]

7 x 1,5

Electric connection Cable

Length electric

cable [m]

10

Nom. speed [min-1] 1450

Free passage [mm] 65

h x w x d [mm] 602 x 392 x 322

Temp. Max

pumped liquid [°C]

55

Pump control No

Pump type Connect Voltage [V] Impeller diam. [mm] Weight [kg]

2119-4 154 3 * 400 154 74

2119-4 168 3 * 400 168 74

2119-4 180 3 * 400 180 74

2119-4 190 3 * 400 190 75

w

Special versions"E" Explosion proof according to Eex d IIB T4"HT" High temperature version for temperatures up to max. 60 °C.

Page 37: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

37dp pumps www.dp-pumps.com

0 200 400 600US.gpm

0 100 200 300 400 500IM.gpm

0 10 20 30l/s

0 20 40 60 80 100 120 140m /h3

0 20 40 60 80 100 120 140m /h30

10

20

30

40

ft

0

2

4

6

8

10

12

13

m

1

2

hp

0.5

1.0

1.5

2.0

kW

Qmin

ø154

44

32

32

43

43

ø154

ø168

56

32

32

43

43

50

50

ø168

ø180

61.8

3232

43

43

50

50

57

57

61

61

ø180

ø190

69.1

32

43

43

50

50

57

57

61

61

66

66

68.5

68.5

ø190

capacity

head

DRSK 21 1450 min-1 50Hz

Page 38: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DRSK 31

38

Connection [G]/[DN] 100

Flange [PN] 16

Pump casing JL 1040

Impeller JL 1040

Shaft 1.4021

Shaft seal pump side SiC/SiC

Shaft seal motor side Ca/Ce

Elastomer components NBR

Connect Voltage [V] 3 * 400

Motor Voltage [V] 3 * 400

IP 68

Insulation Class F

Thermal Motor

Monitoring

Bi-metal

Electric cable

n x [mm2]

7 x 1,5

Electric connection Cable

Length electric

cable [m]

10

Nom. speed [min-1] 1450

Free passage [mm] 76

h x w x d [mm] 628 x 383 x 318

Temp. Max

pumped liquid [°C]

55

Pump control No

Pump type P2 [kW] Rated current [A] Impeller diam. [mm] Weight [kg]

3126-4 195 2,60 6,50 195 79

3137-4 209 3,70 8,40 209 79

3137-4 220 3,70 8,40 220 80

w

Special versions"E" Explosion proof according to Eex d IIB T4"HT" High temperature version for temperatures up to max. 60 °C.

Page 39: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

39dp pumps www.dp-pumps.com

0 200 400 600 800US.gpm

0 200 400 600IM.gpm

0 10 20 30 40 50l/s

0 20 40 60 80 100 120 140 160 180 200m /h3

0 20 40 60 80 100 120 140 160 180 200m /h3

10

20

30

40

50

ft

2

4

6

8

10

12

14

16

1

m

2

4

hp

2

3

1.4

3.6

kW

Qmin

ø195

61.2

53

53

57

57

60

60

ø195

ø209

68.4

53

53

57

57

60

60

64

64

67.5

67.5

ø209

ø220

71

53

53

57

57

60

60

64

64

67.5

67.5

70

70

ø220

capacity

head

DRSK 31 1450 min-1 50Hz

Page 40: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DRS 3

40

Connection [G]/[DN] 50

Flange [PN] 6

Pump casing JL 1030

Impeller JL 1030

Shaft 1.4021

Shaft seal pump side SiC/SiC

Shaft seal motor side seal ring

Elastomer components NBR

IP 68

Insulation Class F

Electric cable n x

[mm2]

4 x 1

Length electric cable

[m]

10

Nom. speed [min-1] 2850

Impeller diam. [mm] 145

Free passage [mm] 7

Temp. Max pumped

liquid [°C]

40

Pump type P2

[kW]

Rated

current

[A]

Connect

Voltage

[V]

Motor

Voltage

[V]

Thermal

Motor

Monitoring

Electric

connection

h x w x d [mm] Pump control Weight

[kg]

311-2W 145 1,10 8,20 1 * 230 1 * 230 Clixon Cable+plug 396 x 318 x 198 No 26

311-2WA 145 1,10 8,20 1 * 230 1 * 230 Clixon Cable+plug 396 x 328 x 198 Autom 26

311-2WS 145 1,10 8,20 1 * 230 1 * 230 Clixon Cable+plug 396 x 318 x 198 Floatswitch 26

315-2 145 1,50 3,50 3 * 400 3 * 400 ~ Cable 396 x 318 x 198 No 24

315-2A 145 1,50 3,50 3 * 400 3 * 400 ~ Cable 396 x 328 x 198 Autom 24

w

Page 41: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

41dp pumps www.dp-pumps.com

head

head

Ø 145

Ø 145

DRS 3 2850 min-1 50Hz 1*230V

DRS 3 2850 min-1 50Hz 3*400V

capacity

capacity

Page 42: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DRS 4

42

Special versions'E' Explosion proof according to Eex d IIB T4'HT' High temperature version for temperatures up to max. 60 °C

Connection [G]/[DN] 50

Flange [PN] 16

Pump casing JL 1040

Impeller JL 1040

Shaft 1.4021

Shaft seal pump side SiC/SiC

Shaft seal motor side Ca/Ce

Elastomer components NBR

Connect Voltage [V] 3 * 400

Motor Voltage [V] 3 * 400

IP 68

Insulation Class F

Thermal Motor

Monitoring

Bi-metal

Electric cable n x [mm2] 7 x 1,5

Electric connection Cable

Length electric cable [m] 10

Nom. speed [min-1] 2850

Free passage [mm] 6

h x w x d [mm] 470 x 322 x 250

Temp. Max pumped

liquid [°C]

55

Pump control No

Weight [kg] 39

Pump type P2 [kW] Rated current [A] Impeller diam. [mm]

413-2 120 1,30 3,56 120

413-2 140 1,30 3,56 140

419-2 160 1,90 4,50 160

w

Page 43: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

43dp pumps www.dp-pumps.com

capacity

head

DRS 4 2850 min-1 50Hz

Page 44: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DRS 6

44

Special versions'E' Explosion proof according to Eex d IIB T4'HT' High temperature version for temperatures up to max. 60 °C

Connection [G]/[DN] 50

Flange [PN] 16

Pump casing JL 1040

Impeller JL 1040

Shaft 1.4021

Shaft seal pump side SiC/SiC

Shaft seal motor side Ca/Ce

Elastomer

components

NBR

Connect Voltage [V] 3 * 400

Motor Voltage [V] 3 * 400

IP 68

Insulation Class F

Thermal Motor

Monitoring

Bi-metal

Electric cable n x

[mm2]

7 x 1,5

Electric connection Cable

Length electric cable

[m]

10

Nom. speed [min-1] 2850

Free passage [mm] 6

h x w x d [mm] 532 x 336 x 254

Temp. Max pumped

liquid [°C]

55

Pump control No

Weight [kg] 54

Pump type P2 [kW] Rated current [A] Impeller diam. [mm]

631-2 175 3,10 7,00 175

642-2 190 4,20 8,80 190

w

Page 45: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

45dp pumps www.dp-pumps.com

nput

capacity

head

DRS 6 2850 min-1 50Hz

Page 46: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DRK 23

46

Connection [G]/[DN] 80

Pump casing JL 1040

Impeller JL 1040

Shaft 1.4021

Shaft seal pump side SiC/SiC

Shaft seal motor side Ca/SiC

Elastomer components NBR

P2 [kW] 8,50

Rated current [A] 16,70

Connect Voltage [V] 3 * 400

Motor Voltage [V] 400/692

IP 68

Insulation Class F

Thermal Motor

Monitoring

Bi-metal

Electric cable

n x [mm2]

12*1,5

Electric connection Cable

Length electric

cable [m]

10

Nom. speed [min-1] 2905

Free passage [mm] 42

h x w x d [mm] 610 x 470 x 355

Temp. Max

pumped liquid [°C]

40

Pump control No

Weight [kg] 151

Pump type Impeller diam. [mm]

2385-2 182 182

2385-2 196 196

w

Page 47: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

47dp pumps www.dp-pumps.com

0 200 400 600US.gpm

0 100 200 300 400 500IM.gpm

0 10 20 30 40l/s

0 20 40 60 80 100 120 140m /h3

0 20 40 60 80 100 120 140m /h30

50

100

150

ft

0

10

20

30

40

48

m

8

10

12

hp

6

8

4.5

9

kW

ø182

56.7

40

40

50

50

55

55

ø182

ø196

59.9

40

40

50

50

55

55

58

58

ø196

Qmin

capacity

head

DRK 23 50Hz

Page 48: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DRK 41

48

Connection [G]/[DN] 100

Flange [PN]

Pump casing JL 1040

Impeller JL 1040

Shaft 1.4021

Shaft seal pump side SiC/SiC

Shaft seal motor side Ca/SiC

Elastomer

components

NBR

Connect Voltage [V] 3 * 400

Motor Voltage [V] 400/692

IP 68

Isulation Class F

Thermal Motor

Monitoring

Bi-metal

Electric cable n x

[mm2]

12*1,5

Electric connection Cable

Length electric cable

[m]

10

Free passage [mm] 90

h x w x d [mm] 600 x 475 x 388

Temp. Max pumped

liquid [°C]

40

Pump control No

Pump type P2 [kW] Rated current [A] Nom. speed [min-1] Impeller diam. [mm] Weight [kg]

4155-4 202 5,50 12,10 1430 202 141

4155-4 220 5,50 12,10 1430 220 141

4175-4 245 7,50 15,80 1440 245 155

w

Page 49: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

49dp pumps www.dp-pumps.com

0 200 400 600 800 950US.gpm

0 200 400 600 800IM.gpm

0 20 40 60l/s

0 20 40 60 80 100 120 160 180 200 220m /h3

0 20 40 60 80 100 120 160 180 200 220m /h3

20

40

60

ft

5

10

15

20

3

23

m

5

10

hp

2

4

6

8

kW

ø202

61.9

5055

55

60

60

ø202

ø220

70.3

5055

6060

65

68

68

70

70

ø220

ø245

76.9

6065

6870

75

75

ø245

Qmin

capacity

head

DRK 41 50Hz

Page 50: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DRK 87

50

Connection [G]/[DN] 150

Pump Casing JL 1040

Impeller JL 1040

Shaft 1.4021

Shaft seal pump side SiC/SiC

Shaft seal motor side Ca/SiC

Elastomer components NBR

Connect Voltage [V] 3 * 400

Motor Voltage [V] 400/692

IP 68

Isulation Class F

Thermal Motor Monitoring Bi-metal

Electric connection Cable

Length electric cable [m] 10

Free passage [mm] 110

Temp. Max pumped liquid [°C] 40

Pump control No

Pump type P2 [kW] Rated

current

[A]

Electric

cable

n x [mm2]

Nom.

speed

[min-1]

Impeller

diam.

[mm]

h x w x d [mm] Weight

[kg]

87118-4 254 11,80 23,50 12*1,5 1465 254 740 x 640 x 535 146

87160-4 275 16,00 33,00 7*4+5*1,5 1465 275 740 x 640 x 535 256

87210-4 295 21,00 40,50 7*4+5*1,5 1435 295 880 x 640 x 535 325

87270-4 305 27,00 55,00 7*6+5*1,5 1455 305 850 x 640 x 535 343

w

Page 51: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

51dp pumps www.dp-pumps.com

0 500 1000 1500 2000 2400US.gpm

0 500 1000 1500 2000IM.gpm

0 50 100 150l/s

0 100 200 300 400 500 560m /h3

0 100 200 300 400 500 560m /h3

50

100

ft

10

20

30

2

36

m

20

10

hp

10

20

4

26

kW

ø254

72.5

60

60

65

65

70

70

ø254

ø275

74.2

65

65

70

70

ø275

ø295

75.7

60

60

65

65

70

70

75

75

ø295

ø305

77.3

60

60

65

65

70

70

75

75

ø305

Qmin

60

capacity

head

DRK 87 50Hz

Page 52: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DRK 107

52

Connection [G]/[DN] 150

Pump casing JL 1040

Impeller JL 1040

Shaft 1.4021

Shaft seal pump side SiC / SiC

Shaft seal motor side Ca/SiC

Elastomer

components

NBR

Connect Voltage [V] 3 * 400

Motor Voltage [V] 400/692

IP 68

Insulation Class F

Thermal Motor

Monitoring

Bi-metal

Electric connection Cable

Length electric cable

[m]

10

Free passage [mm] 76

Temp. Max pumped

liquid [°C]

40

Pump control No

Pump type P2

[kW]

Rated

current

[A]

Electric

cable

n x [mm2]

Nom.

speed

[min-1]

Impeller

diam.

[mm]

h x b x d [mm] Weight

[kg]

107118-4 235 11,80 23,50 12*1,5 1465 235 740 x 640 x 535 146

107118-4 250 11,80 23,50 12*1,5 1465 250 740 x 640 x 535 146

107160-4 265 16,00 33,00 7*4+5*1,5 1465 265 740 x 640 x 535 256

107210-4 280 21,00 40,50 7*4+5*1,5 1435 280 880 x 640 x 535 325

107270-4 295 27,00 55,00 7*6+5*1,5 1455 295 850 x 640 x 535 343

w

Page 53: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

53dp pumps www.dp-pumps.com

0 500 1000 1500 2000 2500 2700US.gpm

0 500 1000 1500 2000 2200IM.gpm

0 50 100 150 170l/s

0 100 200 300 400 500 600m /h3

0 100 200 300 400 500 600m /h3

50

100

ft

10

20

30

2

36

m

20

40

hp

10

20

30

2

kW

ø235

71

55 6065

65

70

70

ø235

ø250

74.9

5555 6065

65

70

70

ø250

ø265

78.1

5555 606065

65

70

70

75

75

7878

ø265

ø280

79.5

55 6065

65

70

70

75

75

78

78

ø280

ø295

80.9

55 6065

65

70

70

75

75

78

78

80

ø295

Qmin

capacity

head

DRK 107 50Hz

Page 54: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DRK 145

54

Connection [G]/[DN] 200

Pump casing JL 1040

Impeller JL 1040

Shaft 1.4021

Shaft seal pump side SiC/SiC

Shaft seal motor side Ca/SiC

Elastomer

components

NBR

Connect Voltage [V] 3 * 400

Motor Voltage [V] 400/692

IP 68

Insulation Class F

Thermal Motor

Monitoring

Bi-metal

Electric connection Cable

Length electric cable

[m]

10

Free passage [mm] 121

Pump control No

Pump type P2 [kW] Rated

current

[A]

Electric

cable

n x [mm2]

Nom.

speed

[min-1]

Impeller

diam.

[mm]

h x w x d [mm] Temp.

Max

pumped

liquid [°C]

Weight

[kg]

145130-6 319 13,00 27,50 7*4+5*1,5 965 319 1045 x 840 x 640 60 480

145130-6 351 13,00 27,50 7*4+5*1,5 965 351 1045 x 840 x 640 60 480

145180-6 373 18,00 35,50 7*4+5*1,5 955 373 1045 x 840 x 640 40 480

145240-6 400 24,00 47,00 7*6+5*1,5 960 400 1020 x 840 x 640 40 505

w

Page 55: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

55dp pumps www.dp-pumps.com

0 1000 2000 3000US.gpm

0 500 1000 1500 2000 2500IM.gpm

0 50 100 150 200l/s

0 100 200 300 400 500 600 700m /h3

0 100 200 300 400 500 600 700m /h3

20

40

60

80

ft

5

10

15

20

25

2

27

m

10

20

30

hp

5

10

15

20

25

kW

Qmin

67.2

5555

6060

65

65

68.9

55

6060

65

65

68

68

69.2

55

6060

6565

68

68

70.2

5555

60

6565

68

68

70

70

Ø319

Ø319

Ø351

Ø351

Ø373

Ø373

Ø400

Ø400

capacity

head

DRK 145 50Hz

Page 56: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DRK 178

56

Connection [G]/[DN] 250

Pump casing JL 1040

Impeller JL 1040

Shaft 1.4021

Shaft seal pump side SiC/SiC

Shaft seal motor side Ca/SiC

Elastomer

components

NBR

Connect Voltage [V] 3 * 400

Motor Voltage [V] 400/692

IP 68

Insulation Class F

Thermal Motor

Monitoring

Bi-metal

Electric connection Cable

Length electric cable

[m]

10

Free passage [mm] 85

Pump control No

Pump type P2

[kW]

Rated

current

[A]

Electric

cable

n x [mm2]

Nom.

speed

[min-1]

Impeller

diam.

[mm]

h x b x d

[mm]

Temp.

Max

pumped

liquid [°C]

Weight

[kg]

178130-6 300 13,00 27,50 7*4+5*1,5 965 300 970 x 990 x 735 60 555

178180-6 318 18,00 35,50 7*4+5*1,5 955 318 970 x 990 x 735 40 555

178240-6 340 24,00 47,00 7*6+5*1,5 960 340 945 x 990 x 735 40 580

178300-6 370 30,00 64,00 2*4*6+12*1,5 975 370 1105 x 990 x 735 40 710

w

Page 57: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

57dp pumps www.dp-pumps.com

K41815/2

0 1000 2000 3000 4000 5000US.gpm

0 1000 2000 3000 4000IM.gpm

0 100 200 300l/s

0 200 400 600 800 1000 1200m /h3

0 200 400 600 800 1000 1200m /h30

20

40

60

ft

0

5

10

15

20

24

m

20

30

40

hp

10

15

20

25

30

8

kW

Qmin

69.8

50

50

60

60

68

68

75.2

50

50

60

60

68

68

74

74

79

50

50

60

60

68

68

74

74

78

78

82.1

50

50

60

60

68

68

74

74

78

78

81.5

81.5

Ø300/290

Ø300/290

Ø318/310

Ø318/310

Ø340

Ø340

Ø370

Ø370

capacity

head

DRK 178 50Hz

Page 58: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DRK 220

58

Connection [G]/[DN] 300

Pump casing JL 1040

Impeller JL 1040

Shaft 1.4021

Shaft seal pump side SiC/SiC

Shaft seal motor side Ca/SiC

Elastomer

components

NBR

Connect Voltage [V] 3 * 400

Motor Voltage [V] 400/692

IP 68

Insulation Class F

Thermal Motor

Monitoring

Bi-metal

Electric cable n x

[mm2]

12*1,5

Electric connection Cable

Length electric cable

[m]

10

Free passage [mm] 135

h x w x d [mm] 1060 x 1050 x 850

Pump control No

Pump type P2

[kW]

Rated

current

[A]

Electric

cable

n x [mm2]

Nom.

speed

[min-1]

Impeller

diam.

[mm]

Temp. Max

pumped liquid

[°C]

Weight

[kg]

22070-8 367 7,00 16,50 12*1,5 725 367 60 735

220100-8 384 10,00 22,50 12*1,5 715 384 40 735

220160-8 398 16,00 36,00 7*4+5*1,5 730 398 40 755

220160-8 408 16,00 36,00 7*4+5*1,5 730 408 40 755

w

Page 59: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

59dp pumps www.dp-pumps.com

0 1000 2000 3000 4000 5000US.gpm

0 1000 2000 3000 4000IM.gpm

0 100 200 300l/s

0 200 400 600 800 1000m /h3

0 200 400 600 800 1000m /h3

10

20

30

ft

2

4

6

8

9.5

m

5

10

15

20

hp

5

10

15

3

17

kW

Qmin

69.2

505060

65

74.8

506060

656570

70

77.9

5060

657070

75

75

80.7

505060

6570

75

75

78

78

80

80

ø367/331

ø367/331

ø384/350

ø384/350

ø398/371

ø398/371

ø408/393

ø408/393

DRK 220 50Hz

capacity

head

Page 60: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

DRK 250

60

Connection [G]/[DN] 300

Pump casing JL 1040

Impeller JL 1040

Shaft 1.4021

Shaft seal pump side SiC/SiC

Shaft seal motor side Ca/SiC

Elastomer

components

NBR

Connect Voltage [V] 3 * 400

Motor Voltage [V] 400/692

IP 68

Insulation Class F

Thermal Motor

Monitoring

Bi-metal

Electric connection Cable

Length electric cable

[m]

10

Free passage [mm] 100

Temp. Max pumped

liquid [°C]

40

Pump control No

Pump type P2

[kW]

Rated

current

[A]

Electric

cable

n x [mm2]

Nom.

speed

[min-1]

Impeller

diam.

[mm]

h x w x d

[mm]

Weight

[kg]

250100-8 332 10,00 22,50 12*1,5 715 332 1060 x 1050 x 850 735

250160-8 355 16,00 36,00 7*4+5*1,5 730 355 1060 x 1050 x 850 755

250160-8 376 16,00 36,00 7*4+5*1,5 730 376 1060 x 1050 x 850 755

250200-8 390 20,00 44,00 7*6+5*1,5 705 390 1035 x 1050 x 850 775

250280-8 408 28,00 60,00 15 730 408 1200 x 1050 x 850 900

w

Page 61: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

61dp pumps www.dp-pumps.com

0 2000 4000 6000US.gpm

0 1000 2000 3000 4000 5000IM.gpm

0 100 200 300 400l/s

0 200 400 600 800 1000 1200 1400m /h3

0 200 400 600 800 1000 1200 1400m /h3

10

20

30

40

50

ft

2

4

6

8

10

12

14

0.5

15.5

m

10

20

30

hp

5

10

15

20

25

kW

Qmin

78.7

5060

60

68

68

74

74

81.7

5060

60

68

68

74

74

80

80

82.9

5060

68

68

74

74

80

80

84.1

50

60

68

68

74

74

80

80

83

83

84.2

50

60

68

68

74

74

80

80

83

83

[%]

ø332/300

ø332/300

ø355/330

ø355/330

ø376/358

ø376/358

ø390/384

ø390/384

ø408

ø408

DRK 250 50Hz

capacity

head

Page 62: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

FEKA-UNIT C

62

ApplicationAutomatic transport of domestic waste andsewage water

Capacity50 m3/h

Head8 mwc

Temperature rangeUp to 35 °C continuously, 65 °C temporarily(5 minutes)

ReservoirSynthetic material LLPDEC1 (1 pump) :90 ltr. Gross C2 (2 pumps) :150 ltr. Gross Discharge connection DN 80

ControlAutomatic level control by built-in float switch

Easy connectionThe suction connection height of the Feka-UnitC is fit to the standard toilet connection; the unitcan be installed at the same level as the con-nected toilet.

Other models• 2 pumps (C2)• other materials for more aggressive liquids• equipped with cutter for smaller discharge

connections • other voltages and frequencies

Page 63: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

dp pumps www.dp-pumps.com63

POS. NR. NAME

1 Level control

2 Synthetic reservoir

3 Venting DN 70

4 Discharge connection NW80

5 Incoming drain connection DN50

6 Pump

7 Incoming drain connection DN100/150

8 Incoming drain connection DN100for direct toilet connection

9 Inspection lid

Page 64: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

ACCESSORIES

64

DP MT 30 Hydrostatic transmitter for optimum level controlDP-Pumps pressure transmitters are designedfor level control in tanks, reservoirs, poldersand containers in which submerged pressuretransmitters are required. The working principleis based on measuring the hydrostatic pressurecaused by the height of the fluid level. Theceramic measuring cell is built in a stainlesssteel housing.

Stainless steel couplingsAs a consequence of our expertise in stainlesssteel in clean water, we have developed arange of discharge couplings for application insewage stations. Stainless steel is strong, hard-wearing and extremely resistant to H2S.Depending on the application and require-ments, two types of couplings can be used.Both are suitable for various pump types andbrands.

Header couplingThis stainless steel coupling is placed abovethe water surface. The pump hangs on to thecoupling. This way, by lifting the pump, thesewage station is easy to inspect and clean. A continuous flow of the medium is guaranteed,as there are no obstacles on the reservoir bot-tom.

Guide bar couplingThis stainless steel coupling is placed on thebottom of the reservoir. This makes the installa-tion of larger and heavier pumps possible.When pump inspection is required, the pumpalone can be lifted. The special construction ofthe duckfoot guarantees a continuous flow ofthe medium.

Please feel free to contact DP-Pumps for moreinformation on the products on this page.

DP MT 30

Header coupling

Guide bar coupling

Page 65: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

NOTES

dp pumps www.dp-pumps.com65

Page 66: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

NOTES

66

The data published in thisdocument can be subject tochange. DP-Pumps reservesthe right to make modificationswithout prior notice.

Page 67: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

NOTES

dp pumps www.dp-pumps.com67

Page 68: vuil- en rioolwaterpompen-export...• Raw and waste water • Mixed water • Raw and digested sludge • Activated sludge • Circulated and heating sludge dp pumps 07 MODEL IDENTIFICATION

dp pumps

dp pumpsP.O. Box 282400 AA Alphen aan den RijnHolland

t +31 172 48 83 25f +31 172 46 89 30

[email protected]

97004429-1105