vrf v5x series 50hz - kencarkencar.net/wp-content/uploads/2017/06/eu-v5-x-series … · ·...
TRANSCRIPT
Commercial Air Conditioners 2017/2018
VRF V5X Series50Hz
iOS Version Android Version
Midea CAC After-service Application
iOS Version
Midea CAC News Application
Add.: Midea Headquarters Building, 6 Midea Avenue, Shunde, Foshan, Guangdong, China
Postal code: 528311
Tel: +86-757-26338346 Fax: +86-757-22390205
cac.midea.com global.midea.com
Note: Product speci�cations change from time to time as product improvements and
developments are released and may vary from those in this document.
Commercial Air Conditioner Division
Midea Group
1702-1V1702-EU
There are three production bases: Shunde, Chongqing and Hefei.
MCAC Shunde: 38 product lines focusing on VRF, Split Products, Heat Pump Water Heaters, and AHU/FCU.
MCAC Chongqing: 14 product lines focusing on Water Cooled Centrifugal/Screw/Scroll Chillers, Air Cooled
Screw/Scroll Chillers, and AHU/FCU.
MCAC Hefei: 11 product lines focusing on VRF, Chillers, and Heat Pump Water Heaters.
Midea CACMidea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider
of heating, ventilation and air conditioning solutions. Midea CAC has continued with the tradition of
innovation upon which it was founded, and emerged as a global leader in the HVAC industry. A strong
drive for advancement has created a groundbreaking R&D department that has placed Midea CAC at the
forefront of a competitive field. Through these independent efforts and joint cooperation with other
global enterprises, Midea has supplied thousands of innovative solutions to customers worldwide.
Midea Company Introduction
Midea CAC Introduction
2016
2014-2015
2014
2011-2014
2011-2012
2009
2008
2000-2001
1999
Acquired 80% stake in Clivet
Win FIFA World Cup Stadiums project in Brazil Beira Rio, Olympic Games Stadiums project in Brazil Rio de
Janeiro and Africa games Stadiums project in Congo Brazzaville successively
Launched the All DC Inverter V5X globally, outstanding product performance helps Midea leading VRF
market
Launched the DC Inverter V4 Plus Series successively, complete product lines help Midea successfully enter
the mainstream VRF market
J.V. with Carrier LA and Carrier India successively
Launched the DC Inverter V4 globally
Developed DC inverter technology with Toshiba
Cooperated with Toshiba and Copeland, enter VRF field
03 04
Technology Inspires Possibilities
HP 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88
OUTDOOR UNIT LINEUP
Single unit
Multi combination
05 06
Technology Inspires Possibilities
OUTDOOR UNITSVRF V5 X SYSTEM
High E�ciency
Wide Application Range
High Reliability
Enhanced Comfort
Easy Installation and Service
V5X Introduction
07 08
Technology Inspires Possibilities
EER
8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP
4.70
4.504.30 4.30
4.10 3.90 3.86 3.74
COP
5.605.30
4.904.80
4.60
4.254.12 4.03
8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP
Low
High
15-step vector control
Gas
Gas
Gas
Liquid
Liquid
Liquid
Gas LiquidGas-Liquid
Original design
New design
43°C
75°C 75°C
37°C
δ design
75°C
37°C
High E�ciencyHigh EER and COP
DC compressors and fan motors together with a high-efficiency heat exchanger combine to give
the V5 X Series top-class energy efficiency in cooling and heating.
High E�ciency Heat ExchangerNewly designed fins enlarge the heat exchange area and decrease air resistance,
enhance heat exchange performance and save more energy.
Hydrophilic fins and internally threaded copper pipes optimize heat exchange
efficiency.
δ design increases the degree of liquefaction in the condenser and improves
heat-exchange efficiency.
Newly Designed FanA new blade with sharp edges and a slight curve increases the airflow rate and lowers vibration and airflow resistance.
Precise Control Multiple solenoid valves ensure precise temperature control, stable and efficient operation, and improved comfort.
Dual EXVs ControlDual EXVs in one system, each EXV part achieves 480 Pulse rate to
precisely adjust refrigerant flow.
All DC Inverter CompressorsAt the heart o f the V5 X Ser ies outdoor uni t l ies a
wor ld- lead ing DC inver ter sc ro l l compressor . The
compressor's innovative design and numerous high
performance features reduce power consumption by 25%.
All DC Fan MotorsFan speed is controlled according to the system pressure and system load, minimizing energy consumption.
New structure enhancesmid-frequency performance
Advanced permanentmagnet DC motor improves low
frequency band performance
More compact, weightreduced by 50%
Specially designedscroll profile for R410A
09 10
Technology Inspires Possibilities
Leve
l diff
eren
ce b
etw
een
IDU
~ID
U 3
0m
90mLo
nges
t act
ual p
ipin
g le
ngth
175
m
Leve
l diff
eren
ce b
etw
een
IDU
~O
DU
110
m
1st stage
2nd stage
3rd stage
4th stage
5th stage
48°C
-5°C
24°C
-20°C
COOLING MODE
HEATING MODE-20°C
-10°C
0°C
10°C
20°C
30°C
40°C
50°C
1 2 3 4 1 2 34 3 4 1 2 2 3 4 1
Wide Capacity RangeThe V5 X series has an extensive range of
capacities, from 8HP to 88HP, meeting all
customer requirements from small to large
buildings.
Wide Range of Indoor UnitsMidea provides 12 types and more than 100 models of VRF
indoor units to meet varied customer requirements in a wide
range of locations including shopping malls, hospitals, office
buildings, hotels and airports.
Wide Operation RangeV5X Series operates stably under extreme
conditions, ranging from minus 20°C to 48°C. BackupIn a multi-unit system, if one module fails, the other modules
provide backup so that the system can continue operating.
Precise Oil Control TechnologyFive stages of oil control technology ensure all outdoor compressor oil is always kept at a safe level, eliminating any compressor
oil shortage problems.
Duty CyclingDuty cycling equalizes the running time of the outdoor units in a multiple-unit system and of the compressors in each unit,
significantly extending compressor lifespan.
Long Piping Capability
Wide Application Range
*The longest length after first branch is 40m as standard but can be extended to up to 90m under certain conditions. Please contact your local Midea dealer for further information.
Total piping length
Piping length Capability
1000m
175m (200m)
90m*
90m (110m)
30m
Longest length - actual (equivalent)
Longest length after first branch
Largest height difference between indoor and outdoor units - ODU up (down)
Largest height difference between indoor units
High Reliability
The 1st stage:
The 2nd stage:
The 3rd stage:
The 4th stage:
The 5th stage:
Compressor internal oil separation.
High-efficiency centrifugal oil separator (with separation efficiency of up to 99%) ensures that oil is
separated from the discharge gas and returned to the compressors in a timely fashion.
Oil balance pipes between compressors ensure even oil distribution to keep compressors running normally.
Oil balance pipes among modules ensure even oil distribution among modules.
Auto oil return program monitors the running time and system status to ensure reliable oil return.
11 12
Technology Inspires Possibilities
Hea
ting
capa
city
Usual defrosting
∆t
Time
t min
Intelligent defrosting
2
Fluctuation of room temperature
Cooling operation
1
Temp
Inverter Non-Inverter
Time
P Q EX Y E X Y E P Q E P Q E P Q E P Q E
Outside Inside
15 dB(A) reduction
Quiet
1
2
3
4
5
6
7
8
910
Max. 150o
Night Silent ModeThe night silent mode feature, which is easily configured on the outdoor unit's PBC, includes various scheduling options that
can be used to reduce noise levels at times when low noise operation is required.
Simple Communication WiringIndoor centralized controller can be connected to either the indoor or the outdoor units.
A single set of wiring can be used for system and network communication, making installation quicker and easier.
Rotatable Electric Control BoxThe newly designed rotating control box can be rotated up to 150 degrees to provide access to the pipeline system for
inspection and maintenance without the need to remove the control box.
Intelligent Defrosting TechnologyThe intelligent defrosting program calculates the
time required for defrosting according to the actual
sys tem status , e l iminat ing heat losses f rom
unnecessary defrosting. A specialized defrosting
valve reduces time required for defrosting to as little
at four minutes.
Auto AddressingOutdoor unit can distribute addresses to indoor
units automatically.
Remote and wired controllers can be used to
query or modify each indoor unit's address.
Easy MaintainenceSpecial features that increase ease of maintenance include a control box
inspection window for viewing the system status, a self-diagnosis function
that speeds fault analysis, and the positioning of the compressor adjacent to
the casing, which simplifies inspection and enables valve or compressor parts
to be replaced easily.
Rapid Cooling or HeatingThe DC inverter compressor reaches full capacity
rapidly, providing quicker cooling or heating with
lower levels of temperature fluctuation during the
cooling/heating operation.
Enhanced Comfort Easy Installation and Service
MotorStandard products:
72h of neutral salt mist
Heavy anti-corrosion products:
240h of neutral salt mist
Heat Exchanger Aluminum FoilStandard products:
72h of neutral salt mist
Heavy anti-corrosion products:
1000h of neutral salt mist
140h of acid salt mist
Electric Control Box CaseStandard products:
96h of neutral salt mist
Heavy anti-corrosion products:
240h of neutral salt mist
Compressor / Motor BoltsStandard products:
72h of neutral salt mist
Heavy anti-corrosion products:
168h of neutral salt mist
CopperStandard products:
24h of neutral salt mist
Heavy anti-corrosion products:
120h of neutral salt mist
Screws / Bolts / GasketsStandard products:
300h of neutral salt mist
Heavy anti-corrosion products:
720h of neutral salt mist
Painted Sheet MetalStandard products:
500h of neutral salt mist
1000h of moisture and heating test
500h of light aging test
Heavy anti-corrosion products:
1000h of neutral salt mist
2000h of moisture and heating test
720h of light aging test
13 14
Technology Inspires Possibilities
Anti-corrosion Protection
Outside
Outdoor units are given anti-corrosion treatment for non-extreme conditions as standard and can also be customized with heavy
anti-corrosion treatment on steel sheets, grills, coil fins, electric control box case and screws/bolts for surface protection against
corrosive air, acid rain and saline air (for installations in coastal regions) to extend overall useful life.
The integrity of the anti-corrosion treatment is ensured by subjecting major components and parts to salt mist testing, moisture
and heating testing and light aging testing.
15 16
Technology Inspires Possibilities
Speci�cations Speci�cations
Notes:Capacities are based on the following conditions:Cooling: Indoor temperature 27oC DB/19oC WB; Outdoor temperature 35oC DB/24oC WB; Heating: Indoor temperature 20oC DB/15oC WB; Outdoor temperature 7oC DB/6oC WB.Piping length: Interconnecting piping length is 7.5m, level difference is zero.Connection piping diameter of single-unit is the stop valve diameter of the unit. Connection piping diameter of multi-unit is the main pipe connecting to the first indoor branch joint, is case of the total equivalent liquid length is less than 90m. If the total equivalent liquid length is more than 90m, please refer to technical manual to choose the connection piping diameter.Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.
Notes:Capacities are based on the following conditions:Cooling: Indoor temperature 27oC DB/19oC WB; Outdoor temperature 35oC DB/24oC WB; Heating: Indoor temperature 20oC DB/15oC WB; Outdoor temperature 7oC DB/6oC WB.Piping length: Interconnecting piping length is 7.5m, level difference is zero.Connection piping diameter of single-unit is the stop valve diameter of the unit. Connection piping diameter of multi-unit is the main pipe connecting to the first indoor branch joint, is case of the total equivalent liquid length is less than 90m. If the total equivalent liquid length is more than 90m, please refer to technical manual to choose the connection piping diameter.Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.
380-415/3/50
50~130% of outdoor unit capacity
DC inverter
DC motor
20 (default)60 (customized)
R410A
HPModelPower supplyCooling
Heating
Connectable indoor unitCompressor
Fan motor
Refrigerant
Pipeconnections
Air flow rateSound pressure levelSound power levelNet dimensions (W×H×D)Packed dimensions (W×H×D) Net weightGross weight
CapacityPower inputEERESEERCapacityPower inputCOPTotal capacityMax. quantityTypeQuantityTypeQuantityMax Static Pressure
TypeFactory chargingTCO2eqLiquid pipeGas pipe
V/Ph/HzkWkW
kWkW
PaPa
kgtonmmmmmmm3/hdB(A)dB(A)mmmmkgkg
8MV5-X252W/V2GN1
25.2 5.36 4.70 8.2527.0 4.82 5.60
13
1
1
918.79Φ12.7
1200058
10MV5-X280W/V2GN1
28.0 6.22 4.50 7.9031.5 5.94 5.30
16
1
1
918.79Φ12.7
120005971
990×1635×7901055×1805×855
219
12MV5-X335W/V2GN1
33.5 7.79 4.30 7.5437.5 7.65 4.90
20
1
1
1122.97Φ15.9
1200060
237
14MV5-X400W/V2GN1
40.0 9.30 4.30 7.5445.0 9.38 4.80
23
2
2
1327.14Φ15.9
140006274
1340×1635×7901405×1805×855
297
Operating temperature range
Oil balance pipe
°C234 252 315
70
Φ25.4 Φ25.4 Φ28.6
219
72
Cooling: -5-48; Heating: -20-24
Φ6.35
380-415/3/50
50~130% of outdoor unit capacity
DC inverter2
DC motor2
20 (default)60 (customized)
R410A
1340×1635×790
HPModelPower supplyCooling
Heating
Connectable indoor unitCompressor
Fan motor
Refrigerant
Pipeconnections
Air flow rateSound pressure levelSound power levelNet dimensions (W×H×D)Packed dimensions (W×H×D) Net weightGross weight
CapacityPower inputEERESEERCapacityPower inputCOPTotal capacityMax. quantityTypeQuantityTypeQuantityMax Static Pressure
TypeFactory chargingTCO2eqLiquid pipeGas balance pipe
V/Ph/HzkWkW
kWkW
PaPa
kgtonmmmmmmm3/hdB(A)dB(A)mmmmkgkg
16MV5-X450W/V2GN1
45.0 10.98 4.10 7.2050.0
10.87 4.60
26
1327.14Φ15.9
1400062
297
18MV5-X500W/V2GN1
50.0 12.82 3.90 7.3656.0
13.18 4.25
29
1327.14Φ19.1
1600063
305
20MV5-X560W/V2GN1
56.0 14.51 3.86 7.2863.0
15.29 4.12
33
1633.41Φ19.1
1600063
340
22MV5-X615W/V2GN1
61.5 16.44 3.74 7.0469.0
17.12 4.03
36
1633.41Φ19.1
1600063
340
Operating temperature range
Oil balance pipe
°C Cooling: -5-48; Heating: -20-24315 323 358 358
1405×1805×855
74
Φ6.35Φ31.8Φ31.8Φ31.8Φ31.8
HPModelCombined typePower supplyCooling
Heating
Connectable indoor unitCompressor
Fan motor
Refrigerant
Pipeconnections
Air flow rateSound pressure levelSound power levelNet dimensions (W×H×D)Packed dimensions (W×H×D) Net weightGross weight
CapacityPower inputEERESEERCapacityPower inputCOPTotal capacityMax. quantityTypeQuantityTypeQuantityTypeFactory chargingTCO2eqLiquid pipeGas pipe
V/Ph/HzkWkW
kWkW
kgtonmmmmm3/hm3/hdB(A)dB(A)mmmmkgkg
380-415/3/50
50~130% of outdoor unit capacity
DC inverter
DC motor
R410A
24MV5-X670W/V2GN1
12HP×2
67.0 15.58 4.30 7.5475.0
15.31 4.90
39
2
2
11×222.97×2
Φ15.9
24000 6476
(990×1635×790)×2(1055×1805×855)×2
237×2
26MV5-X730W/V2GN1
10HP+16HP
73.0 17.20 4.24 7.4781.5
16.81 4.85
43
3
3
9+1318.79+27.14
Φ19.1
26000
65
219+297
28MV5-X780W/V2GN1
10HP+18HP
78.0 19.04 4.10 7.5087.5
19.12 4.58
46
3
3
9+1318.79+27.14
Φ19.1
28000
65
219+305
30MV5-X840W/V2GN1
10HP+20HP
84.0 20.73 4.05 7.5294.5
21.23 4.45
50
3
3
9+1618.79+33.41
Φ19.1
28000
65
1055×1805×855+1405×1805×855
219+340
32MV5-X895W/V2GN1
10HP+22HP
89.5 22.67 3.95 7.42
100.523.06 4.36
53
3
3
9+1618.79+33.41
Φ19.1
2800065
219+340
34MV5-X950W/V2GN1
12HP+22HP
95.0 24.23 3.92 7.38
106.524.77 4.30
56
3
3
11+1618.79+33.41
Φ19.1
2800065
237+340
Cooling: -5-48; Heating: -20-24252×2 234+315 234+323 234+358 234+358 252+358
1055×1805×855+1405×1805×855
Operating temperature range °C
Oil balance pipe
7777777777
Φ6.35Φ31.8Φ31.8Φ31.8Φ31.8Φ31.8Φ28.6
HPModelCombined typePower supplyCooling
Heating
Connectable indoor unitCompressor
Fan motor
Refrigerant
Pipeconnections
Air flow rateSound pressure levelSound power levelNet dimensions (W×H×D)Packed dimensions (W×H×D) Net weightGross weight
CapacityPower inputEERESEERCapacityPower inputCOPTotal capacityMax. quantityTypeQuantityTypeQuantityTypeFactory chargingTCO2eqLiquid pipeGas pipe
V/Ph/HzkWkW
kWkW
kgtonmmmmmmm3/hdB(A)dB(A)mmmmkgkg
380-415/3/50
50~130% of outdoor unit capacity
DC inverter4
DC motor4
R410A
Φ19.1Φ38.1
66
36MV5-X1000W/V2GN1
18HP×2
100.0 25.64 3.90 7.36
112.0 26.35 4.25
59
13×2
305×2
38MV5-X1065W/V2GN1
16HP+22HP
106.5 27.42 3.88 7.32
119.0 27.99 4.25
63
13+16
315+358
40MV5-X1115W/V2GN1
18HP+22HP
111.5 29.26 3.81 7.10
125.0 30.30 4.13
64
13+16
(1340×1635×790)×2
305+340
42MV5-X1175W/V2GN1
20HP+22HP
117.5 30.95 3.80 7.08
132.0 32.41 4.07
64
16×2
340×2
44MV5-X1230W/V2GN1
22HP×2
123.0 32.89 3.74 7.04
138.0 34.24 4.03
64
16×2
340×2340×2
46MV5-X1285W/V2GN1
12HP×2+22HP
128.532.03 4.01 7.49
144.0 32.43 4.44
64
11×2+16
((990×1635×790)×2+1340×1635×790
(1055×1805×855)×2+1405×1805×855
237×2+340
Operating temperature range
Oil balance pipe
°C Cooling: -5-48; Heating: -20-24252×2+358358×2358×2323+358315+358323×2
(1405×1805×855)×2
78
32000 30000 32000 32000 32000 40000Φ6.35
27.14×2 27.14+33.41 27.14+33.41 33.41×2 33.41×2 22.97×2+33.41
234
Φ31.8
75 75 75
Speci�cations Speci�cations
17 18
Technology Inspires Possibilities
Notes:Capacities are based on the following conditions:Cooling: Indoor temperature 27oC DB/19oC WB; Outdoor temperature 35oC DB/24oC WB; Heating: Indoor temperature 20oC DB/15oC WB; Outdoor temperature 7oC DB/6oC WB.Piping length: Interconnecting piping length is 7.5m, level difference is zero.Connection piping diameter of single-unit is the stop valve diameter of the unit. Connection piping diameter of multi-unit is the main pipe connecting to the first indoor branch joint, is case of the total equivalent liquid length is less than 90m. If the total equivalent liquid length is more than 90m, please refer to technical manual to choose the connection piping diameter.Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.
Notes:Capacities are based on the following conditions:Cooling: Indoor temperature 27oC DB/19oC WB; Outdoor temperature 35oC DB/24oC WB; Heating: Indoor temperature 20oC DB/15oC WB; Outdoor temperature 7oC DB/6oC WB.Piping length: Interconnecting piping length is 7.5m, level difference is zero.Connection piping diameter of single-unit is the stop valve diameter of the unit. Connection piping diameter of multi-unit is the main pipe connecting to the first indoor branch joint, is case of the total equivalent liquid length is less than 90m. If the total equivalent liquid length is more than 90m, please refer to technical manual to choose the connection piping diameter.Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.
HPModelCombined typePower supplyCooling
Heating
Connectable indoor unitCompressor
Fan motor
Refrigerant
Pipeconnections
Air flow rateSound pressure levelSound power levelNet dimensions (W×H×D)Packed dimensions (W×H×D) Net weightGross weight
CapacityPower inputEERESEERCapacityPower inputCOPTotal capacityMax. quantityTypeQuantityTypeQuantityTypeFactory chargingTCO2eqLiquid pipeGas pipe
V/Ph/HzkWkW
kWkW
kgtonmmmmmmm3/hdB(A)dB(A)mmmmkgkg
48MV5-X1345W/V2GN1
10HP+16HP+22HP
134.5 33.64 4.00 7.48
150.5 33.93 4.44
9+13+1618.79+27.14+33.41
Φ19.1
219+297+340
50MV5-X1395W/V2GN1
10HP+18HP+22HP
139.5 35.49 3.93 7.40
156.5 36.24 4.32
9+13+1618.79+27.14+33.41
Φ19.1
219+305+340
52MV5-X1455W/V2GN1
10HP+20HP+22HP380-415/3/50
145.5 37.17 3.91 7.37
163.5 38.36 4.26
50~130% of outdoor unit capacity64
DC inverter5
DC motor5
R410A9+16×2
18.79+33.41×2Φ22.2Φ41.3Φ6.35 44000
6779
990×1635×790+(1340×1635×790)×21055×1805×855+(1405×1805×855)×2
219+340×2
54MV5-X1510W/V2GN1
10HP+22HP×2
151.0 39.11 3.86 7.28
169.5 40.19 4.22
9+16×218.79+33.41×2
Φ22.2
219+340×2
56MV5-X1565W/V2GN1
12HP+22HP×2
156.540.68 3.85 7.18
175.541.90 4.19
11+16×222.97+33.41×2
Φ22.2
237+340×2
Cooling: -5-48; Heating: -20-24Operating temperature range
Oil balance pipe
°C252+358×2234+358×2234+358×2234+323+358234+315+358
44000440004400042000
Φ38.1 Φ38.1 Φ41.3
HPModelCombined typePower supplyCooling
Heating
Connectable indoor unitCompressor
Fan motor
Refrigerant
Pipeconnections
Air flow rateSound pressure levelSound power levelNet dimensions (W×H×D)Packed dimensions (W×H×D) Net weightGross weight
CapacityPower inputEERESEERCapacityPower inputCOPTotal capacityMax. quantityTypeQuantityTypeQuantityTypeFactory chargingTCO2eqLiquid pipeGas pipe
V/Ph/HzkWkW
kWkW
kgtonmmmmmmm3/hdB(A)dB(A)mmmmkgkg
70MV5-X1960W/V2GN110HP+16HP+22HP×2
196.0 50.09 3.91 7.37
219.5 51.06 4.30
9+13+16×2
219+297+340×2
72MV5-X2010W/V2GN110HP+18HP+22HP×2
201.0 51.93 3.87 7.30
225.5 53.36 4.23
9+13+16×2
219+305+340×2
74MV5-X2070W/V2GN110HP+20HP+22HP×2
380-415/3/50207.0 53.62 3.86 7.28
232.5 55.48 4.19
50~130% of outdoor unit capacity64
DC inverter7
DC motor7
R410A9+16×3
18.79+33.41×3Φ25.4Φ44.5
Φ6.35 60000
6981
(990×1635×790)+(1340×1635×790)×3(1055×1805×855)+(1405×1805×855)×3
219+340×3
76MV5-X2125W/V2GN1
10HP+22HP×3
212.5 55.55 3.83 7.12
238.5 57.31 4.16
9+16×3
219+340×3
78MV5-X2180W/V2GN1
12HP+22HP×3
218.0 57.12 3.82 7.11
244.559.02 4.14
11+16×3
237+340×3237+340×3
Cooling: -5-48; Heating: -20-24234+358×3 252+358×3234+358×3234+323+358×2234+315+358×2
Oil balance pipe
°C
600006000060000 58000
18.79+27.14+33.41×2 18.79+27.14+33.41×2 18.79+33.41×3 22.97+33.41×3
HPModelCombined typePower supplyCooling
Heating
Connectable indoor unitCompressor
Fan motor
Refrigerant
Pipeconnections
Air flow rateSound pressure levelSound power levelNet dimensions (W×H×D)Packed dimensions (W×H×D) Net weightGross weight
CapacityPower inputEERESEERCapacityPower inputCOPTotal capacityMax. quantityTypeQuantityTypeQuantityTypeFactory chargingTCO2eqLiquid pipeGas pipe
V/Ph/HzkWkW
kWkW
kgtonmmmmmmm3/hdB(A)dB(A)mmmmkgkg
80MV5-X2230W/V2GN1
18HP×2+22HP×2
223.0 58.53 3.81 7.10
250.0 60.60 4.13
13×2+16×2
305×2+340×2
82MV5-X2295W/V2GN1
16HP+22HP×3
229.5 60.31 3.81 7.10
257.0 62.23 4.13
13+16×3
297+340×3
84MV5-X2345W/V2GN1
18HP+22HP×3380-415/3/50
234.5 62.15 3.77 7.05
263.0 64.54 4.07
50~130% of outdoor unit capacity64
DC inverter8
DC motor8
R410A13+16×3
27.14+33.41×3Φ25.4Φ44.5
Φ6.35 64000
7082
(1340×1635×790)×4(1405×1805×855)×4
305+340×3323+358×3
86MV5-X2405W/V2GN1
20HP+22HP×3
240.5 63.84 3.77 7.05
270.0 66.66 4.05
16×4
340×4
88MV5-X2460W/V2GN1
22HP×4
246.0 65.78 3.74 7.04
276.0 68.49 4.03
16×4
340×4
Operating temperature range
Oil balance pipe
°C Cooling: -5-48; Heating: -20-24358×4 358×4315+358×3323×2+358×2
62000 64000 64000
HPModelCombined typePower supplyCooling
Heating
Connectable indoor unitCompressor
Fan motor
Refrigerant
Pipeconnections
Air flow rateSound pressure levelSound power levelNet dimensions (W×H×D)Packed dimensions (W×H×D)Net weightGross weight
CapacityPower inputEERESEERCapacityPower inputCOPTotal capacityMax. quantityTypeQuantityTypeQuantityTypeFactory chargingTCO2eqLiquid pipeGas pipe
V/Ph/HzkWkW
kWkW
kgtonmmmmmmm3/hdB(A)dB(A)mmmmkgkg
380-415/3/50
50~130% of outdoor unit capacity64
DC inverter6
DC motor6
R410A
68
58MV5-X1615W/V2GN1
18HP×2+22HP
161.5 42.08 3.84 7.13
181.0 43.47 4.16
13×2+1627.14×2+33.41
Φ22.2
305×2+340
60MV5-X1680W/V2GN1
16HP+22HP×2
168.0 43.86 3.83 7.12
188.0 45.11 4.17
13+16×227.14+33.41×2
Φ22.2
297+340×2
62MV5-X1730W/V2GN1
18HP+22HP×2
173.0 45.71 3.78 7.06
194.0 47.42 4.09
13+16×227.14+33.41×2
Φ22.2
(1340×1635×790)×3(1405×1805×855)×3
305+340×2
64MV5-X1790W/V2GN1
20HP+22HP×2
179.0 47.40 3.78 7.06
201.0 49.53 4.06
16×333.41×3
Φ22.2
340×3
66MV5-X1845W/V2GN1
22HP×3
184.549.33 3.74 7.04
207.0 51.36 4.03
16×333.41×3
Φ22.2
340×3
68MV5-X1900W/V2GN1
12HP×2+22HP×2
190.0 48.47 3.92 7.38
213.0 46.13 4.62
11×2+16×222.97×2+33.41×2
Φ25.4
(990×1635×790)×2+(1340×1635×790)×2
(1055×1805×855)×2+(1405×1805×855)×2
237×2+340×2
Φ41.3
Operating temperature range
Oil balance pipe
°C Cooling: -5-48; Heating: -20-24323×2+358 315+358×2 323+358×2 358×3 358×3 252×2+358×2
80
560004800048000480004600048000Φ6.35
Φ41.3 Φ41.3 Φ41.3 Φ41.3 Φ41.3 Φ44.5
Operating temperature range
64000
27.14×2+33.41×2 27.14+33.41×3 33.41×4 33.41×4