DOMESTIC VENTILATION
Vortice® providescomfort indoors.Air pollution in the home iscaused by the presence ofpeople and their activities.In order to safeguard ourhealth, rooms must beproperly ventilated toimprove the quality of the airwe breathe.Vortice® offers a wide rangeof products that are speciallydesigned to achieve thisobjective. These productsstar t with the Vortice® Puntorange of axial fans, whichoffers a comprehensive rangeof options for wall, ceiling(with ducting up to 4m long)and window extraction.Centrifugal extractor fans areavailable to meet the needswhen axial fans areunacceptable. These includethe standard type (Vort)which is used to ventilatethrough ducting, theprofessional centrifugal type,which includes like the Ariettand Vort Press® for eitherflush or wall mounting. TheVMC Ariant central extractsystem provides continuousventilation. Finally, Vorticeoffers 18 Cooker hoodmodels and under hood fansto suit the décor of anykitchen.
00.PUNTO DEF 30-06-2003 16:20 Pagina 16
19
A B C D ∅ E
M 100/4” 159 160 100 47 99
M 120/5” 179 181 110 47 119
M 150/6” 214 215 117 47 156
B ∅ E
A
D
C
➀ ➂➁
➃
18
m3/h
l/s 0
mmH2OPa
40
30
20
10
0
p
10 20
5
4
3
2
1
00 8040
qv
120 200
30 40 50
160m3/h
l /s 0
mmH2OPa
30
20
10
0
p
t
10 20
4
3
2
1
00 5025
qv
75 100
qv
l/s 0
mmH2OPa
60
40
20
0
p t
8
6
4
2
00 200100 300 400
30 60 90
m3/h
100 120 150
230-240 20 0.12 2100 175 48.6 4.5 44 39.5 0.8 cl.II X4 50
230-240 30 0.15 2100 335 93.1 6 59 46 1.1 cl.II X4 50
m3 /
h
mm
H2O
Pa
l/s
AV ~ 50 Hz WLp dB(A)
3 m kg IP °Cmax
M 100/4”
M 120/5”
M 150/6”
230-240 18 0.1 2300 90 25 3 29 37.5 0.6 cl.II X4 50
P max
VORTICE® PUNTO RANGE
■ For intermittent orcontinuous ventilation ofbathrooms, toilets, kitchensor utility rooms in domesticor commercial properties.
■ 82 models available with orwithout the option of automaticshutters, timer, pull cord,humidistat, electronicmicroprocessor and Passiveinfrared.
■ Motor with sheilded poles, eitherwith bronze or ball bearings, andwith thermal cut-out.
■ The standard models can bespeed regulated.
SPLASHPROOF AXIAL EXTRACT FANS USED TO EXTRACT AIR EITHERDIRECTLY TO THE OUTSIDE OR INTO DUCTING UP TO 4m LONG
■ IMQ data label ensures data andperformance is third partycertified.
■ High airflow rate, low operatingnoise level and low powerconsumption due to the wingprofile blades and motor support.
■ IPX4 splashproof protection onall models.
■ Motor support and grille made ofanti-UV ABS.
■ Available in three outlet sizes:∅ 100, 120 and 150 mm.
■ Conforms to the followingstandards: EN 60335-2-80 (Part 2:Particular requirements for fans),EN 60529 (Code IP) and CEI 107-53/1986.
Design: F. Trabucco & Associates
Accessories(description and data on page 23)
Wiring diagrams shown on page XXVII.
Dimensions (mm)
➀ Installation showing extract directly to the outside.➁ Ceiling installation on up to 4m duct.➂ Through the wall installation with wall sleeve and grille.➃ Window installation with standard window kit.
SPLASHPROOF AXIAL EXTRACT FANS USED TO EXTRACT AIR EITHERDIRECTLY TO THE OUTSIDE OR INTO DUCTING UP TO 4m LONG
Pressure/performance curves
THE SPLASHPROOF VORTICE® PUNTO MODELSARE AVAILABLE IN THE FOLLOWING VERSIONS:
AUTOMATICLONG LIFE 30.000 h
All models are manufactured with long-life ball-bearingmotors which are guaranteed for 30,000 hourscontinuous, trouble-free operation.
The integral shutters positioned behind the front grilleautomatically open and close slowly when the unit isoperated. The shutters are made from shockproof,anti-UV-treated, plastic.
MHC VERSIONThis model has the latest electronicmicro-chip technology which provides
high accuracy and continuous monitoring of both temperature and humidity.Intelligent self-adjusting switch-point which helps eliminate condensation at
source, reduces health hazards and call backs.
PULL CORDThe unit is switched on by pulling theinsulated pull cord.
INTEGRAL “PIR” SENSORThe unit turns on a few seconds afterthe person has entered the room
(sensor is located in an inclined position to increase sensitivity), andcontinues to operate during the person’s presence. When the person leavesthe room, the unit will continue to run from between 3 to 20 minutesdepending on the timer setting.
TIMER The timer comes on when the light isswitched on. When the light is turned
off, the unit continues to operate for 3 to 20 minutes, depending on thetimer setting.
TIMER
PULLCORD
PIR Passive Infrared
T-HCS VERSIONThe unit turns on when relativehumidity exceeds 65% and it turns
back off when the RH drops back to 65%. When the light is switched off,the unit will continue to run from between 3 to 20 minutes depending onthe timer setting.
T-HCS Humidity Control System - Timer
MHC MicroprocessorHumidity Control
THE VORTICE® PUNTO MODELS ARE AVAILABLEIN THE FOLLOWING OPTIONS:
Delivery
RpmProduct Approvals Insulation
Supply and install a Punto domestic axial extract fan (with or without automatic shutters), for installation in wall, window or ceiling as manufacturedexclusively by Vortice only for Vortice. The fan should have a performance in excess of the requirements of the Building Regulations (Document F),even when installed with up to 4 m x (100mm, 120mm and 150mm diameters to suit the three model sizes) of flexible aluminium ducting with 2 number90 degree bends. The requirements are 15l/s for Bathrooms/Toilets – 30 l/s for Utilities and 60 l/s for Kitchens (model with a 15 minute overrun timer forinternal rooms). It should be tested and certified as IPX4 (splashproof) with all performance data third party IMQ (BEAB recognised equivalent) verified. The fan should be made from anti-UV ABS plastic and all components and packaging to be 100% recyclable. The internal cover should be of a snap fixdesign. The motor should be either a bronze bush or a stainless steel ball bearing, shielded pole motor (30,000-hour guarantee), be capable ofoperating at an ambient temperature up to 50°C and include a thermal cut out device. Control options should include: Speed control (using an optionalcontroller), Pull cord, Timer, PIR (passive Infrared), T-HCS (humidity control system-timer) and MHC (microprocessor humidity control).
STANDARD All models are manufactured withshielded poles and have bronze bearingsfor a long life
12 V MODELS A power supply unit is neededwherever the use of low-voltage
equipment is required. The two available low-voltage fans - one with and onewithout automatic shutter - can be used in combination with any of the powersupply units.
12 V Power SupplyUnit
00.PUNTO DEF 30-06-2003 16:20 Pagina 18
2120
BATHROOM, SHOWER,TOILET11203
11201 M 100/4” 11636 M 100/4” A MHC 11232 M 100/4” AT LL + M 100/4” 12 V T HCS22157
1120311641 M 100/4” P 11202 M 100/4” LL 11684 M 100/4” A PIR LL + M 100/4” 12 V MHC
22153
1122311211 M 100/4” T 11642 M 100/4” P LL 11601 M 100/4” T HCS + M 100/4” 12 V A
22150
1122311681 M 100/4” PIR 11212 M 100/4” T LL 11611 M 100/4” AT HCS + M 100/4” 12 V AP
22152
1122311626 M 100/4” MHC 11682 M 100/4” PIR LL 11612 M 100/4” AT HCS LL + M 100/4” 12 V AT
22151
1122311221 M 100/4” A 11602 M 100/4” T HCS LL 11637 M 100/4” A MHC LL + M 100/4” 12 V AT HCS
22157
11203 1122311646 M 100/4” AP 11627 M 100/4” MHC LL + M 100/4” 12 V + M 100/4” 12 V A MHC
22150 22153
1120311231 M 100/4” AT 11222 M 100/4” A LL + M 100/4” 12 V P –
22152
1120311683 M 100/4” A PIR 11647 M 100/4” AP LL + M 100/4” 12 V T –
22151
UTILITY ROOM
11301 M 120/5" 11331 M 120/5” AT 11322 M 120/5” A LL 11737 M 120/5" A MHC LL
11741 M 120/5" P 11783 M 120/5" A PIR 11747 M 120/5" AP LL 11702 M 120/5" T HCS LL
11311 M 120/5" T 11302 M 120/5" LL 11332 M 120/5" AT LL 11722 M 120/5" AT HCS LL
11781 M 120/5" PIR 11742 M 120/5" P LL 11784 M 120/5” A PIR LL 11726 M 120/5" MHC
11321 M 120/5" A 11312 M 120/5” T LL 11701 M 120/5“ T HCS 11736 M 120/5” A MHC
11746 M 120/5” AP 11782 M 120/5” PIR LL 11721 M 120/5” AT HCS 11727 M 120/5” MHC LL
SPLASHPROOF AXIAL EXTRACT FANS USED TO EXTRACT AIR EITHERDIRECTLY TO THE OUTSIDE OR INTO DUCTING UP TO 4m LONG
SPLASHPROOF AXIAL EXTRACT FANS USED TO EXTRACT AIR EITHERDIRECTLY TO THE OUTSIDE OR INTO DUCTING UP TO 4m LONG
Application
AUTOMATIC
TIMER
“NORMALOPERATION”
PULLCORD
PIR Passive Infrared
T-HCS Humidity Control System - Timer
MHC MicroprocessorHumidity Control
LONG LIFE 30.000 h
“Wallinstallation”
“Ceiling installation(with Kit: 22154/22155/22156)”
“Window installation(with Kit: 22131/22132/22133)”
“ROOM WITHOUTWINDOW”
“CONDENSATIONCONTROL”
"AUTOMATICCONDENSATION
CONTROLSYSTEM"
PIRFUNCTIONING
“Wallinstallation”
“Ceiling installation(with Kit: 22154/22155/22156)”
“Wallinstallation”
“Ceiling installation(with Kit: 22154/22155/22156)”
“Window installation(with Kit: 22131/22132/22133)”
“Wallinstallation”
“Ceiling installation(with Kit: 22154/22155/22156)”
“Window installation(with Kit: 22131/22132/22133)”
“Wallinstallation”
“Ceiling installation(with Kit: 22154/22155/22156)”
“Window installation(with Kit: 22131/22132/22133)”
Labels to chooseModel Option
AUTOMATIC
LONG LIFE 30.000 h
AUTOMATIC
LONG LIFE 30.000 h
AUTOMATIC
LONG LIFE 30.000 h
AUTOMATIC
LONG LIFE 30.000 h
Note: The ceiling kit is to preserve IPX4 integrity
Model Code Suitable for use with
Fixed grille 22010 11221 - 11231 - 11611 - 11646 - 11683 - 11222 - 11232 - 11637 - 11684
22020 11321 - 11331 - 11721 - 11746 - 11783 - 11421 - 11431 - 11808 - 11856 - 11883 - 11332 11737 - 11747 - 11784 - 11422 - 11432 - 11837 - 11857 - 11884
Gravity type grille 22300 11201 - 11211 - 11601 - 11641 - 11681 - 11202 - 11212 - 11642 - 1168222330 11301 - 11311 - 11201 - 11741 - 11781 - 11302 - 11312 - 11782 - 11742 - 1140222360 11401 - 11411 - 11801 - 11851 - 11881 - 11412 - 11853 - 11882
Grille kit 22140 11100 - 11101 - 11110 - 1111122141 11102 - 11103 - 1111622142 11104 - 11105 - 1111722143 11110 - 11111
SCNR electronic speed controller 12912 11201 - 11202 - 11301 - 11302 - 11401 - 11402
SCNRB recessed electronic speed controller 12971 11201 - 11202 - 11301 - 11302 - 11401 - 11402
Window kit 22131 11221 - 11231 - 11611 - 11646 - 11683 - 11222 - 11232 - 11637 - 1168422132 11321 - 11331 - 11721 - 11746 - 11783 - 11322 - 11332 - 11737 - 11747 - 1178422133 11421 - 11431 - 11808 - 11856 - 11883 - 11442 - 11432 - 11837 - 11857 - 11884
Ceiling kit 22154 11201 - 11211 - 11601 - 11681 - 11221 - 11231 - 11611 - 11683 - 11202 - 11212 - 11682 - 11222 - 11232 - 11637 - 1168422155 11301 - 11311 - 11701 - 11781 - 11321 - 11331 - 11721 - 11783 - 11302 - 11312 - 11782 - 11322 - 11332 - 11737 - 1178422156 11401 - 11411 - 11801 - 11881 - 11421 - 11431 - 11808 - 11883 - 11402 - 11412 - 11882 - 11422 - 11432 - 11837 - 11884
TYPE OF ROOM
∅ 120: UTILITY ROOM
∅ 100: BATHROOM,SHOWER,TOILET
∅ 150: KITCHEN
VORTICE® PUNTO ACCESSORIES
KITCHEN
11401 M 150/6" 11431 M 150/6" AT 11857 M 150/6" AP LL 11837 M 150/6" A MHC LL
11851 M 150/6" P 11883 M 150/6" A PIR 11432 M 150/6" AT LL 11802 M 150/6" T HCS LL
11411 M 150/6" T 11402 M 150/6" LL 11882 M 150/6" PIR LL 11809 M 150/6" AT HCS LL
11881 M 150/6" PIR 11853 M 150/6" P LL 11884 M 150/6" A PIR LL 11826 M 150/6" MHC
11421 M 150/6" A 11412 M 150/6" T LL 11801 M 150/6" T HCS 11836 M 150/6" A MHC
11856 M 150/6" AP 11422 M 150/6" A LL 11808 M 150/6" AT HCS 11827 M 150/6" MHC LL
00.PUNTO DEF 30-06-2003 16:21 Pagina 20
2322
A B C
F 100/4” 158 69 22 123÷128 20
F 120/5” 179 80 33 143÷148 20
F 150/6” 213 87 40 178÷183 20
A B
C
➀ ➁
F 120/5” 22132 20 0.12 2000 140 38.9 40.5 1.15 cl.II X4 50
F 150/6” 22133 30 0.15 1950 280 77.8 44.5 1.56 cl.II X4 50
F 100/4” 22131 18 0.1 2300 85 23.6 38 0.85 cl.II X4 50
Kit AW Lp dB(A)3 m kg IP °C
max
M 100/4”
M 120/5”
M 150/6”
m3 /
h
l/s
S 100/4” 22154
S 120/5” 22155
S 150/6” 22156
➀ Single-glazed windowinstallation with window kit.
➁ Double-glazed windowinstallation with window kit.
■ Made of soft rubber to preventwater infiltration and to maintain IPX4protection on all surfaces.
■ Will allow any Vortice®
Punto unit to be fitted toany single or double glazedwindow.
■ The data and performances forthe product + kit are IMQ certifiedwith Data Label.
■ The kit consists of closed-cell,expanded-polyethylene gasketand external grille, intermediateflange fitting, spacer, and a anti-UV-threaded ABS ring.
■ Glass thickness: 2/3 mm (min) -17/20 mm (max).
■ Conforms to the followingstandards: EN 60335-2-80 (Part 2:Particular requirements for fans),EN 60529 (Code IP) and CEI 107-53/1986.
Design: F. Trabucco & Associates
KIT TO WINDOW-MOUNT ANYVORTICE® PUNTO MODEL
VORTICE® PUNTO ACCESSOIRES VORTICE® PUNTO ACCESSOIRES
Dimensions (mm)
The following are the performance values for the product + kit
Ceiling Kit
CodeProduct Rpm
Delivery
Approvals Insulation
Code
Accessories on request (description and data on page 54)
Model Code Products
11201 - 11202 - 11203 - 11211 - 11212 - 11221 - 22010 11222 - 11223 - 11231 - 11232 - 11612 - 11637 -
Fixed Grille11682 - 11684
11301 - 11302 - 11311 - 11312 - 11321 - 11322 -
22020 11331 - 11332 - 11401 - 11402 - 11411 - 11412 - 11421 - 11422 - 11431 - 11432 - 11722 - 11737 - 11782 - 11784 - 11809 - 11837 - 11882 - 11884
11201 - 11202 - 11203 - 11211 - 11212 - 11221 -22300 11222 - 11223 - 11231 - 11232 - 11612 - 11637 -
11682 - 11684
11301 - 11302 - 11311 - 11312 - 11321 - 11322 - Gravity type grille 22330
11331 - 11332 - 11722 - 11737 - 11782 - 11784
11401 - 11402 - 11411 - 11412 - 11421 - 11422 - 22360
11431 - 11432 - 11809 - 11837 - 11882 - 11884
22140 11100 - 11101 - 11110 - 11111
Grille kit22141 11102 - 11103 - 1111622142 11104 - 11105 - 1111722143 11110 - 11111
SCNR electronic speed controller 12912 11201 - 11202 - 11301 - 11302 - 11401 - 11402
SCNRB recessed electronic speed controller 12971 11201 - 11202 - 11301 - 11302 - 11401 - 11402
∅ hole glass thickness max
00.PUNTO DEF 30-06-2003 16:21 Pagina 22
➀ ➂➁
m3/h
l /s 0
mmH2OPa
30
20
10
0
p
t
10 20
4
3
2
1
00 5025
qv
75 100
A
B
C
24
A B C
GA 12V 161 117 65
VORTICE® PUNTO RANGE
■ For intermittent orcontinuous ventilation ofbathrooms, toilets, kitchensor utility rooms in domesticor commercial business.
■ 2 models available with or withoutautomatic shutters.
■ In the automatic version theshutters positioned behind thefront grille automatically open andclose slowly when the unit isoperated. The shutters are madefrom shockproof, anti-UV-treatedplastic.
■ 12V motor with shielded poles,bronze bearings and thermalcut-out.
■ IMQ data label ensures data andperformance is certified.
■ High airflow rate, low operatingnoise level and low powerconsumption due to the wing-
Dimensions (mm)
profile blades and motor support.■ IPX4 splashproof protection.■ Motor support and grille made of
anti-UV ABS.■ Conforms to the following
standards: EN 60335-2-80 (Part 2:Special standards for ventilators),EN 60529 (Code IP) and CEI107-53/1986.
Design: F. Trabucco & Associates
Accessories(description and data on page23 and 54)
■ Window kit.■ Ceiling kit.■ Fixed grille.■ Gravity grille.
Wiring diagrams shown on page XXVII.
➀ Installation showing extract directly to the outside.➁ Ceiling installation on up to 4m duct.➂ Through the wall insulation with wall sleeve and grille.
SPLASHPROOF AXIAL FANS USED TO EXTRACT AIR EITHERDIRECTLY TO THE OUTSIDE OR INTO DUCTING UP TO 4m LONG.
Pressure/performance curve
11223 12 18 0.1 2300 90 25 3 29 38 0.6 Selv cl.III X4 50
AV ~ 50Hz W Lp dB(A)
3 m kg IP °Cmax
M 100/4” 12 V
11203 12 18 0.1 2300 90 25 3 29 38 0.6 Selv cl.III X4 50
m3 /
h
mm
H2O
Pa
l/s
P max
Product T/mn
Delivery
Approvals Insulation
M 100/4” A12 V
Code
Product Standard Pull Cord Timer T HCS MHC
M 100/4” 12 V22150 22152 22151 22157 22153
M 100/4” A 12 V
With 12 V Power Supply - Transformer
12 V
00.PUNTO DEF 30-06-2003 16:21 Pagina 24
25
■ For intermittent orcontinuous ventilation ofkitchens, and small/mediumrooms in domestic orcommercial properties.
■ Motor support and grille made ofanti-UV ABS.
■ Two speed shielded pole motorwith ball bearings and thermalcut-out.
■ Shutters which slowly open andclose when the unit is turned onand off.
■ The unit can be window mountedusing a Vortice window kit(F150/6” - code 22133).
■ The pullcord should be removed,and a remote over ride switch (notsupplied) fitted.
■ A ceiling kit (S150/6” - code22156) is required to maintainIPX4 intergrity.
■ Can be used on up to 4 metres ofcircular ducting with 2 x 90degree bends.
Design: F. Trabucco & Ass.
Accessories(description and data on page23 and 54)
■ Window kit.■ Ceiling kit.■ Fixed grille.■ Gravity grille.
Wiring diagrams shown on page XXVII. ➀ Installation showing extract directly to the outside.➁ Ceiling installation on up to 4m duct.➂ Through the wall insulation with wall sleeve and grille.
WALL,WINDOW AND CEILING MOUNTED AXIAL FAN WITH PULLCORD AND HUMIDISTAT,TWO SPEEDS AND AUTOMATIC SHUTTERS
A
V ~
50
Hz W
Lp dB(A)3 m kg IP °C
max
M 150/6”
230-11854 240 6 30 0.07 0.15 760 2100 110 335 30.5 93.5 0.7 6 6.8 59 24 46 1.1 cl.II X4 50
m3/h l/sProduct
Rpm Delivery
Approvals InsulationCode
➀ ➂➁
qv
l/s 0
mmH2OPa
60
40
20
0
p t
8
6
4
2
00 200100 300 400
30 60 90
m3/h
Pressure/performance curve
A B C D ∅ E
M 150/6” 214 215 117 47 156
B ∅ E
A
D
CDimensions (mm)
min
max
min
max
min
max
min
max
min
max
mmH2O Pa
P max
min
max
min
max
min
max
VORTICEPUNTO M150/6”APHCSDLL LONG LIFE 30.000 h
Pull cord feature. An integral pull cord allowing the user to manuallyswitch the unit on at maximum speed. An indicator light is illuminatedwhen in manual over-ride. The over-ride facility can also be connected toa remote switch not supplied).
HCS Feature. Complete with an HCS (Humidity Control System) humiditysensor, the unit switches on at low speed when humidity exceeds the setpoint, and off again once humidty drops below the set point. The RelativeHumidity (R.H.) set point is adjustable between 60% and 80% (±3%). It isalso possible to over ride the HCS facility by using the pull cord whichswitches the fan on at full speed.
01.DOMESTICO DEF1 30-06-2003 16:40 Pagina 25
26 27
8 mm
VORTICE PUNTO SLIM RANGE
■ Due to their ultra slim grilleprofile, slim in-line fans canblend unobtrusively intoevery kind of environment.Suitable for installation inwalls, ceilings/falseceilings. Complies with therequirements of Part F1 ofthe Building Regulationseven when connected on3m flexible aluminium duct(with 2 x 90° bends)
■ 4 models available with or withouttimer ∅ 90 and 100 mm
■ The timer is adjustable for 3 to 20minutes.
■ IMQ data label ensures data
IN-LINE AXIAL FANS SUITABLE FOR UNOBTRUSIVE WALL OR DUCTED INSTALLATION
and performance is third partycertified.
■ Motor with shielded poles and ballbearings (30.000 h guaranteedcontinuous operation) with thermalcut-out. Except codes (11112-11113).
■ High airflow rate and lowoperating noise level due to wing-profile blades.
■ Ultra slim grille and grille holdermade of anti-uv absthermoplastics.
■ IPX4 splashproof protection on allmodels.
■ Conforms to the followingstandards: EN 60335-2-80 (part 2:Particular requirements for fan),EN 60529 (code IP) and CEI 107-53/1986.
Design: F. Trabucco & Associates
Accessories(description and data on page 54)■ SCNR electronic speed controller
for standard models (code 12912)■ SCNRB built-in electronic speed
controller for standard models(code 12971)
■ Grille kit (code 22140-22143)■ 3m ∅ 100mm flexible aluminium
duct (code 22050)■ Surface wiring kit (code 22253)
Wiring diagrams shown on page XXVII.
➀ Unique and stylish ultra slim grille (just 10,5 mm max)
LONG LIFE 30.000 h PUNTO GHOST KIT RANGE
■ For continuous ventilation oftoilet, bathroom, kitchen andutility room in domesticproperties. Complies withthe requiremens of Part F1 ofthe Building Regulationseven when connected on 3mflexible aluminium duct(with 2 x 90° bends).
■ 2 models available with or withouttimer ∅ 100 mm.
■ The timer is adjustable from 3 to20 minutes.
■ IMQ data label ensures data andperformance is third party certified
■ Motor with shielded poles and ballbearings (30.000 h guaranteedcontinuous operation) with thermalcut-out
■ High airflow rate and lowoperating noise level due
IN-LINE AXIAL FANS ∅ 100 MM WITH OR WITHOUT TIMER, COMPLETE WITH FLEXIBLEDUCT, GRILLES, MOUNTING BRACKET AND PIPE CLAMPS
to wing-profile blades. ■ IPX4 splashproof protection on all
models■ Conforms to the following
standards: EN 60335-2-80 (Part 2:Particular requirements for fan)EN 60529 (Code IP) and CEI 107-53/1986.53/1986.
Design: Trabucco & Associates
Accessories(description and data on page 54)■ SCNR electronic speed controller
(code 12912) not for timerversion.
■ SCNRB recessed electronicspeed controller (code 12971)not for timer version.
Wiring diagrams shown on page XXVII.
Dimensions (mm)
COMPOSITION OF PUNTO GHOST KIT■ MG 100/4”: in-line axial fan ∅ 100 mm■ Mounting brackets: made of PS shock-resistant resin for ceiling / loft
mounting. ■ Flexible aluminium duct extendible up to 3m■ Pipe clamps■ Gravity grille (suitable for external protection) and fixed grille (internal and
external protection) made of ABS thermoplastic.
m3 /
h
mm
H2O
Pa
l/s
AV ~ 50 Hz WLp dB(A)
3 m kg IP °Cmax
MGK 100/4”
11106 230-240 18 0.1 2415 80 22 2.6 25 39 0.9 cl.II X4 40
P max
MGK 100/4”T
11107 230-240 18 0.1 2415 80 22 2.6 25 39 0.9 cl.II X4 40
Delivery
RpmProduct Approvals InsulationCode
LONG LIFE 30.000 h
D
A
B
BA C D
C
D
D
∅C
B
Dimensions (mm)Pressure/performance curve
A B ∅ C D
MS 90/3.5” 140 119.5 92.5 109
MS 90/3.5” T 140 119.5 92.5 109
MS 100/4” 140 119.5 99 109
MS 100/4” T 140 119.5 99 109
90 100
MS 100/4” LL
P maxLp dB(A)
3 m
TIM
ER kg IP °CmaxV ~ 50 Hz W A
m3 /
h
mm
H2O
Pa
l/s
11114 11115 230-240 18 0.10 2415 80 22 2.6 25 40 0.48 cl.II X4 40
Product
Code
Rpm
Delivery
Approvals Insulation
MS 90/3.5”
11112 11113 230-240 18 0.10 2450 65 18 2.1 21 38 0.45 cl.II X4 40
A
01.DOMESTICO DEF1 30-06-2003 16:40 Pagina 26
28 29
VORTICE PUNTO GHOST RANGE■ Complies with the
requirements of Part F1 ofthe Building Regulationseven when connected on3m flexible aluminium duct(with 2 x 90° bends).Suitable for installation inwalls, ceilings/falseceilings, lofts, internalwalls. These fans can beused as temperatureblenders in adjacent rooms.
■ 10 models available with andwithout timer ∅ 100-120-150 mm.
■ The timer is adjustable from 3 to20 minutes.
■ IMQ data label ensures data and
performance is third party certified■ Motor with shielded poles and ball
bearings (30.000 h guaranteedcontinuous operation) with thermalcut-out. Except codes (11110-11111-11116-11117).
■ High airflow rate and lowoperating noise level due to wing-profile blades.
■ IPX4 splashproof protection on allmodels.
■ Conforms to the following standards:EN 60335-2-80 (Part 2: Particularrequirements for fans) EN 60529(Code IP) and CEI 107-53/1986.
Design: F. Trabucco & Associates
LONG LIFE 30.000 h
False-ceiling installation(with optional kit).
Installation showingextract directly to theoutside (with optionalkit).
Installation astemperature blenders inadjacent rooms.
Wall installation.
*Available only in UK
Wiring diagrams shown on page XXVII.
IN-LINE AXIAL FANS SUITABLE FOR UNOBTRUSIVE WALL OR DUCTED INSTALLATION NEW
MG ∅ A B C
MG 90/3.5” 92.5 92 89
MG 90/3.5” T 92.5 96.5 89
MG 100/4” LL 99 92 92
MG 100/4” T LL 99 96.5 92
MG 120/5” / LL 119 103 100
MG 120/5” T LL 119 107.5 100
MG 150/6” / LL 155 110 107
MG 150/6” T LL 155 114.5 107
TIM
ER V ~ 50 Hz W A
m3 /
h
mm
H2O
l/s Pa
Lp dB(A)3 m
°CmaxIPkg
P max
11100 11101 230-240 18 0.10 2415 80 22.2 2.6 25 39 0.43 cl.II X4 40
Approvals Insulation
Delivery
Rpm
Code
Product
MG 100/4” LL
11110 11111 230-240 18 0.10 2450 65 18 2.1 21 38 0.45 cl.II X4 40
MG 90/3.5”
∅ A
B
C
Dimensions (mm)
MG 120/5”
MG 120/5” LL
11116 – 230-240 20 0.12 2250 160 44 4.5 44 43 0.56 cl.II X4 50
11102 11103 230-240 20 0.12 2250 160 44.4 4.5 44 43 0.56 cl.II X4 50
MG 150/6”
MG 150/6” LL
11117 – 230-240 30 0.18 2200 320 89 7.0 69 48 0.80 cl.II X4 50
11104 11105 230-240 30 0.18 2200 320 88.9 7.0 69 48 0.80 cl.II X4 50
m3/h
m3/s 0
mmH2OPa
40
30
20
10
0
pt
0,010 0,020
5
4
3
2
1
00 453015 60
qv
75
40
30
20
10
0m3/h
0
mmH2OPa
pt
10 20
5
4
3
2
1
00 4020
qv
80 100
l/s
60
MG 100/4”
m3/h
m3/s 0
mmH2OPa
40
30
20
10
0
pt
0,010 0,020
5
4
3
2
1
00 453015 60
qv
75m3/h
mmH2OPa
pt
10
8
6
4
2
00 16080
qv
320 400
l/s
240
0 30 60 90
50
0m3/h
m3/s 0
mmH2OPa
40
30
20
10
0
pt
0,010 0,020
5
4
3
2
1
00 453015 60
qv
75
40
30
20
10
0m3/h
mmH2OPa
pt
5
4
3
2
1
00 8040
qv
160 200
l/s
120
0 10 20 30 40 50
MG 120/5” MG 150/6”
m3/h
m3/s 0
mmH2OPa
40
30
20
10
0
pt
0,010 0,020
5
4
3
2
1
00 453015 60
qv
75m3/h
0
mmH2OPa
pt
10 20
2,5
2
1,5
1
0,5
00 4020
qv
80 100
l/s
20
10
060
MG 90/3,5”
Pressure/performance curves
Model Code Product
SCNR electronic speed controller 12912 11100 - 11102 - 11104 11110 - 11116 - 11117
SCNRB built-in 12971 11100 - 11102 - 11104electronic speed controller 11110 - 11116 - 11117
22262 11100 - 11101
Complete installation kit 22263 11102 - 11103 - 1111622264 11104 - 11105 - 1111722265 11100 - 11101
22140 11100 - 11101 - 11110 - 11111
Grille kit22141 11102 - 11103 - 1111622142 11104 - 11105 - 1111722143 11110 - 11111
22250 11100 - 11101 - 11110 - 111113 mtrs flexible aluminium duct 22251 11102 - 11103 - 11116
22252 11104 - 11105 - 11117
22253 11100 - 11101 - 11110 - 11111Surface wiring kit 22254 11102 - 11103 - 11116
22255 11104 - 11105 - 11117
22256 - 8021* 11100 - 11101 - 11110 - 11111Telescopic wall liner 22257 - 8035* 11102 - 11103 - 11116
22258 - 8321* 11104 - 11105 - 11117
22259 11100 - 11101 - 11110 - 11111Loft mounting brackets 22260 11102 - 11103 - 11116
22261 11104 - 11105 - 11117
Accessories on request (description and data on page 54)
01.DOMESTICO DEF1 30-06-2003 16:41 Pagina 28
30 31
➋
➌➍
➎
➏
➊
A B C D E F G ∅ H I L M
252 23 65 214.5 228 135.3 31.5/76.7 96.5 180 92 76
LONG LIFE 30.000 h
BF
∅ H
G
E
C
D
L
A
M
I
BF
C
G
E D
I
H
A
ARIETT RECESSED RANGE
■ Suitable for use inbathrooms, shower roomsand toilets. Complete withbrackets and template, theyare designed to be quicklyand easily installed by oneperson. They also have theoption of vertical orhorizontal extract points.
■ Powerful yet very quiet inoperation, the unobtrusive stylingprovides all necessary extractrequirements, while complimentingthe décor of the room. The fansmeet all necessary requirement ofF1 building regulations.
■ The five Ariett models offer thechoice of basic model, a timerversion or built-in microprocessorfor intelligent condensationcontrol.
Wall-mounted with sideextract.
Wall-mounted withperpendicular extract.
Ceiling-mounted. False-ceiling-mountedwith perpendicularextract.
Motor with ballbearings: 30,000 hoursguaranteed continuedoperation.
➊ Unobtrusive front grille.➋ Support springs for the front grille, suitable for 65mm max false ceilings.➌ Metallic filter which can be removed and washed (dishwasher safe).➍ Made of rigid synthetic resin to guarantee high durability.➎ 100 mm dia. Outlet spigot which can be positioned to the rear or side
(using optional accessories).➏ Backdraught-shutter to avoid back-flow when unit is turned off.
CENTRIFUGAL EXTRACTOR FANS, FOR FLUSH MOUNTING IN WALLS OR CEILINGS, PROVIDED WITH IPX4 SPLASHPROOF PROTECTION,THESE FANS ARESUITABLE FOR LONG DUCT RUNS.
False-ceiling-mountedwith low-profile spigot.
Accessories/Ancillaries (see also on page 54)
Wiring diagrams shown on page XXVII.
*Available only in UK
Spare Parts■ Metallic anti-dust filter.
(cod. 1193006023).
Supply and install an Ariett centrifugal extract fan with a removable, integral back draught shutter for flush mounting installation in wall or ceiling andducted applications as manufactured exclusively by Vortice only for Vortice. The fan should have a performance in excess of the requirements of theBuilding Regulations (Document F). The requirements are 15 l/s for bathrooms/toilets/shower rooms and 6 l/s for toilets (model with a 15 minute overruntimer for internal rooms). It should be tested and certified as IPX4 (splashproof) with all performance data third party IMQ (BEAB recognised equivalent)verified. The fan should have an unobtrusive, spring clip-fix front grille complete with washable metallic filter. The rear spigot should provide a choice ofeither vertical or horizontal entry and be able to accept both the optional high and low profile connectors. The motor should include a thermal cut outdevice. Fixing brackets and template should be provided with the fan. Control options should include: Speed control (using an optional controller),Timer and MHC (microprocessor humidity control).
■ All fans have the optional side orrear exit low profile connector, orhigh profile connector.
■ These have been specificallydesigned for ceilings where thevoid area is restricted, forexample, downstairs or betweenfloors. In addition, there isa choice of fixing kits available.A template is supplied to alloweasy cutting of the access hole.
■ Developed with UK house buildersand contractors.
Design: F. Trabucco & Associates
Dimensions (mm)
side outletwith high profile
rear outlet
With high horizontal outlet spigot
Ariett LL I
Product
2450(1) 80(1) 22.2(1)
12012 12013 12014 220-240 19 0.13 2490(2) 70(2) 19.4(2) 11 108 1.9 cl.II X42580(3) 55(3) 15.3(3)
(1)Rear air outlet. (2)Side air outlet with high profile. (3)Side air outlet with low profile.
TIM
ER
MH
C RpmAV ~ 50 Hz W Approvals kg Insulation IP
Ariett I
Code
With low spigot
BF
C
G
E D
m3 /
h
mm
H2O
Pa
l/s
Delivery P max
12010 12011 – 220-240 19 0.132450(1) 80(1) 22.2(1)
11 108 1.9 cl.II X42490(2) 70(2) 19.4(2)
Ariett LL I
Model Code Products
SCNR electronic speed controller 12912 12010 - 12012*
SCNRB electronic speed controller 12971 12010 - 12012*
False-ceiling/wall installation kit 22823 for all products
Wall/ceiling installation kit 22824 for all products
High profile connector 22841 for all products
Low profile connector 22842 for all products
Fixed grille 22010 for all products
Pressure/performance curve
01.DOMESTICO DEF1 30-06-2003 16:41 Pagina 30
32 33
➀ ➁
LONG LIFE 30.000 h LONG LIFE 30.000 h
➀ ➁ ➂
∅ D
BA
F
C
E
m3/h
p t
120
80
40
0
mmH2OPa
qv
l/s 0 10 20
15
10
5
0250 50 75
12015 220-240 18 0.14 2450 70 19.4 12 118 40 1.45 cl.II X4
AV ~ 50 Hz W
Lp d
B(A
)3
m
kg IP
Ariett LL PIR
m3 /
h
mm
H2O
Pa
l/s
P max
A B C ∅ D E F
Ariett LL PIR 156 123 25 97 60 60IP
■ For bathrooms, showers andtoilets.
■ Available with or without timer.■ The timer is adjustable for 3 to 20 min.■ Basic model has bronze bearing
motor. Motor with shielded polesand ball bearings (30,000 hoursguaranteed continuousoperation) with thermal cut-out.
WALL OR CEILING-MOUNTED CENTRIFUGAL EXTRACTOR FANS, WITH IPX4PROTECTION SUITABLE FOR DUCTED INSTALLATION.
ARIETT MODELS
TIM
ERProduct
Code
RpmAV ~ 50 Hz W
Lp d
B(A
)3
m
Approvals kg Insulation
■ IMQ information label certifies thirdparty product data and performance.
■ Complies with the CEI EN 60335-2-80 standards and IPX4splashproof protection.
Design: F. Trabucco and M. Vecchi
Wiring diagrams shown on page XXVII.
Conforms with ISO 3744 for noise and pressure levels
11965 11966 220-240 18 0.14 2450 70 19.4 12 118 40 1.47 cl.II X4
Ariett LL
Dimensions (mm)
Supply and install an Ariett centrifugal extract fan with integral backdraught shutter for installation in wall or ceiling and ducted applications asmanufactured exclusively by Vortice only for Vortice. The fan should have a performance in excess of the requirements of the Building Regulations
(Document F). The requirements are 15l/s for bathrooms/toilets/shower rooms and 6 l/s for toilets (model with a 15 minute overrun timer for internalrooms). It should be tested and certified as IPX4 (splashproof) with all performance data third party IMQ (BEAB recognised equivalent) verified. The fan should have a high impact ABS thermoplastic resin cover and be supplied with an anti vibration support gasket for tiled or uneven walls.The motor should be either a bronze bush or a stainless steel ball bearing, shielded pole motor (30,000-hour guarantee), and include a thermal cut outdevice. Control options should include: Speed control (using an optional controller), Timer and MHC (microprocessor humidity control).
➀ Ducted installation.➁ Wall or ceiling-mounted installation. ➂ Model LL with motor with ball
bearings: 30,000 h of guaranteed continuous operation.
m3 /
h
mm
H2O
Pa
l/s
Delivery P max
A B C ∅ D E F
Ariett 156 123 25 97 60 60
E
F
C B
∅ D
A
Accessories on request (description and data on page 54)
m3/h
p t
120
80
40
0
mmH2OPa
qv
l/s 0 10 20
15
10
5
0250 50 75
11961* 11976* 220-240 18 0.14 2450 70 19.4 12 118 40 1.47 cl.II X4
Ariett
Pressure/performance curve
➂
LONG LIFE 30.000 h
m3/h
p t
120
80
40
0
mmH2OPa
qv
l/s 0 10 20
15
10
5
0250 50 75
Product Code Rpm
Delivery
Approvals Insulation
NEW
ARIETT LL PIR
■ For the ventilation of areaswith intermittent use (smallbathrooms, private or publictoilets).
■ Motor with shielded poles and ballbearings (guaranteed for 30,000fault-free hours of operation) andthermal overload protection.
■ Certified data and performancescompliant with IMQ requirements.
■ Manufactured in compliance withCEI 60335-2-80 standards, IPX4splashproof protection.
Design: F. Trabucco and M. Vecchi
Accessories(description and data on page 54)■ Air flow deflector (code 22310)
not available in UK.■ Fixed grille (code 22010).
Wiring diagrams shown on page XXVII.
➀ Wall or ceiling mounted.➁ Ducted installation.➂ PIR Sensor: turns on automatically after person enters the room.
Activation range of PIR detector.Pressure/performance curve
Dimensions (mm)
WALL OR CEILING MOUNTED CENTRIFUGAL EXTRACTOR FAN WITH LONG LIFEMOTOR AND IPX4 PROTECTION.AUTOMATICALLY OPERATED BY A PIR DETECTOR
Conforms to ISO 3744 for noise and pressure levels.
h = 225 cmH1 = 170 cm
L1 = 70 cmH2 = 150 cm
L2 = 100 cm� = 52°
*Available only in UK
Model Code Products
Electronic thermo-humidistat Humidity Control 12908 11965 - 11961
SCNR electronic speed controller 12912 11965 - 11961
SCNRB electronic speed controller 12971 11965 - 11961
Fixed grille 22010 for all products
01.DOMESTICO DEF1 30-06-2003 16:42 Pagina 32
34
➊
➌
➍
➎
➋➏
m3/h
p t
120
80
40
0
mmH2OPa
qv
l/s 0 10 20
15
10
5
0250 50 75
11962 220-240 18 0.14 2450 70 19.4 12 118 40 1.45 cl.II X4
AV ~ 50 Hz W
Lp d
B(A
)3
m
kg IP
Ariett LL MHC
m3 /
h
mm
H2O
Pa
l/s
P max
LONG LIFE 30.000 h
➀ ➂➁
E
F
C B
∅ D
A
A B C ∅ D E F
Ariett LL MHC 156 123 25 97 60 60
35
Pressure/performance curve
Product Code Rpm
Delivery
Approvals Insulation
WALL AND CEILING-MOUNTED CENTRIFUGAL EXTRACTOR FANS WITH ELECTRONICMICROPROCESSOR FOR AUTOMATIC RELATIVE HUMIDITY AND TEMPERATURE CONTROL.
ARIETT LL MHC
■ Includes samecharacteristics as the LLmodels described on theprevious page.
■ Latest electronic micro-chiptechnology provides highaccuracy in continuous monitoringof both temperature and humidity.
■ Intelligent self-adjusting switch-point which helps eliminate
Dimensions (mm)
condensation at source and reducehealth hazards and call backs.
■ Low temperature (night time)set-back facility.
■ Every model can be optionallywired to operate an over-run timer.
Design: F. Trabucco and M. Vecchi
Wiring diagrams shown on page XXVII.
➀ Ducted installations.➁ Wall or ceiling-mounted.➂ The microprocessor continually monitors the ambient conditions to
maintain the ideal room conditions.
➊ High impact ABS thermoplastic resin cover. ➋ Nylon-fibreglass fan blades.➌ Antivibration support gasket, used for mounting on tiled or uneven walls.➍ Backdraught shutter to avoid back flow when unit is turned off.➎ 100 mm dia. outlet spigot.➏ Complete with fixings.
Conforms with ISO 3744 for noise and pressure levels
LONG LIFE 30.000 h
➀ ➁ ➂
VORT PRESS 220 RANGE P HCS D LL
■ For intermittent orcontiounous ventilation ofkitchens, and small/mediumrooms in domestic orcommercial properties.
■ Housing, motor support andgrille made of high-impact ABSthermoplastic resin.
■ Motor and fan mounted on anti-vibration supports.
■ Removable washable metalic filter.
■ Silent silicon back draughtshutter.
■ The unit can be rotated by 90degrees to allow the optimumsiting of the unit duringinstallation.
■ The pullcord should be removed,and a remote over ride switch(not supplied) fitted.
Design: F. Trabucco - M. Vecchi
Pressure/performance curve
WALL OR CEILING MOUNTED CENTRIFUGAL FAN WITH PULL CORDAND HUMIDISTAT
NEW
40
32
24
16
8
0
mmH2OPa
p t
300
200
100
0m3/h
l/sqv
0 20 40
0 50 150100 200 250
60 max
min
11926 220-240 68 35 0.3 0.24 2060 1200 220(1) 120(1) 33(3) 32(3)
55 43 2.3
cl.II
X461.1(2) 33.3(2) 324(4) 314(4)
P maxAV ~ 50 Hz WLp dB(A)
3 m kg IP
Vort Press 220P HCS D LL
max
min
max
min
max
min
max
min
max
min
max
min
(1)m3/h - (2)l/s - (3)mm H2O - (4)Pa Conforms with ISO 3744 for noise and pressure levels
Product Code Rpm Delivery Approvals
Insu
latio
n
Vort Press A B C ∅ D E
220 P HCS D LL 275 140 28 97 73
Dimensions (mm)
Pull cord feature. An integral pull cord allowing the user to manuallyswitch the unit on at maximum speed. An indicator light is illuminatedwhen in manual over-ride.The over-ride facility can also be connected toa remote switch (not supplied).
HCS Feature. Complete with a HCS (Humidity Control System) humiditysensor, the unit switches on at low speed when humidity exceeds the setpoint, and off again once humidty drops below the set point.The Relative Humidity (R.H.) set point is adjustable between 60% and80% (±3%). It is also possible to over ride the HCS facility by using thepull cord which switches the fan on at full speed.
➀ Ducted installation.➁ Wall or ceiling installation.➂ Kitchen installation.
D
C
A
B
B E
A
E
∅
01.DOMESTICO DEF1 30-06-2003 16:43 Pagina 34
W Lp 1mdB(A) KgP max
V ~
50
Hz
min
max
A
min
max
min
max
min
max
min
max
min
max
36 37
➀ ➁ ➂
A
E
E
B
∅ D
C
E
F
C B
∅ D
A
➀ ➂➁
LONG LIFE 30.000 h LONG LIFE 30.000 h
m3/h
p t
80
40
0
mmH2OPa
qv
l/s 0 5 10
12
8
4
00 15 4530 m3/h
p t
120
80
40
0
mmH2OPa
qv
l/s 0 10 20
15
12
9
6
3
00 20 6040 80 100
max
min
25
20
15
10
5
0
mmH2OPa
p t
200
150
100
50
0m3/h
qv
l/s 0 10 20 30
0 30 60 90 120 150
40
m3/h
p t
120
80
40
0
mmH2OPa
qv
l/s 0 10 20
15
12
9
6
3
00 25 7550 100 125
30
max
min
30/90 45/135
A B C ∅ D E F
Ariett Habitat 156 123 25 97 60 60
WLp 1mdB(A)
12000 230 5 8 0.02 0.04 1260 187020
(1)
43(1)
8(1)
10(1)
30 41.5 1.2cl.II
X45.6(2) 11.9(2) 78(2) 98(2)
12001 230 6 25 0.03 0.17 890 2470 27(1) 85(1)
8(1)
12(1)
30.5 51 1.4cl.II
X47.5(2) 23.6(2) 78(2) 118(2)
Kg
LL 15/30
LL 20/75
P max
Ariett Habitat
Ariett Habitat
VP Habitat A B C ∅ D E
30/90 202 147 30 97 73
45/135 275 140 28 97 73
LL 30/90
LL 45/135
12002 230 8 22 0.06 0.18 820 145051(1) 101(1) 4(1) 14(1)
28.5 44.5 2.1cl.II14.2(2) 28.1(2) 39(2) 137(2)
X4
12004 230 4 29 0.04 0.12 430 1170 52(1) 149(1) 5(1) 23(1)
26.5 48 2.7cl.II
X414.4(2) 41.4(2) 49(2) 225(2)
Vort Press Habitat
Vort Press Habitat
V ~
50
Hz
min
max
A
min
max
min
max
min
max
min
max
min
max
IP
(1) m3/h - (2) l/s - (3) mm H2O - (4) Pa
IP
(1) m3/h - (2) l/s - (3) mm H2O - (4) Pa
15/30 20/75
ARIETT® LL HABITAT RANGE
WALL OR CEILING-MOUNTED TWO-SPEED, CENTRIFUGAL EXTRACTOR FANS,WITH IPX4PROTECTION, FOR EXTRACTION EITHER DIRECTLY TO THE OUTSIDE OR INTO DUCTING.
Dimensions (mm)
■ For continuous ventilation,with boost facility. Ideal foruse in public sector housingin bathrooms, showers,utilities and toilets.
■ Two models. Habitat 15/30 can beused to provide trickle ventilationfor rooms housing open-fluedcombustion appliances.
■ Motor with shielded poles and ballbearings (30,000 h guaranteedcontinuous operation) with thermalprotection.
■ Two speed motor.■ IMQ information label certifies third
party product data and performance.■ Complies with the CEI EN 60335-2-80
standards and IPX4 protection.■ Low power consumption.■ Fully comply with F1 Building
Regulations, plus 1.9D alternativeapproaches.
■ Antivibration support gasket, usedfor mounting on tiled or uneven walls.
■ Backdraught shutter to avoid backflow when unit is turned off.
■ 100 mm dia. outlet spigot.■ Complete with fixings.
Design: F. Trabucco - M. Vecchi
Accessories(description and data on page 54)
Wiring diagrams shown on page XXVII.
➀ Ducted installation. ➁ Wall or ceiling-mounted installation.➂ Motor with ball bearings: 30,000 h of guaranteed continuous operation.
Pressure/performance curves
WALL OR CEILING-MOUNTED CENTRIFUGAL EXTRACTOR FANS, WITH IPX4PROTECTION SUITABLE FOR DUCTED INSTALLATION.
VORT PRESS® LL HABITAT RANGE
■ For continuous ventilationwith boost facility. Ideal foruse in public sector housesin bathrooms, showers,toilets, utility rooms andkitchens.
■ Two models.■ Motor with ball bearings
(guaranteed 30,000 hours ofcontinuous operation) with thermalcut-out.
■ Two speed motor.■ Double motor-fan housing, anti-
vibration supports andbackdraught shutter for silentoperation.
■ Complies with the CEI EN 60335-2-80 standards and IPX4protection.
■ Low power consumption.■ Metallic filter which can be
removed and washed (dishwashersafe)
■ Fully comply with F1 BuildingRegulations, plus 1.9D alternativeapproaches.
Design: F. Trabucco - M. Vecchi
Accessories(description and data on page 54)
Spare Parts■ Metallic anti-dust filter
(30/90: code 1193006019 -45/135: code 1193006021).
Wiring diagrams shown on page XXVII. ➀ Ducted installation. ➁ Wall or ceiling installation.➂ Motor with ball bearings: 30,000 hours guaranteed continuous operation.
Dimensions (mm)Pressure/performance curves Pressure/performance curves
Product Code Rpm Delivery
App
rova
ls
Insu
latio
n
Product Code Rpm Delivery
App
rova
ls
Insu
latio
n
Supply and install a Vort Press Habitat centrifugal extract fan with removable, integral backdraught shutter for installation in wall or ceiling and ductedapplications as manufactured exclusively by Vortice only for Vortice. The fan should provide continuous trickle ventilation at low speed and have a secondboost speed option and comply with the requirements of the Building Regulations (Document F) and the alternative approach 1.9D. The requirements are15 l/s for bathrooms/toilets/shower rooms and 6 l/s for toilets – alternative approach 1.9D requires 0.5 ACH throughout the dwelling. It should be testedand certified as IPX4 (splashproof) with all performance data third party IMQ (BEAB recognised equivalent) verified. The fan should be manufactured from durable, rigid synthetic resin and have a clip-fix front grille complete with washable metallic filter. The motor shouldbe a stainless steel ball bearing, shielded pole motor (30,000-hour guarantee), and include a thermal cut out device. It should consume 8 Watts per hour,or less, on trickle speed.
Supply and install an Ariett Habitat centrifugal extract fan with integral backdraught shutter for installation in wall or ceiling and ducted applications asmanufactured exclusively by Vortice only for Vortice. The fan should provide continuous trickle ventilation at low speed and have a second boost speedoption and comply with the requirements of the Building Regulations (Document F) and the alternative approach 1.9D. The requirements are 15 l/s forbathrooms/toilets/shower rooms and 6 l/s for toilets – alternative approach 1.9D requires 0.5 ACH throughout the dwelling. The 15/30 version should becapable of providing trickle ventilation in rooms where open flued combustion appliances are used. It should be tested and certified as IPX4 (splashproof)with all performance data third party IMQ (BEAB recognised equivalent) verified. The fan should have a high impact ABS thermoplastic resin cover andbe supplied with an anti vibration support gasket for tiled or uneven walls. The motor should be a stainless steel ball bearing, shielded pole motor(30,000-hour guarantee), and include a thermal cut out device. It should consume 6 Watts per hour, or less, on trickle speed.
■ Low power consumption.■ Metallic filter which can be
removed and washed (dishwashersafe)
■ Fully comply with F1 BuildingRegulations, plus 1.9D alternativeapproaches.
Design: F. Trabucco - M. Vecchi
Accessories(description and data on page 54)
Spare Parts■ Metallic anti-dust filter
(30/90: code 1193006019 -45/135: code 1193006021).
Wiring diagrams shown on page XXVII.
01.DOMESTICO DEF1 30-06-2003 16:43 Pagina 36
mmH2OPa
p t
0 5025 75m3/h
qv
l/s 0
50
0
10
9
6
3
0
20
mmH2OPa
p t
0m3/h
qv
l/s 0
150
100
50
0
10 20 30
18
12
6
0150
40
10050
I
H
A
m3/h
l/s
mmH2OPa
p t
50
00 20 40 60
qv
0 10 20
80
8
6
4
2
0
38 39
LONG LIFE 30.000 h
m3/h
l/s
mmH2OPa
p t
200
150
100
50
00 25 7550 100
qv
0 10 20
125
30
24
20
16
12
8
4
0150
40
p t
qv
50
40
30
20
10
0
mmH2OPa
400
300
200
100
0m3/h
l/s 0 20 40
0 50 150100 200 250
60
➊
➋
➌➍
➎
➏
35
28
21
14
7
0
mmH2OPa
p t
300
200
100
0m3/h
l/sqv
0 20 40
0 30 15060 90 120
110 - Max 110 - Min
140 - Max 140 - Min
240 - Max 240 - Min
BE
F
D
C
H
I
A
∅ G
BF
∅ H
G
E
C
D
L
A
M
I
BF
C
G
E D
Vort Press LL I A B C D E F G ∅ H I L M
110 252 23 65 214.5 228 135.3 31.5/76.7 96.5 180 92 76
Vort Press LL I A B C D E F ∅ G H I
140 / 240 28 65 284 300 133 28.5 97 62 71.5
max
/min
max
/min
max
/min
max
/min
max
min
11973 11974220-
65 33 0.3 0.252180 1550 220 240 61.1 66.7 33 34 324 334
56 44 3.3240 1250(1) 930(3) 120(1) 130(3) 33.3(1) 36.1(3) 32(1) 32(3) 314(1) 314(1)
11995 11996220-
24 12 0.18 0.071720 1980 120 100 33.3 27.8 14.5 13.5 142 132
41 <30 2.1240 970(1) 1090(2) 60(1) 50(2) 16.7(1) 13.9(2) 8.9(1) 8.3(2) 87(1) 81(2)
11971 11972220-
22 6 0.1 0.051130 829 118 140 32.8 38.9 22 22 216 216
38 <30 2.9240 594(1) 450(3) 55(1) 67(3) 15.3(1) 18.6(3) 8(1) 8(3) 78(1) 78(3)
mmH2O PaP max
m3/h l/s
V ~
50
Hz
W
Lp dB(A)3 m
kg IP
Vort Press110 LL I - T
Vort Press140 LL I - T
Vort Press240 LL I - T
max
min
max
/min
max
/min
TIM
ER A
max
min
max
/min
max
/min
cl.IIX4
cl.IIX4
cl.IIX4
Vort Press 110 LL I - T
Vort Press 140 LL I - T
Vort Press 240 LL I - T
max
/min
max
/min
continuous operation) with thermalcut-out.
■ Two speed motor.■ IMQ information certifies third
party product data andperformance.
■ Double motor-fan housing,anti-vibration supports andbackdraught shutter for silentoperation.
■ Complies with the CEI 61-28(140/240) and EN 60335-2-80 (110)standards and IPX4 protection.
Design: F. Trabucco & Associati(110) and F. Trabucco and M. Vecchi(140/240).
VORT PRESS® LL FLUSH-MOUNTEDMODELS■ For the ventilation of
medium-sized or largerooms in commercialapplications plusbathrooms/showers/toilets/utilities and kitchens indomestic situations.
■ Six models with or without timers.■ “Intelligent” timer turns the unit on
approximately 40 sec. after theactivation. When switched off, theunit continues to operate at theminimum speed for between 30sec. and 30 min. (depending onthe setting).
■ Motor with ball bearings(guaranteed 30,000 hours of
WALL OR CEILING, FLUSH-MOUNTED CENTRIFUGAL EXTRACTOR FANS, WITH IPX4 SPLASHPROOF PROTECTION, SUITABLE FOR DUCTED INSTALLATION.
Wall-mounted withside extract.
➊ Unobtrusive front grille with support springs which clamp it to the➋ surface, making it suitable for all types of walls and ceilings (maw 65 mm).➌ Metallic filter can be removed and washed (dishwasher safe).➍ Made of rigid synthetic resin to guarantee high durability.➎ On 110 model, the outlet spigot can be changed to a high or low
level spigot.➏ Silicon backdraught shutter on 140 and 240 models to avoid back
flow when unit is turned off.
Wall-mounted with sideextract.
Motor with ball bearings:30,000 hours guaranteedcontinual operation.
False -ceiling-mountedwith side extract.
False-ceiling-mountedwith back extract.
Ceiling-mounted.
Spare Parts■ Metallic anti-dust filter (110: code 1193006023 -
140/240: code 1193006022).
Wiring diagrams shown on page XXVII.(1)Rear air outlet. (2)Side air outlet with high profile. (3)Side air outlet. (4)11971. (5)11971-11974-11995. Conforms with ISO 3744 for noise and pressure levels
Product
Code RpmDelivery
App
rova
ls
Insu
latio
n
Supply and install a Vort Press centrifugal extract fan with integral, silicon backdraught shutter for flush mounting installation in wall or ceiling and ducted applications as manufactured exclusively by Vortice only for Vortice. The fan should have two speed motor and have a performance, on max., in excess of the requirements of the Building Regulations(Document F). The requirements are 15 l/s for Bathrooms/Toilets – 30 l/s for Utilities and 60 l/s for Kitchens (model with a 15 minute overrun timer for internal rooms). It should be tested andcertified as IPX4 (splashproof) with all performance data third party IMQ (BEAB recognised equivalent) verified. The fan should be manufactured from durable, rigid synthetic resin andhave an unobtrusive, spring clip-fix front grille complete with washable metallic filter. The rear spigot should provide a choice of either vertical or horizontal entry (Vort Press 140i and 240i)and be able to accept both the optional high and low profile connectors Vort Press 110i). The motor should be a stainless steel ball bearing, shielded pole motor (30,000-hour guarantee),and include a thermal cut out device. Control options should include: Speed Control and Electronic Humidity Control (using an optional controller) and Intelligent (delay on) Timer.
Back air outlet
Side air outlet with high profile(optional kit)
Back air outlet
Side air outlet
Back air outlet
Side air outlet
Pressure/performance curves
Model Code Products
Electronic thermo-11971 humidistat 12908
Humidity Control11973
SCNR electronic11995
12912 11971 speed controller
11973
SCNRB 11995 electronic 12971 11971 speed controller 11973
False-ceiling/wall 22823 11995 - 11996installation kit
Wall/ceiling 11971 installation 22815 11972 - 11973 kit 11974
High profile 22841 11995 - 11996 connector
Low profile 22842 11995 - 11996connector
Fixed grille 22010 for all products
SCB Kit 22481 11973
Accessories (see also on page 54)
01.DOMESTICO DEF1 30-06-2003 16:43 Pagina 38
LONG LIFE 30.000 h
40
32
24
16
8
0
mmH2OPa
p t
300
200
100
0m3/h
l/sqv
0 20 40
0 50 150100 200 250
60
m3/h
qv
l/s 0
20
16
12
8
4
0
p t
150
100
50
0
10 20
0 25 7550 100
mmH2OPa
125
30
4140
Vort Press LL A B C ∅ D E
110 202 147 30 97 73
220 275 140 28 97 73
➊➋➌
➍
➎
A E
E
B
∅ D
C
110 220
max
min
11967 11968220-
24 12 0.22 0.07 1760 925110(1) 55(1) 16(3) 10(3)
41 <30 1.95
cl.IIX4240 30.6(2) 15.3(2) 157(4) 98(4)
11977 11978 220- 68 35 0.3 0.24 2060 1200 220(1) 120(1) 33(3) 32(3)
55 43 2.3
cl.II
X4240 61.1(2) 33.3(2) 324(4) 314(4)
P maxA
V ~
50
Hz
WLp dB(A)
3 m
kg IP
Vort Press 110 LL
Vort Press 220 LL
max
min
max
min
max
min
max
min
max
min
max
minTIM
ER
(1)m3/h - (2)l/s - (3)mm H2O - (4)Pa
VORT PRESS® LL STANDARD RANGE
Dimensions (mm)
Pressure/performance curves
■ For the ventilation ofmedium-sized or largerooms in commercialapplications plusbathrooms/showers/toilets/utilities and kitchens indomestic situations.
■ Four models with or without timers.■ “Intelligent” timer turns the unit on
for approximately 40 sec. after theactivation. When switched off, theunit continues to operate at theminimum speed for between 30sec. and 30 min. (depending onthe setting).
■ Motor with ball bearings(guaranteed 30,000 hours ofcontinuous operation) with thermalcut-out.
■ Two speed unit.■ IMQ information label certifies
third party product data andperformance.
■ Double motor-fan housing, anti-vibration supports and backdraughtshutter for silent operation.
■ Complies with the CEI 61-28standards and IPX4 protection.
Design: F. Trabucco - M. Vecchi
➊ Front grille.➋ Metallic filter which can be removed and washed (dishwasher safe).➌ Made of rigid synthetic resin to guarantee high durability.➍ 100 mm dia. outlet spigot.➎ Silicon backdraught shutter to avoid back-flow when the unit is turned off.
Ducted installation. Wall or ceilinginstallation.
Motor with ball bearings:30,000 hoursguaranteed continualoperation
Bathroom installation.Kitchen installation.
Wiring diagrams shown on page XXVII.
WALL OR CEILING-MOUNTED CENTRIFUGAL EXTRACTOR FANS, WITH TWO SPEEDS AND IPX4 SPLASHPROOF PROTECTION SUITABLE FOR DUCTED INSTALLATION.
Spare Parts■ Metallic anti-dust filter
(110: code 1193006019 -220: code 1193006021).
Conforms with ISO 3744 for noise and pressure levels
Product
Code
Rpm Delivery Approvals
Insu
latio
n
Accessories on request (description and data on page 54)
Supply and install a Vort Press centrifugal extract fan with integral, silicon backdraught shutter for installation in wall or ceiling and ducted applications asmanufactured exclusively by Vortice only for Vortice. The fan should have two speed motor and have a performance, on max., in excess of therequirements of the Building Regulations (Document F). The requirements are 15l/s for Bathrooms/Toilets – 30 l/s for Utilities and 60 l/s for Kitchens (modelwith a 15 minute overrun timer for internal rooms). It should be tested and certified as IPX4 (splashproof) with all performance data third party IMQ (BEABrecognised equivalent) verified. The fan should be manufactured from durable, rigid synthetic resin and have a clip-fix front grille complete with washable metallic filter. The motor shouldbe a stainless steel ball bearing, shielded pole motor (30,000-hour guarantee), and include a thermal cut out device. Control options should include:Speed Control and Electronic Humidity Control (using an optional controller) and Intelligent (delay on) Timer.
Model Code Products
Electronic thermo-humidistat 12908 11967 - 11977
Humidity Control
SCNR electronic speed controller 12912 11967 - 11977
SCNRB electronic speed controller 12971 11967 - 11977
Fixed grille 22010 for all products
SCB Kit 22481 11967 - 11977
01.DOMESTICO DEF1 30-06-2003 16:44 Pagina 40