volumat line of administration sets

8
Volumat Line of Administration Sets For use with Agilia ® Infusion System

Upload: others

Post on 16-Oct-2021

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Volumat Line of Administration Sets

Volumat Line of Administration SetsFor use with Agilia® Infusion System

Page 2: Volumat Line of Administration Sets

• Silicone pump segment is designed to maintain pumping performance and accuracy up to 96 hrs.

• Color coded connectors to match with pump tubing guides for proper set loading.

• Equipped with SafeClip to protect against unintentional free flow when the pump door is opened.

Silicone pump segment

• The Agilia® volumetric pumps and sets integrate a state-of-the-art pumping mechanism and calibrated pumping segment to aid in accurate delivery of infusions.

• No repositioning required to maintain accuracy +/- 5% from rates 0.1 - 1500 mL/hr.

• A Volumat Line is a dedicated pump set that can be easily converted to a gravity set.

• All Volumat Lines are not made with natural rubber latex and are non-DEHP (PVC free options available).

Volumat Line of Administration Sets

Pumping Segment

• The Occlusivity Check System (OCS) helps protect patients from unintentional free flow at start-up.

See Volumat Line labeling for additional instructions for use Refer to the Agilia Instructions For Use for a list of warnings and precautions associated with the device

The Occlusivity Check System Test

2 3Volumat LineVolumat Line

Page 3: Volumat Line of Administration Sets

Volumat Line Features

Refer to the Agilia Instructions For Use for a list of warnings and precautions associated with the device

4 5Volumat LineVolumat Line

Protective CapCovers the spike

Transparent Drip Chamber (Macro 20 drops/mL or Micro 60 drops/mL)Visual confirmation of fluid flow. User can calculate rate by counting drops.

Pinch Clamp

Flow Stop Cap (blue) Allows priming of fluid without removing the blue end cap. Flow stops once the fluid reaches the filter in the end cap.

DownstreamNeedleless ConnectorUsed to connect additional lines or administer an IV push.

Vented / Non-vented Spike (Convertible piercing pin)When closed, designed for fully collapsible plastic containers or opened to vent for rigid containers and glass bottles for fluid to flow.

Roller Clamp Used to regulate fluid flow while priming the set or to control rate of infusion when using the set for gravity delivery.

Silicone Pump Segment Calibrated silicone pumping segment which enables flow accuracy.

Optional: Back Check Valve Prevents back flow of fluid during a secondary infusion or administration through one of the needle-free ports below it.

Green Connector Alignment with pump tubing guide

SafeClip (Blue) Passive free flow protection. When the pump door is opened the pump automatically clamps the line to prevent unintentional free flow

Luer Lock Connection Secures to IV catheter to prevent unintentional disconnects. Retractable and spin design allows the nurse to connect with minimal manipulation of the IV catheter.

Upstream Needleless Connector Used to access primary line to infuse a secondary medication.

4 Volumat Line

Page 4: Volumat Line of Administration Sets

Please note that a Volumat Line is not made with natural rubber latex or DEHP. All measurements are approximate.

Volumat Line of Administration Sets

6 7Volumat LineVolumat Line

Standard sets

Primary sets

Standard Pump Set with convertible piercing pin, roller clamp, calibrated silicone pumping segment with SafeClip, rotating male luer lock.

PV(mL):Nominal

Length (inch):Drops/mL Tubing ID:

Units/Case:

25 112 20 0.118” 30

M46441360

Standard Set with non-siliconized spike, convertible piercing pin, roller clamp, calibrated silicone pumping segment with SafeClip, rotating male luer lock.

PV(mL):Nominal

Length (inch):Drops/mL Tubing ID:

Units/Case:

25 112 20 0.118” 30

M46441375

Standard Pump Set with convertible piercing pin, roller clamp, calibrated silicone pumping segment with SafeClip, downstream pinch clamp, needle-free port, rotating male luer lock.

PV(mL):Nominal

Length (inch):Drops/mL Tubing ID:

Units/Case:

25 112 20 0.118” 30

M46441960

Standard Set with non-siliconized spike, convertible piercing pin, roller clamp, calibrated silicone pumping segment with SafeClip, downstream pinch clamp, needle-free port, rotating male luer lock.

PV(mL):Nominal

Length (inch):Drops/mL Tubing ID:

Units/Case:

25 112 20 0.118” 30

M46441985

Primary Set with convertible piercing pin, pinch clamp, backcheck valve, needle free port, roller clamp, calibrated silicone pumping segment with SafeClip, downstream pinch clamp, needle-free port, rotating male luer lock.

PV(mL):Nominal

Length (inch):Drops/mL Tubing ID:

Units/Case:

20 81 20 0.118” 30

M46445465

Primary Pump Set with convertible piercing pin, pinch clamp, backcheck valve, needle free port, roller clamp, calibrated silicone pumping segment with SafeClip, downstream pinch clamp, needle-free port, rotating male luer lock.

PV(mL):Nominal

Length (inch):Drops/mL Tubing ID:

Units/Case:

25 112 20 0.118” 30

M46445660

Primary Set with convertible piercing pin, pinch clamp, backcheck valve, needle free port, roller clamp, calibrated silicone pumping segment with SafeClip, downstream pinch clamp, 2 needle-free ports 35” apart, rotating male luer lock.

PV(mL):Nominal

Length (inch):Drops/mL Tubing ID:

Units/Case:

25 112 20 0.118” 30

M46445780

Primary Pump Set with convertible piercing pin, pinch clamp, backcheck valve, needle free port, roller clamp, calibrated silicone pumping segment with SafeClip, downstream pinch clamp, 2 needle-free ports, rotating male luer lock.

PV(mL):Nominal

Length (inch):Drops/mL Tubing ID:

Units/Case:

25 112 20 0.118" 30

M46445690

Page 5: Volumat Line of Administration Sets

Please note that a Volumat Line is not made with natural rubber latex or DEHP. All measurements are approximate.

8 9Volumat LineVolumat Line

Filter sets

- - - - - - - - - - - - - - -

- - - - - - - - - - - - - - -

Burette Set with piercing pin, 150 mL burette, 20 drops/mL, needle free port, roller clamp, calibrated silicone pumping segment with SafeClip, downstream pinch clamp, needle-free port, rotating male luer lock.

PV(mL):Nominal

Length (inch):Drops/mL Tubing ID:

Units/Case:

25 118 20 0.118” 10

M46445260

Burette Set with piercing pin, 150 mL burette, 60 drops/mL, needle free port, roller clamp, calibrated silicone pumping segment with SafeClip, downstream pinch clamp, needle-free port, rotating male luer lock.

PV(mL):Nominal

Length (inch):Drops/mL Tubing ID:

Units/Case:

20 118 60 0.0118/0.098” 10

M46445270

Specialty sets

Standard Pump Set, PVC free with convertible piercing pin, roller clamp, calibrated silicone pumping segment with SafeClip, downstream pinch clamp, needle-free port, rotating male luer lock.

PV(mL):Nominal

Length (inch):Drops/mL Tubing ID:

Units/Case:

25 112 20 0.118” 30

M46443450

Primary Set PVC free with non-siliconized convertible piercing pin, pinch clamp, backcheck valve, needle free port, roller clamp, calibrated silicone pumping segment with SafeClip, downstream pinch clamp, needle-free port, rotating male luer lock.

PV(mL):Nominal

Length (inch):Drops/mL Tubing ID:

Units/Case:

20 81 20 0.118” 30

M46445475

Standard Filter Set with convertible piercing pin, roller clamp, calibrated silicone pumping segment with SafeClip, downstream 1.2 micron filter, pinch clamp, needle-free port, rotating male luer lock.

PV(mL):Nominal

Length (inch):Drops/mL Tubing ID:

Units/Case:

25 114 20 0.118” 30

M46442460

Standard Filter Set PVC free with non-siliconized spike, convertible piercing pin, roller clamp, calibrated silicone pumping segment with SafeClip, downstream 0.2 micron filter, pinch clamp, needle-free port, rotating male luer lock.

PV(mL):Nominal

Length (inch):Drops/mL Tubing ID:

Units/Case:

26 114 20 0.118” 30

M46444175

Standard filter Pump Set PVC free with convertible piercing pin, roller clamp, calibrated silicone pumping segment with SafeClip, downstream 0.2 micron filter, pinch clamp, needle-free port, rotating male luer lock.

PV(mL):Nominal

Length (inch):Drops/mL Tubing ID:

Units/Case:

26 114 20 0.118" 30

M46444160

Burette sets

Primary Filter Pump Set with convertible piercing pin, non-DEHP tubing, pinch clamp, backcheck valve, needle-free port, roller clamp, calibrated silicone pumping segment with SafeClip, downstream 0.2 micron filter, pinch clamp, needle-free port, rotating male luer lock.

PV(mL):Nominal

Length (inch):Drops/mL Tubing ID:

Units/Case:

27 112 20 0.118” 30

M46445860

Page 6: Volumat Line of Administration Sets

Please note that a Volumat Line is not made with natural rubber latex or DEHP. All measurements are approximate.

10 11Volumat LineVolumat Line

Transfusion sets

Transfusion Pump Set with single nonvented spike, upstream 200 micron filter, roller clamp, calibrated silicone pumping segment with SafeClip, rotating male luer lock.

M46442860

Transfusion Pump Set with dual nonvented spikes, 2 roller clamps, upstream 200 micron filter, roller clamp, calibrated silicone pumping segment with SafeClip, downstream pinch clamp, needle free port, rotating male luer lock.

PV(mL):Nominal

Length (inch):Drops/mL Tubing ID:

Units/Case:

30 114 20 0.118" 30

PV(mL):Nominal

Length (inch):Drops/mL Tubing ID:

Units/Case:

25 112 20 0.118" 30

M46443160

Volumat Secondary Set PVC free with non-siliconized spike, convertible piercing pin, roller clamp, rotating male luer lock, Hanger.

PV(mL):Nominal

Length (inch):Drops/mL Tubing ID:

Units/Case:

10.5 27 20 0.118" 40

M77460052

Specialty sets Secondary sets

Primary Pump Set with convertible piercing pin, pinch clamp, backcheck valve, 4 needle free ports, roller clamp, calibrated silicone pumping segment with SafeClip, downstream pinch clamp, needle-free port, rotating male luer lock.

PV(mL):Nominal

Length (inch):Drops/mL Tubing ID:

Units/Case:

30 118 20 0.118" 30

M46445680Volumat Secondary Set with non-siliconized spike, convertible piercing pin, roller clamp, rotating male luer lock, Hanger.

PV(mL):Nominal

Length (inch):Drops/mL Tubing ID:

Units/Case:

12 35 20 0.118" 40

M77460051

Secondary Set with convertible piercing pin, roller clamp, rotating male luer lock, Hanger. PV(mL):

Nominal Length (inch):

Drops/mL Tubing ID:Units/Case:

12 35 20 0.118" 40

M77460030Primary Pump Set with convertible piercing pin, pinch clamp, backcheck valve, 2 needle free ports, roller clamp, calibrated silicone pumping segment with SafeClip, downstream pinch clamp, needle-free port, rotating male luer lock.

PV(mL):Nominal

Length (inch):Drops/mL Tubing ID:

Units/Case:

25 112 20 0.118” 30

M46445670

Page 7: Volumat Line of Administration Sets

Please note that a Volumat Line is not made with natural rubber latex or DEHP. All measurements are approximate.

Open position (allows fluid flow for priming and

gravity use).

The container should be hung between 8”– 32 ” above the pump.

Closed position (stops fluid flow).

Reference Chart

12 13Volumat LineVolumat Line

Push the blue clip to open position.

Use the roller clamp on the administration set to control gravity flow.

The SafeClip is automatically closed when the Agilia door is opened, providing passive free flow protection.

SafeClip

The Volumat Line of administration sets can be used for gravity infusion by opening the SafeClip:

Ensure the roller clamp is in the closed position.

1

2

3

To the patient

Align the fully primed administration set horizontally along the tube guides so that the green connector is on the right, and the SafeClip (blue anti-free-flow clamp) is on the left.

The Volumat Line of administration sets with color-coded connectors aids in loading the pump segment.

Set Loading

1

Insert the green connector into the green slot.

2

Guide the SafeClip (blue clamp) into the blue slot, with the spherical hinge on top.

3

Push the SafeClip to move the spherical hinge into place.

4

Check that the tubing is inserted in the left tube guide.

5

From the container

Green connector

Order Number Description Category

M46441360 VL ST10-0 Standard

M46441375 VL ST10-X0 Standard Non-siliconized spike

M46441960 VL ST02-0 Standard

M46441985 VL ST02-X0 Standard Non-siliconized spike

M46442460 VL PN02-1 Filter (0.2 micron)

M46442860 VL TR00-0 Transfusion

M46443160 VL SP22-0 Transfusion

M46443450 VL SP62-1 Specialty - PVC Free

M46444160 VL ON72-1 FIlter (0.2 micron) PVC Free

M46444175 VL ON72-X1  Filter (0.2 micron) PVC Free, Non-siliconized spike

M46445260 VL PA92-1 Burette (20 gtt)

M46445270 VL PA92-2 Burette (60 gtt)

M46445465 VL PR40-11 Primary - Short

M46445475 VL SP40-11 Specialty - PVC Free, Non-siliconized spike

M46445660 VL PR42-11 Primary

M46445670 VL PR42-21 Specialty Primary (2 upper NC)

M46445680 VL PR42-41 Specialty Primary (4 upper NC)

M46445690 VL PR42-12 Primary

M46445780 VL PR44-12 Primary - (2 lower NC 34” apart)

M46445860 VL PR72-11 Filter (1.2 micron)

M77460030 SL00-0 Secondary

M77460051 VL SL00-X0 Secondary - Non-siliconized spike

M77460052 VL SL00-XP Secondary - PVC Free, Non-siliconized spike

Page 8: Volumat Line of Administration Sets

Fresenius Kabi USAThree Corporate DriveLake Zurich, Illinois 60047855-FK-INFUSION855-354-6387www.fresenius-kabi.us/agilia

Agilia is a registered trademark of Fresenius Kabi AG.

0002-VL-01-10/18