Page 1: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

VOLTEX® & VOLTEX® DSBENTONITE GEOTEXTILE WATERPROOFING SYSTEM FOR CAST-IN-PLACE CONCRETE APPLICATIONS

PRODUCT MANUAL

www.cetco.com

Page 2: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

PRODUCT MANUAL

- 2 -North America: +1 847.851.1800 | +1 800.527.9948 | www.cetco.com

VOLTEX® & VOLTEX® DSBENTONITE GEOTEXTILE WATERPROOFING FOR CAST-IN-PLACE CONCRETE APPLICATIONS

CONTENTSWHAT IS SODIUM BENTONITE?PRODUCT DESCRIPTIONASSOCIATED SYSTEM PRODUCTSACCESSORIESLIMITATIONS

INSTALLATION GUIDELINESSECTION 1: UNDERSLAB INSTALLATION 1.1 Substrate Preparation 1.2 Installation 1.3 Pile Caps & Grade Beams 1.4 Slab Penetrations 1.5 Elevator Pits 1.6EdgeofSlab,BackfilledWalls 1.7EdgeofSlab,PropertyLineWalls SECTION 2: PROPERTY LINE CONSTRUCTION 2.1 Property Line Installation Guidelines 2.2 Soldier Pile & Lagging 2.3MetalSheetPilingRetainingWall 2.4 Earth Formed Shotcrete Retention 2.5AugerCastCaissonRetentionWall SECTION 3: BACKFILLED WALLS 3.1 Surface Preparation 3.2 Installation 3.3BackfilledWallPenetrations 3.4 Terminations 3.5MasonryBlockWalls SECTION 4: SPECIAL CONDITIONS 4.1 Precast Concrete Construction 4.2 Contaminated Conditions

THIS MANUAL CONTAINS THE INSTALLATION GUIDE-LINES FOR THE VOLTEX AND VOLTEX DS WATER-PROOFING SYSTEM FOR CAST-IN-PLACE CONCRETE APPLICATIONS, INCLUDING UNDERSLAB, PROPERTY LINE WALLS, AND BACKFILLED WALLS. THIS MANUAL DOES NOT COVER SHOTCRETE, MASONRY BLOCK, OR PRECAST CONCRETE APPLICATIONS. FOR APPLI-CATIONS NOT COVERED IN THIS MANUAL, CONTACT CETCO FOR SPECIFIC INSTALLATION GUIDELINES. BEFORE INSTALLATION, READ THIS MANUAL TO GAIN FAMILIARITY WITH SPECIFIC PROCEDURES AND AP-PLICATIONS. IN THIS MANUAL THE PRODUCT NAME “VOLTEX” IS USED GENERICALLY FOR ALL VOLTEX PRODUCT TYPES.

WHAT IS SODIUM BENTONITE?Sodium bentonite is a non-toxic mineral of volcanic origin found exten-sively in the Black Hills region of North America. Bentonite is specially processed by CETCO to achieve the highest possible performance for allofourwaterproofingproducts.CETCOalsomanufacturersacontami-nant resistant bentonite to assure optimum performance in moderate saline or contaminated water.

Bentonite prevents water intrusion by forming a dense monolithic mem-brane upon contact with water. The specially processed bentonite ex-pandsunderconfinement,forminganimperviousmembranethatwillbe maintained for the life of the structure.

PRODUCT DESCRIPTIONVOLTEX isahighly effectivewaterproofing composite comprisedof twopolypropylene geotextiles and sodium bentonite. The two geotextiles are in-terlocked by a patented needlepunching process which encapsulates and confinesthebentonite.VOLTEXDS® integrates a polymer liner bonded to the outside surface of the nonwoven geotextile. The polymer liner provides extremely low permeabilities for water vapor transmission.

Figure1–CrosssectionillustrationofVOLTEXwaterproofingmembranemechanicallybondedtoconcrete

Concrete

Needlepunched geotextilefibers

Granular sodium bentonite

Nonwoven geotextile

VOLTEX forms a continuous mechanical bond to concrete. This bond is created when VOLTEX’s strong geotextilefibersareencapsulated by poured concrete as shown in the illustration

Wovengeotextile

Page 3: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

www.cetco.com

Installation of VOLTEX is fast and easy. Simply position the product into place and fasten. VOLTEX can be installed on green concrete, in virtu-ally any weather, without the need for primers or adhesives. VOLTEX can be easily cut on site to form around corners and penetrations. The result is always a consistent self-sealing membrane.

DURABILITYThe VOLCLAY® sodium bentonite in VOLTEX is uniformly encapsulated between two high-strength woven and non-woven geotextiles. CETCO’s state-of-the-art needlepunching process interlocks the geotextiles, preventing the displacement of bentonite prior to, during, and after in-stallation. The geotextiles provide superior protection from inclement weather and construction-related damage, without requiring to use a protection course.

SUPERIOR ADHESIONWhenconcreteispouredagainstVOLTEX,atenaciousmechanicalbondis created with VOLTEX’s high strength geotextile. Independent labora-torytestingconductedinaccordancewithASTMD903(mod.)(PeelAd-hesiontoConcrete),yieldsanaverageadhesionvalueof2.6kN/m(15lbs/in).ThemechanicalbondwillholdVOLTEXinintimatecontactwiththe concrete should any ground settlement occur, thereby preventing watermigrationbetweenthewaterproofingandtheconcrete.

COST EFFECTIVE AND TIME EFFICIENTVOLTEX is designed to be installed on a properly prepared subgrade, withouttheneedtopouraworkingslab.Theproduct’sinherentflexibil-ity allows for easy installation on irregular surfaces and rough property line forming. VOLTEX can be installed as soon as the forms are stripped; there is no waiting for the concrete to cure.

ASSOCIATED SYSTEM PRODUCTSWATERSTOP-RX® – expanding concrete joint waterstop used around penetrations and applicable concrete joints. Swells upon hydration.AQUADRAIN® – foundation drainage composite consisting of a molded profilecoreandafilterfabric.Includessheetdrainageandbasedraincollection.

ACCESSORIESBENTOSEAL® – trowel grade mastic used to detail around penetrations, corner transitions and terminations. CETSEAL – single-component polyether general sealant and adhesive. HYDROBAR TUBES®–watersolublefilmtubingfilledwithactivegranu-lar material.WATERSTOPPAGE® – active granular material used at detail areas that require additional protection.SEAMTAPE® – premium tape used to seal overlapped membrane edges ofVOLTEXDS.AKWASWELL® – caulk grade hydrophilic waterstop.

TERMINATION BAR–Min.25mm(1”)widealuminumorstainlesssteelbarwithpre-punchedholeson300mm(12”)centeringforfastening.

CEMENTITIOUS BOARD – 12 mm (1/2”) thick cementitious wallboardforprotectionofwaterproofingduringtheremovalofsteelsoldierpile cap and top lagging boards.

ENVIROSHEET – self-adheringflashingmembraneusedforgradeandthru-wallflashing.

TB-BOOT – pre-formed, single piece cover for tie-back heads and soil nails.Threesizesavailable:TB-6SN,TB-8&TB-10.

LIMITATIONSVOLTEX should only be installed after substrate preparation has been properly completed and is suitable to receive the waterproof-ing system. Concrete work should use conventional cast-in-place formsthatproduceasmoothsurface.Donotusestay-in-placecon-crete forming; use removeable forming products only.

VOLTEX is designed for below-grade waterproofing applicationswheretheproductisproperlyconfined.VOLTEXproductsshouldnotbe installed in standing water or over ice. If ground water contains strongacids,alkalies,orisofaconductivityof2,500μmhos/cmorgreater, water samples should be submitted to the manufacturer for compatibility testing. Ultraseal may be required if contaminated ground water or saltwater conditions exist.

VOLTEX isdesigned foruseunder reinforcedconcrete slabs100mm (4”) thickor greater ona compactedearth/gravel substrate.VOLTEXrequiresaminimum150mm(6”)thickreinforcedconcreteslab if installed over a mud slab. VOLTEX is not designed for split-slab plaza deck construction.

VOLTEX is not designed to waterproof expansion joints. Do not use VOLTEX on masonry block foundation walls. Con-sult CETCO for special installation guidelines that apply to shotcrete and precast concrete construction.

In this manual, the product name “VOLTEX” is used generi-cally in the installation and application guidelines for the applicable products: VOLTEX, VOLTEX CR, VOLTEX DS and VOLTEX DSCR. Refer to the table on the back page for prod-uct descriptions and roll sizes. Illustrations are not shown to scale.

Page 4: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

PRODUCT MANUAL

- 4 -North America: +1 847.851.1800 | +1 800.527.9948 | www.cetco.com

VOLTEX® & VOLTEX® DSBENTONITE GEOTEXTILE WATERPROOFING FOR CAST-IN-PLACE CONCRETE APPLICATIONS

INSTALLATION GUIDELINESBefore installing VOLTEX read this installation manual to gain familiarity withspecificproceduresandapplications.Forapplicationsnotcoveredinthismanual,contactCETCOforspecificinstallationguidelines.

VOLTEXisengineeredforuseunderreinforcedconcreteslabs100mm(4”) thickorgreateronacompactedearth/gravel substrate.VOLTEXrequiresaminimum150mm(6”)thickreinforcedconcreteslabifin-stalledoveramudslab.VOLTEXCRorVOLTEXDSCRisusedincontami-nated conditions as determined by a CETCO water sample test.

For hydrostatic conditions, VOLTEX should be installed under foot-ings and grade beams as shown in Figures 1.6, 1.7 and 1.8. For non-hydrostatic conditions, VOLTEX should be installed around footings and gradebeamsasshowninFigures1.9,1.10and1.11.

Prior to installing VOLTEX the substrate must be properly prepared. Complete all required elevator pit, sump pit, grade beam and piling work prior to installing VOLTEX under main slab area. These areas must becorrectlytiedintotheunderslabwaterproofingtoformamonolithicseal.

1.1 SUBSTRATE PREPARATIONSubstrate may be concrete, earth, sand, or crushed stone. Earth and sand substrates should be compacted to aminimum85%ModifiedProctordensity.Crushedstoneshouldbenolargerthan19mm(3/4”)insize.Substrateshouldbesmoothandwithoutsharpdeflectionsorpockets.

1.2 INSTALLATIONInstallVOLTEXorVOLTEXDSovertheproperlypreparedsubstratewiththedarkgray(woven)geotextilesideup.Overlapalladjoiningedgesaminimumof100mm(4”)andstaggersheetendsaminimumof300mm(12”)(Figure1.1).Nailorstapleedgestogetherasrequiredtopre-ventanydisplacementbeforeandduringconcreteplacement(Figure1.2).

Whentheslabispouredinsections,VOLTEXshouldextendaminimum300mm(12”)beyondtheslabedge(Figure1.3).ThisenablesVOLTEXto be properly overlapped for subsequent slab section pours. WATER-STOP-RX should be installed in all applicable slab construction joints (Figure1.3).

SECTION 1 UNDERSLAB INSTALLATION

DARK GRAY (WOVEN) GEOTEXTILE SIDE UP

Overlap 100mm(4")min.

Figure 1.2 – Secure overlaps together with fasteners

Figure 1.3 – Extend VOLTEX a minimum 300mm(12”) beyond slab edge. Install WATERSTOP-RX in joint

Figure 1.1 – Overlap edges 100mm(4”)withseamsstaggered300mm(12”)

VOLTEX

Overlap 100mm (4")Min.

Stagger300mm(12”)

Reinforced concrete slab

300mm(12”)min VOLTEX

WATERSTOP-RX min.75mm(3”)coverage

Page 5: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

www.cetco.com

WATERSTOP-RX 75mm(3”)min.coverage

Reinforced concrete slab a minimum100mm(4”)thick

VOLTEX

Compacted Substrate

DARK GRAY (WOVEN) GEOTEXTILE SIDE UP

Figure1.4–VOLTEXinstalleddirectlyovercompactedearth/gravelsubstraterequiresaminimum100mm(4”)slab

Reinforced concrete slab a minimum150mm(6”)thick

VOLTEX

Compacted Substrate

Concrete mud slab

Figure1.5–VOLTEXinstalledoveramudslabrequiresaminimum150mm(6”)thickreinforcedslab

WATERSTOP-RX 75mm(3")min.coverage

DARK GRAY (WOVEN) GEOTEXTILE SIDE UP

Page 6: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

PRODUCT MANUAL

- 6 -North America: +1 847.851.1800 | +1 800.527.9948 | www.cetco.com

VOLTEX® & VOLTEX® DSBENTONITE GEOTEXTILE WATERPROOFING FOR CAST-IN-PLACE CONCRETE APPLICATIONS

HYDROSTATIC CONDITIONS NON-HYDROSTATIC CONDITIONS

VOLTEX

VOLTEX

Hydrobar Tube

Figure1.6–Slabonfootingdetail(hydrostatic)

VOLTEX

BENTOSEAL

Hydrobar Tube

VOLTEX

Mud slab

Figure1.7–Raisedslabdetailwithmudslab(hydrostatic)

VOLTEX

VOLTEX

Figure1.8–Flushslabdetailpropertylinewall(hydrostatic)

VOLTEX

Hydrobar Tube

Figure1.9–Slabonfootingdetail(non-hydrostatic)

VOLTEX

BENTOSEAL

VOLTEX

Mud slab

Figure1.10–Raisedslabdetailwithmudslab(non-hydrostatic)

VOLTEX

Term Bar & BENTOSEAL

300mm (12”)

Figure1.11–Flushslabdetailbackfilledwall(non-hydrostatic)

WATERSTOP-RX 75mm(3")min.coverage

WATERSTOP-RX 75mm(3”)min.coverage

WATERSTOP-RX 75mm(3”)min.coverage WATERSTOP-RX

75mm(3”)min.coverage

WATERSTOP-RX 75mm(3”)min.coverage

WATERSTOP-RX 75mm(3”)min.coverage

Term bar and BENTOSEAL

Page 7: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

www.cetco.com

1.3 PILE CAPS AND GRADE BEAMSVOLTEX is typically not installed over pile caps but cut to fit tightlyaroundpilecaps.Thenapplyaminimum19mm(3/4”) thickfilletofBENTOSEALatintersectionofVOLTEXandthepiling(Figure1.12)withWaterstoppageunderVOLTEXat thepilingedge.BENTOSEAL should extendontoVOLTEXandpilingaminimumof50mm(2”)at19mm(3/4”)thickness.WATERSTOP-RX should be installed on top surface of pilecaparoundreinforcingsteel(Figure1.12).

Detail gradebeams thesameaspilecaps (Figure1.14)withanon-hydrostatic condition. For hydrostatic conditions, VOLTEX should be in-stalledundertheentiregradebeam(Figure1.15).Linethegradebeamformwork with VOLTEX prior to placement of reinforcing steel. Leave a minimum300mm(12”)ofVOLTEXat the topof the formto tie intobelowslabwaterproofing.

Figure1.12–PileCapDetail(Hydrostaticcondition)

Figure1.13–PileCapDetail(Non-hydrostaticcondition)

Figure1.14–GradeBeam(Non-hydrostaticcondition) Figure1.15–GradeBeam(Hydrostaticcondition)

WATERSTOP-RX

Concrete pile

BENTOSEAL

VOLTEX

Waterstoppage

WATERSTOP-RX

Metal I-beam

VOLTEX

WATERSTOP-RX

50mm(2”)thickfilletofBENTOSEAL

GranularWaterstoppage

WATERSTOP-RX Waterstoppage

VOLTEX

BENTOSEAL

Pile cap

BENTOSEAL

Pile

WATERSTOP-RX Reinforcing steel BENTOSEAL

VOLTEX

Grade beam

50mm(2”)thick filletof Waterstoppage

Grade beam

Reinforcing steelWATERSTOP-RX

VOLTEX

Page 8: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

PRODUCT MANUAL

- 8 -North America: +1 847.851.1800 | +1 800.527.9948 | www.cetco.com

VOLTEX® & VOLTEX® DSBENTONITE GEOTEXTILE WATERPROOFING FOR CAST-IN-PLACE CONCRETE APPLICATIONS

1.4 SLAB PENETRATIONSCutVOLTEX tocloselyfitaroundpenetrations (Figure1.16).Trowelaminimum19mm(3/4”)thickfilletofBENTOSEAL around the penetra-tiontocompletelyfillanyvoidareabetweenVOLTEXandthepenetra-tion(Figure1.17).TheBENTOSEAL should extend up the penetration about38mm(1–1/2”)andextendontoVOLTEX.Inareaswheremulti-ple penetrations are close together, it may be impractical to cut VOLTEX

tofitaroundeachpenetration.PourWaterstoppage,granularbenton-ite,aminimum6mm(1/4”)thickaroundthepenetrationscoveringtheentiresubstratearea.Withgravelsubstrate,installminimum200mm(8”) collar of VOLTEX around penetration prior to placing waterstop-page. Then apply a thick layer of BENTOSEAL around each penetration asdetailed(Figure1.19).

Figure 1.17 – BENTOSEAL troweled around penetrations Figure 1.18 – Slab penetration cross section detail

Figure1.19–Multiplepipepenetrations.TrowelBENTOSEAL around pipes and covering area between the pipes

VOLTEX

Pipe

BENTOSEAL

DARK GRAY (WOVEN) GEOTEXTILE SIDE UP

VOLTEX

Waterstoppage

BENTOSEAL

WATERSTOP-RX 75mm(3")min.coverage Pipe

Mud Slab Substrate Compacted Earth or Gravel Substrate

Mud slab

WATERSTOP-RX

BENTOSEAL

Continue VOLTEX between pipes VOLTEX

WaterstoppageMud slab substrate

Continue VOLTEX between pipes

WATERSTOP-RX

BENTOSEAL

Gravel substrate

VOLTEX collar Waterstoppage

Page 9: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

www.cetco.com

1.5 ELEVATOR PITSVOLTEX should be placed on vertical surfaces and on the substrate be-lowtheslabtoformacontinuousenvelopearoundtheelevatorpit(Fig-ure1.20).Iftheverticalsoilcutissmoothandstable,VOLTEXmaybe

installed directly against the soil. Contain unstable soils with a retaining wall. InstallVOLTEXdirectlyagainsttheretainingwall.Duetovariouselevatorpistonplungerdesigns,consultCETCOforspecificinstallationand detailing for piston plungers that penetrate the pit slab.

Figure1.20–VOLTEXunderelevatorpitslabandonexcavationcutwalls

1.6 EDGE OF SLAB, BACKFILLED WALLSWhen the installation reaches the outer edge of the slab, continueVOLTEXuptothetopedgeoftheformsinsidesurface(Figure1.21)orextendtheVOLTEXsheetoutthetopoftheformaminimumof300mm(12”)(Figure1.22).Attheslabcorner,VOLTEXshouldremainincontactwith the substrate and the inside surface of the concrete form.

When the slab edge form is removed, any undamaged portion ofVOLTEX extended outside the form should be positioned and secured

tothetopoftheconcretefooting.Damagedmaterialoutsidetheformshould be cut off and disposed of. Overlap the secured VOLTEX edge ontopofthefootingaminimum150mm(6”)withthesucceedingwallwaterproofing.InstallHydrobarTubesatwall-to-footingcornerpriortoinstallingoverlappingwallwaterproofing.

WATERSTOP-RXshouldbeinstalledintheperimeterwall/slabintersec-tion joint as illustrated in Figure 1.23.

Figure 1.21 – VOLTEX turned up and secured at top of concrete form Figure 1.22 – Extra tail of VOLTEX extended out of form and later cut off after concrete pour

300mm(12”) min

VOLTEX

Compacted substrate

VOLTEX VOLTEX secured to top of form before concrete pour

Slab edge form

Compacted substrate

VOLTEX

Extra tail of VOLTEX extended out of form. Cut off damaged areas before installing VOLTEX overlap

Slab edge form

Compacted substrate

WATERSTOP-RX 75mmmin.(3”)coverage

Page 10: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

PRODUCT MANUAL

- 10 -North America: +1 847.851.1800 | +1 800.527.9948 | www.cetco.com

VOLTEX® & VOLTEX® DSBENTONITE GEOTEXTILE WATERPROOFING FOR CAST-IN-PLACE CONCRETE APPLICATIONS

1.7 EDGE OF SLAB, PROPERTY LINE CONSTRUCTIONWherepropertylineretainingwalls,suchassoldierpileandlagging,areused as the outside form, continue the underslab VOLTEX installation uptheretainingwallaminimum300mm(12”)abovethetopedgeoftheslaborfooting(Figure1.23).Theextra300mm(12”)sheetexten-sion is very important since there is no access to the outer edge of the footing after it is poured.

Slab to Wall Corner Transition:InstallVOLTEXorVOLTEXDSsheethorizontallyoriented(darkgraywovengeotextilefacinginstaller)withaminimum300mm(12”)ofthesheetextendingoutontothehorizontalsubstrate.Thetopedgeofthesheetmustextendaminimum300mm(12”)abovethefinishedslabsurface.SecureVOLTEXsheettolaggingwall with washer-head fastenermaximum 600mm (24”) on center.OverlapedgesofadjacentVOLTEXsheetsaminimum100mm(4”).

Iftheslabthicknessisgreaterthan600mm(24”),installasecondfullsheetorcutstripofVOLTEX,horizontallyoriented,tomeetthe300mm(12”)requirementabovetheslab.Overlaptopedgeofprevioussheetandedgesofadjacentsheetsaminimum100mm(4”).

Base Wall Course: InstallfirstVOLTEXsheetcourseontheshoringwallhorizontallyoriented (darkgreywovengeotextile facing installer)over the corner transition sheet, with the bottom edge extending down to the wall/slab transition corner as shown in Figure 1.23. SecureVOLTEX sheet to lagging wall with washer-head fasteners maximum 600mm(24”)oncenter.OverlapedgesofadjacentVOLTEXsheetsaminimum100mm(4”).

Install underslab VOLTEX membrane extending to corner transition, overlappingthe300mm(12”)sheettailofthecornertransitionsheetinstalledatthewallbase.Securecorneredgewithfasteners300mm(12”)oncenter.

Formetalsheetpilingshoringwalls,firstinstalltheVOLTEXcornertran-sition sheet horizontally oriented with the bottom edge extending mini-mum300mm(12”)outontothesubstrate.Cutthebottomedgeofthecorner transition sheet at piling transition angles to allow the bottom edgetolayflatontothesubstrate.Pour38mm(11/2")continuouscantofWaterstoppagealongbaseof shoringwall. Then install underslabVOLTEXsheetcuttofitcontoursofmetalsheetpiling.Finally,installthebaseshoringwallVOLTEXsheet(horizontallyoriented)overlappingthecorner transition sheet.

Figure1.23–SLAB-TO-WALLTRANSITION–VOLTEXcornertransitionsheetshouldextendpasttheheightofthetopofthefinishedslablevelaminimum300mm(12”)andextendundertheslab300mm(12”)

Figure 1.24 – AQUADRAIN100BDDISCHARGEPIPE–ConnectAQUAD-RAIN100BDtowaterdischargepipesusing100BDaccessorycon-nections

VOLTEX under slabVOLTEX transition sheet at corner in-stalled horizontally oriented

Cast-in-place concrete wall

VOLTEX base course installed horizontally oriented

Woodlagging

300mm (12”)min

VOLTEX base course installed horizontally oriented

AQUADRAIN SheetDrain

Woodlagging

300mm (12”)min

AQUADRAIN100BDbasedrainconnected to discharge pipes

VOLTEX transition sheet at corner installed horizontally oriented

VOLTEX

DischargePipe

WATERSTOP-RX 75mm(3")min.coverage

WATERSTOP-RX 75mm(3”)min.coverage

300mm(12”)BENTOSEAL

Page 11: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

www.cetco.com

The use of construction techniques described in this section allow the exterior building dimensions to coincide with the property line, thereby maximizinguseofavailablelandforbuilding.VOLTEX/VOLTEXDShasbeen proven to be one of the most effective and widely used means forwaterproofingpropertylineconstruction.Cast-in-placepropertylineconstruction methods include soldier pile & lagging, metal sheet piling, earth formed shotcrete retention walls, and auger cast caisson walls.

For all property line construction methods, VOLTEX is installed to the shoring wall prior to concrete placement.Install VOLTEX or VOLTEX DS with the dark grey (woven) geotextile inward, facing the installer, away from the shoring wall. Refer to each applicable construction method in Section 2 for specific sub-strate preparation and detailing installation guidelines.

AQUADRAINsheetand100BDbasedraincompositesystemshouldbeconnectedtoanoperativewaterdischargesystem(sumppumporgrav-itytodaylightdischarge).

Protectbentonitewaterproofingproductsfromhydratingbeforemate-rialiscontainedwithconcreteorbackfill.Afteranyprecipitation,stand-ingwatershouldbepumpedoffwaterproofingassoonaspossible.

Shoring Wall: Excavation work should provide shoring wall in good condition to receive waterproofing system. Wood lagging shoringshouldextendtothelowestlevelofthewaterproofinginstallationwithanyvoidsorcavitiesexteriorofthelaggingfilledwithcompactedsoilorcementitiousgrout.Voidsorcavitiesattie-backsshouldbefilledwithgrout or compacted soil prior to VOLTEX installation. Interior surface of lagging timbers should be monolithic and tight together with gaps less than25mm(1”).Gapsinexcessof25mm(1”)shouldbecompletelyfilledwithcementitiousgroutorothersolidmaterial.

Cut rock excavations and concrete auger cast caisson retaining walls must be sufficiently planar. Typically a shotcrete or grout layer is re-quired to provide acceptable surface to install VOLTEX.

Employconstructionmethodstostopwaterflowingthroughshoringwallpriortowaterproofinginstallation.Ifonlywaterseepage,installpolyeth-ylene sheeting over the seepage area prior to installing VOLTEX. Poly-ethylene sheeting should extend from seepage elevation to base of wall toprotectentirewaterproofinginstallationatthatarea.

SECTION 2 PROPERTY LINE CONSTRUCTION

Figure1.25–RAISEDSLABCONDITION–ConnectAQUADRAIN100BDtowaterdischargepipesusing100BDaccessoryconnectors

Figure 1.26 – Metal sheet piling to slab transition detail

Cast-in-place concrete wall

AQUADRAIN

VOLTEXWood lagging

Hydrobar tube

VOLTEX

Dischargepipe

AQUADRAIN100BDbasedrainconnectedtodischarge pipes

VOLTEX underslab

300mm(12”)min.

Waterstoppagecantin corner over VOLTEX corner transition sheet

Metal sheetpiling

VOLTEX base layer horizontally oriented

WATERSTOP-RX 75mm(3”)min.coverage

WATERSTOP-RX 75mm(3”)min.coverage

BENTOSEAL

Retained earth

VOLTEX corner transition sheet horizontally oriented(installfirst)

VOLTEX corner transition sheet horizontally oriented(slicedto contour sheet piling)

VOLTEX cut to fitcontoursofsheet pilesMud slab

INSTALL VOLTEX OR VOLTEX DS WITH DARK GRAY (WOVEN) GEOTEXTILE SIDE FACING INSTALLER

Page 12: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

PRODUCT MANUAL

- 12 -North America: +1 847.851.1800 | +1 800.527.9948 | www.cetco.com

VOLTEX® & VOLTEX® DSBENTONITE GEOTEXTILE WATERPROOFING FOR CAST-IN-PLACE CONCRETE APPLICATIONS

2.1 PROPERTY LINE WALL INSTALLATION GUIDELINESAfter the slab-to-wall corner transition sheet and bottom wall sheet coursehavebeen installedperSection1.7Page10,VOLTEXsheetscan be installed either vertically or horizontally oriented. Fasten the VOLTEX intopositionwithwasher-head fastenersmaximum600mm(24”)oncenteraroundthesheetedge.InstallsucceedingVOLTEXsheetoverlappingtheprevioussheetedge100mm(4”). (Note:Shingle lapseams so that the bottom edge of the upper sheet is over the lower sheetstopedge).

Continueinstallationupwalluntilgradedetail,orasspecified,stagger-ingallsheetendsofadjacentrollsaminimum300mm(12”).Donotallow sheet overlap joints to occur at same elevation as concrete cold joints. Plan by chalk lining the location of construction joints.

Penetrations: Install a cut collar of VOLTEX tightly around the penetra-tion;extendingaminimum300mm(12”)radius.ApplyBENTOSEAL over VOLTEX collar around penetration; extending BENTOSEAL a minimum 75mm(3”)radiusat6mm(1/4”)thickness.TheninstallmaincourseofVOLTEX membrane tightly around the penetration. Finally, detail around penetrationwith19mm(3/4”)thickcantofBENTOSEAL.Withsleevedpipes,theconcreteworkshouldincludefillingthegapbetweenthepipeand the sleeve with non-shrink cementitious grout, mechanical seal by others and install WATERSTOP-RX to outside of sleeve.

Tie-Back Covers:SelectappropriatesizeTB-Boottofitovertie-backplate and allow proper cast-in-place concrete coverage per project re-quirements. TB-Boot should fit over entire tie-backheadwithout thetie-back plate or cables in direct contact with the TB-Boot. Prior to TB-Bootinstallation,fillvoidsinretentionwallsubstrateandtie-backheadassemblywithspray foam (min20psi)ornon-shrinkgrout.Fornon-hydrostatic conditions, install and secure AQUADRAIN drainage com-posite course per manufacturer’s guidelines to soil retention wall prior to installing TB-Boot. For hydrostatic conditions, install TB-Boot prior toVOLTEXmembrane.Withsoldierpiles,strippileswithwaterproofingmembrane prior to TB-Boot placement.

Fill pre-formed shape of TB-Boot with 2-part urethane spray foam (min20PSI)andplaceovertie-backheadbeforefoamsetsup.Se-cure TB-Boot to soil retention system using washer head fasteners alongtheoutsideedgeoftheflatbase.Apply6mm(1/4”)thickbyminimum75mm(3”)widecontinuousringofBENTOSEAL onto the flatbasejustoutsideofthe12mm(1/2”)raisedcollar.Install4-ftby4-ftpieceofVOLTEX(withprecutholeincentertofittightaroundthe12mm(1/2”)raisedcollar)overtheentireflatbasewithoutsideedges fastened to the retaining wall. Secure inside VOLTEX edge around raised collar with washer-head fasteners that pass through the BENTOSEALring;typicalfastenerspacing150mm(6”).Donotinstall fasteners or puncture TB-Boot inside of the 12mm (1/2”)raised collar. Apply counter flashing ofBENTOSEAL along VOLTEX sheet edge around raised collar. Then install VOLTEX field sheetoverlappingoutermembraneedgeminimum100mm(4”).

Figure 2.1 – WALL PENETRATION – Cut and secure VOLTEX tightlyaround penetrations and then apply BENTOSEAL 19mm (3/4”) ringaroundpenetrationandextendovermembraneaminimum75mm(3”)radiusatminimum6mm(1/4”)thickness

Figure2.2–SLEEVEDWALLPENETRATION–Cut and secure VOLTEX tightly around penetrations and then apply BENTOSEAL19mm(3/4”)ringaroundpenetrationandextendovermembraneamin.75mm(3”)

300mm (12”)min

Woodlagging

300mm(12")VOLTEXcol-lar around pipe penetration

19mm(3/4")BENTOSEAL cant

WATERSTOP-RX

Pipe

Cast-in-place concrete wall

VOLTEX

AQUADRAINSheetDrain

300mm (12”)min

Woodlagging

300mm(12")VOLTEXcol-lar around pipe penetration

19mm(3/4")BENTOSEAL cant

WATERSTOP-RX

Pipe

VOLTEX

AQUADRAIN Sheet Drain

Pipesleeve,filledwithnon-shrink grout

Cast-in-place concrete wall

BENTOSEAL ring 6mmx75mm(1/4”x3")min

BENTOSEAL ring 1/4"x3"min

Mechanical seal by others

Page 13: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

www.cetco.com

Soldier Pile Stripping: Install a strip of VOLTEX over all soldier piles with raised lagging hanger bolts, form tie rods, or other irregular sur-face.VOLTEXstripshouldextendaminimum150mm(6”)tobothsidesof the piling. Apply BENTOSEAL6mmx50mm(1/4”x2”)toVOLTEXstripsurfacealongbothedgesofeachsoldierpile(Figure2.9).

Cementitious Board: Prior to installing VOLTEX/VOLTEXDS to fin-ishedgrade, install12mm(1/2”)thickcementitiouswallboardcen-teredoversteelsoldierpilefromfinishedgradeelevationtospecifieddepth that the top of steel soldier pile and wood lagging will be removed (Figure2.13).

Grade Termination:TerminateVOLTEXmembrane300mm(12”)be-lowfinishedgradeelevationwithwasher-headfastenersmaximum300mm(12”)oncenter.InstallENVIROSHEETflashingtoprimedconcretesubstrate with bottom edge overlapping top edge of VOLTEX membrane minimum100mm(4”).Overlapallrollendsaminimum100mm(4”)toformacontinuousflashing.Heightofflashingshallbeperprojectde-tailsandspecifications.Installarigidterminationbaralongtopedgeof

ENVIROSHEET;fastenedmaximum300mm(12”)oncenter.Completegrade termination detail with tooled bead of CETSEAL along the top edge,atallpenetrationsthroughtheflashing,andallexposedoverlapseams.

Where lagging timbers and the topendof steel soldier piles are re-moved, repair anywaterproofingdamagedby theexcavationand re-moval of the retention wall system. Secure all excavated VOLTEX over-lap seams with washer-head fastenersmaximum 600mm (24”) oncenter;withVOLTEXDSalsoapplySeamtapecenteredalongoverlapseams.Backfillshallbeplacedandcompactedtominimum85%Modi-fiedProctordensitypromptlyafterwaterproofing installation.Backfillshouldconsistofcompactablesoilorangularaggregate19mm(3/4”)or less) freeofdebris,sharpobjects,andstones larger than19mm(3/4”).Seeterminationdetailsfigures3.11and3.12,page22.

Figure2.3:TIE-BACKDETAIL–InstallTB-Bootcenteredovertie-backthen install main course of VOLTEX with BENTOSEALdetailing.Donotfasten boot inside of raised collar around center formed area

Shoring wall

VOLTEX

AQUADRAIN sheet drain

2-part urethane expanding spray foam (min.20PSI)

Soldier pile

Fastener

Use spray foamtofillall voids behind tie-back

Donotfasten boot inside of raised collar

Tie-back head with cables

CETCO pre-formed TB-Boot

BENTOSEAL 6 mm X 75 mm (1/4”x3”)min VOLTEX

Field Sheet

Concrete wall

Fastener

Raised collar

Figure2.3a:TIE-BACKDETAIL–InstallTB-Bootcenteredovertie-backthen install VOLTEX with BENTOSEALdetailing.Donotfastenbootin-side of raised collar around center formed area

Shoring wallSoldier pileFastener

VOLTEX pile strip

VOLTEX

Raised collar

TB-Boot

Fastener

Soldier pile

VOLTEXfieldsheet

Use spray foamtofillall voids behind tie-back

Donotfasten boot inside of raised collar

VOLTEX pile strip

VOLTEX pile strip

Tie-back head with cables

CETCO pre-formed TB-Boot

2-part urethane expanding spray foam (min.20PSI)

VOLTEXfieldsheet

BENTOSEAL 6 mm X 75 mm (1/4”x3”)min

NON-HYDROSTATIC CONDITIONS HYDROSTATIC CONDITIONS

BENTOSEAL

Soldier pile

AQUADRAIN

BENTOSEAL

BENTOSEAL

BENTOSEAL

Page 14: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

PRODUCT MANUAL

- 14 -North America: +1 847.851.1800 | +1 800.527.9948 | www.cetco.com

VOLTEX® & VOLTEX® DSBENTONITE GEOTEXTILE WATERPROOFING FOR CAST-IN-PLACE CONCRETE APPLICATIONS

2.2 SOLDIER PILE & LAGGING RETAINING WALLVerify the following substrate preparation work has been completed. Then install VOLTEX following the property line installation guidelines in Section 2.1 on page 12 and 13.

Preparation: Gaps between the wood lagging must be no wider than 25mm(1”).Ifthegapsbetweenlaggingareinexcessof25mm(1”),thegapsshouldbecompletelyfilledwithcementitiousgrout,wood,ex-trudedpolystyrene(40psimin.)orcompactedsoil(Figure2.7).Ifwaterisflowingthroughthelagging,athinpolyethylenesheetingcanbein-stalled over the area before VOLTEX is installed.

In areas with large gaps (up to 63 mm [2–1/2”]) between lagging,AQUADRAIN sheet drainage composite can be installed over the lagging toprovideauniformsurface tomountVOLTEX (Figure2.8).Securelyfasten AQUADRAIN to the lagging surface with washerhead nails be-foreinstallingVOLTEX.Gapslargerthan63mm(2–1/2”)betweenlag-gingshouldbecompletelyfilledwithgrout,wood,extrudedpolystyrene(40psimin.)orcompactedsoilevenifAQUADRAIN is installed prior to VOLTEX.Donotuseplywoodorothersurfacetreatmentoverlargelag-ginggapsthatleavesthecavityvoid.Details2.10through2.12onpage15 illustrate the installation of VOLTEX over the different wood lagging positions relative to the soldier piling.

Figure 2.8 – AQUADRAIN used to cover gaps in lagging less than 63 mm (2.5”). (Cast-in-placeconcretewall)

Woodlagging

VOLTEX

Grout caps larger than25mm(1”)

WATERSTOP-RX

Woodlagging

VOLTEX

AQUADRAIN

WATERSTOP-RX

Figure2.9–InstallVOLTEXontosoldierpileandwoodlaggingretainingwallpriortocast-in-placeconcretewall

BENTOSEAL troweled over surface of VOLTEX strip at both edges of the soldier pile

VOLTEX strip centered over soldier pile BENTOSEAL

TB-Boot over tie-back plate

VOLTEX corner transition sheet installed horizontally oriented

VOLTEX base wall course installed horizontally oriented

Wood lagging

Tie-back head

Soldier pile

VOLTEX section

100mm (4”)

INSTALL VOLTEX OR VOLTEX DS WITH DARK GRAY (WOVEN) GEOTEXTILE SIDE FACING INSTALLER

Figure 2.7 – VOLTEX installed di-rectly to wood lagging with gaps filled. (Cast-in-place concretewall)

Page 15: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

www.cetco.com

Wood lagging

Steel piling

VOLTEX main course

VOLTEX strip over pile prior to main course

WATERSTOP-RX (75mm(3”)min coverage)

BENTOSEAL

Cast-in-place concrete wall

Woodlagging

Steel piling

Retained earth

VOLTEX main course

BENTOSEAL between sheets of VOLTEX

VOLTEX strip over pile prior to main course

Fill gap with solid material

Cast-in-place concrete wall

Plate & bolts secure lagging

WATERSTOP-RX (75mm(3")min coverage)

Figure2.11– Lagging secured to inside surfaceof front pile flange.Install VOLTEX strip to cover mounting plates and bolts prior to main course(PlanView)

Figure2.10–Laggingsecuredtooutsidesurfaceof frontpileflangeprovidingsmoothsurface(PlanView)

Figure2.12–Lagging secured to insidesurfaceofbackpile flange.Install BENTOSEAL and VOLTEX strip prior to main VOLTEX course and inward BENTOSEALcant.(PlanView)

Steel piling

Woodlagging

VOLTEX main courseBENTOSEAL, apply two cants – one before VOLTEX strip and one after main course

WATERSTOP-RX to exterior of cut rebar hole in steel piling

VOLTEX strip over pile prior to main VOLTEX course

WATERSTOP-RX (75mm(3”)min coverage)

Figure2.13–WALLEXCAVATIONATGRADE–Cementitiousboardpro-tectswaterproofingduringexcavationandremovalofsteelpiletopandwood lagging

VOLTEX Cementitious board

Woodlagging

Steel H-pile, top removed with excavation work

AQUADRAIN sheet drainCast-in-place concrete wall

Page 16: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

PRODUCT MANUAL

- 16 -North America: +1 847.851.1800 | +1 800.527.9948 | www.cetco.com

VOLTEX® & VOLTEX® DSBENTONITE GEOTEXTILE WATERPROOFING FOR CAST-IN-PLACE CONCRETE APPLICATIONS

Figure 2.14 – Sheet pile interlock detail

Figure 2.15 – Install VOLTEX onto metal sheet piling retaining wall with powder-actuated fasteners

2.3 METAL SHEET PILING RETAINING WALLVerify the following substrate preparation work has been completed. Then install VOLTEX following the property line installation guidelines in Section 2.1 on page 12 and 13. Special knurled powder-actuated fas-teners are recommended to secure VOLTEX to the metal sheet piling.

Preparation:Trowela12mm(1/2”)thicklayerofBENTOSEAL along all sheet piling knuckles. Fill voids or cavities at tieback plates with ce-mentitious grout or compacted soils. If excessive water is penetrating the sheet piling knuckles, Bentogrout can be injected to the outside of theknuckletostopwaterflow(Figure2.14).ConsultCETCOforBentogrout applications and installation guidelines.

Alternate Plywood MethodAlternatively,12mm(1/2”)plywoodmaybefastenedtothesheetpilingtocreateaflatsurfaceuponwhichVOLTEXisfastened.Allvoidspacesbetweentheplywoodandsheetpilingmustbefilledwithcompactedearth or concrete. Apply VOLTEX to plywood following “Property Line Construction”GuidelinesinSection2,Page11.

BENTOGROUT injected to exterior sideofsheetpileinterlock(perprojectrequirements)

Retained earth

Sheet piling

VOLTEXBENTOSEALSheet pile interlock

Cast-in-place concrete wall

VOLTEX vertical seams should not occur at interlocking of sheet piling

VOLTEX

WATERSTOP-RX (75mm(3”)mincoverage)

Retained earth

Metal sheet piling

Completelyfillareabehind plywood with compacted soil or concrete

Optional technique: plywood fastened to sheet piling to form flatsurfacetomountVOLTEX

INSTALL VOLTEX OR VOLTEX DS WITH DARK GRAY (WOVEN) GEOTEXTILE SIDE FACING INSTALLER

Page 17: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

www.cetco.com

2.4 EARTH FORMED SHOTCRETE RETAINING WALLVerify the following substrate preparation work has been completed. Then install VOLTEX following the property line installation guidelines in Section 2.1 on page 12 and 13.

Preparation: The surface of the earth formed diaphragm wall must besufficientlyplanartoprovideanadequatelysmoothsurfacetoapplyVOLTEX. VOLTEX can be applied over large, relatively shallow indenta-tions. The surface should not contain voids or sharp protrusions in ex-cessof25mm(1”).FillallvoidswithcementitiousgroutandremoveprotrusionspriortoinstallingVOLTEX(Figure2.18).

Figure 2.17 – Earth formed concrete retention wall with concrete cais-sonsupports.(PlanView)

Figure 2.18 – VOLTEX installation over an earth formed shotcrete retention wall prior to cast-in-place concrete wall

Figure 2.16 – Grout void area and remove protrusions to provide smooth surface for VOLTEX

WATERSTOP-RX 75mm(3")min-coverage)

Grout irregular areas

VOLTEX

Cast-in-place concrete wall

Shotcrete retaining wall (non-structural)

Shotcrete retaining wall (non-structural)

VOLTEX

WATERSTOP-RX

Cast-in-place concrete wall

Retained earth Concrete caisson

Retained earth

Shotcrete retaining wall (non-structural)

VOLTEX

VOLTEX corner transition sheet horizontally oriented

Grouted depressions and irregular surfaces

100mm(4”)

100mm(4”)INSTALL VOLTEX OR VOLTEX DS WITH DARK GRAY (WOVEN) GEOTEXTILE SIDE FACING INSTALLER

Page 18: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

PRODUCT MANUAL

- 18 -North America: +1 847.851.1800 | +1 800.527.9948 | www.cetco.com

VOLTEX® & VOLTEX® DSBENTONITE GEOTEXTILE WATERPROOFING FOR CAST-IN-PLACE CONCRETE APPLICATIONS

Figure2.19–CutRockexcavationwithshotcreteappliedtoprovideasmoothsurfaceforwaterproofinginstallation

Figure2.20–Fillinrecessesbetweencastcaissonswithgrouttopro-videsmoothsurface(PlanView).

2.5 AUGER CAST CAISSON WALLSVerify the following substrate preparation work has been completed. Then install VOLTEX following the property line installation guidelines in Section 2.1 on page 12 and 13.

Preparation: The surface of auger cast caisson and cut rock excava-tionwallsmustbesufficientlyplanartoprovideanadequatelysmoothsurface to apply VOLTEX. VOLTEX can be applied over large, relative-ly shallow indentations where VOLTEX can conform tight against the surface. The surface should not contain voids or sharp protrusions in excessof25mm(1”).Fillalllargerecessesbetweencaissonswithce-mentitiousgroutpriortoinstallingVOLTEX(Figure2.20).Cutrockexca-vations typically require shotcrete or grout work to provide acceptable surfacetoinstallVOLTEX(Figure2.19).

Figure 2.21 – VOLTEX installation over an auger cast concrete retention wall prior to cast-in-place concrete wall

Retained earth side Concrete caisson

VOLTEX Grout recesses

Retained earth

VOLTEX

100mm(4”)

VOLTEX corner transi-tion sheet horizontally oriented

Shotcrete retaining wall (non-structural)

Grouted depressions and irregular surfaces

Cut rock formation from excavation

Shotcrete applied to cut rock surface(non-structural)

VOLTEX TB-6SNVOLTEX

WATERSTOP-RX

BENTOSEAL detailing

DARK GRAY (WOVEN) GEOTEXTILE SIDE FACING INSTALLER

Page 19: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

www.cetco.com

InstallVOLTEXorVOLTEXDSwiththedarkgray(woven)geotextilesideagainst the concrete wall on cast-inplace concrete foundation walls priortobackfilling.VOLTEXmaybeappliedassoonastheformsareremoved. It is not necessary to wait for the concrete to completely cure. Use VOLTEX with concrete cast with conventional forms that produce smooth surface.

3.1 SURFACE PREPARATIONFooting should be swept clean of silt, rocks and debris to provide VOLTEX with direct contact to the concrete in the application area. The wall sur-face must be properly prepared before VOLTEX is installed. Areas of surfacehoneycombingorvoidsshouldbefilledwithcementitiousgroutor BENTOSEAL.Protrusionsofover6mm(1/4”)shouldbeknockedoffsmooth with the concrete surface. Concrete work should include com-pletelyfillingtaper-tieholeswithnon-shrinkcementitiousgroutandapiece of WATERSTOP-RXcenteredinthewall(Figure3.1).ApplyBEN-TOSEALoverexteriorgroutedsurfaceofallformtieholes(Figure3.1).

3.2 INSTALLATIONBefore installing thefirstcourseofVOLTEX,placeHydrobarTubesatthewall/footinginsidecorner(Figure3.2).“Butt”theendsofHydrobarTubes together to form a continuous line.

Beginning at the bottom corner of the wall, install VOLTEX horizontal-lyorientedwith1.5m(5’)ononewallandtheremainderaroundthecornerontheotherwallsurface(Figure3.2).CutthebottomedgeofVOLTEXatthecorneraminimumof150mm(6”)sothatVOLTEXcanbe extended onto the footing. Fasten VOLTEX into position with washer headfastenersmaximum600mm(24”)oncenter.Thencutandinstalla VOLTEX section over the uncovered footing corner area. Apply BEN-TOSEALattheVOLTEXsectiontoVOLTEXoverlaps.(Figure3.2).

Install adjacent VOLTEX rolls of the bottom course horizontally oriented. Eachrollshouldoverlaptheprecedingrollaminimum100mm(4”)andshould extend onto the footing aminimum150mm (6”). At verticalinsidecornersapplyacontinuous19mm(3/4”)filletofBENTOSEAL directlyinthecornerpriortoinstallingVOLTEX(Figure3.3).Staggerallverticaloverlapjointsaminimumof300mm(12”)(Figure3.4).Whenhydrostatic conditions exist, the vertical wall VOLTEX should cover the entirefootingandoverlaptheunderslabwaterproofingaminimum150mm(6”)(Figure3.6).TapeallVOLTEXDSmembraneoverlapseamswithCETCO Seamtape.

SECTION 3 BACKFILLED WALLS

Figure 3.2 – Start VOLTEX at the corner horizontally. Place cut section at corner and apply BENTOSEAL at overlaps

Figure 3.1 – Concrete form tie details

Figure3.3–ApplyfilletofBENTOSEAL to inside corner

Snap-Tie Taper-Tie

Non-shrink groutConcrete Tile BENTOSEAL exterior

face of form tie

Non-shrink grout

VOLTEX

Install VOLTEX around corner

Hydrobar Tube under VOLTEX

VOLTEX

BENTOSEAL

InstallVOLTEXtofitcorner

Install VOLTEX tofitcorner

19mm(3/4”)filletofBENTOSEAL

Inside corner of cast-in-place concrete wall

WATERSTOP-RX

Page 20: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

PRODUCT MANUAL

- 20 -North America: +1 847.851.1800 | +1 800.527.9948 | www.cetco.com

VOLTEX® & VOLTEX® DSBENTONITE GEOTEXTILE WATERPROOFING FOR CAST-IN-PLACE CONCRETE APPLICATIONS

Figure3.4–VOLTEXinstalledoncast-in-placebackfilledwall,overlapedges100mm(4”)andstaggerverticalendlaps

Backfill: The excavated area should be backfilled and compactedpromptlyafterVOLTEXisinstalled.UseplacedbackfillasaplatforminapplyingsucceedingVOLTEXcourses.Thebackfillmustbecompactedtoaminimum85%ModifiedProctordensity.Backfillshouldconsistofcompactible soilsorangularaggerate (19mm (3/4") or less) freeofdebris,sharpobjects,andstonelargerthan19mm(3/4”).Whenback-fillcannotbeplacedimmediatelyprotectmembranefromprecipitationand debris by sealing edges to concrete substrate with CETCO SEAM-TAPE or tooled bead of CETSEAL. This temporary temination can be left in place covered by subsequent membrane overlap. Figure3.5–MinimumVOLTEXoverlapdetail;tapeVOLTEXDSseams

Figure3.6–Stepbystepdetailofoutsidewallbasecornerinstallation(hydrostaticcondition)

Trowel BENTOSEAL over grouted form-tie holes

VOLTEX

Hydrobar Tubes placed under VOLTEX at transition at footing

Stagger end seams a minimum 300mm(12”)

Mechanically fasten VOLTEX maximum 600 mm (24”) on center

Install CETCO Seamtape atVOLTEXDSmembraneoverlaps

100mm(4”)overlap

WATERSTOP-RX(min75mm(3”))coverage)

150mm(6”)

Min. 100mm (4”)

Cast-in-place concrete wall

Washer-headmechanicalfastener

VOLTEXDS

CETCO Seamtape

Step 1. Step 2.

Step 3. Step 4.

VOLTEX turned up from underslab

Trowel BENTOSEAL at corner

CutandfoldfirstVOLTEX section

Cut and fold second VOLTEX section

Place third VOLTEX piece over the previous two sections

INSTALL VOLTEX OR VOLTEX DS WITH DARK GRAY (WOVEN) GEOTEXTILE SIDE AGAINST THE CONCRETE WALL

Term bar and BENTOSEAL

Page 21: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

www.cetco.com

3.3 BACKFILLED WALL PENETRATIONSCutVOLTEXtocloselyfitaroundpenetrations.AfterinstallingVOLTEX,trowelaminimum19mm(3/4”)thickfilletofBENTOSEAL around the penetrationtocompletelyfillanyspacebetweenthepenetrationandthe VOLTEX edge. The BENTOSEAL should extend onto the penetration 38mm(1–1/2”)andcoverVOLTEX’sedge(Figure3.7).Inareaswheremultiple penetrations are close together, it may be impractical to cut VOLTEXtofitaroundbaseofeachpenetration.Therefore,applya19mm (3/4”) thick fillet of BENTOSEAL around each penetration and covertheentiresurfacebetweenthepenetrations(Figure3.8).ExtendBENTOSEAL38mm(1–1/2”)ontothepenetrations.

Figure 3.7 – Single penetration cast-in-place wall detail

Figure3.10–InstallVOLTEXbetweenpenetrationswithaccessibility.Trowel BENTOSEAL around penetrations

Figure3.8–CutVOLTEXtofitaroundpenetrations

Figure3.9–Closemultiplepenetrations.TrowelBENTOSEAL around and between penetrations

VOLTEX

Cast-in-place concrete wall

BENTOSEAL troweled around penetration

Pipe

WATERSTOP-RX (min.75mm(3”)coverage)

VOLTEX Apply BENTOSEAL to cut out area

VOLTEX cut out around multiple penetrations

WATERSTOP-RX

VOLTEX

BENTOSEAL

Pipe

BENTOSEAL

Pipe

VOLTEX

WATERSTOP-RX

WATERSTOP-RX

VOLTEX

BENTOSEAL

Pipe

BENTOSEAL

VOLTEX

BENTOSEAL

Pipe

VOLTEX

WATERSTOP-RX

Page 22: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

PRODUCT MANUAL

- 22 -North America: +1 847.851.1800 | +1 800.527.9948 | www.cetco.com

VOLTEX® & VOLTEX® DSBENTONITE GEOTEXTILE WATERPROOFING FOR CAST-IN-PLACE CONCRETE APPLICATIONS

3.4 GRADE TERMINATIONSTerminateVOLTEXmembrane300mm(12”)belowfinishedgradeel-evationwithwasher-headfastenersmaximum300mm(12”)oncen-ter. Install ENVIROSHEET flashing to primed concrete substratewithbottom edge overlapping top edge of VOLTEX membrane minimum 100mm(4”).Overlapallrollendsaminimum100mm(4”)toformacontinuousflashing.Heightofflashingshallbeperprojectdetailsandspecifications.InstallarigidterminationbaralongtopedgeofENVIRO-SHEET;fastenedmaximum300mm(12”)oncenter.Completegradetermination detail with tooled bead of CETSEAL along the top edge, at allpenetrationsthroughtheflashing,andallexposedoverlapseams.Grade terminations are illustrated in Figures 3.11 and 3.12.

3.5 MASONRY BLOCK WALLSVOLTEX is not recommended forwaterproofingmasonry blockwalls.Consult with CETCO regarding recommended products and installation guidelines for masonry block walls.

4.1 PRECAST CONCRETE CONSTRUCTIONConsult CETCO regarding products and special installation guidelines for precast concrete plank decks, precast earth covered roofs, and pre-cast wall construction.

4.2 CONTAMINATED CONDITIONSUseVOLTEXCR(ContaminantResistant)inconditionswheretheground-water contains high concentrations of chemicals or saline. These condi-tions are typically encountered at industrial sites and coastal regions. If groundwater contains strong acids, alkalies, or has aconductivityof2,500μmhos/cmorgreater (highsaltconcentration),water samples should be submitted to CETCO for compatibility testing.

Forcompatibility testing,provide two (2) litersofsitegroundwater ina clean, unbreakable container. Shipwater sample to:CETCO,2870ForbsAve,HoffmanEstates,IL60192,ATTN:BMGFieldServices.Uponanalysis, CETCO will provide a written report evaluating the water’s compatibilitywithVOLTEXandrecommendanyspecialproductand/orinstallation requirements

Figure3.11–Terminationatfinishedgrade

Figure 3.12 – Termination at grade with brick veneer

SECTION 4 SPECIAL CONDITIONS

IMPORTANT NOTICEFOR SHOTCRETE, PRECAST CONCRETE, EXPANSION JOINTS AND OTHER APPLICATIONS NOT COVERED IN THIS MANUAL, CONTACT CETCO FOR TECHNICAL ASSISTANCE AND INSTALLATION GUIDELINES.Brick veneer

Weephole

CETSEAL

Finished grade

ENVIROSHEET grade flashing

VOLTEX

ENVIROSHEET grade flashing

VOLTEX

100mm(4”)min

Finished grade

Tooled bead of CETSEAL

Terminationbarfastened300mm(12”)maximumoncenter

Tooled bead of CETSEAL

Terminationbarfastened300mm(12”)maximumoncenter

Page 23: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

www.cetco.com

The information and data contained herein is believed to be accurate and reliable.Specificationsandotherinformationcontainedhereinsupersedeallpreviously printed material and are subject to change without notice. Manufacturer’s warranty of installed system is available. Contact seller for terms and sample documents including all limitations. All goods sold by seller are warranted to be free from defects in material and workmanship. The foregoing warranty is in lieu of and excludes all other warranties not ex-pressly set forth herein, whether expressed or implied by operation of law or otherwise including but not limited to any implied warranties of merchant-abilityorfitness. Seller shall not be liable for incidental or consequential losses, damages or expenses, directly or indirectly arising from the sale, handling or use of the goods, or from any other cause relating thereto, and seller’s liability hereun-derinanycaseisexpresslylimitedtothereplacement(intheformoriginally

shipped)ofgoodsnotcomplyingwiththisagreementoratseller’selection,tothe repayment of, or crediting buyer with, an amount equal to the purchase price of such goods, whether such claims are for breach of warranty or neg-ligence. Any claim by buyer with reference to the goods sold hereunder for any cause shall be deemed waived by buyer unless submitted to seller in writing within thirty(30)daysfromthedatebuyerdiscoveredorshouldofdiscovered,anyclaimed breach. Materials should be inspected and tested by purchaser prior to their use if productqualityissubjecttoverificationaftershipment.Performanceguaran-tees are normally supplied by the applicator.

Note:VOLTEXwaterproofingsystemisnotanexpansionjointmaterial.

LIMITED WARRANTY

PRODUCT TABLEPRODUCT DESCRIPTION

VOLTEX Bentonitegeotextilewaterproofingmembranewithstandardsodiumbentonite

VOLTEX CR Bentonitegeotextilewaterproofingmembranewithcontaminantresistantsodiumbentonite

VOLTEXDS Bentonitegeotextilewaterproofingmembranewithstandardsodiumbentoniteandapolyethylenelinercomponent

VOLTEXDSCR Bentonitegeotextilewaterproofingmembranewithcontaminantresistantsodiumbentoniteandapolyethylenelinercomponent

IMPORTANT NOTICEContact CETCO for verification of specification and instal-lation requirements to comply for eligibility of HydroShield Warranty.

Page 24: VOLTEX & VOLTEX DS...ing system. Concrete work should use conventional cast-in-place forms that produce a smooth surface. Do not use stay-in-placecon-crete forming; use removeable

www.cetco.com

©2015CETCO.IMPORTANT:Theinformationcontainedhereinsupersedesallpreviousprintedversions,andisbelieved to be accurate and reliable. For the most up-to-date information, please visit www.CETCO.com. CETCO accepts no responsibility for the results obtained through application of this product. CETCO reserves the right to update information without notice.

FORM:PM_VOLTEX_AM_EN_201509_V7

www.cetco.com | [email protected]

UPDATED:SEPTEMBER2015