Monitoring, analysing and using Big Data to maintain grid stability and evolve towards a Smarter Grid Aykut Uysal Business Analyst 24 October 2013 Grid navigator LV Gaia Network design MV/LV Load Management Voltage Fluctuation and Preparing for the Future Grid MV Vision Network analysis Grid navigator Scada/DMS Network analysis (dynamic)

Upload: others

Post on 28-Feb-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Voltage Fluctuation and Preparing for the Future GridOct 25, 2013  · ERP (SAP) SCADA/DMS (PSI - ABB) Network analysis tools for MV/LV Q Service Load management (Enexis) MV Vision

Monitoring, analysing and using Big Data to maintain grid stability and evolve towards a Smarter Grid

Aykut Uysal Business Analyst

24 October 2013

Grid navigator LV Gaia Network design

MV/LV Load Management

Voltage Fluctuation and

Preparing for the Future Grid

MV Vision Network analysis

Grid navigator

Scada/DMS

Network analysis (dynamic)

Page 2: Voltage Fluctuation and Preparing for the Future GridOct 25, 2013  · ERP (SAP) SCADA/DMS (PSI - ABB) Network analysis tools for MV/LV Q Service Load management (Enexis) MV Vision

25 oktober 2013

Electricity

Enexis

● Meter

reading

● Construction

of networks ● Management

of networks

● Maintenance and trouble-

shooting of networks

● Development

of networks

Dutch DSO

o Enexis manages the energy netw orks in the Northern, Eastern and Southern parts of the

Netherlands.

o We provide electricity to 2,6 million and gas to 2 million customers.

o We maintain and renew the network (power cables, gas pipelines and substations) and care for

high standards of network reliability and safety

Electricity

• 2,6 miljoen Customers

• 140.000 km MV-/LV-Cables

• 51.000 transformer stations

• SAIDI* 22 min. per year

* System Average Interruption Duration Index

Gas

• 2,0 miljoen Customers

• 44.000 km HD en LD gas mains

• 24.000 stations

• SAIDI* < 30 sec.

Page 3: Voltage Fluctuation and Preparing for the Future GridOct 25, 2013  · ERP (SAP) SCADA/DMS (PSI - ABB) Network analysis tools for MV/LV Q Service Load management (Enexis) MV Vision

25 oktober 2013

Agenda

Corporate information systems

GIS (GE Smallworld)

ERP (SAP)

SCADA/DMS (PSI - ABB)

Network analysis tools for MV/LV

Q Service Load management (Enexis)

MV Vision Network Analysis (Phase to Phase)

LV Gaia Network Design (Phase to Phase)

Gridnavigator (Phase to Phase)

System connections and data migration

IST and SOLL

Demo

Conclusion

Page 4: Voltage Fluctuation and Preparing for the Future GridOct 25, 2013  · ERP (SAP) SCADA/DMS (PSI - ABB) Network analysis tools for MV/LV Q Service Load management (Enexis) MV Vision

25 oktober 2013

Convert data into valuable information

ATTITUDE

(Technological) SKILLS

EXPERIENCE

BUSINESS RULES

Page 5: Voltage Fluctuation and Preparing for the Future GridOct 25, 2013  · ERP (SAP) SCADA/DMS (PSI - ABB) Network analysis tools for MV/LV Q Service Load management (Enexis) MV Vision

5 Enexis

Customer Management & Operational Systems

Asset Management & Operations

Support

Enexis Customers Partners

WOM – IS Mobile

ECM SAP HR

Portals – Sharepoint / (Presentations)

Data en Application Integration / (Data Consistentie en Web-services)

Business Intelligence (SAP BW, DDWH, EDWH, ..) (Reports)

MRGV

EI-Server

ISU - KNEXIS

BAR-EG

GIS – GEN/Viewers

Plato

Nestor

Pisa

Civiel

NSM / ASR

Commerc. Activities

ISU - AIS

Business Process Management / (Workflow support)

ERP - ODYSSEUS

CRM STAP

Basic systems Specific systems

Unitmanager

Business en System architecture ENEXIS

DMS - PSI

Page 7: Voltage Fluctuation and Preparing for the Future GridOct 25, 2013  · ERP (SAP) SCADA/DMS (PSI - ABB) Network analysis tools for MV/LV Q Service Load management (Enexis) MV Vision

GIS Geographical information System

(MV)

7

MV Schematic Layout

• Topological/geographic MV/LV grid data (equipment parameters)

• Underground Assets (cables, connections)

• Overground Assets ((circuit breaker, MV installation (Sync EQ from SAP R/3 (ERP))

• Customer connectivity

MV Geografical layout

GEN/GIS

Page 8: Voltage Fluctuation and Preparing for the Future GridOct 25, 2013  · ERP (SAP) SCADA/DMS (PSI - ABB) Network analysis tools for MV/LV Q Service Load management (Enexis) MV Vision

8

LV Installation Layout

LV Geografical layout

GEN/GIS Geographical information System

(LV) GEN/GIS

Page 9: Voltage Fluctuation and Preparing for the Future GridOct 25, 2013  · ERP (SAP) SCADA/DMS (PSI - ABB) Network analysis tools for MV/LV Q Service Load management (Enexis) MV Vision

ERP SAP R/3

• Assets overground

• MV/LV transformerload data

• MS cable load in:

• HV/MV stations

• Strategic MV substations

9

SAP R/3 (ERP)

(New: Metering with smart meters)

Page 10: Voltage Fluctuation and Preparing for the Future GridOct 25, 2013  · ERP (SAP) SCADA/DMS (PSI - ABB) Network analysis tools for MV/LV Q Service Load management (Enexis) MV Vision

Customer Data SAP ISU (Business/Domestic)

10

Customer data

EAN code

Name

Adress

Street

Postal

Connection data

Load data

SAP ISU - KNEXIS

SAP ISU - AIS

Page 11: Voltage Fluctuation and Preparing for the Future GridOct 25, 2013  · ERP (SAP) SCADA/DMS (PSI - ABB) Network analysis tools for MV/LV Q Service Load management (Enexis) MV Vision

SCADA/DMS (PSI)

11

Substation Automation

G

Metering

system

LV

Dis

tr./

Cust

.

±2.6

mln

connect

ions

HV

- /M

V

±130 s

tatio

ns

MV

Dis

trib

utio

n

±50.0

00 M

V/L

V

RM

U’s

G

Metering

system

LV

Dis

tr./

Cust

.

±2.6

mln

connect

ions

HV

/MV

±130 s

ubst

atio

ns

MV

Tra

nsp

ort

±1.7

00 s

ubst

atio

ns

MV

Dis

trib

utio

n

±50.0

00 s

ubst

atio

ns

G

Metering

system

LV

Dis

tr./

Cust

.

±2.6

mln

connect

ions

HV

- /M

V

±130 s

tatio

ns

MV

Dis

trib

utio

n

±50.0

00 M

V/L

V

RM

U’s

G

Metering

system

LV

Dis

tr./

Cust

.

±2.6

mln

connect

ions

HV

/MV

±130 s

ubst

atio

ns

MV

Tra

nsp

ort

±1.7

00 s

ubst

atio

ns

MV

Dis

trib

utio

n

±50.0

00 s

ubst

atio

ns

G

Metering

system

LV

Dis

tr./

Cust

.

±2.6

mln

connect

ions

HV

- /M

V

±130 s

tatio

ns

MV

Dis

trib

utio

n

±50.0

00 M

V/L

V

RM

U’s

G

Metering

system

LV

Dis

tr./

Cust

.

±2.6

mln

connect

ions

HV

/MV

±130 s

ubst

atio

ns

MV

Tra

nsp

ort

±1.7

00 s

ubst

atio

ns

MV

Dis

trib

utio

n

±50.0

00 s

ubst

atio

ns

Actual Grid status (dynamic)

G

Metering

system

LV

Dis

tr./

Cu

st.

± 2

.6 m

ln

co

nn

ectio

ns

HV

- /M

V

± 1

30

sta

tio

ns

MV

Dis

trib

utio

n

±

50

.00

0 M

V/L

V

RM

U ’ s

G

Metering

system

LV

Dis

tr./

Cu

st.

± 2

.6 m

ln

co

nn

ectio

ns

HV

/MV

± 1

30

su

bsta

tio

ns

MV

Tra

nsport

± 1

.70

0 s

ub

sta

tio

ns

MV

Dis

trib

utio

n

± 5

0.0

00

su

bsta

tio

ns

G

Metering

system

LV

Dis

tr./

Cu

st.

± 2

.6 m

ln

co

nn

ectio

ns

HV

- /M

V

± 1

30

sta

tio

ns

MV

Dis

trib

utio

n

±

50

.00

0 M

V/L

V

RM

U ’ s

G

Metering

system

LV

Netw

ork

± 2

.6 m

ln

co

nn

ectio

ns

HV

/MV

± 1

30

su

bsta

tio

ns

MV

Tra

nsport

± 1

.70

0 s

ub

sta

tio

ns

MV

Dis

trib

utio

n

± 5

0.0

00

su

bsta

tio

ns

Enhanced insight in MV network Remote monitoring MV network

Reduction SAIDI*

Remote monitoring MV network down to MV/LV

* System Average Interruption Duration Index

More efficient management MV network Enhanced automation Control Centre

Scada/DMS

Network analysis (dynamic)

Page 12: Voltage Fluctuation and Preparing for the Future GridOct 25, 2013  · ERP (SAP) SCADA/DMS (PSI - ABB) Network analysis tools for MV/LV Q Service Load management (Enexis) MV Vision

(MV) Network analysis Vision

Loadflow/Network analysis Network load and voltage management

Outage analysis

Voltage dips

Contingency analysis

Protection

Georg Simon Ohm

symmetrical and asymmetrical short-circuit All network currents per phase

Subtransient short-circuit current and short-circuit power

Fault analysis Symmetrical and asymmetrical fault analysis

Fault impedances

Page 13: Voltage Fluctuation and Preparing for the Future GridOct 25, 2013  · ERP (SAP) SCADA/DMS (PSI - ABB) Network analysis tools for MV/LV Q Service Load management (Enexis) MV Vision

(LV) Network design Gaia

13

Gustav Robert Kirchhoff

Voltage quality Network impedance,

Voltage drop and

Voltage dip calculations

Network Load Optimum network design module

Unbalanced load flow Full three phase plus neutral

and screen asymmetrical load flow module

Safety

Evaluation of contact safety module

Short circuit:

Three phase and

Phase to ground short circuit analysis

Page 14: Voltage Fluctuation and Preparing for the Future GridOct 25, 2013  · ERP (SAP) SCADA/DMS (PSI - ABB) Network analysis tools for MV/LV Q Service Load management (Enexis) MV Vision

Gridnavigator design and operate the smart grid

Need to combine the schematic and geografical information

Question: a GIS that can present load

flow?

or a power system analysis program which can present geographically?

Page 16: Voltage Fluctuation and Preparing for the Future GridOct 25, 2013  · ERP (SAP) SCADA/DMS (PSI - ABB) Network analysis tools for MV/LV Q Service Load management (Enexis) MV Vision

25 oktober 2013

16

MV Load Management

Vision Network analysis

Grid Navigator

Data faults solution

GIS information

• GIS Data • SAP R/3 PM Data • SAP AIS Data

- Data Validation - Inconsistentie

Long Term planning not Real time

AIS

SYNC

System Connection for MV Analysis (IST)

Analytics and visualisation GEN/GIS

SAP R/3 (ERP)

SAP ISU - AIS

Equipments/Loads

Business Customer Load/Data > 3x80 A

SYNC

Business rules and parameters

Page 17: Voltage Fluctuation and Preparing for the Future GridOct 25, 2013  · ERP (SAP) SCADA/DMS (PSI - ABB) Network analysis tools for MV/LV Q Service Load management (Enexis) MV Vision

25 oktober 2013

17

System Connection for LV Analysis (IST)

Gaia LV Network design

Grid Navigator

Long Term not Real time AIS

GEN/GIS

SAP R/3 (ERP)

SAP ISU - KNEXIS

Domestic Customer Load/Data ≤ 3x80 A

Equipments

Geospatial data

SYNC

Data faults solution

Page 18: Voltage Fluctuation and Preparing for the Future GridOct 25, 2013  · ERP (SAP) SCADA/DMS (PSI - ABB) Network analysis tools for MV/LV Q Service Load management (Enexis) MV Vision

Gaia LV Network design

Grid Navigator

18

Dynamic Data Ware House

Data concentrator

MV/LV Substations

• Fault Data • Current/Voltage • DA • Smart meter data

MV Load Management

SAP R/3 (ERP)

Data faults solution

• GEO spatial Data • SAP R/3 ERP Data • SAP ISU – KNEXIS • SAP ISU - AIS

Business rules and parameters

GEN/GIS

SAP ISU - KNEXIS

SAP ISU - AIS

Vision Network analysis

Grid Navigator

Data redundancy consistency

Scada/DMS

Network analysis (dynamic)

System Connection for MV/LV Analysis (SOLL)

Page 19: Voltage Fluctuation and Preparing for the Future GridOct 25, 2013  · ERP (SAP) SCADA/DMS (PSI - ABB) Network analysis tools for MV/LV Q Service Load management (Enexis) MV Vision

25 oktober 2013

DEMO

Page 20: Voltage Fluctuation and Preparing for the Future GridOct 25, 2013  · ERP (SAP) SCADA/DMS (PSI - ABB) Network analysis tools for MV/LV Q Service Load management (Enexis) MV Vision

25 oktober 2013

Conclusion

• Dataownership strategy and quality is a must

• One logical network model and single source of data truth

• Data becomes more and more realtime and will only increase in the future

next steps • Data validation based on quality and completeness

• Make real time load data available

• Establish the Dynamic Data Ware House Accessibilty of the data to gain the benefits of “BIG” data analysis to evolve with dedicated tools

[email protected]