Page 1: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

1EMC CONFIDENTIAL—INTERNAL USE ONLY

VMware vCenter Site Recovery Manager 5.xwith EMC VNX Arrays & MirrorView

By Dave O’Sullivan

[email protected]

Page 2: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

2EMC CONFIDENTIAL—INTERNAL USE ONLY

Intended Audience:

- VNX Block- CLARIION Block

- This training is designed to give an overview of SRM and explain how the relevant software plugins and hardware all interact with each other.

- This will cover :

- Pre-requisites- Design- Test Failover / Failover / Recovery [DEMO]- Required Logs- Troubleshooting

Page 3: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

3EMC CONFIDENTIAL—INTERNAL USE ONLY

Assumptions:

- You are familiar [not expert] with:

- VM’s !- vCenter- MirrorView A and S- VNX / CLARIION Arrays- SRA (s) ???

- Before the customer does any work with SRM:- MirrorView is working (check zoning)- All the appropriate software is installed. [including enablers]

Page 4: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

4EMC CONFIDENTIAL—INTERNAL USE ONLY

What is SRM?

- ensures the simplest and most reliable disaster protection for all virtualized applications.

- Site Recovery plans can be tested non-disruptively as frequently as required to ensure that they meet business objectives.

- At the time of a site failover or migration, Site Recovery Manager automates both failover and failback processes, ensuring fast and highly predictable recovery point objectives (RPOs) and recovery time objectives (RTOs).

Page 5: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

5EMC CONFIDENTIAL—INTERNAL USE ONLY

Pre-requisites

- SRM is heavily reliant on DNS, so it would be assumed DNS is fully setup and all hosts can be resolved in both directions.

- IP Connectivity between all SP’s / VC / ESX on both sites.- SRM is also reliant on Databases, in this setup there are 4 in total.

- 1 DB for VC- 1 DB for SRM

- This applies for both sites.- This doc covers the DB setup in full details :

Virtual How to Install and ConfigureSQL Express 2005For use with Site Recovery Manager V4Rob Nourse, Sr. Consultant VMware Consulting Services

http://communities.vmware.com/servlet/JiveServlet/download/11547-1-32136/Install%20%26%20Configure%20SQL%20Express%20for%20use%20with%20SRM4%20v1.3.pdf

Page 6: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

6EMC CONFIDENTIAL—INTERNAL USE ONLY

Design:

- ….

Page 7: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

7EMC CONFIDENTIAL—INTERNAL USE ONLY

Design considerations : IP / DNS

Page 8: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

8EMC CONFIDENTIAL—INTERNAL USE ONLY

Design considerations : Software / Plugins

Page 9: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

9EMC CONFIDENTIAL—INTERNAL USE ONLY

Design considerations: MirrorView- In order for SRM failover to work, the “protected” VM’s must be

located within a LUN that is replicated form production site to DR site.

- This is handled my MirrorView A/S (we are using A in this setup)- Below is the LUN info for my setup:

Page 10: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

10EMC CONFIDENTIAL—INTERNAL USE ONLY

Design considerations: MirrorView Zoning

- For MirrorView to work, we need to ensure that the appropriate ports are zoned together.

- So in the setup, the FC ports used for MirrorView are zoned to the opposite Array.

Page 11: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

11EMC CONFIDENTIAL—INTERNAL USE ONLY

Design considerations: MirrorView

Page 12: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

12EMC CONFIDENTIAL—INTERNAL USE ONLY

Design considerations: MirrorView- LUN is created first on Prod (Athena) side- Then used MirrorView options “create secondary mirror” and follow

thru wizard.- I used the Mirror Wizard to complete this task

Page 13: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

13EMC CONFIDENTIAL—INTERNAL USE ONLY

Design considerations: MirrorView- When its working, it should look like this:

Page 14: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

14EMC CONFIDENTIAL—INTERNAL USE ONLY

Design considerations: Reserved Lun Pool

- You must add LUNs with adequate capacity to the Reserved LUN Pool before proceed.

- This will be used when the SRA calls a snapshot for the SRM failover test (only!)

Page 15: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

15EMC CONFIDENTIAL—INTERNAL USE ONLY

Design considerations: DEMO

Page 16: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

16EMC CONFIDENTIAL—INTERNAL USE ONLY

Design considerations:- That’s pretty much it on the VNXZ side- Once MirrorView is up & running, you should be good to go with the

SRM windows / VMWare side of the setup.

- Next

-What is the SRA?

Page 17: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

17EMC CONFIDENTIAL—INTERNAL USE ONLY

SRA [Storage Replication Adapters]- What is the SRA?- The SRA is a windows .exe installed on the same windows box as

SRM as part of the SRM setup- The vCenter “talks” to the SRA -> the SRA sends navi commands to

the Array.- This is why naviseccli is required to be installed don the same box as

SRM (check path!)- Each Array vendor has their own SRA adapters.- The SRA’s are EMC code, so we support them!

SRAs for SRM 5.xFor the full list of storage replication adapters supported by SRM 5.x, see

http://www.vmware.com/resources/compatibility/search.php?deviceCategory=sra.

Page 18: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

18EMC CONFIDENTIAL—INTERNAL USE ONLY

SRA [Storage Replication Adapters]- These are the most current supported EMC SRA’s

Page 19: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

19EMC CONFIDENTIAL—INTERNAL USE ONLY

SRA [Storage Replication Adapters]- So on both sites, the following should be installed:

- Note that there is 2 SRA’s- VNX SRA for vCenter- MirrorView enabler for VNX SRA

- As we are only doing block replication, we only need the MirrorView enabler.

- NFS replication is also possible using the EMC_VNX_Replicator_Enabler_for_VNX_SRA_v5.0.xx

Page 20: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

20EMC CONFIDENTIAL—INTERNAL USE ONLY

SRA [Storage Replication Adapters] DEMO

Page 21: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

21EMC CONFIDENTIAL—INTERNAL USE ONLY

Test Failover – sequence of eventsWe will look happens on both sites concerning:

• SRM• VNX• ESX

Page 22: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

22EMC CONFIDENTIAL—INTERNAL USE ONLY

Test Failover – sequence of events [PROD]

Page 23: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

23EMC CONFIDENTIAL—INTERNAL USE ONLY

Test Failover – sequence of events [PROD]- Ensure to check the output form:

Recovery Plan History ReportVMware Site Recovery Manager 5.0

Page 24: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

24EMC CONFIDENTIAL—INTERNAL USE ONLY

Test Failover – sequence of events [PROD]- The is a cosmetic issue which *should* be fixed in later versions of

SRM

Warning: Failed to update embedded paths in virtual machine file '/vmfs/volumes/507432e1-3a92a2a4-027e-b8ac6f866cc6/2008-1/2008-1_1.vmdk'. A general system error occurred: No such deviceFailed to update embedded paths in virtual machine file '/vmfs/volumes/507432e1-3a92a2a4-027e-b8ac6f866cc6/2008-2/2008-2_1.vmdk'. A general system error occurred: No such device

Page 25: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

25EMC CONFIDENTIAL—INTERNAL USE ONLY

Test Failover – sequence of events [PROD ESX]- Some fairly serious errors in the vmkernel on prod. Esx, these can be

ignored.

)WARNING: VMW_SATP_LIB_CX: satp_lib_cx_otherSPIsHung:338:Path "vmhba2:C0:T1:L3" Peer SP is hung.)WARNING: VMW_SATP_LIB_CX: satp_lib_cx_otherSPIsHung:338:Path "vmhba3:C0:T0:L3" Peer SP is hung.)ALERT: NMP: vmk_NmpVerifyPathUID:1166:The physical media represented by device naa.600601609da02e0012ce6a8f930de211 (path vmhba3:C0:T1:L9) has changed. If this is a data LUN, this is a critical error. Detecte[0$)ALERT: NMP: vmk_NmpVerifyPathUID:1166:The physical media represented by device naa.600601609da02e0012ce6a8f930de211 (path vmhba2:C0:T0:L9) has changed. If this is a data LUN, this is a critical error. Detecte[0$)NMP: nmp_DeviceUpdatePathStates:547: Activated path "vmhba2:C0:T1:L9" for NMP device "naa.600601609da02e0012ce6a8f930de211".

- Watch out for messages like this, customers could open cases based on these errors alone…

Page 26: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

26EMC CONFIDENTIAL—INTERNAL USE ONLY

Test Failover – sequence of events [DR]

Page 27: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

27EMC CONFIDENTIAL—INTERNAL USE ONLY

Test Failover – sequence of events[DR ESX]

LVM: 8445:00:00Device naa.6006016054502e005e32bf721a12e211:1 detected to be a snapshot:

LVM: 8452:00:00queried disk ID: <type 2, len 22, lun 11, devType 0, scsi 0, h(id) 14674641011867526612>

LVM: 8459:00:00on-disk disk ID: <type 2, len 22, lun 1, devType 0, scsi 0, h(id) 15441737393007327004>

LVM: 8445:00:00Device naa.6006016054502e005e32bf721a12e211:1 detected to be a snapshot:

LVM: 8452:00:00queried disk ID: <type 2, len 22, lun 11, devType 0, scsi 0, h(id) 14674641011867526612>

LVM: 8459:00:00on-disk disk ID: <type 2, len 22, lun 1, devType 0, scsi 0, h(id) 15441737393007327004>

LVM: 8445:00:00Device naa.6006016054502e005e32bf721a12e211:1 detected to be a snapshot:

LVM: 8452:00:00queried disk ID: <type 2, len 22, lun 11, devType 0, scsi 0, h(id) 14674641011867526612>

LVM: 8459:00:00on-disk disk ID: <type 2, len 22, lun 1, devType 0, scsi 0, h(id) 15441737393007327004>

LVM: 8445:00:00Device naa.6006016054502e005e32bf721a12e211:1 detected to be a snapshot:

LVM: 8452:00:00queried disk ID: <type 2, len 22, lun 11, devType 0, scsi 0, h(id) 14674641011867526612>

LVM: 8459:00:00on-disk disk ID: <type 2, len 22, lun 1, devType 0, scsi 0, h(id) 15441737393007327004>

LVM: 8825:00:00Device naa.6006016054502e005e32bf721a12e211:1 unsnapped

LVM: 5510:00:00Snapshot LV <snap-37ce81f0-503f25d9-c56a845d-4ee3-0026b9736706> successfully resignatured

LVM: 13188 : One or more LVM devices have been discovered.

Page 28: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

28EMC CONFIDENTIAL—INTERNAL USE ONLY

Test Failover – sequence of events[DR VNX]• A 10/09/12 14:20:23 SnapCopy 7100000a Snapshot Logical Unit device CopyDisk0000 has been created.

• B 10/09/12 14:20:23 SnapCopy 7100000a Snapshot Logical Unit device CopyDisk0000 has been created.• A 10/09/12 14:20:24 4600 'Create a SnapShot LU' called by 'admin' (10.64.29.93) on 'Navi_SnapCopyFeature' with

result: Success (Successfully created SnapShot LU.)• A 10/09/12 14:20:27 4600 '' called by 'admin' (10.64.29.93) on 'Navi_SnapCopyFeature' with result: Success (Started

SnapView session successfully. Session name - async-25_SRM-TEST-FAILOVER_session)• A 10/09/12 14:20:27 SnapCopy 71000003 SnapView persistent session async-25_SRM-TEST-FAILOVER_session has been

started on LUN 25.• B 10/09/12 14:20:27 SnapCopy 71000003 SnapView persistent session async-25_SRM-TEST-FAILOVER_session has been started

on LUN 25.• A 10/09/12 14:20:30 4600 'Activate' called by 'admin' (10.64.29.93) on 'SnapShot WWN:

60:06:01:60:54:50:2E:00:92:7D:58:76:1C:12:E2:11' with result: Success (Successfully activated snapshot LU: 60:06:01:60:54:50:2E:00:92:7D:58:76:1C:12:E2:11 (async-25_SRM-TEST-FAILOVER_session))

• A 10/09/12 14:20:35 4600 'ExecuteClientRequest' called by ' Navi User admin' (10.64.29.93) on 'CLIFeature' (Result: Success). snapview -storagegroup -addsnapshot -gname SG_dellpr710-g.emcvmw.ctc -hlu 9 -snapshotname async-25_SRM-TEST-FAILOVER -compatibilitymode called by 'admin'

• A 10/09/12 14:20:39 RemoteMirror 71050115 MirrorView quiesce LU request.• A 10/09/12 14:20:39 RemoteMirror 71050139 RM_ADMIN_INFO_WILL_REBIND the object.• A 10/09/12 14:20:39 RemoteMirror 71050111 MirrorView rebind request for LUN 60060160b9502e00:a4cc7fc81507e211.• A 10/09/12 14:20:39 RemoteMirror 71050115 MirrorView quiesce LU request.• A 10/09/12 14:20:39 SnapCopy 71000006 SnapView has been bound to device 00000017.• B 10/09/12 14:20:39 RemoteMirror 71050136 Quiesce request from peer SP.• B 10/09/12 14:20:39 RemoteMirror 71050136 Quiesce request from peer SP.• B 10/09/12 14:20:39 RemoteMirror 71050120 Rebind request from peer SP for LUN 60060160b9502e00:a4cc7fc81507e211.• B 10/09/12 14:20:39 SnapCopy 71000006 SnapView has been bound to device Disk0001.• B 10/09/12 14:20:39 RemoteMirror 71050120 Rebind request from peer SP for LUN 60060160b9502e00:a4cc7fc81507e211.• A 10/09/12 14:20:40 4600 'Create a SnapShot LU' called by 'admin' (10.64.29.93) on 'Navi_SnapCopyFeature' with

result: Success (Successfully created SnapShot LU.)• A 10/09/12 14:20:40 SnapCopy 7100000a Snapshot Logical Unit device CopyDisk0001 has been created.• B 10/09/12 14:20:40 SnapCopy 7100000a Snapshot Logical Unit device CopyDisk0001 has been created.• A 10/09/12 14:20:43 4600 '' called by 'admin' (10.64.29.93) on 'Navi_SnapCopyFeature' with result: Success (Started

SnapView session successfully. Session name - sync-24_SRM-TEST-FAILOVER_session)• A 10/09/12 14:20:43 Bus1 Enc0 DskE 60a A logical unit has been enabled [ALU 2] 0 ffff0000 2100e• A 10/09/12 14:20:43 SnapCopy 71000003 SnapView persistent session sync-24_SRM-TEST-FAILOVER_session has been started

on LUN 24.

Page 29: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

29EMC CONFIDENTIAL—INTERNAL USE ONLY

Test Failover – sequence of events[DR VNX]• B 10/09/12 14:20:43 Bus1 Enc0 DskE 606 Unit Shutdown for Trespass [ALU 2] 0 ffff0000 2100e

• B 10/09/12 14:20:43 SnapCopy 71000003 SnapView persistent session sync-24_SRM-TEST-FAILOVER_session has been started on LUN 24.

• A 10/09/12 14:20:46 4600 'Activate' called by 'admin' (10.64.29.93) on 'SnapShot WWN: 60:06:01:60:54:50:2E:00:32:0B:08:80:1C:12:E2:11' with result: Success (Successfully activated snapshot LU: 60:06:01:60:54:50:2E:00:32:0B:08:80:1C:12:E2:11 (sync-24_SRM-TEST-FAILOVER_session))

• A 10/09/12 14:20:51 4600 'ExecuteClientRequest' called by ' Navi User admin' (10.64.29.93) on 'CLIFeature' (Result: Success). snapview -storagegroup -addsnapshot -gname SG_dellpr710-g.emcvmw.ctc -hlu 10 -snapshotname sync-24_SRM-TEST-FAILOVER -compatibilitymode called by 'admin'

• A 10/09/12 14:20:55 RemoteMirror 71050115 MirrorView quiesce LU request.• A 10/09/12 14:20:55 RemoteMirror 71050111 MirrorView rebind request for LUN 60060160b9502e00:fe606cb30d03e211.• A 10/09/12 14:20:55 RemoteMirror 71050115 MirrorView quiesce LU request.• A 10/09/12 14:20:55 SnapCopy 71000006 SnapView has been bound to device 0000000f.• A 10/09/12 14:20:55 RemoteMirror 71050139 RM_ADMIN_INFO_WILL_REBIND the object.• B 10/09/12 14:20:55 RemoteMirror 71050136 Quiesce request from peer SP.• B 10/09/12 14:20:55 RemoteMirror 71050120 Rebind request from peer SP for LUN 60060160b9502e00:fe606cb30d03e211.• B 10/09/12 14:20:55 RemoteMirror 71050136 Quiesce request from peer SP.• B 10/09/12 14:20:55 SnapCopy 71000006 SnapView has been bound to device Disk0002.• B 10/09/12 14:20:55 RemoteMirror 71050120 Rebind request from peer SP for LUN 60060160b9502e00:fe606cb30d03e211.• A 10/09/12 14:20:56 4600 'Create a SnapShot LU' called by 'admin' (10.64.29.93) on 'Navi_SnapCopyFeature' with

result: Success (Successfully created SnapShot LU.)• A 10/09/12 14:20:56 SnapCopy 7100000a Snapshot Logical Unit device CopyDisk0002 has been created.• B 10/09/12 14:20:56 SnapCopy 7100000a Snapshot Logical Unit device CopyDisk0002 has been created.• A 10/09/12 14:20:59 4600 '' called by 'admin' (10.64.29.93) on 'Navi_SnapCopyFeature' with result: Success (Started

SnapView session successfully. Session name - sync-0_SRM-TEST-FAILOVER_session)• A 10/09/12 14:20:59 SnapCopy 71000003 SnapView persistent session sync-0_SRM-TEST-FAILOVER_session has been started on

LUN 0.• A 10/09/12 14:20:59 Bus1 Enc0 DskE 60a A logical unit has been enabled [ALU 3] 0 ffff0001 3100e• B 10/09/12 14:20:59 Bus1 Enc0 DskE 606 Unit Shutdown for Trespass [ALU 3] 0 ffff0001 3100e• B 10/09/12 14:20:59 SnapCopy 71000003 SnapView persistent session sync-0_SRM-TEST-FAILOVER_session has been started on

LUN 0.• A 10/09/12 14:21:02 4600 'Activate' called by 'admin' (10.64.29.93) on 'SnapShot WWN:

60:06:01:60:54:50:2E:00:54:39:77:89:1C:12:E2:11' with result: Success (Successfully activated snapshot LU: 60:06:01:60:54:50:2E:00:54:39:77:89:1C:12:E2:11 (sync-0_SRM-TEST-FAILOVER_session))

• A 10/09/12 14:21:06 4600 'ExecuteClientRequest' called by ' Navi User admin' (10.64.29.93) on 'CLIFeature' (Result: Success). snapview -storagegroup -addsnapshot -gname SG_dellpr710-g.emcvmw.ctc -hlu 11 -snapshotname sync-0_SRM-TEST-FAILOVER -compatibilitymode called by 'admin' f

Page 30: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

30EMC CONFIDENTIAL—INTERNAL USE ONLY

Test Failover – sequence of events [DEMO]

Page 31: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

31EMC CONFIDENTIAL—INTERNAL USE ONLY

Cleanup – sequence of events [PROD]Recovery Step Result Step Started Step Completed Execution Time

1. Power Off Test VMs at Recovery Site

Success 2012-10-09 14:46:24 (UTC 0) 2012-10-09 14:46:30 (UTC 0)

1.1. 2008-1 Success 2012-10-09 14:46:24 (UTC 0) 2012-10-09 14:46:30 (UTC 0)

1.1.1. Power Off Success 2012-10-09 14:46:24 (UTC 0) 2012-10-09 14:46:25 (UTC 0)

1.1.2. Reset Storage Success 2012-10-09 14:46:30 (UTC 0) 2012-10-09 14:46:30 (UTC 0)

1.2. 2008-2 Success 2012-10-09 14:46:24 (UTC 0) 2012-10-09 14:46:30 (UTC 0)

1.2.1. Power Off Success 2012-10-09 14:46:24 (UTC 0) 2012-10-09 14:46:27 (UTC 0)

1.2.2. Reset Storage Success 2012-10-09 14:46:30 (UTC 0) 2012-10-09 14:46:30 (UTC 0)

2. Resume Non-critical VMs at Recovery Site

Inactive

3. Discard Test Data and Reset Storage

Success 2012-10-09 14:46:30 (UTC 0) 2012-10-09 14:47:25 (UTC 0)

3.1. Protection Group test7 Success 2012-10-09 14:46:30 (UTC 0) 2012-10-09 14:47:25 (UTC 0)

Device "Mirror of dellpr710-c.w2k8.emcvm...": Success

Device "Mirror of dellpr710-c.w2k8.emcvmw.ctc RDM-23": Success

Device "Mirror of dellpr710-c.w2k8.emcvmw.ctc SRM_VMs": Success

Page 32: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

32EMC CONFIDENTIAL—INTERNAL USE ONLY

Cleanup– sequence of events [PROD ESX]- Some fairly serious errors in the vmkernel on prod. Esx, these can be ignored.

)WARNING: VMW_SATP_LIB_CX: satp_lib_cx_otherSPIsHung:338:Path "vmhba2:C0:T1:L3" Peer SP is hung.)WARNING: VMW_SATP_LIB_CX: satp_lib_cx_otherSPIsHung:338:Path "vmhba3:C0:T0:L3" Peer SP is hung.)ALERT: NMP: vmk_NmpVerifyPathUID:1166:The physical media represented by device naa.600601609da02e0012ce6a8f930de211 (path vmhba3:C0:T1:L9) has changed. If this is a data LUN, this is a critical error. Detecte[0$)ALERT: NMP: vmk_NmpVerifyPathUID:1166:The physical media represented by device naa.600601609da02e0012ce6a8f930de211 (path vmhba2:C0:T0:L9) has changed. If this is a data LUN, this is a critical error. Detecte[0$)NMP: nmp_DeviceUpdatePathStates:547: Activated path "vmhba2:C0:T1:L9" for NMP device "naa.600601609da02e0012ce6a8f930de211".

- Watch out for messages like this, customers could open cases based on these errors alone…

Page 33: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

33EMC CONFIDENTIAL—INTERNAL USE ONLY

Cleanup – sequence of events [DR ESX]

Page 34: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

34EMC CONFIDENTIAL—INTERNAL USE ONLY

Cleanup – sequence of events [DR VNX]A 10/09/12 14:46:49 4600 'storagegroup' called by ' Navi User admin' (10.64.29.93) with result: Success (Navisphere CLI command: '

storagegroup -removesnapshot -o -gname SG_dellpr710-g.emcvmw.ctc -snapshotname async-25_SRM-TEST-FAILOVER ')A 10/09/12 14:46:50 4600 'Stop' called by 'admin' (10.64.29.93) on 'Session Name: async-25_SRM-TEST-FAILOVER_session' with result: Success (Deactivated snapshot LU successfully: 60:06:01:60:54:50:2E:00:92:7D:58:76:1C:12:E2:11 (async-25_SRM-TEST-FAILOVER_session)Stopped session suA 10/09/12 14:46:50 SnapCopy 71000004 SnapView session async-25_SRM-TEST-FAILOVER_session has been stopped on LUN 25 with status of 0.B 10/09/12 14:46:50 SnapCopy 71000004 SnapView session async-25_SRM-TEST-FAILOVER_session has been stopped on LUN 25 with status of 0.A 10/09/12 14:46:52 SnapCopy 7100000b Snapshot Logical Unit device CopyDisk0000 has been removed.A 10/09/12 14:46:52 NaviCimom 71288021 Failing Command: Set LUN.B 10/09/12 14:46:52 SnapCopy 7100000b Snapshot Logical Unit device CopyDisk0000 has been removed.A 10/09/12 14:46:53 4600 'Destroy a SnapShot' called by 'admin' (10.64.29.93) on 'SnapShot WWN: 60:06:01:60:54:50:2E:00:92:7D:58:76:1C:12:E2:11' with result: Success (Destroy snapshot successfully: 60:06:01:60:54:50:2E:00:92:7D:58:76:1C:12:E2:11)B 10/09/12 14:46:53 NaviCimom 71288021 Failing Command: Set LUN.A 10/09/12 14:47:00 4600 'storagegroup' called by ' Navi User admin' (10.64.29.93) with result: Success (Navisphere CLI command: ' storagegroup -removesnapshot -o -gname SG_dellpr710-g.emcvmw.ctc -snapshotname sync-24_SRM-TEST-FAILOVER ')A 10/09/12 14:47:01 4600 'Stop' called by 'admin' (10.64.29.93) on 'Session Name: sync-24_SRM-TEST-FAILOVER_session' with result: Success (Deactivated snapshot LU successfully: 60:06:01:60:54:50:2E:00:32:0B:08:80:1C:12:E2:11 (sync-24_SRM-TEST-FAILOVER_session)Stopped session succA 10/09/12 14:47:01 Bus1 Enc0 DskE 606 Unit Shutdown for Trespass [ALU 2] 0 ffff0000 2100eA 10/09/12 14:47:01 SnapCopy 71000004 SnapView session sync-24_SRM-TEST-FAILOVER_session has been stopped on LUN 24 with status of 0.B 10/09/12 14:47:01 SnapCopy 71000004 SnapView session sync-24_SRM-TEST-FAILOVER_session has been stopped on LUN 24 with status of 0.B 10/09/12 14:47:01 Bus1 Enc0 DskE 60a A logical unit has been enabled [ALU 2] 0 ffff0000 2100eA 10/09/12 14:47:02 SnapCopy 7100000b Snapshot Logical Unit device CopyDisk0001 has been removed.B 10/09/12 14:47:02 SnapCopy 7100000b Snapshot Logical Unit device CopyDisk0001 has been removed.A 10/09/12 14:47:03 4600 'Destroy a SnapShot' called by 'admin' (10.64.29.93) on 'SnapShot WWN: 60:06:01:60:54:50:2E:00:32:0B:08:80:1C:12:E2:11' with result: Success (Destroy snapshot successfully: 60:06:01:60:54:50:2E:00:32:0B:08:80:1C:12:E2:11)A 10/09/12 14:47:03 RemoteMirror 71050115 MirrorView quiesce LU request.A 10/09/12 14:47:03 RemoteMirror 71050115 MirrorView quiesce LU request.A 10/09/12 14:47:03 RemoteMirror 71050139 RM_ADMIN_INFO_WILL_REBIND the object.A 10/09/12 14:47:03 RemoteMirror 71050111 MirrorView rebind request for LUN 60060160b9502e00:a4cc7fc81507e211.

Page 35: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

35EMC CONFIDENTIAL—INTERNAL USE ONLY

Cleanup – sequence of events [DR VNX]B 10/09/12 14:47:03 RemoteMirror 71050136 Quiesce request from peer SP.

B 10/09/12 14:47:03 RemoteMirror 71050120 Rebind request from peer SP for LUN 60060160b9502e00:a4cc7fc81507e211.B 10/09/12 14:47:03 RemoteMirror 71050136 Quiesce request from peer SP.B 10/09/12 14:47:03 SnapCopy 71000007 SnapView has been unbound from device Disk0001.B 10/09/12 14:47:03 RemoteMirror 71050120 Rebind request from peer SP for LUN 60060160b9502e00:a4cc7fc81507e211.A 10/09/12 14:47:09 4600 'storagegroup' called by ' Navi User admin' (10.64.29.93) with result: Success (Navisphere CLI command: ' storagegroup -removesnapshot -o -gname SG_dellpr710-g.emcvmw.ctc -snapshotname sync-0_SRM-TEST-FAILOVER ')A 10/09/12 14:47:10 4600 'Stop' called by 'admin' (10.64.29.93) on 'Session Name: sync-0_SRM-TEST-FAILOVER_session' with result: Success (Deactivated snapshot LU successfully: 60:06:01:60:54:50:2E:00:54:39:77:89:1C:12:E2:11 (sync-0_SRM-TEST-FAILOVER_session)Stopped session succesA 10/09/12 14:47:10 Bus1 Enc0 DskE 606 Unit Shutdown for Trespass [ALU 3] 0 ffff0001 3100eA 10/09/12 14:47:10 SnapCopy 71000004 SnapView session sync-0_SRM-TEST-FAILOVER_session has been stopped on LUN 0 with status of 0.B 10/09/12 14:47:10 SnapCopy 71000004 SnapView session sync-0_SRM-TEST-FAILOVER_session has been stopped on LUN 0 with status of 0.B 10/09/12 14:47:10 Bus1 Enc0 DskE 60a A logical unit has been enabled [ALU 3] 0 ffff0001 3100eA 10/09/12 14:47:12 4600 'Destroy a SnapShot' called by 'admin' (10.64.29.93) on 'SnapShot WWN: 60:06:01:60:54:50:2E:00:54:39:77:89:1C:12:E2:11' with result: Success (Destroy snapshot successfully: 60:06:01:60:54:50:2E:00:54:39:77:89:1C:12:E2:11)A 10/09/12 14:47:12 RemoteMirror 71050115 MirrorView quiesce LU request.A 10/09/12 14:47:12 RemoteMirror 71050139 RM_ADMIN_INFO_WILL_REBIND the object.A 10/09/12 14:47:12 RemoteMirror 71050111 MirrorView rebind request for LUN 60060160b9502e00:fe606cb30d03e211.A 10/09/12 14:47:12 RemoteMirror 71050115 MirrorView quiesce LU request.A 10/09/12 14:47:12 SnapCopy 7100000b Snapshot Logical Unit device CopyDisk0002 has been removed.B 10/09/12 14:47:12 SnapCopy 7100000b Snapshot Logical Unit device CopyDisk0002 has been removed.B 10/09/12 14:47:12 RemoteMirror 71050120 Rebind request from peer SP for LUN 60060160b9502e00:fe606cb30d03e211.B 10/09/12 14:47:12 RemoteMirror 71050136 Quiesce request from peer SP.B 10/09/12 14:47:12 SnapCopy 71000007 SnapView has been unbound from device Disk0002.B 10/09/12 14:47:12 RemoteMirror 71050120 Rebind request from peer SP for LUN 60060160b9502e00:fe606cb30d03e211.B 10/09/12 14:47:12 RemoteMirror 71050136 Quiesce request from peer SP.

Page 36: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

36EMC CONFIDENTIAL—INTERNAL USE ONLY

Cleanup – sequence of events [PROD]

Page 37: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

37EMC CONFIDENTIAL—INTERNAL USE ONLY

Failover - DEMO

Page 38: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

38EMC CONFIDENTIAL—INTERNAL USE ONLY

Troubleshooting: Obtaining the correct logs

- Ensure to capture the SRM & SRA logs.- Please use VMWare KB 1009253- “Export system Logs”- Please complete these actions on both sites!

- http://kb.vmware.com/selfservice/microsites/search.do?cmd=displayKC&docType=kc&externalId=1009253

Page 39: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

39EMC CONFIDENTIAL—INTERNAL USE ONLY

Troubleshooting: Obtaining the correct logs

If the issue is related to a Test Failover or actual Failover then having the failed Recovery Plan export log will also be invaluable in troubleshooting the issue. To generate the log Export for the failed Recovery Plan:

In the left pane, click Recovery Plans and select the Recovery Plan which had the issue.Select the Plan Name which is showing an Error in the Result column.On the Plan Name with the error click the Export action to generate the report for the failed Test Failover or actual Failover.Save the file to your desktop and upload this file with the SRM system logs.

Page 40: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

40EMC CONFIDENTIAL—INTERNAL USE ONLY

Troubleshooting: Obtaining the correct logs

- Exported information will look like this, take note of the time stamps as this is what we will use to search thru the SPCOLLECT with

- The errors listed here are extremely useful in the actual diagnosis of the issue.

Page 41: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

41EMC CONFIDENTIAL—INTERNAL USE ONLY

Troubleshooting: log files of interest:- There are 2 main folder of interest within the exported log bundles:- The Logs folder surprisingly enough:- This will contain all the activity form the SRM application on that

particular site.- Extract all .gz archives in case the errors you are searching for a

while back….- The mail file of interest in this folder is called “vmware-dr-XX”- Sort by date and review most recent, or search for time stamp

obtained form the html page described on slide 20.

Page 42: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

42EMC CONFIDENTIAL—INTERNAL USE ONLY

Troubleshooting: log files of interest:- Please note the sate in the SRM logs are in the following format

- 2012-09-02T09:10:48.508+01:00- The dates in the exported .html page are in:

- 2012-09-02 09:10:29 (UTC 0)

- So adjust accordingly when searching for errors across logs.- In my example I’ll search thru the SRM logs with :

- 2012-09-02T09

- This will be a good start point- For the Linux heads, this is what I’ using to make the logs more

human readable:

- grep "2012-09-02T09" vmware-dr-3*|grep -v "<" |less

Page 43: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

43EMC CONFIDENTIAL—INTERNAL USE ONLY

Troubleshooting: log files of interest:- Most on the information in these vmware-dr-XX logs are really of

more interest to VMWare than EMC, as its just really verbose logging of the SRM application and database interaction.

- No harm I having a peek to see it there is anything n jumping out though.

- These log flies we want to next focus on is the SRA logs, and there are a few different logs.

- Location = srm-support\Logs\SRAs\EMC VNX SRA

- sra_discoverArrays_08-30-2012_11-12-08.359 - sra_discoverDevices_08-30-2012_12-46-07.042 - sra_failover_08-29-2012_14-34-05.253- sra_prepareFailover_09-02-2012_22-21-46.604- sra_prepareReverseReplication_09-02-2012_22-26-51.711- sra_queryCapabilities_02-24-2012_14-02-20.738- sra_queryConnectionParameters_02-24-2012_14-02-23.035- sra_queryErrorDefinitions_02-24-2012_14-02-25.676- sra_queryInfo_02-24-2012_14-02-09.816- sra_queryReplicationSettings_08-30-2012_17-47-54.968- sra_queryStrings_02-24-2012_14-02-24.160- sra_querySyncStatus_09-02-2012_22-19-09.277- sra_reverseReplication_09-02-2012_22-17-17.440- sra_syncOnce_09-02-2012_22-20-26.700- sra_testFailoverStart_08-29-2012_12-52-23.461- sra_testFailoverStop_09-02-2012_10-21-37.204

Page 44: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

44EMC CONFIDENTIAL—INTERNAL USE ONLY

Troubleshooting: log files of interest:- Timestamp format again is similar here, so just take note of it.- Get timestamp from .html page as before:

- The SRA log folder will be loaded full of many logs so I’m just going to focus on the logs form Sept 02 2012

- The above error was received when trying to do a Test Failover.- We need to check in the following log:

- sra_testFailoverStart_09-02-2012_08-42-09.811.log

- Note the UTC time adjustment.

Page 45: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

45EMC CONFIDENTIAL—INTERNAL USE ONLY

Troubleshooting: log files of interest:- Looking at the log file, we can pull some very useful information:- [sra_testFailoverStart_09-02-2012_08-42-09.811.log]

- grep / search for:

- com.emc.mirrorview.platform.naviseccli.NaviseccliConnection

- This will show the actual navi commands that are being issued by the SRA to the SP

Page 46: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

46EMC CONFIDENTIAL—INTERNAL USE ONLY

Troubleshooting: log files of interest:- Within the same log file search / grep for :

- Command result:

- This should give a clear indication of where the error lies.- In this case, looks like we have a issue with Snapview

Page 47: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

47EMC CONFIDENTIAL—INTERNAL USE ONLY

Troubleshooting: log files of interest:- Switch over to the SPCOLLECT’s for both sites, and grep out any messages

related to SnapCopy- On the DR site, we can see:

- Dave@QQWWQQWW /cygdrive/c/Users/Dave/Documents.backup/Logs/SRM_LOGS_PPTX/Pandora- $ grep SnapCopy "TRiiAGE_full_SPlogs.txt“

- B 09/02/12 07:54:35 NaviCimom 7100808b Failing Command: K10SnapCopyAdmin DBid 0 Op 1046.- A 09/02/12 07:54:43 NaviCimom 7100808b Failing Command: K10SnapCopyAdmin DBid 0 Op 1046.- A 09/02/12 07:54:44 4600 'Create a SnapShot LU' called by 'admin' (10.64.29.93) on

'Navi_SnapCopyFeature' with result: Failure (Could not create SnapShot LU.. [0x7100808B] A SnapView snapshot already exists with the specified name (0x7100808b))

- A 09/02/12 07:54:45 SnapCopy 71008031 You must add LUNs with adequate capacity to the Reserved LUN Pool before you can use this feature.

- A 09/02/12 07:54:46 4600 '' called by 'admin' (10.64.29.93) on 'Navi_SnapCopyFeature' with result: Failure (Could not start SnapView session. Session name - sync-0_SRM-TEST-FAILOVER_session. [0x71008031] You must add LUNs with adequate capacity to the Reserved LUN Pool before you

- A 09/02/12 07:54:46 NaviCimom 71008031 Failing Command: K10SnapCopyAdmin DBid 0 Op 1038.

- This is indicating that there is no Reserve Lun Pool setup, as described on slide 13.

Page 48: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

48EMC CONFIDENTIAL—INTERNAL USE ONLY

Troubleshooting: Logs needed - Recap.• So for all SRM / SRA cases you will need the following logs:

– SPCOLLECT form both sites– SRM logs form both sites– SRA logs form both sites.– “Recovery Plan Export Log.html” as explained on slide 19

• Seriously, don’t proceed until you have everything listed above.

• http://kb.vmware.com/selfservice/microsites/search.do?cmd=displayKC&docType=kc&externalId=1009253

Page 49: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

49EMC CONFIDENTIAL—INTERNAL USE ONLY

Troubleshooting: WorkflowOk, so for every SRM / SRA case that does go in, the following should apply as valid workflow towards resolution of the case.

1. Collect Logs2. Check MirrorView & confirm it is actually working.3. Have customer reconfirm DNS & IP connectivity is OK

1. all hosts should be DNS resolvable on both sites2. All hosts / SP’s should have IP connectivity on same VLAN, all hosts /

SP’s should be able to ping each other…4. Confirm Software requirements listed on Slide 75. Check error that is reported in Recovery Plan Export Log.html6. Search in TRiiAGE_full_Splogs for any errors at the time reported

on the Recovery Plan Export Log.html

Page 50: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

50EMC CONFIDENTIAL—INTERNAL USE ONLY

Log error / message examples

• In this section we will provide examples of errors and informative messages that may assist in troubleshooting your issue.

Page 51: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

51EMC CONFIDENTIAL—INTERNAL USE ONLY

Log error / message examplesSearch for errors that are returned form the Navi commands within the SRA logs.

In particular : look for Command result: stdout(Error:

Search the whole folder of SRA logs as you will get hits on different files depending on the issue you are having.

Some examples: [sra_testFailoverStart_08-30-2012_16-40-15.999.log]

2012-08-30 16:40:31,693 [com.emc.mirrorview.platform.snapshot.HashMapSnapviewSnapshotRepository]: Caching SnapView snapshot with name sync-0_SRM-TEST-FAILOVER2012-08-30 16:40:31,693 [com.emc.mirrorview.platform.snapshot.session.SnapviewSessionServiceImpl]: Starting SnapView session with name: sync-0_SRM-TEST-FAILOVER_session, for snapshot: sync-0_SRM-TEST-FAILOVER2012-08-30 16:40:31,693 [com.emc.mirrorview.platform.naviseccli.NaviseccliConnection]: 10.64.29.85 Executing command: snapview -startsession "sync-0_SRM-TEST-FAILOVER_session" -snapshotname "sync-0_SRM-TEST-FAILOVER" -persistence2012-08-30 16:40:33,003 [com.emc.mirrorview.platform.naviseccli.NaviseccliConnection]: 10.64.29.85 Command result: stdout(Error: snapview command failedYou must add LUNs with adequate capacity to the Reserved LUN Pool before you can use this feature. (0x71008031)), stderr()2012-08-30 16:40:33,003 [com.emc.mirrorview.platform.snapshot.session.SnapviewSessionServiceImpl]: Retrieving info for SnapView session with name sync-0_SRM-TEST-FAILOVER_session2012-08-30 16:40:33,003 [com.emc.mirrorview.platform.naviseccli.NaviseccliConnection]: 10.64.29.85 Executing command: snapview -listsessions -name "sync-0_SRM-TEST-FAILOVER_session"

Page 52: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

52EMC CONFIDENTIAL—INTERNAL USE ONLY

Log error / message examplessra_discoverArrays_08-30-2012_11-15-50.833.log

2012-08-30 11:15:51,457 [com.emc.sra.SraController]: Building SRM command response...2012-08-30 11:15:51,457 [com.emc.sra.ResponseBuilder]: Building discoverArrays response...2012-08-30 11:15:51,473 [com.emc.sra.mirrorview.MirrorviewCommands]: MirrorView Enabler Version: 5.0.222012-08-30 11:15:51,473 [com.emc.mirrorview.platform.naviseccli.NaviseccliConnection]: 10.64.29.85 Executing command: arrayname2012-08-30 11:15:51,504 [com.emc.mirrorview.platform.naviseccli.NaviseccliConnection]: 10.64.29.85 Command result: stdout(), stderr('naviseccli' is not recognized as an internal or external command,operable program or batch file.)2012-08-30 11:15:51,504 [com.emc.mirrorview.platform.naviseccli.NaviseccliConnection]: Unknown error occurred while opening naviseccli connection.2012-08-30 11:15:51,504 [com.emc.sra.mirrorview.MirrorviewCommands]: Unable to connect using SPA, trying SPB...2012-08-30 11:15:51,504 [com.emc.mirrorview.platform.naviseccli.NaviseccliConnection]: 10.64.29.85 Executing command: arrayname2012-08-30 11:15:51,520 [com.emc.mirrorview.platform.naviseccli.NaviseccliConnection]: 10.64.29.85 Command result: stdout(), stderr('naviseccli' is not recognized as an internal or external command,operable program or batch file.)2012-08-30 11:15:51,520 [com.emc.mirrorview.platform.naviseccli.NaviseccliConnection]: Unknown error occurred while opening naviseccli connection.2012-08-30 11:15:51,520 [com.emc.sra.ResponseBuilder]: Unable to get SRA Enabler for this connection info Unable to get SRA Enabler for this connection infocom.emc.sra.ResponseBuilder.getEnabler(ResponseBuilder.java:346)

It would seem form the above that Naviseccli is not installed properly on SRM host, check path!

Page 53: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

53EMC CONFIDENTIAL—INTERNAL USE ONLY

Log error / message examplesIf MirrorView is working is would look like this in sra_discoverDevices_08-29-2012_12-20-26.942.log2012-08-29 12:20:32,823 [com.emc.mirrorview.platform.naviseccli.NaviseccliConnection]: 10.64.29.83 Executing command: mirror -sync -info -systems2012-08-29 12:20:34,102 [com.emc.mirrorview.platform.naviseccli.NaviseccliConnection]: 10.64.29.83 Command result: stdout(Remote systems that can be enabled for mirroring:Remote systems that are enabled for mirroring:Array UID: 50:06:01:60:C7:20:0A:2DStatus: Enabled on both SPs), stderr()2012-08-29 12:20:34,102 [com.emc.sra.response.ReplicatedDevicesBuilder]: Attempted discovery of peer array:50:06:01:60:C7:20:0A:2Dfailed.2012-08-29 12:20:34,102 [com.emc.mirrorview.platform.mirror.MirrorServiceImpl]:************* SYNC MIRRORS ***************2012-08-29 12:20:34,102 [com.emc.mirrorview.platform.naviseccli.NaviseccliConnection]: 10.64.29.83 Executing command: mirror -sync -list2012-08-29 12:20:35,381 [com.emc.mirrorview.platform.naviseccli.NaviseccliConnection]: 10.64.29.83 Command result: stdout(MirrorView Name: Mirror of dellpr710-c.w2k8.emcvmw.ctc Datastore_1MirrorView Description:MirrorView UID: 50:06:01:60:BE:A0:39:93:03:00:00:00:00:00:00:00Logical Unit Numbers: 0Remote Mirror Status: MirroredMirrorView State: ActiveMirrorView Faulted: NOMirrorView Transitioning: NOQuiesce Threshold: 60Minimum number of images required: 0Image Size: 125829120Image Count: 2Write Intent Log Used: YESImages:Image UID: 50:06:01:60:BE:A0:39:93Is Image Primary: YESLogical Unit UID: 60:06:01:60:9D:A0:2E:00:52:49:31:9F:C9:D7:E1:11Image Condition: Primary ImagePreferred SP: A

Image UID: 50:06:01:60:C7:20:0A:2DIs Image Primary: NOLogical Unit UID: 60:06:01:60:B9:50:2E:00:FA:DE:7D:16:AB:F1:E1:11Image State: SynchronizedImage Condition: NormalRecovery Policy: ManualPreferred SP: ASynchronization Rate: MediumImage Faulted: NOImage Transitioning: NOSynchronizing Progress(%): 100), stderr()

Page 54: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

54EMC CONFIDENTIAL—INTERNAL USE ONLY

Log error / message examplessra_discoverDevices_08-29-2012_12-54-59.945.log

2012-08-29 12:55:13,486 [com.emc.mirrorview.platform.snapshot.SnapviewSnapshotServiceImpl]: Retrieving SnapView snapshot information...2012-08-29 12:55:13,486 [com.emc.mirrorview.platform.naviseccli.NaviseccliConnection]: 10.64.29.85 Executing command: snapview -listsnapshots2012-08-29 12:55:13,861 [com.emc.mirrorview.platform.naviseccli.NaviseccliConnection]: 10.64.29.85 Command result: stdout(This version of Core Software does not support Snapview), stderr()2012-08-29 12:55:13,861 [com.emc.mirrorview.platform.snapshot.HashMapSnapviewSnapshotRepository]: Caching SnapView snapshot with name null2012-08-29 12:55:13,861 [com.emc.sra.SraController]: Writing XML response...

In the above example, I did not have the correct Snapview enabler installed on the VNX, there is a new one for INYO.

Reference Slide 7

Page 55: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

55EMC CONFIDENTIAL—INTERNAL USE ONLY

Log error / message examplessra_testFailoverStart_08-30-2012_16-43-48.316.log

2012-08-30 16:43:58,722 [com.emc.mirrorview.platform.snapshot.SnapviewSnapshotServiceImpl]: Retrieving SnapView snapshot information...2012-08-30 16:43:58,722 [com.emc.mirrorview.platform.naviseccli.NaviseccliConnection]: 10.64.29.85 Executing command: snapview -listsnapshots2012-08-30 16:43:59,923 [com.emc.mirrorview.platform.naviseccli.NaviseccliConnection]: 10.64.29.85 Command result: stdout(SnapView logical unit name: sync-0_SRM-TEST-FAILOVERSnapView logical unit ID: 60:06:01:60:54:50:2E:00:78:4E:71:B9:BA:F2:E1:11Target Logical Unit: 0State: Inactive), stderr()2012-08-30 16:43:59,923 [com.emc.mirrorview.platform.snapshot.HashMapSnapviewSnapshotRepository]: Caching SnapView snapshot with name sync-0_SRM-TEST-FAILOVER2012-08-30 16:43:59,923 [com.emc.mirrorview.platform.snapshot.SnapviewSnapshotServiceImpl]: Creating SnapView snapshot with name: sync-0_SRM-TEST-FAILOVER, of LUN: 02012-08-30 16:43:59,923 [com.emc.mirrorview.platform.snapshot.SnapviewSnapshotServiceImpl]: Searching for current SP owner of lun: 02012-08-30 16:43:59,923 [com.emc.mirrorview.platform.naviseccli.NaviseccliConnection]: 10.64.29.85 Executing command: snapview -createsnapshot 0 -snapshotname "sync-0_SRM-TEST-FAILOVER"2012-08-30 16:44:02,029 [com.emc.mirrorview.platform.naviseccli.NaviseccliConnection]: 10.64.29.85 Command result: stdout(Error: snapview command failed A SnapView snapshot already exists with the specified name (0x7100808b)), stderr()2012-08-30 16:44:02,029 [com.emc.mirrorview.platform.snapshot.session.SnapviewSessionServiceImpl]: Starting SnapView session with name: sync-0_SRM-TEST-FAILOVER_session, for snapshot: sync-0_SRM-TEST-FAILOVER2012-08-30 16:44:02,029 [com.emc.mirrorview.platform.naviseccli.NaviseccliConnection]: 10.64.29.85 Executing command: snapview -startsession "sync-0_SRM-TEST-FAILOVER_session" -snapshotname "sync-0_SRM-TEST-FAILOVER" -persistence2012-08-30 16:44:03,355 [com.emc.mirrorview.platform.naviseccli.NaviseccliConnection]: 10.64.29.85 Command result: stdout(Error: snapview command failed You must add LUNs with adequate capacity to the Reserved LUN Pool before you can use this feature. (0x71008031)), stderr()

Both of the above errors were experienced when I did not have the Reserved Pool setup.

Page 56: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

56EMC CONFIDENTIAL—INTERNAL USE ONLY

Log error / message examples [ESX]From the esx side we will see errors in the vmkernel during a HBA rescan of the MirrorView devices:

This is expected behaviour

2012-10-03T13:11:19.187Z cpu9:2057)NMP: nmp_ThrottleLogForDevice:2318: Cmd 0x28 (0x4124413ba440) to dev "naa.60060160b9502e00a4cc7fc81507e211" on path "vmhba5:C0:T0:L5" Failed: H:0x0 D:0x2 P:0x2 Possible sense data: 0x5 0x25 0x1.Act:NONE2012-10-03T13:11:19.187Z cpu9:2057)ScsiDeviceIO: 2316: Cmd(0x4124413ba440) 0x28, CmdSN 0x5c5e6 to dev "naa.60060160b9502e00a4cc7fc81507e211" failed H:0x0 D:0x2 P:0x2 Possible sense data: 0x5 0x25 0x1.2012-10-03T13:11:19.187Z cpu14:2833)Partition: 484: Read of GPT header failed on "naa.60060160b9502e00a4cc7fc81507e211": I/O error2012-10-03T13:11:19.188Z cpu9:2057)ScsiDeviceIO: 2316: Cmd(0x4124413ba440) 0x28, CmdSN 0x5c5e7 to dev "naa.60060160b9502e00a4cc7fc81507e211" failed H:0x0 D:0x2 P:0x2 Possible sense data: 0x5 0x25 0x1.2012-10-03T13:11:19.188Z cpu14:2833)WARNING: Partition: 944: Partition table read from device naa.60060160b9502e00a4cc7fc81507e211 failed: I/O error

Page 57: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

57EMC CONFIDENTIAL—INTERNAL USE ONLY

Log error / message examples [ESX]Taking a closer look at those scsi sense codes:

H:0x0 D:0x2 P:0x2 Possible sense data: 0x5 0x25 0x1

http://10.241.217.72/vmdecoder/index.php

Page 58: VMware vCenter  Site  Recovery Manager  5.x with EMC VNX Arrays & MirrorView

58EMC CONFIDENTIAL—INTERNAL USE ONLY

Questions