19
VITODENS 200 WB2B VITODENS 200 WB2B COMPARISON TO VITODENS 200 WB2A The next generation of VITODENS 200

Upload: jeremiah-ray

Post on 26-Mar-2015

266 views

Category:

Documents


9 download

TRANSCRIPT

Page 1: VITODENS 200 WB2B COMPARISON TO VITODENS 200 WB2A The next generation of VITODENS 200

VITODENS 200 WB2BVITODENS 200 WB2BCOMPARISON TO VITODENS 200 WB2A

The next generation of VITODENS 200

Page 2: VITODENS 200 WB2B COMPARISON TO VITODENS 200 WB2A The next generation of VITODENS 200

# of Models 7 5

Size range MBtu Input

67, 93, 126, 67, 93, 126, 160, 212, 285, 160, 212, 285,

37037091, 124, 172, 230

Fuels

NG, LPG up to LPG up to 212212

NG 285 & 370NG 285 & 370(With Lambda-Pro(With Lambda-Pro)

NG, LPG(de-rated with LPG)

AFUE 96.1%96.1% 95.2%

Altitude Up to 10,000 ft.Up to 10,000 ft. Up to 10,000 ft.

NEW!NEW!200WB2B

200WB2A

The next generation of VITODENS 200

Page 3: VITODENS 200 WB2B COMPARISON TO VITODENS 200 WB2A The next generation of VITODENS 200

Stainless steel Heat exchanger

Inox Radial design SA240 316Ti Refractory front Refractory front

and backand back

Inox Radial design SA240 316Ti Wet Back

Modulation Burner

MatriXMatriX Cylinder NG, LPGLPG

MatriX Dome NG, LPG(De-rated with LPG)

Venting optionsHorizontal and Vertical

Coaxial Double pipe Single pipe Up to 180’ Up to 180’

equivalent lengthequivalent length

Coaxial Double pipe Single pipe Up to 79’

equivalent length

The next generation of VITODENS 200

NEW!NEW!200WB2B

200WB2A

Page 4: VITODENS 200 WB2B COMPARISON TO VITODENS 200 WB2A The next generation of VITODENS 200

Boiler & system control VitotronicVitotronic Comfortrol

Outdoor reset YesYes Yes

DHW control YesYes YesMixing valve control Yes Yes

Cascade control Vitotronic 300KVitotronic 300KVitocontrol-S

WB2

The next generation of VITODENS 200

NEW!NEW!200WB2B

200WB2A

Page 5: VITODENS 200 WB2B COMPARISON TO VITODENS 200 WB2A The next generation of VITODENS 200

# of Cascaded boilers 44 4

Lambda-Pro combustion control

YesYes No

Gas pressure required

All sizesAll sizes

NG 4”-14”NG 4”-14”

LPG 10”-14”LPG 10”-14”

6-24 to 11-44NG 4”-14”

15-60NG 7”-14”All sizes

LPG 11”-14”

The next generation of VITODENS 200

NEW!NEW!200WB2B

200WB2A

Page 6: VITODENS 200 WB2B COMPARISON TO VITODENS 200 WB2A The next generation of VITODENS 200

VITODENS 200 WB2B

Top 10 New Features10 New Features

MatriX Cylinder burner.MatriX Cylinder burner.

Up to 180 Ft. equivalent vent Up to 180 Ft. equivalent vent lengths lengths (previously 79 Ft).

Lambda-Pro combustion Lambda-Pro combustion management.management.

Vitotronic Boiler & System controlVitotronic Boiler & System control

Page 7: VITODENS 200 WB2B COMPARISON TO VITODENS 200 WB2A The next generation of VITODENS 200

VITODENS 200 WB2B

Top 10 New Features10 New Features

All in the box packagingAll in the box packaging Boiler, Vitotronic 200 Control Lambda-Pro installation fittings DHW Kit North American manuals.

4”wc minimum gas pressure on all 4”wc minimum gas pressure on all models in NG.models in NG.

Page 8: VITODENS 200 WB2B COMPARISON TO VITODENS 200 WB2A The next generation of VITODENS 200

VITODENS 200 WB2B

Top 10 New Features10 New Features

AFUE 96.1 AFUE 96.1 (up from 95.2).(up from 95.2).

Increased capacity selection Increased capacity selection 67 - 370 MBH, (previously, (previously

91 - 230 MBH).91 - 230 MBH).

Altitudes up to 10,000 feet with all Altitudes up to 10,000 feet with all fuels.fuels.

No capacity reduction for LPG.No capacity reduction for LPG.

Page 9: VITODENS 200 WB2B COMPARISON TO VITODENS 200 WB2A The next generation of VITODENS 200

VITODENS 100 / 200

The next generation of Vitodens!The next generation of Vitodens!

WB1B WB2B

Page 10: VITODENS 200 WB2B COMPARISON TO VITODENS 200 WB2A The next generation of VITODENS 200

VITODENS 100 WB1BVITODENS 100 WB1BCOMPARISON TO VITODENS 100 WB1A

The next generation of VITODENS 100

Page 11: VITODENS 200 WB2B COMPARISON TO VITODENS 200 WB2A The next generation of VITODENS 200

# of Models 2 2

Size range MBtu Input

91, 11891, 118 80, 100

Fuels

NG, LPGLPG(conversion kit (conversion kit supplied with supplied with

boilerboiler)

NG only(no LPG kit available)

AFUE 95.2%95.2% 95.1%

Altitude Up to 10,000 ft.Up to 10,000 ft. Up to 5,000 ft.

NEW!NEW!100WB1B

100WB1A

The next generation of VITODENS 100

Page 12: VITODENS 200 WB2B COMPARISON TO VITODENS 200 WB2A The next generation of VITODENS 200

Stainless steel Heat exchanger

Inox Radial design SA240 316Ti Refractory front

and back

Inox Radial design SA240 316Ti Refractory front

and back

Modulation Burner

MatriXMatriX Cylinder NG, LPGLPG

Cylinder NG

Venting optionsHorizontal and Vertical

Coaxial Double pipe Single pipe Up to 200’ Up to 200’

equivalent lengthequivalent length

Coaxial Double pipe Single pipe Up to 79’

equivalent length

NEW!NEW!100WB1B

100WB1A

The next generation of VITODENS 100

Page 13: VITODENS 200 WB2B COMPARISON TO VITODENS 200 WB2A The next generation of VITODENS 200

OpenTherm compatible interface

Yes Yes

Outdoor resetYesYes

(OA sensor (OA sensor includedincluded)

No

0-10VDC inputYesYes

(No extra module (No extra module required)required)

Yes(Through separate OT

module) $300.00

DHW / External heat demand

Yes (Through DHW dry contact closure)

Yes(Through DHW dry contact closure)

DHW / External heat demand set point

Fixed172°F, 78°C

Fixed172°F, 78°C

100WB1A

NEW!NEW!100WB1B

The next generation of VITODENS 100

Page 14: VITODENS 200 WB2B COMPARISON TO VITODENS 200 WB2A The next generation of VITODENS 200

Air proving switch Not RequiredNot Required Yes

All in the box packaging YesYes No

Pump control

Flue Gas Temperature limit sensor

Boiler pump

YesYes

Boiler pump

No

100WB1A

NEW!NEW!100WB1B

The next generation of VITODENS 100

Page 15: VITODENS 200 WB2B COMPARISON TO VITODENS 200 WB2A The next generation of VITODENS 200

On/off switch YesYes No

Screen display 1 line text with additional symbols

1 line text with additional symbols

Burner firing rate display

Yes – bar chart Yes – bar chart

Status display Burner status

Faults / diagnosticsBoiler temp

Burner statusFaults / diagnostics

Water pressureBoiler temp

100WB1A

NEW!NEW!100WB1B

The next generation of VITODENS 100

Page 16: VITODENS 200 WB2B COMPARISON TO VITODENS 200 WB2A The next generation of VITODENS 200

VITODENS 100 WB1B

Top 10 New Features10 New Features

Larger capacities 118 MBH Larger capacities 118 MBH ((up from 100 MBH).

NG & LPG – NG & LPG – ((boiler includes LPG boiler includes LPG conversion kit).conversion kit).

95.2 AFUE.95.2 AFUE.

Altitudes up to 10,000 Ft.Altitudes up to 10,000 Ft.

Page 17: VITODENS 200 WB2B COMPARISON TO VITODENS 200 WB2A The next generation of VITODENS 200

VITODENS 100 WB1B

Top 10 New Features10 New Features

MatriX Cylinder burner.MatriX Cylinder burner.

Up to 200 Ft. Equivalent vent Up to 200 Ft. Equivalent vent lengths lengths (up from 79 Ft).

OA Reset control standard OA Reset control standard (OA sensor included).

0 - 10 VDC control standard 0 - 10 VDC control standard (no additional modules required).

Page 18: VITODENS 200 WB2B COMPARISON TO VITODENS 200 WB2A The next generation of VITODENS 200

VITODENS 100 WB1B

Top 10 New Features10 New Features

All in the box packagingAll in the box packaging Boiler, OA reset control c/w sensor, OpenTherm communication, 0-10 VDC input, installation fittings, LPG conversion kit, North American manuals.

Flue gas temperature limit sensor Flue gas temperature limit sensor (additional level of safety).

Page 19: VITODENS 200 WB2B COMPARISON TO VITODENS 200 WB2A The next generation of VITODENS 200

Our premium state of the art wall hung condensing boiler…

The Best wall hung condensing boiler The Best wall hung condensing boiler on the market!on the market!

Unique burner technology Unique burner technology advancements!advancements!