VISONIC 2008

Page 2: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Technical Presentation

Erik NilssonProduct ManagerVisonic Group, Nordic Region

Page 3: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control
Page 4: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Powermax Pro ArchitectureSystem ArchitectureControl With ..

MKP 1502 Way Wireless Keypads

MCM 140Wireless Keypads

MCT 234 / MCT 237Wireless Keyfob / 2 Way Keyfob

Proximity TagsX-10 TM

HomeAppliances

EnergyManagement

Lights 2 Way Dimming

Home Control

8 Users Codes + Duress CodeInternal GSMRFID Reader

Internal IP Connectivity & Control

Alarm Notification

MCS 700 / 710Wireless External

Sirens

Web Control

E-mail Alert*

SMS*

Private Phone28 Wireless Zones + 2 Wired Zones

Detectors & Devices

8x

2x

8x

8x 2x

Up to 15

* Region dependable

Page 5: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

System Configuration

Page 6: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

System Configuration

Modular System Configuration

System parts:

Prox Reader GSM module Backup Battery Main Board Dual RS232 module Audio module

Power Supply - PowerLink module

Page 7: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Mounting of Panel on wall

1

2

5Fasten the back unit with 4 screws

4Drill 4 holes and insert wall anchors

Releasescrews

3Back unit

Mark 4 drilling points on mounting surface

Page 8: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Connecting Power cable

Safetycover

Power cable clamp options

(*)Powersupply

unit

For thincable

For thick cable(reversed clamp)

Extract either ofthese cable clampsfor use in the nextstep.

Thick cable entry: Pull out adesired wiring plastic cap (1of 4).

Small wiring plastic cap forthin cable entry: Break thesmaller section of the wiringplastic cap and insert thewiring plastic cap back into itsplace.

1

2

Enter power cable through the desired wiring channel (see step 1), route it tothe power supply unit and connect its 2 wires to the power supply terminal stripwith screwdriver. Fasten power cable by its clamp (see also step 2 - this clampcan be reversed to fit thick/thin cable) and close the safety cover.

OPTIONAL PLUG-IN POWER SUPPLYConnect the power connector (optional) to the powersupply unit.

3 4(*)

Powersupply

unit

Page 9: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Zones and Sirens wiring

SITEINTERNALSIREN ORSTROBE

SITEEXTERNAL

SIREN

SRNEXT

+12VSRNINT

PGM+12VGNDZONE30

GND V+ZONE29

ZONES

NoteRegarding zones 29 & 30, the ControlPanel “sees” a specific resistanceaccording to the event, as follows:Normal (no alarm & no tamper): 2.2 kΩAlarm event: 4.4 kΩTamper event: Infinite resistance

CONNECT WIRED DETECTORS AS FOLLOWS:

(*)

Power

ZONE 29 /ZONE 30 GND

TAMPN.C.

V+(*)

AlarmN.C.

ZONE 29 /ZONE 30

Power

GND

2.2 kΩ

V+

AlarmN.C.

Detector withTamper switch

Detector withoutTamper switch

ZONES & SIRENS WIRING

NOTE!Zones 29 and 30 must beEnrolled to be activated.

Go to Enrolling of detectors.Select zone 29/30 and Enroll.

Page 10: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

GSM modem unit & SIM Card

GSM FrontunitExternal GSM

antenna(optional)

1Slide top

cover

Lock coverto close

6

SIM card insertion

IMPORTANT1.Before inserting SIM

card, deactivate itsPIN code (by using acellular telephone).

2.Do not insert orremove SIM cardwhen the PowerMaxPro is Powered by ACpower or battery.

4Slide SIMcard into

cover

5Rotate cover

to close

2Opencover

Align SIMcard in cover(note coverorientation)

3

Page 11: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Serial Connection to PC

Pull out the plastic cap. Insert the RS-232 adapter and secure it with the screw. Break the smaller section of the removed plastic cap and insert it back into its place.

Page 12: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Keypad

VOLUME UP / LIGHT BRIGHT

EMERGENCY(Hold for 2 sec.)

PLAY MESSAGEVOLUME DOWN / LIGHT DIM

CHIME ON/OFFMUTE SPEAKER

EVENT LOGNO ENTRY DELAY

RECORD MESSAGE

ARM TROUBLECHIMEPOWER

LIGHT ON

LIGHT OFF

LIGHT CONTROL

TESTING

ARMING “AWAY”

ARMING “HOME”

DISARMING

MOVE BACK

FIRE (Holdfor 2 sec.)

Press bothfor panic

alarm

SHOW/OKNEXT

INDICATORS

DISPLAY

Page 13: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

PowerMax Pro Enrolling & Programming

Page 14: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Menu System

Page 15: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Enrolling of Wireless devices

• Wireless Devices– 28 different PowerCode Detectors & portable transmitters

• Keyfobs & Wireless remote commander

– 8 CodeSecure Keyfobs– 8 CodeSecure 1-way Keypad Commanders– 2 two-way Wireless Control Keypads– 2 two-way Wireless Sirens

Page 16: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Enrolling

Page 17: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Enrolling

Page 18: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Interior

Perimeter

Delayed Zones

Interior follow

24 Hour Audible

24 Hour Silent

Fire/Flood/Gas

Non-Alarm

Emergency

12 different zone types

Protect rooms inside protected area.

Protect doors, windows and walls.

PANIC buttons, perimeter detectors and anti-tamper protection. They trigger an alarm in both armed and disarmed states.

Exit delay begins once the user armsthe system. Entry delay begins once the user is sensed by a delay zone detector.

A non-entry/exit zone, typically an interior zone located on an entry/exit path that is treated as an entry/exit zone during an entry/exit time.

Uses Special purpose detectors and are permanently active. Will announce nature of alert.

Used for auxiliary remote control tasks such as PGM or X-10 units opening / closing a gate, activating /deactivating a courtesy light and similar applications. No alarm.

For Social Alarms. On activation PowerMax will send an emergency call to the central monitoring station.

As above but on activation no Siren will sound but PowerMax will initiate a call to the central monitoring station.

Perimeter followA non-entry/exit zone, typically a perimeter zone located on an entry/exit path, that is treated as an entry/exit zone during an entry/exit time.

Page 19: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

AtticAttic

BasementBasement

Back DoorBack Door

BathroomBathroom

BedroomBedroom

Child RoomChild Room

ClosetCloset

DenDen

DownstairsDownstairs

Dining RoomDining Room

EmergencyEmergency

Front DoorFront Door

FireFire

Garage Garage

Garage DoorGarage Door

Guest RoomGuest Room

HallHall

KitchenKitchen

Living RoomLiving Room

Laundry RoomLaundry Room

Master BathroomMaster Bathroom

OfficeOffice

Master BedroomMaster Bedroom

UpstairsUpstairs

Utility RoomUtility Room

YardYard

Custom 1- 5Custom 1- 5

26 Zone names and 5 Custom names

(5 Custom Zone namesProgrammable from SW)

Page 20: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Default Zone definitionsZone Type Name 1 Delay 1 Front door2 Delay 1 Garage3 Delay 2 Garage door4 Perimeter Back door5 Perimeter Child room6 Interior Office7 Interior Dining room8 Perimeter Dining room9 Perimeter Kitchen10 Perimeter Living Room11 Interior Living Room12 Interior Bedroom13 Perimeter Bedroom14 Perimeter Guest Room15 Interior Master Bedroom16 Perimeter Master Bedroom17 Perimeter Laundry room18 Perimeter Master Bathroom19 Perimeter Basement20 Fire Fire21 Fire Fire22 Emergency Emergency23 Emergency Emergency24 24 h/silent Basement25 24 h/silent Office26 24 h/audible Attic27 24 h/audible Den28 non-alarm Yard29 non-alarm Hall30 non-alarm Utility room

If the default Zone Types and Names fit your installation, you just have to determine for each detector, which zone it will be placed in, enroll it, and you are done.

Zone No. 31 = WL siren 1 (MCS-700/710)Zone No. 32 = WL siren 2 (MCS-700/710)Zone No. 33 = GSMZone No. 34 = 2-W-KP (1) (MKP-150)Zone No. 35 = 2-W-KP (2) (MKP-150)

Page 21: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Zone programming

Page 22: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

• It is possible to define a “Chime” feature zone by zone.

• The general “chime” feature (key “8”) on the keypad must be “on”.

Chime per Zone

(green Chime Icon “on”)

Page 23: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Panel Definitions1. Entry Delay 1 00s, 15s, 30s, 45s, 60s, 3m, 6m 2. Entry Delay 2 00s, 15s, 30s, 45s, 60s, 3m, 6m 3. Exit Delay 30s, 60s, 90s, 120s, 3m, 4m4. Bell Time 1m, 3m, 8m, 10m, 15m, 20m5. Abort Time 00s, 15s, 30s, 45s, 60s, 3m, 4m6. Alarm Cancel Time 1m, 5m, 15m, 60m, 4h, OFF7. Quick Arming ON, OFF8. Bypass manual bypass, no bypass, force arm9. Restart Exit Restart ON, restart OFF10. Piezo Beeps enable beeps, off when home, disable beeps11. Trouble Beeps enable beeps, off at night, disable beeps12. Panic Alarm enable panic, disable panic13. Swinger Stop shut after 1, shut after 2, shut after 3, no shutdwn14. Cross Zoning ON, OFF15. Supervision Interval 1h, 2h, 4h, 8h, 12h, disable16. AUX Button status, instant, PGM/X-1017. Jamming Detection ON, OFF18. 2-Way Voice - Private Tel. ON, OFF19. 2-Way Voice - Central Station 10s, 45s, 60s, 90s, 2m, OFF20. PGM / X-10 Time Pulse time 2s, 30s, 2m, 4m, toggle21. Lighting Lockout Time Start/stop time for X-10 devices.22. Latchkey Arming ON, OFF23. Not Active. Time 3h, 6h, 12h, 24h, 48h, 72h, disabled24. Back Lighting always on, off after 10s25. Duress Alarm (ambush) 4 digit code for duress (2580)26. Piezo Siren ON, OFF

Page 24: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

European (and US) time & date format

• U S - F O R M A T: 1 2 H

T I M E: 1 2 : 5 5 AD A T E: M M / D D / Y Y Y Y

• E U - F O R M A T: 2 4 H

T I M E: 1 9 : 5 5D A T E: D D / M M / Y Y Y Y

Page 25: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Automatic arming

You can determine that the system will be automatically armed at any desired time.

• Arming time is entered once.

• AUTO ARM can now be set:– ON and OFF

Useful for office and shop applications

Page 26: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Exit Mode

Here you determine whether the exit delay will restart if theexit / entry door is reopened before the exit delay expires.Restarting the exit delay is helpful if the user re-entersimmediately after going out to retrieve an item that he leftbehind.

Three types of exit mode are available:

Restart Exit - Exit delay restarts when the door isreopened during exit delay. The restart occurs once only.

Off by door - When the door is closed, the exit delay isautomatically terminated (even if the defined exit delaywas not completed).

Normal - The exit delay is exactly as defined, regardlessof whether the door is open or closed.

Page 27: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Alarm Delay / Cancel Alarm

Alarm DelayThe PowerMax is programmed to provide an “abort interval” that starts upon detection of an alarm.

During this interval, the buzzer sounds a warning but the siren remains inactive and the alarm is not yet reported.

If the user disarms the system within the allowed abort interval, the alarm will be aborted.

Cancel AlarmYou can determine a “cancel alarm” period that startsupon reporting an alarm to the central station.

If the user disarms the system within that time period, a “cancel alarm” message will be sent to the central station.

Page 28: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Not Ready Mode

Here you determine if the system will go into the NOT READY status when there is a supervision failure.

• In the "in supervision" mode, the system will go into the NOT READY status if during the last 20 minutes a supervision message was not received.

• Options: normal and in supervision.

Page 29: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Reset option

Here you determine whether the system can be rearmed (after an event) by the user or only by the installer.

• Options: user reset or engineer reset.

• If Engineer Reset is selected, the system can be rearmed only by the installer; by entering and exiting the installer menu, by entering and exiting the event log, or by remote telephone.

• To perform Engineer Reset via the telephone, establish communication with the PowerMax+ and continue as follows:

• a. [*], [installer code], [#]• b. Wait for 2 beeps• c. [*], [1], [#]• d. [*], [99], [#]

Page 30: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Tamper & Siren online failure options

Tamper Option• Here you determine whether zone tamper will be reported or ignored. The available

options are: • Zone tamper ON and zone tamper OFF.

Siren on line failure option• Here you determine whether the siren will be activated or not when the telephone line

fails during system armed state. Available options are: • Enable on fail, and disable on fail.

Page 31: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Memory Prompt & Disarm options

Memory Prompt• Here you determine whether the PowerMax+ will indicate in the display that an alarm

has been activated.• The available options are: enable and disable.

Disarm Option• Here you determine when it is possible to disarm the system:• A. Any time.

• B. During entry delay, by using the PowerMax+ keypad or wireless device (keyfob).

• C. During entry delay, by using a wireless device (keyfob) only.

• D. During entry delay, by using the PowerMax+ keypad in AWAY mode.

Page 32: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Bell / report of supervision/jamming option

• Here you determine whether an alarm will be initiated with siren and reporting when there is a supervision or jamming failure during AWAY arming state.

• The available options are: EN standard and Off.

• When "EN standard" is selected, and if there is supervision or jamming failure during AWAY arming state, the siren is activated and the events are reported as tamper events.

• When "Off" is selected this function is disabled.

Page 33: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Low battery alert for keyfobs

• Here you determine whether the user will hear or will not hear low battery sound when he tries to disarm the system with a keyfob whose battery voltage is low.

• Available options are: keyfob L-B on (the user must acknowledge the keyfob low battery message) or

• Keyfob L-B off (the user does not have to acknowledge the keyfob low battery message).

• When the option is ON, the Keyfob low battery event will be logged in the event log.

Page 34: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Screen saver options

• Here you can determine that if no key is pressed during more than 30 seconds, the display will show “PowerMax” and the LED’s will not light (to prevent possible intruder of knowing the system status).

• You can determine that normal display will return after pressing the OFF button followed by entering user code (Refresh by Code) or

• after pressing any key (Refresh by Key).

• If Refresh by Key is selected, the first pressing of any key (except Fire and Emergency) will cause normal display return and the second press will perform the key function.

• For Fire and Emergency keys, the first key press will cause normal display return and also will perform the Fire/Emergency function.

• Options: screen saver OFF, refresh by code, refresh by key.

Page 35: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Confirmed alarm options

• Here you determine that if 2 successive alarms will occur during a specific period, the second alarm will be considered as a confirmed alarm

• Options: disable 30 min., 45 min., 60 min., or 90 min.

Report confirmed alarm• Here you determine whether the system will report a confirmed

alarm event.

• Available options are: enable report, disable report, enable + bypass

• (enabling report and bypassing the detector applicable to PowerMax+ that is compatible with DD423 standard).

Page 36: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

AC failure report & User permission for installer

AC Failure report interval• Here you determine the time interval between AC power failure

occurrence and the failure reporting. • Options: 5 minutes, 30 minutes, 60 minutes or 180 minutes.

User permission• Here you determine whether the access to the• INSTALLER MODE requires user permission. If you• select ENABLE, the installer mode will be accessible• only through the user menu after entering the user• code.• Options: Enable, Disable.

Page 37: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Two-way voice options for C.S.

Send 2wv code• Here you determine whether the system will send two-way voice code to the central

station (to turn the central station from data communication to voice communication state) by using pre-selected SIA or Contact-ID communication format.

• Options: send and don't send.

2wv with Central Station• Here you select the timeout for 2-way voice communication with Central Stations, or

enable the central station to ring back for 2-way voice function. This option is applicable only after reporting an event to the central station. (The central station person can press [3] for listen-in", [1] for "speak out” or [6] for listening and speaking).

• The options are: 10, 45, 60, 90 seconds, 2 minutes, ring back and disable (no two-way voice communication).

Ring Back Time• Here you determine the period during which the central station can establish 2-way

voice communication with the PowerMax Pro (after 1 ring), if:• A. Alarm type message was received by central station.• B. Ring Back function was selected• The options are: 1, 3, 5 or 10 min.

Page 38: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Unit ID, Zone restore & Upload options

Unit ID• For future use - identification code for PowerMax Pro system that

is connected with several systems in a network

Zone Restore• Here you determine whether a zone restore will be reported or

not.• Options: report restore and don't report.

Upload Option• Here you determine whether the PowerMax Pro data can be

uploaded into a computer while the system is in disarm state or at any time (in HOME/AWAY arming & disarm state).

• The options are: when system OFF and any time.

Page 39: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Line failure report options & UL/DL server options

Line Failure Reporting• Here you determine if the telephone line disconnection will be

reported or not (LED and beep) and determine the delay between detection of line disconnection and the failure reporting. If the telephone line is disconnected, the message "tel line fail" will be stored in the event log.

• The options are: don't report, immediately, 5 minutes, 30 minutes, 60 minutes or 180 minutes.

UL/DL Tel. Number• Here you enter the telephone number (up to 16 digits)• of the UL/DL server.

Page 40: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

System inactive report & Output siren/strobe

System Inactivity report• Here you determine whether the central station will receive a

message if the system is inactive (not armed) during a defined period (days)

• The options are: disable, rep. after 7d, rep. after 14d, rep. after 30d, rep. after 90d.

Defining INT/STRB• Here you determine if the INT output will be for:• Internal siren or for strobe.

Page 41: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Serial number & Reset to factory defaults

Reset to Factory defaults• If you want to reset the PowerMax Pro parameters to the factory

default parameters, enter the installer menu and perform the “11. FACTORY DEFLT" function by entering the required code.

• Note: For PowerMax Pro with 2 installer codes, INSTALLER code and MASTER INSTALLER code, only the master installer code enables to perform factory default function.

Serial Number• The menu "12. SERIAL NUMBER" enables reading the system

serial number for support purposes only. • If GSM is connected, it’s serial number can also be inspected

here.

Page 42: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Piezo Beeps:Piezo Beeps:

• Enable beeps Enable beeps

• Off when home Off when home

Trouble Beeps:Trouble Beeps:

• Disable beeps Disable beeps

• Enable beeps Enable beeps

• Off at night (8PM Off at night (8PM to 7AM) to 7AM)

• Disable beeps Disable beeps

Piezo and trouble beeps

Here you determine whether warning beeps will sound or will be muted throughout the exit and entry delays. An additional option is to mute the warning beeps only whenthe system is armed HOME.

Under trouble conditions, the sounder emits a series of 3 short beeps once per minute. Here you determinewhether this special beeping sequence will be active, inactive, or just inactive at night (the range of .night. hours is defined in the factory).

Page 43: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Swinger Shutdown

• This parameter will determine how many times each zone is allowed to initiate an alarm within a single arming period.

• If the number of alarms from a specific zone exceeds the number programmed in this location, the control panel will automatically bypass the zone to prevent recurrent siren noise and nuisance reporting to the central station.

• The zone will be reactivated upon disarming, or 48 hours after having been bypassed (if the system remains armed).

• The available options are:

• shut after 1 alarm• shut after 2 alarms• shut after 3 alarms• no shutdown.

Page 44: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Cross Zone Alarm

• Cross Zone Alarm is a method used to prevent false alarms as a result of faulty operation or in problematic zones.

• An alarm will not be initiated unless two adjacent zones are violated within a 30-second time limit.

• This feature is active only when arming AWAY and only with zone couples from zone No. 20 up (20 and 21, 22 and 23, etc.).

• You may use any one of these zone couples to create a cross-zoned area.

• Note: If one of two crossed zones is bypassed the remaining zone will function independently.

Page 45: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

If no movement is detected from any interior If no movement is detected from any interior zone within the time defined, a “No Active” zone within the time defined, a “No Active” alarm will be initiated:alarm will be initiated:

• 3 Hours

• 6 Hours

• 12 Hours

• 48 Hours

• 72 Hours

• Disabled

• 24 Hours

No activity time

Page 46: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Communication definitions

1. Dialing method tone (dtmf), pulse2. Phone Line Test Interval 1d, 5d, 7d, 30d, OFF3. 1st. Central Station Tel. No. Enter number4. 1st. Account No. Enter number5. 2nd. Central Station Tel. No. Enter number6. 2nd. Account No Enter number7. Report Format contact ID, SIA, 4/2 1900/1400, 4/2 1800/23008. 4/2 Pulse Rate -9. Reporting to Central Stations all –o/c *Backup10. Dialing Attempts 2, 4, 8, 12, 1611. First Private Tel. No. Enter number12. Second Private Tel. No. Enter number13. Third Private Tel. No Enter number14. Telephone Message Type tone, voice15. Private Tel. Dialing Attempts 1, 2, 3, 416. Reporting to Private Tel. All, alm+alrt, alm+op/cl, alm, alerts, op/cl, disable17. Telephone Acknowledge single ack, all ack18. Pager Telephone Number Enter number19. Pager.s PIN No -20. Reporting to a Pager All, alm+alrt, alm+op/cl, alm, alerts, op/cl, disable21. Recent Closure ON, OFF22. Remote Access ON, OFF23. Downloader Code Enter 4 digit code

Page 47: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Central Station Report Protocols

Contact ID

SIAPulse 4/2 1900/1400

Pulse 4/2 1800/2300

Scancom

Page 48: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Central station report option

Plan name Sent to center 1 Sent to center 2all * backup All events All if center 1 does not respond all -o/c * backup All but open/close All if center 1 does not respond all * all All events All eventsall * -o/c all -o/c All but open/close All but open/closeall -o/c * o/c All but open/close open/close onlyall -alrt * alrt All but alerts Alertsalrm * all -alrm Alarms All but alarmsdisable Nothing Nothing

Note: .All. means that all 3 groups are reported and alsotrouble messages - sensor / system low battery, sensorinactivity, power failure, jamming and communication failure.

GROUP EVENTS REPORTED1. Alarms Fire, Burglary, Panic, Tamper2. Open/Close Arming AWAY, Arming HOME, Disarming3. Alerts No-activity, Emergency, Latchkey

Group 1 has the highest priority and group 3 has the lowest priority.

Page 49: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Private tel. Report option

• The options are:• All (-trouble)• Alarms + alerts• alarms + open/close• Alarms• Alerts• Open/close• Disable report.

• Note: “All” means all events including Low Battery and AC Failure events

• If no telephone Line is connected to the PowerMax+, the Line Fail Report option must be set to “Don’t Report”, otherwise you will get a Telephone Line Failure Alert and the PowerMax+ will start beeping.

Page 50: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Download Codes

• The Download Codes are 4-digit password Codes for gaining access to downloading data into the PowerMax memory from the Remote PC program.

• The same download Code must be entered into the PC program before connecting to this site.

• Two Download codes are possible: Master and Installer Download Code– Master Code: Full Acess– Installer Code: Limited Access to Communication setup

• Remote Access to the PowerMax will only be possible if access has been granted in the PowerMax Setup menu: Remote Access

• Attention! Do not use 0000 - this code is invalid.

Modem Tel LineRS232

Page 51: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

X-10 / PGM operation modes

• For each X-10 unit you can select disable, turn on, turn off or pulse active, upon the following conditions:

• By arming, arming home, disarming

• By Alarm in memory: Activated upon registration of an alarm in the memory, turned off upon memory clearing.

• By delay: During the exit and entry delays.

• By keyfob: upon AUX button pressing the keyfob/MCM-140+, if “PGM/X-10” is selected in Define Panel menu.

• By zones: By disturbance in each of 3 selected zones, irrespective of arming / disarming.

• For keyfob and zone control also toggle function can be selected.

• By Schedule: Up to 4 ON/OFF time zones per unit per day.

• PGM only: ON by Line Fail: PGM output goes ON if telephone line is disconnected.

• Note: The PGM / X-10 outputs may be programmed for activation by any combination of factors.

Page 52: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

TW-7223 Power Line Interface

Links the PowerMax to the power network through 2-way X-10 protocol

X-10 units for 1 and 2-way communication

FD10 DIN Filter/Coupler3 phase coupler will branch traffic between phases.

Filters traffic from going out of local Power Installation

Page 53: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

X-10 units for 1 and 2-way communication

AM-12 Appliance Module

Lamps and low power devices

LW10 Wall Dimmer, Max 500W

Replaces any normal dimmer for X-10 control of branch lighting circuit rated between 60 W and 500 W.

Page 54: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

X-10 units for 1 and 2-way communication

Very small appliance modules.Micro modules are designed to fit behind the switch. The lights and appliances connected to the module can be controlled by the an X-10 system as well as a normal switch.

Page 55: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

GSM Unit

The GSM unit enables the PowerMax+ system to operateover cellular network. GSM unit features are as follows:

• PowerMax+ fast upload/download capability via the GSM unit.• Sending SMS and voice messages to private telephones.• Communication with central station (SIA, Contact ID format).• Serving as PowerMax+ telephone line backup, as a primary communication channel,

or as the only telephone channel.• Sending SMS messages to central station.• Two-way audio communication between telephone user and PowerMax+ user.• PowerMax+ remote arming.• Remote activation of home appliances.• Remote PowerMax+ system monitoring (status, failures).• Enables calling the PowerMax+ by a single dialing (it is not necessary to dial, hang up

and then redial).• Tamper and line disconnection protection.

Page 56: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

GSM Programming

The GSM Programming mode is applicable only if the PowerMax+ is connected to the GSM unit.

Programming options are:

• Define that the GSM unit is installed / not installed.• Define 4 private SMS phone numbers to which events will be reported.• Define which types of events will be reported to SMS• phone numbers.• Define whether the GSM unit will serve as:

– backup for the regular telephone line– primary communication channel– the only telephone channel or – for sending SMS only.

• Define whether GSM line failure will not be reported, or will be reported after 2, 5,15 or 30 minutes.

Page 57: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

GSM Reporting

Event messages are divided by type into three groups:

GROUP EVENTS REPORTEDAlarms Fire, Burglary, Panic, TamperOpen/Close Arming AWAY, Arming HOME, DisarmingAlerts No-activity, Emergency, Latchkey

The selectable report options are:Option DescriptionAll All event typesall (-op/cl) All event types except open/closeall (-alerts) All event types except alertsAlarms Alarms onlyAlerts Alerts onlyop/CL Open/close onlyDisable report No events reporting

Note: “All” means that all 3 groups are reported and also trouble messages:

sensor / system low battery, sensor inactivity, power failure, jamming, communication failure etc.

Page 58: VISONIC 2008 - vihdinhalytinpalvelu.fivihdinhalytinpalvelu.fi/pdf/2008_Powermax_Pro_Technical_Training.pdf · Visonic Group, Nordic Region. Powermax Pro ArchitectureSystem Architecture..Control

Remote Control by SMS

SMS Command List

Command SMS FormatArm AWAY “AWAY <code>” or “AW <code>”Arm AWAY instant “AWAY INST <code>” or “AWI <code>”Arm AWAY Latchkey “LATCHKEY <code>” or “LK <code>”Arm AWAY Latchkey instant “LATCHKEY INST <code>” or “LKI <code>”Arm HOME “HOME <code>” or “HM <code>”Arm HOME instant “HOME INST <code>” or “HMI <code>”Disarm “DISARM <code>” or “DA <code>”Turn light xx on (xx = 01 – 15) “LIGHT xx ON <code>” or “LT xx ON <code>”Turn light xx off (xx = 01 – 15) “LIGHT xx OFF <code>” or “LT xx OFF <code>”Turn PGM on “PGM ON <code>”Turn PGM off “PGM OFF <code>”Define custom house identity “HOUSE NAME <code> <house ID>” or “HN <code> <house ID>”Query system status “STATUS <code>” or “ST <code>”Example of SMS reporting to GSM Phone: JOHN’S HOME

**DISARM**

JOHN’S HOUSEPOWERMAX: LOW BATTERYGARAGE: LOW BATTERY