vicinity map title sheet indiana usgs 7.5' quadrangle ... · specified lighting systems 8904...
TRANSCRIPT
C1.0 (TITLE SHEET)Sheet No. :
Project Number:
Bordenet Civil Engineering &Land Surveying, LLCPh. 317-536-6181Fax: 317-536-62208902 Alibeck Ct.Indianapolis, IN 46256
2016-153
Dr. Justin Gilmore14643 North Gray Rd.Westfield, Indiana 46062
Owner: Site Engineer:
Bordenet Civil Engineering &Land Surveying, [email protected]. 317-536-61818902 Alibeck Ct.Indianapolis, IN 46256
Regulatory Agency:
City of Westfield Economic &Community DevelopmentPh. 317-804-3170Fax 317-804-31812728 E. 171st StreetWestfield, Indiana 46074
REVISION BLOCK
Owner:
Plan Date: June 16th, 2016
Site Engineer:
Regulatory Agency:
Bordenet Civil Engineering &Land Surveying, [email protected]. 317-536-61818902 Alibeck Ct.Indianapolis, IN 46256
City of Westfield Economic &Community DevelopmentPh. 317-804-3170Fax 317-804-31812728 E. 171st StreetWestfield, Indiana 46074
Dr. Justin Gilmore14643 North Gray Rd.Westfield, Indiana 46062
PROJECT NARRATIVE
IDEM SANITARY MAIN EXTENSIONIDEM WATER MAIN EXTENSION
LOCAL PLANNING
ELECTRIC UTILITYGAS UTILITY
WATER UTILITYSANITARY UTILITY
TELEPHONE UTILITYCABLE UTILITY
IDEM RULE 5 NOI
LAND DESCRIPTION
INDIANA UNDERGROUND
PLANTPROTECTION SERVICE
1-800-382-5544
TITLE SHEET
1" = 2000'
DescriptionSheet Number
Title SheetC1.0
C2.0
C2.1
Site Plan
C2.2
INDIANA USGS 7.5' QUADRANGLE LOCATION MAP CONTACT INFORMATION INDEX
C3.0
Construction Specifications
Erosion Control Details
Grading Plan
C4.0
PENDING
PLAN STATUS
NOT APPLICABLENOT APPLICABLENOT APPLICABLECOORDINATE WITH UTILITY PROVIDERCOORDINATE WITH UTILITY PROVIDERCOORDINATE WITH UTILITY PROVIDERCOORDINATE WITH CITIZENSCOORDINATE WITH CITIZENS
VICINITY MAP
Erosion Control Plan
C3.1 Site Details
NOT APPLICABLE
Police 317-804-3200
17535 Dartown Road
Westfield, Indiana 46074
Fire Garry Harling
317-804-3307
17535 Dartown Road
Westfield, Indiana 46074
Westfield Public Works Jeremy Lollar / Phil Sundling
317-804-3100
2706 E. 171st Street
Westfield, Indiana 46074
Westfield Pre-Construction John Rankin
317-804-3147
2706 E. 171st Street
Westfield, Indiana 46074
Westfield Stormwater Mike Morgan / Wes Rood
317-804-3100
2706 E. 171st Street
Westfield, Indiana 46074
Water & Sewer Citizens Westfield
Jeff Miller
317-263-6442
2150 Dr. Martin Luther King Drive
Indianapolis, Indiana 46202
Gas Vectren
Resa Glover / Chad Miller
317-776-5550
P.O. Box 1700
Noblesville, Indiana 46061
Electric Duke Energy
Bill Oldham
317-776-5331
100 South Mill Creek Road
Noblesville, Indiana 46062
Data/Telecom AT&T
Steve Krebs
317-252-42755858 North College Avenue
Indianapolis, Indiana 46220
C3.2 Sewer Details
C2.0 (SITE PLAN)Sheet No. :
Project Number:
Bordenet Civil Engineering &Land Surveying, LLCPh. 317-536-6181Fax: 317-536-62208902 Alibeck Ct.Indianapolis, IN 46256
2016-153
Owner:
Plan Date: June 16th, 2016
Site Engineer:
Regulatory Agency:
Bordenet Civil Engineering &Land Surveying, [email protected]. 317-536-61818902 Alibeck Ct.Indianapolis, IN 46256
City of Westfield Economic &Community DevelopmentPh. 317-804-3170Fax 317-804-31812728 E. 171st StreetWestfield, Indiana 46074
Dr. Justin Gilmore14643 North Gray Rd.Westfield, Indiana 46062
REVISION BLOCK
GENERAL NOTES
PLAN NOTES
SITE PLAN
C2.1 (GRADING PLAN)Sheet No. :
Project Number:
Bordenet Civil Engineering &Land Surveying, LLCPh. 317-536-6181Fax: 317-536-62208902 Alibeck Ct.Indianapolis, IN 46256
2016-153
Owner:
Plan Date: June 16th, 2016
Site Engineer:
Regulatory Agency:
Bordenet Civil Engineering &Land Surveying, [email protected]. 317-536-61818902 Alibeck Ct.Indianapolis, IN 46256
City of Westfield Economic &Community DevelopmentPh. 317-804-3170Fax 317-804-31812728 E. 171st StreetWestfield, Indiana 46074
Dr. Justin Gilmore14643 North Gray Rd.Westfield, Indiana 46062
REVISION BLOCK
GENERAL NOTES
PLAN NOTES
GRADING PLAN
INDIANA UNDERGROUND
PLANTPROTECTION SERVICE
1-800-382-5544
C2.2 (EROSION PLAN)Sheet No. :
Project Number:
Bordenet Civil Engineering &Land Surveying, LLCPh. 317-536-6181Fax: 317-536-62208902 Alibeck Ct.Indianapolis, IN 46256
2016-153
Owner:
Plan Date: June 16th, 2016
Site Engineer:
Regulatory Agency:
Bordenet Civil Engineering &Land Surveying, [email protected]. 317-536-61818902 Alibeck Ct.Indianapolis, IN 46256
City of Westfield Economic &Community DevelopmentPh. 317-804-3170Fax 317-804-31812728 E. 171st StreetWestfield, Indiana 46074
Dr. Justin Gilmore14643 North Gray Rd.Westfield, Indiana 46062
REVISION BLOCK
INDIANA UNDERGROUND
PLANTPROTECTION SERVICE
1-800-382-5544
GENERAL NOTES
PLAN NOTES
EROSION PLAN
SOILS MAP
Owner:
Plan Date: June 16th, 2016
Site Engineer:
Regulatory Agency:
Bordenet Civil Engineering &Land Surveying, [email protected]. 317-536-61818902 Alibeck Ct.Indianapolis, IN 46256
City of Westfield Economic &Community DevelopmentPh. 317-804-3170Fax 317-804-31812728 E. 171st StreetWestfield, Indiana 46074
Dr. Justin Gilmore14643 North Gray Rd.Westfield, Indiana 46062
C3.0 (EROSION DETAILS)Sheet No. :
Project Number:
Bordenet Civil Engineering &Land Surveying, LLCPh. 317-536-6181Fax: 317-536-62208902 Alibeck Ct.Indianapolis, IN 46256
2016-153
REVISION BLOCK
GENERAL NOTES
PERMANENT SEEDING DETAILS (PS)
SEEDING SCHEDULE
Owner:
Plan Date: June 16th, 2016
Site Engineer:
Regulatory Agency:
Bordenet Civil Engineering &Land Surveying, [email protected]. 317-536-61818902 Alibeck Ct.Indianapolis, IN 46256
City of Westfield Economic &Community DevelopmentPh. 317-804-3170Fax 317-804-31812728 E. 171st StreetWestfield, Indiana 46074
Dr. Justin Gilmore14643 North Gray Rd.Westfield, Indiana 46062
C3.1 (SITE DETAILS)Sheet No. :
Project Number:
Bordenet Civil Engineering &Land Surveying, LLCPh. 317-536-6181Fax: 317-536-62208902 Alibeck Ct.Indianapolis, IN 46256
2016-153
REVISION BLOCK
GENERAL NOTES
SITE DETAILS
110 #/SYD HMA SURFACE
330 #/SYD HMA BINDER
EXISTING GROUND
STANDARD DUTY ASPHALTPAVING SECTION (SA)
6" NO. 53 COMPACTED AGGREGATE
MONOLITHIC WALK AND CURB (MWC)
NOT TO SCALEBUILDING RAMP DETAILS (RD)
INDOT SIDEWALK RAMP DETAILS (INDOT)
REVISION BLOCK
C3.2 (SEWER DETAILS)Sheet No. :
Project Number:
Bordenet Civil Engineering &Land Surveying, LLCPh. 317-536-6181Fax: 317-536-62208902 Alibeck Ct.Indianapolis, IN 46256
2016-153
Owner:
Plan Date: June 16th, 2016
Site Engineer:
Regulatory Agency:
Bordenet Civil Engineering &Land Surveying, [email protected]. 317-536-61818902 Alibeck Ct.Indianapolis, IN 46256
City of Westfield Economic &Community DevelopmentPh. 317-804-3170Fax 317-804-31812728 E. 171st StreetWestfield, Indiana 46074
Dr. Justin Gilmore14643 North Gray Rd.Westfield, Indiana 46062
**
GENERAL NOTES
SEWER DETAILS
REVISION BLOCK
C4.0 (SPECIFICATIONS)Sheet No. :
Project Number:
Bordenet Civil Engineering &Land Surveying, LLCPh. 317-536-6181Fax: 317-536-62208902 Alibeck Ct.Indianapolis, IN 46256
2016-153
Owner:
Plan Date: June 16th, 2016
Site Engineer:
Regulatory Agency:
Bordenet Civil Engineering &Land Surveying, [email protected]. 317-536-61818902 Alibeck Ct.Indianapolis, IN 46256
City of Westfield Economic &Community DevelopmentPh. 317-804-3170Fax 317-804-31812728 E. 171st StreetWestfield, Indiana 46074
Dr. Justin Gilmore14643 North Gray Rd.Westfield, Indiana 46062
GENERAL NOTES
SPECIFICATIONS
STORM SEWERAll storm sewer construction shall comply with with the City ofWestfield technical standards.
SANITARY SEWERAll sanitary sewer construction shall comply with with the Cityof Westfield technical standards.
UTILITY CONNECTIONSAll utility construction shall comply with with the standards ofthe utility provider.
#Date
Comments
Drawn By:
Checked By:
Scale:
Revisions
Page M of 1
Date:7/7/2016
- - - - - -(P) 317-577-8100(F) 317-577-8101
CITY
, STA
TE Z
IP C
ODE
SPEC
IFIE
D LI
GHTI
NG
SYST
EMS
8904
BAS
H ST
, SUI
TE B
INDI
ANAP
OLIS
, IN
462
56
NOTES:(1) Layouts are produced using AGi32 software. Technicians have been trained and certified by Light Analysts- Littleton, Colorado.(2) It is understood that specification, performance and distribution vary widely among products. The indicated photometric values are for products listed on this document. Any variance during installation or product could cause light levels to shift.(3) Photometric information and IES files are provided by individual manufacturers. Specified Lighting utilizes standard practices to input these manufacturer provided files into AGI software.(4) Specified Lighting takes no responsibility in the verification of pre-existing conditions. We will use input values to best represent field conditions. However, due to construction methods, design changes and/ or finish options reflectance valuescan be altered. It should be understood that these properties can effect the final outcome of light levels.(5) This layout was produced using documents and information provided by others. Specified Lighting takes no responsibility in deeming this information reliable.(6) SLS is not responsible for field verification or input of environmental criteria on designs that require open or exposed ceiling decks. Photometric studies may be skewed due to unknown ceiling conditions, HVAC components and sturctural elements.Final light levels can not be guaranteed under these parameters.
DR G
ILM
ORE
20'
DU&SE
5'
BL
ACCESS ESMT.
SIGNESMT. SIGN ESMT.
DU&SE
DU&SE
DU&SE
DU&SE
30'BL
WATER
ESMT
5'BL
20'
DU&SE
ACCESSESMT.
30'
BL
DU&SE
DU&SE
WATERESMT
WATERESMT
WATERESMT
RADRICK DRIVE
GRAY
ROAD
MARKET
CENTER
DRIVE
N 89°59'25" E 278.02'
S 00°56'54" E
231.71'
S 00°46'11" E 230.11'
MH: 10 MH: 10 MH: 10 MH: 10
MH: 10MH: 10 MH: 10 MH: 10 MH: 10 MH: 10 MH: 10MH: 10 MH: 10MH: 10
MH: 20
MH: 20MH: 20 MH: 20
0.2
0.80.70.60.50.60.70.70.5 0.7 0.10.80.7 0.8
0.6
0.4
0.3
0.6
0.20.5 0.30.90.8 0.70.60.50.60.70.8 0.7
0.2
0.4 0.90.90.90.90.9 0.6
0.4
0.6
2.3
0.70.70.70.40.7
0.6 0.6 0.30.50.80.80.80.90.7 0.6 0.20.70.90.90.90.90.8 0.8
0.3
0.60.3
0.30.50.4
1.0
0.6
0.3
0.50.70.70.6
0.3
3.0
0.6
0.6
0.3
0.9
0.50.8
0.20.4
0.4
0.6
0.5
0.30.40.40.60.7
0.2
0.6
0.9 0.51.01.41.71.4
0.6
0.8
0.6
1.00.91.01.31.71.6 1.0
1.8 0.82.74.45.64.11.5
0.3
2.00.8 3.85.25.23.30.4
1.1
3.1
0.60.7 0.80.60.70.7 0.40.7 0.20.80.90.70.70.8
0.9
0.9
1.0 0.91.00.70.80.8
0.7
0.8
0.6
0.81.00.70.80.70.7 0.8
0.8
0.9
0.80.6
0.8
0.4 0.80.7 0.70.80.8
0.40.50.50.5
0.7
0.8
0.80.90.70.70.7
0.8 0.60.5 0.80.80.60.50.40.5
0.8
1.00.8 0.30.50.80.7
0.7
0.8
0.9
0.91.00.80.80.70.8 0.6
0.9
0.5
0.8
0.80.90.80.3 0.9 0.70.80.90.90.50.70.7 0.8
0.8 0.81.01.01.00.8 0.80.7
0.5 0.30.8
1.0
0.7
0.40.7
0.5
0.8 0.6
0.6
0.5
1.00.8 0.9
0.60.80.70.7 0.71.01.0 0.70.8 1.0
3.0
0.2
0.2
0.2 5.0 4.45.5 5.6
0.3
5.3
0.2
5.2
0.2
0.2
0.2
0.2
0.3
0.2
0.3
0.3
0.3
0.1
0.1 0.6
0.20.4
0.3
3.6
4.3
1.0
2.00.90.50.71.63.13.62.51.22.8 1.50.1 2.81.30.71.02.23.63.51.80.70.30.1 0.5
5.9 1.6 5.22.72.35.55.55.64.32.51.72.7 7.26.2 9.37.510.28.16.55.43.21.40.60.40.3
3.6
5.1
7.2 4.37.28.712.010.26.66.75.95.74.43.1
6.7
8.7 2.86.40.3
0.10.20.51.22.94.96.17.810.1
4.4
Luminaire Schedule Calculation SummaryLabel CalcType Units Avg Max MinSymbol Qty Label Arrangement Total Lamp Lumens LLF Avg/Min Max/MinObject_1_Planar Illuminance Fc 0.85 5.6 0.1 8.5014 XTOR2A SINGLE N.A. 0.864 56.00
1 GAT-080-LED-E1-3-SPUN-X SINGLE N.A. 0.9123 GAT-080-LED-E1-5-SPUN-X_1 SINGLE N.A. 0.912
Object_3_Top Illuminance Fc 3.26 12.0 0.1 32.60 120.00
XTOR CROSSTOUR LED
APPLICATIONS:
WALL / SURFACEPOST / BOLLARD
LOW LEVELFLOODLIGHT
INVERTEDSITE LIGHTING
Lumark
SPECIFICATION FEATURES
ConstructionSlim, low-profile LED design with rugged one-piece, die-cast aluminum hinged removable door and back box. Matching housing styles incorporate both a small and large design. The small housing is available in 7W and 18W. The large housing is available in the 26W model. Patent pending secure lock hinge feature allows for safe and easy tool-less electrical connections with the supplied push-in connectors. Back box includes three (3) half-inch, NPT threaded conduit entry points. The universal back box supports both the small and large forms and mounts to standard 3-1/2” to 4” round and octagonal, 4” square, single gang and masonry junction boxes. Key hole gasket allows for adaptation to junction box or wall. External fin design extracts heat from the fixture surface. One-piece silicone gasket seals door and back box. Minimum 5” wide pole for site lighting application. Not recommended for car wash applications.
OpticalSilicone sealed optical LED chamber incorporates a custom engineered mirrored anodized reflector providing high-efficiency illumination. Optical assembly includes impact-resistant tempered glass and meets IESNA requirements for full cutoff compliance. Solid state LED Crosstour luminaries are thermally optimized with five (5) lumen packages in cool 5000K or neutral warm 3500K LED color temperature (CCT).
ElectricalLED driver is mounted to the die-cast housing for optimal heat sinking. LED thermal management system incorporates both conduction and natural convection to transfer heat rapidly away from the LED source. 7W models operate in -40°C to 40°C [-40°F to 104°F]. 18W and 26W models operate in -40°C to 40°C [-40°F to 104°F]. High ambient 50°C models available. Crosstour luminaires maintain greater than 90% of initial
light output after 72,000 hours of operation. Three (3) half-inch NPT threaded conduit entry points allow for thru-branch wiring. Back box is an authorized electrical wiring compartment. Integral LED electronic driver incorporates surge protection. 120-277V 50/60Hz or 347V 60Hz models.
FinishCrosstour is protected with a Super durable TGIC carbon bronze or summit white polyester powder coat paint. Super durable TGIC powder coat paint finishes withstand extreme climate conditions while providing optimal color and gloss retention of the installed life.
WarrantyFive-year warranty.
TD514013EN2015-05-29 11:34:51
The patented Lumark Crosstour™ LED Wall Pack Series of luminaries provides an architectural style with super bright, energy efficient LEDs. The low-profile, rugged die-cast aluminum construction, universal back box, stainless steel hardware along with a sealed and gasketed optical compartment make the Crosstour impervious to contaminants. The Crosstour wall luminaire is ideal for wall/surface, inverted mount for façade/canopy illumination, post/bollard, site lighting, floodlight and low level pathway illumination including stairs. Typical applications include building entrances, multi-use facilities, apartment buildings, institutions, schools, stairways and loading docks test.
DESCRIPTION
Catalog # Type
Date
Project
Comments
Prepared by
7W & 18W5-3/4" [146mm]
26W6-5/8" [168mm]
7W & 18W6-3/4" [171mm]
26W8" [203mm]
7W & 18W3-5/8" [92mm]
26W4" [102mm]
DIMENSIONS
C E R T I F I C A T I O N D A T AUL/cUL Wet Location ListedLM79 / LM80 CompliantROHS CompliantADA CompliantNOM Compliant ModelsIP66 Ingressed Protection RatedTitle 24 CompliantDesignLights Consortium® Qualified*
T E C H N I C A L D A T A40°C Maximum Ambient TemperatureExternal Supply Wiring 90°C Minimum
E P AEffective Projected Area (Sq. Ft.):XTOR1A/XT0R2A=0.34XTOR3A=0.45
S H I P P I N G D A T A :Approximate Net Weight:3.7 – 5.25 lbs. [1.7 – 2.4 kgs.]
*www.designlights.org
10" [254mm]
17-1/2" [445mm]
10"[254mm]
17-1/2"[445mm]
ESCUTCHEON PLATES
Specifications and dimensions subject to change without notice.
Eaton 1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.eaton.com/lighting
Ambient Temperature
TM-21 LumenMaintenance
(72,000 Hours)
Theoretical L70(Hours)
XTOR1A Model
25°C > 92% > 290,000
40°C > 92% > 290,000
50°C > 91% > 270,000
XTOR2A Model
25°C > 91% > 270,000
40°C > 90% > 260,000
50°C > 88% > 225,000
XTOR3A Model
25°C > 91% > 280,000
40°C > 91% > 270,000
50°C > 89% > 240,000
LUMEN MAINTENANCE
LED Information XTOR1A XTOR2A XTOR2A-N XTOR3A XTOR3A-N
Delivered Lumens(Wall Mount)
722 1,633 1,523 2,804 2,284
Delivered Lumens(With FloodAccessory Kit) 1
468 1,060 978 2,168 1,738
B.U.G. Rating 2 B0-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0 B1-U0-G0
CCT (Kelvin)
5,000 5,000 3,500 5,000 3,500
CRI (Color Rendering Index)
65 65 70 65 70
Power Consumption (Watts)
7W 18W 18W 26W 26W
NOTES: 1 Includes shield and visor. 2 B.U.G. Rating does not apply to fl oodlighting.
LUMENS - CRI/CCT TABLE
7W Series 18W Series 26W Series
XTOR1A=7W, 5000K, Carbon Bronze XTOR2A=18W, 5000K, Carbon Bronze XTOR3A=26W, 5000K, Carbon Bronze
XTOR1A-WT=7W, 5000K, Summit White XTOR2A-N=18W, 3500K, Carbon Bronze XTOR3A-N=26W, 3500K, Carbon Bronze
XTOR1A-PC1=7W, 5000K, 120V PC, Carbon Bronze XTOR2A-WT=18W, Summit White XTOR3A-WT=26W, Summit White
XTOR2A-PC1=18W, 120V PC, Carbon Bronze XTOR3A-PC1=26W, 120V PC, Carbon Bronze
STOCK ORDERING INFORMATION
7W Series 18W Series 26W Series
XTOR1A-WT-PC1=7W, 5000K, Summit White, 120V PC XTOR2A-PC2=18W, 5000K, 208-277V PC, Carbon Bronze XTOR3A-PC2=26W, 5000K, 208-277V PC, Carbon Bronze
XTOR2A-WT-PC1=18W, 5000K, Summit White, 120V PC XTOR3A-WT-PC1=26W, 5000K, Summit White, 120V PC
XTOR2A-WT-PC2=18W, 5000K, Summit White, 208-277V PC XTOR3A-WT-PC2=26W, 5000K, Summit White, 208-277V PC
XTOR2A-N-WT=18W, 3500K, Summit White XTOR3A-N-WT=26W, 3500K, Summit White
XTOR2A-N-PC1=18W, 3500K, 120V PC, Carbon Bronze XTOR3A-N-PC1=26W, 3500K, 120V PC, Carbon Bronze
XTOR2A-N-PC2=18W, 3500K, 208-277V PC, Carbon Bronze XTOR3A-N-PC2=26W, 3500K, 208-277V PC, Carbon Bronze
XTOR2A-N-WHT-PC1=18W, 3500K, Summit White, 120V PC XTOR3A-N-WHT-PC1=26W, 3500K, Summit White, 120V PC
XTOR2A-N-WT-PC2=18W, 3500K, Summit White, 208-277V PC XTOR3A-N-WT-PC2=26W, 3500K, Summit White, 208-277V PC
5-DAY QUICK SHIP ORDERING INFORMATION
VoltageModel Series
XTOR1A XTOR2A XTOR3A
120V 0.05A 0.15A 0.22A
208V 0.03A 0.08A 0.13A
240V 0.03A 0.07A 0.11A
277V 0.03A 0.06A 0.10A
347V 0.025A 0.058A 0.082A
CURRENT DRAW
XTOR CROSSTOUR LED
TD514013EN2015-05-29 11:34:51
Sample Number: XTOR2A-N-WT-PC1
Series 1 LED Kelvin Color Housing Color Options (Add as Suffi x) Accessories (Order Separately)
XTOR1A=Small Door, 7WXTOR2A=Small Door, 18WXTOR3A=Small Door, 26W
[Blank]= Bright White (Standard) 5000K
N= Neutral Warm White, 3500K 2
[Blank]= Carbon Bronze(Standard)
WT=Summit White
PC1=Photocontrol 120V 3
PC2=Photocontrol 208-277V 3, 4
347V=347V 5
HA=50ºC High Ambient 5
WG/XTOR=Wire Guard 6
XTORFLD-KNC=Knuckle Floodlight Kit 7
XTORFLD-TRN=Trunnion Floodlight Kit 7
XTORFLD-KNC-WT=Knuckle Floodlight Kit, Summit White 7
XTORFLD-TRN-WT=Trunnion Floodlight Kit, Summit White 7
EWP/XTOR= Escutcheon Wall Plate, Carbon BronzeEWP/XTOR-WT= Escutcheon Wall Plate, Summit White
NOTES: 1 DesignLights Consortium® Qualifi ed. Refer to www.designlights.org Qualifi ed Products List under Family Models for details. 2 XTOR1A not available in 3500K. 3 Photocontrols are factory installed. 4 Order PC2 for 347V models. 5 Thru-branch wiring not available with HA option or with 347V. 6 Wire guard for wall/surface mount. Not for use with fl oodlight kit accessory. 7 Floodlight kit accessory supplied with knuckle (KNC) or trunnion (TRN) base, small and large top visors and small and large impact shields.
ORDERING INFORMATION
GAT GENERATION
SERIES AVENUE LED
LED
DECORATIVE POST TOP
LUMINAIRE
McGraw-Edison
SPECIFICATION FEATURES
ConstructionHOUSING: Heavy-duty cast aluminum housing and removable door. A single quarter turn fastener on the removable door provides tool-less access to wiring compartment. CAGE ASSEMBLY Cage assembly manufactured of heavy-duty cast aluminum and mounted to the exterior of the base housing via four stainless steel fasteners. Finished to match housing. TOPS AND FINIALS: Avenue top is heavy-duty spun aluminum offering top access for tool-less entrance into the source compartment during maintenance. Choose from four cast aluminum finials for customized fixture style. TWISTLOCK GLOBE: The optional twistlock assembly offers ease of maintenance through instant access to both the LED and wiring compartment by twisting the top refractor assembly and lifting it from the mating lock plate
OpticalREFRACTIVE GLOBE: High efficiency refractive optical systems are precisely designed utilizing a combination of refractive and reflective prisms. Available in Type III or Type V distributions. Lighting grade acrylic ensures long lasting optical clarity and resistance to discoloration.
Electrical120-277V 50/60Hz operation. 10kV /10kA common- and differential mode surge protection standard. Thermal management transfers heat rapidly away from the LED source for optimal efficiency and light output. Ambient operating temperature from -40°C to 40°C. Standard three-position tunnel type compression terminal block.
MountingBase casting slipfits over a standard 3” O.D. tenon and secured via four stainless steel allen head fasteners. 3G vibration tested.
FinishCast and spun components finished in a five-stage premium TGIC polyester powder coat paint, 2.5 mil nominal thickness for superior protection against fade and wear. Consult the McGraw-Edison Architectural Color brochure for a complete selection of standard colors including black, bronze, grey, white, dark platinum, graphite metallic and hartford green. RAL and custom color matches available.
WarrantyFive-year warranty.
TD516023EN2016-02-16 08:51:07
The GAT Generation Series Avenue LED provides an updated styling and smooth exterior appearance, making it the perfect choice to add a contemporary feel to any setting. Its superior photometrics offer excellent illumination and uniformity for many of today’s applications. Its styling blends well in many settings – historic districts, downtown streetscapes, roadways, residential neighborhoods, as well as city parks and educational campuses. The Generation Series LED sets a new standard for decorative post top luminaires..
DESCRIPTION
E P AEffective Projected Area: (Sq. Ft.)2.1
S H I P P I N G D A T AApproximate Net Weight:50 lbs. (23 kgs.)
S
YSTEMS
C
E R T I F I E
D
37-3/8"[949mm]
25-3/8" [645mm]
DIMENSIONS
Catalog # Type
Date
Project
Comments
Prepared by
Specifications and dimensions subject to change without notice.
Eaton 1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.eaton.com/lighting
Distribution
Correlated Color
Temperature (CCT)
CageTotal
Lumens(Estimated)
LuminaireWattage(Nominal)
Type III 4000K Avenue 5,200 99W
Type III 4000K None 8,000 99W
Type V 4000K Avenue 5,500 99W
Type V 4000K None 8,500 99W
POWER AND LUMENS
AmbientTemperature
TM-21 Lumen Maintenance (36,000 Hours)
Theoretical L70(Hours)
15°C >93% 240,000
25°C >92% 210,000
40°C >89% 117,000
LUMEN MAINTENANCE
Architectural Modern Victorian Nostalgic
FINIALS
GAT GENERATION SERIES AVENUE LED
Sample Number: GAT-080-LED-E1-3-UUA-BK
Product Family 1 LED Series Lamp Type Voltage Refractor Type Top Type 2 Cage Type 2 Finial Type 2 Color 3
GAT=Architectural Base 080= 080 Series LED= Solid State Light Emitting Diodes
E1=Electronic (120-277V)
3=Type III5=Type V
U=Avenue C=ClassicalU=AvenueX=None
A=ArchitecturalM=ModernN=NostalgicV=VictorianX=None
AP=GreyBZ=BronzeBK=BlackGN=Hartford GreenWH=WhiteDP=Dark PlatinumGM=Graphite Metallic
Options (Add as Suffi x) Accessories (Order Separately)
P=Polycarbonate RefractorR= NEMA Twistlock Photocontrol ReceptacleD=Downlight Refl ectorHA=50°C High Ambient Temperature Rating2L=Two Circuits SH=Street Side/House Side Switching Capable
MA1252=10kV Circuit Module ReplacementGLR-080-E1=080 Series LED Replacement Module with 120-277V Universal DriverGLR-080-E1-2L=080 Series LED Replacement Module with 120-277V Universal Driver and Bi-Level Switching Capable GLR-080-E1-SH=080 Series LED Replacement Module with 120-277V Universal Driver and Street Side/House Side Switching Capable
NOTES:1. Customer is responsible for engineering analysis to confi rm pole and fi xture compatibility for all applications. Refer to our white paper WP513001EN for additional support information. 2. Painted to match base. 3. Other fi nish colors available, including a full line of RAL color matches. Consult your lighting representative at Eaton for more information.
ORDERING INFORMATION
TD516023EN2016-02-16 08:51:07
Narrative Statement Radrick Professional Building
This project is a ten thousand square foot (10,000 s.f.) professional office building to be constructed on a 1.47 acre parcel on the northwest corner of Radrick Drive and Gray Road. The parcel is located approximately one quarter mile north of a major intersection at 146th Street and Gray Road. It is within the Bridgewater Planned Unit Development. It is the intention of the owner to comply with all of the requirements set forth in the PUD including building use, construction and landscaping. The structure will be one story, built of standard wood framing construction with a wood trussed, sloping roof. It will be a rectangular shape, roughly one hundred sixty feet long and sixty two feet deep. (160’x 62’) The exterior will be all masonry, a combination of mostly red brick with stone accents around some of the building offsets. The roof will be a commercial grade asphalt type shingle. This type of construction will compliment the surrounding residential apartment construction and low-rise commercial areas. With technically three front yard areas, an abundance of landscaping is required and will be provided to enhance the streetscape and buffer the parking areas. A landscape buffer yard is required to the adjacent apartment structures which will be built to the north.