vfa6 u (assembly)
DESCRIPTION
VFA6 U (Assembly)TRANSCRIPT
-
DETAIL ADETAIL B
DETAIL C DETAIL D
DETAIL E
DETAIL F
PARTS LIST
NET WT.UNIT WT.LENGTHPART DESCRIPTIONPART NO.QTYITEM
8.738.73 UPPER MOUNTING BRACKET FOR V-FRAMEX-19204311
8.738.73 LOWER MOUNTING BRACKET FOR V-FRAMEX-19204412
11.465.73 BACKING PLATEX-15999923
86.9643.48 SUPPORT ARM, BC-FRAMEX-19754424
46.1323.07722-3/8" X 72" SCH 40 GALVANIZED PIPEP27225
4.972.48 FLAT DISK CLAMP PLATE 4" CENTERS (GALVANIZED)X-12759426
3.650.91 CLAMP (S) (4" V-CLAMP) GALVANIZEDX-10006447
14.833.71 CROSSOVER PLATE 2-3/8" X 2-3/8"SCX148
25.1225.12 1 1/4" X 126" SCH 40 PIPE (STIFF ARM)P112619
4.090.41 1/2'' x 6-1/2" HDG HEX BOLT GR5 FULL THREADG120651010
1.620.27 1/2'' x 4" HDG HEX BOLT GR5 FULL THREADG1204611
0.410.20 1/2'' x 2-1/2" HDG HEX BOLT GR5G12212212
13.130.66 1/2" X 2-1/2" X 4-1/2" X 2" GALV. U-BOLTX-UB12122013
2.040.03 1/2" HDG USS FLATWASHERG12FW6014
0.810.01 1/2" HDG LOCKWASHERG12LW5815
4.150.07 1/2'' HDG HEAVY 2H HEX NUTG12NUT5816
1.070.54 3/4''-10 X 2-3/4" A325 BOLT WITH 1-3/8" THREADA34234217
0.090.04 3/4" HDG LOCKWASHERG34LW218
0.430.21 3/4'' HDG HEAVY 2H HEX NUTG34NUT219
A
BC
D
E
F
DESCRIPTION
DRAWING USAGE CHECKED BY
ENG. APPROVALDRAWN BY
DWG. NO.
CPD NO.
CEK
1 O
F 2
BMC 11/16/2012
5/2/2011 VFA6-U
6'V-FRAME ASSEMBLY
W/ STIFF ARM
CUSTOMER VFA6-UCLASS SUB
PART NO.
PA
GE
TOLERANCES ON DIMENSIONS, UNLESS OTHERWISE NOTED ARE:SAWED, SHEARED AND GAS CUT EDGES ( 0.030")DRILLED AND GAS CUT HOLES ( 0.030") - NO CONING OF HOLESLASER CUT EDGES AND HOLES ( 0.010") - NO CONING OF HOLESBENDS ARE 1/2 DEGREEALL OTHER MACHINING ( 0.030")ALL OTHER ASSEMBLY ( 0.060")
TOLERANCE NOTES
PROPRIETARY NOTE:THE DATA AND TECHNIQUES CONTAINED IN THIS DRAWING ARE PROPRIETARY INFORMATION OF VALMONTINDUSTRIES AND CONSIDERED A TRADE SECRET. ANY USE OR DISCLOSURE WITHOUT THE CONSENT OFVALMONT INDUSTRIES IS STRICTLY PROHIBITED.
Engineering Support Team:
1-888-753-7446
valmont
Locations:New York, NYAtlanta, GALos Angeles, CAPlymouth, INSalem, ORDallas, TX
16151411
7
67
10 14 15 16
11 14 15 16
7
7 6
11 14 15 16
191817
16151412
1
3
10 14 15 16
16151412
191817
210 14 15 16
3
13 14 15 16
161514138
16151413
2-3/8" O.D. ANTENNA MOUNTING PIPE (LENGTH VARIES)MUST BE CENTERED VERTICALLY ON V-FRAME.
PIPES MUST BE EQUALLY DISTRIBUTED ACROSS THEFACE OF THE V-FRAME (SEE PAGE 2)
(SHOWN FOR REFERENCE ONLY)
SECTION LEG1-1/4" MIN. - 4-1/2" O.D. MAX.
(REFERENCE ONLY)
5
4
9
TOTAL WT. # 238.42
-
CA
LOWER
B
A
UPPER
NOTES: 1. USE HOLE "A" IN UPPER AND LOWER BRACKETS FOR STRAIGHT LEGS. 2. USE HOLE "A" IN UPPER BRACKET AND HOLE "C" IN LOWER BRACKET FOR 2' IN 20' TAPER LEGS. (3.309) 3. USE HOLE "B" IN UPPER BRACKET AND HOLE "C" IN LOWER BRACKET FOR 6" IN 20' TAPER LEGS. (0.827)
DESCRIPTION
DRAWING USAGE CHECKED BY
ENG. APPROVALDRAWN BY
DWG. NO.
CPD NO.
CEK
2 O
F 2
BMC 11/16/2012
5/2/2011 VFA6-U
6'V-FRAME ASSEMBLY
W/ STIFF ARM
CUSTOMER VFA6-UCLASS SUB
PART NO.
PA
GE
TOLERANCES ON DIMENSIONS, UNLESS OTHERWISE NOTED ARE:SAWED, SHEARED AND GAS CUT EDGES ( 0.030")DRILLED AND GAS CUT HOLES ( 0.030") - NO CONING OF HOLESLASER CUT EDGES AND HOLES ( 0.010") - NO CONING OF HOLESBENDS ARE 1/2 DEGREEALL OTHER MACHINING ( 0.030")ALL OTHER ASSEMBLY ( 0.060")
TOLERANCE NOTES
PROPRIETARY NOTE:THE DATA AND TECHNIQUES CONTAINED IN THIS DRAWING ARE PROPRIETARY INFORMATION OF VALMONTINDUSTRIES AND CONSIDERED A TRADE SECRET. ANY USE OR DISCLOSURE WITHOUT THE CONSENT OFVALMONT INDUSTRIES IS STRICTLY PROHIBITED.
Engineering Support Team:
1-888-753-7446
valmont
Locations:New York, NYAtlanta, GALos Angeles, CAPlymouth, INSalem, ORDallas, TX
30 1/16" 30 1/16"
FRAME WIDTH/2( 3")
FRAME WIDTH/2( 3")
72"
11 13/16" (REF)
31 5/8"
50"MAX. ANTENNA
PIPE SEPARATION
X
29 1/4"
X
Y
37 1/2"
A MINIMUM OF ONE TIE-BACKMUST BE USED FOR THIS
ASSEMBLY.
45(TYP.)
1 1/4"
3"
1 1/4"
3 1/8"
45MAXIMUM
(TYP.)
PIPES MUST BE SPACED EVENLYACROSS THE FACE OF THE V-FRAME (