vertical sealless h s sprayer/washer pumps a · amt vertical sealless sprayer/ washer pumps are...

2
AMT Vertical Sealless Sprayer/ Washer pumps are designed for OEM, automotive and industrial washing machines, parts cleaners, spray booths and cooling towers. “No bottom bearing” design and stainless steel impeller resists errosion from abrasives and ensures a long, maintenance free life for the pump. CNC machined stainless steel pump shafts. Built-in stainless steel suction screen protects pump from clogging and damage caused by large solids. Heavy duty universal mounting plates permit easy installation into existing tanks, booths, equipment, etc. 0 4 5 3 0 3 5 2 0 2 5 1 0 1 5 0 0 0 2 0 4 0 6 0 8 0 0 1 0 2 1 0 4 1 0 6 1 0 8 1 0 8 1 0 6 1 0 4 1 0 2 1 0 0 1 0 8 0 6 0 4 0 2 0 ) z H 0 6 ( M P R 0 5 4 3 @ y t i c a p a C 0 . 1 y t i v a r g c i f i c e p s r e t a W - d i u q i L 1 3 . 2 y b e d i v i d , i s p o t t r e v n o C ) * ( ] W k 4 2 . 2 [ P H 3 s e i r e S 4 4 4 = A ] W k 3 7 . 3 [ P H 5 s e i r e S 7 5 5 = B ] W k 9 5 . 5 [ P H 5 . 7 s e i r e S 7 5 5 = C 0 0 1 0 2 0 3 0 4 0 5 ] * . t f [ ] m [ ] m p g . S . U [ Total Head m [ 3 ] h / C B A VERTICAL SEALLESS SPRAYER/WASHER CLT-7 Vertical Sealless Sprayer/Washer Pumps Cast Iron Construction with 300 Series Investment Cast Stainless Steel Impeller Stainless Steel Pump Shaft No Bottom Bearing! Dual Volute Design Reduces Radial Load on Motor Maximum Temperature 200° F Maximum Flow 140 GPM Maximum Head 140 Ft. (61 PSI) Stainless Steel Suction Screen Includes Heavy Duty Universal Mounting Plates 3 HP to 7-1/2 HP Totally Enclosed Fan Cooled (TEFC) Motor Standard 56C or JM Shaft Motors Model 5571-95 ® A Gorman-Rupp Company 400 Spring Street Royersford, PA 19468 USA www.amtpump.com 888-amt-pump (268-7867) For use with nonflammable liquids compatible with pump component materials. Performance of Vertical Sprayer/Washer Pumps

Upload: lamtuyen

Post on 12-Aug-2018

220 views

Category:

Documents


0 download

TRANSCRIPT

AMT Vertical Sealless Sprayer/Washer pumps are designed for OEM,automotive and industrial washingmachines, parts cleaners, spray boothsand cooling towers. “No bottom bearing”design and stainless steel impellerresists errosion from abrasives andensures a long, maintenance free life forthe pump. CNC machined stainlesssteel pump shafts. Built-in stainlesssteel suction screen protects pump fromclogging and damage caused by largesolids. Heavy duty universal mountingplates permit easy installation intoexisting tanks, booths, equipment, etc.

0453035202510150

0

02

04

06

08

001

021

041

061

081

081061041021001080604020

)zH 06( MPR 0543 @ yticapaC0.1 ytivarg cificeps retaW- diuqiL 13.2 yb edivid ,isp ot trevnoC)*(

]Wk 42.2[ PH 3 seireS 444 = A]Wk 37.3[ PH 5 seireS 755 = B

]Wk 95.5[ PH 5.7 seireS 755 = C

0

01

02

03

04

05

]*.tf[ ]m[

]mpg .S.U[

To

tal H

ead

m[ 3 ]h/

C

B

AVE

RTIC

AL

SEA

LLES

S SP

RAYE

R/W

ASH

ER

CLT-7

Vertical SeallessSprayer/Washer Pumps• Cast Iron Construction with 300 SeriesInvestment Cast Stainless Steel Impeller

• Stainless Steel Pump Shaft

• No Bottom Bearing!

• Dual Volute Design Reduces Radial Load on Motor

• Maximum Temperature 200° F

• Maximum Flow 140 GPM

• Maximum Head 140 Ft. (61 PSI)

• Stainless Steel Suction Screen

• Includes Heavy Duty Universal Mounting Plates

• 3 HP to 7-1/2 HP Totally Enclosed FanCooled (TEFC) Motor

• Standard 56C or JM Shaft Motors

Model 5571-95

®

A Gorman-Rupp Company

400 Spring Street • Royersford, PA 19468 USA

www.amtpump.com • 888-amt-pump (268-7867)For use with nonflammable liquids compatible with pump component materials.

Performance of Vertical Sprayer/Washer Pumps

®

A Gorman-Rupp Company

®

A Gorman-Rupp Company

Manufacturer of AMT & IPT Pumps400 Spring Street • Royersford, PA 19468 USA

www.amtpump.com • 888-amt-pump (268-7867)The Gorman-Rupp Company reserves the right to discontinue any model or change specifications at any time without incurring any obligation.

©2012 American Machine and Tool Company. All rights reserved. 1212

CLT-8

(*) Standard NPT (Female) pipe thread.(**) This dimension may vary due to motor manufacturer's specifications.(+) 3-Phase models can also operate on 50 Hz. (This will change full load amps, service factor and RPM.)NOTE: Dimensions are in inches (millimeters) and have a tolerance of ± 1/8".NOTE: Electric supply for ALL motors must be within ±10% of nameplate voltage rating (e.g. 230V ±10%= 207 to 253).

W

10.8 [274.3]

DIS*

A

6.5 [165.1]

8.4 [213.3]

B

15.0 [381.0]

17.0 [431.8]

C

3.5 [88.9]

4.0 [101.6]

D

13.5 [342.9]

14.0 [355.6]

E

17.0 [431.8]

17.8 [452.1]

L

9.5 [241.3]

12.0 [304.8] 15.0 [381.0]

H**

29.7 [754.3]

32.0 [812.8]

Model

4445-95

4446-95

5572-95

5571-95

Curve

A

B

C

HP

3

3

5

PH

1

3

3

3

ENC

TEFC

TEFC

TEFC

TEFC

Voltage@ 60 Hz+

230

230/460

208-230/460

208-230/460

Full LoadAmps

14

8/4

14/7

18/9

Ship Wt.(Lbs.)

78

73

130

150

Standard Features• Cast Iron Construction with 300 SeriesInvestment Cast Stainless Steel Impeller

• Stainless Steel Pump Shaft

• No Bottom Bearing!

• Maximum Temperature 200° F

• Maximum Flow 140 GPM

• Maximum Head 140 ft. (61 PSI)

• Stainless Steel Suction Screen

• Includes Heavy Duty UniversalMounting Plates

• Standard 56C or JM Shaft Motors

Vertical Sealless Sprayer/Washer Pumps

Maximum Recommended Viscosity: 100 SSU

Pump Dimensional & Specification Data

Models: 4445-95 & 4446-95

Models: 5571-95 & 5572-95

Hazardous Duty/Xplosion Proof motors available from stock ranging from 1 to 10 HP (applies to 557 Series only);CALL FOR QUOTATION & LEAD TIME!