Versamax microplate reader - - Vtejte - AffordAble, tunAble microplAte reAder for 96-well formAt Versamax microplate reader Afford Able The robot-compatible VersaMax Reader is cost-effective—users never have to buy filters. Furthermore, VersaMax is reliable ...

Download Versamax microplate reader -   - Vtejte -   AffordAble, tunAble microplAte reAder for 96-well formAt Versamax microplate reader Afford Able The robot-compatible VersaMax Reader is cost-effective—users never have to buy filters. Furthermore, VersaMax is reliable ...

Post on 06-May-2018

213 views

Category:

Documents

1 download

TRANSCRIPT

<ul><li><p>An AffordAble, tunAble microplAte reAder for 96-well formAt</p><p>Versamax microplate reader</p><p>AffordAble</p><p>The robot-compatible VersaMax Reader is cost-effectiveusers never have to buy filters. Furthermore, VersaMax is reliable, which means more uptime and lower long-term cost of ownership.</p><p>wide rAnge of ApplicAtions</p><p>The VersaMax reader covers a wide range of applications: &gt; Microbial Growth/MIC &gt; IC50/LD50 &gt; Endpoint ELISAs/EIA &gt; Cytoproliferation/Cytotoxicity &gt; Colorimetric Protein &gt; Kinetic ELISAs/Enzyme Assays &gt; Bacterial Identification</p><p>powerful dAtA AnAlysis</p><p>SoftMax Pro, Software Molecular Devices industry-leading data analysis and instrument control software, is included with VersaMax </p><p>The VersaMax Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems.</p><p>tunAble, filterless flexibility</p><p>The VersaMax Reader uses a grating monochromator to select the wavelength, so the exact wavelength needed can be selected for every assay. With a wavelength range from 340 to 850 nm, this is equivalent to having 510 free filters. </p><p>exceptionAl performAnce</p><p>Using an advanced optical and electronic design, the VersaMax Reader gives the same high performance with round-bottom, flat-bottom or half-area well plates. Dual wavelength readings report the actual absorbance at each wavelength so data can be analyzed according to the users preferences. Temperature control up to 45C allows kinetic assays at ambient and physiological temperatures. </p><p>&gt; tunAble for filterless flexibility</p><p>&gt; exceptionAl performAnce</p><p>&gt; AffordAble</p><p>&gt; wide ApplicAtion bAse</p><p>&gt; powerful dAtA AnAlysis</p><p>&gt; eAsy VAlidAtion And testing</p></li><li><p>VersAmAx tunAble microplAte reAder</p><p>Temperature RegulationTemperature range: Ambient +4C to 45CTemperature uniformity (microplate): 0.5C at 37C, well-to-well</p><p>General SpecificationsDimensions (in.): 8.6 (L) x 22.8 (W) x 15 (H)Dimensions (cm): 22 (L) x 58 (W) x 38 (H)Weight: 30 lbs. (13.6 kg)Power consumption: &lt; 250 watts</p><p>Power source: 100240 Vac, 4 A 50/60 Hz</p><p>Robot compatible: Yes</p><p>ordering informAtion</p><p>Contact your Molecular Devices sales representative for configuration options.</p><p>sAles offices</p><p>&gt; USA &amp; Canada +1-800-635-5577&gt; Brazil +55-11-3616-6607&gt; China (Beijing) +86-10-6410-8669&gt; China (Shanghai) +86-21-6887-8820&gt; Germany +49-89/96-05-88-0&gt; Japan (Osaka) +81-6-6399-8211&gt; Japan (Tokyo) +81-3-5282-5261&gt; South Korea +82-2-3471-9531&gt; United Kingdom +44-118-944-8000</p><p>Check our web site for a current listing of our worldwide distributors. www.moleculardevices.com</p><p>for reseArcH use only. not for use in diAgnostic procedures. </p><p>the trademarks used herein are the property of molecular devices, inc. or their </p><p>respective owners. </p><p>specifications subject to change without notice.</p><p>Systems and provides additional flexibility for the user. SoftMax Pro Software can handle analysis requirements from simple endpoint assays to complex kinetic assays requiring custom calculations. The software is both Windows- and Macintosh-compatible and meets the needs of both basic and power users. Choose from nine different curve-fitting routines and use default data reduction, or set up custom formulas for analysis. Data can be analyzed and combined from different plates. (See Figures 1, 2 and 3.)</p><p>VAlidAtion mAde eAsy</p><p>The SpectraTest Validation Package tests optical performance using NIST-traceable standards. Testing can be done in the users lab on their own schedule. Software validation, FDA 21 CFR Part 11 compliance tools and IQ/OQ/PQ tools are also available.</p><p>tecHnicAl specificAtions</p><p>Photometric PerformanceWavelength range: 340850 nm Wavelength selection: Monochromator, tunable in 1.0 nm incrementsWavelength bandwidth: 2 nm Wavelength accuracy: &lt; 2.0 nmPhotometric range: 04.000 ODPhotometric linearity: (405 nm) 03.000 ODPhotometric accuracy (340850 nm): &lt; 0.006 OD 1.0%, 02.0 ODPhotometric precision (340850 nm): &lt; 0.003 OD 1.0%, 02.0 ODMicroplate read times: Endpoint: 12 seconds Kinetics: 9 second min. interval</p><p>standards for multiple calibration curves and </p><p>unknowns can be run on separate plates.</p><p>flexible template assignment (figure 1)</p><p>IL1a (IL1a Stds: Concentration vs Mean OD)IL1b (IL1b Stds: Concentration vs Mean OD)IL2 (IL2 Stds: Concentration vs Mean OD)</p><p>1 10 100 1,0000</p><p>0.5</p><p>1</p><p>2</p><p>1.5</p><p>mea</p><p>n O</p><p>D 4</p><p>50-6</p><p>50</p><p>concentration pg/ml</p><p>3 Std Curves</p><p>multiple calibration curves (figure 2)</p><p>A0.0960.1740.097</p><p>0.9180.8950.879</p><p>1634.2579814.811339.873</p><p>10.999</p><p>1</p><p>2.1139.4542.949</p><p>B C D R2y = ((A-D /(1 +(x/C)B))+D:</p><p>multiple calibration curves can be plotted on </p><p>one graph.</p><p>results from unknowns run on different plates </p><p>and different calibration curves can be plotted </p><p>on one graph.</p><p>IL1a (IL1a Unks: Number vs MeanConc)IL1b (IL1b Unks: Number vs MeanConc)IL2 (IL2 Unks: Number vs MeanConc)</p><p>1 2 3 4 5 6</p><p>1000</p><p>0</p><p>2000</p><p>3000</p><p>mea</p><p>n co</p><p>ncen</p><p>trat</p><p>ion</p><p>sample number</p><p>ConcBarGraph</p><p>combined data graphing (figure 3)</p><p>molecular devices | 1311 orleans drive | sunnyvale, cA 94089 usA | email: info@moldev.com2010 molecular devices, inc. printed in u.s.A. 6/10 #0120-1330d</p></li></ul>

Recommended

View more >