  • Power

    Ventilation technologyCOMPAIR

    Ventilation technology

  • Ventilation technology

  • Ventilation technology

    COMPAIR flow 150 (system 150)The range for top flow performance

    Page 197-214

    COMPAIR flow 125 (system 125)Strong for fresh and waste air technology

    Page 215-232

    COMPAIR flow round 125 (System 125)High in volume and easy to install

    Page 241-246

    COMPAIR top (system 125 flat)High performance ventilation Page 247-260

    COMPAIR hosesProblem-free connection Page 267-270

    169

    77

    COMPAIR norm (system 100)The range for a good indoor climate

    Page 261-266

    218

    55

    108

    55

    COMPAIR flow round 150 (system 150)High in volume and easy to install

    Page 233-240

    Flexible system solutionsremove your kitchen vapours

    Ventilation technologyCOMPAIR

  • Flexible system solutionsremove your kitchen vapours

    They should be as inconspi-cuous as possible. Adjust to thevariable pressure of high-perfor-mance fans in island and wall-mounted hoods - and still lookgood.

    To fulfil all the technical air flowand architectural demands ofmodern exhaust and supply airyou have to offer a wide rangeof highly flexible flat duct systems.

    COMPAIR systems with theirspecifically constructed diameter geometry areoptimally constructed for exhaust air routing in kitchenswith permanently low backpressure. This is the outcome ofin-house developments and productions which are perfectlyengineered down to the last detail.

    Ventilation technology

    194/16 GB

  • Ventilation technology

    The advantages of exhaust air technology start where others stop...

    The recirculating hood can beused in areas where exhaust airoperation isnt feasible or only possible after expensive structuralchanges. As a kitchen sales expert, in individual kitchen planning, you should always mention to your clients thatrecirculating hoods arent a goodalternative to exhaust hoods. Stiftung Warentest's statement (test8/2007) could be seen as anargument for the more effective useof exhaust hoods: "No charcoalfilter can absorb cooking smells aseffectively as an exhaust duct canextract them."

    The fact that recirculating hoodsarent at all able to clear the humidity in kitchen fumes is another problem which, with growing insulationawareness, can over time lead tomildew, which poses a health risk.

    With the COMPAIR range weoffer you technically sophisticatedair duct technology for individualexhaust air solutions whenplanning new constructions andrefurbishments. While developingthe products we made a point ofbeing in constant dialogue withuniversities and research institutions.

    The focus was on harmonising theenergy efficient usage of systemparts with powerful exhaust hoods.

    Recirculating air example

    195/16 GB

  • Ventilation technology

    Exhaust air example

    Reasons for exhaust air technology: Everything you need to know in anutshell Smells, dampness and carbonmonoxide (gas stoves) are almost completely diverted to theoutside.

    Due to the removal of dampnessthe danger of long term healthrisks (allergies etc.) due tomildew infestation are reducedand also damage caused bycondensed water can be avoided (i.e. swelling up ofwooden surfaces).

    Given the same construction andvolume flow, an exhaust hoodcombined with a fluidic adapted

    air duct/wall conduct installationis much less noisy than a recirculating hood.

    The costs for the necessarychanging of the activatedcarbon filter in a recirculating air system are much higher than forthe installation of an exhaustduct including the wall conduct(calculation basis 15 years/3 changes per year).

    Heat losses are minimised by theuse of a wall conduct, like theCOMPAIR flow Star, that onlyopens when the cooker hood isin operation. Since during recir-culating air operation extra ventilation is usually needed, theheat losses should be com -parable.

    The replacement air neededduring the exhaust air operationcan get to the cooking areathrough a window, door gap oranother air supply opening*.

    *Secure air supply openings are alwaysstipulated when an exhaust hood and anambient air-dependent furnace are in -stalled in dwellings. The smallest solution isa contact switch, that automatically closesthe exhaust hood when the window is closed. Alternatively, an electrical windowdrive that is controlled by the on/off switchof the exhaust hood can be installed. Thisavoids the window staying openconstantly.

    The advantages of exhaust air technologystart where others stop...

    196/16 GB

  • Ventilation technology

    A

    B

    A

    B

    Fitting exampleDeflector 900 with round pipe 150(MF-UR 500/900) for 150hood connectionVentilation pipe (MF-VRD 1000)Horizontal pipe bend 90 (MF-RBH 90)Pipe connector (MF-RVB)Telescopic wall conduct (T-KLIMA-R 150/150)

    CDE

    C

    B

    D

    B

    C

    E

    B

    flow Star GTS 150 Page 200Wall conducts 150 Page 200-201E-Klima A/Z 150 Page 202E-Jal HK flow 150 Page 202.1external blindExternal blinds 150 Page 203Flat duct pipes 150 Page 204Pipe connectors 150 Page 204Pipe bends 150 Page 204-206Deflectors 150 Page 205-206Flat duct sets 150 Page 207End piece 150 Page 207Roof ventilator 150 Page 208Roof hood 150 Page 208Plug-in connector 150/160 Page 209Fastening clamp 150/160 Page 209Window contact switch Page 209-210Wireless temperature sensor Page 210Wall connector 150 Page 210Silencers 150 Page 211Flat duct mounts 150 Page 211Hose clamp 152 Page 211Round pipes 150 Page 211Pipe connectors round 150 Page 211Reducer 150 Page 211Condensing water Page 212separator 150 Duct tape Page 212Backpressure shutter 150 Page 212Fresh air round grid Page 212Filter Page 212Base ventilation grid Page 213Ventilation duct casing Page 214

    The size sets performance standards

    System 150COMPAIR flow 150bion 150

  • Ventilation technology

    COMPAIRMore performance through"conduction"

    As a result of the patented guidevane technology, vapour flows aresmoothed in the duct and directed tothe environment with very little lossof pressure. Using COMPAIR flow150, up to 79 % less pressure islost, depending on the length andstructure of the waste air duct witha cross-sectional increase of only2.9 %, compared with the 150round pipe.

    Strikingly unobtrusive form

    Using the modern COMPAIR flow150 rectangular profile, freedom ofdesign is retained in kitchen plan-ning. The external system dimen-sions H 89 mm x W 222 mm andcorner radiuses of 20 mm enableyou to plan inconspicuously and ina space-saving way.

    Full range for top performance

    COMPAIR flow 150 by Naber is leading air duct techno-logy, which you can order according to your requirementsand on a consignment basis. Typical Naber: if the orderquantity is 10 pc. or more, component sets can be put together individually according to your wishes.

    F-VRO 1000 System 150 Flat duct pipewhite 1000 mm 4043001

    F-RVB 150Pipe connectorswhite 80 mm 4043005

    F-UR 150Deflector 90 with pipe white 4043002

    F-Bion 150 Deflector 90white 4043048

    F-UR 150Deflector 90 with pipewhite 500 mm 4043012white 1000 mm 4043013

    F-RBV 150Round bend vertical 90white 4043004

    F-RBV 150Round bend horizontal 90white 4043004

    F-EST 150End piecewhite 4043006

    E-Jal flow 150External blindstainless steel 4022038

    Klima-E 150wall conductwhite/stainless steel 4022039

    K-Klima-R 150/150wall conductwhite 4044047brown 4044048brick red 4044049

    Flow speed and pressure loss in comparison of systems

    without guide vane with guide vanes

    high speed

    uneven flow

    low speed

    even flow

    without guide vane with guide vanes

    high pressure loss

    lowpressure loss

    flow

    spe

    ed (m

    /s)

    stat

    ic p

    ress

    ure

    (Pa)

    Energy efficiency for extremelypowerfull hoods

    Bionik deals with the research andthe systematic transfer of solutionsfrom nature to technical applica-tions. For COMPAIR bion the flowdynamics optimal meandering systems in watercourses formed thenatural example.The development of the deflectorwas carried out using the latest simu-lation and measurement technology.Here, the focus was on the energyefficient use of the system parts withextremely powerfull hoods.

    All COMPAIR bion deflectors canalso be subsequently integrated intoexisting systems taking the ductgeometry into account.

    Flow speed and pressure loss in systems comparison

    Flow detachment No flow detachment

    High pressure loss Low pressure loss

    222 i

    89 i

    flow 150bion 150

    198/16 GB

  • COMPAIR flow Star GTS 150The first wall conduct with guide vane technology

    Optimum flow under inclusion of the wall conduct on the external wallis decisive for the overall efficiency of any kitchen waste air system.The flow Star wall conduct enables the combination of good flowperformance, perfect seal of the wall joint with "blower door" certifi-cate and prize-winning external appearance. Performance figures andenergy efficiency may be improved even more by connection to theCOMPAIR flow flat duct system.

    The functional principle of flow Star uses the pressure effect of the airstream (volume stream) created during hood operation, combined withmechanically controlled spring and magnetic force when openingand/or closing the wall conduct. With flow Star GTS 150, the highenergy generated by the large flow cross-section is absorbed by anadditional integrated pressure spring. With the hood switched off, thefront plate closes flush with the outside wall.With its modern, flush exterior appearance, flow-Star meets the expectations of modern kitchen planning and architecture.

    Advantages

    optimal flow performance due to integrated guide vanetechnology

    lowest drop in pressure of all commercially available wall conducts

    maximum flow rate of the exhaust hood minimisation of noise emissions by the extractor hood

    Energy efficiency

    no other power supplies are necessary for theuse of the wall conduct. Uses the flow energygenerated by the air stream (volume flow)when the cooker hood is in operation.

    optimal heat isolation when closed an all-round labyrinth seal prevents heat lossand saves heating energy (high tightness)

    perfect solution for a secure sealing of thebuilding shell acc. ENEV09 (Blower-Door certificate)

    appropriate for energy efficient houses the electricity consumption of the connectedcooker hood is reduced due to flow optimisation

    Material & design

    elegant, contemporary design rust free and high class stainless steel cover the cover can be disassembled without any problems for extra handling (i.e. surface coating)

    multiple awards for design and functionNomination for the Design Award 2011 of the Federal Republic of Germany

    Technology

    fully mechanically controlled opening and closing function withspring and magnetic force

    robust construction with ball bearings that are sealed and dontrust

    a backpressure shutter isnt necessary with the hood switched off, the front plate made of stainlesssteel closes flush with the outside wall

    simple assembly without electrical connection, no extra boreholes are necessary

    ideal for the exchange of old systems with existing tapping drillhole

    fail safe against freezing, strong winds, driving rain and dirt

    Ventilation technology

    199/16 GB

  • flow Star GTS 150 wall conduct GTS stands for "generation two springs", which refers to the two integratedsprings. Compared to the original flow Star, a pressure spring has been added,which slows the flow body over the last 10 mm, thus avoiding a hard impact onthe end stops. The kinetic energy created during the opening process is absorbedand released again in the closing direction, against the volume flow. In this way,the opening width of the flow Star GTS is individually adapted to the specificvolume flow of the hood.An all-round sealing lip positioned at the outer flangeprovides added protection in colder weather.

    Properties and functions optimum flow performance due to guide vane technology elegant design (smooth surfaces instead of lamellas) closing of the wall conduct by spring force and additional magnets easy installation without additional drill holes sturdy design with no-rust, sealed ball bearings lowest pressure loss of all commercially available wall conducts maximum feed performance of the vapour hood low noise generation of the vapour hood optimum heat insulation increased resistance to weathering no rattling of backpressure shutters in case of gusts of wind good seal when the vapour hood is switched off blower door certificate no electrical connection required for the installation of the mounting pipe, a core drilling hole ( 155 mm) isrecommended

    214 mmRetraction path

    1

    50 m

    m

    314 500 mm

    86 mm Tap hole 155 mmTilt max. 2

    2

    20 m

    m

    flow Star GTS 150 wall conductWith connection to round pipe 150 mm and round external stainless-steelcover. minimum pressure: 150 Pa stainless steel cover: 220 mm hose/pipe connector : 150 a mm connector depth: 24 mm installation depth: 314 500 mm, wall penetration : about 155 mm for the installation of the mounting pipe, a core drilling hole ( 155 mm) is recommended

    4043040 white/stainless steel

    flow Star GTS 150 F wall conductWith connection to COMPAIR flow 150 rectangular tube and round externalstainless-steel cover. minimum pressure: 150 Pa stainless steel cover: 220 mm tube connector: 227 x 94 a mm, connector depth: 80 mm installation depth: 314 - 500 mm wall penetration : about 155 mm for the installation of the mounting pipe, a core drilling hole ( 155mm) isrecommended

    4043041 white/stainless steel

    200/16 GB

    COMPAIR flow 150 (system 150) Item/DescriptionOrder no.Ventilation technology

  • Klima-E 150 wall conductWith backpressure shutter, telescopic pipe and stainless-steel external blind. hose/tube connector : 150 a mm connector depth: 24 mm installation depth: 420 - 620 mm wall penetration: about 155 mm

    4022039 white/stainless steel

    Klima-E flow 150 wall conductWith backpressure shutter and stainless-steel external blind.With rectangular connector for COMPAIR flow 150. tube connector: 227 a x 94 a mm connector depth: 80 mm installation depth: 420 - 620 mm wall penetration : about 155 mm

    4022040 white/stainless steel

    Klima-Blow-E 150 wall conductWall conduct incl. backpressure shutter and fly screen, telescopic pipe and stainless-steel external blind. hose/tube connector : 150 a mm connector depth: 24 mm installation depth: 420 - 620 mm wall penetration: about 155 mm

    4022023 white/stainless steel

    Klima-E 150 wall conductWith backpressure shutter, stainless steel pipe 500 mm long, 120 mm sliderelement and stainless-steel external blind. hose/tube connector : 150 a mm wall penetration: about 155 mm

    4022044 stainless steel

    K-Klima-R 150/150 wall conductWith backpressure shutter, telescopic pipe and external blind. hose/tube connector : 150 a mm connector depth: 24 mm installation depth: 420 - 620 mm wall penetration : about 155 mm4044047 white4044048 brown4044049 brick red

    Klima-E flow 150 wall conductWith backpressure shutter and external blind.With rectangular connector for COMPAIR flow 150. tube connector: 227 a x 94 a mm connector depth: 80 mm installation depth: 420 - 620 mm wall penetration: about 155 mm4044050 white4044051 brown4044052 brick red

    Ventilation technology

    COMPAIR flow 150 (system 150) Item/DescriptionOrder no.

    201/16 GB

  • Klima 150 waste and fresh air wall conductEvery vapour extraction system also needs "air to breathe":

    Without a supply of fresh air, a vacuum is created in the room, which makes aircirculation and therefore perfect functioning of ventilation impossible. Besidesthis, an exchange of spent and fresh air ensures a comfortable and healthy roomand working climate.

    But it is not always possible to effect the ideal spatial separation of air intake andoutlet. Using the combined waste and fresh air wall conducts, an elementcombining both functions in one compact component has been created.

    190

    Fresh air element

    190

    190

    190

    Waste air element

    E-Klima A/Z 150 waste and fresh air wall conductTwo-piece wall conduct with separate exhaust and fresh air elements. The twostainless steel design external blinds in modern lamella look with internal backpressure shutters solve even spatially difficult installation situations. An internalstainless steel cover on the waste air element can be pushed over the plastic pipeand completely covers the wall penetration. On the supply side there is a gridoutlet with a connector on the round pipe.Both elements can be used next to each other as a set, or as single elements.Optimum flow values are achieved through volume-flow controlled waste andfresh air openings. The fresh air flap only opens with negative pressure.When installed with an open-flue chimney, please coordinate this with thechimney sweep responsible. stainless steel external blind: 190 x 190 mm per blind round waste air connection: 150 a mm installation depth: 490-690 mm wall penetration: ca. 155 mm per element4044053

    40440564044055

    202/16 GB

    COMPAIR flow 150 (system 150) Item/DescriptionOrder no.Ventilation technology

    Waste and fresh air wall conduct

    Waste air elementFresh air element

  • Ventilation technology

    COMPAIR flow 150 (system 150) Item/DescriptionOrder no.

    202.1/16 GB

    E-Jal HK flow 150 external blindThe stainless steel external blind COMPAIR E-Jal HK offers additional possibilitiesfor laying the exhaust air system in difficult installation situations. Through avertical assembly position, it is now possible to place the air duct and theexternal blind upright in a minimum of space without reducing the flow characteristics of the duct system.

    The COMPAIR E-Jal HK is installed in the desired place on the external wall. Theupright flat duct COMPAIR flow 150 is installed in a space-saving manner on thewall coming from the extractor hood and attached directly to the external blindwithout changing the cross-section.

    The aesthetics of the classic, factual design language of the established andaward-winning COMPAIR E-Jal series were taken up and adapted to the newform. The torsionally rigid construction of the stainless steel frame element meansit does not even deform in case of long-term use and weathering. The lamella design of the stainless steel external blinds with spring-loaded back pressure flapsreliably prevents the penetration of strong wind and driving rain.

    E-Jal HK flow 150 external blindStainless steel external blind 150 x 300 mm with back pressure flap for connection 222 x 89 mm to COMPAIR flow 150. connection piece depth: 120 mm

    4022029 stainless steel

  • 202.2/16 GB

    COMPAIR flow 150 (system 150) Item/DescriptionOrder no.Ventilation technology

  • E-Jal flow 150 external blind290 x 160 mm, with backpressure shutter for connection 222 x 89 mm toCOMPAIR flow 150.

    connector depth: 120 mm

    4022038 stainless steel

    E-Jal 150 external blind190 x 190 mm with backpressure shutter for connection to round pipe. connector depth: 145 mm

    4022012 stainless steel, 150 a mm

    E-Jal 180 external blind240 x 240 mm with backpressure shutter for connection to round pipe. connector depth: 145 mm

    4022030 stainless steel, 180 a mm

    E-Jal 200 external blind240 x 240 mm with backpressure shutter for connection to round pipe. connector depth: 145 mm

    4022031 stainless steel, 200 a mm

    E-Jal Blow 150 external blind190 x 190 mm with backpressure shutter and fly screen for connection to roundpipe. connector depth 145 mm

    4022019 stainless steel, 150 a mm

    190

    190

    71

    K-Jal 150 external blind190 x 190 mm, with backpressure shutter for connection to round pipes. 150 a mm connector depth: 71 mm

    4044044 white4044045 brown4044046 brick red

    Ventilation technology

    COMPAIR flow 150 (system 150) Item/DescriptionOrder no.

    203/16 GB

  • COMPAIR flow 150 COMPAIR flow 150, with integrated guide vane technology, is themost advanced air duct system.

    COMPAIR bion 150 effectively conducts the exhaust air of extremely highperformance hoods.

    COMPAIR flow 150 reduces pressure loss, optimises volume flowand protects the fan motor.

    COMPAIR bion 150 minimises noise development due toreduced pressure loss.

    COMPAIR flow 150 is recommended by leading manufacturers of kitchenhoods.

    F-VRO 1000 system 150 flat ductVentilation pipe without sleeve. length 1000 mm

    4043001 white

    F-RVB pipe connectorFor straight ventilation pipes (F-VRO 1000). length 80 mm

    4043005 white

    F-RBH 150 pipe bend horizontal 90With guide vanes and sleeves integrated on both sides.

    4043003 white

    F-RBH 150 pipe bend horizontal 15With sleeve integrated on one side.

    4043007 white

    204/16 GB

    COMPAIR flow 150 (system 150) Item/DescriptionOrder no.Ventilation technology

  • Flow detachment No flow detachment

    High pressure loss Low pressure loss

    Flow speed and pressure loss in comparison of systems

    F-bion 150 deflector 90Energy efficiency for extremely powerful hoods

    Bionik deals with the research and the systematic transfer of solutions from natureto the technical applications of products. For COMPAIR bion, the flow-dynami-cally optimal meandering systems in watercourses formed the natural example.The development of the deflector was carried out using the latest simulation andmeasurement technology. Here, the focus was on the energy efficient use of thesystem parts with extremely powerful hoods.

    Contrary to the trend of constructing large space-consuming duct systems with 180 mm or 200 mm for powerful hoods, for which the installation space isoften lacking, with the help of the new deflection curve Naber COMPAIR F-bion,the proven space-saving flat duct system Naber Compair can be optimised.Using the bionically shaped 90 deflector F-bion, the pressure is reduced by upto 80 % compared to conventional 90 bends without guide-vane technology.Thanks to this reduction in pressure loss, larger volume flows can be channelledmore efficiently and virtually noiselessly from the hood to the outside.

    The COMPAIR bion deflectors for the Naber COMPAIR exhaust air systems125/150 can also be subsequently integrated into existing systems taking theduct geometry into account and significantly improve the extraction power ofthe hood.

    Pressure loss bendCOMPAIR flow and bionat 300 m3/h

    flow bend

    bion bend

    flow 125 bend

    Pres

    sure

    loss

    [Pa]

    bion125 bend

    30

    25

    20

    15

    10

    5

    0

    27,3

    5,3

    226a150i

    98a242

    295

    199

    R 105

    253

    F-bion 150 deflector 90Energy efficient solution for extremely high performance hoods.For direct hood connection with integrated sleeve.

    For the installation, please note the space needed due to the component size!

    4043048 whiteVentilation technology

    COMPAIR flow 150 (system 150) Item/DescriptionOrder no.

    205/16 GB

  • F-RBV 150 pipe bend vertical 90With guide vanes and sleeves integrated on both sides.

    4043004 white

    F-RBFLEX 1 system 150 pipe bendFor diversions and turns up to 180.Adapter, flexible, rectangular to rectangular, with integrated sleeve. length 240 - 600 mm

    4043042 white

    F-RBFLEX 2 system 150 pipe bendFor diversions and turns up to 180.Adapter, flexible, round to rectangular, with integrated sleeve. length 160 - 550 mm

    4043043 white

    F-UR 150 deflector 90For direct hood connection with guide vanes and sleeve integrated on one side.

    4043002 white

    F-UR 150 deflector 90 with round pipeDeflector 90 with guide vanes and round pipe.

    To achieve optimum flow performance, always use the deflectors with round pipe.Only use the deflectors with hose (F-URX 500/F-URX 1000) in exceptional cases,if no other engineering option exists.

    4043012 white, L 500 mm4043013 white, L 900 mm

    F-URX 150 deflector 90 with flexi-hoseDeflector 90 with guide vanes, flexihose and 2 hose clips.

    4043014 white, L 500 mm4043015 white, L 1000 mm

    206/16 GB

    COMPAIR flow 150 (system 150) Item/DescriptionOrder no.Ventilation technology

  • flow 150 flat duct set 1With guide vanes.

    Set consisting of: 2 x 1000 mm flat duct pipe (4043001) 1 x deflector with 900 mm round pipe (4043013) 1 x connecting sleeve (4043005) 1 x end piece/transition piece (4043006)

    4040010

    flow 150 flat duct set 2With guide vanes.

    Set consisting of: 3 x 1000 mm flat duct pipe (4043001) 1 x deflector with 900 mm round pipe (4043013) 1 x pipe bend 90, horizontal (4043003) 2 x connecting sleeve (4043005) 1 x end piece/transition piece (4043006)

    4040011

    F-EST 150 end pieceWith integrated sleeve for direct transition from flat to round (wall penetration).Optimised for flow.

    4043006 white

    Ventilation technology

    COMPAIR flow 150 (system 150) Item/DescriptionOrder no.

    207/16 GB

    white

    white

  • Roof ventilator 150Roof penetration with round connector 150. The base plate offers securemounting on the rafters, the lead collar enables installation on almost any tiledroof.For safety and liability reasons, we would like to point out that installation mayonly be carried out by a roofer.

    300

    w. 148400

    640

    150

    150

    300

    430

    flow 150 roof ventilatorWith 150 round connector without backpressure shutter.

    4043021 stainless steel

    DN 150/160 roof hoodThe optimally designed roof hoods work with extremely low pressure loss, sinceair flow is largely without resistance. This is the advantageous effect of the amplydimensioned cross-section reserves of the hood heads: with the same nominalwidth, the clear profiles of the upper pipe and the hood head are always clearlylarger than those of the ventilation pipes to be connected.The unique sandwich system provides for an absolutely secure mount of theuniversal pass-through roofing tile on the lath. A specially shaped mounting platemade of galvanised steel plate makes the roof penetration extremely stable.

    DN 150/160 roof hoodThe universal roofing tile is quickly and securely mounted. Due to the Z edge ofthe bracket plate it immediately achieves a secure grip and may comfortably bemoved to the exact installation point on the roof batten. Two rust-free screws (notincluded) are recommended for secure fastening.With universal lead-coloured pass-through roofing tile for rooves with a tilt angleof 25 - 45. Without backpressure shutter.

    4024024 natural red4024023 black

    208/16 GB

    COMPAIR flow 150 (system 150) Item/DescriptionOrder no.Ventilation technology

  • Plug-in connector 150/160Made of aluminium, symmetrical version for connecting roof hoods to ventilationducts, at the top matching the roof hood, at the bottom matching the insidedimensions of the ventilation ducts, no discharge of condensed water at the joint,perfect aerodynamic design.Suitable for all wrapped seam tubes 150/160.Reduction from 167 mm i to 149 mm a.Are required for all roof hoods.

    4024011 aluminium

    Fastening clamp 150/160Made of galvanized steel strips with joint for storm-proof fastening of the verti-cally aligned roof hood to the roof construction; suitable for all roof angles.Are required for all roof hoods.

    4024014 galvanized

    COCO

    Window contact switch wireless systemWith external antennae. Whenever an extractor unit such as an extractor hood and an open fireplace -such as a stove - are operated simultaneously, with thewindows closed there is the risk of fatal carbon monoxide poisoning. To preventthis hazard, in the firing ordinance M-FeuVO, the legislator prescribes that incase of simultaneous operation of a fireplace dependent on ambient air and anextractor unit, it has to be insured that no dangerous negative pressure occursand a sufficient amount of outdoor air is able to flow in - for example through anopen window or a ventilation flap.Using a window contact switch queries if the window is open, to ensure thesupply of fresh air.To guarantee safe functioning even under difficult reception conditions, theproven model of the window contact switch has been extended with an externalantenna. A typical application of the window contact switch with externalantenna is the installation of the receiver unit of the exhaust switch for exhausthoods with stainless steel flue casing. This metal casing largely shields the internalantenna of the radio-controlled switch unit so the signals from the radio trans-mitter can only be received to a limited extent or not at all. Here the externalantenna offers a remedy! It is mounted on the outside of the metal casing andguarantees unimpeded reception of the control signals. A 1000 mm longantenna cable connects the external antenna to the exhaust switch unit.

    Window contact switch radio systemSafety switch with wireless radio transmission via an external antennae for appli-cation under difficult reception circumstances, such as installation behind stainlesssteel casing. Ready to plug with transmitter and receiver, including installationmaterial and batteries (long life, low energy consumption).Switching capacity up to 1150 W (5 A)

    7051001

    Ventilation technology

    COMPAIR flow 150 (system 150) Item/DescriptionOrder no.

    209/16 GB

    white, with external antennae

  • Window contact switch cable systemSafety switch with cable breakage monitoring and re-plugging safeguard.Ready to plug in with 6 m sensor cable, incl. mounting material. No batteriesrequired.

    Switching capacity up to 1400 W (6 A)

    7051004

    Wireless temperature sensorThe wireless temperature sensor is integrated into the radio system of the windowcontact switch. Here, the temperature of the operating state of the fireplace ismonitored. The window only needs to be opened with the fireplace in operationwhile the hood is active. Thus, the strict coupling of the active hood and openwindow is not necessary. The temperature sensor is suitable for installation inclosed and dry living areas.

    A hand riveter is required for installation!

    model PT 1000 5 mm length 100 mm temperature range -50 to 500 C sensor cable 800 mm, up to 300 C

    7051005

    150 Wall connector 1For connection to round pipe 150 with backpressure shutter. hose/pipe connector 150 a mm connector depth 24 mm round pipe with 350 mm length wall penetration ca. 155 mm

    4043025 white

    150 Wall connector 2For connection to flow rectangular pipe with backpressure shutter. pipe connector 227 x 94 a mm connector depth 80 mm round pipe with 350 mm length wall penetration ca. 155 mm

    4043028 white

    210/16 GB

    COMPAIR flow 150 (system 150) Item/DescriptionOrder no.Ventilation technology

    white

    white

  • 366250

    15

    150

    212

    Silencer aluminium 150Extremely robust design through use of thick aluminium pipe.25 mm/16 kg per m glass wool insert, the sound is reduced to 22 dBdepending on the frequency, DIN 4102/A1 length 460 mm connection 150 a mm

    4043029 aluminium

    Flat duct bracket 150For laying flat ducts on ceilings and walls.

    4043019 stainless steel

    Hose clamp 152Clip made of galvanized steel wire. nominal diameter 140 - 160 mm

    4021133 aluminium coloured

    350

    500

    900

    150i

    Round pipe 150Suitable for deflectors. pipe 150 i mm

    4043008 white, L 350 mm4043009 white, L 500 mm4043010 white, L 900 mm

    158

    59

    152,4

    149,8 152,4

    R-VBS 150 round pipe connectorFor connecting two pieces of pipe and hose. 155 i mm length 60 mm

    4052017 white

    129,5

    152,4

    9020

    20

    132,9

    156,6

    RDZ flow 125/150 reducerFor connecting 150 mm pipe to 125 mm pipe. Reversible installationpossible flow-optimised design by avoiding sharp edges that stall the flow.

    4011048 white

    Ventilation technology

    COMPAIR flow 150 (system 150) Item/DescriptionOrder no.

    211/16 GB

  • 125

    239,

    5

    148

    25

    125 148 185

    KDA flow 125/150 condensing water separatorPrevents return flow of condensing water to the hood in case of vertical waste airrouting.Flow-optimised design by avoiding sharp edges that stall the flow.Two-sided connection of hoses and pipes to 125 mm and 150 mm possible.When connected to 150 mm, the -125 section has to be separated at thecutting line provided.

    4043018 white

    N-KLEB PVC duct tapeFor secure connection of hoses to system parts. width: 50 mm length: 10 m = 1 roll

    4021128 white

    Backpressure shutter 150Round with backpressure shutter.Not suitable for installing a vertical pipe. : 150 a mm length: 62 mm

    4043030 galvanised

    T-ZULRG 150 fresh air round gridFor outside and inside. 150a mm connector depth 25 mm for secure pipe/hose installation

    4041015 white

    Grease filterThe high-performance flat hood filter with saturation indicator. For all hoodswith an installation size of 600 mm. Bleached without chlorine.

    8033017 2 filters

    Activated charcoal filterThe effective vapour filter, may be combined with a flat filter.

    8033019 2 filters

    212/16 GB

    COMPAIR flow 150 (system 150) Item/DescriptionOrder no.Ventilation technology

  • Base ventilation grid 1Slatted ventilation grid in aluminium. Can be used as a return flow opening incase of circulating air units positioned in the base. The necessary cross-sectionarea for the passage of air specified by the hood manufacturer is to be observed!This results in the number of grids required. Installation is carried out by screwingbefore the base cut-out.

    Ventilation diameter: ca. 265 cm

    8033012 silver, W 84 mm, L 480 mm

    Base ventilation grid 2Slatted ventilation grid in aluminium. Can be used as a return flow opening incase of circulating air units positioned in the base. The necessary cross-sectionarea for the passage of air specified by the hood manufacturer is to be observed!This results in the number of grids required. Installation is carried out by screwingbefore the base cut-out.

    Ventilation diameter: ca. 327 cm

    8033013 silver, W 104 mm, L 480 mm

    Ventilation technology

    COMPAIR flow 150 (system 150) Item/DescriptionOrder no.

    213/16 GB

  • COMPAIR ventilation duct casingWith the COMPAIR ventilation duct casing, form and function are at yourcommand! The chipboard casing can be individually decorated using paint orwall-paper for more harmonious integration as a wall or island hood in anymodern kitchen.An additional benefit is provided by the use of lighting in the COMPAIR ventilation duct casing, putting the working area of your kitchen in the right light.

    Exhaust air routing to the right/left to the outside wall, or for aesthetic reasonsover the entire wall length. The rectangular bar is mounted on the wall andceiling. Then the L-panel can be attached.

    The casing has a height of 220 mm and is therefore also able to accommodatea round duct with unproblematic transition to a wall conduct. For individual adjustment, the casing is simply reduced in height, or shortened.

    For all COMPAIR systems.

    COMPAIR ventilation duct casing wall solutionThe casing is made of 16 mm thick chipboard, bonded and equipped with dowelholes on both sides. Each 1,000 mm part includes a dowelled end piece, whichenables series construction (endless system).

    For all COMPAIR systems.

    H 220 mm x W 300 mm x L 1,000 mm including end cap

    4041010 L-shape

    COMPAIR ventilation ductWith the COMPAIR ventilation duct casing, form and function are at yourcommand! The chipboard casing can be individually decorated using paint orwall-paper for more harmonious integration as a wall or island hood in anymodern kitchen.An additional benefit is provided by the use of lighting in the COMPAIR ventila-tion duct casing, putting the working area of your kitchen in the right light.

    At 435 mm, the width of the casing is sufficient for the hood duct to be screwedin the same position in a different direction. For individual adjustment, the casingis also simply reduced in height, or shortened.

    Next to the hood duct, a reinforcing element (sector 18 mm) is needed. This isinserted in the required position and screwed on. To mount the flue, this provideschipboard with a total thickness of 32 mm (2 x 16 mm).

    For all COMPAIR systems.

    COMPAIR ventilation duct casing island solutionThe casing is made of 16 mm thick chipboard, bonded and equipped with dowelholes on both sides. It is also designed so that the rectangular bars are attachedto the ceiling first. Each 1,000-mm part includes a dowelled end piece, whichenables series construction (endless system). For all COMPAIR systems. H 220 mm x W 435 mm x L 1,000 mm including end cap reinforcing plate: H 16 mm x W 401 mm x L 401 mm4041011 U-shape4041012 Reinforcing plate

    214/16 GB

    COMPAIR flow 150 (system 150) Item/DescriptionOrder no.Ventilation technology

  • 169

    77

    A

    B

    A

    B

    Fitting exampleDeflector 900 with round pipe 125(MF-UR 500/900) for 125 hood connectionVentilation pipe (MF-VRD 1000)Horizontal pipe bend 90 (MF-RBH 90)Pipe connector (MF-RVB)Telescopic wall conduct (T-KLIMA-R 125/125)

    CDE

    C

    B

    D

    B

    C

    E

    B

    Ventilation technology

    flow Star 125 GTS Page 218Wall conducts 125 Page 218-219V-Klima A/Z 125 Page 220External blinds 125 Page 220-221Flat duct pipes 125 Page 221-222Pipe connectors 125 Page 222Pipe bends 125 Page 222-224Deflectors 125 Page 223-224End piece 125 Page 224Flat duct sets 125 Page 225Roof hood 125 Page 226Plug-in connector 125 Page 226Fastening clamps 125 Page 226Window contact switch Page 227Wireless temperature sensor

    Page 228

    Wall connector 125 Page 228Silencer 125 Page 228Flat duct mounts 125 Page 228Hose clamp 125 Page 229Round pipes 125 Page 229Pipe connectors round 125 Page 229Reducer 125 Page 229Condensing water separator 125

    Page 229

    Duct tape Page 230Fresh air grid 125 Page 230Backpressure shutter 125 Page 230Filter Page 230Base ventilation grid Page 231Ventilation duct casing Page 232

    Strong for fresh andwaste air technology

    System 125COMPAIR flow 125bion 125

  • 216/16 GB

    Ventilation technology

    MF-VRO 1000System 125Flat duct pipewhite 1000 mm 4033002

    MF-VRM 1000System 125Flat duct pipe with sleevewhite 1000 mm 4033004

    MF-RVB 125Pipe connectorwhite 61 mm 4033005

    F-Bion 125 Deflector 90white 4033031

    MF-UR 125 Deflector 90with pipe connectorwhite 4033010

    MF-UR 125Deflector 90with round pipewhite 500 mm 4033008white 1000 mm 4033009

    MF-RBH 125Pipe bend horizontal 90white 4033011

    MF-RBV 125Pipe bend vertical 90white 4033013

    K-KLIMA-R 125/125Wall conductwhite 4021073brick red 4021075brown 4021074

    MF-EST 125End piecewhite 4033014

    COMPAIRMore performance through "conduction"

    As a result of the patented guidevane technology, vapour flows aresmoothed in the duct and directed tothe environment with very little lossof pressure. Using COMPAIR flow125, up to 59 % less pressure islost, depending on the length andstructure of the waste air duct witha cross-sectional increase of only3.9 %, compared with the 125round pipe.

    Strikingly unobtrusive form

    Using the modern COMPAIR flow125 rectangular profile, freedom ofdesign is retained in kitchen plan-ning. The external system dimen -sions H 77 mm x W 169 mm andcorner radiuses of 20 mm enableyou to plan inconspicuously and ina space-saving way.

    Full range for top performance

    COMPAIR flow 125 by Naber is leading air duct techno-logy, which you can order according to your requirementsand on a consignment basis. Typical Naber: if the orderquantity is 10 pc. or more, component sets can be put together individually according to your wishes.

    Flow speed and pressure loss in comparison of systems

    without guide vane with guide vanes

    high speed

    uneven flow

    low speed

    even flow

    without guide vane with guide vanes

    high pressure loss

    lowpressure loss

    flow

    spe

    ed (m

    /s)

    stat

    ic p

    ress

    ure

    (Pa)

    Energy efficiency for extremelypowerfull hoods

    Bionik deals with the research andthe systematic transfer of solutionsfrom nature to technical applica-tions. For COMPAIR, the flow dyna-mics optimal meandering systems inwatercourses formed the naturalexample. The development of thedeflector was carried out using thelatest simulation and measurementtechnology. Here, the focus was onthe energy efficient use of the systemparts with extremely powerfullhoods.

    All COMPAIR bion deflectors canalso be subsequently integrated intoexisting systems taking the duct geometry into account.

    Flow detachment No flow detachment

    High pressure loss Low pressure loss

    Flow speed and pressure loss in comparison of systems

    222 i

    89 i

    flow 125bion 125

  • 217/16 GB

    COMPAIR flow Star GTS 125The first wall conduct with guide vane technology

    Optimum flow under inclusion of the wall conduct on the external wallis decisive for the overall efficiency of any kitchen waste air system.The flow Star wall conduct enables the combination of good flowperformance, perfect seal of the wall joint with "blower door" certifi-cate and prize-winning external appearance. Performance figures andenergy efficiency may be improved even more by connection to theCOMPAIR flow flat duct system.

    The functional principle of flow Star uses the pressure effect of the airstream (volume stream) created during hood operation, combined withmechanically controlled spring and magnetic force when openingand/or closing the wall sleeve. With the hood switched off, the frontplate closes flush with the outside wall.With its modern, flush exterior appearance, flow-Star meets the expectations of modern kitchen planning and architecture.

    Ventilation technology

    Advantages

    optimal flow performance due to integrated guide vanetechnology

    lowest drop in pressure of all commercially available wall conducts

    maximum flow rate of the exhaust hood minimisation of noise emmissions by the extractor hood

    Energy efficiency

    no other power supplies are necessary for theuse of the wall conduct. Uses the flow energygenerated by the air stream (volume flow)when the cooker hood is in operation.

    optimal heat isolation when closed an all-round labyrinth seal prevents heat lossand saves heating energy (high tightness)

    perfect solution for a secure sealing of thebuilding shell acc. ENEV09 (Blower-Door certificate)

    appropriate for energy efficient houses the electricity consumption of the connectedcooker hood is reduced due to flow optimisation

    Material & design

    elegant, contemporary design rust free and high class stainless steel cover the cover can be disassembled without any problems for extra handling (i.e. surface coating)

    multiple awards for design and functionNomination for the Design Award 2011 of the Federal Republic of Germany

    Technology

    fully mechanically controlled opening and closing function withspring and magnetic force

    robust construction with ball bearings that are sealed and dontrust

    a backpressure shutter isnt necessary with the hood switched off, the front plate made of stainlesssteel closes flush with the outside wall

    simple assembly without electrical connection, no extra boreholes are necessary

    ideal for the exchange of old systems with existing tapping drillhole

    fail safe against freezing, strong winds, driving rain and dirt

  • flow Star GTS 125 wall conductGTS stands for "generation two springs", which refers to the two integratedsprings. Compared to the original flow Star, a pressure spring has been added,which slows the flow body over the last 10 mm, thus avoiding a hard impact onthe end stops. The kinetic energy created during the opening process is absorbedand released again in the closing direction, against the volume flow. In this way,the opening width of the flow Star GTS is individually adapted to the specificvolume flow of the hood.An all-round sealing lip positioned at the outer flangeprovides added protection in colder weather.

    Properties and functions optimum flow performance due to guide vane technology elegant design (smooth surfaces instead of lamellas) closing of the wall conduct by spring force and additional magnets easy installation without additional drill holes sturdy design with no-rust, sealed ball bearings lowest pressure loss of all commercially available wall conducts maximum feed performance of the vapour hood low noise generation of the vapour hood optimum heat insulation increased resistance to weathering no rattling of backpressure shutters in case of gusts of wind good seal when the vapour hood is switched off blower door certificate no electrical connection required for the installation of the mounting pipe, a core drilling hole ( 132 mm) isrecommended

    214 mmRetraction path

    1

    25 m

    m

    314 500 mm

    86 mm Tap hole 132 mmTilt max. 2

    flow Star GTS 125 wall conductWith connection to round pipe 125 mm and round external stainless-steelcover. minimum pressure: 100 Pa stainless steel cover: 197 mm hose/pipe connector : 125 a mm connector depth: 24 mm installation depth: 314 500 mm, wall penetration : about 132 mm for the installation of the mounting pipe, a core drilling hole ( 132 mm) is recommended

    4033042 white/stainless steel

    174a

    82a

    flow Star GTS 125 F wall conductWith connection to COMPAIR flow rectangular 125 tube and round external stainless-steel cover. minimum pressure: 100 Pa stainless steel cover: 197 mm tube connector: 174 x 82 a mm, connector depth: 80 mm installation depth: 314 500 mm, wall penetration : about 132 mm for the installation of the mounting pipe, a core drilling hole ( 132 mm) is recommended

    4033043 white/stainless steel

    218/16 GB

    COMPAIR flow 125 (system 125) Item/DescriptionOrder no.Ventilation technology

  • Klima-E 125 wall conductWith backpressure shutter, telescopic pipe and stainless-steel external blind. hose/tube connector : 125 a mm connector depth: 24 mm installation depth: 420 - 620 mm wall penetration : about 132 mm

    4022013 white/stainless steel

    82a

    174a

    Klima-E flow 125 wall conductWith backpressure shutter, telescopic pipe and stainless-steel external blind.With rectangular connector for COMPAIR flow 125. pipe connector: 174 a x 82 a mm connector depth: 80 mm installation depth: 420 - 640 mm wall penetration : about 132 mm

    4033022 white/stainless steel

    Klima-Blow-E 125 wall conductWith backpressure shutter and fly screen, telescopic pipe and stainless-steelexternal blind. hose/tube connector : 125 a mm connector depth: 24 mm installation depth: 420 - 620 mm wall penetration : about 132 mm

    4022022 white/stainless steel

    E-Klima-E 125 wall conductWith backpressure shutter, stainless steel pipe 500 mm long, 120 mm sliderelement and stainless-steel external blind. hose/tube connector : 125 a mm wall penetration : about 132 mm

    4022043 stainless steel

    K-Klima-R 125/125 wall conductWith backpressure shutter, telescopic pipe and external blind. hose/tube connector : 125 a mm connector depth: 24 mm installation depth: 420 - 620mm wall penetration : about 132 mm

    4021073 white4021074 brown4021075 brick red

    82a

    174a

    K-Klima-R flow 125 wall conductWith backpressure shutter and external blind.With rectangular connector for COMPAIR flow 125. pipe connector: 174 a x 82 a mm connector depth: 80 mm installation depth: 420 - 620 mm wall penetration : about 132 mm4033027 white4033028 brown4033029 brick red

    Ventilation technology

    COMPAIR flow 125 (system 125) Item/DescriptionOrder no.

    219/16 GB

  • Klima 125 waste and fresh air wall conductEvery vapour extraction system also needs "air to breathe":

    Without a supply of fresh air, a vacuum is created in the room, which makes aircirculation and therefore perfect functioning of ventilation impossible. Besidesthis, an exchange of spent and fresh air ensures a comfortable and healthy roomand working climate.

    But it is not always possible to effect the ideal spatial separation of air intake andoutlet. Using the combined waste and fresh air wall conducts, an elementcombining both functions in one compact component has been created. Itrequires only a single wall breakthrough and is accordingly inconspicuous on theoutside.

    235-430

    V-Klima A/Z 125 waste and fresh air wall conduct 1With telescopic pipe and stainless-steel external blind 250 x 280 mm with roundconnection 100, 120 and 125 mm. You need a piece of pipe or hose from the end piece of the wall conduct to theflat duct. installation depth: 235 - 430 mm wall penetration: about 220 x 190 mmWhen installed with an open-flue chimney, please coordinate this with the chimney sweep responsible.4022026 white/stainless steel

    V-Klima A/Z 125 waste and fresh air wall conduct 2With telescopic pipe and white external blind 220 x 255 mm, with pipe connection 100, 120 and 125 mm.You need a piece of pipe or hose from the end piece of the wall conduct to theflat duct. installation depth: 235 - 440 mm wall penetration: about 220 x 190 mmWhen installed with an open-flue chimney, please coordinate this with thechimney sweep responsible.4022027 white

    E-Jal flow 125 external blind210 x 140 mm with backpressure shutter for connection 169 x 77 mm toCOMPAIR flow 125. connector depth: 90 mm

    4033015 stainless steel

    E-Jal 125 external blind190 x 190 mm with backpressure shutter for connection to round pipe. connector depth: 145 mm

    4022011 stainless steel, 125 a mm

    220/16 GB

    COMPAIR flow 125 (system 125) Item/DescriptionOrder no.Ventilation technology

  • E-Jal Blow 125 external blind190 x 190 mm with backpressure shutter and fly screen for connection to roundpipe. connector depth 145 mm

    4022015 stainless steel, 125 a mm

    190

    190

    71

    K-Jal 125 external blind190 x 190 mm, with backpressure shutter for connection to round pipes. 125 a mm connector depth: 71 mm

    4021070 white4021071 brown4021072 brick red

    COMPAIR flow 125 COMPAIR flow 125, with integrated guide vane technology, is themost advanced air duct system

    COMPAIR bion 125 effectively conducts the exhaust air of extremely highperformance hoods

    COMPAIR flow 125 reduces pressure loss, optimises volume flowand protects the fan motor

    COMPAIR bion 125 minimises noise development due toreduced pressure loss

    COMPAIR flow 125 is recommended by leading manufacturers of kitchenhoods

    MF-VRO 500 system 125 flat duct pipeVentilation pipe without sleeve. length 500 mm

    4033001 white

    MF-VRO 1000 system 125 flat duct pipeVentilation pipe without sleeve. length 1000 mm

    4033002 white

    Ventilation technology

    COMPAIR flow 125 (system 125) Item/DescriptionOrder no.

    221/16 GB

  • MF-VRM 500 system 125 flat duct pipeVentilation pipe with sleeve. length 500 mm

    4033003 white

    MF-VRM 1000 system 125 flat duct pipeVentilation pipe with sleeve. length 1000 mm

    4033004 white

    61a

    MF-RVB 125 pipe connectorConnector for flat ducts. length 61 mm

    4033005 white

    234 a

    MF-RBH 125 90 pipe bend horizontal 90With guide vanes and sleeves integrated on both sides.

    4033011 white

    MF-RBH 125 pipe bend horizontal 15With sleeve integrated on one side.

    4033012 white

    MF-RBV 125 pipe bend vertical 90With guide vanes and sleeves integrated on both sides.

    4033013 white

    222/16 GB

    COMPAIR flow 125 (system 125) Item/DescriptionOrder no.Ventilation technology

  • Flow speed and pressure loss in systems comparison

    Flow detachment No flow detachment

    High pressure loss Low pressure loss

    F-bion 125 deflector 90Energy efficiency for extremely powerful hoods

    Bionik deals with the research and the systematic transfer of solutions from natureto the technical applications of products. For COMPAIR bion the flow-dynami-cally optimal meandering systems in watercourses formed the natural example.The development of the deflector was carried out using the latest simulation andmeasurement technology. Here, the focus was on the energy efficient use of thesystem parts with extremely powerful hoods.

    Contrary to the trend of constructing large space-consuming duct systems with 180 mm or 200 mm for powerful hoods, for which the installation space isoften lacking, with the help of the new deflection curve Naber COMPAIR F-bion,the proven space-saving flat duct system Naber Compair can be optimised. Usingthe bionically shaped 90 deflector F-bion, the pressure is reduced by up to 80 %compared to conventional 90 bends without guide-vane technology. Thanks tothis reduction in pressure loss, larger volume flows can be channelled more effi-ciently and virtually noiselessly from the hood to the outside.

    The COMPAIR bion deflectors for the Naber COMPAIR exhaust air systems125/150 can also be subsequently integrated into existing systems taking theduct geometry into account and significantly improve the extraction power of thehood.

    Pressure loss bendCOMPAIR flow and bionat 300 m3/h

    flow bend

    bion bend

    flow 150 bend

    Pres

    sure

    loss

    [Pa]

    bion 150 bend

    30

    25

    20

    15

    10

    5

    0

    13,6

    2,0

    173a125i

    272

    86a220

    177

    R 94

    229

    F-bion 125 deflector 90Energy efficient solution for extremely high performance hoods.For direct hood connection with integrated sleeve.

    For the installation, please note the space needed due to the component size!

    4033031 whiteVentilation technology

    COMPAIR flow 125 (system 125) Item/DescriptionOrder no.

    223/16 GB

  • MF-UR 125 deflector 90Deflector with guide vanes and pipe connector, and sleeveintegrated on one side.

    4033010 white

    MF-UR 125 deflector 90 with round pipeDeflector 90 with guide vanes and round pipe.To achieve optimum flow performance, always use the deflectors with round pipe.Only use the deflectors with hose (MF-URX) in exceptional cases, if no other engi-neering option exists.

    4033008 white, L 500 mm4033009 white, L 900 mm

    MF-URX 125 deflector 90 with flexi-hoseWith guide vanes and 2 hose clips.

    4033006 white, L 500 mm4033007 white, L 1000 mm

    MF-RBFLEX 1 system 125 pipe bendFor diversions and turns up to 180. Adaptor, flexible, rectangular to rectangular.With connecting sleeve integrated on both sides. length 240 - 600 mm

    4033023 white

    MF-RBFLEX 2 system 125 pipe bendFor diversions and turns up to 180.Adapter, flexible, round to rectangular. length 160 - 550 mm

    4033024 white

    125 i

    MF-EST end pieceWith integrated sleeve for direct transition from flat to round(wall penetration).

    4033014 white

    224/16 GB

    COMPAIR flow 125 (system 125) Item/DescriptionOrder no.Ventilation technology

  • flow 125 flat duct set 1Set consisting of: 2 x 1000 mm flat duct pipe without sleeve (4033002) 1 x deflector with 900 mm round pipe (4033009) 1 x pipe connector (4033005)

    4033040

    flow 125 flat duct set 2Set consisting of: 3 x 1000 mm flat duct pipe without sleeve (4033002) 1 x deflector with 900 mm round pipe (4033009) 1 x pipe bend 90, horizontal (4033011) 2 x pipe connector (4033005)

    4033041

    Ventilation technology

    COMPAIR flow 125 (system 125) Item/DescriptionOrder no.

    225/16 GB

    white

    white

  • DN 125 roof hood The optimally designed roof hoods work with extremely low pressure loss, sinceair flow is largely without resistance. This is the advantageous effect of the amplydimensioned cross-section reserves of the hood heads: with the same nominalwidth, the clear profiles of the upper pipe and the hood head are always clearlylarger than those of the ventilation pipes to be connected.The unique sandwich system provides for an absolutely secure mount of theuniversal pass-through roofing tile on the lath. A specially shaped mounting platemade of galvanised steel plate makes the roof penetration extremely stable.

    DN 125 roof hoodThe universal roofing tile is quickly and securely mounted. Due to the Z edge ofthe bracket plate it immediately achieves a secure grip and may comfortably bemoved to the exact installation point on the roof lath. Two rust-free screws (notincluded) are recommended for secure fastening.With universal lead-coloured pass-through roofing tile for rooves with a tilt anglevon 25 - 45. Without backpressure shutter.4024020 black4024021 natural red

    Plug-in connector 125Made of aluminium, symmetrical version for connecting roof hoods to ventilationducts, at the top matching the roof hood, at the bottom matching the insidedimensions of the ventilation ducts, no discharge of condensed water at the joint,perfect aerodynamic design.Suitable for all wrapped seam tubes 125Reduction from 132 mm i to 124 mm aAre required for all roof hoods.

    4024012 aluminium

    Fastening clamp 125Made of galvanized steel strips with joint for storm-proof fastening of the verti-cally aligned roof hood to the roof construction; suitable for all roof angles.Are required for all roof hoods.

    4024013 galvanized

    226/16 GB

    COMPAIR flow 125 (system 125) Item/DescriptionOrder no.Ventilation technology

  • COCO

    Window contact switch wireless systemWith external antennae. Whenever an extractor unit - such as an extractor hood -and an open fireplace -such as a stove - are operated simultaneously, with thewindows closed there is the risk of fatal carbon monoxide poisoning. To preventthis hazard, in the firing ordinance M-FeuVO, the legislator prescribes that incase of simultaneous operation of a fireplace dependent on ambient air and anextractor unit, it has to be insured that no dangerous negative pressure occursand a sufficient amount of outdoor air is able to flow in - for example through anopen window or a ventilation flap.Using a window contact switch queries if the window is open, to ensure thesupply of fresh air.To guarantee safe functioning even under difficult reception conditions, theproven model of the window contact switch has been extended with an externalantenna. A typical application of the window contact switch with externalantenna is the installation of the receiver unit of the exhaust switch for exhausthoods with stainless steel flue casing. This metal casing largely shields the internalantenna of the radio-controlled switch unit so the signals from the radio trans-mitter can only be received to a limited extent or not at all. Here the externalantenna offers a remedy! It is mounted on the outside of the metal casing andguarantees unimpeded reception of the control signals. A 1000 mm longantenna cable connects the external antenna to the exhaust switch unit.

    Window contact switch radio systemSafety switch with wireless radio transmission via an external antennae for appli-cation under difficult reception circumstances, such as installation behind stainlesssteel casing. Ready to plug with transmitter and receiver, including installationmaterial and batteries (long life, low energy consumption).Switching capacity up to 1150 W (5 A)

    7051001

    Window contact switch cable systemSafety switch with cable breakage monitoring and re-plugging safeguard. Readyto plug in with 6 m sensor cable, incl. mounting material. No batteries required.

    Switching capacity up to 1400 W (6 A)

    7051004Ventilation technology

    COMPAIR flow 125 (system 125) Item/DescriptionOrder no.

    227/16 GB

    white, with external antennae

    white

  • Wireless temperature sensorThe wireless temperature sensor is integrated into the radio system of the windowcontact switch. Here, the temperature of the operating state of the fireplace ismonitored. The window only needs to be opened with the fireplace in operationwhile the hood is active. Thus, the strict coupling of the active hood and openwindow is not necessary. The temperature sensor is suitable for installation inclosed and dry living areas.

    A hand riveter is required for installation!

    model PT 1000 5 mm length 100 mm temperature range -50 to 500 C sensor cable 800 mm, up to 300 C

    7051005

    125 Wall connector 1For use in chimney shafts.For connection to round pipe 125 with backpressure shutter. hose/tube connector : 125 a mm connector depth: 24 mm round tube with a length of 350 mm wall penetration: ca. 132 mm

    4020040 white

    82a

    174a

    125 Wall connector 2For use in chimney shafts.For rectangular connection to COMPAIR flow 125, with backpressure shutter. hose/pipe connector 174 a x 82 a mm connector depth 80 mm round pipe with 350 mm length wall penetration ca. 132 mm

    4033026 white

    366250

    15

    125

    187

    Silencer 125Extremely robust design through use of thick aluminium pipe.25 mm/16 kg per m3 glass wool insert, reduces the sound to 22 dB dependingon the frequency, DIN 4102/A1 length: 475 mm connection: 125 a mm

    4033034 aluminium

    169

    77

    Flat duct mount 125For secure mounting of freely routed ducts and hoses on walls/ceilings.

    4033025 stainless steel

    228/16 GB

    COMPAIR flow 125 (system 125) Item/DescriptionOrder no.Ventilation technology

    white

  • Hose clamp 127Clip made of galvanized steel wire. nominal diameter 120 - 140 mm

    4021132 aluminium coloured

    Round pipe 125Round pipe 130 a = 125 i mm

    4021114 white, L 350 mm4021118 white, L 500 mm4021121 white, L 900 mm

    50

    T-VBS 125 pipe connector round hose/pipe connector : 125 a mm length: 50 mm

    4021127 white

    104,5

    129,5

    9020

    20

    107,9

    133,6

    RDZ flow 100/125 reducerFor connecting 125 mm pipe to 100 mm. Reversible installation possible flow-optimised design by avoiding sharp edges that stall the flow.

    4011049 white

    129,5

    152,4

    9020

    20

    132,9

    156,6

    RDZ flow 125/150 reducerFor connecting 150 mm pipe to 125 mm pipe. Reversible installationpossible flow-optimised design by avoiding sharp edges that stall the flow.

    4011048 white

    125

    239,

    5

    148

    25

    125 148 185

    KDA flow 125/150 condensing water separatorPrevents return flow of condensing water to the hood in case ofvertical waste air routing.Flow-optimised design by avoiding sharp edges that stall the flow.Two-sided connection of hoses and pipes to 125 mm and 150mm possible. When connected to 150 mm, the -125 section has to be separated at the cutting line provided.

    4043018 white

    Ventilation technology

    COMPAIR flow 125 (system 125) Item/DescriptionOrder no.

    229/16 GB

  • N-KLEB PVC duct tapeFor secure connection of hoses to system parts. width: 50 mm length: 10 m = 1 roll

    4021128 white

    T-ZULRG 125 round fresh air gridFor outside and inside. 125 a mm connector depth: 25 mm for secure pipe/hose assembly

    4021148 white

    Backpressure shutter 125Round with backpressure shutter.Not suitable for installing a vertical pipe. : 125 a mm length: 50 mm

    4021104 galvanised

    Grease filterThe high-performance flat hood filter with saturation indicator. For all hoodswith an installation size of 600 mm. Bleached without chlorine.

    8033017 2 filters

    Activated charcoal filterThe effective vapour filter, may be combined with a flat filter.

    8033019 2 filters

    230/16 GB

    COMPAIR flow 125 (system 125) Item/DescriptionOrder no.Ventilation technology

  • Base ventilation grid 1Slatted ventilation grid in aluminium. Can be used as a return flow opening incase of circulating air units positioned in the base. The necessary cross-sectionarea for the passage of air specified by the hood manufacturer is to be observed!This results in the number of grids required. Installation is carried out by screwingin front of the base cut-out.

    Ventilation diameter: ca. 265 cm

    8033012 silver, W 84 mm, L 480 mm

    Base ventilation grid 2Slatted ventilation grid in aluminium. Can be used as a return flow opening incase of circulating air units positioned in the base. The necessary cross-sectionarea for the passage of air specified by the hood manufacturer is to be observed!This results in the number of grids required. Installation is carried out by screwingin front of the base cut-out.

    Ventilation diameter: ca. 327 cm

    8033013 silver, W 104 mm, L 480 mm

    Ventilation technology

    COMPAIR flow 125 (system 125) Item/DescriptionOrder no.

    231/16 GB

  • COMPAIR ventilation duct casingWith the COMPAIR ventilation duct casing, form and function are at yourcommand! The chipboard casing can be individually decorated using paint orwall-paper for more harmonious integration as a wall or island hood in anymodern kitchen.An additional benefit is provided by the use of lighting in the COMPAIR ventila-tion duct casing, putting the working area of your kitchen in the right light.

    Exhaust air routing to the right/left to the outside wall, or for aesthetic reasonsover the entire wall length. The rectangular bar is mounted on the wall andceiling. Then the L-panel can be attached.

    The casing has a height of 220 mm and is therefore also able to accommodatea round duct with unproblematic transition to a wall conduct. For individual adjustment, the casing is simply reduced in height, or shortened.

    For all COMPAIR systems.

    COMPAIR ventilation duct casing wall solutionThe casing is made of 16 mm thick chipboard, bonded and equipped with dowelholes on both sides. Each 1,000 mm part includes a dowelled end piece, whichenables series construction (endless system).

    For all COMPAIR systems.

    H 220 mm x W 300 mm x L 1,000 mm including end cap

    4041010 L-shape

    COMPAIR ventilation ductWith the COMPAIR ventilation duct casing, form and function are at yourcommand! The chipboard casing can be individually decorated using paint orwall-paper for more harmonious integration as a wall or island hood in anymodern kitchen.An additional benefit is provided by the use of lighting in the COMPAIR ventila-tion duct casing, putting the working area of your kitchen in the right light.

    At 435 mm, the width of the casing is sufficient for the hood duct to be screwedin the same position in a different direction. For individual adjustment, the casingis also simply reduced in height, or shortened.

    Next to the hood duct, a reinforcing element (sector 18 mm) is needed. This isinserted in the required position and screwed on. To mount the flue, this provideschipboard with a total thickness of 32 mm (2 x 16 mm).

    For all COMPAIR systems.

    COMPAIR ventilation duct casing island solutionThe casing is made of 16 mm thick chipboard, bonded and equipped with dowelholes on both sides. It is also designed so that the rectangular bars are attachedto the ceiling first. Each 1,000-mm part includes a dowelled end piece, whichenables series construction (endless system). For all COMPAIR systems. H 220 mm x W 435 mm x L 1,000 mm including end cap reinforcing plate: H 16 mm x W 401 mm x L 401 mm4041011 U-shape4041012 Reinforcing plate

    232/16 GB

    COMPAIR flow 125 (system 125) Item/DescriptionOrder no.Ventilation technology

  • Ventilation technology

    B

    A

    B

    A

    B

    A

    A

    B

    Fitting exampleRound pipe(R-1000)Pipe bend 90 (R-RBV)Telescopic pipe wall element(K-KLIMA-R 125/125)

    C

    C

    flow Star GTS 150 Page 235Wall conducts 150 Page 235External blinds 150 Page 235-236Exhaust and fresh air Page 236Round duct pipe 150 Page 237Pipe connector 150 Page 237Pipe bend 150 Page 237Deflectors 150 Page 237Wall connector 150 Page 237Round duct mount 150 Page 238Backpressure shutters 150 Page 238Fresh air round grid Page 238Filter Page 238Base ventilation grid Page 237

    High in volume and easy to install

    System 150COMPAIR flow round

  • Ventilation technology

    COMPAIR flow round 150System 150

    High in volume and easy to install

    COMPAIR flow round base parts impress withuniversal applicability and perfect air flow. Allsystem components may be interconnected bysimple plug connection.If 10 or more are ordered, sets may be assembled individually according to your wishes.

    Absolutely efficient

    COMPAIR flow round is the most efficientround pipe system ever created.

    Proven guide vane technology

    COMPAIR flow round uses the proven turningvane technology.

    Low pressure loss

    COMPAIR flow round maximises the hoodefficiency and minimises noise developmentthrough 70 % less pressure loss.

    Installation close to corners

    COMPAIR flow round can be laid close tocorners thanks to its very small inner radius.

    R-1000system 150 round pipewhite, 1000 mm 4052102

    R-VBS 150 round pipe/connectorwhite, 60 mm 4052017

    R-RVB flow 150pipe bend 90white 4052015

    R-URX flow 150 deflector90 with flexi-hosewhite 500 mm 4052019white 1000 mm 4052021

    K-JAL 150 external blindwhite 4044044brown 4044045brick red 4044046

    K-KLIMA-R 150/150 wall conductwhite 4044047brown 4044048brick red 4044049

    N-PXO 152 flexi-hose roundwhite 4023004

    APXO 152alu. flexi-hose roundalumin. 4023007

    N-SKLEMM 152 hose clampalu. col. 4021133

    Conventional round pipe bend COMPAIR flow round bend Conventional round pipe bend COMPAIR flow round bend

    Pressure loss with COMPAIR flow round 150.

    234/16 GB

  • flow Star GTS 150 wall conductWith connection to round pipe 150 mm and round external stainless-steelcover. minimum pressure: 150 Pa stainless steel cover: 220 mm hose/pipe connector : 150 a mm connector depth: 24 mm installation depth: 314 500 mm, wall penetration : about 155 mm for the installation of the mounting pipe, a core drilling hole ( 155 mm) is recommended

    4043040 white/stainless steel

    Klima-E 150 wall conductWith backpressure shutter, telescopic pipe and stainless-steel external blind. hose/tube connector : 150 a mm connector depth: 24 mm installation depth: 420 - 620 mm wall penetration: about 155 mm

    4022039 white/stainless steel

    Klima-E 150 wall conductWith backpressure shutter, stainless steel pipe 500 mm long, 120 mm sliderelement and stainless-steel external blind. hose/tube connector : 150 a mm wall penetration: about 155 mm

    4022044 stainless steel

    K-Klima-R 150/150 wall conductWith backpressure shutter, telescopic pipe and external blind. hose/tube connector : 150 a mm connector depth: 24 mm installation depth: 420 - 620 mm wall penetration : about 155 mm4044047 white4044048 brown4044049 brick red

    E-Jal 150 external blind190 x 190 mm with backpressure shutter for connection to round pipe. connector depth: 145 mm

    4022012 stainless steel, 150 a mm

    E-Jal Blow 150 external blind190 x 190 mm with backpressure shutter and fly screen for connection to roundpipe. connector depth 145 mm

    4022019 stainless steel, 150 a mm

    Ventilation technology

    COMPAIR flow round (system 150) Item/DescriptionOrder no.

    235/16 GB

  • 190

    190

    71

    K-Jal 150 external blind190 x 190 mm, with backpressure shutter for connection to round pipes. 150 a mm connector depth: 71 mm

    4044044 white4044045 brown4044046 brick red

    Klima 150 waste and fresh air wall conductEvery vapour extraction system also needs "air to breathe":

    Without a supply of fresh air, a vacuum is created in the room, which makes aircirculation and therefore perfect functioning of ventilation impossible.Besides this, an exchange of spent and fresh air ensures a comfortable andhealthy room and working climate.

    But it is not always possible to effect the ideal spatial separation of air intake andoutlet. Using the combined waste and fresh air wall conducts, an elementcombining both functions in one compact component has been created.

    190

    Fresh air element

    190

    190

    190

    Waste air element

    E-Klima A/Z 150 waste and fresh air wall conductTwo-piece wall conduct with separate exhaust and fresh air elements. The twostainless steel design external blinds in modern lamella look with internal backpressure shutters solve even spatially difficult installation situations. An internalstainless steel cover on the waste air element can be pushed over the plastic pipeand completely covers the wall penetration. On the supply side there is a gridoutlet with a connector on the round pipe.Both elements can be used next to each other as a set, or as single elements.Optimum flow values are achieved through volume-flow controlled waste andfresh air openings. The fresh air flap only opens with negative pressure.When installed with an open-flue chimney, please coordinate this with thechimney sweep responsible. stainless steel external blind: 190 x 190 mm per blind round waste air connection: 150 a mm installation depth: 490-690 mm wall penetration: ca. 155 mm per element4044053

    40440564044055

    236/16 GB

    COMPAIR flow round (system 150) Item/DescriptionOrder no.Ventilation technology

    Waste and fresh air wall conduct

    Waste air elementFresh air element

  • 1000

    150i

    R-1000 round pipe 150 150 i mm length 1000 mm

    4052102 white

    158

    59

    152,4

    149,8 152,4

    R-VBS 150 round pipe connectorFor connecting two pieces of pipe and hose. 155 i mm length 60 mm

    4052017 white

    157

    1

    57

    211,5

    211,

    5

    23

    23

    40,5

    2

    153

    1

    5348

    ,5

    48,5

    R-RBV flow 150 pipe bend 90Low-loss deflection due to integrated guide vane. With sleeves integrated on bothsides. also suitable for direct hood connection up to 70% less pressure loss through guide vane technology. This results inconsiderably increased performance at reduced noise generation.

    can be laid close to corners due to its very small inner radius. optimal transition to all wall conducts with round connector. 153 i mm4052015 white

    L (Schlauch) = 500/1000

    153 i

    R-URX flow 150 deflector 90 with flexi-hoseWith 500/1000 mm flexihose and 2 hose clips. 150 mm

    40520194052021

    150 Wall connector 1For connection to round pipe 150 with backpressure shutter. hose/pipe connector 150 a mm connector depth 24 mm round pipe with 350 mm length wall penetration ca. 155 mm

    4043025 white

    Ventilation technology

    COMPAIR flow round (system 150) Item/DescriptionOrder no.

    237/16 GB

    white, L 500 mmwhite, L 1000 mm

  • 7

    158

    16580

    152

    Round duct mount 150For wall and ceiling mounting. recommended spacing 0.5 mm

    4052110 white, 150 a mm

    Backpressure shutter 150Round with backpressure shutter.Not suitable for installing a vertical pipe. : 150 a mm length: 62 mm

    4043030 galvanised

    T-ZULRG 150 fresh air round gridFor outside and inside. 150a mm connector depth 25 mm for secure pipe/hose installation

    4041015 white

    Grease filterThe high-performance flat hood filter with saturation indicator. For all hoodswith an installation size of 600 mm. Bleached without chlorine.

    8033017 2 filters

    Activated charcoal filterThe effective vapour filter, may be combined with a flat filter.

    8033019 2 filters

    238/16 GB

    COMPAIR flow round (system 150) Item/DescriptionOrder no.Ventilation technology

  • Base ventilation grid 1Slatted ventilation grid in aluminium. Can be used as a return flow opening incase of circulating air units positioned in the base. The necessary cross-sectionarea for the passage of air specified by the hood manufacturer is to be observed!This results in the number of grids required. Installation is carried out by screwingin front of the base cut-out.

    Ventilation diameter: ca. 265 cm

    8033012 silver, W 84 mm, L 480 mm

    Base ventilation grid 2Slatted ventilation grid in aluminium. Can be used as a return flow opening incase of circulating air units positioned in the base. The necessary cross-sectionarea for the passage of air specified by the hood manufacturer is to be observed!This results in the number of grids required. Installation is carried out by screwingin front of the base cut-out.

    Ventilation diameter: ca. 327 cm

    8033013 silver, W 104 mm, L 480 mm

    Ventilation technology

    COMPAIR flow round (system 150) Item/DescriptionOrder no.

    239/16 GB

  • 240/16 GB

    COMPAIR flow round (system 150) Item/DescriptionOrder no.Ventilation technology

  • Ventilation technology

    B

    A

    B

    A

    B

    A

    A

    B

    Fitting exampleRound pipe(R-1000)Pipe bend 90 (R-RBV)Telescopic pipe wall element(K-KLIMA-R 125/125)

    C

    C

    flow Star GTS 125 Page 243Wall conducts 125 Page 243Exhaust and supply air Page 244External blind 125 Page 244-245Round duct pipe 125 Page 245Pipe connectors 125 Page 245Pipe bends 125 Page 245Deflectors 125 Page 245Wall connector 125 Page 246Round duct mount 125 Page 246Backpressure shutter 125 Page 246Filter Page 246

    High in volume and easy to install

    System 125COMPAIR flow round

  • Ventilation technology

    COMPAIR flow round 125System 125

    High in volume and easy to install

    COMPAIR flow round base parts impress withuniversal applicability and perfect air flow. Allsystem components may be interconnected bysimple plug connection.If 10 or more are ordered, sets may be assembled individually according to your wishes.

    Absolutely efficient

    COMPAIR flow round is the most efficientround pipe system ever created.

    Proven guide vane technology

    COMPAIR flow round uses the proven turningvane technology.

    Low pressure loss

    COMPAIR flow round maximises the hoodefficiency and minimises noise developmentthrough 70 % less pressure loss.

    Installation close to corners

    COMPAIR flow round can be laid close to corners thanks to its very small inner radius.

    R-1000system 125 round pipewhite, 1000 mm 4052002

    R-VBS 125 round pipe connector,white 60 mm 4052016

    R-RVB flow 125pipe bend 90white 4052014

    R-URX flow 125 deflector90 with flexi-hosewhite 500 mm 4052018white 1000 mm 4052020

    K-JAL 125 external blindwhite 4021070brown 4021071brick red 4021072

    K-KLIMA-R 125/125 wall conductwhite 4021073brown 4021074brick red 4021075

    N-PXO 127flexi-hose roundwhite 4023002

    A-PXO 127 alu. flexi-hosealuminium 4023006

    N-SKLEMM 127 hoseclampalu. coloured 4021132

    Pressure loss with COMPAIR flow round 125.

    Conventional round pipe bend COMPAIR flow round pipe bend Conventional round pipe bend COMPAIR flow round pipe bend

    242/16 GB

  • flow Star GTS 125 wall conductWith connection to round pipe 125 mm and round external stainless-steelcover. minimum pressure: 100 Pa stainless steel cover: 197 mm hose/pipe connector : 125 a mm connector depth: 24 mm installation depth: 314 500 mm, wall penetration : about 132 mm for the installation of the mounting pipe, a core drilling hole ( 132 mm) is recommended

    4033042 white/stainless steel

    Klima-E 125 wall conductWith backpressure shutter, telescopic pipe and stainless-steel external blind. hose/tube connector : 125 a mm connector depth: 24 mm installation depth: 420 - 620 mm wall penetration : about 132 mm

    4022013 white/stainless steel

    Klima-Blow-E 125 wall conductWith backpressure shutter and fly screen, telescopic pipe and stainless-steelexternal blind. hose/tube connector : 125 a mm connector depth: 24 mm installation depth: 420 - 620 mm wall penetration : about 132 mm

    4022022 white/stainless steel

    E-Klima-E 125 wall conductWith backpressure shutter, stainless steel pipe 500 mm long, 120 mm sliderelement and stainless-steel external blind. hose/tube connector : 125 a mm wall penetration : about 132 mm

    4022043 stainless steel

    K-Klima-R 125/125 wall conductWith backpressure shutter, telescopic pipe and external blind. hose/tube connector : 125 a mm connector depth: 24 mm installation depth: 420 - 620mm wall penetration : about 132 mm

    4021073 white4021074 brown4021075 brick red

    Ventilation technology

    COMPAIR flow round (system 125) Item/DescriptionOrder no.

    243/16 GB

  • Klima 125 waste and fresh air wall conductEvery vapour extraction system also needs "air to breathe":

    Without a supply of fresh air, a vacuum is created in the room, which makes aircirculation and therefore perfect functioning of ventilation impossible. Besidesthis, an exchange of spent and fresh air ensuresa comfortable and healthy room and working climate.

    But it is not always possible to effect the ideal spatial separation of air intake andoutlet. Using the combined waste and fresh air wall conducts, an elementcombining both functions in one compact component has been created. Itrequires only a single wall breakthrough and is accordingly inconspicuous onthe outside.

    235-430

    V-Klima A/Z 125 waste and fresh air wall conduct 1With telescopic pipe and stainless-steel external blind 250 x 280 mm with roundconnection 100, 120 and 125 mm. You need a piece of pipe or hose from the end piece of the wall conduct to theflat duct. installation depth: 235 - 430 mm wall penetration: about 220 x 190 mmWhen installed with an open-flue chimney, please coordinate this with the chimney sweep responsible.4022026 white/stainless steel

    V-Klima A/Z 125 waste and fresh air wall conduct 2With telescopic pipe and white external blind 220 x 255 mm, with pipe connection 100, 120 and 125 mm.You need a piece of pipe or hose from the end piece of the wall conduct to theflat duct. installation depth: 235 - 440 mm wall penetration: about 220 x 190 mmWhen installed with an open-flue chimney, please coordinate this with thechimney sweep responsible.4022027 white

    E-Jal 125 external blind190 x 190 mm with backpressure shutter for connection to round pipe.

    connector depth: 145 mm

    4022011 stainless steel, 125 a mm

    E-Jal Blow 125 external blind190 x 190 mm with backpressure shutter and fly screen for connection to roundpipe. connector depth 145 mm

    4022015 stainless steel, 125 a mm

    244/16 GB

    COMPAIR flow round (system 125) Item/DescriptionOrder no.Ventilation technology

  • 190

    190

    71

    K-Jal 125 external blind190 x 190 mm, with backpressure shutter for connection to round pipes. 125 a mm connector depth: 71 mm

    4021070 white4021071 brown4021072 brick red

    1000

    125i

    R-1000 system 125 round pipe 125 i mm length 1000 mm

    4052002 white

    134

    59

    129,5

    126,5 129,5

    R-VBS 125 round pipe connectorFor connecting two pipes. 130 i mm length 60 mm

    4052016 white

    134

    1

    34

    186,5

    186,

    5

    23

    23

    130

    1

    30

    R-RBV flow 125 pipe bend 90Low-loss deflection via integrated guide vanes. With sleeves integrated on bothsides. 130 i mm also suitable for direct connection up to 70% less pressure loss through guide vane technology. This results inconsiderably increased performance at reduced noise generation.

    can be laid close to corners due to its very small inner radius. optimal transition to all wall conducts with round connector.4052014 white

    L (Schlauch) = 500/1000

    130 i

    R-URX flow 125 deflector 90 with flexi-hoseWith 500/1000 mm flexihose and 2 hose clips. 125 i mm

    40520184052020

    Ventilation technology

    COMPAIR flow round (system 125) Item/DescriptionOrder no.

    245/16 GB

    white, L 500 mmwhite, L 1000 mm

  • 125 Wall connector 1For use in chimney shafts.For connection to round pipe 125 with backpressure shutter. hose/tube connector : 125 a mm connector depth: 24 mm round tube with a length of 350 mm wall penetration: ca. 132 mm

    4020040 white

    7

    158

    16580

    152

    Round duct mount 125For wall and ceiling mounting. recommended spacing 0.5 mm

    4052010 white, 125 a mm

    Backpressure shutter 125Round with backpressure shutter.Not suitable for installing a vertical pipe. : 125 a mm length: 50 mm

    4021104 galvanised

    Grease filterThe high-performance flat hood filter with saturation indicator. For all hoodswith an installation size of 600 mm. Bleached without chlorine.

    8033017 2 filters

    Activated charcoal filterThe effective vapour filter, may be combined with a flat filter.

    8033019 2 filters

    246/16 GB

    COMPAIR flow round (system 125) Item/DescriptionOrder no.Ventilation technology

  • Ventilation technology

    218

    55

    B

    C

    D

    F

    H

    G

    A

    A

    GE

    H

    D FCB

    Fitting exampleDeflector 90 with flexi-hose and2 hose clips (T-URX 500/1000)for 120 and 125 hood connectionWide duct connector (T-RVB)Wide duct (T-VRO 500/1000)Wide duct horizontal pipe bend 90 (T-RBH 90)Wide duct with sleeve (T-VRM 500/1000)Transition piece round/wide duct (T-EST)Telescopic wall conduct(K-KLIMA-R 125/125)

    E

    B

    Wall conducts 125 Page 250V-Klima A/Z 125 Page 251External blind 125 Page 252Wide duct pipes 125 Page 252Wide duct pipe connector 125

    Page 253

    Wide duct pipe bends 125Page 253

    Deflectors 125 Page 253Staggered ring 125 Page 254Y-piece 125 Page 254End piece 125 Page 255Window contact switch Page 255Wireless temperature sensor

    Page 256

    Wall connector 125 Page 256Silencer Page 256Flat duct mounts 125 Page 257Hose clamp Page 257Round pipes 125 Page 257Pipe connectors round 125 Page 257Reducers 125 Page 257Condensing water separator 125

    Page 258

    Duct tapes Page 258Fresh air grid 125 Page 258Backpressure shutters 125 Page 258Filter Page 259

    Powerfulventilation technology

    System 125 flatCOMPAIR top

  • Even for standard installations, COMPAIR

    top basic parts are versatile and in topshape for flow.

    All system parts may beinterconnected bysimple plug connectiontechnology.

    If 10 or more are ordered, sets may be assembled individuallyaccording to your wishes.

    Powerfulventilation technology

    System 125 flatCOMPAIR top

    Ventilation technology

    T-VRO 125 Wide duct without sleevewhite 500 mm 4021001white 1,000 mm 4021002

    T-RVB 125Wide duct connectorwhite 4021004

    T-UR 125/2 Deflector 90white 4021010

    T-UR-ST 125Deflector 90white 4021012

    T-URX 125Deflector 90 with flexi hosewhite 500 mm 4021025white1,000 mm 4021026

    T-RBH 1 System 125Wide duct bendwhite 4021043

    T-RBV 1 System 125Wide duct bendwhite 4021044