NEW 3.0 SOFTWARE FOR SERVO-i AND SERVO-sNEW 3.0 SOFTWARE FOR SERVO-i AND SERVO-s

Page 2: Ventilacion en Neonatos

NEW FUNCTIONALITY FOR SERVO-i VENTILATOR V3.0

Nasal CPAP

Y Sensor measuring

Start-up Configuration possibilities

P0.1

Patient Circuit Test

Reference loop/overlay

Page 3: Ventilacion en Neonatos

ALVEOLAR DEVELOPMENT

Page 4: Ventilacion en Neonatos

PATIENT RANGE

Adult Pediatric Neonate

Page 5: Ventilacion en Neonatos

TRACHEOBRONCHIAL TREE

Page 6: Ventilacion en Neonatos

CONTINUOUS POSITIVE AIRWAY PRESSURE (CPAP)

Delivers a pre-determined continuous pressure

Recruits collapsed alveoli

Improves oxygenation

Stabilizes the chest wall

Inhibits paradoxical movements during inspiration and collapse during expiration

Page 7: Ventilacion en Neonatos

CPAP

Patient Interfaces

Mask Endotracheal tube Nasal prongs

Page 8: Ventilacion en Neonatos

NASAL CPAP

Gives the flow necessary to maintain the pressure set by the user

5 cm H2O 5 cm H2O

Page 9: Ventilacion en Neonatos

NASAL CPAP

5 cm H2O 5 cm H2OContinuous flow CPAP

set flow too lowset flow too high

SERVO-i Nasal CPAP

SERVO-i

P

P

Page 10: Ventilacion en Neonatos

NASAL CPAP – USER INTERFACE

Standby mode:

Press:INFANT

Press: NIV

Page 11: Ventilacion en Neonatos

NASAL CPAP – USER INTERFACE

Selecting Nasal CPAP

Press ”Nasal CPAP”

Page 12: Ventilacion en Neonatos

NASAL CPAP – USER INTERFACE

Selecting Nasal CPAP

Adjust settings as necessary in the usual manner

Start ventilation

PressACCEPT to confirm

From Stand-by mode Pressto start ventilation

Page 13: Ventilacion en Neonatos

NASAL CPAP – USER INTERFACE

All patient-related alarms exceptO2 are inactivated

No ventilation will occur

Waiting position

Page 14: Ventilacion en Neonatos

NASAL CPAP – USER INTERFACE

Information if a disconnectionoccurs

Cannot resume ventilation untilexcessive leakage has beencorrected

“Leakage too high…”

Page 15: Ventilacion en Neonatos

NASAL CPAP – USER INTERFACE

Running Nasal CPAP mode:

Page 16: Ventilacion en Neonatos

NASAL CPAP – USER INTERFACE

Parameters in Nasal CPAP

CPAP

O2 concentration

Page 17: Ventilacion en Neonatos

NASAL CPAP – USER INTERFACE

Alarm Profile

Lower and Upper limit for CPAP alarm.

Upper pressure limit cannot be silenced permanently

Page 18: Ventilacion en Neonatos

NASAL CPAP – USER INTERFACE

Alarm Profile

Turning off Apnea alarm.

Turning off “apnea alarm” function

Page 19: Ventilacion en Neonatos

NASAL CPAP

Functions that are not available with Nasal CPAP

Volume curve

Loops

Open Lung Tool

Additional values

Additional settings

CO2

Page 20: Ventilacion en Neonatos

Y SENSOR MEASURING

Allows measurement of flow and pressure right upto the Y-piece

Page 21: Ventilacion en Neonatos

Y SENSOR MEASURING

Y Sensor measures flow and pressure

Differential pressure device – only measures and monitors

Sampling rate 100 Hz

We compare internal flow and pressure in the SERVO-i with Y Sensor measurement

Page 22: Ventilacion en Neonatos

Y SENSOR MEASURING

Plug and play module

Occupies 2 slots in the module compartment

Y Sensor is disposable

Neonatal/pediatric

Adult

Page 23: Ventilacion en Neonatos

Y SENSOR MEASURING – NEONATAL/PEDIATRIC

Dead space:<0.45 ml installed dead space

Sensor length:5.1 cm (2.0”)

Tubing length:2 meters

Sensor weight:7,5 grams

Flow measuring rate:0.125 to 40 l/min (2-667 ml/s)

Page 24: Ventilacion en Neonatos

Y SENSOR MEASURING - ADULT

Dead space:<9,0 ml installed dead space

Sensor length:84 mm (3.25”)

Tubing length:2 meters

Sensor weight:6.3 grams

Flow measuring rate:2 to 180 l/min (32-3200 ml/s)

Page 25: Ventilacion en Neonatos

Y SENSOR MEASURING

Selected patient category is compared with the connected sensor and alerts when the wrong sensor is in use.

Detects when Y Sensor measuring function is activated.

Immediately informs when the Y Sensor measuring function is deactivated.

When the Y Sensor measurement is disconnected the SERVO-i internal measurement takes over.

Page 26: Ventilacion en Neonatos

Y SENSOR MEASURING

Compliance compensation available

Can be used in all modes of ventilation

Pre-use check ”Y Sensor” – a new test included in the PUC and Patient Circuit Test as soon as the new software is installed.

Page 27: Ventilacion en Neonatos

Y SENSOR MEASURING

Y Sensor

Automatic zeroing

Purge with help of a flow to clean the pressure channels.

Only applicable for exp. Times > 1 second

Only applicable for respiratory rates < 30 breaths per minute

Page 28: Ventilacion en Neonatos

Y SENSOR MEASURING

Y Sensor measurements in Pressure mode

Y Sensor measurement

Page 29: Ventilacion en Neonatos

Y SENSOR MEASURING

Recorded waveforms measured with Y Sensor

Y Sensor measurement

Page 30: Ventilacion en Neonatos

Y SENSOR MEASURING

Messages – Y Sensor module is disconnected

Page 31: Ventilacion en Neonatos

Y SENSOR MEASURING

A message informs the user when zeroing of the Y Sensor is in progress

Zeroing in progress

Page 32: Ventilacion en Neonatos

Y SENSOR MEASURING

Page 33: Ventilacion en Neonatos

START-UP CONFIGURATION

Press to access code panel

Page 34: Ventilacion en Neonatos

CONFIGURATION - START-UP SETTINGS – USER INTERFACE

Key in correct access code

Press to enter “Biomed” window

Page 35: Ventilacion en Neonatos

CONFIGURATION - START-UP SETTINGS – USER INTERFACE

Press Edit Configuration

Page 36: Ventilacion en Neonatos

PressStart-up configuration

CONFIGURATION - START-UP SETTINGS – USER INTERFACE

Page 37: Ventilacion en Neonatos

Patient category

Invasive or Non-Invasive

Minute volume or Tidal Volume

Inspiratory time – I:E or Insp. Timein seconds (s)

Oxygen concentration in Suction Support

Press CANCEL to return to “Biomed”

Press NEXT to configure ventilation mode

CONFIGURATION - START-UP SETTINGS – USER INTERFACE

Page 38: Ventilacion en Neonatos

Select ventilation mode

Press to select the desired ventilation mode

Press CLOSE to return to parameter settings

CONFIGURATION - START-UP SETTINGS – USER INTERFACE

Page 39: Ventilacion en Neonatos

Returns you to previous window where you can check settings or make changes

To return to Standby

To continue

Returns you to factory default ventilation mode settings and parameters

CONFIGURATION - START-UP SETTINGS – USER INTERFACE

Page 40: Ventilacion en Neonatos

Viewing the pre-set configuration

CONFIGURATION - START-UP SETTINGS – USER INTERFACE

Page 41: Ventilacion en Neonatos

Restart the ventilator

CONFIGURATION - START-UP SETTINGS – USER INTERFACE

Page 42: Ventilacion en Neonatos

Copy configuration

CONFIGURATION - START-UP SETTINGS – USER INTERFACE

Page 43: Ventilacion en Neonatos

Alarm sound level

CONFIGURATION - START-UP SETTINGS – USER INTERFACE

Page 44: Ventilacion en Neonatos

Set default alarm sound level

CONFIGURATION - START-UP SETTINGS – USER INTERFACE

Page 45: Ventilacion en Neonatos

Change access code

CONFIGURATION - START-UP SETTINGS – USER INTERFACE

Page 46: Ventilacion en Neonatos

Invalid code

CONFIGURATION - START-UP SETTINGS – USER INTERFACE

Page 47: Ventilacion en Neonatos

P0.1

PO.1 is the negative pressure generated during the first 100 msec of an occluded inspiration

In patients with obstructive lung disease or acute respiratory failure, P0.1 is a useful indicator of their ability to be weaned from mechanical ventilation.

Normal value 1-2 cmH2O

Page 48: Ventilacion en Neonatos

P0.1

Measures all triggered breaths on an average of 8 breaths

Page 49: Ventilacion en Neonatos

P0.1

High P0.1 values:

Reflect an increased neuro-muscular activation of the respiratory system and therefore the development of inspiratory muscle fatigue is extremely likely.

Low P0.1 values:

Indicate successful weaning.

Page 50: Ventilacion en Neonatos

PATIENT CIRCUIT TEST

Page 51: Ventilacion en Neonatos

ADDITIONAL FEATURES

Save and compare reference loops

Current loop

Reference loop

Time for reference loop

Press to save reference loop

Overlay x 2

Page 52: Ventilacion en Neonatos

ADDITIONAL FEATURES

Mute and pre-mute Upper pressure limit

Maximum apnea time in infant settings changed from 15 to 45 secs

In the Suction Support disconnect phase, flow will not resume after 1 minute

High priority alarm activated after 1 min.

Time counter activated upon disconnection

Operator action indicated by a frame around the key instead of a color change

Page 53: Ventilacion en Neonatos

ADDITIONAL FEATURES

Increased apnea time range

Current loop

Page 54: Ventilacion en Neonatos

ADDITIONAL FEATURES

Suction support

Current loop

Page 55: Ventilacion en Neonatos

ADDITIONAL FEATURES

Current action selection

Current loop

Blue frame indicating chosen action

Page 56: Ventilacion en Neonatos

FEATURE ENHANCEMENTS

Additional settings – new help window

Showing some values derived from settings such as inspiration time in seconds and calculated inspiratory flow.

New help window

Page 57: Ventilacion en Neonatos

FEATURE ENHANCEMENTS

Trend graphs

Y sensor measuring active

new

Page 58: Ventilacion en Neonatos

FEATURE ENHANCEMENTS

Trend graphs (cont.)

new

Page 59: Ventilacion en Neonatos

FEATURE ENHANCEMENTS

Trend graphs (cont.)

new

Page 60: Ventilacion en Neonatos

NEW FUNCTIONALITY FOR THE SERVO-s VENTILATOR V3.0

SIMV (PC)+PS

Start-up Configuration

Patient Circuit Test

Mute and pre-mute Upper pressure limit

FiO2 trend

Page 61: Ventilacion en Neonatos