24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 Fireplaces, Heating and Cooling: 705-721-1212 • Grills: 705 726-4278 • napoleonproducts.com VECTOR™ 50 DIRECT VENT LINEAR GAS APPLIANCE W415-1874 / A / 02.04.19 Specifications Front Options Framing Dimensions Model BTU Width Height Depth Viewing Area Actual Framing Actual Framing Actual Framing LV50N-2 36,000 65 5/16 65 13/16 41 3/16 73 19 7/8 20 1/8 52 3/4 X 18 5/8 LV50N2-2 36,000 65 5/16 65 13/16 41 3/16 73 16 3/16 16 3/16 52 3/4 X 18 5/8 single-sided Ref LV50-2 E 20 1/8” (51.1cm) F 65 13/16” (167.2cm) J Optional - Appliance does not need to be elevated above floor *L 73” (185.4cm) E J F minimum framing L note: The LV series requires a minimum enclosure height of 73” measured from the bottom of the appliance. For temperature requirements, this area must be left unobstructed. Some venting configurations that require more vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pipes and combustibles. note: Before framing the appliance, ensure to install the firestop first. see-thru Before framing the appliance, ensure to install the firestop first as it will not fit between the studs if installed after framing. * Minimum enclosure height maybe higher depending on venting configuration (see minimum distance to combustibles). Ref LV50-2 E 16 3/16” (41.1cm) F 65 13/16” (167.2cm) J Optional - Appliance does not need to be elevated above floor *L 73” (185.4cm) E F J minimum framing L note: The LV series requires a minimum enclosure height of 73” measured from the bottom of the appliance. For temperature requirements, this area must be left unobstructed. Some venting configurations that require more vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pipes and combustibles. note: Product information provided is not complete and is subject to change without notice. Please consult the installation manual for the most up to date installation information. 1 1 4 " MAX ADJUSTMENT MIN. PROJECTION FROM FINISHING MATERIAL 3 8 " 53 7 16 " 47 3 8 " 19 3 4 " 12 15 16 " SLF50K/SS PSB50SS/K 17 9 16 " 14 1 8 " 1 1 4 " MAX. ADJUSTMENT 1 NOTE 1" 51 7/8” 48 1/2”

Upload: others

Post on 11-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: VECTOR™ 50 DIRECT VENT LINEAR GAS APPLIANCE · 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 † 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 Fireplaces, Heating and Cooling:

24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8

Fireplaces, Heating and Cooling: 705-721-1212 • Grills: 705 726-4278 • napoleonproducts.com

VECTOR™ 50 DIRECT VENT LINEAR GAS APPLIANCE

W415-1874 / A / 02.04.19

Specifi cations

Front Options

Framing Dimensions

Model BTUWidth Height Depth

Viewing AreaActual Framing Actual Framing Actual Framing

LV50N-2 36,000 65 5/16 65 13/16 41 3/16 73 19 7/8 20 1/8 52 3/4 X 18 5/8

LV50N2-2 36,000 65 5/16 65 13/16 41 3/16 73 16 3/16 16 3/16 52 3/4 X 18 5/8

single-sided

Ref LV50-2

E 20 1/8” (51.1cm)

F 65 13/16” (167.2cm)

J Optional - Appliance does not need to be elevated above fl oor

*L 73” (185.4cm)

EJ

F

minimum framing

L

note:The LV series requires a minimum enclosure height of 73” measured from the bottom of the appliance. For temperature requirements, this area must be left unobstructed. Some venting confi gurations that require more vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pipes and combustibles.

note:Before framing the appliance, ensure to install the fi restop fi rst.

see-thru

Before framing the appliance, ensure to install the fi restop fi rst as it will not fi t between the studs if installed after framing.

* Minimum enclosure height maybe higher depending on venting confi guration (see minimum distance to combustibles).

Ref LV50-2

E 16 3/16” (41.1cm)

F 65 13/16” (167.2cm)

J Optional - Appliance does not need to be elevated above fl oor

*L 73” (185.4cm)

E F

J

minimum framing

L

note:The LV series requires a minimum enclosure height of 73” measured from the bottom of the appliance. For temperature requirements, this area must be left unobstructed. Some venting confi gurations that require more vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pipes and combustibles.

note:

Product information provided is not complete and is subject to change without notice. Please consult the installation manual for the most up to date installation information.

1 14"

MAX ADJUSTMENT

MIN. PROJECTION FROM FINISHING MATERIAL

38"

53 716

"

47 38

"19 34

"12 15

16"

SLF50K/SS PSB50SS/K

17 916 "

A

3612

"

14 18 "

1 14 "

MAX. ADJUSTMENT

1 NOTE

1"

51 7/8”

48 1/2”

Page 2: VECTOR™ 50 DIRECT VENT LINEAR GAS APPLIANCE · 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 † 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 Fireplaces, Heating and Cooling:

24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8

Fireplaces, Heating and Cooling: 705-721-1212 • Grills: 705 726-4278 • napoleonproducts.com

VECTOR™ 50 DIRECT VENT LINEAR GAS APPLIANCE

Product information provided is not complete and is subject to change without notice. Please consult the installation manual for the most up to date installation information.

Dimensions

Wall Penetration

Appliance LocationCombustible Mantel Clearances

LV50-2

A(Finishing Flange)

52 3/4”(1340mm)

B 65 5/16”(1659mm)

C 69 5/16”(1761mm)

*Finishing flange depth. (The finishing flange defines the perimeter of the fireplace opening. Framing or finishing materials must NEVER encroach inside the finishing flange.)

single-sided

LV50-2

A(Finishing Flange)

52 3/4”(1340mm)

B 65 5/16”(1659mm)

C 69 5/16”(1761mm)

see-thru

single-sided

The LV series requires a minimum enclosure height of 73” (185.4cm) measured from the bottom of the appliance. For temperature requirements, this area must be left unobstructed. Some venting confi gurations that require more vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pipes and combustibles.

note:

Horizontal vent sections: A minimum clearance of 3” (76mm) on the top outside of the enclosure and 2” (51mm) on the sides and bottom outside of the enclosure all around the vent pipe on all horizontal runs to combustibles is required. Horizontal vent sections within enclosures require a minimum clearance of 6”(152mm) at the top of the vent pipe. Vertical vent sections: A minimum of 1” (25mm) all around the vent pipe on all vertical runs to combustibles is required except for clearances in appliances enclo-sures. Vertical vent sections within enclosures require a minimum clearance of 1” (25mm) around the vent pipe.

see-thru

Horizontal vent sections: A minimum clearance of 3” (76mm) on the top outside of the enclosure and 2” (51mm) on the sides and bottom outside of the enclosure all around the vent pipe on all horizontal runs to combustibles is required. Horizontal vent sections within enclosures require a minimum clearance of 6”(152mm) at the top of the vent pipe. Vertical vent sections: A minimum of 1” (25mm) all around the vent pipe on all vertical runs to combustibles is required except for clearances in appliances enclosures. Vertical vent sections within enclosures require a minimum clearance of 1” (25mm) around the vent pipe.

0

MANTEL DEPTH

1 2 3 4 5 6 7 8 9 10112468

1012141618202224

A

Top of finishing flange

Bottom of the appliance

25 11/16" (65.2cm)

2”

Bottom of fi nishing fl ange

Optional hearth extension (no

depth restriction)

MANTEL HEIGHT

MANTEL DEPTH

LV50-2

*E 20 1/8” (51.1cm)

F 65 13/16” (167.2cm)

G 72 1/4” (183.5cm)

H 18 3/16” (46.2cm)

I 102 3/16” (259.5cm)

minimum framing

W415-1874 / A / 02.04.19

g

41 3/16"1046mm

7 1/16"179mm

18 5/8"473mm

3 1/8"80mm

19 7/8"1/2”[12.7mm] 505mm

32 3/4"832mm

39 11/16"1008mm

8 1/16"205mm

8 1/16"205mm

Ø 8"203mm

Ø 5"127mm

A

B

C

SAFETY BARRIER

*

Base of air collar

see-thru

(

41 3/16"1046mm

7 1/16"179mm

18 5/8"473mm

3 1/8"80mm

32 3/4"832mm

39 11/16"1008mm

16 3/16"411mm

8 1/16"205mm

8 1/16"205mm

Ø 8"203mm

Ø 5"127mm

1/2"[12.7mm] 1/2"

[12.7mm]

A

B

C

SAFETY BARRIER

**

Base of air collar

Do not put objects in front of the appliance (minimum distance of 4 feet)

F

G

F

H

I

*E

1” (2.54cm) min.

6” (15.2cm) min.

*Single-sided model illustrated.

3” [76mm] top (outside of enclosure)

2” [51mm] sides / bottom (outside of enclosure)

0” to non-combustible fi nishing such as brick and stone

6” [152mm] minimum(inside enclosure)

0” to bottom of the appliance

0” to side standoffs

1/2” fi nishing fl ange

When passing through a ceiling, use fi restop spacer W500-0028 (not supplied)

When passing through a wall, use fi restop spacer W615-0162 (supplied with W010-4178 fi restop spacer assembly)

0” to back standoffs

1” [25mm] minimum all sides for sections of vertical venting.

3” [76mm] (minimum all sides for sections of horizontal vent-ing) outside of enclosure.

73”minimum

The LV series requires a minimum enclosure height of 73” (185.4cm) measured from the bottom of the ap-pliance. For temperature requirements, this area must be left unobstructed. Some venting confi gurations that require more vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pipes and combustibles.

note:

Shaded components (fi nish framing) must be non-combustible materials.

note:

SAFETY BARRIER

1/2” fi nishing fl ange (4 sides)

3” [76mm] top (out-side of enclosure)

2” [51mm] sides / bottom (outside of enclosure)

0” to non-combustible fi nish-ing such as brick and stone

6” [152mm] minimum(inside enclosure)

0” to side standoffs

0” to base of the appliance

When passing through a ceiling, use fi restop spacer W500-0028 (not supplied)

When passing through a wall, use fi restop spacer W615-0162 (sup-plied with W010-4178 fi restop spacer assembly)

1” [25mm] minimum all sides for sections of vertical venting.

3” [76mm] (minimum all sides for sections of horizontal vent-ing) outside of enclosure.

14”(35.6cm)

min.

Shaded components (fi nish framing) must be non-combustible materials.

note:

73”minimum

*Finishing flange depth. (The finishing flange defines the perimeter of the fireplace opening. Framing or finishing materials must NEVER encroach inside the finishing flange.)

Page 3: VECTOR™ 50 DIRECT VENT LINEAR GAS APPLIANCE · 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 † 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 Fireplaces, Heating and Cooling:

24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8

Fireplaces, Heating and Cooling: 705-721-1212 • Grills: 705 726-4278 • napoleonproducts.com

SÉRIE VECTORMD 50 FOYER À GAZ D’ÉVACUATION DIRECTE

W415-1874 / A / 02.04.19

Spécifi cations

Façades Optionnelle

Dimensions d’ossature

Modèle BTULargeur Hauteur Largeur

Dimensions de VisioneRéel Ossature Réel Ossature Réel Ossature

LV50N-2 36,000 65 5/16 65 13/16 41 3/16 73 19 7/8 20 1/8 52 3/4 X 18 5/8

LV50N2-2 36,000 65 5/16 65 13/16 41 3/16 73 16 3/16 16 3/16 52 3/4 X 18 5/8

Ref LV50-2

E 20 1/8” (51.1cm)

F 65 13/16” (167.2cm)

J Optionnel - l’appareil ne doit pas être élevé au-dessus du plancher

*L 73” (185.4cm)

EJ

F

ossature minimum

L

note:

La série LV requis un minimum hau-teur de l’enceinte de 73” mesuré du bas de l’appareil. Pour les exigences de températures, cet espace doit être dégager. Certains confi gurations requis une enceinte plus large pour fournir les dégagements minimaux entre les conduits d’évacuation et les combustibles.

note:Avant d’encadrer l’appareil, assurez-vous d’installer l’espaceur coupe-feu.

Avant d’encadrer l’appareil, assurez-vous d’installer l’espaceur coupe-feu premier avant qu’il ne soit pas adapté entre les goujouns après l’encadrement.

* L’hauteur minimum de l’enceinte peut être plus grand dépendant du confi guration d’évacuation (voir distance minimum aux matériaux combustibles).

Ref LV50-2

E 16 3/16” (41.1cm)

F 65 13/16” (167.2cm)

J Optionnel - l’appareil ne doit pas être élevé au-dessus du plancher

*L 73” (185.4cm)

E F

Jossature minimum

L

note:

La série LV requis un minimum hau-teur de l’enceinte de 73” mesuré du bas de l’appareil. Pour les exigences de températures, cet espace doit être dégager. Certains confi gurations requis une enceinte plus large pour fournir les dégagements minimaux entre les conduits d’évacuation et les combustibles.

note:

Information du produit fourni n’est pas complet et est sujet de changer sans préavis. Consultez le manuel d’installation pour info-formation d’installation actuel.

1 14"

MAX ADJUSTMENT

MIN. PROJECTION FROM FINISHING MATERIAL

38"

53 716

"

47 38

"34

"12 15

16"

SLF50K/SS PSB50SS/K

17 916 "

A

3612

"

14 18 "

1 14 "

MAX. ADJUSTMENT

1 NOTE

1"

51 7/8”

un seul côté voir à travers

48 1/2”

Page 4: VECTOR™ 50 DIRECT VENT LINEAR GAS APPLIANCE · 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 † 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 Fireplaces, Heating and Cooling:

24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8

Fireplaces, Heating and Cooling: 705-721-1212 • Grills: 705 726-4278 • napoleonproducts.com

SÉRIE VECTORMD 50 FOYER À GAZ D’ÉVACUATION DIRECTE

Information du produit fourni n’est pas complet et est sujet de changer sans préavis. Consultez le manuel d’installation pour info-formation d’installation actuel.

Dimensions

Passage d’un section dans un mur

Location de l’appareilDégagements Combustible de la Tablette

LV50-2

A(Bride de finition)

52 3/4”(1340mm)

B 65 5/16”(1659mm)

C 69 5/16”(1761mm)

* La profondeur de la bride de finition (la bride de finition définit le périmètre de l’ouverture de la cheminée. Les matériaux de charpente ou de finition NE JAMAIS empiété à l’intérieur de la bride de finition.

LV50-2

A(Bride de finition)

52 3/4”(1340mm)

B 65 5/16”(1659mm)

C 69 5/16”(1761mm)

La série LV nécessite une hauteur minimale de 73” (185,4cm) mesurée par le bas de l’appareil. Pour les exigences de températures, l’espace doit être laisser sans obstruction. Certains confi gurations qui requis une course verticale plus large aura besoin d’une enceinte plus large pour fournir les dégagements minimaux entre les conduits d’évacuation et les combustibles.

note:

Sections d’évents horizontales: Un dégagement minimum aux matériaux combustibles de 3” (76mm) au-dessus hors de l’enceinte et 2” (51mm) sur les côtés et au-dessous hors de l’enceinte toute autour du conduit d’évacuation sur toutes les courses horizontales. Les sections d’évacuation horizontales dans les enceintes doit maintenir un dégagement minimaux de 6” (152mm) au-dessus du conduit d’évacuation. Sections d’évents verticales: Un dégagement minimum aux matériaux combustibles de 1” (25mm) est requis toute autour du conduit d’évacuation sur toutes les courses verticales à l’exception des dégagements à l’intérier de l’enceinte de l’appareil. Les courses d’évacuation verticales dans les enceintes requis un dégagement minimum de 1” (25mm) autour du conduit d’évacuation.

Sections d’évents horizontales: Un dégagement minimum aux matériaux combustibles de 3” (76mm) au-dessus hors de l’enceinte et 2” (51mm) sur les côtés et au-dessous hors de l’enceinte toute autour du conduit d’évacuation sur toutes les courses horizontales. Les sections d’évacuation horizontales dans les enceintes doit maintenir un dégagement minimaux de 6” (152mm) au-dessus du conduit d’évacuation. Sections d’évents verticales: Un dégagement minimum aux matériaux combustibles de 1” (25mm) est requis toute autour du conduit d’évacuation sur toutes les courses verticales à l’exception des dégagements à l’intérier de l’enceinte de l’appareil. Les courses d’évacuation verticales dans les enceintes requis un dégagement minimum de 1” (25mm) autour du conduit d’évacuation.

0

MANTEL DEPTH

1 2 3 4 5 6 7 8 9 10112468

1012141618202224

A

Top of finishing flange

Bottom of the appliance

25 11/16" (65.2cm)

2”

Bottom of fi nishing fl ange

Optional hearth extension (no

depth restriction)

MANTEL HEIGHT

MANTEL DEPTH

LV50-2

*E 20 1/8” (51.1cm)

F 65 13/16” (167.2cm)

G 72 1/4” (183.5cm)

H 18 3/16” (46.2cm)

I 102 3/16” (259.5cm)

W415-1874 / A / 02.04.19

41 3/16"1046mm

7 1/16"179mm

18 5/8"473mm

3 1/8"80mm

19 7/8"1/2”[12.7mm] 505mm

32 3/4"832mm

39 11/16"1008mm

8 1/16"205mm

8 1/16"205mm

Ø 8"203mm

Ø 5"127mm

A

B

C

Barrière de protection

*

Base du collet d’air

41 3/16"1046mm

7 1/16"179mm

18 5/8"473mm

3 1/8"80mm

32 3/4"832mm

39 11/16"1008mm

16 3/16"411mm

8 1/16"205mm

8 1/16"205mm

Ø 8"203mm

Ø 5"127mm

1/2"[12.7mm] 1/2"

[12.7mm]

A

B

C

Barrière de protection

**

Base du collet d’air

Do not put objects in front of the appliance (minimum distance of 4 feet)

F

G

F

H

I

*E

1” (2.54cm) min.

6” (15.2cm) min.

*Modèle d’un seul côté illustré.

3” [76mm] haut (hors de l’enceinte)

2” [51mm] côtés / bas (hors de l’enceinte)

0” aux fi nitions incom-bustibles telles que le brique et la pierre

6” [152mm] minimum(dedans l’enceinte)

0” vers le bas de l’appareil

0” aux contraintes latérales

1/2” bride de fi nition

Lorsque vous passez par un mur, utilisez l’espaceur coupe-feu W615-0162 (fourni avec l’assemblage d’espaceur coupe-feu W010-4178

0” aux contraintes arrière

3” [76mm] (minimum toutes les côtés pour les sections d’évacuation horizontales) hors de l’enceinte.

73”minimum

La série LV nécessite une hauteur minimale de 73” (185,4cm) mesurée par le bas de l’appareil. Pour les exigences de températures, l’espace doit être laisser sans obstruction. Certains confi gurations qui requis une course verticale plus large aura besoin d’une enceinte plus large pour fournir les dégagements minimaux entre les conduits d’évacuation et les combustibles.

note:

Les composants ombragés (encadre-ment de fi nition) doivent être de matériaux incombustibles.

note:

Barrière de protection1/2” bride de fi nition

3” [76mm] haut (hors de l’enceinte)

2” [51mm] côtés / bas (hors de l’enceinte)

0” aux fi nitions incom-bustibles telles que le brique et la pierre

6” [152mm] minimum(dedans l’enceinte)

0” aux contraint-es latérales

0” vers le bas de l’appareil

Lorsque vous passez par un mur, utilisez l’espaceur coupe-feu W615-0162 (fourni avec l’assemblage d’espaceur coupe-feu W010-4178

3” [76mm] (minimum toutes les côtés pour les sections d’évacuation horizontales) hors de l’enceinte.

14”(35.6cm)

min.

Les composants ombragés (encadre-ment de fi nition) doivent être de matériaux incombustibles.

note:

73”minimum

un seul côté voir à travers

un seul côté voir à travers

En passant par un pla-fond, utilisez l’espaceur coupe-feu W500-0028 (non fourni)

1” [25mm] minimum tous les côtés pour les sections d’évacuation verticale.

En passant par un plafond, uti-lisez l’espaceur coupe-feu W500-0028 (non fourni)

1” [25mm] minimum tous les côtés pour les sections d’évacuation verticale.

ossature minimum

Ne placez pas d’objets devant l’appareil (distance minimale de 4 pi.)

Base de protec-tion optionnelle

MANTEL HEIGHT

MANTEL DEPTH

MANTEL HEIGHT

MANTEL DEPTH

Hauteur de tablette

Profondeur de tablette

Hauteur de tablette

Profondeur de tablette