vds curtain wall elevation - arcat, inc. · pdf file6 clip joint and corner detail 7 1 2 4...

17
VDS CURTAIN WALL ELEVATION 1 2 10 2 3 4 5 5 4 8 9 9 8 OPP. HND OPP. HND SPANDREL FLOOR SLAB VDS CURTAIN WALL SYSTEM ELEVATION 2108 B Street N.W., Suite 110 Auburn, WA 98001 USA TEL: 888 - 803 - 9533 FAX: 253 - 333 - 5166 ww.vetrotechusa.com 1 / 17

Upload: ledieu

Post on 15-Feb-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

VDS CURTAIN WALL ELEVATION

1

2

10

2

3

4554

8998

OPP.HND

OPP.HND

SPANDREL

FLOORSLAB

VDS CURTAIN WALLSYSTEM ELEVATION

2108 B Street N.W., Suite 110Auburn, WA 98001 USATEL: 888 - 803 - 9533FAX: 253 - 333 - 5166ww.vetrotechusa.com

1 / 17

6

CLIP JOINT ANDCORNER DETAIL

7

1

2

4OPP.HND

5

3

VDS CURTAIN WALLWALL ELEVATION

2108 B Street N.W., Suite 110Auburn, WA 98001 USATEL: 888 - 803 - 9533FAX: 253 - 333 - 5166ww.vetrotechusa.com

2 / 17

Maximum Dimensions May Apply

Max

imum

Dim

ensi

ons

May

App

ly

Maximum Dimensions May Apply

Max

imum

Dim

ensi

ons

May

App

ly

NOTE:Refer to current datasheet for maximumsizes of exposedglass.

VDS 60/120 WALL ELEVATIONWITH 60/90 MIN. SINGLE DOOR

VDS 60/120 WALL ELEVATIONWITH 60/90 MIN. PAIR OF DOORS

15

1

2 16 5 4

1615

1

2

3

3

16 5 4

16

15

15

Maximum DimensionsMay Apply

Max

imum

Dim

ensi

ons

May

App

ly

Maximum DimensionsMay Apply

Max

imum

Dim

ensi

ons

May

App

ly

11

11

11

13

14 13

14

11

Pair of Doors with Sidelite and Transom

Single Door with Sidelite and TransomStand AloneSingle Door

Stand AlonePair of Doors

VDS CURTAN WALLSYSTEM W/ VDS 60/90 DOOR

ELEVATIONS

2108 B Street N.W., Suite 110Auburn, WA 98001 USATEL: 888 - 803 - 9533FAX: 253 - 333 - 5166ww.vetrotechusa.com

3 / 17

VARIES

238"

[60m

m]

FRA

ME

HE

IGH

T

FRA

ME

R.O

.1 2"

[13m

m]

H

A

B

I

K

J

O

L

N

F

C

G

P

N

HEAD DETAIL1

A VDS STEEL CURTAIN WALLHORIZONTAL MEMBER.

B VDS STEEL CURTAIN WALL VERTICALMEMBER.

C PRESSURE PLATE LOCKING SCREW.

D SETTING BLOCK (NOT BYVETROTECH).

E SETTING BLOCK SHELF.

F PRESSURE PLATES.

G HORIZONTAL COVER CAP.

H SGG FIRE RATED GLAZING. SEEGLAZING OPTIONS FOR MOREINFORMATION.

I HORIZONTAL WEATHER STRIPPING.

J SILL & HEAD PLATE WITH SHEAR LUG@ VERTICAL MULLION.

K HARDWOOD BLOCK.

L ANCHORS (NOT BY VETROTECH).

M SHIM AS NECESSARY (NOT BYVETROTECH).

N FIRE STOP & SMOKE SEAL (NOT BYVETROTECH).

O FIRE RESISTANT LOOSE INSULATION(NOT BY VETROTECH).

P FINISH SEALANT (NOT BYVETROTECH).

Q. CLAMPING FOOT.

D.L

.O.

3 916" - 5

78"

[90mm - 150mm]

238"

[60m

m]

VARIES

D

E

F

C

G

H

B

A

HORIZONTAL MULLION DETAIL2

SILL DETAIL3

VARIES

238"

[60m

m]

FRA

ME

HE

IGH

T

FRA

ME

R.O

.

1 2" [1

3mm

]

H

A

B

I

K

J

O

L

M

D

E

F

C

G

P

N

D.L

.O.

3 916" - 5

78"

[90mm - 150mm]

D.L

.O.

D.L

.O.FR

AM

E H

EIG

HT

FRA

ME

R.O

.

D

E

3 916" - 57

8"[90mm - 150mm]

Q

Q

I

Q

INTERIOR APPLICATION SHOWN

INTERIOR APPLICATION SHOWN

INTERIOR APPLICATION SHOWN

NOTE:ACTUAL ANCHORING MAY VARY PERPROJECT REQUIREMENTS. DRAWINGFOR REFERENCE ONLY.

KEY NOTES

VDS CURTAIN WALLSYSTEM DETAILS

2108 B Street N.W., Suite 110Auburn, WA 98001 USATEL: 888 - 803 - 9533FAX: 253 - 333 - 5166ww.vetrotechusa.com

4 / 17

238"

[60mm]

VA

RIE

S

F

G

C

A

B

I

H

VA

RIE

S

238"

[60mm]

FRAME WIDTH1

2" [13mm]

J

H

F

C

D.L.O.

VERTICAL MULLION DETAIL5

JAMB DETAIL4

N

O

I

N

P

G

K

B

A

FRAME R.O.

238"

[60mm]D.L.O. D.L.O.

FRAME WIDTH

FRAME R.O.

A VDS STEEL CURTAIN WALLHORIZONTAL MEMBER.

B VDS STEEL CURTAIN WALL VERTICALMEMBER.

C PRESSURE PLATE LOCKING SCREW.

D SETTING BLOCK (NOT BYVETROTECH).

E SETTING BLOCK SHELF.

F PRESSURE PLATES.

G VERTICAL COVER CAP.

H SGG FIRE RATED GLAZING. SEEGLAZING OPTIONS FOR MOREINFORMATION.

I VERTICAL WEATHER STRIPPING.

J SILL& HEAD PLATE WITH SHEAR LUG@ VERTICAL MULLION.

K HARDWOOD BLOCK.

L ANCHORS (NOT BY VETROTECH).

M SHIM AS NECESSARY (NOT BYVETROTECH).

N FIRE STOP & SMOKE SEAL (NOT BYVETROTECH).

O FIRE RESISTANT LOOSE INSULATION(NOT BY VETROTECH).

P FINISH SEALANT (NOT BYVETROTECH).

Q. CLAMPING FOOT.

INTERIOR APPLICATION SHOWN

P

Q

J

Q

39 16

" -

57 8"

[90m

m -

150m

m]

39 16

" -

57 8"

[90m

m -

150m

m]

INTERIOR APPLICATION SHOWN

L

NOTE:ACTUAL ANCHORING MAY VARY PERPROJECT REQUIREMENTS. DRAWINGFOR REFERENCE ONLY.

L

KEY NOTES

VDS CURTAIN WALL SYSTEM DETAILS

2108 B Street N.W., Suite 110Auburn, WA 98001 USATEL: 888 - 803 - 9533FAX: 253 - 333 - 5166ww.vetrotechusa.com

5 / 17

238"

[60mm]FRAME WIDTH

238"

[60m

m]

238"

[60mm]

FRA

ME

WID

TH

TUBE STL. (A36)

SGG FIRE RATEDGLAZING.

ALIGNTYP.

VDS STEEL CURTAINWALL VERTICALMEMBER.

VARIES

23 8"

[60m

m]FRAME W

IDTH

VARIES

VARIES

16 GA. STL.ANCHORING STRIP,PLUG WELD TO TUBESTEEL @ 20" O.C.

16 GA. STL. 90 CORNER

1/4" STEEL (A36)PLATE (TYP.)BELOW

CALCIUM SILICATEINSULATION

FRAME WIDTH

516"

[8mm]

5 16"

[8m

m]

5 16"

[8mm]

516"

[8mm]

135 "

16 GA. STL. 45 CORNER

1/4" STEEL (A36) PLATE(TYP.) BELOW

16 GA. STL. ANCHORINGSTRIP @ 20" O.C.

45 "

16 GA. STL. CONTINUOUSPANEL

VA

RIE

SV

.I.F.

VARIES V.I.F.

D.L.O.

D.L.O.

90 CORNER DETAIL6

45 CORNER DETAIL7

VA

RIE

S

VARIES

VA

RIE

S

VARIES

VA

RIE

S

3 916" - 5

78"

[90mm - 150mm]

39 16

" - 5

7 8"[9

0mm

- 15

0mm

]

39 16

" - 5

7 8"[9

0mm

- 15

0mm

]

3 916 " - 5 78 "

[90mm - 150mm]

D.L

.O.

D.L.O.

EXTERIOR APPLICATIONSHOWN

EXTERIOR APPLICATIONSHOWN

ANCHOR BOLT (NOT BYVETROTECH) TYPICAL

NOTE:ACTUAL ANCHORING MAY VARY PERPROJECT REQUIREMENTS. DRAWINGFOR REFERENCE ONLY.

ANCHOR BOLT (NOTBY VETROTECH)TYPICAL

VDS CURTAIN WALL SYSTEM CORNER DETAILS

2108 B Street N.W., Suite 110Auburn, WA 98001 USATEL: 888 - 803 - 9533FAX: 253 - 333 - 5166ww.vetrotechusa.com

6 / 17

VARIES

516"

238"

[60mm]

1 916"

VA

RIE

S3

9 16" -

57 8"

[90m

m -

150m

m]

VERTICAL MULLIONSECTION AT FLOOR SLAB

8

D.L.O.

A VDS STEEL CURTAIN WALLHORIZONTAL MEMBER.

B VDS STEEL CURTAIN WALL VERTICALMEMBER.

C PRESSURE PLATE LOCKING SCREW.

D SETTING BLOCK (NOT BYVETROTECH).

E SETTING BLOCK SHELF.

F PRESSURE PLATES.

G VERTICAL COVER CAP.

H SGG FIRE RATED GLAZING. SEEGLAZING OPTIONS FOR MOREINFORMATION.

I VERTICAL WEATHER STRIPPING.

J FRAME SILL/HEAD PLATE @ VERTICALMULLION.

K HARDWOOD BLOCK.

L ANCHORING ASSEMBLY (NOT BYVETROTECH).

M ANCHOR BOLT (NOT BY VETROTECH).

N FIRE STOP & SMOKE SEAL (NOT BYVETROTECH).

O FIRE RESISTANT LOOSE INSULATION(NOT BY VETROTECH).

P FINISH SEALANT (NOT BYVETROTECH).

Q. CLAMPING FOOT.

R. FIELD WELD.

B

C

F

G

I

K

P

N

H

O

L

FRAME WIDTH1

2" [13mm]

FRAME R.O.

Q

EXTERIOR APPLICATION SHOWN

P

N

M

NOTE:ACTUAL ANCHORING MAY VARY PERPROJECT REQUIREMENTS. DRAWINGFOR REFERENCE ONLY.

R

KEY NOTES

VDS CURTAIN WALL SYSTEM INTERMEDIATE

ANCHORING DETAIL

2108 B Street N.W., Suite 110Auburn, WA 98001 USATEL: 888 - 803 - 9533FAX: 253 - 333 - 5166ww.vetrotechusa.com

7 / 17

516"

1"

1 916"

VARIES

VA

RIE

S3

9 16" -

57 8"

[90m

m -

150m

m]

238"

[60mm]D.L.O.

VERTICAL MULLIONSECTION AT FLOOR SLAB

9

D.L.O.

B

C

F

G

I

L

A VDS STEEL CURTAIN WALLHORIZONTAL MEMBER.

B VDS STEEL CURTAIN WALL VERTICALMEMBER.

C PRESSURE PLATE LOCKING SCREW.

D SETTING BLOCK (NOT BYVETROTECH).

E SETTING BLOCK SHELF.

F PRESSURE PLATES.

G VERTICAL COVER CAP.

H SGG FIRE RATED GLAZING. SEEGLAZING OPTIONS FOR MOREINFORMATION.

I VERTICAL WEATHER STRIPPING.

J FRAME SILL/HEAD PLATE @ VERTICALMULLION.

K HARDWOOD BLOCK.

L ANCHOR ASSEMBLY (NOT BYVETROTECH).

M ANCHOR BOLT (NOT BY VETROTECH).

N FIRE STOP & SMOKE SEAL (NOT BYVETROTECH).

O FIRE RESISTANT LOOSE INSULATION(VETROTECH).

P FINISH SEALANT (NOT BYVETROTECH).

Q. CLAMPING FOOT.

R. FIELD WELD.

FRAME WIDTH

FRAME R.O.

H

Q

EXTERIOR APPLICATION SHOWN

M

NOTE:ACTUAL ANCHORING MAY VARY PERPROJECT REQUIREMENTS. DRAWINGFOR REFERENCE ONLY.

R

KEY NOTESSOME CALLOUTS MAY NOTAPPLY TO SPECIFIC DETAIL

VDS CURTAIN WALL SYSTEM INTERMEDIATE

ANCHORING DETAIL

2108 B Street N.W., Suite 110Auburn, WA 98001 USATEL: 888 - 803 - 9533FAX: 253 - 333 - 5166ww.vetrotechusa.com

8 / 17

VARIES

VARIES 1 916"

4"6"

134" 111

16"

212"

214"

5"

112"

214"

1"112"

VARIES 3 916" - 5

78"

[90mm - 150mm]

238"

[60m

m]

D.L

.O.

D.L

.O.

WIN

DO

W F

RA

ME

WIN

DO

W R

.O.

238"

[60m

m]

D.L

.O.

A VDS STEEL CURTAIN WALLHORIZONTAL MEMBER.

B VDS STEEL CURTAIN WALLVERTICAL MEMBER.

C PRESSURE PLATE LOCKINGSCREW.

D SETTING BLOCK (NOT BYVETROTECH).

E SETTING BLOCK SHELF.

F PRESSURE PLATES WITHWEEP HOLES.

G HORIZONTAL COVER CAP WITHWEEP HOLES.

H SGG FIRE RATED GLAZING.SEE GLAZING OPTIONS FORMORE INFORMATION.

I HORIZONTAL WEATHERSTRIPPING WITH FIN.

J FIRE SAFING AND INSULATION(NOT BY VETROTECH).

K HARDWOOD BLOCK.

L ANCHOR ASSEMBLY (NOT BYVETROTECH).

M ANCHOR BOLTS (NOT BYVETROTECH).

N FIRE STOP & SMOKE SEAL(NOT BY VETROTECH).

O FIRE RESISTANT LOOSEINSULATION (NOT BYVETROTECH).

P FINISH SEALANT (NOT BYVETROTECH).

Q. CLAMPING FOOT.

R. FIELD WELD.

HORIZONTAL SECTION ATFLOOR SLAB10

EXTERIOR APPLICATION SHOWN

D

E

F

C

G

H

A

I

Q

B

J

LM

NOTE:ACTUAL ANCHORING MAY VARY PERPROJECT REQUIREMENTS. DRAWINGFOR REFERENCE ONLY.

R

KEY NOTES

VDS CURTAIN WALL SYSTEM INTERMEDIATE

ANCHORING DETAIL

2108 B Street N.W., Suite 110Auburn, WA 98001 USATEL: 888 - 803 - 9533FAX: 253 - 333 - 5166ww.vetrotechusa.com

9 / 17

DOOR OPENING

3916"

[90mm]

14"

[6mm]

38"

[10mm]

11516"

[50mm]23

8" [60mm]

234"

[70mm]

DOOR JAMB DETAIL11

FRAME WIDTH

ROUGH OPENING

D.L.O.

12"

[13mm]

2916

" [6

5mm

]

DOOR OPENING

3916"

[90mm]

38"

[10mm]

11516"

[50mm]23

8" [60mm]

DOOR JAMB DETAIL WITH SIDELITE12

FRAME DIMENSION

D.L.O.

2916

" [6

5mm

]

D.L.O.

VA

RIE

S3

9 16" -

57 8"

[90m

m -

150m

m]

R

P

N

B

14"

[6mm]

11516"

[50mm]

1316"

[20mm]

ROUGH OPENING

A VDS STEEL CURTAIN WALLHORIZONTAL MEMBER.

B VDS STEEL CURTAIN WALL VERTICALMEMBER.

C PRESSURE PLATE LOCKING SCREW.

D SETTING BLOCK (NOT BYVETROTECH).

E SETTING BLOCK SHELF.

F PRESSURE PLATES.

G VERTICAL COVER CAP.

H SGG FIRE RATED GLAZING. SEEGLAZING OPTIONS FOR MOREINFORMATION.

I VERTICAL WEATHER STRIPPING.

J SILL & HEAD PLATE WITH SHEAR LUG@ VERTICAL MULLION.

K HARDWOOD BLOCK.

L ANCHOR (NOT BY VETROTECH).

M SHIM AS NECESSARY (NOT BYVETROTECH).

N FIRE STOP & SMOKE SEAL (NOT BYVETROTECH).

O FIRE RESISTANT LOOSE INSULATION(NOT BY VETROTECH).

P FINISH SEALANT (NOT BYVETROTECH).

Q. CLAMPING FOOT

R. HINGE PER HARDWARE SCHEDULE.

S. VDS 60/90 DOOR.

T. DOOR ASSEMBLY FASTENER TOCURTAIN WALL.

INTERIOR APPLICATION SHOWN

INTERIOR APPLICATION SHOWN

VA

RIE

S3

9 16" -

57 8"

[90m

m -

150m

m]

J

Q

O

F

C

G

H

S

P

N

O

P

N

OS

H

R

J

B

Q

H

F

C

G

I

I

K

L

K

A

L

NOTE:ACTUAL ANCHORING MAY VARY PERPROJECT REQUIREMENTS. DRAWINGFOR REFERENCE ONLY.

KEY NOTES

T

T

VDS CURTAIN WALL WITHVDS 60/90 DOOR DETAILS

2108 B Street N.W., Suite 110Auburn, WA 98001 USATEL: 888 - 803 - 9533FAX: 253 - 333 - 5166ww.vetrotechusa.com

10 / 17

234"

[70mm]

112"

[38mm]23

4"[70mm]

916"

[14mm] 38"

[10mm]

38"

[10mm]

D.L.O.D.L.O.

DOOR OPENING

FRAME DIMENSION

2916

" [6

5mm

]

ACTIVE / ACTIVE DOOR MEETING STILES13

ACTIVE / INACTIVE DOOR MEETING STILES14

2916

" [6

5mm

]

7" [178mm]

PULL(HANDLE)

SIDE

PUSH(EXIT DEVICE)

SIDE

ROUGH OPENING

D.L.O.D.L.O.

DOOR OPENING

FRAME DIMENSION

578"

[150mm]

ROUGH OPENING

PULL(HANDLE)

SIDE

PUSH(EXIT DEVICE)

SIDE

INTERIOR APPLICATION SHOWN

INTERIOR APPLICATION SHOWN

VDS 60/90DOOR DETAILS

2108 B Street N.W., Suite 110Auburn, WA 98001 USATEL: 888 - 803 - 9533FAX: 253 - 333 - 5166ww.vetrotechusa.com

11 / 17

38"

[10m

m]

10"

[254

mm

]

DO

OR

OP

EN

ING

2916"

[65mm]

38"

[10m

m]

115 16

" [5

0mm

]

1 4" [6

mm

]23

8" [6

0mm

]

VARIES

C

F

G

I

PULL(HANDLE)

SIDE

PUSH(EXIT DEVICE)

SIDE

P

A

DOOR WITH HEADER AND BOTTOM RAIL15

FRA

ME

DIM

EN

SIO

N

3 916" - 57

8"[90mm - 150mm]

A VDS STEEL CURTAIN WALLHORIZONTAL MEMBER.

B VDS STEEL CURTAIN WALL VERTICALMEMBER.

C PRESSURE PLATE LOCKING SCREW.

D SETTING BLOCK (NOT BYVETROTECH).

E SETTING BLOCK SHELF.

F PRESSURE PLATES.

G HORIZONTAL COVER CAP.

H SGG FIRE RATED GLAZING. SEEGLAZING OPTIONS FOR MOREINFORMATION.

I HORIZONTAL WEATHER STRIPPING.

J FRAME BASE PLATE @ VERTICAL.

K HARDWOOD BLOCK.

L ANCHOR (NOT BY VETROTECH).

M SHIM AS NECESSARY (NOT BYVETROTECH).

N FIRE STOP & SMOKE SEAL (NOT BYVETROTECH).

O FIRE RESISTANT LOOSE INSULATION(NOT BY VETROTECH).

P FINISH SEALANT (NOT BYVETROTECH).

Q. CLAMPING FOOT.

R. HINGE PER HARDWARE SCHEDULE.

S. VDS 60/90 DOOR.

T. DOOR ASSEMBLY FASTENER TOCURTAIN WALL.

KE

Q

K

N

O

S

H

INTERIOR APPLICATION SHOWN

S

KEY NOTES

1 2" [1

3mm

]

OP

N

J

O

L

T

VDS CURTAIN WALL WITHVDS 60/90 DOORS

2108 B Street N.W., Suite 110Auburn, WA 98001 USATEL: 888 - 803 - 9533FAX: 253 - 333 - 5166ww.vetrotechusa.com

12 / 17

38"

[10m

m]

10"

[254

mm

]

2916"

[65mm]

38"

[10m

m]

115 16

" [5

0mm

]

1 4" [6

mm

]23

8" [6

0mm

] C

D

E

F

G

A

I

K

H

PULL(HANDLE)

SIDE

PUSH(EXIT DEVICE)

SIDE

P

DO

OR

OP

EN

ING

FRA

ME

DIM

EN

SIO

N

VARIES 3 916" - 57

8"[90mm - 150mm]

DOOR WITH TRANSOM AND BOTTOM RAIL16

A VDS STEEL CURTAIN WALLHORIZONTAL MEMBER.

B VDS STEEL CURTAIN WALL VERTICALMEMBER.

C PRESSURE PLATE LOCKING SCREW.

D SETTING BLOCK (NOT BYVETROTECH).

E SETTING BLOCK SHELF.

F PRESSURE PLATES.

G HORIZONTAL COVER CAP.

H SGG FIRE RATED GLAZING. SEEGLAZING OPTIONS FOR MOREINFORMATION.

I HORIZONTAL WEATHER STRIPPING.

J FRAME BASE PLATE @ VERTICAL.

K HARDWOOD BLOCK.

L ANCHOR (NOT BY VETROTECH).

M SHIM AS NECESSARY (BY NOT BYVETROTECH).

N FIRE STOP & SMOKE SEAL (NOT BYVETROTECH).

O FIRE RESISTANT LOOSE INSULATION(NOT BY VETROTECH).

P FINISH SEALANT (NOT BYVETROTECH).

Q. CLAMPING FOOT.

R. HINGE PER HARDWARE SCHEDULE.

S. VDS 60/90 DOOR.

T. DOOR ASSEMBLY FASTENER TOCURTAIN WALL.

B

N

O

INTERIOR APPLICATION SHOWN

S

H

Q

KEY NOTES

T

VDS CURTAIN WALL WITHVDS 60/90 DOORS

2108 B Street N.W., Suite 110Auburn, WA 98001 USATEL: 888 - 803 - 9533FAX: 253 - 333 - 5166ww.vetrotechusa.com

13 / 17

VA

RIE

S

12"

[12mm]D.L.O.

GLASS DIM.

34"

[19m

m]

115 16

" [5

0mm

]

1/16" [1.8 mm]

215 16

" [7

5mm

]

1/16" [1.8 mm]

76.851

58"

[16m

m]

76.852

76.853

3916

" [9

0mm

]

1/16" [2 mm]

1/16" [1.8 mm]

76.854

4516

" [1

10m

m]

1/16" [2 mm]

76.855

518"

[130

mm

]

578"

[150

mm

]13

4" [45mm]

1/8" [3 mm]

76.856

PRESSURE PLATELOCKING SCREW

WEATHER STRIPPING

PRESSURE PLATE

CLAMPING FOOT

TEMPERATURE RISE GLAZING See Glazing options for more

information.

SPACER

AVAILABLE VDSCURTAIN WALL PROFILES

171-3/4" (45 mm) WIDE PROFILES

FACING PROFILE Aluminum 6060 T66, cold pressed Stainless Steel 1.4301 ground with grain 220-240, with protective adhesive

film

VDS CURTAIN WALL45 mm PROFILE OPTIONS

2108 B Street N.W., Suite 110Auburn, WA 98001 USATEL: 888 - 803 - 9533FAX: 253 - 333 - 5166ww.vetrotechusa.com

14 / 17

3916

" [9

0mm

]

4516

" [1

10m

m]51

8" [1

30m

m]

VA

RIE

S

115 16

" [5

0mm

]

AVAILABLE VDSCURTAIN WALL PROFILES

18

238"

[60mm]

PRESSURE PLATELOCKING SCREW

WEATHER STRIPPING

PRESSURE PLATE

FACING PROFILE Aluminum 6060 T66, cold pressed Stainless Steel 1.4301 ground with grain 220-240, with protective

adhesive film.

578"

[150

mm

]

CLAMPING FOOT

TEMPERATURE RISE GLAZING See Glazing options for more

information.

316"

[4.5 mm]

1/16" [2 mm]

1/16" [2 mm]

1/16" [1.8 mm]

1/16" [1.8 mm]

1316"

[20mm]D.L.O.

GLASS DIM.

76.861

76.863

76.864

76.865

76.866

SPACER

76.862

215 16

" [7

5mm

]

1/16" [1.8 mm]

58"

[16m

m]

34"

[19m

m]

2-3/8" (60 mm) WIDE PROFILES

VDS CURTAIN WALL60 mm PROFILE OPTIONS

2108 B Street N.W., Suite 110Auburn, WA 98001 USATEL: 888 - 803 - 9533FAX: 253 - 333 - 5166ww.vetrotechusa.com

15 / 17

CONTRAFLAM 60A B

CONTRAFLAM 120C D

238"

[61m

m]

1" [2

5mm

]

VA

RIE

S

278"

[73m

m]

112"

[38m

m]

VA

RIE

S

215 16

" [7

5mm

]

1916

" [4

0mm

]

VA

RIE

S

311 16

" [9

4mm

]

2516

" [5

9mm

]

VA

RIE

S

60 MIN. INTERIOR TEMPERATURERISE APPLICATION

CONTRAFLAM 60 IGUWITH 1/4" AIR SPACE

CONTRAFLAM 120 IGUWITH 1/2" AIR SPACE

NOTE:Refer to current data sheet formaximum sizes of exposed glass.

120 MIN. INTERIOR TEMPERATURERISE APPLICATION

60 MIN. EXTERIORTEMPERATURE RISEAPPLICATION

120 MIN. EXTERIORTEMPERATURE RISEAPPLICATION

VDS CURTAIN WALLSYSTEM GLAZING OPTIONS

2108 B Street N.W., Suite 110Auburn, WA 98001 USATEL: 888 - 803 - 9533FAX: 253 - 333 - 5166ww.vetrotechusa.com

16 / 17

ASSEMBLY

KERALITE ULTRAE F

218"

[54m

m]

34"

[18m

m]V

AR

IES

258"

[67m

m]

114"

[31m

m]

VA

RIE

S

KERALITE ULTRA IGUWITH 1/4" AIR SPACE

NOTE:Refer to current data sheet formaximum sizes of exposed glass.

45 MIN. INTERIORNON-TEMPERATURE RISEAPPLICATION

45 MIN. EXTERIORNON-TEMPERATURE RISEAPPLICATION

SWISSFLAM 45G H

218"

[54m

m]

34"

[18m

m]V

AR

IES

258"

[67m

m]

114"

[32m

m]

VA

RIE

S

SWISSFLAM 45 IGUWITH 1/4" AIR SPACE

45 MIN. INTERIORNON-TEMPERATURE RISEAPPLICATION

45 MIN. EXTERIORNON-TEMPERATURE RISEAPPLICATION

VDS CURTAIN WALLSYSTEM GLAZING OPTIONS

2108 B Street N.W., Suite 110Auburn, WA 98001 USATEL: 888 - 803 - 9533FAX: 253 - 333 - 5166ww.vetrotechusa.com

17 / 17