vascular tunneling systems - scanlan international€¦ · tunnelers tunneler sheaths and bullet...

3
Vascular Tunneling Systems

Upload: trinhminh

Post on 04-Sep-2018

230 views

Category:

Documents


0 download

TRANSCRIPT

VascularTunneling Systems

Tunnelers Tunneler Sheaths and Bullet Tips

InteriorDiameters

(mm)For Grafts

Up To (mm)

Vascular Tunneler

20.5" / 52 cm

9009-24

20.5" / 52 cm

9009-1612 10

20.5" / 52 cm

9009-189.5 8

A/V AccessTunneler

12" / 30.5 cm

9009-14

12" / 30.5 cm

9009-209 8

12" / 30.5 cm

9009-227 6

A/V Access Tunneler

Partial Curve 12" / 30.5 cm

9009-13

12" / 30.5 cm

9009-209 8

12" / 30.5 cm

9009-227 6

A/V Access Tunneler Full Curve

12" / 30.5 cm

9009-15

12" / 30.5 cm

9009-219 8

12" / 30.5 cm

9009-237 6

The SCANLAN® Vascular Tunneling System combines high quality grasping forceps with single-use tunneler sheaths for fast, accurate, atraumatic implantation of subcutaneous grafts.

The grasping forceps features include . . . • Achoiceofthreestyles:Vasculartunnelergraspingforceps(201/2"/52cm),A/VAccesstunneler graspingforceps(12"/30.5cm),andFullCurveA/VAccesstunnelergraspingforceps(12"/30.5cm)

• Eachstylewillaccommodatetwosheathdiameters(largeorsmall)• Aknurledhandleforpositivecontrol• Ahandleindicatortoverifytunnelercurvedirection• Stainlesssteelconstruction,offeringstrengthandlonglife,aswellasquick,reliable,atraumaticgraftplacement• Speciallydesigned,stainlesssteelsterilization/storagecasealsoavailable

Reinforcedgraftsmayrequirelargersheaths.

The single-use sheath features include . . .• Twosheathdiameters(LargeandSmall)designedtofiteachforcepsstyle• Eachsheathdiameteravailableintwolengths(201/2"/52cmand12"/30.5cm)

toaccommodatevariousgrafts• Allowsatraumatictunnelingandplacementofgraftswithoutkinking,twisting,

stretching, or pulling• Smoothpolymersheathsandbullettipsoffernearfrictionlessgraft

placement, essential for many new graft surfaces• Minimalsheathdiametersavoidexcessivetissuedisruption• Color-codingprovideseasylengthanddiameteridentification• Radiopaqueandlatex-safe

Tunneler Grasping Forceps Single-Use Tunneler Sheaths

9009-10 Vascular Tunneler and A/V Access Tunneler Grasping Forceps SetSetincludesoneVascularTunneler20.5"(52cm),one A/VAccessTunneler12"(30.5cm),andonetunnelerstorage/ sterilizationtray3.5"x26"x1.5"(8.9cmx66cmx3.8cm).(Set does not include tunneler sheaths.)

9009-12 Vascular Tunneler Grasping Forceps Set SetincludesoneVascularTunneler20.5"(52cm),andone tunnelerstorage/sterilizationtray3.5"x26"x1.5" (8.9cmx66cmx3.8cm). (Set does not include tunneler sheaths.)

9009-26 Tunneler Storage / Sterilization Tray 3.5"x26"x1.5"(8.9cmx66cmx3.8cm).AccommodatesoneVascularandoneA/VAccessTunnelerGraspingForceps(accommodates only the 9009-24 and 9009-14).

Vascular Tunneler Sets

Instructions For Use

Fully insert the bullet tip into the sheath until there is no gap betweentipandsheath.

Open the grasping forceps, insertthegraftandclosethegraspingforceps.(Thegraftmaybesuturedtotheforcepsifpreferred.)

Slidetheassembledsheathandbullettipontothetunnelinginstrumentuntilitisseatedonthehandle.

Carefully secure the tunneling sheath,andgentlypullthegraspingforcepshandledrawingthegraftintothesheath.

Position Tunneler.ApplyForcealongthedirectionofthetunneler.Avoidreversingthe tunneler.

Oncethegraftisentirelyinsidethe sheath, release it from the grasping forceps.

Once the tunneler is in place, remove the bullet tip from the sheathexposingthegraspingforceps.

Securetheendofthegraftandgentlyremovethetunnelersheath. The graft is now in position.

Note:Followstandardsurgicaltechniquetocreateentranceandexitincisionsforthetunneler.

MK-B-TNLR Rev. A© 2010 Scanlan International, Inc.

ONE SCANLAN PLAZA • SAINT PAUL, MINNESOTA 55107 • U.S.A.800-328-9458 • 651-298-0997 • FAX 651-298-0018 • www.scanlaninternational.com