validation measurement campaigns
TRANSCRIPT
-
7/31/2019 Validation Measurement Campaigns
1/6
ICS TelecomVALIDATION CAMPAIGNS
May 1997
-
7/31/2019 Validation Measurement Campaigns
2/6
VALIDATION N1
Transmitter : TDF - FUN RADIO - Croix de Guizay
Area : St. Etienne - France
Location : Long. : 42348 - Lat. : 452348Altitude : 867 meters
ERP : 2,000 Watts
Frequency : 96.3 MHz.
Service : FM Stereo
Transmitter Height : 80 meters
Path along which the Field Strength
was measured (in black).Field Strength Calculation according
to ICS TELECOM
(Model : Fresnel + Deygout 94)
Comparison Measurement/Simulation
The difference between the Simulation and the Measurement is lower than 6 dB for 94% of
the values along the path.
-
7/31/2019 Validation Measurement Campaigns
3/6
VALIDATION N1bis
(ITU-Rec. 370-7)
Transmitter : TDF - FUN RADIO - Croix de Guizay
Area : St. Etienne - FranceLocation : Long. : 42348 - Lat. : 452348
Altitude : 867 meters
ERP : 2,000 Watts
Frequency : 96.3 MHz.
Service : FM Stereo
Transmitter Height : 80 meters
Path along which the Field Strength
was measured (in black).
Field Strength Calculation according
to ICS TELECOM(Model : ITU-Rec. 370-7)
Comparison Measurement/Simulation
The difference between the Simulation and the Measurement is lower than 6 dB for 42% of
the values along the path.
-
7/31/2019 Validation Measurement Campaigns
4/6
VALIDATION N2
Transmitter : EUROTUNNEL
Area : Sangatte - FranceLocation : Channel Tunnel - French end.
Altitude : 11 meters
ERP : 3 Watts
Frequency : 444 MHz.
Service : Radiocommunication
Transmitter Height : 30 meters
Path along which the Field Strength was
measured.
Field Strength Calculation according
to ICS TELECOM(Model : Fresnel + Deygout 94
Diffraction)
Comparison Measurement/Simulation
The difference between the Simulation and the Measurement is lower than 6 dB for 89% of
the values along the path.
-
7/31/2019 Validation Measurement Campaigns
5/6
VALIDATION N2bis
(ITU-Rec. 370-7)
Transmitter : EUROTUNNEL
Area : Sangatte - France
Location : Channel Tunnel - French end.
Altitude : 11 meters
ERP : 3 Watts
Frequency : 444 MHz.
Service : Radiocommunication
Transmitter Height : 30 meters
Path along which the Field Strength was
measured. Field Strength Calculation according
to ICS TELECOM(Model : ITU-Rec. 370-7)
Comparison Measurement/Simulation
The difference between the Simulation and the Measurement is lower than 6 dB for 73% ofthe values along the path.
-
7/31/2019 Validation Measurement Campaigns
6/6
VALIDATION N3
Transmitter : INFOMOBILE - CORBREUSE
Area : Corbreuse - France
Location : Long. : 15733 - Lat. : 482938
Altitude : 149 meters
ERP : 475.47 Watts
Frequency : 169 MHz.
Service : Radiocommunication
Transmitter Height : 44 meters
Path along which the Field Strength was
measured (in black).
Field Strength Calculation
according to ICS TELECOM(Model : Fresnel + Deygout 94
Diffraction)
Comparison Measurement/Simulation
The difference between the Simulation and the Measurement is lower than 6 dB for 95% of
the values along the path.