vale - indicative price - sap bpc, srm & mobile - technical presentation - v-2.1
DESCRIPTION
m,mTRANSCRIPT
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
One Sap Vale BW-BPC, SRM and Mobile Infrastructure Solutions
August 03 , 2012
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.2
Disclaimers
CONFIDENTIALITY STATEMENT
This statement ensures Vale that HP shall maintain absolute secrecy of the facts (Procedures and Values) that shall be disclosed to HP. This information shall be used for HP procedures only. The activities comply with the Installment of Service Contract, which shall not be disclosed to others without prior consent from Vale.
PROPERTY STATEMENT
The information contained in this document, especially prepared for Vale, is confidential and belongs to HP. HP presents this document on the understanding that it shall be maintained in strict confidentiality by Vale, which shall only use it for evaluation of the services proposed.
Vale should not disclose the subject matter of this document or the items here described, including organizational concepts, and should neither duplicate it nor use it for other purposes without formal consent from HP. Upon confirmation of the proposed service as here described, through an HP contract, such contract shall establish the conditions for usage of such information.
PROPOSAL STATEMENT
This document was prepared in order to provide general information about the services that HP shall be able to offer. More specific terms and conditions shall be defined in the agreement for the services.
This document is not a legally binding offer of services. Therefore, its acceptance does not constitute any contractual obligation. HP has the commitment to negotiate in good faith an agreement that fairly represents a business contract of mutual acceptance. No legal obligation for HP shall exist until the agreement is duly signed by HP.
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
BW-BPC set-up
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.4
Sizing x Servers configuration
BW-BPC set-up
Sizing:
Servers configurations:
Important: Memory are adjusted 16GB/Core because hardware performance, and core for Apps are based (N, N +N), where +N is stand-by server, then 16 cores will be configuration (8, 8 +8) = 24 are needed;
SAP application
System Role
Target Server
Qty O.S.Recommended Config/server
Phase 1 - Scenario 1
BW-LSA + BPC
DB/CI Cluster
SD-21
vParHP-UX
14 cores, 128GB
SD-21
vParHP-UX
14 cores, 128GB
APP Servers
Bl890 i2 2HP-UX
16 cores, 256GB
Phase 2 - Scenario 2
BW-LSA + BPC
DB/CI Cluster
SD-21
vParHP-UX
16 cores, 128GB
SD-21
vParHP-UX
16 cores, 128GB
APP Servers
Bl890 i2 2HP-UX
28 cores, 256GB
Phase
ActionItem Type
Envir.
Instance
Function Platform Hostname O.S.Core Initia
l
Memory Initial
Core Sized
Memory Sized
Core Adde
d
Memory
AddedHardware required
RU by socket
1(+) add HW PRDLP0, LPJ
db SD2-1 CATOR2ENCLUS011/VLUNX045
HP-UX
8 128 14 224 6 961/2 - SD2 BL - 2 quad proc. x 128gb Small
1(+) add HW PRDLP0, LPJ
db SD2-3 CATOR2ENCLUS013/VLUNX046
HP-UX
8 128 14 224 6 961/2 - SD2 BL - 2 quad proc. x 128gb Small
1(+) add HW DRLP0, LPJ
db SD2-5 CAMKH1ENCLUS003/CAVACN36
HP-UX
8 128 14 224 6 961/2 - SD2 BL - 2 quad proc. x 128gb Small
1(+) add HW DRLP0, LPJ
appsBl890C i2 - stacked
NEWSERVER01HP-UX
6 48 16 256 10 208Using BL890C I2 ordered @ Mobile Phase 1 (MCC) Medium
1(+) add HW PRDLP0, LPJ
appsBl890C i2 - stacked
NEWSERVER02HP-UX
9 72 24 384 15 3121x Physical BL890C I2 to SCC Medium
2(+) expand
HW PRDLP0, LPJ
db SD2-1 CATOR2ENCLUS011/VLUNX045
HP-UX
14 224 16 256 2 32Using Blades SD-2 ordered @ Phase 1 Small
2(+) expand
HW PRDLP0, LPJ
db SD2-3 CATOR2ENCLUS013/VLUNX046
HP-UX
14 224 16 256 2 32Using Blades SD-2 ordered @ Phase 1 Small
2(+) expand
HW DRLP0, LPJ
db SD2-5 CAMKH1ENCLUS003/CAVACN36
HP-UX
14 224 16 256 2 32Using Blades SD-2 ordered @ Phase 1 Small
2(+) expand
HW DRLP0, LPJ
appsBl890C i2 - stacked
NEWSERVER01HP-UX
16 256 28 384 12 1281x Physical BL890C I2 Medium
2(+) expand
HW PRDLP0, LPJ
appsBl890C i2 - stacked
NEWSERVER02HP-UX
24 384 42 576 18 1921x Physical BL890C I2 Large
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.5
BW-BPC set-up Phase 1Hardware:• Installation of 03 Physical SD-2 blade on PRD/DR for LP0/LPJ DB/CI;
• Installation of 02 Physical BL890Ci2 blade on PRD/DR for LP0/LPJ Apps
Operating Systems:• Installation of 02 (two) O.S. Instances in PRD/DR LP0/LPJ Apps;
• Support for hardware installation of 02 Physical SD-2 blade on PRD/DR for LP0/LPJ DB/CI;
Sap DB/CI and Apps:• Support for hardware installation for 02 Physical SD-2 blade on
PRD/DR for LP0/LPJ DB/CI;
• Installation of 04 (four) APPS instances in new Physical BL890Ci2 blade on (02) PRD and (02) DR for LP0/LPJ Apps;
• Adjustments in 10 (ten) APPS instances in re-size of proc. and memory;
Phase 2Hardware• Expansion for LPO/LPJ DB/CI and Apps using the blades ordered
@phase 1;
Operating systems• Support for hardware expansion for LPO/LPJ DB/CI and Apps;
SAP DB/CI and Apps: • Support for hardware expansion for LPO/LPJ DB/CI and Apps ;
Installation and/or expansionPhas
eInstan
ce Type Action Envirnmt
Function Hardware O.S
.D.B
.SAP CI
SAP Apps
1 2 14
LP0, LPJ HW (+) add DR apps 1/2 - 2x Physical BL890C I2
db 1/2 - SD2 BL - 2 quad proc. x 128gb
PRD apps 1/2 - 2x Physical BL890C I2
db 1/2 - SD2 BL - 2 quad proc. x 128gb
OS image (+) add DR apps 1
PRD apps 1
(+) expand DR db
PRD db SAP APP (+) add DR apps 2 PRD apps 2
(+) expand DR apps 4
PRD apps 6
SAP DB/CI
(+) expand PRD db
2
LP0, LPJ HW (+)
expand DR apps Using BL890C I2 ordered @ Phase 1
db Using Blades SD-2 ordered @ Phase 1
PRD apps Using BL890C I2 ordered @ Phase 1
db Using Blades SD-2 ordered @ Phase 1
OS image
(+) expand DR apps
db PRD apps db
SAP APP (+) expand DR apps
PRD apps
SAP DB/CI
(+) expand PRD db
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.6
Other activities
BW-BPC set-up
All phases• Set up of storage and SAN networks;• Set up ofbackup agents, backup servers, tape libraries and VTL, set of tapes;• Configuration of ITSM tools, monitoring agents, threshold parameter;• BCRS, adjustments in Technical Disaster & Recovery Plan;
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.7
Servers overview @ MCC/SCC
BW-BPC set-up
DR:
DB/CI Apps
PDY/QAS:
DB/CI & Apps
DEV:
DB/CI & Apps PRD:
DB/CI Apps
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.8
Servers distribution
BW-BPC set-up
DB/CI currentBW-LSA Phase 1:
DB/CI with BW-LSA Phase 1 + BPC Phase 1 :
Part. Type
HostnameSD2-1Enc:
Cator2enclus011
HostnameSD2-3Enc:
Cator2enclus013
HostnameSD2-5Enc:
Camkh1enclus003
SAP ApplicationSCC
PRODSids
MCCPRE-PROD
Sids
Blade total
proc (quad core)
total cores sized
Phase1
cores ACTIVE
cores iCAPed ram
total cores sized
add cores
needed
Min. Proc. Needed (quad)
N vlunx001 vlunx002 vlunx043 ECC EP0 EC0 3 6 8 8 16 384 24 ~ ~N vlunx014 vlunx015 vlunx049 BI BP0 ~ 1 2 4 4 4 128 8 ~ ~N vlunx005 vlunx028 vlunx050 EP WP0 ~ 1 2 4 4 4 128 8 ~ ~V vlunx045 vlunx046 cavacn36 BW-LSA LP0/LPJ ~ 1 2 4 8 ~ 128 8 2 1 (4 core)V V
Part. Type
HostnameSD2-1Enc:
Cator2enclus011
HostnameSD2-3Enc:
Cator2enclus013
HostnameSD2-5Enc:
Camkh1enclus003
SAP ApplicationSCC
PRODSids
MCCPRE-PROD
Sids
Blade total
proc (quad core)
total cores sized
Phase1
cores ACTIVE
cores iCAPed ram
total cores sized
add cores
needed
Min. Proc. Needed (quad)
N vlunx001 vlunx002 vlunx043 ECC EP0 EC0 3 6 8 8 16 384 24 ~ ~N vlunx014 vlunx015 vlunx049 BI BP0 ~ 1 2 4 4 4 128 8 ~ ~N vlunx005 vlunx028 vlunx050 EP WP0 ~ 1 2 4 4 4 128 8 ~ ~V vlunx045 vlunx046 cavacn36 BW-LSA+BPC LP0/LPJ ~
24 14 ~ 224 14
V NEW NEW NEW MI HP0 ~ 1 4 64 V ~ ~ ~
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.9
Servers distribution
BW-BPC set-up
Applications:MCC Blade Servers for PPR/DR 'App' Servers SCC Blade Servers for PRODUCTION 'App' Servers
BLADEBlade Mode
l
Processor Arch
OS Processors COREs Threa
dsRAM GB
Max RAM for
iVMsTier ABAP
Dia InstJAVA Dia
InstDUAL
Dia Instmax sized cores
max sized RAM comment BLADE
Blade Mode
l
Processor Arch
OS Processors COREs Threa
dsRAM GB
Max RAM for
iVMsTier ABAP
Dia InstJAVA Dia
InstDUAL
Dia Instmax sized cores
max sized RAM comment
VLUNX02
6
Bl890C i2
ia64 HP-UX 8 32 64 512 450
PPR ER0 ~ ~ 16 128 installed
VLUNX003
Bl890C i2
ia64 HP-UX 8 32 64 512 450
PROD EP0 ~ ~ 16 128 installed
PPR ~ ~ ~ 0 0 no longer needed PROD ~ ~ BP0 0 0 no longer needed
PPR ~ ~ PR0 3 24 needed PROD ~ ~ PP0 3 24 neededPPR NR0 ~ ~ 3 24 needed PROD NP0 ~ ~ 3 24 neededPPR ~ ~ ~ 3 24 needed PROD ~ ~ WP0 3 24 neededPPR ~ ECR ~ 3 24 needed PROD ~ ECP ~ 3 24 neededPPR LP0 LPJ ~ 14 112 new PROD LP0 LPJ ~ 0 0 newPPR HP0 ~ ~ 8 64 new PROD HP0 ~ ~ 0 0 new
CPU utilization (average, peak) v. low v. low total > 50 400 CPU utilization (average, peak) v. low v. low total > 28 224 Memory Utilization (average, peak) v. low v. low Memory Utilization (average, peak) v. low v. low
VLUNX02
7
Bl890C i2
ia64 HP-UX 8 32 64 512 450
PPR ER0 ~ ~ 16 128 needed
VLUNX010
Bl890C i2
ia64 HP-UX 8 32 64 512 450
PROD EP0 ~ ~ 16 128 installed
PPR ~ ~ ~ 0 0 no longer needed PROD ~ ~ BP0 0 0 no longer needed
PPR ~ ~ PR0 3 24 needed PROD ~ ~ PP0 3 24 neededPPR NR0 ~ ~ 3 24 needed PROD NP0 ~ ~ 3 24 neededPPR ~ ~ ~ 3 24 needed PROD ~ ~ WP0 3 24 neededPPR ~ ECR ~ 3 24 needed PROD ~ ECP ~ 3 24 neededPPR LP0 LPJ ~ 14 112 new PROD LP0 LPJ ~ 14 112 newPPR HP0 ~ ~ 8 64 new PROD HP0 ~ ~ 8 64 new
CPU utilization (average, peak) v. low v. low total > 50 400 CPU utilization (average, peak) v. low v. low total > 50 400Memory Utilization (average, peak) v. low v. low Memory Utilization (average, peak) v. low v. low
NEWSERVER01
Bl890C i2
ia64 HP-UX 8 32 64 512 450
PPR ER0 ~ ~ new
CAVAVS08
Bl890C i2
ia64 HP-UX 8 32 64 512 450
PROD EP0 ~ ~ 16 128 needed
PPR ~ ~ ~ new PROD ~ ~ BP0 0 0 no longer needed
PPR ~ ~ PR0 new PROD ~ ~ PP0 3 24 neededPPR NR0 ~ ~ new PROD NP0 ~ ~ 3 24 neededPPR ~ ~ ~ new PROD ~ ~ WP0 3 24 neededPPR ~ ECR ~ new PROD ~ ECP ~ 3 24 neededPPR LP0 LPJ ~ new PROD LP0 LPJ ~ 14 112 newPPR HP0 ~ ~ new PROD HP0 ~ ~ 8 64 new
CPU utilization (average, peak) v. low v. low total > 0 0 CPU utilization (average, peak) v. low v. low total > 50 400Memory Utilization (average, peak) v. low v. low Memory Utilization (average, peak) v. low v. low
NEWSERVER02
Bl890C i2
ia64 HP-UX 8 32 64 512 450
PROD EP0 ~ ~ new
PROD ~ ~ BP0 new
PROD ~ ~ PP0 newPROD NP0 ~ ~ newPROD ~ ~ WP0 newPROD ~ ECP ~ newPROD LP0 LPJ ~ newPROD HP0 ~ ~ new
CPU utilization (average, peak) total > 0 0Memory Utilization (average, peak)
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
SRM set-up
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.11
Sizing x Servers configuration
SRM set-up
Sizing:
Servers configurations:
SAP app.
System Role
Target Server O.S. Recommended configuration per wave
Pilot Wave 1 Wave 2 Wave 3
SRM
DB/CI Cluster
SD-2 HP-UX1 vPar, 4 cores, 16GB
1 vPar, 8 cores, 80GB
1 vPar, 10 cores, 96GB1 vPar, 14 cores, 128GB
SD-2 HP-UX1 vPar, 4 cores, 16GB
1 vPar, 8 cores, 80GB
1 vPar, 10 cores, 96GB1 vPar, 14 cores, 128GB
APP ServersBl460 G7 or Gen8
Linux 2 bl460 G72 bl460 G7 (12c/96GB)
2 bl460 G7 (12c/96GB) + 1 bl460 Gen8 (12c/128GB)
2 bl460 G7 (12c/96GB) +2 bl460 Gen8 (12c/128GB)
Portal (wp0) BL890iC2 HP-UX 2 core, 16GB 2 core, 16GB 3 core, 24GB 3 core, 24GB
Phase Action Item
TypeEnvir
.Instanc
e Function Platform Hostname O.S. Core Initial
Memory Initial
Core Sized
Memory Sized
Core Adde
d
Memory
AddedHardware required RU by
socket
pilot (+) add HW DR WP0 web/apps
Bl890C i2 - stacked NEWSERVER03 HP-
UX 0 0 2 16 2 16 Using BL890C I2 ordered @ Mobile Phase 1 (MCC) Small
pilot (+) add HW PRD WP0 web/apps
Bl890C i2 - stacked NEWSERVER04 HP-
UX 0 0 3 24 3 24 Using BL890C I2 ordered @ BPC Phase 1 (SCC) Small
1 (+) expand HW PRD SP0,
SPJ db SD2-2 CATOR2ENCLUS012/CAVACN27
HP-UX 7 104 8 128 1 24 Using Blades SD-2 current Small
1 (+) expand HW PRD SP0,
SPJ db SD2-4 CATOR2ENCLUS014/CAVACN28
HP-UX 7 104 8 128 1 24 Using Blades SD-2 current Small
1 (+) expand HW DR SP0,
SPJ db SD2-6 CAMKH1ENCLUS004/CAVACN34
HP-UX 7 104 8 128 1 24 Using Blades SD-2 current Small
2 (+) add HW PRD SP0, SPJ db SD2-2 CATOR2ENCLUS012/
CAVACN27HP-UX 8 128 10 160 2 32 1 - SD2 BL - 2 quad proc. x 128gb Small
2 (+) add HW PRD SP0, SPJ db SD2-4 CATOR2ENCLUS014/
CAVACN28HP-UX 8 128 10 160 2 32 1 - SD2 BL - 2 quad proc. x 128gb Small
2 (+) add HW DR SP0, SPJ db SD2-6 CAMKH1ENCLUS004/
CAVACN34HP-UX 8 128 10 160 2 32 1 - SD2 BL - 2 quad proc. x 128gb Small
2 (+) add HW PRD SP0, SPJ apps Bl460C G8 -
stacked NEWSERVER05 Linux 0 0 12 128 12 128 1x bl460 Gen8 (12c/128GB) Large
2 (+) add HW DR SP0, SPJ apps Bl460C G8 -
stacked NEWSERVER06 Linux 0 0 12 128 12 128 1x bl460 Gen8 (12c/128GB) Large
3 (+) expand HW PRD SP0,
SPJ db SD2-2 CATOR2ENCLUS012/CAVACN27
HP-UX 10 160 14 224 4 64 Using Blades SD-2 ordered @ Phase 2 Small
3 (+) expand HW PRD SP0,
SPJ db SD2-4 CATOR2ENCLUS014/CAVACN28
HP-UX 10 160 14 224 4 64 Using Blades SD-2 ordered @ Phase 2 Small
3 (+) expand HW DR SP0,
SPJ db SD2-6 CAMKH1ENCLUS004/CAVACN34
HP-UX 10 160 14 224 4 64 Using Blades SD-2 ordered @ Phase 2 Small
3 (+) add HW PRD SP0, SPJ apps Bl460C G8 -
stacked NEWSERVER07 Linux 0 0 12 128 12 128 1x bl460 Gen8 (12c/128GB) Large
3 (+) add HW DR SP0, SPJ apps Bl460C G8 -
stacked NEWSERVER08 Linux 0 0 12 128 12 128 1x bl460 Gen8 (12c/128GB) Large
3 (+) expand HW DR WP0 web/
appsBl890C i2 - stacked NEWSERVER03 HP-
UX 2 16 3 16 1 8 Using BL890C I2 ordered @ Mobile Phase 1 (MCC) Small
3 (+) expand HW PRD WP0 web/
appsBl890C i2 - stacked NEWSERVER04 HP-
UX 3 24 4 24 1 8 Using BL890C I2 ordered @ BPC Phase 1 (SCC) Small
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.12
SRM set-up
PilotHardware:• Installation of 02 Physical BL890Ci2 blade on PRD/DR for WPO;
Operating Systems:• Installation of 02 (two) O.S. Instances in PRD/DR for WPO;
Sap DB/CI and Apps:• Installation of 14 DB/CI instances;
• Installation of 14 APPS instances;
Phase 1Hardware• Expansion of hardware for SP0/SPJ using the blades current;
SAP DB/CI and Apps: • Support for hardware expansion for SPO/SPJ DB/CI ;
Installation and/or expansion
.Phas
eInstan
ceType Action
Envirnmt
Function
HardwareO.S
.D.B.
SAP CI
SAP App
spilot 2 14 14 14
SD0, SDJ
2 2
SD1, SDG
SAP DB/CI
(+) add DEV apps/db 2 2
SP0, SPJ SAP APP (+) add DR apps 4 PRD apps 4
SAP DB/CI
(+) add PRD db 2 2
SQ0, SQJ
SAP DB/CI
(+) add QAS apps/db 2 2
SQ1, SQG
SAP DB/CI
(+) add QAS apps/db 2 2
SR0, SRJ
SAP DB/CI
(+) add PPR apps/db 2 2
SY1, SYG
SAP APP (+) add PDY apps 4
SAP DB/CI
(+) add PDY db 2 2
WP0 HW (+) add DRweb/apps
1/2 - Physical BL890C I2 (Same BPC)
PRDweb/apps
1/2 - Physical BL890C I2 (Same BPC)
OS image
(+) add DRweb/apps
1
PRDweb/apps
1
SAP APP (+) add DRweb/apps
1
PRDweb/apps
1
1
SP0, SPJ HW(+) expand
DR db Using Blades SD-2 current
PRD db Using Blades SD-2 current
SAP DB/CI
(+) expand
PRD db
2 2 4 SP0, SPJ HW (+) add DR apps 1x bl460 Gen8 (12c/128GB)
db1 - SD2 BL - 2 quad proc. x 128gb
PRD apps 1x bl460 Gen8 (12c/128GB)
db1 - SD2 BL - 2 quad proc. x 128gb
OS image
(+) add DR apps 1
PRD apps 1 SAP APP (+) add DR apps 2 PRD apps 2
SAP DB/CI
(+) expand
PRD db
3 2 4 SP0, SPJ HW (+) add DR apps 1x bl460 Gen8 (12c/128GB) PRD apps 1x bl460 Gen8 (12c/128GB)
(+) expand
DR dbUsing Blades SD-2 ordered @ Phase 2
PRD dbUsing Blades SD-2 ordered @ Phase 2
OS image
(+) add DR apps 1
PRD apps 1 SAP APP (+) add DR apps 2 PRD apps 2
SAP DB/CI
(+) expand
PRD db
WP0 HW(+) expand
DRweb/apps
1/2 - Physical BL890C I2 (Same BPC)
PRDweb/apps
1/2 - Physical BL890C I2 (Same BPC)
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.13
SRM set-up
Phase 2Hardware:• Installation of 03 Physical SD-2 blade in PRD/DR for SP0/SPJ DB/CI;
• Installation of 02 BL460 Gen8 in PRD/DR for SP0/SPJ Apps
Operating Systems:• Installation of 02 O.S. instances in PRD/DR for SPO/SPJ Apps;
Sap DB/CI and Apps:• Support for hardware expansion in PRD/DR for SPO/SPJ DB/CI;
• Installation of 04 APPS instances in PRD/DR for SPO/SPJ;
Phase 3Hardware:• Expansion of hardware SD-2 blade in PRD/DR for SP0/SPJ DB/CI;
• Installation of 02 BL460 Gen8 in PRD/DR for SP0/SPJ Apps
Operating Systems:• Installation of 02 O.S. instances in PRD/DR for SPO/SPJ Apps;
Sap DB/CI and Apps:• Support for hardware expansion in PRD/DR for SPO/SPJ DB/CI;
• Installation of 04 APPS instances in PRD/DR for SPO/SPJ;
Installation and/or expansion
.Phas
eInstan
ceType Action
Envirnmt
Function
HardwareO.S
.D.B.
SAP CI
SAP App
spilot 2 14 14 14
SD0, SDJ
2 2
SD1, SDG
SAP DB/CI
(+) add DEV apps/db 2 2
SP0, SPJ SAP APP (+) add DR apps 4 PRD apps 4
SAP DB/CI
(+) add PRD db 2 2
SQ0, SQJ
SAP DB/CI
(+) add QAS apps/db 2 2
SQ1, SQG
SAP DB/CI
(+) add QAS apps/db 2 2
SR0, SRJ
SAP DB/CI
(+) add PPR apps/db 2 2
SY1, SYG
SAP APP (+) add PDY apps 4
SAP DB/CI
(+) add PDY db 2 2
WP0 HW (+) add DRweb/apps
1/2 - Physical BL890C I2 (Same BPC)
PRDweb/apps
1/2 - Physical BL890C I2 (Same BPC)
OS image
(+) add DRweb/apps
1
PRDweb/apps
1
SAP APP (+) add DRweb/apps
1
PRDweb/apps
1
1
SP0, SPJ HW(+) expand
DR db Using Blades SD-2 current
PRD db Using Blades SD-2 current
SAP DB/CI
(+) expand
PRD db
2 2 4 SP0, SPJ HW (+) add DR apps 1x bl460 Gen8 (12c/128GB)
db1 - SD2 BL - 2 quad proc. x 128gb
PRD apps 1x bl460 Gen8 (12c/128GB)
db1 - SD2 BL - 2 quad proc. x 128gb
OS image
(+) add DR apps 1
PRD apps 1 SAP APP (+) add DR apps 2 PRD apps 2
SAP DB/CI
(+) expand
PRD db
3 2 4 SP0, SPJ HW (+) add DR apps 1x bl460 Gen8 (12c/128GB) PRD apps 1x bl460 Gen8 (12c/128GB)
(+) expand
DR dbUsing Blades SD-2 ordered @ Phase 2
PRD dbUsing Blades SD-2 ordered @ Phase 2
OS image
(+) add DR apps 1
PRD apps 1 SAP APP (+) add DR apps 2 PRD apps 2
SAP DB/CI
(+) expand
PRD db
WP0 HW(+) expand
DRweb/apps
1/2 - Physical BL890C I2 (Same BPC)
PRDweb/apps
1/2 - Physical BL890C I2 (Same BPC)
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.14
Other activities
SRM set-up
All phases• Set up of storage and SAN networks;• Set up ofbackup agents, backup servers, tape libraries and VTL, set of tapes;• Configuration of ITSM tools, monitoring agents, threshold parameter;• BCRS, adjustments in Technical Disaster & Recovery Plan;
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.15
Servers overview @ MCC/SCC
SRM set-up
PDY (DR):
DB/CI Apps
QAS:
DB/CI & Apps
DEV:
DB/CI & Apps PRD:
DB/CI Apps
PRD:
Portal
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.16
Servers distribution
SRM set-up
DB/CI Current:
DB/Ci with SRM :
Part. Type
HostnameSD2-2Enc:
Cator2enclus012
HostnameSD2-4Enc:
Cator2enclus014
HostnameSD2-6Enc:
Camkh1enclus004
SAP ApplicationSCC
PRODSids
MCCPRE-PROD
Sids
Blade total proc
total cores sized
Phase1
cores ACTIVE
cores iCAPed ram
total cores sized
addit. cores
needed
Min. Proc. Needed (quad)
N vlunx008 vlunx009 vlunx011 PI/GRC-NFE PP0/NP0 PR0/NR0 1 2 4 4 4 128 8 ~ ~V vlunx047 vlunx030 vlunx052 EC ECP ECR
4
2 4 8 ~ 128 8 ~ ~V cavacn25 cavacn26 cavacn33 CRM/MI CP0/CPJ/HP0 CR0/CRJ 1 1 4 ~ 64 4 ~ ~V cavacn27 cavacn27 cavacn34 EP WPE WRE 2 3 8 ~ 128 14 6 2 (8core)V cavacn29 cavacn30 cavacn35 MDM/Search-UI MPC/SCP MRC/SCR 2 5 8 ~ 128 13 5 1 (4core)V cavacn31 cavacn32 ~ GRC-AC GP0 ~ 1 3 4 ~ 64 6 2 1 (4core)V ~ ~ ~ N vlunx019 vlunx020 vlunx053 MDM MP0 1 2 4 4 4 128 8 ~ ~
Part. Type
HostnameSD2-2Enc:
Cator2enclus012
HostnameSD2-4Enc:
Cator2enclus014
HostnameSD2-6Enc:
Camkh1enclus004
SAP ApplicationSCC
PRODSids
MCCPRE-PROD
Sids
Blade total proc
total cores sized
Phase1
cores ACTIVE
cores iCAPed ram
total cores sized
addit. cores
needed
Min. Proc. Needed (quad)
N vlunx008 vlunx009 vlunx011 PI/GRC-NFE PP0/NP0 PR0/NR0 1 2 4 4 4 128 8 ~ ~V vlunx047 Vlunx030 vlunx052 EC ECP ECR
4
2 4 8 ~ 128 8 ~ ~V cavacn25 Cavacn26 cavacn33 CRM CP0/CPJ CR0/CRJ 1 1 4 ~ 64 4 ~ ~V cavacn27 Cavacn27 cavacn34 EP/and SRM WPE/SP0/SPJ WRE/SR0/SRJ 1 8 8 ~ 128 16 8 2(8cores)V cavacn29 Cavacn30 cavacn35 MDM/Search-UI MPC/SCP MRC/SCR 2 5 8 ~ 128 13 5 1 (4core)V cavacn31 Cavacn32 ~ GRC-AC GP0 ~ 1 3 4 ~ 64 6 2 1 (4core)V ~ ~ ~ N vlunx019 Vlunx020 vlunx053 MDM MP0 1 2 4 4 4 128 8 ~ ~
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.17
Servers distribution
SRM set-up
Applications Intel Blades for SAP Dia Inst [CRM/EP/SRM] @ MCC Intel Blades for SAP Dia Inst [CRM/EP/SRM] @ SCC
BLADE Blade Model
Processor
ArchOS Proces
sors COREs Threads
RAM GB
Max RAM
for SAPTier ABAP DIA
InstJAVA Dia
InstMax
Cores Sized
Max RAM Sized Comments BLADE
Blade Model
Processor
ArchOS Proces
sors COREs Threads
RAM GB
Max RAM for
iVMsTier ABAP DIA
InstJAVA Dia
InstMax
Cores Sized
Max RAM Sized Comments
cavaas39
BL460C G7
x86_64
RHEL
Server 5.7
2 12 24 96 85
PPR CR0 CRJ installed
cavaas37
BL460C G7
x86_64
RHEL
Server 5.7
2 12 24 96 85
PPR CR0 CRJ installedPPR ~ WRE installed PPR ~ WRE installedPPR SR0 SRJ # # new PPR SR0 SRJ # # new
CPU utilization (average, peak) ? ? CPU utilization (average, peak) ? ? Memory Utilization (average, peak) ? ? Memory Utilization (average, peak) ? ?
cavaas40
BL460C G7
x86_64
RHEL
Server 5.7
2 12 24 96 85
PPR CR0 CRJ installed
cavaas38
BL460C G7
x86_64
RHEL
Server 5.7
2 12 24 96 85
PPR CR0 CRJ installedPPR ~ WRE installed PPR ~ WRE installedPPR SR0 SRJ # # new PPR SR0 SRJ # # new
CPU utilization (average, peak) ? ? CPU utilization (average, peak) ? ? Memory Utilization (average, peak) ? ? Memory Utilization (average, peak) ? ?
new wave
1
BL460C G8
x86_64
RHEL
Server 5.7
2 12 24 128 85
PPR CR0 CRJ installed
new wave 1
BL460C G8
x86_64
RHEL
Server 5.7
2 12 24 128 85
PPR CR0 CRJ installedPPR ~ WRE installed PPR ~ WRE installedPPR SR0 SRJ # # new PPR SR0 SRJ # # new
CPU utilization (average, peak) na na CPU utilization (average, peak) na na Memory Utilization (average, peak) na na Memory Utilization (average, peak) na na
new wave 2-3
BL460C G8
x86_64
RHEL
Server 5.7
2 12 24 128 85
PPR CR0 CRJ installed
new wave 2-3
BL460C G8
x86_64
RHEL
Server 5.7
2 12 24 128 85
PPR CR0 CRJ installedPPR ~ WRE installed PPR ~ WRE installedPPR SR0 SRJ # # new PPR SR0 SRJ # # new
CPU utilization (average, peak) na na CPU utilization (average, peak) na na Memory Utilization (average, peak) na na Memory Utilization (average, peak) na na
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Mobile set-up
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.19
Sizing x Servers configuration
Mobile set-up
Sizing:
Servers configurations:
System Role
Target Server Recommended Config per Phase
Phase 1 Phase 2 Phase 3 Phase 4 Phase 5
DB/CI Cluster
SD-21 vPar, 4 cores,
48GB1 vPar, 4 cores,
48GB1 vPar, 4 cores,
48GB1 vPar, 4 cores,
48GB1 vPar, 4 cores,
48GB
SD-21 vPar, 4 cores,
48GB1 vPar, 4 cores,
48GB1 vPar, 4 cores,
48GB1 vPar, 4 cores,
48GB1 vPar, 4 cores,
48GB
APP Servers2 x BL890 i2
(shared APP svr)03 cores, 32GB 04 cores, 48GB 06 cores, 64GB 08 cores, 80GB 08 cores, 80GBPhas
e Action Item Type
Envir.
Instance Function Platform Hostname O.S.
Core Initia
l
Memory
Initial
Core Sized
Memory Sized
Core Added
Memory Added Hardware required RU by
socket
1 (+) add HW PRD HP0 nw/db SD2-1 CATOR2ENCLUS011 HP-UX 4 64 4 64 1/2 - SD2 BL - 2 quad proc. x 128gb
(Same BPC) Small
1 (+) add HW PRD HP0 nw/db SD2-3 CATOR2ENCLUS013 HP-UX 4 64 4 64 1/2 - SD2 BL - 2 quad proc. x 128gb
(Same BPC) Small
1 (+) add HW DR HP0 nw/db SD2-5 CAMKH1ENCLUS003 HP-UX 4 64 4 64 1/2 - SD2 BL - 2 quad proc. x 128gb
(Same BPC) Small
1 (+) add HW PRD HP0 nw/apps Bl890C i2 - stacked NEWSERVER09 HP-UX 6 48 6 48 Using BL890C I2 ordered @ BPC Phase
1 (SCC) Small
1 (+) add HW DR HP0 nw/apps Bl890C i2 - stacked NEWSERVER10 HP-UX 4 32 4 32 1x Physical BL890C I2 to MCC Small
1 (+) expand HW PRD AP0,
UPO sup/afaria/db Vmware CAVAAS50 Windows 2 16 4 32 2 16 VMWare Farm > BL620C HW (05 = 3
prd, 03 dr) virtual
1 (+) add HW PRD UP0 sup/apps Vmware NEWSERVER11 Windows 4 32 4 32 VMWare Farm > BL620C HW (05 = 3
prd, 03 dr) virtual
1 (+) add HW PRD UP0 sup/apps Vmware NEWSERVER12 Windows 4 32 4 32 VMWare Farm > BL620C HW (05 = 3
prd, 03 dr) virtual
1 (+) expand HW DR AP0,
UPO sup/afaria/db Vmware CAVAAS45 Windows 2 16 4 32 2 16 VMWare Farm > BL620C HW (05 = 3
prd, 03 dr) virtual
1 (+) add HW DR UP0 sup/apps Vmware NEWSERVER13 Windows 4 32 4 32 VMWare Farm > BL620C HW (05 = 3
prd, 03 dr) virtual
1 (+) add HW DR UP0 sup/apps Vmware NEWSERVER14 Windows 4 32 4 32 VMWare Farm > BL620C HW (05 = 3
prd, 03 dr) virtual
1 (+) expand HW QAS UQ0,
AQ0sup/afa/apps/db Vmware CAVAAS46 Windo
ws 2 16 4 32 2 16 VMWare Farm > BL620C HW (05 = 3 prd, 03 dr) virtual
1 (+) expand HW DEV UD0,
AD0sup/afa/apps/db Vmware CAVAAS44 Windo
ws 2 16 4 32 2 16 VMWare Farm > BL620C HW (05 = 3 prd, 03 dr) virtual
1 (+) add HW PRD AP0 afaria/apps Vmware NEWSERVER15 Windows 2 8 2 8 VMWare Farm > BL620C HW (05 = 3
prd, 03 dr) virtual
1 (+) add HW PRD AP0 afaria/apps Vmware NEWSERVER16 Windows 2 8 2 8 VMWare Farm > BL620C HW (05 = 3
prd, 03 dr) virtual
1 (+) add HW DR AP0 afaria/apps Vmware NEWSERVER17 Windows 2 8 2 8 VMWare Farm > BL620C HW (05 = 3
prd, 03 dr) virtual
1 (+) add HW DR AP0 afaria/apps Vmware NEWSERVER18 Windows 2 8 2 8 VMWare Farm > BL620C HW (05 = 3
prd, 03 dr) virtual
1 (+) add HW PRD RP0 relay Vmware NEWSERVER21 Windows 2 8 2 8 VMWare Farm > BL620C HW (05 = 3
prd, 03 dr) virtual
1 (+) add HW PRD ctl sybase ctrl center Vmware NEWSERVER22 Windo
ws 2 8 2 8 VMWare Farm > BL620C HW (05 = 3 prd, 03 dr) virtual
1 (+) add HW DR ctl sybase ctrl center Vmware NEWSERVER23 Windo
ws 2 8 2 8 VMWare Farm > BL620C HW (05 = 3 prd, 03 dr) virtual
1 (+) add HW PRD ctl VMWARE Site RM. Vmware NEWSERVER24 Windo
ws 2 8 2 8 VMWare Farm > BL620C HW (05 = 3 prd, 03 dr) virtual
1 (+) add HW DR ctl VMWARE Site RM. Vmware NEWSERVER25 Windo
ws 2 8 2 8 VMWare Farm > BL620C HW (05 = 3 prd, 03 dr) virtual
2 (+) expand HW PRD HP0 nw/apps Bl890C i2 -
stacked NEWSERVER09 HP-UX 6 48 9 72 3 24 28% BL890C I2 to SCC Small
2 (+) expand HW DR HP0 nw/apps Bl890C i2 -
stacked NEWSERVER10 HP-UX 4 32 6 48 2 16 28% BL890C I2 to MCC Small
3 (+) expand HW PRD HP0 nw/apps Bl890C i2 -
stacked NEWSERVER09 HP-UX 9 72 18 144 9 72 42% BL890C I2 to SCC Medium
3 (+) expand HW DR HP0 nw/apps Bl890C i2 -
stacked NEWSERVER10 HP-UX 6 48 12 96 6 48 42% BL890C I2 to MCC Small
4 (+) expand HW PRD HP0 nw/apps Bl890C i2 -
stacked NEWSERVER09 HP-UX 18 144 24 192 6 48 30% BL890C I2 to SCC Small
4 (+) expand HW DR HP0 nw/apps Bl890C i2 -
stacked NEWSERVER10 HP-UX 12 96 16 128 4 32 30% BL890C I2 to MCC Small
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.20
Mobile set-up
Phase 1Hardware:• Installation of 01 Physical BL890C I2 and 1/2 - SD2 BL - 2 quad proc. x
128gb (Same BPC) in PRD/DR for HPO Netweaver Mobile;
• Installation of VMWare Farm > BL620C HW (05 = 3 prd, 03 dr) to support PRD/DR for SUP, Afaria, Relay and utility servers;
Operating Systems:• Installation of 15 O.S. Instances in PRD/DR;
Sap DB/CI and Apps:• Migration of 01 DB instances, 01 NetWeaver PRD to new vPar;
• Installation of 06 DB instances, 02 NetWeaver DR/TRN, 02 sup, 02 Afaria in PRD/DR;
• Installation of 07 CI “like” instances ctrl, vmware, relay, and NetWeaver;
• Installation of 15 APPS instances;
Installation and/or expansion
.Phas
eInstan
ceType Action
Envirnmt
Function HardwareO.S
.D.B.
SAP CI
SAP App
s1 15 6 7 15
HP0 HW (+) add DR nw/apps 1x Physical BL890C I2
nw/db1/2 - SD2 BL - 2 quad proc. x 128gb (Same BPC)
PRD nw/apps 1x Physical BL890C I2
nw/db1/2 - SD2 BL - 2 quad proc. x 128gb (Same BPC)
OS image
(+) add DR nw/apps 1
nw/db PRD nw/apps 1 nw/db SAP APP (+) add DR nw/apps 3 PRD nw/apps 4
SAP DB/CI
(+) add PRD nw/db 1 1
HT0SAP DB/CI
(+) add TRN nw/apps/db 1 1
ctl HW (+) add DRsybase ctrl center
VMWare Farm > BL620C HW (05 = 3 prd, 03 dr)
VMWARE Site RM.
VMWare Farm > BL620C HW (05 = 3 prd, 03 dr)
PRDsybase ctrl center
VMWare Farm > BL620C HW (05 = 3 prd, 03 dr)
VMWARE Site RM.
VMWare Farm > BL620C HW (05 = 3 prd, 03 dr)
OS image
(+) add DRsybase ctrl center
1
VMWARE Site RM.
1
PRDsybase ctrl center
1
VMWARE Site RM.
1
SAP DB/CI
(+) add DRsybase ctrl center
1
VMWARE Site RM.
1
PRDsybase ctrl center
1
VMWARE Site RM.
1
UP0 HW (+) add DR sup/appsVMWare Farm > BL620C HW (05 = 3 prd, 03 dr)
PRD sup/appsVMWare Farm > BL620C HW (05 = 3 prd, 03 dr)
OS image
(+) add DR sup/apps 2
PRD sup/apps 2 SAP APP (+) add DR sup/apps 2 PRD sup/apps 2
UQ0, AQ0
HW(+) expand
QASsup/afa/apps/db
VMWare Farm > BL620C HW (05 = 3 prd, 03 dr)
UD0, AD0
HW(+) expand
DEVsup/afa/apps/db
VMWare Farm > BL620C HW (05 = 3 prd, 03 dr)
AP0 HW (+) add DR afaria/appsVMWare Farm > BL620C HW (05 = 3 prd, 03 dr)
PRD afaria/appsVMWare Farm > BL620C HW (05 = 3 prd, 03 dr)
OS image
(+) add DR afaria/apps 2
PRD afaria/apps 2 SAP APP (+) add DR afaria/apps 2 PRD afaria/apps 2
RP0 HW (+) add PRD relayVMWare Farm > BL620C HW (05 = 3 prd, 03 dr)
OS image
(+) add PRD relay 1
SAP CI (+) add PRD relay 1
AP0, UPO
HW(+) expand
DR sup/afaria/dbVMWare Farm > BL620C HW (05 = 3 prd, 03 dr)
PRD sup/afaria/dbVMWare Farm > BL620C HW (05 = 3 prd, 03 dr)
SAP DB (+) add DR sup/afaria/db 2 PRD sup/afaria/db 2
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.21
Mobile set-up
Phase 2, 3 and 4Hardware:• Expansion of hardware using BL890C I2 in PRD/DR for HP0;
Operating Systems:• Support expansion of hardware in PRD/DR for HPO O.S. instances;
Sap DB/CI and Apps:• Support for hardware expansion in PRD/DR for HPO Apps instances;
Phase 5Hardware:• There isn´t no change, the sizing is the same of Phase 4;
Operating Systems:• There isn´t no change, the sizing is the same of Phase 4;
Sap DB/CI and Apps:• There isn´t no change, the sizing is the same of Phase 4;
Installation and/or expansion
.Phase
Instance Type Action Envirn
mtFuncti
on Hardware O.S.
D.B.
SAP CI
SAP App
s
2
HP0 HW (+) expand DR nw/
appsExpand or add BL890C I2 to SCC
PRD nw/apps
Expand or add BL890C I2 to MCC
OS image
(+) expand DR nw/
apps
PRD nw/apps
SAP APP
(+) expand DR nw/
apps
PRD nw/apps
3
HP0 HW (+) expand DR nw/
appsExpand or add BL890C I2 to SCC
PRD nw/apps
Expande or add BL890C I2 to MCC
OS image
(+) expand DR nw/
apps
PRD nw/apps
SAP APP
(+) expand DR nw/
apps
PRD nw/apps
4
HP0 HW (+) expand DR nw/
appsUsing BL890C I2 ordered @ Phase before
PRD nw/apps
Using BL890C I2 ordered @ Phase before
OS image
(+) expand DR nw/
apps
PRD nw/apps
SAP APP
(+) expand DR nw/
apps
PRD nw/apps
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.22
Other activities
Mobile set-up
All phases• Set up of storage and SAN networks;• Set up ofbackup agents, backup servers, tape libraries and VTL, set of tapes;• Configuration of ITSM tools, monitoring agents, threshold parameter;• BCRS, adjustments in Technical Disaster & Recovery Plan;
Important: • Vale need to provide network infra-structure for the deploy of Mobile Environment;• 2 x 2 connections 10GB networks ports for connect mobile SD2 vPar;
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.23
Servers overview @ MCC/SCC
Mobile set-up
QAS:
DB/CI & Apps
DEV:
DB/CI & Apps PRD:
DB/CI Apps
DR:
DB/CI Apps
SD2-1CATOR2ENCLUS011
vPARnewserver?
?HP-UX
SD2-3CATOR2ENCLUS
013
vPARnewserver?
?HP-UX
SD2-5CATOR2ENCLUS
003
vPARnewserver?
?HP-UX
HP0
HP0
HP0
HP0
HP0
HP0
HP0
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.24
Servers distribution
Mobile set-up
DB/CI Current:
DB/Ci with SRM :
Part. Type
HostnameSD2-2Enc:
Cator2enclus012
HostnameSD2-4Enc:
Cator2enclus014
HostnameSD2-6Enc:
Camkh1enclus004
SAP ApplicationSCC
PRODSids
MCCPRE-PROD
Sids
Blade total proc
total cores sized
Phase1
cores ACTIVE
cores iCAPed ram
total cores sized
addit. cores
needed
Min. Proc. Needed (quad)
N vlunx008 vlunx009 vlunx011 PI/GRC-NFE PP0/NP0 PR0/NR0 1 2 4 4 4 128 8 ~ ~V vlunx047 vlunx030 vlunx052 EC ECP ECR
4
2 4 8 ~ 128 8 ~ ~V cavacn25 cavacn26 cavacn33 CRM/MI CP0/CPJ/HP0 CR0/CRJ 1 1 4 ~ 64 4 ~ ~V cavacn27 cavacn27 cavacn34 EP WPE WRE 2 3 8 ~ 128 14 6 2 (8core)V cavacn29 cavacn30 cavacn35 MDM/Search-UI MPC/SCP MRC/SCR 2 5 8 ~ 128 13 5 1 (4core)V cavacn31 cavacn32 ~ GRC-AC GP0 ~ 1 3 4 ~ 64 6 2 1 (4core)V ~ ~ ~ N vlunx019 vlunx020 vlunx053 MDM MP0 1 2 4 4 4 128 8 ~ ~
Part. Type
HostnameSD2-1Enc:
Cator2enclus011
HostnameSD2-3Enc:
Cator2enclus013
HostnameSD2-5Enc:
Camkh1enclus003
SAP ApplicationSCC
PRODSids
MCCPRE-PROD
Sids
Blade total
proc (quad core)
total cores sized
Phase1
cores ACTIVE
cores iCAPed ram
total cores sized
add cores
needed
Min. Proc. Needed (quad)
N vlunx001 vlunx002 vlunx043 ECC EP0 EC0 3 6 8 8 16 384 24 ~ ~N vlunx014 vlunx015 vlunx049 BI BP0 ~ 1 2 4 4 4 128 8 ~ ~N vlunx005 vlunx028 vlunx050 EP WP0 ~ 1 2 4 4 4 128 8 ~ ~V vlunx045 vlunx046 cavacn36 BW-LSA+BPC LP0/LPJ ~
24 14 ~ 224 14
V NEW NEW NEW MI HP0 ~ 1 4 64 V ~ ~ ~
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.25
Servers distribution
Mobile set-up
ApplicationsMCC Blade Servers for PPR/DR 'App' Servers SCC Blade Servers for PRODUCTION 'App' Servers
BLADEBlade Mode
l
Processor Arch
OS Processors COREs Threa
dsRAM GB
Max RAM for
iVMsTier ABAP
Dia InstJAVA Dia
InstDUAL
Dia Instmax sized cores
max sized RAM comment BLADE
Blade Mode
l
Processor Arch
OS Processors COREs Threa
dsRAM GB
Max RAM for
iVMsTier ABAP
Dia InstJAVA Dia
InstDUAL
Dia Instmax sized cores
max sized RAM comment
VLUNX02
6
Bl890C i2
ia64 HP-UX 8 32 64 512 450
PPR ER0 ~ ~ 16 128 installed
VLUNX003
Bl890C i2
ia64 HP-UX 8 32 64 512 450
PROD EP0 ~ ~ 16 128 installed
PPR ~ ~ ~ 0 0 no longer needed PROD ~ ~ BP0 0 0 no longer needed
PPR ~ ~ PR0 3 24 needed PROD ~ ~ PP0 3 24 neededPPR NR0 ~ ~ 3 24 needed PROD NP0 ~ ~ 3 24 neededPPR ~ ~ ~ 3 24 needed PROD ~ ~ WP0 3 24 neededPPR ~ ECR ~ 3 24 needed PROD ~ ECP ~ 3 24 neededPPR LP0 LPJ ~ 14 112 new PROD LP0 LPJ ~ 0 0 newPPR HP0 ~ ~ 8 64 new PROD HP0 ~ ~ 0 0 new
CPU utilization (average, peak) v. low v. low total > 50 400 CPU utilization (average, peak) v. low v. low total > 28 224 Memory Utilization (average, peak) v. low v. low Memory Utilization (average, peak) v. low v. low
VLUNX02
7
Bl890C i2
ia64 HP-UX 8 32 64 512 450
PPR ER0 ~ ~ 16 128 needed
VLUNX010
Bl890C i2
ia64 HP-UX 8 32 64 512 450
PROD EP0 ~ ~ 16 128 installed
PPR ~ ~ ~ 0 0 no longer needed PROD ~ ~ BP0 0 0 no longer needed
PPR ~ ~ PR0 3 24 needed PROD ~ ~ PP0 3 24 neededPPR NR0 ~ ~ 3 24 needed PROD NP0 ~ ~ 3 24 neededPPR ~ ~ ~ 3 24 needed PROD ~ ~ WP0 3 24 neededPPR ~ ECR ~ 3 24 needed PROD ~ ECP ~ 3 24 neededPPR LP0 LPJ ~ 14 112 new PROD LP0 LPJ ~ 14 112 newPPR HP0 ~ ~ 8 64 new PROD HP0 ~ ~ 8 64 new
CPU utilization (average, peak) v. low v. low total > 50 400 CPU utilization (average, peak) v. low v. low total > 50 400Memory Utilization (average, peak) v. low v. low Memory Utilization (average, peak) v. low v. low
NEWSERVER01
Bl890C i2
ia64 HP-UX 8 32 64 512 450
PPR ER0 ~ ~ new
CAVAVS08
Bl890C i2
ia64 HP-UX 8 32 64 512 450
PROD EP0 ~ ~ 16 128 needed
PPR ~ ~ ~ new PROD ~ ~ BP0 0 0 no longer needed
PPR ~ ~ PR0 new PROD ~ ~ PP0 3 24 neededPPR NR0 ~ ~ new PROD NP0 ~ ~ 3 24 neededPPR ~ ~ ~ new PROD ~ ~ WP0 3 24 neededPPR ~ ECR ~ new PROD ~ ECP ~ 3 24 neededPPR LP0 LPJ ~ new PROD LP0 LPJ ~ 14 112 newPPR HP0 ~ ~ new PROD HP0 ~ ~ 8 64 new
CPU utilization (average, peak) v. low v. low total > 0 0 CPU utilization (average, peak) v. low v. low total > 50 400Memory Utilization (average, peak) v. low v. low Memory Utilization (average, peak) v. low v. low
NEWSERVER02
Bl890C i2
ia64 HP-UX 8 32 64 512 450
PROD EP0 ~ ~ new
PROD ~ ~ BP0 new
PROD ~ ~ PP0 newPROD NP0 ~ ~ newPROD ~ ~ WP0 newPROD ~ ECP ~ newPROD LP0 LPJ ~ newPROD HP0 ~ ~ new
CPU utilization (average, peak) total > 0 0Memory Utilization (average, peak)
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.26
Servers distribution
Mobile set-up
VMWareVIRTUAL MACHINES - Non-Prod - MCC VMWARE Farm VIRTUAL MACHINES - PRODUCTION - SCC VMWARE Farm
Environment Virtual Machine Role SAP Sids Tier OS vCPU RAM Temp or Perm Comments Environment Virtual Machine Role SAP Sids Tier OS vCPU RAM Temp or Perm Comments
TIBCO CAMKH1TIBCAS001 Agent ~~~~ NSSR W2K8 2 8 temp or perm installed TREX cator2valeas076 SAP Trex - Slave 1 TP0 PROD RHEL 2 8 Perm installed
TIBCO CAMKH1TIBCAS002 Ems #1 ~~~~ NSSR W2K8 4 16 temp or perm installed TREX cator2valeas077 SAP Trex - Slave 2 TP0 PROD RHEL 2 8 Perm installed
Documentum CAMKH1TIBCAS003 Test Server #1 ~~~~ NSSR RHEL 4 16 temp or perm installed TREX cator2valeas084 SAP Trex Master TP0 PROD RHEL 2 8 Perm installed
TIBCO CAMKH1TIBCAS004 BW/BC #1 ~~~~ NSSR W2K8 4 16 temp or perm installed TREX cator2valeas085 SAP Trex Master Backup TP0 PROD RHEL 2 8 Perm installed
TIBCO CAMKH1TIBCAS005 BW/BC #2 ~~~~ NSSR W2K8 4 16 temp or perm installed VMWARE cator2valeus484 VMWare Virtual Center ~~~~ PROD W2K8 8 24 Perm installed
TIBCO CAMKH1TIBCAS006 BC (DMZ) ~~~~ NSSR W2K8 1 1 temp or perm installed EP Web Disp cavaas31 Web Dispatcher (DMZ) DP0 PROD RHEL 2 8 Perm installed
TIBCO CAMKH1TIBCAS007 Mgmt ~~~~ NSSR W2K8 2 8 temp or perm installed EP Web Disp cavaas32 Web Dispatcher (DMZ) DP0 PROD RHEL 2 8 Perm installed
TIBCO CAMKH1TIBCAS008 Agent ~~~~ NSSR W2K8 2 8 temp or perm installed SYBASE cavaas49 Sysbase Relay Server (DMZ) ~~~~ PROD W2K8 2 8 Perm installed
TIBCO CAMKH1TIBCAS009 EMS #1 ~~~~ NSSR W2K8 4 16 temp or perm installed SYBASE cavaas50 Unwired Platform / Afaria ~~~~ PROD W2K8 2 16 Perm installed
Documentum CAMKH1TIBCAS010 Test Server #2 ~~~~ NSSR RHEL 4 16 temp or perm installed SYBASE new SUP Data tier PROD W2K8 4 32 Perm new
TIBCO CAMKH1TIBCAS011 BW/BC #1 ~~~~ NSSR W2K8 4 16 temp or perm installed SYBASE new SUP Server #1 PROD W2K8 4 32 Perm new
TIBCO CAMKH1TIBCAS012 BW/BC #2 ~~~~ NSSR W2K8 4 16 temp or perm installed SYBASE new SUP Server #2 PROD W2K8 4 32 Perm new
TIBCO CAMKH1TIBCAS013 BC (DMZ) ~~~~ NSSR W2K8 1 1 temp or perm installed SYBASE new Sybase Relay Server (DMZ) #1 PROD W2K8 2 8 Perm new
TIBCO CAMKH1TIBCAS014 Mgmt ~~~~ NSSR W2K8 2 8 temp or perm installed SYBASE new Sybase Relay Server (DMZ) #2 PROD W2K8 2 8 Perm new
TREX CAMKH1VALEAS018 SAP Trex TP0 dr DR RHEL 2 8 perm installed SYBASE new Afaria Server#1 PROD W2K8 2 8 Perm newTREX CAMKH1VALEAS019 SAP Trex TQ0 QAS RHEL 2 8 perm installed SYBASE new Afaria Server#2 PROD W2K8 2 8 Perm newTREX CAMKH1VALEAS020 SAP Trex TD0 DEV RHEL 2 8 perm installed SYBASE new Sybase Control Center PROD W2K8 2 8 Perm new
VMWARE camkh1valeus042 VMWare Virtual Center ~~~~ NonP, DR W2K8 1 8 perm installed VMWARE new VMWARE Site Recovery Mgr PROD W2K8 2 8 Perm newEP Web Disp cavaas41 Web Dispatcher (DMZ) DQ0, DP0 DR NonP, DR RHEL 2 8 perm installed Mercury BPM new SAP Business Process Monitor ~~~~ PROD XP ? 2 4 Perm
SYBASE cavaas43 Sysbase Relay Server (DMZ) ~~~~ DEV W2K8 2 8 perm installed SYBASE cavaas44 Unwired Platform / Afaria ~~~~ DEV W2K8 2 16 perm installed SYBASE cavaas45 Unwired Platform / Afaria ~~~~ DR W2K8 2 16 perm installed SYBASE cavaas46 Unwired Platform / Afaria ~~~~ QAS W2K8 2 16 perm installed SYBASE cavaas47 Sysbase Relay Server (DMZ) ~~~~ DR W2K8 2 8 perm installed SYBASE cavaas48 Sysbase Relay Server (DMZ) ~~~~ QAS W2K8 2 8 perm installed
BO Explorer CAVAAS51 BO Explorer POC ~~~~ NSSR W2K8 4 16 temp installed VMWARE new VMs for DR with SRM (?) PROD W2K8 2 8 Perm new
total vCPU and RAM Assigned 69 136 total vCPU and RAM Assigned 50 244
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.27
Overview of all components in PRD: NetWeaver Mobile, Sybase Relay, SUP and Afaria
Mobile set-up
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Clustering
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.29
HP ServiceGuard
Set-up a high-availability clustering solution
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Downtime/outages
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.31
BW-BPC Downtime (and MI)
• In BPC phase 1 we will need to add new HW (SD2 blade).
• This requires a reboot to add the HW to the nPAR.
• Estimated downtime for the reboot is 02 hours
• It will impact BW-LSA, no impact to ECC (EP0), BI (BP0) or EP (WP0).
• In BPC phase 2 we will need to re-assign the SD2 blade HW released from BI (BP0) Decomisioning.
• This requires a reboot to add this HW to the BW-LSA and MI nPAR.
• Estimated downtime for the reboot is 02 hours
• it will impact BW-LSA and MI, no impact to ECC (EP0) or EP (WP0).
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.32
SRM Downtime
• During installation and cluster configuration / testing we will have 10-20 hours (estimated) of downtime;
• • It will impact all applications
running on hosts cavacn27 and cavacn28: EP and TREX (nfs share) environment.
• And in the future wave 2 will be need to add new HW (SD2 blade) and then will have another downtime (at least 2 hours) for the nPar
• it will impact all the vPARs running in it: SRM-MDM Catalog, SearchUI, GRC-AC ,CRM and EC environment, EP TREX and SRM.
• In future Phase 2 for SRM project, when the other SD2 blade hw is added, this would also require downtime (for a reboot, at least 2 hours) unless both blades were added at the same time.
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.33
Mobile Downtime
• In this case will need to move Mobile to new and dedicated vPar to segregate from CRM environment.
• And will have a downtime (3-6 hour estimated) in current mobile environment.
• Note: a second downtime will be needed to add HW to the BW-LSA/MI nPAR after it is released from BI.
• Estimate is aproximately 2 hours. (See slide from BPC).
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Impact of CRM on the IP
© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.35
Impact of SRM on the PI1. PI is currently running stacked with GRC on a SD-2 partition. Below is the current nPar config:
This means that the current nPar supports ~5,000 SAPS, and can support ~10,000 SAPS after the activation of the 4 iCAP cores;
2. Additional interfaces will be added to the PI system as part of the SRM implementation. The table below summarizes the requirements to handle these new interfaces:
3. We considerate a 3-tier PI deployment, with the PI APP servers running on HP-UX, we can assume that the current nPar can support current PI + GRC + new interfaces, after the activation of the iCAP cores:
• GRC Phase 2 DB: 6,400 SAPS
• Current PI: SAPS (assuming 2,000 SAPS)
• New interfaces: 1000 SAPS
• Total: ~9,400 SAPS (ok on the 8-way nPar, but will be use 04 cores ICAPed, and add new SAP Dialog instances for PP0, in
vnlux003, vnlux010 and cavavs08);4. The cost of this expansion of PI (04 cores ICAPed and new SAP Dialog) is not included in
this project;
SAP Application SCC PROD Sids MCC PRE-PROD Sids Blade total proc total cores sized
Phase1 cores ACTIVE cores iCAPed ramPI/GRC-NFE PP0/NP0 PR0/NR0 1 2 4 4 4 128
Release SAPS (total) Memory (GB)PI 7.1 5,200 42