uv angel air · uv angel and . 888.277.2596 • ifuvael.cm • uvael.cm uv angel air are registered...

7
UV ANGEL AIR INSTALLATION AND OPERATING INSTRUCTIONS Version 14 | 07.29.20

Upload: others

Post on 25-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: UV ANGEL AIR · UV Angel and . 888.277.2596 • IFUVAEL.CM • UVAEL.CM UV Angel Air are registered trademarks o UV Partners, Inc. The UV lamp is rated for 9000 hours of continuous

UV ANGEL AIR™

INSTALLATION AND OPERATING INSTRUCTIONS

Version 14 | 07.29.20

Page 2: UV ANGEL AIR · UV Angel and . 888.277.2596 • IFUVAEL.CM • UVAEL.CM UV Angel Air are registered trademarks o UV Partners, Inc. The UV lamp is rated for 9000 hours of continuous

888.277.2596 • [email protected] • UVANGEL.COMCopyright UV Partners, Inc. All rights reserved. UV Angel® and UV Angel Air® are registered trademarks of UV Partners, Inc.

UV ANGEL AIR OPERATION AND INSTALLATION

)IRECTIONS FOR USE

No Downlight (2x4) Weight: 23.25 lbsLength: 47.75” Width: 23.8” Depth: 3.94”

Important Safety Instructions

WARNING: This fi xture must be grounded and installed in accordance with local and national electrical codes, by a person familiar with construction and operation of the product and the hazards involved. Manufacturer assumes no responsibility for the improper installation or application of this fixture .

WARNING: Fixture contains high intensity UV light for air treatment. Always wear eye protection when servicing. Turn off unit / disconnect before servicing.

CAUTION

• Remove fi xture from carton with care to avoid possible cuts and abrasions from raw edges. It is recommended towear cut-resistance installation gloves while handling and installing. Please read complete detailed installationinstructions enclosed prior to installation.

• Risk of burn. Disconnect power and allow fi xture to cool before changing bulb or handling fi xture.• Notice: Green ground screw provided in proper location. Do not relocate.• Notice: Lamps contain mercury, dispose according to local, state, or federal laws.

+ For more information, visit: www.lamprecycle.org.• Do not use outdoors.• Do not use equipment for other than its intended use.• The use of accessory equipment not specifi ed by UV Angel is not recommended and may cause an unsafe

condition. Read this entire document.

UV engine power requirements: 110-277V AC, nominal 95 watts + 20 watts of fans = 115 W total, 1A

• 347v for Canada is available, 0.41A total

LED downlighting power requirements: 120-277 VAC, 0.5A, 50W max.

• 347v for Canada is available, 0.35A total, 54W max., 0.18A

Power Ratings

Downlight (2x4) Weight: 26 lbsLength: 47.75” Width: 23.8” Depth: 3.94”

Packing ContentsFixture housing (2x4

Models Shown)

Installation Instructions

1. Install the UV Angel Air into ceiling.2. Green light means unit is working correctly; if the green light is not lit, contact the UV Angel team for support. 3. Replace UV lamp and filter annually.

meredithjimenez
Sticky Note
Add the link to the installation video
Page 3: UV ANGEL AIR · UV Angel and . 888.277.2596 • IFUVAEL.CM • UVAEL.CM UV Angel Air are registered trademarks o UV Partners, Inc. The UV lamp is rated for 9000 hours of continuous

888.277.2596 • [email protected] • UVANGEL.COMCopyright UV Partners, Inc. All rights reserved. UV Angel® and UV Angel Air® are registered trademarks of UV Partners, Inc.

Installation InstructionsEnvironmentNOTICE: The UV Angel AirTM system is to be operated indoors, in a temperature and humidity-controlled environment between 68-122°F and 20-80% humidity.

Drop Ceiling Grid-Lock Feature

1. The UV Angel AirTM installs like a standard lay in trofferwith the added feature of our gridlock system toensure it stays fi rmly in place. Where required, the unitshould be tethered to a secure anchor point that iscapable of supporting the fi xture’s weight in the ceiling(Fig. 1a).

a. Downlight 100-1095: 26 lbs.b. No Downlight 100-1158: 23.5 lbs.Note: Use minimum of (2) #12 wires at diagonal corners.

2. The grid lock feature is built into the housing. Bendthe tab 90 degrees, lay the fi xture into the grid, androtate either way until it engages with the T-grid. Thereis no need to open the fi xture to use this feature (Fig. 1b).

3. Bend by hand to engage T-Grid on all (4) corners.a. NOTICE: Clips are intended to be used forsecuring to NEMA Type-G Recessed Fixtures.

4. Facility installing contractor shall hang, secure andmount air treatment system units per the local and /or state codes and standards.

5. The air unit fi ts standard 9/16”, 15/16” and 1” acoustical ceiling grids (fi neline,architectural and commercial types).

6. Air unit will also recess into standard drywall frame kit. The supply and installationand support of drywall frame kit shall be responsibility of air unit installing contractor.support shall be done to meet all state and local codes/ordinances.

7. Hard ceiling SURFACE mount kit will be available by UV Angel in near future pendingUL/ETL testing.

FIGURE 1a

Main Tee

Cross Tee

Supplementary hanger wires to the supporting tee location within three inches of the corner of the fi xture

16 lb./ft. 4’ Cross tee or supplementary hanger wires as shown for cross tees with load capacities below 16 lbs./ft.

2’ x 4’ Fixture

FIGURE 1b

Page 4: UV ANGEL AIR · UV Angel and . 888.277.2596 • IFUVAEL.CM • UVAEL.CM UV Angel Air are registered trademarks o UV Partners, Inc. The UV lamp is rated for 9000 hours of continuous

888.277.2596 • [email protected] • UVANGEL.COMCopyright UV Partners, Inc. All rights reserved. UV Angel® and UV Angel Air® are registered trademarks of UV Partners, Inc.

Hard Ceiling Surface Mount

1. Remove the C-Frame, two endcaps and hardwarebags from the box.

2. Installing contractor is responsible for all mountingfasteners and hanging hardware. Wood screws,washers, toggle bolts, or suspension hardware shouldbe sized to support a minimum of 60 lbs. Use (6) holesto secure Surface Mounting Kit to the ceiling surface.Contractor to support per local and state buildingcodes.

3. If power will be coming from the top of the standardair unit, knockout appropriate holes on C-Frame (outlined in adiamond in Figure 2).

4. Locate the holes for ceiling mounting on C-Frame. There are threeoptions of holes to choose from, see Figure 2. One option is forhanging/suspension, shown with a rectangle shape around it. Twooptions are for lagging/screwing, shown with triangles and circlesaround the holes

5. Orient the C-Frame so that the pivot pins are on the side that powerwill be supplied from. Installing contractor should properly mountC-Frame to ceiling using appropriate hardware (Figure 3)

6. Move standard UV Angel Air Unit to C-Frame so that the slotted cuthooks onto the pivot pins. Be sure the side of the Air Unit with poweris nearest to the pivot pins. (Figure 4)

7. Leave system hanging down to perform step seven.

8. See Wiring Fixture section of this manual to wire the UV Angel AirUnit. Install in accordance to NEC, ANSI/NFPA 70 & local codes.

9. Swing Air Unit up into the C-Frame. With the two provided #8-32 x½” machine screws, secure the non-hinged end using holes on thelong sides of the C-Frame. Keep screws torque loose.

10. With the four provided #8-32 x ½” machine screws, secure the longsides of the of the C-Frame. Tighten all 6 screws. Do not over tighten.

11. Attach end-cap with slot to the end of the Air Unit where power issupplied using four #8 x 3/8” sheet metal screws.

12. Attach the other end-cap to the other side using the four remaining#8 x 3/8” sheet metal screws

13. Tighten all fasteners.

FIGURE 2: C-Frame back. Each shape represents a different set of holes. Diamond denotes knockout holes

FIGURE 3: Total Assembly Exploded View

FIGURE 4: C-Frame/Air Unit Interaction

Page 5: UV ANGEL AIR · UV Angel and . 888.277.2596 • IFUVAEL.CM • UVAEL.CM UV Angel Air are registered trademarks o UV Partners, Inc. The UV lamp is rated for 9000 hours of continuous

888.277.2596 • [email protected] • UVANGEL.COMCopyright UV Partners, Inc. All rights reserved. UV Angel® and UV Angel Air® are registered trademarks of UV Partners, Inc.

Wiring Fixture

1. Wiring must comply with all applicable electrical codes.

2. Turn off power before installing wiring.

3. Strip incoming power wire to 11mm

4. Remove access plate from backside of fi xture

5. Remove K.O. access plate.

6. Add an approved twin screw cable clamp connector orconduit connector into the K.O. hole before feedingin wires.

7. Insert wires into removed K.O. hole. Take groundwire and wrap it around head of green ground screwprovided in frame. This wire should be wrappedcounter-clockwise (Fig. 5). Tighten screw to secure this wire. NOTICE:GROUND SCREW PROVIDED ON FRAME UNDER ACCESS PLATE.

8. Locate the UV ballast linear disconnect (brown conductor) connectorwithin fi xture.

9. Grip black supply wire fi rmly and pushconductor into port marked with blackrectangle and #1 (Fig. 6*).

10. Grip white supply wire fi rmly and pushconductor into port marked with whiterectangle and #2.

11. Use only one conductor per port and assurethat no copper is exposed on inserted wires.

12. WIRING FOR LED DOWNLIGHT 100-1095:Repeat steps 7 through 10 connectingincoming power for downlight to the LED lineardisconnect (black conductor). Downlight can bewired to switch or constant supply voltage. UVLamp should always be connected to constantsupply voltage for best cleaning results.NOTICE: The wire insertion side of this productis listed for ONE TIME USE ONLY. DO NOTREMOVE.

13. Re-attach access plate to fi xture.

UV Ballast Linear Disconnect

GROUND

LED Downlight Linear Disconnect

FIGURE 5

FIGURE 6

*For more information please refer to WAGO PN: 873-902

Page 6: UV ANGEL AIR · UV Angel and . 888.277.2596 • IFUVAEL.CM • UVAEL.CM UV Angel Air are registered trademarks o UV Partners, Inc. The UV lamp is rated for 9000 hours of continuous

888.277.2596 • [email protected] • UVANGEL.COMCopyright UV Partners, Inc. All rights reserved. UV Angel® and UV Angel Air® are registered trademarks of UV Partners, Inc.

First time UV Lamp installation

1. Follow instructions above to open chamber access door located on room-sideto access 2G11 socket.

2. Carefully unbox lamp and install into 2G11 socket and retention clip.NOTICE: Use clean, cloth gloves to install the UV lamps. Oil from fi ngers willpermanently etch glass of lamp and weaken structure and damage to lampwill result. Clean lamp with rubbing alcohol and clean cloth if necessary.

3. Close and latch UV-C chamber door

4. Close and latch fi lter door after the chamber door is secured

5. Turn on power and confi rm panel LED is green (Fig. 7)

NOTICE: Cleaning panel door must be closed prior to fi lter door which is located Both doors contain safety switches to disable power to UV lamp and fans.

For further installation instructions see: Bulb & fi lter replacement kit: P/N 100-1097

Service Instructions

6. To service fi lter/fans, open the fi lter door latch with fi ngers or paint-safe tool(Fig. 8).

+ Replace fi lter according to instructions in bulb & fi lter replacement kit: P/N100-1097

7. To service UV lamp, open cleaning panel door latch with fi ngers or paint- safe tool.+ NOTICE: Filter door must be opened prior to cleaning panel door+ Replace lamp according to instructions in bulb & fi lter replacement kit:

P/N 100-1097+ Dispose of used UV-C lamp at local or state-run hazardous waste disposal

facility, with a universal waste handler, or an authorized recycling facility.

FIGURE 7

FIGURE 8

UV Lamp/Filter Installation Maintenance

Page 7: UV ANGEL AIR · UV Angel and . 888.277.2596 • IFUVAEL.CM • UVAEL.CM UV Angel Air are registered trademarks o UV Partners, Inc. The UV lamp is rated for 9000 hours of continuous

888.277.2596 • [email protected] • UVANGEL.COMCopyright UV Partners, Inc. All rights reserved. UV Angel® and UV Angel Air® are registered trademarks of UV Partners, Inc.

The UV lamp is rated for 9000 hours of continuous use so we recommend changing it annually. The MERV 6 filter should be changed annually. The maintenance of all UV Angel products is designed to be as simple as possible.

UV-C Lamp: Using a stepladder, open the grill door under the unit by unlatching and moving the hinges down. Open the large door panel (this will either be the Lighting Edgelight panel or a solid metal panel). The unlatched, open grill door, and door panel cuts power off to the fans and the UV-C lamp. Using gloves and protective eyewear, remove the UV-C lamp from the socket. Remove the new bulb from box and insert it into the socket. Close both doors, starting with the large door panel followed by the grill door. Latch tightly. Once the green light illuminates, the UV-C light will turn on and the fans restart. Safely dispose of the used UV-C lamp.

Filter: Open the grill door by unlatching and moving the hinges down. Using gloves and protective eyewear, grab the black tabs on the filter. Remove the filter by pushing in and then pulling down. Take the new filter and insert the non-tab side into the fan/filter frame and then push the tab side up so that it fits within the frame. Close by re-latching the grill door. The fan and UV-C light will resume operation. Safely dispose of the used filter.

If you experience an issue with your UV Angel Air product, please contact our team at 888-277-2596 or email us at [email protected] for troubleshooting assistance or help with ordering a replacement part.

Maintenance

EPA Est. No. 95756-GA-1 UV ANGEL

233 Washington Ave., Suite L1, Grand Haven, MI, 49417