Page 1: Using VDSL2 over Copper in the Vertical String

Peter Jansweijer et al. Slide 1VLVnT08 ToulonApril 23, 2008

Using VDSL2 over Copperin the Vertical String

Page 2: Using VDSL2 over Copper in the Vertical String

Peter Jansweijer et al. Slide 2VLVnT08 ToulonApril 23, 2008

Copper, a traditional viewSerial Link

• Dispersion• High Frequency Attenuation

‘0’ and ‘1’ are transmitted as pulses

Depending on transmission speed, this will only work for a limited distance of twisted pair due to:

Page 3: Using VDSL2 over Copper in the Vertical String

Peter Jansweijer et al. Slide 3VLVnT08 ToulonApril 23, 2008

ADSL, ADSL2, ADLS2plusAsymmetric Digital Subscriber Line

VDSL, VDSL2Very high speed Digital Subscriber Line

Want to provide “Triple Play”(Voice, Video, Data)

OpticalNetworkUnit

CopperDSL

OpticalLineTerminal

Fiber

OpticalDistributionNetwork

OpticalNetworkTerminal

Telecommunications Industry

Today, most subscribers are connected via copper

Replacing copper by fiber is a major investment

Page 4: Using VDSL2 over Copper in the Vertical String

Peter Jansweijer et al. Slide 4VLVnT08 ToulonApril 23, 2008

Bandwidth up + down stream total: 200 Mbps

25 KHz – 30 MHz

VDSL2

Source:http://www.infineon.com//upload/Document/VDSL2_WP_072005_v1.1.pdf

500 Meter VDSL2:100 Mbps downstream10 Mbps upstream

Rate/Reach Performance

Page 5: Using VDSL2 over Copper in the Vertical String

Peter Jansweijer et al. Slide 5VLVnT08 ToulonApril 23, 2008

ADSL / VDSLOFDM Orthogonal Frequency Division Multiplexing

Frequency

Am

pli

tud

e

Page 6: Using VDSL2 over Copper in the Vertical String

Peter Jansweijer et al. Slide 6VLVnT08 ToulonApril 23, 2008

ADSL / VDSL

All intelligence in a single chip:

Page 7: Using VDSL2 over Copper in the Vertical String

Peter Jansweijer et al. Slide 7VLVnT08 ToulonApril 23, 2008

Vertical String Architecture

OpticalModule

OpticalModule

OpticalModule

MasterModule

Fiber

~ 5

00 M

tr

100 Mbps

10 Mbps

Estimated Bandwidth:

• 20 Mbps per Optical Module

One Single Twisted Pair per Optical Module:• Bi-directional Data Transport• DC - Power

• Packet overhead and safety factor 5 100 Mbps per Optical Module

• 24 Optical Modules per Vertical String 2.4 Gbps <=

3.1625 Gbps

one / Vertical Stringin a DWDM system

Page 8: Using VDSL2 over Copper in the Vertical String

Peter Jansweijer et al. Slide 8VLVnT08 ToulonApril 23, 2008

VDSL does not have a fixed latency

Are all problems solved?

Store and Forward Data Acquisition System

Create a Time Stamp at the origin of an Event

Need a Local Clock in each Optical Module

Synchronous

Timing Calibration

How?Calibrated

Page 9: Using VDSL2 over Copper in the Vertical String

Peter Jansweijer et al. Slide 9VLVnT08 ToulonApril 23, 2008

Timing Calibration Over CopperTake a carrier above the VDSL2 Bandwidth (> 30 MHz)

Time /

Length

Synchronous: Local Clock is Phase locked to Shore Station

MasterModule

ModulatedMaster Module

Carrier

Calibrationsignal

Length = ‘n’ * TCarrierPeriod + Phase Difference

-Phase

Calibration: OpticalModule

Page 10: Using VDSL2 over Copper in the Vertical String

Peter Jansweijer et al. Slide 10VLVnT08 ToulonApril 23, 2008

Branch Cable

OM

JunctionBox A

MasterModule

TXa RXb

RXa TXb

OM

ab

OM

OM

OM

MasterModule

OM

ab

OM

OM

JunctionBox B

Add & Drop Multiplexer

Redundancy

Page 11: Using VDSL2 over Copper in the Vertical String

Peter Jansweijer et al. Slide 11VLVnT08 ToulonApril 23, 2008

Telescope Overview

ShoreStation

JunctionBox B

JunctionBox A

Branch Cable2 DWDM fibers + Copper (Power)

Master Module ofa Vertical String

2 Long distanceElectro/Optical Cables

16 DWDM Fibers + Copper (Power)

Page 12: Using VDSL2 over Copper in the Vertical String

Peter Jansweijer et al. Slide 12VLVnT08 ToulonApril 23, 2008

Summary

VDSL2 is a cost effective, high bandwidth solution for aVertical String

Need extra functionality to incorporate timingover Copper

Power, Data, Timing over a single twisted Pair

Just one / Vertical String

Need extra functionality to couple timing calibrationover Copper <-> timing over fiber

Total telescope can be read out via 16 DWDM fibers

Telescope

Vertical String

Page 13: Using VDSL2 over Copper in the Vertical String

Peter Jansweijer et al. Slide 13VLVnT08 ToulonApril 23, 2008

Thank you