usg donn® brand ax™/axce™ 15-16'' acoustical … · 2 8 5 4 5 4 5 4 9 3 1 125 7 5 7...

10
2 8 5 4 5 4 5 4 9 3 1 12 5 7 5 7 10 9 11 1 7 4 Scale: 6" = 1'-0" FULL CEILING PANEL W/ CHANNEL WALL MOLDING 4 AX GRID - SL EDGE (CAST) - MAIN TEE ELEVATION Scale: 6" = 1'-0" PANEL AND GRID SECTION CUT THROUGH MAIN TEE 2 AX GRID - SL EDGE (CAST) - CROSS TEE ELEVATION Scale: 6" = 1'-0" FULL CEILING PANEL WITH WALL ANGLE 1 AX GRID - SL EDGE (CAST) - CROSS TEE ELEVATION Scale: 6" = 1'-0" FIELD-CUT GRID AND PANEL AT CHANNEL MOLDING 6 AX GRID - SL EDGE (CAST) - MAIN TEE ELEVATION Scale: 6" = 1'-0" PANEL AND GRID SECTION CUT THROUGH CROSS TEE 5 AX GRID - SL EDGE (CAST) - MAIN TEE ELEVATION Scale: 6" = 1'-0" FIELD-CUT GRID AND PANEL AT WALL ANGLE 3 AX GRID - SL EDGE (CAST) - CROSS TEE ELEVATION 5 7 2 1 3/8 in [10 mm] 3/8 in [10 mm] 6 6 12 1 USG Corporation 550 West Adams Street Chicago, IL 60661 USA WWW.USG.com T. 800-USG4YOU ISSUE RECORD: REV: DATE: SHEETINFORMATION: DISCLAIMER: THE USG PRODUCT DETAILS CONTAINED HEREIN ARE INTENDED FOR USE AS PRODUCT REFERENCE MATERIAL BY ARCHITECTS, ENGINEERS, OTHER DESIGN PROFESSIONALS, CONTRACTORS, BUILDING CODE OFFICIALS, OR OTHER COMPETENT CONSTRUCTION INDUSTRY TRADE PROFESSIONALS HAVING AN INTEREST IN THE SELECTION, SPECIFICATION AND USE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY AS TECHNICAL SUPPORT INCIDENT TO THE SALE AND USE OF USG PRODUCTS AND NOT INTENDED TO BE A SUBSTITUTE FOR THE DESIGN REVIEW AND APPROVAL OF THE LICENSED DESIGN PROFESSIONALS FOR THE PROJECT. THESE MATERIALS MAY BE PRINTED AND/OR TRANSFERRED ELECTRONICALLY SOLELY AS NEEDED BY THE USER. BECAUSE CAD ELECTRONIC FILES AND BIM (BUILDING INFORMATION MODELING ) FILES CAN BE MODIFIED BY OTHER PARTIES, WITHOUT NOTICE OR INDICATION OF SUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGN PROFESSIONAL. USG SL EDGE AX GRID SC3201 00 19/04/2017 USG BASIC GRID DETAILS (NON SEISMIC) DETALLES BASICOS DEL SISTEMA DE SUSPENSION (SIN RESISTENCIA SISMICA) DÉTAILS DE GRILLE DE PLAFOND DE BASE (SYSTÈME NON SISMIQUE) KEYNOTES - BASIC CEILING DETAILS NOTAS - DETALLES BASICOS DE PLAFON ENLEVEZ L'ATTACHE DE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE. 1 2 4 5 6 7 ATTACH WALL ANGLE AT CEILING PERIMETER. ATTACHEZ ANGLE MURAL AUX PÉRIMÈTRE DU PLAFOND. WALL ANGLE. ANGULO PERIMETRAL. PROFILÉ MURALE. TEE SECUNDARIA. TÉE SECONDAIRE. FIJAR ANGULO PERIMETRAL AL MURO. 8 FIELD-CUT CROSS TEE AT WALL ANGLE. CORTE DE TEE AL ANGULO PERIMETRAL. COUPEZ LE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE. REMOVE CLIP FROM CROSS TEE AT WALL ANGLE. ELIMINAR EL CLIP DE LA TEE SECUNDARIA AL ANGULO PERIMETRAL. CROSS TEE. CEILING PANEL. PANEL DE PLAFON. PANNEAU POUR PLAFOND. HANGER WIRE BY OTHERS. ALAMBRE DE SUSPENSION (COLGANTE) POR OTROS. FIL DE SUSPENTE PAR D´AUTRES. 9 FIELD-CUT EDGE TO MATCH PANEL PROFILE. AJUSTE DE PLAFON PARA ENCAJAR EN EL ANGULO. DÉCOUPEZ LE BORD DU PANNEAU POUR CORRESPONDRE AU PROFIL. 10 REMOVE CLIP FROM MAIN TEE AT WALL ANGLE. ELIMINAR EL CLIP DE LA TEE PRINCIPAL AL ANGULO PERIMETRAL. ENLEVEZ L'ATTACHE DE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE. 12 MAIN TEE. TEE PRINCIPAL. TÉE PRINCIPAL. DISCOURS - DÉTAILS DU PLAFOND DE BASE 3 11 ADDITIONAL NOTES: 1. NOT FOR CONSTRUCTION. NO APTO PARA CONSTRUCCION. NE PAS UTILISER POUR CONSTRUCTION. FIELD-CUT MAIN TEE AT WALL ANGLE. COUPEZ LE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE. CORTE DE TEE PRINCIPAL AL ANGULO PERIMETRAL. CHANNEL WALL MOLDING. MOLDURA CANAL PERIMETRAL PARA MURO. PROFILÉ MURALE EN U.

Upload: ledan

Post on 15-Sep-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

2

8

5

4

5

4

5

4

9

3

1

12 5

7

5

7

10

9

11

1

7

4

Scale: 6" = 1'-0"

FULL CEILING PANEL W/ CHANNEL WALL MOLDING

4

AX GRID - SL EDGE (CAST) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

PANEL AND GRID SECTION CUT THROUGH MAIN TEE

2

AX GRID - SL EDGE (CAST) - CROSS TEE ELEVATION

Scale: 6" = 1'-0"

FULL CEILING PANEL WITH WALL ANGLE

1

AX GRID - SL EDGE (CAST) - CROSS TEE ELEVATION

Scale: 6" = 1'-0"

FIELD-CUT GRID AND PANEL AT CHANNEL MOLDING

6

AX GRID - SL EDGE (CAST) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

PANEL AND GRID SECTION CUT THROUGH CROSS TEE

5

AX GRID - SL EDGE (CAST) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

FIELD-CUT GRID AND PANEL AT WALL ANGLE

3

AX GRID - SL EDGE (CAST) - CROSS TEE ELEVATION

5

7

2

1

3/8 in

[10 mm]

3/8 in

[10 mm]

6

6

12

1

USG Corporation

550 West Adams Street

Chicago, IL 60661 USA

WWW.USG.com

T. 800-USG4YOU

ISSUE RECORD:

REV: DATE:

SHEET INFORMATION:

DISCLAIMER: THE USG PRODUCT DETAILS CONTAINED HEREIN ARE INTENDED FOR USE AS PRODUCT REFERENCE MATERIAL BYARCHITECTS, ENGINEERS, OTHER DESIGN PROFESSIONALS, CONTRACTORS, BUILDING CODE OFFICIALS, OR OTHERCOMPETENT CONSTRUCTION INDUSTRY TRADE PROFESSIONALS HAVING AN INTEREST IN THE SELECTION, SPECIFICATION ANDUSE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY ASTECHNICAL SUPPORT INCIDENT TO THE SALE AND USE OF USG PRODUCTS AND NOT INTENDED TO BE A SUBSTITUTE FOR THEDESIGN REVIEW AND APPROVAL OF THE LICENSED DESIGN PROFESSIONALS FOR THE PROJECT. THESE MATERIALS MAY BEPRINTED AND/OR TRANSFERRED ELECTRONICALLY SOLELY AS NEEDED BY THE USER. BECAUSE CAD ELECTRONIC FILES ANDBIM (BUILDING INFORMATION MODELING ) FILES CAN BE MODIFIED BY OTHER PARTIES, WITHOUT NOTICE OR INDICATION OFSUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGNPROFESSIONAL.

USG SL EDGE

AX GRID

SC3201

00 19/04/2017USG BASIC GRID DETAILS (NON SEISMIC)

DETALLES BASICOS DEL SISTEMA DE SUSPENSION (SIN RESISTENCIA SISMICA)

DÉTAILS DE GRILLE DE PLAFOND DE BASE (SYSTÈME NON SISMIQUE)

KEYNOTES - BASIC CEILING DETAILSNOTAS - DETALLES BASICOS DE PLAFON

ENLEVEZ L'ATTACHE DE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.

1

2

4

5

6

7

ATTACH WALL ANGLE AT CEILING PERIMETER.

ATTACHEZ ANGLE MURAL AUX PÉRIMÈTRE DU PLAFOND.WALL ANGLE.ANGULO PERIMETRAL.PROFILÉ MURALE.

TEE SECUNDARIA.TÉE SECONDAIRE.

FIJAR ANGULO PERIMETRAL AL MURO.

8FIELD-CUT CROSS TEE AT WALL ANGLE.CORTE DE TEE AL ANGULO PERIMETRAL.COUPEZ LE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.

REMOVE CLIP FROM CROSS TEE AT WALL ANGLE.ELIMINAR EL CLIP DE LA TEE SECUNDARIA AL ANGULO PERIMETRAL.

CROSS TEE.

CEILING PANEL.PANEL DE PLAFON.PANNEAU POUR PLAFOND.HANGER WIRE BY OTHERS.ALAMBRE DE SUSPENSION (COLGANTE) POR OTROS.FIL DE SUSPENTE PAR D´AUTRES.

9FIELD-CUT EDGE TO MATCH PANEL PROFILE.AJUSTE DE PLAFON PARA ENCAJAR EN EL ANGULO.DÉCOUPEZ LE BORD DU PANNEAU POUR CORRESPONDRE AU PROFIL.

10

REMOVE CLIP FROM MAIN TEE AT WALL ANGLE.ELIMINAR EL CLIP DE LA TEE PRINCIPAL AL ANGULO PERIMETRAL.ENLEVEZ L'ATTACHE DE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.

12

MAIN TEE.TEE PRINCIPAL.TÉE PRINCIPAL.

DISCOURS - DÉTAILS DU PLAFOND DE BASE

3

11

ADDITIONAL NOTES:

1. NOT FOR CONSTRUCTION.NO APTO PARA CONSTRUCCION.NE PAS UTILISER POUR CONSTRUCTION.

FIELD-CUT MAIN TEE AT WALL ANGLE.

COUPEZ LE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.CORTE DE TEE PRINCIPAL AL ANGULO PERIMETRAL.

CHANNEL WALL MOLDING.MOLDURA CANAL PERIMETRAL PARA MURO.PROFILÉ MURALE EN U.

2

8

5

4

5

4

5

4

9

3

1

7

Scale: 6" = 1'-0"

FULL CEILING PANEL W/ CHANNEL WALL MOLDING

4

AX GRID - SL EDGE (HALCYON) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

PANEL AND GRID SECTION CUT THROUGH MAIN TEE

2

AX GRID - SL EDGE (HALCYON) - CROSS TEE ELEVATION

Scale: 6" = 1'-0"

FULL CEILING PANEL WITH WALL ANGLE

1

AX GRID - SL EDGE (HALCYON) - CROSS TEE ELEVATION

Scale: 6" = 1'-0"

FIELD-CUT GRID AND PANEL AT CHANNEL MOLDING

6

AX GRID - SL EDGE (HALCYON) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

PANEL AND GRID SECTION CUT THROUGH CROSS TEE

5

AX GRID - SL EDGE (HALCYON) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

FIELD-CUT GRID AND PANEL AT WALL ANGLE

3

AX GRID - SL EDGE (HALCYON) - CROSS TEE ELEVATION

2

3/8 in

[10 mm]

3/8 in

[10 mm]

6

12 5

7

5

7

10

9

11

1

45

7

6

12

1

1

USG Corporation

550 West Adams Street

Chicago, IL 60661 USA

WWW.USG.com

T. 800-USG4YOU

ISSUE RECORD:

REV: DATE:

SHEET INFORMATION:

DISCLAIMER: THE USG PRODUCT DETAILS CONTAINED HEREIN ARE INTENDED FOR USE AS PRODUCT REFERENCE MATERIAL BYARCHITECTS, ENGINEERS, OTHER DESIGN PROFESSIONALS, CONTRACTORS, BUILDING CODE OFFICIALS, OR OTHERCOMPETENT CONSTRUCTION INDUSTRY TRADE PROFESSIONALS HAVING AN INTEREST IN THE SELECTION, SPECIFICATION ANDUSE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY ASTECHNICAL SUPPORT INCIDENT TO THE SALE AND USE OF USG PRODUCTS AND NOT INTENDED TO BE A SUBSTITUTE FOR THEDESIGN REVIEW AND APPROVAL OF THE LICENSED DESIGN PROFESSIONALS FOR THE PROJECT. THESE MATERIALS MAY BEPRINTED AND/OR TRANSFERRED ELECTRONICALLY SOLELY AS NEEDED BY THE USER. BECAUSE CAD ELECTRONIC FILES ANDBIM (BUILDING INFORMATION MODELING ) FILES CAN BE MODIFIED BY OTHER PARTIES, WITHOUT NOTICE OR INDICATION OFSUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGNPROFESSIONAL.

USG SL EDGE

AX GRID

SC3202

00 19/04/2017USG BASIC GRID DETAILS (NON SEISMIC)

DETALLES BASICOS DEL SISTEMA DE SUSPENSION (SIN RESISTENCIA SISMICA)

DÉTAILS DE GRILLE DE PLAFOND DE BASE (SYSTÈME NON SISMIQUE)

KEYNOTES - BASIC CEILING DETAILSNOTAS - DETALLES BASICOS DE PLAFON

ENLEVEZ L'ATTACHE DE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.

1

2

4

5

6

7

ATTACH WALL ANGLE AT CEILING PERIMETER.

ATTACHEZ ANGLE MURAL AUX PÉRIMÈTRE DU PLAFOND.WALL ANGLE.ANGULO PERIMETRAL.PROFILÉ MURALE.

TEE SECUNDARIA.TÉE SECONDAIRE.

FIJAR ANGULO PERIMETRAL AL MURO.

8FIELD-CUT CROSS TEE AT WALL ANGLE.CORTE DE TEE AL ANGULO PERIMETRAL.COUPEZ LE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.

REMOVE CLIP FROM CROSS TEE AT WALL ANGLE.ELIMINAR EL CLIP DE LA TEE SECUNDARIA AL ANGULO PERIMETRAL.

CROSS TEE.

CEILING PANEL.PANEL DE PLAFON.PANNEAU POUR PLAFOND.HANGER WIRE BY OTHERS.ALAMBRE DE SUSPENSION (COLGANTE) POR OTROS.FIL DE SUSPENTE PAR D´AUTRES.

9FIELD-CUT EDGE TO MATCH PANEL PROFILE.AJUSTE DE PLAFON PARA ENCAJAR EN EL ANGULO.DÉCOUPEZ LE BORD DU PANNEAU POUR CORRESPONDRE AU PROFIL.

10

REMOVE CLIP FROM MAIN TEE AT WALL ANGLE.ELIMINAR EL CLIP DE LA TEE PRINCIPAL AL ANGULO PERIMETRAL.ENLEVEZ L'ATTACHE DE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.

12

MAIN TEE.TEE PRINCIPAL.TÉE PRINCIPAL.

DISCOURS - DÉTAILS DU PLAFOND DE BASE

3

11

ADDITIONAL NOTES:

1. NOT FOR CONSTRUCTION.NO APTO PARA CONSTRUCCION.NE PAS UTILISER POUR CONSTRUCTION.

FIELD-CUT MAIN TEE AT WALL ANGLE.

COUPEZ LE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.CORTE DE TEE PRINCIPAL AL ANGULO PERIMETRAL.

CHANNEL WALL MOLDING.MOLDURA CANAL PERIMETRAL PARA MURO.PROFILÉ MURALE EN U.

2

8

5

4

5

4

9

3

1

12 5 5

7

4

Scale: 6" = 1'-0"

FULL CEILING PANEL W/ CHANNEL WALL MOLDING

4

AX GRID - SL PE EDGE (PEDESTALS ECLIPSE) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

PANEL AND GRID SECTION CUT THROUGH MAIN TEE

2

AX GRID - SL PE EDGE (PEDESTALS ECLIPSE) - CROSS TEE ELEVATION

Scale: 6" = 1'-0"

FULL CEILING PANEL WITH WALL ANGLE

1

AX GRID - SL PE EDGE (PEDESTALS ECLIPSE) - CROSS TEE ELEVATION

Scale: 6" = 1'-0"

FIELD-CUT GRID AND PANEL AT CHANNEL MOLDING

6

AX GRID - SL PE EDGE (PEDESTALS ECLIPSE) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

PANEL AND GRID SECTION CUT THROUGH CROSS TEE

5

AX GRID - SL PE EDGE (PEDESTALS ECLIPSE) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

FIELD-CUT GRID AND PANEL AT WALL ANGLE

3

AX GRID - SL PE EDGE (PEDESTALS ECLIPSE) - CROSS TEE ELEVATION

5

2

3/8 in

[10 mm]

3/8 in

[10 mm]

6

5

4

7 7

10

9

11

1

7

6

12

1

1

USG Corporation

550 West Adams Street

Chicago, IL 60661 USA

WWW.USG.com

T. 800-USG4YOU

ISSUE RECORD:

REV: DATE:

SHEET INFORMATION:

DISCLAIMER: THE USG PRODUCT DETAILS CONTAINED HEREIN ARE INTENDED FOR USE AS PRODUCT REFERENCE MATERIAL BYARCHITECTS, ENGINEERS, OTHER DESIGN PROFESSIONALS, CONTRACTORS, BUILDING CODE OFFICIALS, OR OTHERCOMPETENT CONSTRUCTION INDUSTRY TRADE PROFESSIONALS HAVING AN INTEREST IN THE SELECTION, SPECIFICATION ANDUSE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY ASTECHNICAL SUPPORT INCIDENT TO THE SALE AND USE OF USG PRODUCTS AND NOT INTENDED TO BE A SUBSTITUTE FOR THEDESIGN REVIEW AND APPROVAL OF THE LICENSED DESIGN PROFESSIONALS FOR THE PROJECT. THESE MATERIALS MAY BEPRINTED AND/OR TRANSFERRED ELECTRONICALLY SOLELY AS NEEDED BY THE USER. BECAUSE CAD ELECTRONIC FILES ANDBIM (BUILDING INFORMATION MODELING ) FILES CAN BE MODIFIED BY OTHER PARTIES, WITHOUT NOTICE OR INDICATION OFSUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGNPROFESSIONAL.

USG SL PEDESTALS EDGE

AX GRID

SC3204

00 19/04/2017USG BASIC GRID DETAILS (NON SEISMIC)

DETALLES BASICOS DEL SISTEMA DE SUSPENSION (SIN RESISTENCIA SISMICA)

DÉTAILS DE GRILLE DE PLAFOND DE BASE (SYSTÈME NON SISMIQUE)

KEYNOTES - BASIC CEILING DETAILSNOTAS - DETALLES BASICOS DE PLAFON

ENLEVEZ L'ATTACHE DE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.

1

2

4

5

6

7

ATTACH WALL ANGLE AT CEILING PERIMETER.

ATTACHEZ ANGLE MURAL AUX PÉRIMÈTRE DU PLAFOND.WALL ANGLE.ANGULO PERIMETRAL.PROFILÉ MURALE.

TEE SECUNDARIA.TÉE SECONDAIRE.

FIJAR ANGULO PERIMETRAL AL MURO.

8FIELD-CUT CROSS TEE AT WALL ANGLE.CORTE DE TEE AL ANGULO PERIMETRAL.COUPEZ LE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.

REMOVE CLIP FROM CROSS TEE AT WALL ANGLE.ELIMINAR EL CLIP DE LA TEE SECUNDARIA AL ANGULO PERIMETRAL.

CROSS TEE.

CEILING PANEL.PANEL DE PLAFON.PANNEAU POUR PLAFOND.HANGER WIRE BY OTHERS.ALAMBRE DE SUSPENSION (COLGANTE) POR OTROS.FIL DE SUSPENTE PAR D´AUTRES.

9FIELD-CUT EDGE TO MATCH PANEL PROFILE.AJUSTE DE PLAFON PARA ENCAJAR EN EL ANGULO.DÉCOUPEZ LE BORD DU PANNEAU POUR CORRESPONDRE AU PROFIL.

10

REMOVE CLIP FROM MAIN TEE AT WALL ANGLE.ELIMINAR EL CLIP DE LA TEE PRINCIPAL AL ANGULO PERIMETRAL.ENLEVEZ L'ATTACHE DE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.

12

MAIN TEE.TEE PRINCIPAL.TÉE PRINCIPAL.

DISCOURS - DÉTAILS DU PLAFOND DE BASE

3

11

ADDITIONAL NOTES:

1. NOT FOR CONSTRUCTION.NO APTO PARA CONSTRUCCION.NE PAS UTILISER POUR CONSTRUCTION.

FIELD-CUT MAIN TEE AT WALL ANGLE.

COUPEZ LE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.CORTE DE TEE PRINCIPAL AL ANGULO PERIMETRAL.

CHANNEL WALL MOLDING.MOLDURA CANAL PERIMETRAL PARA MURO.PROFILÉ MURALE EN U.

2

8

5

4

5

4

9

3

1

12 5 5

7

4

Scale: 6" = 1'-0"

FULL CEILING PANEL W/ CHANNEL WALL MOLDING

4

AX GRID - SLB EDGE (CAST) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

PANEL AND GRID SECTION CUT THROUGH MAIN TEE

2

AX GRID - SLB EDGE (CAST) - CROSS TEE ELEVATION

Scale: 6" = 1'-0"

FULL CEILING PANEL WITH WALL ANGLE

1

AX GRID - SLB EDGE (CAST) - CROSS TEE ELEVATION

Scale: 6" = 1'-0"

FIELD-CUT GRID AND PANEL AT CHANNEL MOLDING

6

AX GRID - SLB EDGE (CAST) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

PANEL AND GRID SECTION CUT THROUGH CROSS TEE

5

AX GRID - SLB EDGE (CAST) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

FIELD-CUT GRID AND PANEL AT WALL ANGLE

3

AX GRID - SLB EDGE (CAST) - CROSS TEE ELEVATION

5

2

3/8 in

[10 mm]

3/8 in

[10 mm]

6

5

4

7 7

10

9

11

1

7

6

12

1

1

USG Corporation

550 West Adams Street

Chicago, IL 60661 USA

WWW.USG.com

T. 800-USG4YOU

ISSUE RECORD:

REV: DATE:

SHEET INFORMATION:

DISCLAIMER: THE USG PRODUCT DETAILS CONTAINED HEREIN ARE INTENDED FOR USE AS PRODUCT REFERENCE MATERIAL BYARCHITECTS, ENGINEERS, OTHER DESIGN PROFESSIONALS, CONTRACTORS, BUILDING CODE OFFICIALS, OR OTHERCOMPETENT CONSTRUCTION INDUSTRY TRADE PROFESSIONALS HAVING AN INTEREST IN THE SELECTION, SPECIFICATION ANDUSE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY ASTECHNICAL SUPPORT INCIDENT TO THE SALE AND USE OF USG PRODUCTS AND NOT INTENDED TO BE A SUBSTITUTE FOR THEDESIGN REVIEW AND APPROVAL OF THE LICENSED DESIGN PROFESSIONALS FOR THE PROJECT. THESE MATERIALS MAY BEPRINTED AND/OR TRANSFERRED ELECTRONICALLY SOLELY AS NEEDED BY THE USER. BECAUSE CAD ELECTRONIC FILES ANDBIM (BUILDING INFORMATION MODELING ) FILES CAN BE MODIFIED BY OTHER PARTIES, WITHOUT NOTICE OR INDICATION OFSUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGNPROFESSIONAL.

USG SLB EDGE

AX GRID

SC3205

00 19/04/2017USG BASIC GRID DETAILS (NON SEISMIC)

DETALLES BASICOS DEL SISTEMA DE SUSPENSION (SIN RESISTENCIA SISMICA)

DÉTAILS DE GRILLE DE PLAFOND DE BASE (SYSTÈME NON SISMIQUE)

KEYNOTES - BASIC CEILING DETAILSNOTAS - DETALLES BASICOS DE PLAFON

ENLEVEZ L'ATTACHE DE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.

1

2

4

5

6

7

ATTACH WALL ANGLE AT CEILING PERIMETER.

ATTACHEZ ANGLE MURAL AUX PÉRIMÈTRE DU PLAFOND.WALL ANGLE.ANGULO PERIMETRAL.PROFILÉ MURALE.

TEE SECUNDARIA.TÉE SECONDAIRE.

FIJAR ANGULO PERIMETRAL AL MURO.

8FIELD-CUT CROSS TEE AT WALL ANGLE.CORTE DE TEE AL ANGULO PERIMETRAL.COUPEZ LE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.

REMOVE CLIP FROM CROSS TEE AT WALL ANGLE.ELIMINAR EL CLIP DE LA TEE SECUNDARIA AL ANGULO PERIMETRAL.

CROSS TEE.

CEILING PANEL.PANEL DE PLAFON.PANNEAU POUR PLAFOND.HANGER WIRE BY OTHERS.ALAMBRE DE SUSPENSION (COLGANTE) POR OTROS.FIL DE SUSPENTE PAR D´AUTRES.

9FIELD-CUT EDGE TO MATCH PANEL PROFILE.AJUSTE DE PLAFON PARA ENCAJAR EN EL ANGULO.DÉCOUPEZ LE BORD DU PANNEAU POUR CORRESPONDRE AU PROFIL.

10

REMOVE CLIP FROM MAIN TEE AT WALL ANGLE.ELIMINAR EL CLIP DE LA TEE PRINCIPAL AL ANGULO PERIMETRAL.ENLEVEZ L'ATTACHE DE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.

12

MAIN TEE.TEE PRINCIPAL.TÉE PRINCIPAL.

DISCOURS - DÉTAILS DU PLAFOND DE BASE

3

11

ADDITIONAL NOTES:

1. NOT FOR CONSTRUCTION.NO APTO PARA CONSTRUCCION.NE PAS UTILISER POUR CONSTRUCTION.

FIELD-CUT MAIN TEE AT WALL ANGLE.

COUPEZ LE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.CORTE DE TEE PRINCIPAL AL ANGULO PERIMETRAL.

CHANNEL WALL MOLDING.MOLDURA CANAL PERIMETRAL PARA MURO.PROFILÉ MURALE EN U.

2

8

5

4

5

4

9

3

1

10 5 5

7

4

Scale: 6" = 1'-0"

FULL CEILING PANEL W/ CHANNEL WALL MOLDING

4

AX GRID - SLT EDGE (WET-FORMED) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

PANEL AND GRID SECTION CUT THROUGH MAIN TEE

2

AX GRID - SLT EDGE (WET-FORMED) - CROSS TEE ELEVATION

Scale: 6" = 1'-0"

FULL CEILING PANEL WITH WALL ANGLE

1

AX GRID - SLT EDGE (WET-FORMED) - CROSS TEE ELEVATION

Scale: 6" = 1'-0"

FIELD-CUT GRID AND PANEL AT CHANNEL MOLDING

6

AX GRID - SLT EDGE (WET-FORMED) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

PANEL AND GRID SECTION CUT THROUGH CROSS TEE

5

AX GRID - SLT EDGE (WET-FORMED) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

FIELD-CUT GRID AND PANEL AT WALL ANGLE

3

AX GRID - SLT EDGE (WET-FORMED) - CROSS TEE ELEVATION

5

2

3/8 in

[10 mm]

3/8 in

[10 mm]

6

5

4

7 7

10

9

11

1

7

6

12

1

1

USG Corporation

550 West Adams Street

Chicago, IL 60661 USA

WWW.USG.com

T. 800-USG4YOU

ISSUE RECORD:

REV: DATE:

SHEET INFORMATION:

DISCLAIMER: THE USG PRODUCT DETAILS CONTAINED HEREIN ARE INTENDED FOR USE AS PRODUCT REFERENCE MATERIAL BYARCHITECTS, ENGINEERS, OTHER DESIGN PROFESSIONALS, CONTRACTORS, BUILDING CODE OFFICIALS, OR OTHERCOMPETENT CONSTRUCTION INDUSTRY TRADE PROFESSIONALS HAVING AN INTEREST IN THE SELECTION, SPECIFICATION ANDUSE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY ASTECHNICAL SUPPORT INCIDENT TO THE SALE AND USE OF USG PRODUCTS AND NOT INTENDED TO BE A SUBSTITUTE FOR THEDESIGN REVIEW AND APPROVAL OF THE LICENSED DESIGN PROFESSIONALS FOR THE PROJECT. THESE MATERIALS MAY BEPRINTED AND/OR TRANSFERRED ELECTRONICALLY SOLELY AS NEEDED BY THE USER. BECAUSE CAD ELECTRONIC FILES ANDBIM (BUILDING INFORMATION MODELING ) FILES CAN BE MODIFIED BY OTHER PARTIES, WITHOUT NOTICE OR INDICATION OFSUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGNPROFESSIONAL.

USG SLT EDGE

AX GRID

SC3206

00 19/04/2017USG BASIC GRID DETAILS (NON SEISMIC)

DETALLES BASICOS DEL SISTEMA DE SUSPENSION (SIN RESISTENCIA SISMICA)

DÉTAILS DE GRILLE DE PLAFOND DE BASE (SYSTÈME NON SISMIQUE)

KEYNOTES - BASIC CEILING DETAILSNOTAS - DETALLES BASICOS DE PLAFON

ENLEVEZ L'ATTACHE DE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.

1

2

4

5

6

7

ATTACH WALL ANGLE AT CEILING PERIMETER.

ATTACHEZ ANGLE MURAL AUX PÉRIMÈTRE DU PLAFOND.WALL ANGLE.ANGULO PERIMETRAL.PROFILÉ MURALE.

TEE SECUNDARIA.TÉE SECONDAIRE.

FIJAR ANGULO PERIMETRAL AL MURO.

8FIELD-CUT CROSS TEE AT WALL ANGLE.CORTE DE TEE AL ANGULO PERIMETRAL.COUPEZ LE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.

REMOVE CLIP FROM CROSS TEE AT WALL ANGLE.ELIMINAR EL CLIP DE LA TEE SECUNDARIA AL ANGULO PERIMETRAL.

CROSS TEE.

CEILING PANEL.PANEL DE PLAFON.PANNEAU POUR PLAFOND.HANGER WIRE BY OTHERS.ALAMBRE DE SUSPENSION (COLGANTE) POR OTROS.FIL DE SUSPENTE PAR D´AUTRES.

9FIELD-CUT EDGE TO MATCH PANEL PROFILE.AJUSTE DE PLAFON PARA ENCAJAR EN EL ANGULO.DÉCOUPEZ LE BORD DU PANNEAU POUR CORRESPONDRE AU PROFIL.

10

REMOVE CLIP FROM MAIN TEE AT WALL ANGLE.ELIMINAR EL CLIP DE LA TEE PRINCIPAL AL ANGULO PERIMETRAL.ENLEVEZ L'ATTACHE DE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.

12

MAIN TEE.TEE PRINCIPAL.TÉE PRINCIPAL.

DISCOURS - DÉTAILS DU PLAFOND DE BASE

3

11

ADDITIONAL NOTES:

1. NOT FOR CONSTRUCTION.NO APTO PARA CONSTRUCCION.NE PAS UTILISER POUR CONSTRUCTION.

FIELD-CUT MAIN TEE AT WALL ANGLE.

COUPEZ LE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.CORTE DE TEE PRINCIPAL AL ANGULO PERIMETRAL.

CHANNEL WALL MOLDING.MOLDURA CANAL PERIMETRAL PARA MURO.PROFILÉ MURALE EN U.

2

8

5

4

5

4

9

3

1

12 5 5

7

4

Scale: 6" = 1'-0"

FULL CEILING PANEL W/ CHANNEL WALL MOLDING

4

AX GRID - SLT EDGE (ECLIPSE, MARS, MILLENNIA) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

PANEL AND GRID SECTION CUT THROUGH MAIN TEE

2

AX GRID - SLT EDGE (ECLIPSE, MARS, MILLENNIA) - CROSS TEE ELEVATION

Scale: 6" = 1'-0"

FULL CEILING PANEL WITH WALL ANGLE

1

AX GRID - SLT EDGE (ECLIPSE, MARS, MILLENNIA) - CROSS TEE ELEVATION

Scale: 6" = 1'-0"

FIELD-CUT GRID AND PANEL AT CHANNEL MOLDING

6

AX GRID - SLT EDGE (ECLIPSE, MARS, MILLENNIA) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

PANEL AND GRID SECTION CUT THROUGH CROSS TEE

5

AX GRID - SLT EDGE (ECLIPSE, MARS, MILLENNIA) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

FIELD-CUT GRID AND PANEL AT WALL ANGLE

3

AX GRID - SLT EDGE (ECLIPSE, MARS, MILLENNIA) - CROSS TEE ELEVATION

5

2

3/8 in

[10 mm]

3/8 in

[10 mm]

6

5

4

7 7

10

9

11

1

7

6

12

1

1

USG Corporation

550 West Adams Street

Chicago, IL 60661 USA

WWW.USG.com

T. 800-USG4YOU

ISSUE RECORD:

REV: DATE:

SHEET INFORMATION:

DISCLAIMER: THE USG PRODUCT DETAILS CONTAINED HEREIN ARE INTENDED FOR USE AS PRODUCT REFERENCE MATERIAL BYARCHITECTS, ENGINEERS, OTHER DESIGN PROFESSIONALS, CONTRACTORS, BUILDING CODE OFFICIALS, OR OTHERCOMPETENT CONSTRUCTION INDUSTRY TRADE PROFESSIONALS HAVING AN INTEREST IN THE SELECTION, SPECIFICATION ANDUSE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY ASTECHNICAL SUPPORT INCIDENT TO THE SALE AND USE OF USG PRODUCTS AND NOT INTENDED TO BE A SUBSTITUTE FOR THEDESIGN REVIEW AND APPROVAL OF THE LICENSED DESIGN PROFESSIONALS FOR THE PROJECT. THESE MATERIALS MAY BEPRINTED AND/OR TRANSFERRED ELECTRONICALLY SOLELY AS NEEDED BY THE USER. BECAUSE CAD ELECTRONIC FILES ANDBIM (BUILDING INFORMATION MODELING ) FILES CAN BE MODIFIED BY OTHER PARTIES, WITHOUT NOTICE OR INDICATION OFSUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGNPROFESSIONAL.

USG SLT EDGE

AX GRID

SC3207

00 19/04/2017USG BASIC GRID DETAILS (NON SEISMIC)

DETALLES BASICOS DEL SISTEMA DE SUSPENSION (SIN RESISTENCIA SISMICA)

DÉTAILS DE GRILLE DE PLAFOND DE BASE (SYSTÈME NON SISMIQUE)

KEYNOTES - BASIC CEILING DETAILSNOTAS - DETALLES BASICOS DE PLAFON

ENLEVEZ L'ATTACHE DE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.

1

2

4

5

6

7

ATTACH WALL ANGLE AT CEILING PERIMETER.

ATTACHEZ ANGLE MURAL AUX PÉRIMÈTRE DU PLAFOND.WALL ANGLE.ANGULO PERIMETRAL.PROFILÉ MURALE.

TEE SECUNDARIA.TÉE SECONDAIRE.

FIJAR ANGULO PERIMETRAL AL MURO.

8FIELD-CUT CROSS TEE AT WALL ANGLE.CORTE DE TEE AL ANGULO PERIMETRAL.COUPEZ LE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.

REMOVE CLIP FROM CROSS TEE AT WALL ANGLE.ELIMINAR EL CLIP DE LA TEE SECUNDARIA AL ANGULO PERIMETRAL.

CROSS TEE.

CEILING PANEL.PANEL DE PLAFON.PANNEAU POUR PLAFOND.HANGER WIRE BY OTHERS.ALAMBRE DE SUSPENSION (COLGANTE) POR OTROS.FIL DE SUSPENTE PAR D´AUTRES.

9FIELD-CUT EDGE TO MATCH PANEL PROFILE.AJUSTE DE PLAFON PARA ENCAJAR EN EL ANGULO.DÉCOUPEZ LE BORD DU PANNEAU POUR CORRESPONDRE AU PROFIL.

10

REMOVE CLIP FROM MAIN TEE AT WALL ANGLE.ELIMINAR EL CLIP DE LA TEE PRINCIPAL AL ANGULO PERIMETRAL.ENLEVEZ L'ATTACHE DE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.

12

MAIN TEE.TEE PRINCIPAL.TÉE PRINCIPAL.

DISCOURS - DÉTAILS DU PLAFOND DE BASE

3

11

ADDITIONAL NOTES:

1. NOT FOR CONSTRUCTION.NO APTO PARA CONSTRUCCION.NE PAS UTILISER POUR CONSTRUCTION.

FIELD-CUT MAIN TEE AT WALL ANGLE.

COUPEZ LE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.CORTE DE TEE PRINCIPAL AL ANGULO PERIMETRAL.

CHANNEL WALL MOLDING.MOLDURA CANAL PERIMETRAL PARA MURO.PROFILÉ MURALE EN U.

2

8

5

4

5

4

5

4

9

3

1

12 5 5

7

4

Scale: 6" = 1'-0"

FULL CEILING PANEL W/ CHANNEL WALL MOLDING

4

AX GRID - SLT ILLUSION (ECLIPSE, MILLENNIA) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

PANEL AND GRID SECTION CUT THROUGH MAIN TEE

2

AX GRID - SLT ILLUSION (ECLIPSE, MILLENNIA) - CROSS TEE ELEVATION

Scale: 6" = 1'-0"

FULL CEILING PANEL WITH WALL ANGLE

1

AX GRID - SLT ILLUSION (ECLIPSE, MILLENNIA) - CROSS TEE ELEVATION

Scale: 6" = 1'-0"

FIELD-CUT GRID AND PANEL AT CHANNEL MOLDING

6

AX GRID - SLT ILLUSION (ECLIPSE, MILLENNIA) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

PANEL AND GRID SECTION CUT THROUGH CROSS TEE

5

AX GRID - SLT ILLUSION (ECLIPSE, MILLENNIA) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

FIELD-CUT GRID AND PANEL AT WALL ANGLE

3

AX GRID - SLT ILLUSION (ECLIPSE, MILLENNIA) - CROSS TEE ELEVATION

5

2

3/8 in

[10 mm]

3/8 in

[10 mm]

6

7 7

10

9

11

1

7

6

12

1

1

USG Corporation

550 West Adams Street

Chicago, IL 60661 USA

WWW.USG.com

T. 800-USG4YOU

ISSUE RECORD:

REV: DATE:

SHEET INFORMATION:

DISCLAIMER: THE USG PRODUCT DETAILS CONTAINED HEREIN ARE INTENDED FOR USE AS PRODUCT REFERENCE MATERIAL BYARCHITECTS, ENGINEERS, OTHER DESIGN PROFESSIONALS, CONTRACTORS, BUILDING CODE OFFICIALS, OR OTHERCOMPETENT CONSTRUCTION INDUSTRY TRADE PROFESSIONALS HAVING AN INTEREST IN THE SELECTION, SPECIFICATION ANDUSE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY ASTECHNICAL SUPPORT INCIDENT TO THE SALE AND USE OF USG PRODUCTS AND NOT INTENDED TO BE A SUBSTITUTE FOR THEDESIGN REVIEW AND APPROVAL OF THE LICENSED DESIGN PROFESSIONALS FOR THE PROJECT. THESE MATERIALS MAY BEPRINTED AND/OR TRANSFERRED ELECTRONICALLY SOLELY AS NEEDED BY THE USER. BECAUSE CAD ELECTRONIC FILES ANDBIM (BUILDING INFORMATION MODELING ) FILES CAN BE MODIFIED BY OTHER PARTIES, WITHOUT NOTICE OR INDICATION OFSUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGNPROFESSIONAL.

USG SLT ILLUSIONS EDGE

AX GRID

SC3208

00 19/04/2017USG BASIC GRID DETAILS (NON SEISMIC)

DETALLES BASICOS DEL SISTEMA DE SUSPENSION (SIN RESISTENCIA SISMICA)

DÉTAILS DE GRILLE DE PLAFOND DE BASE (SYSTÈME NON SISMIQUE)

KEYNOTES - BASIC CEILING DETAILSNOTAS - DETALLES BASICOS DE PLAFON

ENLEVEZ L'ATTACHE DE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.

1

2

4

5

6

7

ATTACH WALL ANGLE AT CEILING PERIMETER.

ATTACHEZ ANGLE MURAL AUX PÉRIMÈTRE DU PLAFOND.WALL ANGLE.ANGULO PERIMETRAL.PROFILÉ MURALE.

TEE SECUNDARIA.TÉE SECONDAIRE.

FIJAR ANGULO PERIMETRAL AL MURO.

8FIELD-CUT CROSS TEE AT WALL ANGLE.CORTE DE TEE AL ANGULO PERIMETRAL.COUPEZ LE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.

REMOVE CLIP FROM CROSS TEE AT WALL ANGLE.ELIMINAR EL CLIP DE LA TEE SECUNDARIA AL ANGULO PERIMETRAL.

CROSS TEE.

CEILING PANEL.PANEL DE PLAFON.PANNEAU POUR PLAFOND.HANGER WIRE BY OTHERS.ALAMBRE DE SUSPENSION (COLGANTE) POR OTROS.FIL DE SUSPENTE PAR D´AUTRES.

9FIELD-CUT EDGE TO MATCH PANEL PROFILE.AJUSTE DE PLAFON PARA ENCAJAR EN EL ANGULO.DÉCOUPEZ LE BORD DU PANNEAU POUR CORRESPONDRE AU PROFIL.

10

REMOVE CLIP FROM MAIN TEE AT WALL ANGLE.ELIMINAR EL CLIP DE LA TEE PRINCIPAL AL ANGULO PERIMETRAL.ENLEVEZ L'ATTACHE DE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.

12

MAIN TEE.TEE PRINCIPAL.TÉE PRINCIPAL.

DISCOURS - DÉTAILS DU PLAFOND DE BASE

3

11

ADDITIONAL NOTES:

1. NOT FOR CONSTRUCTION.NO APTO PARA CONSTRUCCION.NE PAS UTILISER POUR CONSTRUCTION.

FIELD-CUT MAIN TEE AT WALL ANGLE.

COUPEZ LE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.CORTE DE TEE PRINCIPAL AL ANGULO PERIMETRAL.

CHANNEL WALL MOLDING.MOLDURA CANAL PERIMETRAL PARA MURO.PROFILÉ MURALE EN U.

2

8

5

4

5

4

5

4

2

3

1

12 5 5

7

4

Scale: 6" = 1'-0"

FULL CEILING PANEL W/ CHANNEL WALL MOLDING

4

AX GRID - SQ EDGE (ALL TILES) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

PANEL AND GRID SECTION CUT THROUGH MAIN TEE

2

AX GRID - SQ EDGE (ALL TILES) - CROSS TEE ELEVATION

Scale: 6" = 1'-0"

FULL CEILING PANEL WITH WALL ANGLE

1

AX GRID - SQ EDGE (ALL TILES) - CROSS TEE ELEVATION

Scale: 6" = 1'-0"

FIELD-CUT GRID AND PANEL AT CHANNEL MOLDING

6

AX GRID - SQ EDGE (ALL TILES) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

PANEL AND GRID SECTION CUT THROUGH CROSS TEE

5

AX GRID - SQ EDGE (ALL TILES) - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

FIELD-CUT GRID AND PANEL AT WALL ANGLE

3

AX GRID - SQ EDGE (ALL TILES) - CROSS TEE ELEVATION

5

9

3/8 in

[10 mm]

3/8 in

[10 mm]

6

7 7

1

12

11

1

7

6

10

9

1

USG Corporation

550 West Adams Street

Chicago, IL 60661 USA

WWW.USG.com

T. 800-USG4YOU

ISSUE RECORD:

REV: DATE:

SHEET INFORMATION:

DISCLAIMER: THE USG PRODUCT DETAILS CONTAINED HEREIN ARE INTENDED FOR USE AS PRODUCT REFERENCE MATERIAL BYARCHITECTS, ENGINEERS, OTHER DESIGN PROFESSIONALS, CONTRACTORS, BUILDING CODE OFFICIALS, OR OTHERCOMPETENT CONSTRUCTION INDUSTRY TRADE PROFESSIONALS HAVING AN INTEREST IN THE SELECTION, SPECIFICATION ANDUSE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY ASTECHNICAL SUPPORT INCIDENT TO THE SALE AND USE OF USG PRODUCTS AND NOT INTENDED TO BE A SUBSTITUTE FOR THEDESIGN REVIEW AND APPROVAL OF THE LICENSED DESIGN PROFESSIONALS FOR THE PROJECT. THESE MATERIALS MAY BEPRINTED AND/OR TRANSFERRED ELECTRONICALLY SOLELY AS NEEDED BY THE USER. BECAUSE CAD ELECTRONIC FILES ANDBIM (BUILDING INFORMATION MODELING ) FILES CAN BE MODIFIED BY OTHER PARTIES, WITHOUT NOTICE OR INDICATION OFSUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGNPROFESSIONAL.

USG SQ EDGE

AX GRID

SC3209

00 19/04/2017USG BASIC GRID DETAILS (NON SEISMIC)

DETALLES BASICOS DEL SISTEMA DE SUSPENSION (SIN RESISTENCIA SISMICA)

DÉTAILS DE GRILLE DE PLAFOND DE BASE (SYSTÈME NON SISMIQUE)

KEYNOTES - BASIC CEILING DETAILSNOTAS - DETALLES BASICOS DE PLAFON

ENLEVEZ L'ATTACHE DE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.

1

2

4

5

6

7

ATTACH WALL ANGLE AT CEILING PERIMETER.

ATTACHEZ ANGLE MURAL AUX PÉRIMÈTRE DU PLAFOND.WALL ANGLE.ANGULO PERIMETRAL.PROFILÉ MURALE.

TEE SECUNDARIA.TÉE SECONDAIRE.

FIJAR ANGULO PERIMETRAL AL MURO.

8FIELD-CUT CROSS TEE AT WALL ANGLE.CORTE DE TEE AL ANGULO PERIMETRAL.COUPEZ LE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.

REMOVE CLIP FROM CROSS TEE AT WALL ANGLE.ELIMINAR EL CLIP DE LA TEE SECUNDARIA AL ANGULO PERIMETRAL.

CROSS TEE.

CEILING PANEL.PANEL DE PLAFON.PANNEAU POUR PLAFOND.HANGER WIRE BY OTHERS.ALAMBRE DE SUSPENSION (COLGANTE) POR OTROS.FIL DE SUSPENTE PAR D´AUTRES.

9

10

REMOVE CLIP FROM MAIN TEE AT WALL ANGLE.ELIMINAR EL CLIP DE LA TEE PRINCIPAL AL ANGULO PERIMETRAL.ENLEVEZ L'ATTACHE DE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.

12

MAIN TEE.TEE PRINCIPAL.TÉE PRINCIPAL.

DISCOURS - DÉTAILS DU PLAFOND DE BASE

3

11

ADDITIONAL NOTES:

1. NOT FOR CONSTRUCTION.NO APTO PARA CONSTRUCCION.NE PAS UTILISER POUR CONSTRUCTION.

FIELD-CUT MAIN TEE AT WALL ANGLE.

COUPEZ LE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.CORTE DE TEE PRINCIPAL AL ANGULO PERIMETRAL.

CHANNEL WALL MOLDING.MOLDURA CANAL PERIMETRAL PARA MURO.PROFILÉ MURALE EN U.

SQUARE-CUT PANEL AT PERIMETER.

PANNEAU À BORD CARRÉ AU PÉRIMÈTRE.AJUSTE EN PLAFON PERIMETRAL.

7

8

6

5

4

2

5

1

1012 1211

3/8 in

[10 mm]

3/8 in

[10 mm]

Scale: 6" = 1'-0"

FULL CEILING PANEL WITH WALL ANGLE

4

AXCE GRID - LAY-IN GYPSUM PANEL - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

PANEL AND GRID SECTION CUT THROUGH MAIN TEE

2

AXCE GRID - LAY-IN GYPSUM PANEL - CROSS TEE ELEVATION

Scale: 6" = 1'-0"

FULL CEILING PANEL WITH WALL ANGLE

1

AXCE GRID - LAY-IN GYPSUM PANEL - CROSS TEE ELEVATION

Scale: 6" = 1'-0"

FIELD-CUT GRID AND PANEL AT WALL ANGLE

6

AXCE GRID - LAY-IN GYPSUM PANEL - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

PANEL AND GRID SECTION CUT THROUGH CROSS TEE

5

AXCE GRID - LAY-IN GYPSUM PANEL - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

FIELD-CUT GRID AND PANEL AT WALL ANGLE

3

AXCE GRID - LAY-IN GYPSUM PANEL - CROSS TEE ELEVATION

12

1

9

3 4

2 712

4

7

22

1

9

7 5 74 7

5

1

6

USG Corporation

550 West Adams Street

Chicago, IL 60661 USA

WWW.USG.com

T. 800-USG4YOU

ISSUE RECORD:

REV: DATE:

SHEET INFORMATION:

DISCLAIMER: THE USG PRODUCT DETAILS CONTAINED HEREIN ARE INTENDED FOR USE AS PRODUCT REFERENCE MATERIAL BYARCHITECTS, ENGINEERS, OTHER DESIGN PROFESSIONALS, CONTRACTORS, BUILDING CODE OFFICIALS, OR OTHERCOMPETENT CONSTRUCTION INDUSTRY TRADE PROFESSIONALS HAVING AN INTEREST IN THE SELECTION, SPECIFICATION ANDUSE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY ASTECHNICAL SUPPORT INCIDENT TO THE SALE AND USE OF USG PRODUCTS AND NOT INTENDED TO BE A SUBSTITUTE FOR THEDESIGN REVIEW AND APPROVAL OF THE LICENSED DESIGN PROFESSIONALS FOR THE PROJECT. THESE MATERIALS MAY BEPRINTED AND/OR TRANSFERRED ELECTRONICALLY SOLELY AS NEEDED BY THE USER. BECAUSE CAD ELECTRONIC FILES ANDBIM (BUILDING INFORMATION MODELING ) FILES CAN BE MODIFIED BY OTHER PARTIES, WITHOUT NOTICE OR INDICATION OFSUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGNPROFESSIONAL.

USG LAY-IN GYPSUM PANEL

CLEAN ROOM: AXCE GRID

SC3211

00 19/04/2017USG CLEAN ROOM BASIC CEILING DETAILS (NON SEISMIC)

DETALLES BASICOS PARA CIELO RASOS CLEAN ROOM (SIN RESISTENCIA SISMICA)

DÉTAILS DE BASE POUR SALLE BLANCHE (SYSTÈME NON SISMIQUE)

KEYNOTES - BASIC CEILING DETAILSNOTAS - DETALLES BASICOS DE PLAFON

MAINTAIN GASKET CONTINUITY.MANTENER LA CONTINUIDAD DE LA JUNTA DE ESPUMA CELULAR.ASSURER LE MAINTIEN CONTINUE DU JOINT À MOUSSE ALVÉOLES.

ENLEVEZ L'ATTACHE DE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.

1

2

4

5

6

7

ATTACH WALL ANGLE AT CEILING PERIMETER.

ATTACHEZ ANGLE MURAL AUX PÉRIMÈTRE DU PLAFOND.WALL ANGLE WITH GASKET.ANGULO PERIMETRAL CON JUNTA DE ESPUMA CELULAR.PROFILÉ MURALE AVEC MOUSSE ALVÉOLES.

TEE SECUNDARIA CON JUNTA DE ESPUMA CELULAR.TÉE SECONDAIRE AVEC MOUSSE ALVÉOLES.

FIJAR ANGULO PERIMETRAL AL MURO.

8FIELD-CUT CROSS TEE AT WALL ANGLE.CORTE DE TEE AL ANGULO PERIMETRAL.COUPEZ LE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.

REMOVE CLIP FROM CROSS TEE AT WALL ANGLE.ELIMINAR EL CLIP DE LA TEE SECUNDARIA AL ANGULO PERIMETRAL.

CROSS TEE WITH GASKET.

LAY-IN GYPSUM CEILING PANEL.PANEL PARA CIELO RASO DE TABLERO DE YESO MARCA LAY-IN.PANNEAU DE PLAFOND À POSER SHEETROCK.HANGER WIRE BY OTHERS.ALAMBRE DE SUSPENSION (COLGANTE) POR OTROS.FIL DE SUSPENTE PAR D´AUTRES.

10

REMOVE CLIP FROM MAIN TEE AT WALL ANGLE.ELIMINAR EL CLIP DE LA TEE PRINCIPAL AL ANGULO PERIMETRAL.ENLEVEZ L'ATTACHE DE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.

12MAIN TEE WITH GASKET.TEE PRINCIPAL CON JUNTA DE ESPUMA CELULAR.TÉE PRINCIPAL AVEC MOUSSE ALVÉOLES.

FIELD-CUT MAIN TEE AT WALL ANGLE.

COUPEZ LE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.

ADDITIONAL NOTES:

1. NOT FOR CONSTRUCTION.NO APTO PARA CONSTRUCCION.NE PAS UTILISER POUR CONSTRUCTION.

2. REFERENCE CLEAN ROOM CRITERIA FOR INSTALLATION.REFERENCIA PARA INSTALACION DE CIELOS RASOS CLEAN ROOM.SE REFERRER AUX CRITÈRES D´INSTALLATION POUR SALLE BLANCHE.

DISCOURS - DÉTAILS DU PLAFOND DE BASE

CORTE DE TEE PRINCIPAL AL ANGULO PERIMETRAL.

3

11

9FIELD-CUT EDGE MUST BE SEALED WITH LATEX PAINT.

BORD COUPÉ EN CHANTIER DOIVENT ÊTRE SCELLÉS À L´AIDE DE PEINTURE AU LATEX.BORDE DEL PANEL QUE SE CORTA DEBE SELLARSE CON PINTURA DE LATEX.

8

6

5

4

2

2 13

3/8 in

[10 mm]

3/8 in

[10 mm]

Scale: 6" = 1'-0"

FULL CEILING PANEL WITH WALL ANGLE

4

AXCE GRID - CLEAN ROOM PANEL - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

PANEL AND GRID SECTION CUT THROUGH MAIN TEE

2

AXCE GRID - CLEAN ROOM PANEL - CROSS TEE ELEVATION

Scale: 6" = 1'-0"

FULL CEILING PANEL WITH WALL ANGLE

1

AXCE GRID - CLEAN ROOM PANEL - CROSS TEE ELEVATION

Scale: 6" = 1'-0"

FIELD-CUT GRID AND PANEL AT WALL ANGLE

6

AXCE GRID - CLEAN ROOM PANEL - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

PANEL AND GRID SECTION CUT THROUGH CROSS TEE

5

AXCE GRID - CLEAN ROOM PANEL - MAIN TEE ELEVATION

Scale: 6" = 1'-0"

FIELD-CUT GRID AND PANEL AT WALL ANGLE

3

AXCE GRID - CLEAN ROOM PANEL - CROSS TEE ELEVATION

9

2 14

712

274

7

14

7

1

14

7

11

14

7

5

4

5

12

5

12

9

1

10

6

13

1

3

1

USG Corporation

550 West Adams Street

Chicago, IL 60661 USA

WWW.USG.com

T. 800-USG4YOU

ISSUE RECORD:

REV: DATE:

SHEET INFORMATION:

DISCLAIMER: THE USG PRODUCT DETAILS CONTAINED HEREIN ARE INTENDED FOR USE AS PRODUCT REFERENCE MATERIAL BYARCHITECTS, ENGINEERS, OTHER DESIGN PROFESSIONALS, CONTRACTORS, BUILDING CODE OFFICIALS, OR OTHERCOMPETENT CONSTRUCTION INDUSTRY TRADE PROFESSIONALS HAVING AN INTEREST IN THE SELECTION, SPECIFICATION ANDUSE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY ASTECHNICAL SUPPORT INCIDENT TO THE SALE AND USE OF USG PRODUCTS AND NOT INTENDED TO BE A SUBSTITUTE FOR THEDESIGN REVIEW AND APPROVAL OF THE LICENSED DESIGN PROFESSIONALS FOR THE PROJECT. THESE MATERIALS MAY BEPRINTED AND/OR TRANSFERRED ELECTRONICALLY SOLELY AS NEEDED BY THE USER. BECAUSE CAD ELECTRONIC FILES ANDBIM (BUILDING INFORMATION MODELING ) FILES CAN BE MODIFIED BY OTHER PARTIES, WITHOUT NOTICE OR INDICATION OFSUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGNPROFESSIONAL.

USG CLEAN ROOM PANEL

CLEAN ROOM: AXCE GRID

SC3211

00 19/04/2017USG CLEAN ROOM BASIC CEILING DETAILS (NON SEISMIC)

DETALLES BASICOS PARA CIELO RASOS CLEAN ROOM (SIN RESISTENCIA SISMICA)

DÉTAILS DE BASE POUR SALLE BLANCHE (SYSTÈME NON SISMIQUE)

KEYNOTES - BASIC CEILING DETAILSNOTAS - DETALLES BASICOS DE PLAFON

MAINTAIN GASKET CONTINUITY.MANTENER LA CONTINUIDAD DE LA JUNTA DE ESPUMA CELULAR.ASSURER LE MAINTIEN CONTINUE DU JOINT À MOUSSE ALVÉOLES.

ENLEVEZ L'ATTACHE DE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.

1

2

4

5

6

7

ATTACH WALL ANGLE AT CEILING PERIMETER.

ATTACHEZ ANGLE MURAL AUX PÉRIMÈTRE DU PLAFOND.FIJAR ANGULO PERIMETRAL AL MURO.

8FIELD-CUT CROSS TEE AT WALL ANGLE.CORTE DE TEE AL ANGULO PERIMETRAL.COUPEZ LE TÉE SECONDAIRE À LA JONCTION DU PROFILÉ MURALE.

REMOVE CLIP FROM CROSS TEE AT WALL ANGLE.ELIMINAR EL CLIP DE LA TEE SECUNDARIA AL ANGULO PERIMETRAL.

CLEAN ROOM ACOUSTICAL PANEL.CIELO RASO ACUSTICO CLEAN ROOM.TUILE ACOUSTIQUE CLEAN ROOM.HANGER WIRE BY OTHERS.ALAMBRE DE SUSPENSION (COLGANTE) POR OTROS.FIL DE SUSPENTE PAR D´AUTRES.

10

REMOVE CLIP FROM MAIN TEE AT WALL ANGLE.ELIMINAR EL CLIP DE LA TEE PRINCIPAL AL ANGULO PERIMETRAL.ENLEVEZ L'ATTACHE DE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.

12

13HOLD-DOWN CLIP.CLIP DE RETENCION.AGRAFE DE FIXATION.

14WALL SPRING CLIP.

DISCOURS - DÉTAILS DU PLAFOND DE BASE

3

11

9

WALL ANGLE WITH GASKET.ANGULO PERIMETRAL CON JUNTA DE ESPUMA CELULAR.PROFILÉ MURALE AVEC MOUSSE ALVÉOLES.

TEE SECUNDARIA CON JUNTA DE ESPUMA CELULAR.TÉE SECONDAIRE AVEC MOUSSE ALVÉOLES.

CROSS TEE WITH GASKET.

FIELD-CUT EDGE MAY BE SEALED WITH LATEX PAINT.

BORD COUPÉ EN CHANTIER PEUVENT ÊTRE SCELLÉS À L´AIDE DE PEINTURE AU LATEX.BORDE DEL PANEL QUE SE CORTA SE PUEDE SELLAR CON PINTURA DE LATEX.

FIELD-CUT MAIN TEE AT WALL ANGLE.

COUPEZ LE TÉE PRINCIPAL À LA JONCTION DU PROFILÉ MURALE.CORTE DE TEE PRINCIPAL AL ANGULO PERIMETRAL.

MAIN TEE WITH GASKET.TEE PRINCIPAL CON JUNTA DE ESPUMA CELULAR.TÉE PRINCIPAL AVEC MOUSSE ALVÉOLES.

ADDITIONAL NOTES:

1. NOT FOR CONSTRUCTION.NO APTO PARA CONSTRUCCION.NE PAS UTILISER POUR CONSTRUCTION.

2. REFERENCE CLEAN ROOM CRITERIA FOR INSTALLATION.REFERENCIA PARA INSTALACION DE CIELOS RASOS CLEAN ROOM.SE REFERRER AUX CRITÈRES D´INSTALLATION POUR SALLE BLANCHE.

PINZA SUJETADORA DE PARED.AGRAFE À RESSORT MURALE.