Please carefully and completely read the safety and maintenance instructions before installing the equipment.
WOODEN PLATES: before installing drill Ø 3mm holes in the plates.
A) Drill two fixation holes in each 60mm and 80mm Ø wooden plates. The centre distance between the holes must be parallel to the floor for troublefree fixation of the porcelain elements.
STEP 1 Fixation of the wooden plates and the main insulators
B) Drill three holes in the 100 mm Ø wooden plates to form a up-side-down triangle whose angles are of 60° each (to avoid infringement of the screws of the bases).
Floor
Centre distance
Wooden plate Ø 60 o Ø 80
Floor
A
B
About the manualThis manual was prepared for skilled electricians and service technicians and contains important information as to safety cautions for the installation and service of this equipment.Failure to follow cautious installation practices may cause serious injury to the installer or other persons as well as to the surrounding properties.This manual contains the latest state of technical information at the time when the product first entered the market.Continuous dedication to improve our products require that specifications and design are subject to change without notice.
Please carefully and completely read the safety and maintenance instructionsbefore installing the equipment.
User’s Manual
Glossary
The following terms are used in this manual with the following meaning:
Main insulator: round porcelain piece MUST BE MOUNTED 4 cm away from the wall plate to support and keep the cable well stretched.
Porcelain elements: this includes switches, turn switches, push-buttons, junction boxes and various sockets.Our porcelain elements consist of a base and a cover piece.Porcelain elements are best installed using the special wall plate in order to insulate them from the wall.
Installation
First draw an accurate installation plan and then continue as below:
1 - Fix wooden plates and insulators;2 - Install the electric Tv or/and telephone cable;3 - Fix the porcelain base plates;4 - Strip the insulation of the electrical, Tv and telephone cables;5 - Perform cabling of the various junction boxes and porcelain elements;6 - Bind cables to the insulators;7 - Align the cable;
Important: Make yourself familiar with these instructions before starting the installation.Please duly account for each and every installation step since the very first design stage of the project.If necessary, the personnel assigned to the installation jobs must comply with these instructions and eventually lay out a “safety procedure” in order to assure maximum safety of all persons and compliance with applicable electric rules and laws in the country.
Manufacturer’s liabilityThe manufacturer shall not be hold liable for any of the following events:
• Infringement of the applicable rules and standards in the country of use for electric safety and accidents prevention• Installation errors, incorrect applications of the instructions provided in this manual• Failure to comply with electric power specifications• Modifications or changes without prior manufacturer’s approval• Installation by non-authorized personnel
IMPORTANT: non compliance with these instructions may negatively effect the safety of this material.
Wooden plate Ø 100
INSULATORS: initially, avoid tightening the screws that must be able to rotate during installation.Final tightening can be performed at the end of the installation.
A) Locate the main insulators 4cm away from the rim of each wooden plate;B) Locate the remaining insulators approximately 45 cm but no more than 50 cm away from each other (particularly mind this distance requirement for fixation of horizontal cables)C) For insulators fixation on a bend, preferably use two insulators to form a 45° angle against the wall (see picture below). So, the centre distance between insulators will be 5 cm. (If you use only one insulator, the cable may loosen after a while).
INSTALLATION PATTERNS:
A) Unscrew the cover from the base.
Fixation of the wooden plates and main insulators STEP 1
Start pulling the cable from the top (junction box) to the bottom(turn switch and sockets).
Wooden plate
A B C
4 cm
4 cm
Main insulators
45 cm
45 cm
5 cm
45°
Cable 20 cm
While preparing the necessary wiring cables, make sure to provide 20 cm of cable left from the centre of each wooden plate. This cable length is necessary for later electrical connections and to make pull knots.
B) Take the base in your hands (remember to start from a junction box base).C) Let the cable through the centre of the base
D) place the base in the middle of the wooden plate pulling the cable out (use the provided screws and don’t forget to leave 20 cm cable from the centre of the wooden plate).
Example of a switch and a base
A
B
D
C
STEP 3 Base plates fixation
Installing electric, TV and telephone cables STEP 2
This step provides the necessary length of a silk or cotton piece for step 6.
E
Steel core clamp
B) Take the end of the cable and press the textile to the clamp.
A) Undo the plait down to the clamp.
A
B
Base plates fixation STEP 3 STEP 4 Stripping the insulation from electric, TV and telephone cables
Stripping the insulation from electric,TV and telephone cables STEP 4
C)Make a longitudinal cut in the textile near the clamp.
D) Cut all around the silk/cotton fabric and pull it out of the pvc cable.
C
KEEP the fabric for later cable binding.
If you need to pull the cable through walls or any other kind of surface, strictly use the special porcelain cable entry in order to ensure best insulation.
E) Tighten a clamp down against wall underneath base plate (use a steel core clamp). D
cable entry
A) Provide approximately 10 cm free cable from the clamp in order to avoid problems when screwing the cover down.Wire and connect all porcelain elements and perform functional test before fixing the covers on the base pieces.
A
10 cm
Wiring of the junction boxes and other electric elements STEP 5
Cable binding to the main insulators STEP 6In order to keep the cable tight you need binding (knotting) the cable. After wiring the junction box, bind the nearest main insulator. At this stage and not before you can start binding the cable to the insulators. Perform the knots (marked out in the picture by a different colour) in the same direction as the wooden plate.
perform the knots in the same direction as the wooden plate.
STEP 6 Cable binding to the main insulators
D) Let both fabric pieces obtained before over the cable and do 2 knots. Take up again the edges and tie two knots with them.
A) Slightly loosen the plait to obtain a hole.
A
B) Let the fabric obtained in step 4 through the hole.
B
C) Stretch the double end as shown in the picture.
DC
To do the knots, use the remaining silk fabric obtained in step 4. How to tie the knots:
E) Fit the fabrics into the hole and pull the ends to the knot.
E
FF) Now insert the cable intothe insulator
G) Bind the cable to the opposite main insulator following same procedure.
G
H) Link the remaining insulators.
H I
I) Remove the two remainingfabric pieces.
This is the final result.
Cable bindinge to the main insulators STEP 6 STEP 6 Binding the cable to the main insulators
Important: if there are more than 2 m cable between the two main insulators, do one knot also in the intermediate insulator between two main insulators. This is especially usefull if the cable is layed horizontally.Around a bend always tie two knots between two insulators (using the same colour fabric for improved aesthetics).
Examples of wirings by means of two-porcelain elements.
Now that the cable is fixed to the main insulators and locked by the base plates, you can start aligning the cable. Using item 01200 (offset insulator with screws and dowels) simply align the cable by rotating the insulator around its own screw (the insulator holes are not aligned, they are offset which makes it easy to adjust).Now tighten the fixation screw and your system is finished.
Cable binding to the main insulators STEP 6
Cable alignment STEP 7
Articles
GAMBARELLI
Applicable standards: harmonised standards EN 60669 - 1 and 96 Low voltage CE Directive 73/23 - Italian law provision nr. 626 - 25 - 11- 96
Code00100
Dimensions mmØ 60 - h 67
Porcelain turn-switch 10A 230V
IP 20
Switches and Sockets AccessoriesWooden plates
Ø 60
Ø 80
Code01100
Dimensions mm
Oak wall plate
Ø 60
Ø 80
Code01101
Dimensions mm
Oak round wall plate
Ø 60
Ø 80
Code01102
Dimensions mm
Walnut wall plate
Ø 60
Ø 80
Code01103
Dimensions mm
Walnut round wall
Ø 80
Ø 100
Code01110
Dimensions mm
Oak wall plate
Ø 80
Ø 100
Code01111
Dimensions mm
Oak round wall plate
Ø 80
Ø 100
Code01112
Dimensions mm
Walnut wall plate
Ø 80
Ø 100
Code01113
Dimensions mm
Walnut round wall
Ø 100
Ø 120
Code01120
Dimensions mm
Oak wall plate
Ø 100
Ø 120
Code01121
Dimensions mm
Oak round wall plate
Ø 100
Ø 120
Code01122
Dimensions mm
Walnut wall plate
Ø 100
Ø 120
Code01123
Dimensions mm
Walnut round wall
l 126
l 140
Code01130
Dimensions mm
Oak wall plate for 503 box
Code01131
Dimensions mm
Oak round wall plate for 503 box
Code01132
Dimensions mm
Walnut wall plate for 503 box
h 60
l 126
l 140
h 60 h 60
l 126
l 140
l 126
l 140
Code01133
Dimensions mm
Walnut round wall plate for 503 box
h 60
01100 - 01101 - 01102 - 01103 combinable with items - codes:00100 - 00110 - 00120 - 00121 - 00200 - 00210 - 00220 - 00230 - 00240 - 00241 - 00242 - 01500
01110 - 01111 - 01112 - 01113 combinable with items - codes:01510 - 01530 - 01540 - 01600 - 01601
01120 - 01121 - 01122 - 01123 combinable with items - codes:01520 - 01610 - 01611
01130 - 01131 - 01132 - 01133 combinable with items - codes:00100 - 00110 - 00120 - 00121 - 00200 - 00210 - 00220 - 00230 - 00240 - 00241 - 00242
Code 00120
Dimensions mm Ø 60 - h 67
Porcelain impulse turn-switch 10A 230V
IP 20
Code00200
Dimensions mm Ø 60 - h 50
Porcelain universal italian standard select outlets 250V 10/16A
IP 20
Code00220
Dimensions mm Ø 60 - h 45
Porcelain telephone plug 6P/4C RJ 11
IP 20
Code00240
Dimensions mmØ 60 - h 50
Porcelain coaxial female connector TV Ø 9,5
IP 20
Code00242
Dimensions mm Ø 60 - h 55
Porcelain sat plug
IP 20
Code00110
Dimensions mm Ø 60 - h 67
1P - 10AX 2 way switch 230V
IP 20
Code00121
Dimensions mmØ 60 - h 53
Brass-porcelain push button for door bell 12V
IP 20
Code00210
Dimensions mm Ø 60 - h 51
Porcelain socket for UNEL plugs withcentral ground 250V 16A
IP 20
Code00230
Dimensions mm Ø 60 - h 45
Porcelain RJ45 plug unshielded C.5UTP T568A-B
IP 20
Code00241
Dimensions mm Ø 60 - h 50
Porcelain coaxial male connector TV Ø 9,5
IP 20
Accessories AccessoriesMedallions
Insulators
Code01200
Dimensions mm Ø 19 - h 24
Porcelain insulators with burnished screw and dowels
Code01210
Dimensions mm Ø 16 - h 23
Porcelain insulators
Code01300
Dimensions mm screw 3,5x50dowel Ø 5
Burnished screws withnylon dowels for insulators
Insulators Screws
h 25
Ø 33
Ø 25
h 24
Ø 30
Ø 20
h 23
Ø 24
Ø 16
Cable entry
Code 01400
Dimensions mm
Porcelain cable entry
Code01410
Dimensions mm
Porcelain cable entry
Code01420
Dimensions mm
Porcelain cable entry
Cable entry Cable entry
Accessories Junction boxes
h 51
Ø 60
Code01500
Dimensions mm
Porcelain junction box
h 57
Ø 80
Code 01530
Dimensions mm
Porcelain junction boxwith step relay 230V 8A
h 57
Ø 80
Code 01510
Dimensions mm
Porcelain junction box
h 59
Ø 100
Code01520
Dimensions mm
Porcelain junction box
h 57
Ø 80
Code01540
Dimensions mm
Porcelain junction boxwith step relay 12V 8A
h 35
Ø 80
h 35
Ø 80
h 35
Ø 100
Code01600
Dimensions mm
Porcelain medallion
Code01610
Dimensions mm
Porcelain medallion
h 35
Ø 100
Decorated porcelain medallion Decorated porcelain medallion
Code01601
Dimensions mm
Code01611
Dimensions mm
AccessoriesStep relay
Step relay
Code01700
Power12V - 8A
Code01701
Power230V - 8A
Step relay
Applicable standards: harmonised standards EN 60669 - 1 and 96 Low voltage CE Directive 73/23 - Italian law provision nr. 626 - 25 - 11- 96 Applicable standards: harmonised standards EN 60669 - 1 and 96 Low voltage CE Directive 73/23 - Italian law provision nr. 626 - 25 - 11- 96
Code Colour Section mt.38001 White 2x0,25 50
FIMKO
Code Colour Section mt.10001 White 2x0,5 100
10002 White 2x0,75 100
10003 White 2x1 100
10004 White 2x1,5 100
10005 White 2x2,5 100
10006 White 3x0,5 100
10007 White 3x0,75 100
10008 White 3x1 100
10009 White 3x1 50
10010 White 3x1,5 100
10011 White 3x1,5 50
10012 White 3x2,5 100
10013 White 3x2,5 50
10014 White 4x1,5 100
10015 White 4x1,5 50
Silk white covered cable CERTIFIED
Cables Cables
Silk ivory covered cable FIMKO CERTIFIED
FIMKOSilk gray covered cable CERTIFIED Silk brown covered cable FIMKO CERTIFIED
FIMKOSilk black covered cable CERTIFIED Silk gold covered cable FIMKO CERTIFIED
Code Colour Section mt.10201 Gray 2x0,5 100
10202 Gray 2x0,75 100
10203 Gray 2x1 100
10204 Gray 2x1,5 100
10205 Gray 2x2,5 100
10206 Gray 3x0,5 100
10207 Gray 3x0,75 100
10208 Gray 3x1 100
10209 Gray 3x1 50
10210 Gray 3x1,5 100
10211 Gray 3x1,5 50
10212 Gray 3x2,5 100
10213 Gray 3x2,5 50
10214 Gray 4x1,5 100
10215 Gray 4x1,5 50
Code Colour Section mt.10301 Brown 2x0,5 100
10302 Brown 2x0,75 100
10303 Brown 2x1 100
10304 Brown 2x1,5 100
10305 Brown 2x2,5 100
10306 Brown 3x0,5 100
10307 Brown 3x0,75 100
10308 Brown 3x1 100
10309 Brown 3x1 50
10310 Brown 3x1,5 100
10311 Brown 3x1,5 50
10312 Brown 3x2,5 100
10313 Brown 3x2,5 50
10314 Brown 4x1,5 100
10315 Brown 4x1,5 50
Code Colour Section mt.10401 Black 2x0,5 100
10402 Black 2x0,75 100
10403 Black 2x1 100
10404 Black 2x1,5 100
10405 Black 2x2,5 100
10406 Black 3x0,5 100
10407 Black 3x0,75 100
10408 Black 3x1 100
10409 Black 3x1 50
10410 Black 3x1,5 100
10411 Black 3x1,5 50
10412 Black 3x2,5 100
10413 Black 3x2,5 50
10414 Black 4x1,5 100
10415 Black 4x1,5 50
Code Colour Section mt.10501 Gold 2x0,5 100
10502 Gold 2x0,75 100
10503 Gold 2x1 100
10504 Gold 2x1,5 100
10505 Gold 2x2,5 100
10506 Gold 3x0,5 100
10507 Gold 3x0,75 100
10508 Gold 3x1 100
10509 Gold 3x1 50
10510 Gold 3x1,5 100
10511 Gold 3x1,5 50
10512 Gold 3x2,5 100
10513 Gold 3x2,5 50
10514 Gold 4x1,5 100
10515 Gold 4x1,5 50
FIMKOSilk bronze covered cable CERTIFIED Cotton white covered cable FIMKO CERTIFIED
Tv covered cable Telephone covered cable
Code Colour Section mt.10601 Bronze 2x0,5 100
10602 Bronze 2x0,75 100
10603 Bronze 2x1 100
10604 Bronze 2x1,5 100
10605 Bronze 2x2,5 100
10606 Bronze 3x0,5 100
10607 Bronze 3x0,75 100
10608 Bronze 3x1 100
10609 Bronze 3x1 50
10610 Bronze 3x1,5 100
10611 Bronze 3x1,5 50
10612 Bronze 3x2,5 100
10613 Bronze 3x2,5 50
10614 Bronze 4x1,5 100
10615 Bronze 4x1,5 50
Code Colour Section mt.18001 White 2x0,5 100
18002 White 2x0,75 100
18003 White 2x1 100
18004 White 2x1,5 100
18005 White 2x2,5 100
18006 White 3x0,5 100
18007 White 3x0,75 100
18008 White 3x1 100
18009 White 3x1 50
18010 White 3x1,5 100
18011 White 3x1,5 50
18012 White 3x2,5 100
18013 White 3x2,5 50
18014 White 4X1,5 100
18015 White 4x1,5 50
For digital tv For sat tv Code Colour Section mt.20001 White 90 db 50
20101 Ivory 90 db 50
20201 Gray 90 db 50
20301 Brown 90 db 50
20401 Black 90 db 50
20501 Gold 90 db 50
20601 Bronze 90 db 50
Code Colour Section mt.28001 White 90 db 50
Silk
Cotton
Cable waves don’t cause transmission loss.
Code Colour Section mt.30001 White 2x0,25 50
30101 Ivory 2x0,25 50
30201 Gray 2x0,25 50
30301 Brown 2x0,25 50
30401 Black 2x0,25 50
30501 Gold 2x0,25 50
30601 Bronze 2x0,25 50
Silk
Cotton
Silk CottonSilk Silk
Silk Silk
Silk Silk
Code Colour Section mt.10101 Ivory 2x0,5 100
10102 Ivory 2x0,75 100
10103 Ivory 2x1 100
10104 Ivory 2x1,5 100
10105 Ivory 2x2,5 100
10106 Ivory 3x0,5 100
10107 Ivory 3x0,75 100
10108 Ivory 3x1 100
10109 Ivory 3x1 50
10110 Ivory 3x1,5 100
10111 Ivory 3x1,5 50
10112 Ivory 3x2,5 100
10113 Ivory 3x2,5 50
10114 Ivory 4x1,5 100
10115 Ivory 4x1,5 50
Applicable standards: harmonised standards EN 60669 - 1 and 96 Low voltage CE Directive 73/23 - Italian law provision nr. 626 - 25 - 11- 96 Applicable standards: harmonised standards EN 60669 - 1 and 96 Low voltage CE Directive 73/23 - Italian law provision nr. 626 - 25 - 11- 96
GI GAMBARELLI S.r.l.
Via Borsellino 1/P 42019 - Arceto di Scandiano (RE) ItalyTel 0039 0522 980598 - Fax 0039 0522 989150
www.gigambarelli.com - [email protected]
GAMBARELLI