  • Irrigation System Controller

    Users Guide Setup Installation Programming Troubleshooting

    v Indoor and Outdoor 6-, 9-, and 12-station Models v

    English

    Espaol

    Franais

  • Getting to Know Your Rain Dial Controller . . . . . . . . . . . . . .23

    Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

    BatteryInstallationandArmchairProgramming . . . . . . . . . . 4-5

    Overview:ControlModuleInterface . . . . . . . . . . . . . . . . . . . . 6-7

    Overview:InternalControllerComponents . . . . . . . . . . . . . . 8-9

    Installation Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1015

    InstallingtheControllerCabinet . . . . . . . . . . . . . . . . . . . . . . . .10

    ConnectingtheValveControlWiring . . . . . . . . . . . . . . . . .1011

    ConnectingaRainSensor(optional) . . . . . . . . . . . . . . . . . . . .12

    ConnectingaRemoteControlUnit(optional) . . . . . . . . . . . . .13

    ConnectingtheEarthGroundDevice . . . . . . . . . . . . . . . . . . .14

    ConnectingthePowerSource . . . . . . . . . . . . . . . . . . . . . .1517

    IndoorModels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

    OutdoorModels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1617

    ControllerStationTestFeature . . . . . . . . . . . . . . . . . . . . . . . .17

    Getting the Most From Your Rain Dial Controller . . . . . . .1819

    SampleWateringPlan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

    What the Display Indicates . . . . . . . . . . . . . . . . . . . . . . . . . .2021

    Basic Programming Procedures . . . . . . . . . . . . . . . . . . . . .2225

    SettingtheCurrentTimeandDay . . . . . . . . . . . . . . . . . . . . . .22

    SettingtheValveRunTimeDuration . . . . . . . . . . . . . . . . . . .22

    SettingtheProgramCycleStartTime(s) . . . . . . . . . . . . . . . . .23

    SettingtheProgramWateringDaySchedule . . . . . . .2325

    ToSetaWeekdaySchedule: . . . . . . . . . . . . . . . . . . . . . .23

    ToSetaSkipDaySchedule: . . . . . . . . . . . . . . . . . . . . . . .24

    ToSetanOdd/EvenDateSchedule . . . . . . . . . . . . . .2425

    DayExclusionFeature . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

    ii

    F Table of Contents

  • Special Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2629

    RainDelay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

    WaterBudget . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2628

    ToApplyaBasicWaterBudget: . . . . . . . . . . . . . . . . . . . .27

    ToApplyaMonthlyWaterBudget: . . . . . . . . . . . . . . .2728

    Stack/Overlap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29

    StationDelay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29

    PumpControlDuringStationDelay . . . . . . . . . . . . . . . . . . . .30

    PumpControlOption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30

    Diagnostic Circuit Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . .31

    Fuse Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31

    Manual Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3233

    Semi-automaticProgramOperation . . . . . . . . . . . . . . . . . . . .32

    ManualStationOperation . . . . . . . . . . . . . . . . . . . . . . . . . . . .33

    Clear Program Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34

    Restore Rain Dial-R to Factory Default Settings . . . . . . . . . .35

    Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36

    Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37

    Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38

    FCC Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38

    1

  • F Getting to Know your Rain Dial Controller

    To take full advantage of your new Rain Dial-R controller, take a few moments to become familiar with its many features:

    Modular design Provideseasyaccesstovalveconnectionter-minalsandbatterystorage .Snap-outdesignenablesthecontrolmoduletobeeasilyremovedforArmchairProgramming .

    Remote control ready Built-inRJ-11jackfordirectconnectiontoIrritrolCMR-KITorKSR-KIThandheldremotecontrolsystems .

    Non-volatile memory Keepsalluser-definedwateringprogramsstoredinmemoryforseveralyearswithout power!

    Super Cap Providesabackuppowersourcetosustaincurrenttimeanddateduringapoweroutagelastingupto24hours .

    Battery back-upMaintainscurrenttimeanddateaduringpoweroutagelastinglongerthan24hours .AlsoenablesArmchairProgrammingofthecontrollerpriortoinstallation .

    Three independent watering ProgramsEnablesautomaticwateringProgramstobespecificallytailoredforvariousportionsofthelandscape;e .g .,lawns,shrubsandtrees .

    Three Start Timesper Program Enablesoperationofeachauto-maticProgramuptothreetimesperscheduledwateringday .

    Skip Days schedulingEnableswateringdaystobescheduledbyinterval,rangingfrom1(everyday)to31(onceevery31days) .

    Odd/Even date schedulingEnablesawateringdayscheduletobedefinedbyallodd-oreven-numberedcalendardays .

    Day Exclusion EnablesspecificweekdaystobeexcludedfromanOdd/EvendateorSkipDayswateringschedule .

    Program Stack/Overlap ProvidestheoptiontolimitoperationtooneProgram/stationatatime(Stack),orenableuptothreeProgramsorstationstooperateconcurrently .

    Station Test FeatureAconvenienttest-cyclefeatureoperateseachvalvestationinsequenceforaselectedruntimefrom110minutes .Perfect for new installations!

    Live programming Enablesprogrammingchangestobemadeatanytimeeven during watering!

    2

  • Fully automatic, semi-automatic and manual station operations .

    Manual AdvanceEnablesstationsequencetobeadvancedmanuallyduringoperation(manualorautomatic) .

    Off or Stop ImmediatelystopsandpreventsallwateringactivitywithoutdisturbingPrograms .

    Four places available to quickly remove start timesFourOFFpositionsareprovidedwithinthetimedisplaytoremoveunwantedstarttimes;significantlyreducingtheamountofscrollingrequired .

    Rain Delay Enablesautomaticwateringtobepostponedfrom1to9days;thenresumeautomaticallywateringasscheduled .

    Water BudgetEnablestheruntimeofallstationswithinaProgramtobescaledupto200%ordownto0%(Off) .Inaddition,aWaterBudgetvaluecanbeappliedtoindividualProgramsbyspecificmonthswhenseasonalwaterbudgetingispreferred .Thisisagreatfeatureforwatersmartapplications .

    MV/Pump control by station EnablesautomaticMasterValve/Pumpoperationtobecontrolledbyindividualstations .

    Station sequence delayProvidesanadjustabledelayperiodbetweenstationsduringtheoperatingsequencetoaccommodateslow-closingvalvesorarequiredwell-recoveryperiod .

    MV/Pump controlduring station delay EnablesMasterValve/Pumpoperationtobeactiveorinactiveduringastationdelayperiod .Rain Dial-R provides the choice!

    Built-in circuit protectionHelpsprotectthecontrollerselectroniccomponentsfromdamageduetopowerandnearbylightningsurges .

    Diagnostic Circuit Breaker Enablesthecontrollertodetectandbypassanystationwithashortcircuitorfaultysolenoid .DisplaysFUSandthebypassedstationnumberforeasytroubleshooting .

    Clear Program Memory EnablesProgrammemorytobeclearedandresetindependentlyofotherPrograms .

    Reset to Factory Program Defaults EnablesfactorydefaultProgramsettingstobeeasilyrestoredifrequired .

    3

  • F Getting Started

    Battery Installation & Armchair Programming

    Installinga9Vbattery(user-provided)servestwoimportantfunctions:first,itenablestheRainDial-Rtobefullyprogrammedpriortoinstallation,andsecond,itkeepsthecontrolmodulesynchronizedwithcurrenttimeanddateduringamainpowerinterruptionlastingmorethan24hours .Note: The battery is not capable of operating the sprinkler valves. Main AC power must be applied to the controller to enable operation.

    Thecontrolmoduleisdesignedtobeeasilyremovedforcompleteprogramminginamoreconvenientsetting,suchasyourfavoritearmchair .Toremovethecontrolmodule,simplyunplugtheribboncableconnectorfromtheprintedcircuitboard,thencarefullyremovethemodulefromitssnap-inhinges .TheRainDial-Rfeaturesnon-volatilememory,whichkeepstheprogramminginformationintact,evenifthebatterydiesorisdisconnected .

    Installing the Battery1 . Openthecont