Kompact user and maintenance manual Version : 3 1 SWIMMING POOL MONITORING SYSTEM User and maintenance manual Read carefully and keep for future reference. Please study the manual closely, before bringing the system into service (Version 3) 1 - The content of this booklet may be modified without prior notice. 2 - Printing restrictions mean that the displays shown in this booklet may vary from those actually appearing on the product. 3 - The content of this booklet may not be reproduced in any way without the manufacturer's permission.

Upload: others

Post on 17-May-2020

44 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: User and maintenance manual - Amazon S3€¦ · Kompact user and maintenance manual Version : 3 4 1 DESCRIPTION You have just purchased your Klereo Kompact system. It regulates the

Kompact user and maintenance manual Version : 3

1

SWIMMING POOL MONITORING SYSTEM

User and maintenance manual

Read carefully and keep for future reference. Please study the manual closely, before bringing the system into service (Version 3)

1 - The content of this booklet may be modified without prior notice. 2 - Printing restrictions mean that the displays shown in this booklet may vary from those actually appearing on the product. 3 - The content of this booklet may not be reproduced in any way without the manufacturer's permission.

Page 2: User and maintenance manual - Amazon S3€¦ · Kompact user and maintenance manual Version : 3 4 1 DESCRIPTION You have just purchased your Klereo Kompact system. It regulates the

Kompact user and maintenance manual Version : 3

2

Table of contents 1 DESCRIPTION ..................................................................................................................................................... 4

2 KLEREO INTERFACE ............................................................................................................................................ 5

3 HOME SCREEN ................................................................................................................................................... 6

4 MAIN MENU ...................................................................................................................................................... 7

5 SENSORS VALUES .............................................................................................................................................. 7

6 PROGRAMMING FILTERING, LIGHTING AND AUXILIARIES ................................................................................. 8

6.1 AVAILABLE PROGRAMMING MODES ............................................................................................................................... 8 6.2 MANUAL MODE ........................................................................................................................................................ 9 6.3 REGULATED MODE (FILTERING) .................................................................................................................................... 9 6.4 TIME SLOTS MODE ..................................................................................................................................................... 9 6.5 BACKWASH / WASTE MODE ...................................................................................................................................... 10 6.6 TIMER MODE ......................................................................................................................................................... 10 6.7 SYNCHRONIZED MODE .............................................................................................................................................. 10

7 WATER TREATMENT ........................................................................................................................................ 11

7.1 PH CORRECTING AGENT ............................................................................................................................................ 11 7.1.1 Regulated mode ........................................................................................................................................ 11 7.1.2 Stop mode ................................................................................................................................................. 11 7.1.3 Fixed volume mode ................................................................................................................................... 11

7.2 DISINFECTANT......................................................................................................................................................... 11 7.2.1 Regulated mode ........................................................................................................................................ 12 7.2.2 Stop mode ................................................................................................................................................. 13 7.2.3 Boost treatment mode .............................................................................................................................. 13 7.2.4 Fixed volume mode: in case of active Oxygen or liquid Chlrorine ............................................................. 14 7.2.5 Fixed time mode: in case of Chlorine or Bromine tablets .......................................................................... 14 7.2.6 Synchronized filtering mode: in case of Bromine or Chlorine tablets and Salt Chlorinator ....................... 14 7.2.7 ORP regulated mode: in case of Salt Chlorinator ...................................................................................... 14

7.3 ADVANCED PARAMETERS .......................................................................................................................................... 14 7.3.1 Reset daily treatment ................................................................................................................................ 14 7.3.2 Balanced pH .............................................................................................................................................. 14 7.3.3 Abort salt treatment – resume salt treatment (with Klereo Salt Chlorinator) .......................................... 15

8 OUTPUTS ASSIGNEMENT ................................................................................................................................. 15

9 HEATING .......................................................................................................................................................... 15

10 MAINTENANCE ................................................................................................................................................ 16

10.1 PH PROBE CALIBRATION ....................................................................................................................................... 16 10.2 ORP PROBE CHECKING ......................................................................................................................................... 16 10.3 CONSUMPTIONS ................................................................................................................................................. 16 10.4 RESET CONSUMPTIONS. ....................................................................................................................................... 16

11 CONTROL MODES ............................................................................................................................................ 16

12 SYSTEM STATUS .............................................................................................................................................. 17

12.1 INPUTS STATUS ................................................................................................................................................... 17 12.2 SYSTEM STATUS .................................................................................................................................................. 17 12.3 POOL INFORMATION ............................................................................................................................................ 17 12.4 CLEAR MESSAGES ................................................................................................................................................ 17

Page 3: User and maintenance manual - Amazon S3€¦ · Kompact user and maintenance manual Version : 3 4 1 DESCRIPTION You have just purchased your Klereo Kompact system. It regulates the

Kompact user and maintenance manual Version : 3

3

13 PARAMETERS .................................................................................................................................................. 17

13.1 INTERFACE ......................................................................................................................................................... 17 13.2 HEATING SET-UP ................................................................................................................................................. 18 13.3 PRIORITIES AND SECURITIES SET-UP ........................................................................................................................ 18

14 SOFTWARE ...................................................................................................................................................... 18

15 MAINTENANCE PROCEDURES .......................................................................................................................... 18

15.1 CHANGING WATER TREATMENT PRODUCT TANK ........................................................................................................ 18 15.2 WINTERING ....................................................................................................................................................... 19

15.2.1 Metering pumps ................................................................................................................................... 19 15.2.2 pH and ORP probes storage ................................................................................................................. 19

15.3 FIRST USE, RE-OPENING OF THE POOL ...................................................................................................................... 20

16 PROBLEMS SOLVING ........................................................................................................................................ 21

17 SECURITY INSTRUCTIONS ..................................................................................................................................... 23

18 BATTERIES AND ELECTRONIC EQUIPMENTS DISPOSAL .................................................................................... 23

Page 4: User and maintenance manual - Amazon S3€¦ · Kompact user and maintenance manual Version : 3 4 1 DESCRIPTION You have just purchased your Klereo Kompact system. It regulates the

Kompact user and maintenance manual Version : 3

4

1 DESCRIPTION

You have just purchased your Klereo Kompact system. It regulates the filtering cycles depending on the water temperature and the pool characteristics (volume in m3, power and flow rate of the filter pump). It regulates also the pH and disinfectant

There are 4 Kompact models according to the selected disinfectant: liquid Chlorine / Salt Chlorinator / Bromine or Chlorine tablets / active Oxygen. Klereo Kompact allows piloting 2 more outputs: pool lighting, cleaning robot, spa, counter current system, garden lighting, fountain, and so on. The default set-up of Kompact is as follows:

• Filtering regulation • pH regulation • Disinfectant régulation • Lighting • An auxiliary function (Aux A): cleaning robot, spa, counter current system, garden lighting,

fountain, and so on.

This set-up is adjustable. According to your wish, you can modify the following functions: • Lighting can be replaced by a second auxiliary function (Aux B) or a dosing pump to add

flocculant. • Auxiliary A can be replaced by the heating function.

To modify functions, refer to §8: outputs assignment.

Page 5: User and maintenance manual - Amazon S3€¦ · Kompact user and maintenance manual Version : 3 4 1 DESCRIPTION You have just purchased your Klereo Kompact system. It regulates the

Kompact user and maintenance manual Version : 3

5

Browse

LCD screen

Confirm

Back or cancel

Screen selection key

Shortcut or screen selection key

2 KLEREO INTERFACE

Figure 1. Ecran et touches de navigations Klereo Kompact

The ON or fault indicator light is: - Steady green when the Kompact control box unit is power supplied and filtering, pH and

disinfectant regulation is possible. - Flashing red when the Kompact control box unit is power supplied and there is a fault.

Refer to the menu « message » to know the fault.

The filtering indicator light: - Steady green when the filtering is permanently on (manual ON) - Flashing green when the filtering is on for a cycle (regulated / time slots or external

command) - Flashing red when filtering is not possible because of a security or a fault. - Off when filtering is stopped.

Browse:

Key Definition Screen selection key: the functions for these keys are listed in the display at the

bottom of the LCD screen. The functions vary according to the menu shown..

Browse key: for browsing and sometimes for changing values displayed.

Confirm key: for accessing a sub-menu or confirming an action

Back or Cancel key: for cancelling an action or returning to the previous menu

OK

C

- - -

ON or fault indicator light

Filtering indicator light

Page 6: User and maintenance manual - Amazon S3€¦ · Kompact user and maintenance manual Version : 3 4 1 DESCRIPTION You have just purchased your Klereo Kompact system. It regulates the

Kompact user and maintenance manual Version : 3

6

3 HOME SCREEN

Figure 2. Home screen

Browse:

Key Definition Klereo menu access

Shortcut key for direct access to the programming menu for the chosen function

Browse key: For selecting lighting, filtering, heating (if installed), auxiliaries 1 and 2 functions.

For accessing a sub-menu or confirming an action

No function on this screen

The values of the pH, air and water temperature sensors flash when filtering is stopped. Their display is steady when filtering is running for at least 10 min. Wait for 30 to 90 min with ORP.

1. Date and time. Alternately with “messages” if any.

2. pH and water temperature values 3. Display area for status functions*. 4. Function symbols* 5. Programmed modes and status of

functions* 6. Shortcut to selected function*

*equipment connected to Klereo Kompact control box (lighting, Filtering, heating if installed auxiliary)

K l e r e o

2

3

6

1 4 5

OK

C

-

- -

Page 7: User and maintenance manual - Amazon S3€¦ · Kompact user and maintenance manual Version : 3 4 1 DESCRIPTION You have just purchased your Klereo Kompact system. It regulates the

Kompact user and maintenance manual Version : 3

7

4 MAIN MENU

Press screen selection key to access main menu, use the browse key to select the required sub-menu and press OK to enter. The main menu is used to access the pool functions and other sub-menus:

- Messages : to read the pool alerts. - Sensor value : list of sensors value - Filtering, Water treatment, Lighting, Heating, Auxi liary : to parameter the different pool equipments. - Maintenance : to indicate the different elements consumptions (water treatment products and pool equipments) and to check and calibrate the probes. - Control Modes : to select between “comfort” and “eco” mode - System Status : shows the operational status of the Klereo system - Parameters : to access system parameters - Software : to know the installed software version and do the updating.

5 SENSORS VALUES

To check the values measured for the sensors, go to the menu:

Klereo Sensors

Values are transmitted by the Kompact control box unit at regular intervals (or every time you press the snapshot button inside the Kompact control box unit).

The pH and ORP values shown are only used for regulation after a filtration period of 10 min (pH) and 30 to 90 min (ORP).

Klereo Messages

Sensors Filtering

Water treatment

Lighting

Auxiliary A

Maintenance Control modes

System status

Parameters

Software

IMPORTANT

In case of message, the symbol « MESSAGES » flashes on the top right end of the display alternately with the date and time. A sub-menu « messages » is then added in the main menu

listing.

Page 8: User and maintenance manual - Amazon S3€¦ · Kompact user and maintenance manual Version : 3 4 1 DESCRIPTION You have just purchased your Klereo Kompact system. It regulates the

Kompact user and maintenance manual Version : 3

8

6 PROGRAMMING FILTERING, LIGHTING AND AUXILIARIES

You can access these functions by going through the main menu or using the shortcut selection key on the home screen.

6.1 Available programming modes

Function Programming mode

Operat ing mode

Filtering

Regulated Filtering regulated according to water temperature

Time slots Operation programmed in time slots

Manual Always ON or OFF

Backwash / Waste

Force filtering to perform backwash or waste while stopping disinfection and disabling temporarily water flow security.

Lighting

Force Filt. Filtering is on when lighting is on

Timer Automatically turned off at the end of the setup time.

Time slots Operation programmed in time slots

Manual Always ON or OFF

Auxiliary

Force Filt. Filtering is on when auxiliary is on

Timer Automatically turned off at the end of the setup time.

Time slots Operation programmed in time slots

Manual Always ON or OFF

Filtering Sync Auxiliary is on when filtering is on

Force filtering option is available for lighting and auxiliaries functions. It enables filtering to be started up at the same time as the operating periods defined for lighting and/or auxiliary systems outside the filtering periods calculated or planned for treatment. Essential when using a booster pump for a cleaning robot for instance. If another auxiliary (B, 1 or 2) is set up, a corresponding menu will appear with the same available programming modes as for auxiliary A.

Figure 3. Programming screen

Page 9: User and maintenance manual - Amazon S3€¦ · Kompact user and maintenance manual Version : 3 4 1 DESCRIPTION You have just purchased your Klereo Kompact system. It regulates the

Kompact user and maintenance manual Version : 3

9

Browse:

Key Definit ion On in manual mode (On/Color for lighting) and On/Off in timer mode

For confirming the change of programming mode and performing the following actions: Stop in manual mode, Modify in timer or time slots mode and Info in regulated mode

Browse key to select the programming mode.

For accessing a sub-menu or confirming an action

Cancel or return to previous menu

6.2 Manual Mode

The manual mode is for setting the function ON or OFF. If filtering is on OFF manual mode, Klereo system will not regulate water treatment and heating. A message «filt. manual off» will appear on the display.

6.3 Regulated mode (filtering)

With this mode, filtering is regulated according to the water temperature. By pressing the screen selection key below « info » you can visualize the automatically calculated filtering time slot for the day. Before getting to this information, filtering must have been on for at least 10 min.

6.4 Time slots mode

With this mode you can decide the filtering time slots that you wish to program. For filtering, lighting and the auxiliaries you can define time slots with a 15 min minimum duration time. For filtering, time slots must be at minimum 2 hours in a row. Indeed, to guarantee a good treatment regulation (pH and disinfectant), filtering programming must include 2 consecutive hours minimum time slots.

Figure 4. Time slots mode adjustment screen

Browse:

Key Definition

Change of status: On / Off Change of time slot. Time slot is adjustable with 15min.time step*

confirm

Cancel or return to previous menu

*Programming time is indicated above the programming slots bar.

OK

C

-

- -

OK

C

Page 10: User and maintenance manual - Amazon S3€¦ · Kompact user and maintenance manual Version : 3 4 1 DESCRIPTION You have just purchased your Klereo Kompact system. It regulates the

Kompact user and maintenance manual Version : 3

10

6.5 Backwash / Waste mode

This mode enables to force filtering while conducting a filter backwash or waste operation and, at the same time, stopping disinfection and disabling temporarily water flow security. You can then conduct your operation with complete peace of mind. Backwash and waste duration is adjustable between 2 min and 4 hours (same procedure as to adjust timer mode: see below). Once set up, when starting this mode, it is displayed on the home screen. Indeed, close to the filtering icon, a message alternately indicates the operation mode: “backwash”, “on”. Once the operation completed, it is necessary to reset the previous mode by going to the “filtering” menu through the home screen or through the menu.

6.6 Timer Mode

With this mode, lighting and auxiliaries will automatically turn off at the end of the programmed time.

Figure 5. Timer mode adjustment screen

Browse:

Key Definition

For changing duration time

Confirm

Cancel or return to previous menu

6.7 Synchronized mode

With this mode, lighting or an auxiliary will work at the same time as filtering does. The auxiliary output will be activated 10s after filtering starts.

OK

C

Page 11: User and maintenance manual - Amazon S3€¦ · Kompact user and maintenance manual Version : 3 4 1 DESCRIPTION You have just purchased your Klereo Kompact system. It regulates the

Kompact user and maintenance manual Version : 3

11

7 WATER TREATMENT

This menu deals with water treatment secured by maintaining the right pH value (thanks to the pH correcting agent) and a sufficient disinfectant ratio by adding Chlorine (Sodium hypochlorite), bromine, acrive Oxygen (Hydrogen peroxide) or by using a Salt Chlorinator.

In any case, we strongly advise to measure once a month, using a tester or photometer, the disinfectant ratio and the pH value in order to adjust the treatment regulation if necessary.

7.1 pH correcting agent

With this menu you set up the pH operational mode:

Klereo Water treatment pH cor. agent Regulated Stop Fixed volume

Programming modes are identical for both pH correcting agent (pH minus or pH plus) .

7.1.1 Regulated mode

With this mode the Klereo system injects the pH correcting agent according to the measured pH value and the programmed pH target value.

In case of pH minus, if the measured pH value is above the programmed pH target value, Klereo will inject pH correcting agent to reach the target value. In case of pH plus, if the measured pH value is below the programmed pH target value, Klereo will inject pH correcting agent.

7.1.2 Stop mode

This mode can be temporarily used during wintering or when adding specific products to adjustt some chemical parameters such as TAS, TH, and so on (please ask your Klereo specialist).

7.1.3 Fixed volume mode

This mode can be used when the pH probe is defective while waiting for its replacement so that the pool disinfection is still running correctly,. To determine the right volume to inject, contact your Klereo specialist who will advise you taking into consideration the pool volume and water temperature.

The fixed volume mode can be programmed daily, weekly, monthly or as a unique injection in order to suit all needs..

7.2 Disinfectant

With this menu you set up the disinfectant operational mode. The possible modes are not the same according to the selected disinfectant.

There are 4 disinfectants: Chlorine, Bromine, active Oxygen and Salt Chlorinator.

In case of liquid Chlorine or Active Oxygen treatme nt , you can choose among:

Klereo Water treatment Disinfectant Regulated Stop Boost treat Fixed volume

Page 12: User and maintenance manual - Amazon S3€¦ · Kompact user and maintenance manual Version : 3 4 1 DESCRIPTION You have just purchased your Klereo Kompact system. It regulates the

Kompact user and maintenance manual Version : 3

12

In case of Chlorine or Bromine tablets treatment , you can choose among:

Klereo Water treatment Disinfectant Regulated Filt. Synch. Stop Boost treat Fixed time

In case of Klereo Salt Chlorinator treatment , you can choose among:

Klereo Water treatment Disinfectant Regulated ORP regul. Filt. Synch. Stop Boost treat.

In case of other Salt Chlorinator treatment (not co mpatible with K-link protocol), operational modes are more limited:

Klereo Water treatment Disinfectant Filt. Synch. Stop Boost treat.

7.2.1 Regulated mode

The regulated mode is advised by Klereo as the system will optimize the swimming pool water treatment according to its characteristics and its needs.

a. In case of liquid Chlorine or Bromine/Chlorine t ablets

We advise to measure the pool disinfectant ratio (Chlorine or Bromine) and to modify the ORP target control value if you wish to increase or decrease the disinfectant concentration.

With this treatment mode, klereo will inject the disinfectant according to the values measured by the ORP probe and the programmed ORP target value while taking into consideration the pool characteristics. If the value measured by the ORP probe is below the target value, Klereo will inject disinfectant and will stop injection when the target value is reached.

b. In case of active oxygen or Salt Chlorinator

We advise to measure the pool disinfectant ratio (Chlorine in case of Salt Chlorinator) and to modify the ORP target control value if you wish to increase or decrease the disinfectant concentration.

The disinfection is regulated according to the pool volume and the water temperature. This mode is suitable for the majority of pools but in some cases, you may found out that the treatment is too high or too low.

You can change the treatment ratio parameter by selecting « modify » in the menu and by pressing the “OK” validation key. The temperature regulated mode is default selected in “typical” mode.

Then by using the arrows on the browse key, you can decide to decrease the injections (in case of active Oxygen) or the working time (in case of Salt Chlorinator) by -20, -40, -60% or to increase them by +20, +40, +60%. This can be useful when there are many people in the pool.

Page 13: User and maintenance manual - Amazon S3€¦ · Kompact user and maintenance manual Version : 3 4 1 DESCRIPTION You have just purchased your Klereo Kompact system. It regulates the

Kompact user and maintenance manual Version : 3

13

Figure 6. Modification of the regulated mode

c. ORP security

In case of a Salt Chlorinator, you can parameter an ORP security value in order to stop the Chlorinator when this maximum value is reached. This security works with any type of Salt Chlorinator: Klereo models and other brands.

The default value is 800mV.

It can be modified by going to menu:

“Klereo” / ”Water treatment” / “Advanced parameters” / “Salt chl. ORP/Chl secur.”

7.2.2 Stop mode

This mode enables to stop disinfection and works with any type of disinfectant. It can be temporarily used during wintering or when adding specific products to adjust some chemical parameters such as TAS, TH, and so on (please ask your Klereo specialist).

7.2.3 Boost treatment mode

This mode enables to make a boost treatment: to be launched at the begining of the season and/or when the disinfectant ratio is very low and/or whenever needed (the water is becoming green). Boost treatment lasts 24h, the way to proceed varies according to the type of disinfectant.

a. In case of liquid Chlorine or Bromine/Chlorine t ablets

Boost treatment is done by increasing the ORP target value by 100mV and maintaining this value for 24h. This is automatically done when launching the boost treatment. Once the boost treatment is completed, treatment regulation comes back to its predefined operational mode.

IMPORTANT

Indoor pool and/or pool cover ratio

When a Klereo Salt Chlorinator is installed, Chlori ne production will be reduced by 80% in the following 2 cases:

- When the pool cover is closed and

- When the pool is set up as an indoor pool.

This 80% ratio is adjustable in the menu: - Klereo / water treatment / advanced parameters / pool cover ratio - Klereo / water treatment / advanced parameters / indoor pool ratio

Page 14: User and maintenance manual - Amazon S3€¦ · Kompact user and maintenance manual Version : 3 4 1 DESCRIPTION You have just purchased your Klereo Kompact system. It regulates the

Kompact user and maintenance manual Version : 3

14

b. In case of active Oxygen and Klereo Salt Chlorin ator

Boost treatment is done by increasing the predefined treatment level: for active Oxygen, the quantity of volume of injected product will be multiplied by 4.5 and for Salt Chlorinator treatment duration will be multiplied by 4.5 in order to last longer.

c. In case of another Salt Chlorinator

Boost treatment with another Salt Chlorinator will force filtering for 24h so that disinfection lasts the same duration.

7.2.4 Fixed volume mode: in case of active Oxygen or liquid Chlorine

This mode enables to adjust the quantity of product injected daily. To determine the right value, contact your Klereo specialist who will advise you according to pool volume, type of disinfectant and water temperature.

The fixed volume mode can be programmed daily, weekly, monthly or as a unique injection in order to suit all needs.

7.2.5 Fixed time mode: in case of Chlorine or Bromine tablets

This mode enables to adjust the treatment duration, i.e. when the solenoid valve remains open to let the water going through the brominator or chlorinator in order to load the disinfectant. This duration varies according to pool volume, type of disinfectant and water temperature. You can contact your Klereo specialist who will advise you.

7.2.6 Synchronized filtering mode: in case of Bromine or Chlorine tablets and Salt Chlorinator

This mode enables a synchronized disinfection together with filtering duration.

7.2.7 ORP regulated mode: in case of Salt Chlorinator

This mode is to be used in specific set-up and requires the use of the ORP probe (optional).

7.3 Advanced parameters

Some functions are not explained in this manual but are detailed in the Kompact installation manual as they refer to settings to parameter during installation. You will find below the sub-menus presentation that will be useful when using Klereo Kompact during the season or re-starting the pool.

7.3.1 Reset daily treatment

This menu enables to reset the treatment made during the day when it has reached its quantity daily limit. You can then start again disinfection without launching a boost treatment.

7.3.2 Balanced pH

Klereo Water treatment Advanced parameters Balanced pH

This menu enables to calculate the balanced pH of the water based on the TAS (alkalinity) and TH (hardness) values. The balanced pH is the « reference » pH respecting the water balance, ensuring it does not cause scale build-up or become aggressive. Whenever possible we advise to fix a target pH value close to the balanced pH value, taking also into consideration the type of disinfectant selected to as to set a target value to guarantee the best treatment efficiency. It may be necessary to correct the TAS (easier to modify) or the TH in the pool to get closer to the balanced pH.

Page 15: User and maintenance manual - Amazon S3€¦ · Kompact user and maintenance manual Version : 3 4 1 DESCRIPTION You have just purchased your Klereo Kompact system. It regulates the

Kompact user and maintenance manual Version : 3

15

Figure 7. Balanced pH calculation

7.3.3 Abort salt treatment – resume salt treatment (with Klereo Salt Chlorinator)

These 2 menus appear when a Klereo salt treatment is set up: • Abort salt treatment: this menu enables to abort treatment in progress until midnight • Resume salt treatment: this menu enables to resume all daily treatment cycles.

8 OUTPUTS ASSIGNEMENT Klereo Kompact outputs are default set up when delivered. If you wish to modify this set-up refer to §5.12: outputs assignment in the Kompact installation manual. 9 HEATING

The menu « Heating » is displayed once a heating system is installed. You can access this menu by going through either the main menu or the shortcut selection key on the home screen:

Klereo Heating

Heating can be programmed in off mode or self-regulated mode. In self-regulated mode, enter the desired temperature target value and the heating system will stay on until the water reaches the temperature target value. Heating regulation is not possible when filtering is off.

Figure 8. Heating temperature target value setting screen

Press the screen selection key below TAS and TH to enter measured values into the pool

If there is no heating system, set the heating on ‘OFF’ position.

Page 16: User and maintenance manual - Amazon S3€¦ · Kompact user and maintenance manual Version : 3 4 1 DESCRIPTION You have just purchased your Klereo Kompact system. It regulates the

Kompact user and maintenance manual Version : 3

16

Browse:

Key Defini tion Typical value: matches the default value set in the factory

Auto/Off: to stop heating or set heating in self-regulated mode

Change of target value

Confirm

Cancel or return to previous menu

10 MAINTENANCE

10.1 pH probe calibration

Please refer to §5.5.1: calibration of pH probe in the Kompact installation manual.

10.2 ORP probe checking

Please refer to §5.5.2: checking ORP probe in the Kompact installation manual.

10.3 Consumptions

This menu displays the pH and disinfectant consumptions as well as filtering, heating, lighting and auxiliaries outputs operating times according to set up equipments. Press any selection key to access to the list of parameters.

10.4 Reset consumptions.

This menu enables you to reset the different consumptions.

11 CONTROL MODES

Klereo Control modes With this menu, you can choose between the comfort and the eco mode.

• Comfort mode will always favour water quality. Indeed, when filtering time is coming to an end, filtering will continue if one of the 2 parameters (pH and disinfectant) has not reached its target value. Filtering will stop when the target value is reached. This control mode is ideal during the season to guarantee the best water quality.

-

- -

OK

C

IMPORTANT

Ph, liquid Chlorine and active Oxygen consumptions are calculated according to the metering pumps outputs operating time on the Kompact control box unit. Make sure that the pumps remain connected and that the treatment tanks are not completely empty. Filtering, heating, lighting and auxiliaries operating time match the corresponding outputs operating time on the Kompact control box unit .

Page 17: User and maintenance manual - Amazon S3€¦ · Kompact user and maintenance manual Version : 3 4 1 DESCRIPTION You have just purchased your Klereo Kompact system. It regulates the

Kompact user and maintenance manual Version : 3

17

• Eco mode to favour energy savings. When filtering time is coming to an end,

filtering will stop even though one of the 2 parameters (pH and disinfectant) has not reached its target value. Regulation will resume the following day after the new filtering cycle has been initiated. This control mode can be used at the beginning and at the end of the season.

12 SYSTEM STATUS

Klereo System status This menu enables to get information about inputs / outputs status.

12.1 Inputs status

This menu enables to list the selected inputs (pool cover, water flow, water treatment product tank, 220V inputs…) and their status: OK, 0 or 220V, tank empty, …

12.2 System status

This menu sums up system status. Press any key button to scroll down or up the list.

Designation Description Control mode Comfort or Eco mode pH correcting agent

Indicates the selected pH correcting agent: pH Minus or pH Plus

Disinfectant Indicates the selected disinfectant product Filtering Indicates the programmed filtering mode pH Programmed pH target value ORP Programmes ORP value Freeze control Deactivated function for the Kompact range Heating Programmed heating temperature target value

12.3 Pool information

Sums up the pool and its equipments information.

12.4 Clear messages

This menu enables to clear posted messages, once read.

13 PARAMETERS

Some functions are not detailed into this manual but are available for consultation inside the installation manual as they have to be set up during installation: sensors set-up, equipments set-up, inputs set-up and installation tests. We present and explain below the sub-menus that might be useful to you during the season or when starting the season every year.

13.1 Interface

The « Interface » menu is used to set date and time, select language and adjust brightness and contrast on the screen. The date and time are set in the factory. This information should be modified when time periods are changed (summer-winter time).

Klereo Parameters Interface Adjust the date

Adjust the time

Language Display settings Contrast

Page 18: User and maintenance manual - Amazon S3€¦ · Kompact user and maintenance manual Version : 3 4 1 DESCRIPTION You have just purchased your Klereo Kompact system. It regulates the

Kompact user and maintenance manual Version : 3

18

Browse:

Key Definition Typical value in the backlight and contrast menu: matches the default value set in

the factory

change of values selecting active field

For accessing a sub-menu or confirming an action

Cancel or return to previous menu

13.2 Heating set-up

Please refer to §5.13: heating in the Kompact installation manual in order to set up the heating type and operational mode as well as the heating temperature target value.

13.3 Priorities and securities set-up

Please refer to §5.15: priorities and securities set-up in the Kompact installation manual if you want to know their use and to set up those that you wish to select.

14 SOFTWARE

This menu indicates your Klereo software version and enables to decide if you need an updating or not.

15 MAINTENANCE PROCEDURES

Check regularly the pool water level as well as water chemical parameters using a chemical analysis test kit. Use regularly the cleaning robot or brush the pool walls. Before conducting any operation on Klereo Kompact control box unit, turn off the power supply.

15.1 Changing water treatment product tank

When you see an empty tank message, it means that you must replace the corresponding water treatment product tank. Proceed as follows, using adapted protective wear (gloves, glasses, closed shoes…) in order to avoid chemicals projections on the skin:

� When there is no drawing up cane with water level detector:

Remove the pipe together with the strainer from the empty tank and put them inside the new tank.

� In case of installed drawing up cane with water level detector:

- Unscrew the tank plug and remove gently the cane with the transparent flexible pipe (PVC) and the electrical connexion wire.

- You can use the plug from the previous tank if identical OR

- Drill a 32mm diameter hole onto the new tank plug - Slide the cane into the plug - Adjust the conical black collar position so that it fitting the tank neck and that the drawing up

cane level detector bottom is touching the tank bottom. When installing the drawing up cane into the new tank, make sure that it remains in vertical position.

- -

OK

C

Page 19: User and maintenance manual - Amazon S3€¦ · Kompact user and maintenance manual Version : 3 4 1 DESCRIPTION You have just purchased your Klereo Kompact system. It regulates the

Kompact user and maintenance manual Version : 3

19

IMPORTANT

The pH and ORP probe heads must never remain dry but should be stored in tap water. Do not use distilled water.

15.2 Wintering

15.2.1 Metering pumps

The santoprene tube inside the metering pump is the part to be protected during wintering. Draw clear water through to rinse the pipe and avoid premature deterioration.

Activate the metering pump using the adequate menu on the display (refer to §5.6, regulations test in the Kompact installation manual), so that the roller is positioned as shown on the picture below. It will allow minimum deterioration from the santoprene tube.

Figure 9. Metering pump

15.2.2 pH and ORP probes storage

pH and ORP probes useful life is between 1 and 3 years in normal operational condition. It can be substantially reduced according to storage conditions, when measured values fluctuate significantly or when water temperature exceeds 60°C. When wintering the pool, we advise to store pH and ORP probes as follows: - remove the probe from the probe holder - rinse the probe with tap water - fill the protective cap with tap water - put back the probe head into the

protective cap - or let the probes soak into a glass of

tap water checking regularly that the heads are always into water.

Roller

IMPORTANT

The santoprene tubes inside the metering pump are to be changed once a year. Refer to the metering pump manual.

Roller axis

Page 20: User and maintenance manual - Amazon S3€¦ · Kompact user and maintenance manual Version : 3 4 1 DESCRIPTION You have just purchased your Klereo Kompact system. It regulates the

Kompact user and maintenance manual Version : 3

20

When putting back the probes into the probe holders, make sure to respect the positioning of the different parts as shown on the picture below:

Figure 10. Re-positioning the probe holders

15.3 First use, re-opening the pool

At the start of every season, we advise to proceed as follows: - Measure the water chemical parameters (TAS, TH, pH, Chlorine and stabilizer) and modify pH and ORP target values if necessary. - Check the ph and ORP probes head

- Calibrate the pH probe: refer to §5.5.1 in the Kompact installation manual

- Check the ORP probe: refer to §5.5.2 in the Kompact installation manual - Check the metering pumps santoprene pipe (to be changed every year) - Check that the water treatment drawing pipes and injection pipes connected to the metering pumps are free from impurities - Check the pH and ORP target values.

1: probe-holder upper part 2: rubber washer 3: metal washer 4: flat rubber washer 5: probe-holder body

1 2

3

4

5

IMPORTANT

If the technical room is outside and the water or t he air temperature goes below zero, you must winter the pH and ORP probes as well as the pressure sensor in order to avoid any damage because of the frost. Use the plugs supplied with the kit and install them instead of the probes and the sens or. Store them in a temperate room. In that case disable the water treatment regulation s and the pressure sensor.

Page 21: User and maintenance manual - Amazon S3€¦ · Kompact user and maintenance manual Version : 3 4 1 DESCRIPTION You have just purchased your Klereo Kompact system. It regulates the

Manuel d’utilisation Kompact Version : 1.1

21

16 PROBLEMS SOLVING

The following table shows the list of possible messages, their definition and how to resolve. For some messages, we have not detailed all possibilities but indicated a cross-reference number to additional tables at the end. Example: «Sensor broken», the message will also tell you which sensor is broken. For instance, « pH sensor broken » meaning that the pH probe is defective: you should check the probe wiring connexion or calibration. If it still does not work after checking, change the probe. Proceed the same way when the message is « ORP sensor broken », « water temp. sensor broken » , …

MESSAGES DEFINITION RESOLUTION

Sensor broken +"sensor designation (3) » The sensor is defective

Check the probe wiring connexion / calibration. If negative, change the probe.

Invert pH/ORP pH and ORP probes are inverted Invert the probes

Minimum +" sensor designation (3)

The value measured by the probe is below the minimum set level.

Check the treatment product injections or Check the set values and modify them if necessary

Maximum +" sensor designation (3)

The value measured by the probe is above the maximum set level

Check the treatment product injections or Check the set values and modify them if necessary

Not transmitted +" sensor designation (3)

The probe has not transmitted for over 1 hour

Check the probe wiring connexion / calibration. If negative, change the probe.

Water flow problem The water flow is incorrect

Check the flow switch wiring connexion Check the flow switch operation in the menu: Klereo/ Parameters/ Tests-Install. / Inputs status

Insuf. filt. T.Slots Minimum of 2 hours is necessary ! Set up again the filtering time slot

pH>8 Ineff.disinfect Disinfectant is inefficient as long as pH is that high

Check the water treatment regulations and the injector valve condition

Low filter pump flow Filter pump undersized compared to the pool volume Change the filter pump

Regul. stopped pH or disinfectant regulation has been stopped manually

Set up again pH and disinfectant treatments in regulated mode

Filt Manu. Off Filtering is in manual mode « OFF » Select with OK « regulated» or « time slots » or « manual» mode

Boost treatment Filtering is forced for 24H Leave filtering « ON » Day limit injection + " Treatment probe designation (2)"

Daily maximum quantity has been injected

Check pool volume Check treatment injections and probes operation

RF Link Chlorinator The Salt Chlorinator is matched but does not communicate with the Kompact

Check the communication cable

Page 22: User and maintenance manual - Amazon S3€¦ · Kompact user and maintenance manual Version : 3 4 1 DESCRIPTION You have just purchased your Klereo Kompact system. It regulates the

Manuel d’utilisation Kompact Version : 1.1

22

Bromine problem The ORP value does not increase ….

Check if there are tablets in the brominator and the solenoid valve operation in the menu: Klereo / Parameters / Tests-Install. / Regulation tests

Chlorinator cell Short circuit problem or …..

Check message on Salt Chlor. display (ex lack of salt, gaz, overheating and so on) and possible short circuits

Heat pump link fault The heat pump is matched but does not communicate with the Kompact Check the communication cable

Sensor set-up problem Selected sensors do not match the selected water treatment

Check the selected treatment mode

Salt Chlor. security. The Salt Chlorinator cannot produce ….

Heat the water or increase ORP maximum value

Link problem + "Equipment name (1)"

The Klereo treatment (1) is not matched with the Kompact

For matching go to menu: Klereo / Parameters / Set-up / Radio match

Very low ORP ORP lower than 50mv or over 2200 mV

Check the probe wiring connexion / calibration. If negative, change the probe.

Equipment designation (1) Sensor designation (3) Ouput designation (4)

Klereo heat pump ORP Auxil. A or aux. designation (5)

KLEREO 2 Salt Chl. Water Auxil. B or aux. designation (5)

pH Heating

Treatment probe designation (2) Pool cover Disinfect

pH Treat . tank Lighting

ORP pH tank Filter

Flocculant

pH minus

Auxiliaries designation (5)

Booster Lights. W. blade

Spa Fountain Sprinkle

Blower C-Current U.V.

Mot. valve

Page 23: User and maintenance manual - Amazon S3€¦ · Kompact user and maintenance manual Version : 3 4 1 DESCRIPTION You have just purchased your Klereo Kompact system. It regulates the

Manuel d’utilisation Kompact Version : 1.1

23

17 SECURITY INSTRUCTIONS

The Klereo Kompact electrical installation must be made by the approriate sate of the art professional respecting the local electrical standards. Before conducting any operation on Klereo Kompact control box unit, turn off the power supply. The water treatment products must not be placed directly on the floor. Install them on a waterproof rack. By using a drip tub to put each tank in, you avoid mixing chemical products in case of leaks. When handling chemical products, use protective wear: gloves and glasses. It is also important to work in a sufficiently ventilated room to avoid fumes built-up. Avoid any contact between liquid Chlorine, Bromine and pH- or pH+. Mixing the water treatment products is extremely dangerous. Klereo disclaim all responsibility.

18 BATTERIES AND ELECTRONIC EQUIPMENTS DISPOSAL

IMPORTANT:

This equipment carries the 'waste separation' symbol for electric and electronic equipments recycling purposes. It means that this equipment must be taken care by a waste collecting system according to the 2002/96/CE EEC guideline in order to be either recycled or dismantled to eliminate any environmental damage. For more information, please contact your local governing administration. Electronic products not going through a waste separation process are potentially dangerous to the environment and human health because of potential harmful substances.