USE AND INSTALLATION
WARNING: This equipment requires regular maintenance to ensure the treated water’s potability; use it according to the user guide.
3
USE AND INSTALLATION | ZERO
DIMENSIONS
4
ZERO | USE AND INSTALLATION
Pipe8X6 mm
2 m 6.56 ft
9300733
Pipe ¼”
1 m3.28 ft
9300522
T-fitting F/F/M
1 piece
9400334
Straight M adapter3/8”
1 piece
9300258
M/Fmini ball valve M/F
1 piece
9400300
Stem elbow ¼”
1 piece
9300728
Straight female connector
2 pieces
9300734
Gooseneck faucet kit
1 piece
XO0001BTW
Drain clampkit
1 piece
1100137
Straight female adapter
1 piece
9300651
Stem elbow 8 mm
2 pieces
9300735
O-ring 3021
1 piece
1100223
COMPONENT LIST
5
USE AND INSTALLATION | ZERO
INSTALLATION SCHEME
Correct positioning of the device
drain
drain
mix
in
in
out
out
6
ZERO | USE AND INSTALLATION
INSTALLATION
Before the installation, remove the yellow IN and OUT plugs as well as the DRAIN plug, which is to be inserted again in case the device is relocated
1
2
Drain plug extraction
1. Keep the collet pressed down
2. Take out the plug
7
USE AND INSTALLATION | ZERO
Drain clamp kit
1 piece
Pipe ¼”
just enough
Stem elbow ¼”
1 piece
DHI
Gasket
Drain clamp kit assembly
DRAIN CIRCUIT INSTALLATION
8
ZERO | USE AND INSTALLATION
1/3
2/3
Drill ø 6 mm / 15/64”
DRAIN CIRCUIT INSTALLATION
9
USE AND INSTALLATION | ZERO
3/3
D
H
I
DRAIN CIRCUIT INSTALLATION
drain
10
ZERO | USE AND INSTALLATION
T-fitting F/F/M
1 piece
Mini ball valve M/F
1 piece
Straight female connector
1 piece
Pipe8X6 mm
just enough
Stem elbow 8 mm
2 pieces
B CA F G E
INLET CIRCUIT INSTALLATION
Straight M adapter 3/8”
1 piece
11
USE AND INSTALLATION | ZERO
INLET CIRCUIT INSTALLATION
Before installation, ensure to turn off the cold water valve
CLOSE
PLEASE NOTE! Before installation, cover with Teflon Tape (not included).
12
ZERO | USE AND INSTALLATION
1/4
2/4
A
B C
Cold water pipe
INLET CIRCUIT INSTALLATION
PLEASE NOTE! Before installation, cover with Teflon Tape (not included).
PLEASE NOTE! Before installation, cover with Teflon Tape (not included).
13
USE AND INSTALLATION | ZERO
3/4
4/4
G
E
F
INLET CIRCUIT INSTALLATION
in
14
ZERO | USE AND INSTALLATION
Fixing nut
1 piece
Toothed washer
1 piece
Plastic washer
1 piece
Rubber gasket
1 piece
Spacer with o-ring
1+1 pieces
54321
Faucet
1 piece
For the faucet working instructions, see page 18.
L
FAUCET INSTALLATION
15
USE AND INSTALLATION | ZERO
1/2
2/2
L
1
54
32
FAUCET INSTALLATION
Drill ø 12 mm / 15/32”
16
ZERO | USE AND INSTALLATION
O-ring 3021
1 piece
Straight female adapter
1 piece
Pipe8X6 mm
justenough
Stem elbow 8 mm
1 piece
Straight female connector
1 piece
K J G E F
OUTLET CIRCUIT INSTALLATION
17
USE AND INSTALLATION | ZERO
out
K J G E
F
OUTLET CIRCUIT INSTALLATION
1/2
2/2
18
ZERO | USE AND INSTALLATION
red light 7 sec
blue light 7 sec
yellow light 7 sec
light off 7 sec
red blue yellow light 3 sec
ATTENTION: DON’T MOVE THE TAP KNOB BEFORE THE SEQUENCE IS COMPLETED
If the reset is correct, the blue LED flashes while you suply water. If the reset is not correct, the red LED flashes.
If the tap is closed and you don’t supply water for more than 8 hours, when you open the tap, the yellow LED flashes for 3 seconds. Wait for the LED to turn blue before drinking or using water.
When the circuit counter reaches the count of 2,800 minutes, the blue LED stops flashing, and the red LED starts flashing to indicate the reserve, until you get to 3,000 minutes.
When 3,000 minutes have passed, you will need to change the filter. The red LED stays on or doesn’t flash, indicating that the cartridge is exhausted, even if the tap is not delivering water. The red LED also flashes after a calendar year has passed from the circuit start, indicating that you have to change the filter. In any case, reset the circuit. If 3,000 minutes or a calendar year haven’t passed and you remove and reinsert the battery, the count reset will not happen, as the circuit will normally store the minutes it has delivered within a 3,000 minute or year cycle.
1
1 2 3 4 5
TAP CIRCUIT FUNCTIONSSTART/RESET THE CIRCUIT
Close the tap, insert the battery into the circuit, and insert it into the tap within 30 seconds, verify that the 1 LEDs flash with this sequence: the red for 7 seconds, the blue for 7 seconds and the yellow for 7 seconds. The LEDs remain off for 7 seconds and if the circuit detects a successful reset, the 3 LEDs will flash simultaneously for about 3 seconds. If the circuit didn’t detect the reset, the red LED flashes and stays on constantly, so remove and insert the battery again.
LED light installation sequence
2
3
4
5
19
USE AND INSTALLATION | ZERO
USE
IF YOU HEAR A NOISE DURING FIRST USE, PLEASE DO THE FOLLOWING PROCEDURE:
• put ZERO in the vertical position in order to let the air flow out of the system
• do at least 3 cycles of filling and emptying to condition the system
• put ZERO in the horizontal position
N.B. the noise should disappear after some cycles and/or after some hours
20
ZERO | USE AND INSTALLATION
CARTRIDGE REPLACEMENT
Before replacing the cartridges, turn the cold water valve off and turn on the faucet until all of the water runs out.
CLOSE OPEN
21
USE AND INSTALLATION | ZERO
TO REMOVE TO INSERT
Before you insert the cartridge, wet the O-ring
CARTRIDGE REPLACEMENT
1
2
Turn clockwise
Turn counter-clockwise
Pull Push
22
ZERO | USE AND INSTALLATION
Remove the cap
CARTRIDGE REPLACEMENT
Small o.d.ø 11.50 mmø 0.45”
Large o.d.ø 12.75 mm
ø 0.5”
Replacement cartridges kit
Post-filterPre-filter
23
USE AND INSTALLATION | ZERO
UTILITY
Technical specifications
Time flow rate 24 l/h (@ 4 bar)
Working pressure min./Max. 1.5 bar/6 bar | 21.7 PSI/87 PSI*
Temperature min./Max. 5/35°C | 41/95°F
Test conditions
Inlet water temperature rejection
15°C | 59°F
Rejection >90
Recovery (typically at a pressure of 36 psi)
40%
Inlet pressureCapacity supplied
in 1 minute Refill reserve
bar/PSI L/min min.
2.5/36 2.4 15
3/43 2.7 12
4/58 3.2 8
REFILL TIME SUPPLY TIME
Inlet pressure (Bar)Inlet pressure (Bar)
CHEMICAL PHYSIC ANALYSISR&C LAB s.r.l. | Altavilla Vicentina
Samples taken in the factory located on via delle Pezze 35 35013 Cittadella PD, Italy
Min
.
60
45
30
15
0
140
105
70
35
00 01.5 1.53 34.5 4.56 6
Sec
.
Parameter (with by-pass off) IN OUT
Conductivity at 77°f µS/cm 289 14.7
Hydrogen ion concentration pH 8.15 7.54
Chloride mg/l 3.1 0.223
Sulfates mg/l 19.3 0.572
Zinc µg/l Zn 11.8 n.r.
Calcium mg/l Ca 32.4 1.48
Magnesium mg/l Mg 11.5 0.45
Potassium mg/l K 0.7 0.176
Sodium mg/l Na 2.07 0.52
Total phosphorus µg/l P2O5 29.8 n.r.
Hexavalent chromium µg/l Cr 0.94 n.r.
Nitrates mg/l 3.5 2.9
7097034Aquaporin-ZERO-USER MANUAL | Revised: April 2, 2020
Aquaporin A/S Nymøllevej 78 2800 Kongens Lyngby Denmark
VAT No.: DK28315694 Tel: +45 82 30 30 82 [email protected]
aquaporin.com