usb control from pc pc running analyzer sw ex350 ... - ellisys · c . uut . ex350 . generator...
TRANSCRIPT
![Page 1: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB](https://reader030.vdocuments.mx/reader030/viewer/2022012823/5bebb24909d3f26e208bff1b/html5/thumbnails/1.jpg)
Device C C
USB Control from PC
Custom Cables
EX350 Analyzer
A B
A
host C
B
C
Gnd CC
Vconn SBU1 & 2
SSTX2/RX2 Shield
Vbus Gnd
D+/D- SSTX1/RX1
Shield
Analyzer
1
PC Running Analyzer SW
![Page 2: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB](https://reader030.vdocuments.mx/reader030/viewer/2022012823/5bebb24909d3f26e208bff1b/html5/thumbnails/2.jpg)
UUT C
EX350 Generator (EXAMINER)
A B
C
PC Running Examiner
or Generator SW and Analyzer SW
USB Control from PC
Custom Cable
A
EX350 Analyzer
A B
A
B
B
CC
GND
STD-A to STD-B (for Vbus)
2
Examiner or Generator with Analyzer Setup for USB Host-capable UUT
Vconn
![Page 3: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB](https://reader030.vdocuments.mx/reader030/viewer/2022012823/5bebb24909d3f26e208bff1b/html5/thumbnails/3.jpg)
UUT A
EX350 Generator (EXAMINER)
A B
A
PC Running Examiner
or Generator SW and Analyzer SW
USB Control from PC
A
EX350 Analyzer
A B
A
B
B
STD-A to STD-B
3
Examiner or Generator with Analyzer Setup for USB Host-capable UUT
With Std-A connector
STD-A to STD-B
![Page 4: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB](https://reader030.vdocuments.mx/reader030/viewer/2022012823/5bebb24909d3f26e208bff1b/html5/thumbnails/4.jpg)
UUT C
EX350 Generator (EXAMINER)
A B
C
PC Running Examiner
or Generator SW and Analyzer SW
USB Control from PC
Custom Cable
A
EX350 Analyzer
A B
A
B
B
CC
GND
STD-A to STD-B (for Vbus)
4
Examiner or Generator with Analyzer Setup for USB Device-capable UUT
Vconn
![Page 5: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB](https://reader030.vdocuments.mx/reader030/viewer/2022012823/5bebb24909d3f26e208bff1b/html5/thumbnails/5.jpg)
UUT B
EX350 Generator (EXAMINER)
A B
B
PC Running Examiner
or Generator SW and Analyzer SW
USB Control from PC
STD-A to STD-B
A
EX350 Analyzer
A B
A
B
B
STD-A to STD-B (for Vbus)
5
Examiner or Generator with Analyzer Setup for USB Device-capable UUT
With Std-B Connector
![Page 6: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB](https://reader030.vdocuments.mx/reader030/viewer/2022012823/5bebb24909d3f26e208bff1b/html5/thumbnails/6.jpg)
Device C C
Type-C to Type-C Adapter
EX350 Analyzer
A B
Device C C C C GND GND GND
VBUS CC1 CC2
Ellisys Type-C Breakout Rev A
Dn Dp
SBU2
SBU1
C C
CC GND
6
USB Control from PC
PC Running Analyzer SW
Alternate Approach for Analyzer
Info: orientation must be determined manually
![Page 7: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB](https://reader030.vdocuments.mx/reader030/viewer/2022012823/5bebb24909d3f26e208bff1b/html5/thumbnails/7.jpg)
Device C
EX350 Generator (EXAMINER)
A B
C
Custom Cable
A
USB Control from PC
7
Examiner or Generator (without Analyzer) for USB Host-capable UUT
PC Running Examiner or Generator SW
(No Analyzer)
![Page 8: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB](https://reader030.vdocuments.mx/reader030/viewer/2022012823/5bebb24909d3f26e208bff1b/html5/thumbnails/8.jpg)
Device C
EX350 Generator (EXAMINER)
A B
C
Custom Cable
A
USB Control from PC
8
Examiner or Generator (without Analyzer) for USB Device-capable UUT
PC Running Examiner or Generator SW
(No Analyzer)
![Page 9: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB](https://reader030.vdocuments.mx/reader030/viewer/2022012823/5bebb24909d3f26e208bff1b/html5/thumbnails/9.jpg)
Device
EX350 Analyzer
A B
A
Host C
B
C GND GND GND
VBUS CC1 CC2
Ellisys Type-C Breakout Rev A
Dn Dp
SBU2
SBU1
C C C
Type-C to Type-C Adapter
Captive
9
Captive Cable Approach
USB Control from PC
PC Running Analyzer SW
C
Info: orientation must be determined manually
![Page 10: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB](https://reader030.vdocuments.mx/reader030/viewer/2022012823/5bebb24909d3f26e208bff1b/html5/thumbnails/10.jpg)
DP Sink (dongle)
EX350 Analyzer
A B
A
DP source
B
GND SBU1 SBU2
VBUS CC1 CC2
Ellisys Type-C Extender Rev A
Dn Dp C C
Type-C to Type-C Adapter
Captive
10
Analzying DP Alt mode without blocking video signal
USB Control from PC
PC Running Analyzer SW
C
Info: orientation must be determined manually
C-plug
C-receptacle
C
C-plug
C-receptacle CC
GND
Vconn
Note: A and B USB ports are not used on EX350, since they do not pass DP data
Note: in Analyzer mode, these 2 headers are electrically connected either one may be used for CC, VCONN, and GND connection
![Page 11: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB](https://reader030.vdocuments.mx/reader030/viewer/2022012823/5bebb24909d3f26e208bff1b/html5/thumbnails/11.jpg)
EX350 Generator (EXAMINER)
A B
PC Running Examiner
or Generator SW and Analyzer SW
USB Control from PC
Custom Cable
A
EX350 Analyzer
A B
A
B
B
CC GND
STD-A to STD-B (for Vbus, opt.)
11
Generator with E-Marked Cable
VConn
GND GND GND
VBUS CC1 CC2
Ellisys Type-C Breakout Rev A
Dn Dp
SBU2
SBU1
C C C C C
E-Marked Cable
Type-C to Type-C Adapter
Info: orientation must be determined manually
![Page 12: USB Control from PC PC Running Analyzer SW EX350 ... - Ellisys · C . UUT . EX350 . Generator (EXAMINER) B . A . C . PC . Running Examiner . or Generator SW and Analyzer SW . USB](https://reader030.vdocuments.mx/reader030/viewer/2022012823/5bebb24909d3f26e208bff1b/html5/thumbnails/12.jpg)
Type-C to Type-C Cable
EX350 Analyzer
A B
Device C C C
CC
GND
12
USB Control from PC
PC Running Analyzer SW
Analyzer Passive Tapping to Board UUT
Device
CC GND
C