Power Line 400 safe and reliable
B E N N I N G W o r l d C l a s s P o w e r S y s t e m s
General
More and more data centres and production facilities make
higher demands on UPS systems. Non-linear or unbalanced
loads have to be controlled as much as instantanuous load
changes, overloads and high inrush currents. Today UPS are
considered an integral part of any data centre and can mean
a high investment.Therefore compromising on the reliability
and efficiency of the UPS does not make sense.
Economic advantages of the technology
The PL 400 uses IGBT power simiconductors and the latest
design in rectifiers and inverter technology. This means the
PL 400 operates without any mains feedback and does not
draw any reactive power from the mains (see figure).
Therefore, no complex or costly harmonic filters are required.
The advantages of the PL 400:
• Increased reliability with lower component count
• No additional costs for filters
• No resonance effects due to wrongly balancedfilters
• No interference problems with diesel generators
• No harmonic problems at the input, unlike 6 or 12-pulse
UPS systems
• Generators can be sized smaller because no reserve is
required to cope with harmonic oscillation
Reliability without any compromises
The Power Line 400 is a UPS complies with the highest stan-
dards for safety and reliability for power supplies without
compromising it´s efficiency. The combination of the 16 bitmicro-controller and the latest power electronic control and
monitoring design allow the user to access all the UPS´s
functions. The Power Line 400 is a true on-line UPS with dou-
ble voltage conversion and a constant voltage and frequency
output. In the event of mains failure the power is supplied
uninterrupted by the battery without a break in the output of
the UPS. Even at 100% unbalanced loads, a very high voltage
constant is maintained so as not to endanger the protected
load. Most EDP loads generate high peak currents, even with
three times the nominal current, the quality of the output is
not effected or the need to go to by-pass mode. In essence it
provides perfect UPS protection.
Power Line 400 with sinusoidal input current insured THD < 5%.
UPS with 6-puls
rectifier
UPS with 12-puls
rectifier
PL 400 with IGBT
rectifier
I n p u t c u r r e n t
time
8/20/2019 Ups Power Line 400-07-02
http://slidepdf.com/reader/full/ups-power-line-400-07-02 3/6
3B E N N I N G W o r l d C l a s s P o w e r S y s t e m s
Power Line 400 powerfull and compact
Space saving and compact
Space and volume are critical factors for the total cost
calculation of a UPS. With this in mind the PL 400 is designed
in order to minimise it´s footprint. The design of the high per-
formance heat sink allows us to concentrate the whole
power electronics on one sub-assembly.The system is also
designed to allow access to all vital components through the
front.
Parallel operation and redundency
The PL 400 can be connected in parallel and requires no
external control (no master/slave operation). The system has
the option of up to eight systems in parallel to all the UPS to
grow with your requirements.The cabinets can be easily
configuered and repuire no special cables for parallel
operation.
Easy operation
All available intormation on the status of the PL 400 can be
accessed via the control panel.The control panel can be
tilted to allow the user a more comfortable reading position.
• Current condition through circuit diagram with LED
operating status
• LCD with 80 characters given plain text information
• Password protection against unintentional operation
• User guidance with clear and easy instructions
• Event monitor for the last 1200 events
• Complete documentation of date, time and events in
plain text
• User configuerable
• Language selection
• Selection of 100 different battery variations• Functional setting of parameters and remote control
Guarantee of highest battery availability
The battery is an essential part of the UPS´s function. With the
PL 400 the status and condition of the battery is constantly
monitored. Temperature controlled charging maximises thelife of the battery.
• Low voltage protection switches off the battery before an
under voltage state occurs.
• Cyclic battery testing monitors the battery condition
• Battery monitoring provides the user with information on
the batteries capacity and the battery back-up with the
current load.
• Total discharge testing is available to test the battery capa-
city against predetermined levels.
UPS system Power Line 400
PL 400
operating unit
front view
side view (tilt out)
inside view
8/20/2019 Ups Power Line 400-07-02
http://slidepdf.com/reader/full/ups-power-line-400-07-02 4/6
4
Power Line 400 onlinediagnosis and monitoring
B E N N I N G W o r l d C l a s s P o w e r S y s t e m s
PL 400 Cabinet
inside view with and without safety guard
A complete system for the remote diagnostics and
monitoring
The PL 400 allows remote access to the system for error
diagnosis and fault finding. Recall of system messages is
available from the event memory.All operating and system
messages such as change in status and main interruptions
are maintained with a date and time of the event. Recall of
real time data of voltage, frequency, current and power is
also available. The monitoring system can also be configured
to the users specific requirements, this includes updating of
the PL 400 software via modem and if required the system
can auto-dial a specified service provider in the event ot
system errors.
SNMP – integration of the Power Line 400 into the
network management
The "Simple Network Management Protocol" (SNMP) is a
standardized and worldwide used network protocol which
allows easy monitoring of all network components. Therefore,
the PL 400 can be very easily integrated into existing
network management systems such as e.g. HP-Openview,
IBM-Netview, Novell NMS and other SNMP-compatible
systems.
UPSMON – central operating data acquisition and
monitoring
UPSMON is a complete information software for the monito-
ring of either individual or multiple power systems eitherthrough a serial interface, modem or network. It allows real-
time monitoring of all system events in a graphical format.
This information can be copied over to databases and spre-
adsheets for further analysis.
Simple remote diagnosis and
monitoring via modem
UPSMAN – automatic power shut-down and
monitoring software
Systematic shut-down of individual work stations or entire
networks. UPSMAN is available for all common operatingsystems, e.g. Windows 9.X / NT / 2000, OS/2, Novell
Netware, UNIX, Linux.
8/20/2019 Ups Power Line 400-07-02
http://slidepdf.com/reader/full/ups-power-line-400-07-02 5/6
B E N N I N G W o r l d C l a s s P o w e r S y s t e m s
Power Line 40060, 80, 120, 160, 200 kVA
Technical data of Power Line 400
Type PL 400/60 PL 400/80 PL 400/120 PL 400/160 PL 400/200
Nominal power kVA 60 80 120 160 200
kW 48 64 96 128 160
Input
Nominal voltage V 400 ±15 %, 50 Hz ± 5 %Harmonic distortion factor ≤ 5 %
Power factor ≥ 0,97
Output
Nominal voltage V 400
Voltage tolerance < 1 % static
< 1 % at 100 % out-of balance load
< 5 % at 100 % load bounce
Settling time ms ≤ 10
Nominal frequency Hz 50 ± 0,1%
Voltage harmonic < 1 % at linear load
distortion factor < 5 % at nonlinear load acc. to EN 50091-1-1
Crest factor ≥ 3
Overload 150 % for 10 sec., 125 % for 10 min. at 3-phase load
220 % for 10 sec., 180 % for 10 min. at single-phase load
By-pass
Overload 1000 % for 150 ms., 150 % for 10 min.
General data
Overall efficiency % 91 92 92 92 93
Battery
Cell number 192 192 192 2 x 198 2 x 198
Power kW 49,3 65,6 98,5 131,5 164,1
EMC EN50091-2 standard class A
Permissible °C 0 - 40
ambient temperature
Relative air humidity 5 % - 95 % not condensing
Installation height < 1000 m above sea level without performance reduction
System of protection IP 21
Colour RAL 7035 structured
Dimensions H x W x E mm 1400 x 750 x 880 1800 x 1000 x 800
Weight kg 900 900 1100 850 850
High reliability combined with high efficiency and ease of operation
• Capable of supporting out of balance loads
• Ability to operate in parallel
• High efficiency
• No feedback on the mains
Features
• Internal manual by-pass
• Key pad with mimetic circuit diagram and LC display
• Memory for the last 1200 events
• I/O board (12-digit input, 6-digit output, 6 relays)
• Interface board (RS 232, RS 485, PCMCIA)
Options
• Parallel operation of up to 8 systems
• I/O board (12-digit input, 6-digit output, 6 relays)
• Interface board (RS 232, RS 485, PCMCIA)
• External service by-pass
• Battery cabinet
Economic advantages of IGBT technology • Sinusoidal input current
-> no harmonic oscillation on the mains side
• No reactive power consumption
-> saves energy and provides higher efficiency
• No filters
-> increased reliability
• No expensive filter balancing
• No resonance effects due to badly or wrongly balanced
filters
Management interfaces:
• PL-CONNECT modem remote diagnosis• PL-NET SNMP adapter and shut-down software
• UPS-MON central remote control via PC
• RCP remote control panel
• ZLT mod bus
Additional technical information:
8/20/2019 Ups Power Line 400-07-02
http://slidepdf.com/reader/full/ups-power-line-400-07-02 6/6
B E N N I N G W o r l d C l a s s P o w e r S y s t e m s
I S O
1 4 0 0 1
www.benning.de
BENNING worldwide
AustriaBenning GmbH Elektrotechnik und Elektronik
Eduard-Klinger-Str. 9 A-3423 St. Andrä-WördernTel. 02242/3 2416-0Fax 02242/3 2423E-Mail: [email protected]
BelgiumBenning BelgiumPower ElectronicsZ. 2 Essenestraat 16B-1740 TernatTel. 02/ 5828784 (85)Fax 02/ 5828769E-Mail: [email protected]
Czech RepublicBenning CR s.r.o.Zahradní ul. 894CZ-293 06 Kosmonosy(Mladá Boleslav)Tel. 0326/ 721003Fax 0326/722533E-Mail: [email protected]
FranceBenning Conversion d’énergie43, avenue Winston ChurchillB.P. 418F-27404 Louviers CedexTél. 02/32252394
Fax 02/32250864E-Mail: [email protected]
GermanyTheo BenningElektrotechnik und Elektronik GmbH & Co.KGMünsterstr. 135-137D-46397 BocholtTel. 028 71/93-0Fax 02871/93297E-Mail: [email protected]
Great-BritainBenning Power Electronics (UK) Ltd.Oakley HouseHogwood LaneFinchampsteadGB-BerkshireRG 40 4QWTel. 0118 9731506Fax 0118 9731508E-Mail: [email protected]
HungaryBenning Kft.Power ElectronicsRákóczi út 262H-2541 LábatlanTel. 033/ 507600Fax 033/ 507601
E-Mail: [email protected]
IndiaBenning SMC Power Systems (P) Ltd.
10, Electronic City, Sec.-18,IND-Gurgaon -122015, HaryanaTel. 0124/6 455203 – 09Fax 0124/6 455212, 6346465E-Mail: [email protected]
IrelandTheo Benning GmbHNorth Industrial EstateWhitemill NorthIRE-Wexford / Rep. IrelandTel. 053/ 41795Fax 053/41841E-Mail: [email protected]
IsraelLaor Energy ltd.P.O.B. 570IL-Nazereth Elite 17105Tel. 03/6 872551Fax 03/6 871110E-Mail: [email protected]
ItalyBenning Conversione di Energia S.r.l.
Via E. Mattei, 7I-40138 BolognaTel. 051/ 531955Fax 051/530923
E-Mail: [email protected]
NetherlandsBenning NLPower ElectronicsPeppelkade 42NL-3992 AK HoutenTel. 030/ 6346010Fax 030/6346020E-Mail: [email protected]
PolandBenning Power Electronics Sp.z.o.o.Korczunkowa 30PL-05-503 GloskówTel. 022/ 7578453/7 573668-70Fax 0 22/ 7578452E-Mail: [email protected]
P. R. of ChinaBenning V. GmbHShanghai Repr. Office1233 Si Ping Rd., Rm. 006PRC-200 092 ShanghaiTel. 021 55570609Fax 02165041878
E-Mail: [email protected]
Russian FederationOOO Benning Power Electronics
Schtscholkovskoje Chaussee, 5RF-105122 MoscowTel. 095 /9676850Fax 095/9676851E-Mail: [email protected]
South East AsiaBenning Power Electronics Pte Ltd1, Kaki Bukit View# 05-03/04 TechviewSGP-Singapore 415941Tel. (65) 6844 3133Fax (65) 68443279E-Mail: [email protected]
SwedenEldaco ABBox 990,Hovslagarev. 3BS-19129 SollentunaTel. 08/ 6239500Fax 08/ 969772E-Mail:[email protected]
SwitzerlandBenning Power Electronics GmbHIndustriestrasse 6CH-8305 DietlikonTel. 01/8057575Fax 01/8057580
E-Mail:[email protected]
SpainBenning Conversión de Energía S.A.C/Pico de Santa Catalina 2Pol. Ind. Los LinaresE-28970 Humanes, MadridTel. 91/6048110Fax 91/6048402E-Mail: [email protected]
UkraineBenningul. Solomenskaja, 3BUA-252110 KiewTel. 044/ 24610 25Fax 044/ 2489236E-Mail: [email protected]
U.S.A.Lucas-BenningPower Electronics, Inc.11120 Grader StreetUSA-Dallas,TX 75238Tel. 214 5531444Fax 214 5531355
E-Mail: [email protected]
7 8 4 1 9 5
. 0 0
0 3
/ 2 0 0 2
p a u s D e s i g n & M e d i e n
, B o c h o l t
S u b j e c t t o a l t e r a t i o
n s
.
P r i n t e d o n c h l o r i n e
f r e e p a p e r .