updated cv 2016

22
JEFFREY D. AUSTRIA Balikbayan road, Bendana compound Tanay, Rizal. Philippines Mobile +639176834503 Email: legendmammals1968@ gmail .com Skype: jepgiejael Position Desired: NDT INSPECTOR Level II RT, RTFI, PT, MT, UT FLAW PERSONAL DATA: Age : 34 yrs. old Date of Birth : March 31, 1981 Place of Birth : Malaya, Pililla, Rizal Gender : Male Civil Status : Married Height : 5’3" Weight : 115 lbs. Religion : Christian Seaman book : C0037786 Passport no. : EB6152164 Language/Dialect : English/Tagalog SSS no. : 33-6974292-5 Citizenship : Filipino TIN : 305-035-847-000 Philhealth : 01-050228132-7 Pag-ibig tracking no. : 914175546438 EDUCATIONAL BACKGROUND: College : Computer (Programming) AMA Computer Learning Center

Upload: jeffrey-austria

Post on 18-Jan-2017

14 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: UPDATED CV 2016

JEFFREY D. AUSTRIA Balikbayan road, Bendana compound

Tanay, Rizal. PhilippinesMobile +639176834503Email: legendmammals1968@ gmail .com Skype: jepgiejaelPosition Desired: NDT INSPECTOR Level II

RT, RTFI, PT, MT, UT FLAW

PERSONAL DATA:

Age : 34 yrs. oldDate of Birth : March 31, 1981Place of Birth : Malaya, Pililla, RizalGender : MaleCivil Status : MarriedHeight : 5’3"Weight : 115 lbs.Religion : ChristianSeaman book : C0037786Passport no. : EB6152164Language/Dialect : English/TagalogSSS no. : 33-6974292-5Citizenship : FilipinoTIN : 305-035-847-000Philhealth : 01-050228132-7Pag-ibig tracking no. : 914175546438

EDUCATIONAL BACKGROUND:

College : Computer (Programming)AMA Computer Learning CenterPlaza Aldea, Tanay, RizalJune1998 – March 2000

Secondary : Malaya National High SchoolMalaya, Pililla, Rizal1994 – 1998

Elementary : San Ildefonso CollegeTanay,Rizal

Page 2: UPDATED CV 2016

1988-1999EMPLOYMENT HISTORY:

Company : ASIA GULF and PACIFICPosition : NDT CoordinatorIndustry : Oil and Gas Duration : Dec. 17 – Up to presentLocation : Cabinda, Angola (offshore)

PRIMARY FUNCTION:

ASIA GULF and PACIFIC (AGnP) as a subcontractor of DAEWOO SHIPBUILDING AND MARINE ENGINEERING LTD. (DSME). and CHEVRON.

CABINA GULF OIL COMPANY LTD.

MAFUMEIRA SUL PROJECT, CENTRAL PROCESSING COMPLEX at Cabina Angola (OFFSHORE)

SCOPE OF WORK

PREPARING RT ENDORSEMENT for everyday Radiography Activities including daily RT PLAN.

Preparing ISO Drawing, PNID for welded joints to survey by the surveyor

Updating and Encode Welding Monitoring for RADIOGRAPHIC welded joints that is already accepted and repair welds, including Complete Welding Production given by every Welder Forman.

Collecting all RT tracing paper to the RT Supervisor

Prepare ISO drawing to the every tracing paper that is given and distribute in all Welding Foreman and Welding Supervisor for their repairing activities.

Survey all requested joints and do Film Evaluation and Interpretation if needed.

Reporting to the client regarding the said situation and activities.

Page 3: UPDATED CV 2016

Responsible for performing quality inspection using the various NDT methods as applicable ( RT, UT FLAW, penetrant & magnetic particle testing).Responsibilities include processing, inspecting, & evaluating surface & subsurface discontinuities and accepting, rejecting, or reworking hardware in accordance with customer specifications.

EMPLOYMENT HISTORY:

Company : TUV RHEINLANDPosition : NDT INSPECTOR Industry : Oil and Gas Duration : Oct 25 – Dec. 15, 2015Location : Makati City, Philippines

PRIMARY FUNCTION:

PHILIPPINE COSTAL SUBIC BAY PORT.

SCOPE

INSPECTION AT UNDERGROUND TANK

REQUALIFICATION OF UNDERGROUND STORAGE TANK

VISUAL INSPECTION

ULTRASONIC TEST (UTG AND FLAW) CORROSION SCAN INSPECTION (back up for MFL machine)

UTG at the Top Shell, Manhole and all Tank Nozzle. Including Tank Collum using normal probe.

Page 4: UPDATED CV 2016

VISUAL INSPECTION AND RECOMMENDATION.

Responsible for performing quality inspection using the various NDT methods as applicable ( RT, UT FLAW, penetrant & magnetic particle testing).Responsibilities include processing, inspecting, & evaluating surface & subsurface discontinuities and accepting, rejecting, or reworking hardware in accordance with customer specifications.

PRINCIPLE DUTIES & RESPONSIBILITIES

Certificates products that is in conformance with customer specifications& maintains traceability to such certification as is applicable.

Creates NDT techniques Performs penetrant,x-ray, UT FLAW and magnetic particle inspection,vaccum test

& interprets results. Performs preventive maintenance and calibrations on NDT equipment. Operates vapor degreaser & performs the necessary process checks. Properly processes, sorts and verifies x-ray film Communicates closely with engineers on scarp, the works and process issues. Ensure paperwork is properly done Helps others area as needed.

Responsible for performing quality inspection using the various NDT methods as applicable ( RT, UT FLAW, penetrant & magnetic particle testing).Responsibilities include processing, inspecting, & evaluating surface & subsurface discontinuities and accepting, rejecting, or reworking hardware in accordance with customer specifications.

Page 5: UPDATED CV 2016

EMPLOYMENT HISTORY:

Company : R.I.M (former I.R.S) Position : NDT INSPECTOR Industry : Oil and Gas Duration : Sept 20 – Oct. 18, 2015Location : Makati City, Philippines

PRIMARY FUNCTION:

Requalification of Vertical Oil and Fuel Tank Storage Conduct UT Flaw at Vertical Tank in PETRON BATAAN REFINERY at Limay Bataan Philippines.

Conduct UTG (ULTRASONIC THICKNESS GAUGING And back up of UT FLAW DETECTION CORROSION SCAN using normal probe in every corrosion defect MFL (floor mapping) detect, at tank Bottom plates… Ultrasonic Thickness Gauging at Tank Shell Plate including Top Plates… Using EPOCH 4 UT Machine.Visual Inspection of Tank Shell Plate, Roof and Bottom Plate.

SCOPE INCLUDES,

VISUAL INSPECTION AND RECOMMENDATION.

Responsible for performing quality inspection using the various NDT methods as applicable ( RT, UT FLAW, penetrant & magnetic particle testing).Responsibilities include processing, inspecting, & evaluating surface & subsurface discontinuities and accepting, rejecting, or reworking hardware in accordance with customer specifications.

PRINCIPLE DUTIES & RESPONSIBILITIES Certificates products that is in conformance with customer specifications&

maintains traceability to such certification as is applicable. Creates NDT techniques Performs penetrant,x-ray, UT FLAW and magnetic particle inspection,vaccum test

& interprets results.

Page 6: UPDATED CV 2016

Performs preventive maintenance and calibrations on NDT equipment. Operates vapor degreaser & performs the necessary process checks. Properly processes, sorts and verifies x-ray film Communicates closely with engineers on scarp, the works and process issues. Ensure paperwork is properly done Helps others area as needed.

EMPLOYMENT HISTORY:

Company : ASIA CORROSION SERVICES, INC.Position : NDT Technician Level IIIndustry : Oil and Gas Duration : Jan 20, 2014 – Sept 15, 2015Location : Marikina City, PhilippinesManager : Rolando R. Ortanez

PRIMARY FUNCTION:

PHILIPPINE COSTAL STORAGE AND PIPELINE CORPORATION (SUBIC BAY FREEPORT ZONE)

Conduct Radiographic Test at 8ӯ CRFO Pipeline with thickness of 8.18mmIncluding film processing, Film Interpretation and reporting for the result of Radiographic test.

REBINTECH ENGINEERING SERVICES REQUALIFICATION OF 1000 USG LPG TANK AT PHILIPPINE BATTERY INC. (STA. MARIA BULACAN)

Ultrasonic THICKNESS Gauging of Shell and Head Plates including NozzlesDetailed Inspection report shall be submitted containing the CERTIFICATION, COMPUTATION, DRAWING, UTG RESULT, PHOTOS, VISUAL INSPECTION/RECOMMENDATION, TANK DATA and COVERING LETTER.

Page 7: UPDATED CV 2016

REQUALIFICATION OF 6 X 120 USG PIG TANKS PULLED OUT FROM MALLBERRY SUITES ( ILIGAN CITY )

Ultrasonic THICKNESS Gauging of Shell and Head Plates including NozzlesDetailed Inspection report shall be submitted containing the CERTIFICATION, COMPUTATION, DRAWING, UTG RESULT, PHOTOS, VISUAL INSPECTION/RECOMMENDATION, TANK DATA and COVERING LETTER.

PETRONAS ENERGY INC. ( ILIGAN CITY )

Requalification of 1500mt Spherical LPG tank. Conducting Ultrasonic Thickness Gauging of Sphere Top Crown Shell, Shell Plate and Bottom Plate.

Visual Inspection is the next to perform, Visual Inspected every bolt in flange at the Top Crown of the Sphere and Bottom Plate including the weldment and Sphere Coating.Doing Inspection Report of Sphere Ultrasonic Thickness Gauging and Visual Inspection such as CERTIFICATION, COMPUTATION, DRAWING, UTG RESULT, PHOTOS, VISUAL INSPECTION/RECOMMENDATION, TANK DATA and COVERING LETTER.

BOARDWALK VENTURES INC.Conduct Radiography test at Spiral weld in pipe wich will use at Hydrothermal wich have a Outside Diameter of 97.7mm diameter and 75mm diameter. Including film processing, Film Interpretation and reporting for the result of Radiographic test.

PHILIPPINE COSTAL STORAGE AND PIPELINE CORPORATION(POLE PIER SUBIC PHIL.)

Conduct Radiography test at 12ӯ x 12.7mm pipe which is oil line. Including film processing, Film Interpretation and reporting for the result of Radiographic test.

Page 8: UPDATED CV 2016

SEM CALACA POWER PLANT UNIT 1shutdown job(CALACA BATANGAS)

Conducting UT Thickness Gauging in water wall and every panel coil tube inside the boiler.Conducting Radiographic Test (RT) in every coil tube that are replace including in pent house.

2x 135 MW CFB POWER PLANT PROJECT(CALACA BATANGAS)

Conducting UT FLAW DETECTION at 2000mm Ø with the thickness of 16mm. including elbow and fittings at CIRCUMFERENTIALWATER PIPE (CWP)Also Dye Penetrant was conducted in every 24” Flange CWP Manhole

SLPGC 2x 150 MW CFB POWER PLANT PROJECT (PHASE 1)Client: D.M.C.I (CALACA BATANGAS)

Conducting UT FLAW DETECTION at 2000mm Ø with the thickness of 16mm. including elbow and fittings at WATER CIRCUMFERENTIAL PIPE (WCP) and FABYARD and FLUE LINER (CW and LW) at CHIMNEY. Conducting Radiographic Test (RT) at boiler tubes including film interpretation and RT report.Also Dye Penetrant was conducted in every 24” Flange CWP Manhole

Responsible for performing quality inspection using the various NDT methods as applicable ( RT, UT FLAW, penetrant & magnetic particle testing).Responsibilities include processing, inspecting, & evaluating surface & subsurface discontinuities and accepting, rejecting, or reworking hardware in accordance with customer specifications.

Page 9: UPDATED CV 2016

PRINCIPLE DUTIES & RESPONSIBILITIES Certificates products that is in conformance with customer specifications&

maintains traceability to such certification as is applicable. Creates NDT techniques Performs penetrant,x-ray, UT FLAW and magnetic particle inspection,vaccum test

& interprets results. Performs preventive maintenance and calibrations on NDT equipment. Operates vapor degreaser & performs the necessary process checks. Properly processes, sorts and verifies x-ray film Communicates closely with engineers on scarp, the works and process issues. Ensure paperwork is properly done Helps others area as needed.

EMPLOYMENT HISTORY:

Company : CIFRA INDUSTRIAL SERVICESPosition : NDT Technician Level IIIndustry : Oil and Gas Duration : 5 Sept.2013 - January 15,2014Location : Limay Bataan Philippines

PRIMARY FUNCTION:

PETRON (RMP-2) REFINERY MASTER PLAN 2(LIMAY BATAAN)

on going contruction under DAELIM PHIL.INC .maincontructor located at Limay Bataan Phil. Subcon by ARGUS NDT PWHT Services doing Line Check to Fabrication & site location to DEAH,SUNGDO,ILYANG & SEBO MEC.

Doing linecheck every afternoon in each fabrication & site location to the following client.

DEAH PHIL.SUNGDOILYANG SEBO MEC

Then conducting radiographic test in each joint with different pipe schedule that is listed in

Page 10: UPDATED CV 2016

every request given by each client everytime I conducting linecheck .After performing radiography at nightshift I collect all the films that each RT crew and doing developing until morning as a DARKROOM TECHNICIAN.

Responsible for performing quality inspection using the various NDT methods as applicable ( x-ray, penetrant & magnetic particle testing).Responsibilities include processing, inspecting, & evaluating surface & subsurface discontinuities and accepting, rejecting, or reworking hardware in accordance with customer specifications.

PRINCIPLE DUTIES & RESPONSIBILITIES

Certificates products that is in conformance with customer specifications& maintains traceability to such certification as is applicable.

Creates NDT techniques Performs penetrant,x-ray and magnetic particle inspection & interprets results. Performs preventive maintenance and calibrations on NDT equipment. Operates vapor degreaser & performs the necessary process checks. Properly processes, sorts and verifies x-ray film Communicates closely with engineers on scarp, the works and process issues. Ensure paperwork is properly done Helps others area as needed.

Company : STORK COOPERHEAT SAUDI ARABIA Co.Ltd.Position : NDT Technician Level IIIndustry : Oil and Gas Duration : 10 July 2008- 25 November 2011Location : Jubail City Kingdom of Saudi ArabiaManager : AshokanNelekandan

PRIMARY FUNCTION:

Page 11: UPDATED CV 2016

SHOIBA ( SAUDI ELECTRIC)

Conduct Radiography of different types of Fittings and Pipings and its Diameter such as 4ӯ, up to 30ӯ. Including Film Processing, Evaluation of Films and Reporting

QURAYYAH (SAUDI ELECTRIC)

Conduct Conventional Radiography (IRIDIUM 192) of different types of Fittings and Pipings and its Diameter, Including Film Processing, Evaluation of Films and Reporting

Conducting Radiography using SAFERAD a Radiography using SELINIUM 75

The radiation controlled areabarriers can be set at less than 1 metre awayfrom the radioactive source, even with source activities in excess of 80 Curies. Because radiography can be carried out without interfering with other operations it means that schedules can be maintained or improved and therefore huge savings can be made.The SAFER(Small Area For Exposure Radiography) radiography method has many potential benefits when compared to traditional radiography methods.

Conducting Radiographic using SAFERAD in diffrent pipe diameter including Film Processing, Interpretation and reporting.

Responsible for performing quality inspection using the various NDT methods as applicable ( x-ray, penetrant & magnetic particle testing).Responsibilities include processing, inspecting, & evaluating surface & subsurface discontinuities and accepting, rejecting, or reworking hardware in accordance with customer specifications.

AL-RASHID (ARCC) SHARQ PROJECT

Conducting Radiography using SAFERAD a Radiography using SELINIUM 75

Page 12: UPDATED CV 2016

The radiation controlled areabarriers can be set at less than 1 metre awayfrom the radioactive source, even with source activities in excess of 80 Curies. Because radiography can be carried out without interfering with other operations it means that schedules can be maintained or improved and therefore huge savings can be made.

The SAFER(Small Area For Exposure Radiography) radiography method has many potential benefits when compared to traditional radiography methods.

Conducting Radiographic using SAFERAD in diffrent pipe diameter including Film Processing, Interpretation and reporting.

PRINCIPLE DUTIES & RESPONSIBILITIES

Creates NDT techniques Performs penetrant,x-ray and magnetic particle inspection & interprets results. Performs preventive maintenance and calibrations on NDT equipment. Operates vapor degreaser & performs the necessary process checks. Properly processes, sorts and verifies x-ray film Communicates closely with engineers on scarp, the works and process issues. Ensure paperwork is properly done Helps others area as needed.

EMPLOYMENT HISTORY:

Company : Al MutawaSamyong NDT Co., LTD (AMSYCO)Position : NDT Technician Level IIIndustry : Oil and Gas Duration : 30 March 2007 - 28 May 2008Location : Jubail City Kingdom of Saudi ArabiaManager : AshokanNelekandan

Page 13: UPDATED CV 2016

PRIMARY FUNCTION:

Responsible for performing quality inspection using the various NDT methods as applicable ( x-ray, penetrant & magnetic particle testing).Responsibilities include processing, inspecting, & evaluating surface & subsurface discontinuities and accepting, rejecting, or reworking hardware in accordance with customer specifications.

PRINCIPLE DUTIES & RESPONSIBILITIES

Certificates products that is in conformance with customer specifications& maintains traceability to such certification as is applicable.

Creates NDT techniques Performs penetrant,x-ray and magnetic particle inspection & interprets results. Performs preventive maintenance and calibrations on NDT equipment. Operates vapor degreaser & performs the necessary process checks. Properly processes, sorts and verifies x-ray film Communicates closely with engineers on scarp, the works and process issues. Maintain lot integrity Ensure paperwork is properly done Helps others area as needed.

EMPLOYMENT HISTORY:

Company : CIFRA INDUSTRIAL SERVICESPosition : NDT Technician Level IIIndustry : Oil and GasDuration : 3 Sept.2006 - March 3 2007Location : Gen. Mojica St. Makati CityManager : De Leon

Job Description RT Technician Level II Film Developer/Film Interpreter Conducting R.T. of F2301, of F2302, F2303 Pipeline, of 4”Ø to 6”

to Furnace pipe interpret of radiographic film and inspection jo, for Petron Co. AlanganLimay, Bataan.Ultrasonic Gauging (UTG) testing of Pipe and plates thickness for metric Developing Film, film drying, arranging films, interprets film,

Page 14: UPDATED CV 2016

do tracing loading film into lead screen then to film jacket. R.T. and interpret convection tubes (Studded)) 6ӯ double wall single image (contact) R.T. and interpret radiant tubes (Studded) H-PIN, HOOP and Rise) 3ӯ, 4ӯ, 6ӯ, 18ӯ pipelines R.T. of 2ӯ schedule 80 double wall, double image elliptical stainless steel, Magnetic Particle Inspection (M.P.I.) of seam weld of spherical tank using cleaner remover magnetic, 7H-F magnetic particles using magnetic yolk permanent magnetic Penetrant Test (P.T.) O.D 14ӯ H-pin and white contrast paint.

Holiday Test (High voltage porosity detector) of oil transfer line.

Tools and Equipment Use

1. Iridium 1922. Selenium 75 (Saferad)3. Magnetic Yolk4. Cleaner Remover 5. Penetrant 6. Developer 7. Olympus EPOCH LT8. Agfa Film Viewer9. Densitometer10. TLD 11. Dose Guard

KEY QUALIFICATION

Has developed experience and expertise in Quality Assurance and Quality Control Inspection; Quality Inspection as per AWS D1.1, , ABS, ASTM, Corrosion Control, Testing and Evaluation, Nondestructive Testing of Weld and Materials, Tank Settlement and Bulges of Newly Erected Vertical Tank at Coastal Bay Chem. (Subic Bay Freeport Zone, P.O.L Pier)

WELL KNOWLEDGE IN CODE OF ACCEPTANCE SUCH AS

Page 15: UPDATED CV 2016

ABS (American Bureau of Shipping) ASME V (Non Destructive Testing)ASME B31.1 (Power Piping) ASME B31.3 (Process Piping) ASME B31.8 (Gas Transmission and Distribution Piping System) API 1104 (Welding of Pipelines and Related Facilities) AWS D1.1 (Structural Welding Code)

Radiographic Testing

Single Wall Exposure-Single wall Viewing (SWE/SWV) Double Wall Exposure-Single Wall Viewing (DWE/SWV) Double Wall Exposure-Double Wall Viewing (DWE/DWV) Film Interpretation

Dye Penetrant Testing Pre – Cleaning Penetrant Application Penetrant Dwell Time Removal of Excess Penetrant Developer Application Examination Evaluation

Requalification of Out of Service Tank As Per Code

Computation of, as follows MAWP (Maximum Allowable Working Pressure) MAT (Minimum Allowable Thickness) CR (Corrosion Rate) CA (Corrosion Allowance) RL (Remaining Life Years)

Page 16: UPDATED CV 2016

Ultrasonic Testing

All types of weld including T, K, Y Plotting of weld profile Straight Beam Scanning Technique Angle Beam Scanning Technique

Magnetic Particle Testing

Part Magnetization Technique Direction of Magnetic Field Magnetic Field Strength Application of Magnetic Particle Evaluation of Indication Demagnetization Post-Cleaning Examination

OTHER SKILLS

Computer Literate MS WORD and EXCEL POWER POINT,

STRENGTH

Can work under pressure Can work under minimal supervision Flexible and believes in teamwork Willing to work on shifting schedule

CHARACTER REFERENCES

CHRISTOPHER DC PAGTALUNAN+639192115516 NDT Inspector #34 South West Ipil St. Marikina Heights Marikina City

THOMAS MAGBANUA (02) 9486768 09175471949

Page 17: UPDATED CV 2016

ACSI Operations Manager #34 South West Ipil St. Marikina Heights Marikina City

TRAINING AND SEMINARS ATTENDED:

1. On the job Training on PT,RT,UT,MTCIFRA INDUSTRIAL SERVICES.Makati City, Philippines

2. H2S/B.A. TRAINING COURSEPilipinas Shell Petroleum Corporation (Tabangao Refinery)

3. Passed, Radiation Safety Examination conducted by Saudi ARAMCO.August 20, 2007

4. In House training and certification program RT and MTCertified ASNT Level II on RT and MT.AMSYCO NDT Co. Ltd.August 30, 2007

5. Received training and instruction in the use of the SAFERAD RADIOGRAPHY SYSTEM. (Reference MAP-17,001 Rev 05: Personnel Training Manual)

I hereby certify that above information are true and correct to the best of my knowledge and belief. Attached herewith my NDT Certification for your further information and evaluation.