university of sannio · multi-coil solenoids (2/2) when dealing with multi-coil solenoids, each...
TRANSCRIPT
![Page 1: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/1.jpg)
Luca De Vito
University of Sannio
MONITORING THE MAGNETIC AXIS
MISALIGNMENT IN PARTICLE
ACCELERATOR SOLENOIDS
![Page 2: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/2.jpg)
PROLOGUE
![Page 3: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/3.jpg)
EXTREME LIGHT INFRASTRUCTURE
Extreme Light Infrastructure (ELI) is a new Research Infrastructure of pan-European
interest and part of the European ESFRI Roadmap.
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
![Page 4: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/4.jpg)
ELI – NUCLEAR PHYSICS
The ELI Nuclear Physics (ELI-NP) facility
focuses on laser-based nuclear physics.
It will host two machines:
a very high intensity laser, where beams
from two 10 PW lasers are coherently
added to get intensities of the order of
1023 - 1024 W/cm2
a very intense, brilliant gamma beam, which
is obtained by incoherent Compton back
scattering of a laser light off a brilliant
electron beam from a conventional linear
accelerator.
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
Applications include nuclear physics experiments to characterize laser – target
interaction, photonuclear reactions, and exotic nuclear physics and astrophysics.
![Page 5: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/5.jpg)
ELI-NP SOLENOIDS
M1: photogun and electron beam extraction components (solenoid A)
M2: the first S–band accelerating structure and the solenoid B surrounding the S–band structure;
M3: the second S–band accelerating structure
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
![Page 6: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/6.jpg)
SOLENOIDS FOR BEAM FOCUSING
Solenoids are used for beam focusing.
They behave similarly to converging
glass lenses in optical microscopes.
In order to guarantee an accurate
focusing, the magnetic axis of the
magnet should be obtained with high
precision.
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
![Page 7: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/7.jpg)
MAGNETIC AXIS MONITORING
When a magnet is in operation, its coils are constantly subject to an
electrodynamic strain. The main reason resides in deformations caused by
thermal effects, despite a cooling system is usually installed. This could result in a
significant misalignment of the magnetic axis from the geometric axis.
The thermal effects are especially present at the magnet start-up, but the
misalignment can drift also during machine runnings, because of the heat
generated by particle beams.
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
An in-operation monitoring of the misalignment is needed
![Page 8: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/8.jpg)
MULTI-COIL SOLENOIDS
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
ELI-NP Solenoid B
Multi-coil solenoids with coaxial coils were studied for producing a uniform
magnetic field, or particular field configurations, e.g., a near-linear gradient axial
magnetic field.
The use of multi-coil solenoids as focusing structures is of great interest.
![Page 9: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/9.jpg)
MULTI-COIL SOLENOIDS (2/2)
When dealing with multi-coil solenoids, each coil may be affected by its peculiar
misalignment.
Hence, these misalignments have to be monitored when a strict constraint on
the coils alignment is required, thus allowing to adjust the coils position to
achieve/recover the solenoid design parameters.
In ELI-NP solenoids this can be done with adjustable screws to translate and/or
rotate a single coil, even during its operation, with a precision of tens of
micrometers.
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
![Page 10: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/10.jpg)
THE CHALLENGE
![Page 11: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/11.jpg)
ELI-NP MAGNETIC AXIS
MONITORING SPECIFICATIONS
Multi coil solenoid are made by a magnetic yoke that can be imagined as a
cylinder 3 m long with a diameter of 60-80 cm and 12 or more coils grouped in
three or more sets, individually powered and installed inside the yoke.
The challenge is to put the resulting magnetic axis inside an ideal cylinder with
radius ±5 microns, have the capability to check the magnetic axis precision and if
necessary adjust each coil position to achieve/recover the design parameters.
Very hard specs:
we need to measure field difference with very high accuracy
field difference in solenoids is very small
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
![Page 12: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/12.jpg)
WHAT SHOULD WE
DO AT THIS STAGE?
![Page 13: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/13.jpg)
… STUDYING
![Page 14: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/14.jpg)
…BUT ALSO MEETING EXPERIENCED
PEOPLE
![Page 15: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/15.jpg)
METHODS FOR THE MAGNETIC AXIS
MEASUREMENT
Current method for magnetic axis determination:
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
Stretched wire Vibrating wireHall probe mapper
![Page 16: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/16.jpg)
HALL PROBE MAPPER
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
K. H. Park, Y. K. Jung, D.E. Kim, H.G. Lee, S.J. Park, C.W. Chung, B.K. Kang, “Field Mapping System for Solenoid
Magnet”, AIP Conference Proceedings, vol. 879, no. 1, pp. 260–263, 2007.
![Page 17: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/17.jpg)
STRETCHED WIRE
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
J. Di Marco, H. Glass, M. J. Lamm, P. Schlabach, C. Sylvester, J.C. Tornpkins, “Field alignment of quadrupole
magnets for the LHC interaction regions”, IEEE Transactions on Applied Superconductivity, 2000
z1
z2
![Page 18: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/18.jpg)
VIBRATING WIRE (1/2)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
Feeding a conducting wire by a sinusoidal current
Magnetic field longitudinal components
Wire oscillation amplitude
Lorentz force
P. Arpaia, C. Petrone, S. Russenschuck, L. Walckiers, “Measuring field multipoles in accelerator magnets with
small-apertures by an oscillating wire moved on a circular trajectory”, Journal of Instrumentation, 2012
![Page 19: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/19.jpg)
VIBRATING WIRE (2/2)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
![Page 20: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/20.jpg)
APERTURE NOT ACCESSIBLE!
Methods actually used for magnet
alignment cannot ne used for in-
operation monitoring.
When in operation, most part of the
solenoid aperture (in particular near
the magnetic axis) is obstructed by
the beam pipe and other equipment.
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
![Page 21: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/21.jpg)
BRAIN STORMING (1/3)
Idea 1: To use multiple (3 or 4) vibrating wires.
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
PRO: Sensitivity (Significant vibrations also with low field)
CONS: Hard to obtain several wires with identical mechanical behavior.
![Page 22: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/22.jpg)
BRAIN STORMING (2/3)
PRO: Easy to build, high accuracy.
CONS: Require field gradient. Static coils can be only in the case of pulsed magnets (NOT the case of ELI-NP!). Not enough space for rotating/translating coils.
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
Idea 2: To use coils.
![Page 23: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/23.jpg)
BRAIN STORMING (3/3)
Idea 3: To use several Hall transducers
(thanks to Carlo Petrone for the discussion!)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
PROS: Measuring directly the magnetic field, small, no motion.
CONS: Lower accuracy, possibly damaged by radiation (monitoring during
working).
![Page 24: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/24.jpg)
RADIATION RESISTANCE FOR ELI-NP
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
![Page 25: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/25.jpg)
WE KNOW NOW ENOUGH
TO START WORKING
![Page 26: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/26.jpg)
LET’S GO WITH HALL TRANSDUCERS! (1/2)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
4 Hall transducers on two planes
perpendicular to the mechanical
axis;
Due to the axisymmetry of the
field, in the aligned case, the Hall
transducers would measure the
same field magnitude.
![Page 27: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/27.jpg)
LET’S GO WITH HALL TRANSDUCERS! (2/2)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
If misaligned, the Hall
transducers will not measure the
same magnitude.
The method aims to derive the
equation of the misaligned axis
from the Hall transducer
measurements.
![Page 28: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/28.jpg)
METHOD DEFINITION (1/4)
Description of the magnetic axis:
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
2 1' ' 'P t O t O O
'
'
O x
O y
x x v t
y y v t
z t d
2 1
2 1
' '
' '
x O O
y O O
v x x
v y y
Assumption of no longitudinal shift:
0'O
![Page 29: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/29.jpg)
METHOD DEFINITION (2/4)
Under the assumption of a small misalignment:
0 0
0 0
, ,
' , ' , ' '
h h
hk hk h hk hk h
R z R z
B BB r z B R z r R z z
r z
' ' 0, , ,O O x yx y v v R
Magnetic axis
Transducer
positionMisaligned
transducer
position
11H 11'HField
magnitude
Radial position
of the tranducer
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
![Page 30: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/30.jpg)
METHOD DEFINITION (3/4)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
2 22
11 1 0 1 1 1 0 1' I I I Ir x R y z z R y
1111 1
1'
2Iz z t d
11 11
11 11
11 11
'
'
I O I x
I O I y
I I
x x t v
y y t v
z t d
11 11 11 11' '2
1I x H O y H O Ht v x x v y y d z
d
I11 belongs to the
magnetic axis
![Page 31: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/31.jpg)
METHOD DEFINITION (4/4)
Repeating for all probes…
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
0 0
0 0
0 0
0
013 11 '
, /2 , /2
014 12 '
, /2 , /2
023 21 '
, /2 , /2
024 22 '
, /2
12 2
2
12 2
2
12 2
2
12 2
2
O y y
R d R d
O x x
R d R d
O y y
R d R d
O x
R d
RB BB H B H y v v
r d z
RB BB H B H x v v
r d z
RB BB H B H y v v
r d z
RBB H B H x v
r d
0 , /2
x
R d
Bv
z
We need:
Measured field magnitude
values (from triaxial Hall
transducers)
Derivatives of the field
magnitude in the aligned
case (from solenoid mapping
or FEM)
P. Arpaia, B. Celano, L. De Vito, A. Esposito, N. Moccaldi, and A. Parrella, “Monitoring the magnetic
axis misalignment in axially-symmetric magnets,” in Proc. of 2018 Int. Instrum. and Meas. Tech. Conf.,
2018, pp. 1726–1731.
![Page 32: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/32.jpg)
SOLENOID ANALYTICAL MODEL
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
N. Derby, S. Olbert, “Cylindrical magnets and ideal solenoids”, American Journal of Physics, vol.
78, 2010
![Page 33: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/33.jpg)
UNIAXIAL TRANSDUCERS VS.
TRIAXIAL TRANSDUCERS
In order to evaluate the magnetic field magnitude we need 3D Hall transducers.
However, 1D Hall transducers show a better accuracy than the 3D ones
Can we modify the method to work with 1D sensors?
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
![Page 34: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/34.jpg)
USING UNIAXIAL PROBES (1/7)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
0 0
0 0
, ,
' , ' , ' '
h h
hk hk h hk hk h
R z R z
r z R z r R z zr z
B BB B
Expansion of
the B vector
sinm mr mz r zB B B B B
2 211 13
1 112 14
sin sin
sin sin
v v
d d
v v
d d
0 0
0 0
0 0
, ,
0 0
, ,
' , ' , ' '
' , ' , ' '
h h
h h
r rr hk hk r h hk hk h
R z R z
z zz hk hk z h hk hk h
R z R z
B BB r z B R z r R z z
r z
B BB r z B R z r R z z
r z
Uniaxial probe
measurement
![Page 35: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/35.jpg)
USING UNIAXIAL PROBES (2/7)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
![Page 36: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/36.jpg)
EXPLOITING FIELD SYMMETRIES
IN THE ALIGNED CASE
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
![Page 37: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/37.jpg)
USING UNIAXIAL PROBES (3/7)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
![Page 38: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/38.jpg)
USING UNIAXIAL PROBES (4/7)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
Transducers placed along the radial direction:
P. Arpaia, B. Celano, L. De Vito, A. Esposito, A. Parrella, and A. Vannozzi, “Measuring the
magnetic axis alignment during solenoids working,” Nature Scientific Reports, no. 8,
2018.
![Page 39: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/39.jpg)
USING UNIAXIAL PROBES (5/7)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
Transducers placed along the radial direction:
![Page 40: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/40.jpg)
USING UNIAXIAL PROBES (6/7)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
Transducers placed along the axial direction:
P. Arpaia, B. Celano, L. De Vito, A. Esposito, A. Parrella, and A. Vannozzi, “Measuring the
magnetic axis alignment during solenoids working,” Nature Scientific Reports, no. 8,
2018.
![Page 41: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/41.jpg)
USING UNIAXIAL PROBES (7/7)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
Transducers placed along the axial direction:
![Page 42: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/42.jpg)
FEM EVALUATION
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
We would like to evaluate the derivates and the field in the aligned case by FEM
and not only by the analytical model.
The FeM of the ELI-NP SolenoidB was evaluated (multicoil)
The result of the FEM wscompared with the experimentaldata from the magnetcharacterization (by the manufacturer)
The actual FEM used wasobtained then by simulating a single active coil.
![Page 43: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/43.jpg)
METHOD CONFIGURATION
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
Where to place the Hall probes? Positions minimizing uncertainty
Considered uncertainty sources:
Measurement uncertainty of the Hall transducers (uB)
Uncertainty related to the transducers placing (ug)
Uncertainty of the derivatives of Br (u∂)
Uncertainty of the Bz0 value (uf)
![Page 44: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/44.jpg)
UNCERTAINTY EVALUATION (1/3)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
![Page 45: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/45.jpg)
UNCERTAINTY EVALUATION (2/3)
Considering the order of magnitude of the uncertainties:
uB ≈ 10-4 T typical uncertainty of uniaxial Hall transducers
ug ≈ 10-5 m placement by laser tracker
u∂ ≈ 10-2 T/m, uf ≈ 10-3 T, field model accuracy 1%
In the case of the ELI-NP solenoid, only uB and u∂ give significant contribution:
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
![Page 46: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/46.jpg)
UNCERTAINTY EVALUATION (3/3)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
Minima are located for R0/R close to 1 and d ≈ 0.9L
Analytical model FEM (one coil)
Uncertainty is slightly more than 50 μm
![Page 47: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/47.jpg)
3 TRANSDUCERS PER SIDE (1/3)
In some cases, only 3 positions per side are accessible for probe positioning.
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
![Page 48: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/48.jpg)
3 TRANSDUCERS PER SIDE (2/3)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
Transducers placed along the radial direction:
![Page 49: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/49.jpg)
3 TRANSDUCERS PER SIDE (3/3)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
![Page 50: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/50.jpg)
UNCERTAINTY FOR 3 TRANSDUCERS
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
![Page 51: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/51.jpg)
UNCERTAINTY FOR 3 TRANSDUCERS
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
Analytical model FEM
Minima are again located for R0/R close to 1 and d ≈ 0.9L
Uncertainty of the vertical coordinate is doubled to about 100 μm
![Page 52: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/52.jpg)
WHAT ABOUT MULTI-COIL
SOLENOIDS?
![Page 53: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/53.jpg)
MULTI-COIL SOLENOIDS
For a single cylindrical coil, assuming that the magnetic field is axially symmetric, the
magnetic axis is a straight line and coincides with the symmetry axis of the magnetic
field.
Even assuming the magnetic field of each coil as axially symmetric, the actual
misalignments of such fields make the overall magnetic field not axially symmetric.
We approximate approximated it with a polygonal chain, composed by as many
segments as the number of the coils, where each segment is part of the magnetic axis
of the corresponding coil.
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
![Page 54: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/54.jpg)
EXTENSION TO MULTI-COIL SOLENOIDS (1/4)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
![Page 55: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/55.jpg)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
EXTENSION TO MULTI-COIL SOLENOIDS (2/4)
![Page 56: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/56.jpg)
EXTENSION TO MULTI-COIL SOLENOIDS (3/4)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
P. Arpaia, L. De Vito, A. Esposito, A. Parrella, and A. Vannozzi, “On-field monitoring of the
magnetic axis misalignment in multi-coils solenoids,” Journal of Instrumentation, vol. 13,
2018.
![Page 57: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/57.jpg)
EXTENSION TO MULTI-COIL SOLENOIDS (4/4)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
![Page 58: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/58.jpg)
MAGNETIC FIELD SIMULATION (1/2)
Differences are due to the magnetic shield that in solenoids is often employed to limit
fringe flux, and to reduce the number of ampere-turns for a given focal length.
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
Analytical model
(overposition of the single coil fields) FEM
![Page 59: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/59.jpg)
MAGNETIC FIELD SIMULATION (2/2)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
Analytical model
Radial
Longitudinal
FEM without shield
![Page 60: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/60.jpg)
UNCERTAINTY EVALUATION (1/2)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
A closed form of the uncertainty is difficult to obtain in this case.
![Page 61: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/61.jpg)
UNCERTAINTY EVALUATION (2/2)
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
The optimal placing of the N planes couples is approximatively the same for all the N coils.
It corresponds to R0 equal about to the 90% of the aperture, and d equal to about 75% of
the coil length L
![Page 62: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/62.jpg)
STILL TO DO…
![Page 63: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/63.jpg)
PLANNED EXPERIMENTAL EVALUATION
To carry experimental tests:
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
@ CERN
on LINAC4 Low Energy Beam Transport
(LEBT) (single coil) Solenoid
@ INFN / LNF
on SPARC focusing solenoid (multi-
coil, similar to the ELI-NP one)
![Page 64: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/64.jpg)
CONCLUSION
I presented a problem of designing a monitoring method for the magnetic axis
misalignment in solenoids.
Measurement specifications were very challenging and current method for
magnetic axis determination were not suitable due to the inaccessibility of the
magnet aperture.
We designed a new method based on several Hall transducers placed on two
planes orthogonal to the nominal axis of the solenoid (of each coil in the multi-
coil case).
We carried out an uncertainly analysis of the method.
We are now going to realize the experimental evaluation of the method.
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
![Page 65: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/65.jpg)
PROJECT TEAM
Pasquale Arpaia
University of Naples
Federico II
Luca De Vito
University of Sannio
Alessandro Parrella
University of Lisbon
and CERN
Antonio Esposito,
University of Naples
Federico II
Alessandro Vannozzi
INFN / LNFNicola Moccaldi
University of Naples
Federico II
Biase Celano
University of Naples
Federico II
![Page 66: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/66.jpg)
BUT ALSO THANKS TO…
Carlo Petrone, CERN
Stephan Russenschuck, CERN
Sandro Tomassini, INFN
Oscar Frascione, INFN
LUCA DE VITO - MONITORING THE MAGNETIC AXIS MISALIGNMENT IN PARTICLE ACCELERATOR SOLENOIDS
![Page 67: University of Sannio · MULTI-COIL SOLENOIDS (2/2) When dealing with multi-coil solenoids, each coil may be affected by its peculiar misalignment. Hence, these misalignments have](https://reader036.vdocuments.mx/reader036/viewer/2022062602/5eba70ad3d757c05d9451f4b/html5/thumbnails/67.jpg)
Luca De VitoLaboratorio di Elaborazione dei Segnali e
delle Informazioni di Misura
Dipartimento di Ingegneria
Università degli Studi del Sannio