universal furnace electronic fan timer - emerson us · 2019-10-21 · universal furnace electronic...

2
Universal Furnace Electronic Fan Timer 50F06-843 A universal solution that is easy to install, configure, and diagnose Universal Replacement Replaces over 150 OEM and competitive part numbers Works with SmartValve™ systems and other non-integrated modules * A registered trademark of Honeywell Inc. Advanced Diagnostics Tri-Color LED displays status and fault codes Exclusive fault recall button Easy Installation Six mounting hole options Harnesses with terminal flags for easy wiring Terminals are labeled to match multiple existing boards Transformer connections offer 1/4" and 3/16" terminals

Upload: others

Post on 15-Jul-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Universal Furnace Electronic Fan Timer - Emerson US · 2019-10-21 · Universal Furnace Electronic Fan Timer 50F06-843 A universal solution that is easy to install, configure, and

Universal Furnace Electronic Fan Timer50F06-843

A universal solution that is easy to install, configure, and diagnose

Universal Replacement

Replaces over 150 OEM and competitive part numbers

Works with SmartValve™ systems and other non-integrated modules* A registered trademark of Honeywell Inc.

Advanced Diagnostics

Tri-Color LED displays status and fault codes

Exclusive fault recall button

Easy Installation

Six mounting hole options

Harnesses with terminal flags for easy wiring

Terminals are labeled to match multiple existing boards

Transformer connections offer 1/4" and 3/16" terminals

Page 2: Universal Furnace Electronic Fan Timer - Emerson US · 2019-10-21 · Universal Furnace Electronic Fan Timer 50F06-843 A universal solution that is easy to install, configure, and

R-4968 (9/19)

COMPETITIVE COMPARISONFEATURES WHITE-RODGERS - 50F06-843 BRAND X

Board Cross-References 150+ 48

Standard Mounting Options 2 1

24v Transformer 1/4” Spade Extension Wires Included

Terminal label ID’s cover multiple board versions

Harnesses with terminal flags for easy wiring

Heating & Cooling fan can be operated on single speed (ACC output)

Fan Only (G) can be set to Heating or Cooling speed

1/4" & 3/16" 24v Transformer Connections

Unused Motor / Park Terminals 3 2

Tri-color LED display Green/Amber/Red Green Only

Tri-color LED displays Heat/Cool/Fan status

Fault code label

Fault recall & clearing Simple Push Button None

SPECIFICATIONSElectrical Ratings:Input Low Voltage: 25 VAC 60 HzInput Line Voltage: 115/230 VAC 60 HzMax Input Current: 800mA @ 25 VAC

Operating Temperature Range:-40° to 176° F (-40° to 80° C)Dimensions:5.0" W x 7.0" L x 1.50" D

1 Year Limited Warranty

HoneywellST9101A1006ST9101A1014ST9101A1022ST9120A1006 ST9120A2004ST9120B1005ST9120C1012ST9120C1020ST9120C2002ST9120C2010ST9120C2028ST9120C3000ST9120C3018ST9120C4008ST9120C4016ST9120C4040ST9120C4057ST9120C5005 ST9120C5013 ST9120D3009ST9120G2008ST9120G2016ST9120G2024ST9120G2032ST9120G4004

ST9120G4012ST9120G4038ST9120U1003ST9120U1011ST9141A1002 ST9141A1028ST9141B1001ST9150A1003ST9150B2000 ST9150B2018ST9150B2026ST9150B2034ST9160A1002ST9160B1001ST9160B1019ST9160B1027ST9160B1035ST9160B1043ST9160B1050ST9160B1068ST9160B1076ST9160B1084ST9160C1000 ST9160C1018

Carrier/BryantCAR20054502

Consolidated Ind.406650

Goodman/Amana/JanitrolB180911B18099-11B1809911S CARB1809911CARL38267

ICMICM270AC1015

Lennox/Armstrong/Ducane/Excel45392-00120054501200545022043081204308014040300140403-00140403002

40403-0024040300340403-00345392001456920013849380011138-1001138-83-1002A28M90128M9928M9901384938-001400B009145692-00187H8887H8801 R40403001R40403-001R40403002R40403-002R40403003R40403-003R45392001R45392-001R45692001R45692-001X8609X860901

Rheem/RUUD Brands47-22693-0147-22693-0247-22827-0147-22827-0247-22827-0347-22827-8147-22827-8247-22827-8347-22828-0147-22828-0247-22830-0147-22830-02

Robertshaw 695-003

ICP/Arcoaire/Comfortmaker/Heil/Tempstar 100877310087861009836100983710098381010031

CROSS REFERENCE10111791011543101192710121061012358101446010841971150489116019211700631138-83-200A1138-200HQ1008773HWHQ1008786HWHQ1009836HWHQ1009837HWHQ1009838HWHQ1010031HWHQ1011179HWHQ1011543HWHQ1011927HWHQ1012106HWHQ1012358HWHQ1084197HWHQ1170063HW

JCI/York/Coleman/Evcon 2702-3002702-300P3101237000310295900033101237000025-32816-000026-32254-000026-34030-000031-01237-000031-02959-0001138-1032895-3001331-01237-000S1-02532816000S1-0263403000S1-03101237000S1-031-01237-000S1-03102959000S1-031-02959-000S1-2702-300PS1-33101237000S1-331-01237-000

Weil-McLain4116000

©2019 Emerson Electric Co. • White-Rodgers and Emerson are trademarks of Emerson Electric Co. All rights reserved • Customer Service or Technical Help: 888-725-9797 • Emerson.com/White-Rodgers

50F06-843 - For single stage furnaces with PSC inducer and blower motors

TIMING SPECIFICATIONS

All times are in seconds unless noted otherwise

Postpurge

Lockout time

Heat ON

delay

Heat OFF

delay

Cool ON

delay

Cool OFF

delay

5 60 min 30*, 6060,120*,150, 180

4*, 30 30*, 60

* Default dipswitch settings