unique firestop products: threaded sleeve fire stop system
TRANSCRIPT
![Page 1: Unique Firestop Products: Threaded Sleeve Fire Stop System](https://reader034.vdocuments.mx/reader034/viewer/2022051318/5876503f1a28ab0d198b69ab/html5/thumbnails/1.jpg)
Threaded Firestop Sleeve
System Installation
![Page 2: Unique Firestop Products: Threaded Sleeve Fire Stop System](https://reader034.vdocuments.mx/reader034/viewer/2022051318/5876503f1a28ab0d198b69ab/html5/thumbnails/2.jpg)
UNIQUE Threaded Firestop Sleeve
System is designed for new cable
installations where the hole through
the firewall or floor is core bored or
precut.
![Page 3: Unique Firestop Products: Threaded Sleeve Fire Stop System](https://reader034.vdocuments.mx/reader034/viewer/2022051318/5876503f1a28ab0d198b69ab/html5/thumbnails/3.jpg)
The Threaded Firestop Sleeve is
constructed of rigid steel tubing that
is threaded on both ends and made of
(IMC) Intermediate Metal Conduit.
![Page 4: Unique Firestop Products: Threaded Sleeve Fire Stop System](https://reader034.vdocuments.mx/reader034/viewer/2022051318/5876503f1a28ab0d198b69ab/html5/thumbnails/4.jpg)
The system includes:
1 – 12″ threaded IMC sleeve
2 – large flat washers
2 – threaded couplings
2 – plenum rated bushings
2 – documentation/warning labels
1 – A package of UNIQUE Intumescent Putty
![Page 5: Unique Firestop Products: Threaded Sleeve Fire Stop System](https://reader034.vdocuments.mx/reader034/viewer/2022051318/5876503f1a28ab0d198b69ab/html5/thumbnails/5.jpg)
Threaded Firestop Sleeves come in
4” inches, 2”, and 1" diameters.
![Page 6: Unique Firestop Products: Threaded Sleeve Fire Stop System](https://reader034.vdocuments.mx/reader034/viewer/2022051318/5876503f1a28ab0d198b69ab/html5/thumbnails/6.jpg)
INSTALLATION PICTORIAL
![Page 7: Unique Firestop Products: Threaded Sleeve Fire Stop System](https://reader034.vdocuments.mx/reader034/viewer/2022051318/5876503f1a28ab0d198b69ab/html5/thumbnails/7.jpg)
A 4 inch System will require a 4 & 1/2 inch hole
minimum! Most people should drill a 5 inch
hole for the 4 inch Threaded Sleeve.
Pre-drill the hole in
advance. BE SURE to
drill the hole to the
outside diameter
(O.D.) of the System
you will be using.
![Page 8: Unique Firestop Products: Threaded Sleeve Fire Stop System](https://reader034.vdocuments.mx/reader034/viewer/2022051318/5876503f1a28ab0d198b69ab/html5/thumbnails/8.jpg)
Remove the documentation warning label.
![Page 9: Unique Firestop Products: Threaded Sleeve Fire Stop System](https://reader034.vdocuments.mx/reader034/viewer/2022051318/5876503f1a28ab0d198b69ab/html5/thumbnails/9.jpg)
Disassemble one side of the System.
Adjust the
coupling, washer
and bushing so
that the sleeve will
protrude evenly on
both sides when
installed.
![Page 10: Unique Firestop Products: Threaded Sleeve Fire Stop System](https://reader034.vdocuments.mx/reader034/viewer/2022051318/5876503f1a28ab0d198b69ab/html5/thumbnails/10.jpg)
Feed the System into the hole you have pre-
drilled. Go below and install the other half of
the hardware.
![Page 11: Unique Firestop Products: Threaded Sleeve Fire Stop System](https://reader034.vdocuments.mx/reader034/viewer/2022051318/5876503f1a28ab0d198b69ab/html5/thumbnails/11.jpg)
The vertical
application of the
Threaded Sleeve
requires the sleeve
to be packed (3 inch
depth) with mineral
wool batt insulation.
This keeps gravity from having any effect on
the intumescent putty.
![Page 12: Unique Firestop Products: Threaded Sleeve Fire Stop System](https://reader034.vdocuments.mx/reader034/viewer/2022051318/5876503f1a28ab0d198b69ab/html5/thumbnails/12.jpg)
If used horizontally, this system needs
no wool batt.
![Page 13: Unique Firestop Products: Threaded Sleeve Fire Stop System](https://reader034.vdocuments.mx/reader034/viewer/2022051318/5876503f1a28ab0d198b69ab/html5/thumbnails/13.jpg)
When the cables
reach their
destination, install a
minimum 1/2 inch
thickness of Unique
Putty per the vertical
application.
This System used horizontally, needs a
minimum 1 inch thickness of putty.
![Page 14: Unique Firestop Products: Threaded Sleeve Fire Stop System](https://reader034.vdocuments.mx/reader034/viewer/2022051318/5876503f1a28ab0d198b69ab/html5/thumbnails/14.jpg)
Fill out and attach the documentation/warning
label.
![Page 15: Unique Firestop Products: Threaded Sleeve Fire Stop System](https://reader034.vdocuments.mx/reader034/viewer/2022051318/5876503f1a28ab0d198b69ab/html5/thumbnails/15.jpg)
Don’t forget to take a
picture of your completed
installation for future
reference.
![Page 16: Unique Firestop Products: Threaded Sleeve Fire Stop System](https://reader034.vdocuments.mx/reader034/viewer/2022051318/5876503f1a28ab0d198b69ab/html5/thumbnails/16.jpg)
Visit our website for more firestop products
and complete installation pictorials.
https://www.uniquefirestop.com/