unilux corporate sales brochure - outlines · unilux corporate sales brochure - outlines.indd...

8

Upload: others

Post on 06-Jun-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Unilux Corporate Sales Brochure - OUTLINES · Unilux Corporate Sales Brochure - OUTLINES.indd Created Date: 11/1/2018 10:12:08 AM
Page 2: Unilux Corporate Sales Brochure - OUTLINES · Unilux Corporate Sales Brochure - OUTLINES.indd Created Date: 11/1/2018 10:12:08 AM
Page 3: Unilux Corporate Sales Brochure - OUTLINES · Unilux Corporate Sales Brochure - OUTLINES.indd Created Date: 11/1/2018 10:12:08 AM

Boiler Water Chiller

1st-Floor Apartment

Main Floor

2nd-Floor Apartment

3rd-Floor Apartment

Page 4: Unilux Corporate Sales Brochure - OUTLINES · Unilux Corporate Sales Brochure - OUTLINES.indd Created Date: 11/1/2018 10:12:08 AM

VFC options• 2-pipe, 2-pipe with

auxiliary heat & 4-pipe configurations

• Integrated ERV/HRV

• Wi-Fi-enabled control

Vertical fan coil configuration

Vertical Stack Fan Coils Use vertical stack fan coils (VFCs) for heating and cooling suites in condos, hotels, apartments and more. VFCs allow individual suites to have complete control over their comfort. We manufacture VFCs in many configurations to suit your development’s requirements.

Email [email protected] for more information on our lineup of VFCs.

Supply and return risers

Hinged & removable access panel

EPDM formed P-trap drain hose

Return air opening

Forward-curved blower

Motorized control valve

Isolating ball valve

Thermally protected multi-speed ECM motor

Satin-coat steel cabinet with acoustical insulation

Coil: ½” O.D. copper tubes

1-Piece stainless-steel drain pan (insulated)

Acoustical baffle

ETL tested and approved for Electrical Safety Compliance

3

Page 5: Unilux Corporate Sales Brochure - OUTLINES · Unilux Corporate Sales Brochure - OUTLINES.indd Created Date: 11/1/2018 10:12:08 AM

Integrated Vertical Stack Fan Coils Our integrated VFCs have a heat recovery ventilator (HRV) or energy recovery ventilator (ERV) built right into the cabinet. Recovery ventilators bring fresh, outside air into the suite. The fresh outside air passes through a membrane with the indoor exhaust air on the other side. The heat and moisture are transferred to the fresh air – reducing energy costs to treat the fresh air.

Add an HRV or ERV to your VFC –

email [email protected].

Supply and return risers

Hinged & removable access panel

Return air opening

Forward-curved blower

Motorized control valve

Isolating ball valve

Acoustical baffle

ETL tested and approved for Electrical Safety Compliance

4

Spring return freeze protection damper

18-gauge galvanized steel drain pan

AHRI certified ERV/HRV core

ERV Core

HRV Core

Page 6: Unilux Corporate Sales Brochure - OUTLINES · Unilux Corporate Sales Brochure - OUTLINES.indd Created Date: 11/1/2018 10:12:08 AM

Anti-FreezeTemperature

Sensor

Drain-Pan Overflow Sensor

Page 7: Unilux Corporate Sales Brochure - OUTLINES · Unilux Corporate Sales Brochure - OUTLINES.indd Created Date: 11/1/2018 10:12:08 AM

21 8/

HFC options• 2-Pipe & 4-Pipe configurations

DX Hybrid Vertical Fan Coil NEW

• Standard 2-pipe system features plus:

• Refrigerated charged coil: ½" O.D. copper tubes

• Paired with a condensing unit located on a balcony or roof

6